{"id":13798,"date":"2023-04-11T16:24:17","date_gmt":"2023-04-11T07:24:17","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13798"},"modified":"2025-02-07T16:02:02","modified_gmt":"2025-02-07T07:02:02","slug":"foreign_material_ft-ir_msd_sales10","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/","title":{"rendered":"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1"},"content":{"rendered":"<p>\u6a39\u8102\u306a\u3069\u306e\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u306f\u69d8\u3005\u306a\u8981\u56e0\u3067\u8d77\u3053\u308a\u3001\u7d2b\u5916\u7dda\u306f\u305d\u306e\u8981\u56e0\u306e\u6700\u305f\u308b\u3082\u306e\u306b\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u7d2b\u5916\u7dda\u306b\u3088\u308b\u52a3\u5316\u304c\u9032\u3080\u969b\u3001\u74b0\u5883\u306e\u9055\u3044\u304c\u52a3\u5316\u306e\u9032\u884c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u53ca\u307c\u3059\u306e\u304b\u3092\u8abf\u3079\u308b\u305f\u3081\u3001\u7d2b\u5916\u7dda\u3092\u7167\u5c04\u3057\u5f37\u5236\u7684\u306b\u52a3\u5316\u3092\u9032\u884c\u3055\u305b\u305f\u6a39\u8102\u306b\u3064\u3044\u3066FT-IR\u3092\u7528\u3044\u305f\u5206\u6790\u3092\u8a66\u307f\u307e\u3057\u305f\u3002<\/p>\n<h2>\u5b9f\u9a13<\/h2>\n<p>\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\uff08PE\uff09\u677f\u3092\u7528\u3044\u307e\u3057\u305f\u3002UV\u7167\u5c04\u88c5\u7f6e\u3092\u7528\u3044\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u677f\u306b\u7d2b\u5916\u7dda\u3092\u7d2f\u8a088\u6642\u9593\u7167\u5c04\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u969b\u3001UV\u7167\u5c04\u6761\u4ef6\u3068\u3057\u3066\u3001\u300c\u2460 \u5927\u6c17\uff08\u305d\u306e\u307e\u307e\u306e\u72b6\u614b\uff09\u300d\u3001\u300c\u2461 \u5927\u6c17\uff0b\u6c34\uff08\u30b5\u30f3\u30d7\u30eb\u8868\u9762\u306b\u6c34\u3092\u6ef4\u4e0b\u3057\u305f\u72b6\u614b\uff09\u300d\u3001\u300c\u2462 \u30ab\u30d0\u30fc\u30ac\u30e9\u30b9\uff08\u30ab\u30d0\u30fc\u30ac\u30e9\u30b9\u3092UV\u7167\u5c04\u9762\u306b\u304b\u3076\u305b\u305f\u72b6\u614b\uff09\u300d\u306e3\u7a2e\u985e\u306e\u6761\u4ef6\u3092\u8a2d\u5b9a\u3057\u307e\u3057\u305f\u3002\u56f31\u306b\u5404\u6761\u4ef6\u306e\u6982\u7565\u56f3\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13804\" style=\"width: 677px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13804\" class=\"size-full wp-image-13804\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png\" alt=\"UV\u7167\u5c04\u6761\u4ef6\u306e\u6982\u7565\u56f3\" width=\"667\" height=\"246\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png 667w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01-300x111.png 300w\" sizes=\"auto, (max-width: 667px) 100vw, 667px\" \/><p id=\"caption-attachment-13804\" class=\"wp-caption-text\">\u56f31\uff1aUV\u7167\u5c04\u6761\u4ef6\u306e\u6982\u7565\u56f3<\/p><\/div>\n<p>30\u5206\u6bce\u306b\u4e00\u65e6\u7167\u5c04\u3092\u4e2d\u65ad\u3057FT-IR\u306b\u3088\u308bUV\u7167\u5c04\u9762\u306eATR\u6e2c\u5b9a\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u6e2c\u5b9a\u5f8c\u518d\u5ea6\u7167\u5c04\u3092\u518d\u958b\u3057\u8a088\u6642\u9593\u306eUV\u7167\u5c04\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n<h2>\u30b5\u30f3\u30d7\u30eb\u5916\u89b3\u306e\u6642\u9593\u5909\u5316<\/h2>\n<p>\u300c\u2460\u5927\u6c17\u300d\u3001\u300c\u2461\u5927\u6c17\uff0b\u6c34\u300d\u306e\u6761\u4ef6\u3067UV\u7167\u5c04\u3057\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u677f\u306b\u3064\u3044\u3066\u306f\u3001UV\u7167\u5c041\u6642\u9593\u3092\u7d4c\u904e\u3059\u308b\u9803\u304b\u3089\u9ec4\u5909\u304c\u307f\u3089\u308c\u307e\u3057\u305f\uff08\u56f32\uff09\u3002<\/p>\n<div id=\"attachment_13805\" style=\"width: 