{"id":13898,"date":"2023-04-21T12:41:59","date_gmt":"2023-04-21T03:41:59","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?p=13898"},"modified":"2023-12-27T17:27:45","modified_gmt":"2023-12-27T08:27:45","slug":"basic-workshop-gsd-ts-2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f"},"content":{"rendered":"<p>\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306fDNA\u3092\u30b5\u30a4\u30ba\u3054\u3068\u306b\u5206\u96e2\u3059\u308b\u96fb\u6c17\u6cf3\u52d5\u306e\u969b\u306a\u3069\u306b\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u901a\u5e38\u306f\u3001PCR\u306a\u3069\u3092\u304b\u3051\u3066\u3044\u308b\u5f85\u3061\u6642\u9593\u306e\u9593\u306b\u30a2\u30ac\u30ed\u30fc\u30b9\u7c89\u672b\u3092\u6eb6\u304b\u3057\u3001\u30c8\u30ec\u30fc\u306b\u6d41\u3057\u8fbc\u3093\u3067\u30b2\u30eb\u3092\u4f5c\u6210\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6e96\u5099\u304c\u3067\u304d\u305f\u3089\u3059\u3050\u306b\u96fb\u6c17\u6cf3\u52d5\u306b\u4f7f\u7528\u3057\u307e\u3059\u3002\u3082\u3057\u304f\u306f\u3001\u30b2\u30eb\u304c\u4f59\u3063\u305f\u5834\u5408\u306f\u3001\u30e9\u30c3\u30d7\u306b\u5305\u3093\u3060\u308a\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u306e\u98df\u54c1\u4fdd\u5b58\u5bb9\u5668\u4e2d\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u6d78\u3057\u305f\u308a\u3057\u3066\u51b7\u8535\u4fdd\u5b58\u3059\u308b\u5834\u5408\u3082\u3042\u308b\u304b\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u4eca\u56de\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u4fdd\u5b58\u6e29\u5ea6\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067\u30b2\u30eb\u3092\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u3053\u3068\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u51cd\u3089\u305b\u3066\u3057\u307e\u3048\u3070\u6570\u5e74\u306b\u6e21\u3063\u3066\u5b89\u5b9a\u7684\u306b\u4fdd\u5b58\u3067\u304d\u308b\u304b\u3082\u3057