478px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13805\" class=\"size-full wp-image-13805\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-02.png\" alt=\"UV\u7167\u5c04\u306b\u3088\u308b\u30b5\u30f3\u30d7\u30eb\u5916\u89b3\u306e\u6642\u9593\u5909\u5316\" width=\"468\" height=\"430\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-02.png 468w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-02-300x276.png 300w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><p id=\"caption-attachment-13805\" class=\"wp-caption-text\">\u56f32\uff1a UV\u7167\u5c04\u306b\u3088\u308b\u30b5\u30f3\u30d7\u30eb\u5916\u89b3\u306e\u6642\u9593\u5909\u5316<\/p><\/div>\n<h2>\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306e\u6642\u9593\u5909\u5316<\/h2>\n<p>UV\u7167\u5c04\u958b\u59cb\u304b\u30898\u6642\u9593\u5f8c\u307e\u3067\u306e\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u5909\u5316\u306b\u3064\u3044\u3066\u78ba\u8a8d\u3057\u305f\u3068\u3053\u308d\u3001UV\u7167\u5c04\u6761\u4ef6\u300c\u2460\u5927\u6c17\u300d\u304a\u3088\u3073\u300c\u2461\u5927\u6c17\uff0b\u6c34\u300d\u306b\u304a\u3044\u3066\u306f\u30011714 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306eC=O\u7531\u6765\u30d4\u30fc\u30af\u30011066 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306eC-O\u7531\u6765\u30d4\u30fc\u30af\u304c\u51fa\u73fe\u3057\u5897\u52a0\u3059\u308b\u69d8\u5b50\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306f\u3001\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u304c\u9178\u5316\u3055\u308c\u3001\u69cb\u9020\u5909\u5316\u304c\u8d77\u3053\u3063\u305f\u3053\u3068\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001910 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306bC=C-H\u7531\u6765\u30d4\u30fc\u30af\u304c\u51fa\u73fe\u3059\u308b\u69d8\u5b50\u3082\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001\u300c\u2462 \u30ab\u30d0\u30fc\u30ac\u30e9\u30b9\u300d\u306b\u3064\u3044\u3066\u306f\u3001UV\u7167\u5c048\u6642\u9593\u5f8c\u307e\u3067\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306b\u5909\u5316\u306f\u898b\u3089\u308c\u305a\u3001\u9178\u5316\u52a3\u5316\u304c\u8d77\u3053\u3063\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_13802\" style=\"width: 514px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13802\" class=\"size-full wp-image-13802\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-03.png\" alt=\"\u6761\u4ef6\u300c\u2460\u5927\u6c17\u300d\u306e\u5834\u5408\u306eUV\u7167\u5c04\u958b\u59cb\u304b\u30898\u6642\u9593\u5f8c\u307e\u3067\u306e\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u5909\u5316\" width=\"504\" height=\"304\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-03.png 504w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-03-300x181.png 300w\" sizes=\"auto, (max-width: 504px) 100vw, 504px\" \/><p id=\"caption-attachment-13802\" class=\"wp-caption-text\">\u56f33\uff1a\u6761\u4ef6\u300c\u2460\u5927\u6c17\u300d\u306e\u5834\u5408\u306eUV\u7167\u5c04\u958b\u59cb\u304b\u30898\u6642\u9593\u5f8c\u307e\u3067\u306e\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u5909\u5316<\/p><\/div>\n<p>UV\u7167\u5c04\u6761\u4ef6\u300c\u2460\u5927\u6c17\u300d\u304a\u3088\u3073\u300c\u2461\u5927\u6c17\uff0b\u6c34\u300d\u306e\u30011714 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306eC=O\u7531\u6765\u30d4\u30fc\u30af\u9ad8\u3055\u30011066 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306eC-O\u7531\u6765\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u6642\u9593\u5909\u5316\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3092\u898b\u308b\u3068\u6642\u9593\u3068\u3068\u3082\u306b\u5897\u52a0\u3057\u3066\u3044\u308b\u69d8\u5b50\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u300c\u2461\u5927\u6c17\uff0b\u6c34\u300d\u6761\u4ef6\u306e\u65b9\u304c\u5897\u52a0\u306e\u7a0b\u5ea6\u304c\u3088\u308a\u5927\u304d\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u3053\u306e\u3053\u3068\u304b\u3089\u3001\u9178\u5316\u306e\u9032\u884c\u306f\u300c\u2461\u5927\u6c17\uff0b\u6c34\u300d\u6761\u4ef6\u3067\u3088\u308a\u9855\u8457\u3067\u3042\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<br \/>\n\u3055\u3089\u306b\u3001910 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306eC=C-H\u7531\u6765\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u6642\u9593\u5909\u5316\u3092\u78ba\u8a8d\u3057\u305f\u3068\u3053\u308d\u3001\u3053\u3061\u3089\u3082\u300c\u2460\u5927\u6c17\u300d\u304a\u3088\u3073\u300c\u2461\u5927\u6c17\uff0b\u6c34\u300d\u306e2\u6761\u4ef6\u3067\u5897\u52a0\u3059\u308b\u50be\u5411\u304c\u898b\u3089\u308c\u307e\u3059\u304c\u3001UV\u7167\u5c04\u76f4\u5f8c\u304b\u3089200\u5206\u9803\u307e\u3067\u306f\u4e00\u5b9a\u306e\u5272\u5408\u3067\u9806\u8abf\u306b\u5897\u52a0\u3057\u3001250\u5206\u3092\u904e\u304e\u305f\u3042\u305f\u308a\u304b\u3089\u5897\u52a0\u304c\u920d\u5316\u3001\u307b\u307c\u6a2a\u3070\u3044\u72b6\u614b\u3068\u306a\u308b\u69d8\u5b50\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n<p>\u3053\u3053\u3067\u3001\u518d\u5ea6C=O\u3084C-O\u306e\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3092\u78ba\u8a8d\u3059\u308b\u3068\u3001200\u5206\u9803\u307e\u3067\u306f\u3001\u5897\u52a0\u306e\u7a0b\u5ea6\u304c\u3054\u304f\u308f\u305a\u304b\u3067\u3001200\u5206\u3092\u904e\u304e\u305f\u8fba\u308a\u304b\u3089\u3001\u6025\u6fc0\u306a\u5897\u52a0\u306b\u8ee2\u3058\u3066\u3044\u308b\u3053\u3068\u304c\u898b\u3066\u53d6\u308c\u307e\u3059\u3002910 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306eC=C-H\u7531\u6765\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u5897\u3048\u65b9\u3068\u5408\u308f\u305b\u3066\u8003\u3048\u308b\u3068\u3001UV\u7167\u5c04\u306b\u3088\u308a\u307e\u305aC=C-H\u69cb\u9020\u304c\u3067\u304d\u3001\u3053\u308c\u306b\u9178\u7d20\u539f\u5b50\uff08O\uff09\u304c\u7d50\u5408\u3059\u308b\u3053\u3068\u3067\u3001C=O\u3001C-O\u69cb\u9020\u304c\u751f\u6210\u3001\u3053\u308c\u306b\u3088\u308aC=C-H\u69cb\u9020\u304c\u6d88\u8cbb\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u63a8\u5b9a\u3055\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13803\" style=\"width: 842px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13803\" class=\"size-full wp-image-13803\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-04.png\" alt=\"1714\u30011066\u3001910cm-1\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u6642\u9593\u5909\u5316\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\" width=\"832\" height=\"544\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-04.png 832w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-04-300x196.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-04-768x502.png 768w\" sizes=\"auto, (max-width: 832px) 100vw, 832px\" \/><p id=\"caption-attachment-13803\" class=\"wp-caption-text\">\u56f34\uff1a1714\u30011066\u3001910cm<sup>-1<\/sup>\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u6642\u9593\u5909\u5316\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb<\/p><\/div>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306e\u6761\u4ef6\u3092\u5909\u3048\u3001\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u52a3\u5316\u306b\u3064\u3044\u3066\u3001FT-IR\u3092\u7528\u3044\u305f\u8ffd\u8de1\u8a55\u4fa1\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u6761\u4ef6\u306b\u3088\u308a\u3001\u69cb\u9020\u5909\u5316\u306e\u9032\u307f\u65b9\u306b\u9055\u3044\u304c\u898b\u3089\u308c\u3001\u6bb5\u968e\u7684\u306a\u69cb\u9020\u5909\u5316\u304c\u8d77\u304d\u3066\u3044\u308b\u3068\u63a8\u5b9a\u3067\u304d\u308b\u69d8\u5b50\u3082\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n<p>\u95a2\u9023\u60c5\u5831<br \/>\n1 \u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u00a0 \u00a0<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/application-note-ftir056-degradation-assessment-ja.pdf?CID=foreign_material_ft-ir_msd_sales_10_Social_LAB\" target=\"_blank\" rel=\"noopener\">FT-IR\u304a\u3088\u3073\u30e9\u30de\u30f3\u3092\u7528\u3044\u305f\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u8a55\u4fa1<\/a><br \/>\n2 \u95a2\u9023\u88fd\u54c1Web\u30da\u30fc\u30b8\u2192 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/fourier-transform-infrared-ftir-spectroscopy\/ftir-instruments.html?CID=foreign_material_ft-ir_msd_sales_10_Social_LAB\" target=\"_blank\" rel=\"noopener\">Nicolet FT-IR \u88c5\u7f6e<\/a><\/p>\n<p><b>FT-IR\u88fd\u54c1\u306b\u3064\u3044\u3066\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u3092\u304a\u5f85\u3061\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/b><br \/>\n\u30c7\u30e2\u4f7f\u7528\u3084\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3054\u5e0c\u671b\u306e\u65b9\u306f\u4e0b\u8a18\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/ftir-inquiry-form.html?CID=foreign_material_ft-ir_msd_sales_10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6a39\u8102\u306a\u3069\u306e\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u306f\u69d8\u3005\u306a\u8981\u56e0\u3067\u8d77\u3053\u308a\u3001\u7d2b\u5916\u7dda\u306f\u305d\u306e\u8981\u56e0\u306e\u6700\u305f\u308b\u3082\u306e\u306b\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u7d2b\u5916\u7dda\u306b\u3088\u308b\u52a3\u5316\u304c\u9032\u3080\u969b\u3001\u74b0\u5883\u306e\u9055\u3044\u304c\u52a3\u5316\u306e\u9032\u884c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u53ca\u307c\u3059\u306e\u304b\u3092\u8abf\u3079\u308b\u305f\u3081\u3001\u7d2b\u5916\u7dda\u3092\u7167\u5c04\u3057\u5f37\u5236\u7684\u306b\u52a3\u5316\u3092\u9032\u884c\u3055\u305b\u305f<\/p>\n","protected":false},"author":975,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[194],"division":[],"class_list":["post-13798","post","type-post","status-publish","format-standard","category-analysis","tag-ir","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1\" \/>\n<meta property=\"og:description\" content=\"\u6a39\u8102\u306a\u3069\u306e\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u306f\u69d8\u3005\u306a\u8981\u56e0\u3067\u8d77\u3053\u308a\u3001\u7d2b\u5916\u7dda\u306f\u305d\u306e\u8981\u56e0\u306e\u6700\u305f\u308b\u3082\u306e\u306b\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u7d2b\u5916\u7dda\u306b\u3088\u308b\u52a3\u5316\u304c\u9032\u3080\u969b\u3001\u74b0\u5883\u306e\u9055\u3044\u304c\u52a3\u5316\u306e\u9032\u884c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u53ca\u307c\u3059\u306e\u304b\u3092\u8abf\u3079\u308b\u305f\u3081\u3001\u7d2b\u5916\u7dda\u3092\u7167\u5c04\u3057\u5f37\u5236\u7684\u306b\u52a3\u5316\u3092\u9032\u884c\u3055\u305b\u305f\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-04-11T07:24:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-07T07:02:02+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png\" \/>\n\t<meta property=\"og:image:width\" content=\"667\" \/>\n\t<meta property=\"og:image:height\" content=\"246\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1\",\"datePublished\":\"2023-04-11T07:24:17+00:00\",\"dateModified\":\"2025-02-07T07:02:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/\"},\"wordCount\":89,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/foreign_material_ft-ir_msd_sales10-01.png\",\"keywords\":[\"\u8d64\u5916\u5206\u5149\u6cd5\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/\",\"name\":\"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/foreign_material_ft-ir_msd_sales10-01.png\",\"datePublished\":\"2023-04-11T07:24:17+00:00\",\"dateModified\":\"2025-02-07T07:02:02+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#primaryimage\",\"url\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/foreign_material_ft-ir_msd_sales10-01.png\",\"contentUrl\":\"http:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/foreign_material_ft-ir_msd_sales10-01.png\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-ir_msd_sales10\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/","og_locale":"ja_JP","og_type":"article","og_title":"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1","og_description":"\u6a39\u8102\u306a\u3069\u306e\u8eab\u8fd1\u306a\u6750\u6599\u306e\u52a3\u5316\u306f\u69d8\u3005\u306a\u8981\u56e0\u3067\u8d77\u3053\u308a\u3001\u7d2b\u5916\u7dda\u306f\u305d\u306e\u8981\u56e0\u306e\u6700\u305f\u308b\u3082\u306e\u306b\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u7d2b\u5916\u7dda\u306b\u3088\u308b\u52a3\u5316\u304c\u9032\u3080\u969b\u3001\u74b0\u5883\u306e\u9055\u3044\u304c\u52a3\u5316\u306e\u9032\u884c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u53ca\u307c\u3059\u306e\u304b\u3092\u8abf\u3079\u308b\u305f\u3081\u3001\u7d2b\u5916\u7dda\u3092\u7167\u5c04\u3057\u5f37\u5236\u7684\u306b\u52a3\u5316\u3092\u9032\u884c\u3055\u305b\u305f","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-04-11T07:24:17+00:00","article_modified_time":"2025-02-07T07:02:02+00:00","og_image":[{"width":667,"height":246,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1","datePublished":"2023-04-11T07:24:17+00:00","dateModified":"2025-02-07T07:02:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/"},"wordCount":89,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png","keywords":["\u8d64\u5916\u5206\u5149\u6cd5"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/","name":"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#primaryimage"},"thumbnailUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png","datePublished":"2023-04-11T07:24:17+00:00","dateModified":"2025-02-07T07:02:02+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#primaryimage","url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png","contentUrl":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/foreign_material_ft-ir_msd_sales10-01.png"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-ir_msd_sales10\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"FT-IR\u3092\u7528\u3044\u305f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u306e\u7d2b\u5916\u7dda\uff08UV\uff09\u7167\u5c04\u306b\u3088\u308b\u52a3\u5316\u8ffd\u8de1"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":194,"label":"\u8d64\u5916\u5206\u5149\u6cd5"}]},"featured_image_src_large":false,"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":194,"name":"\u8d64\u5916\u5206\u5149\u6cd5","slug":"ir","term_group":0,"term_taxonomy_id":194,"taxonomy":"post_tag","description":"","parent":0,"count":15,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13798","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13798"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13798\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13798"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13798"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13798"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13798"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}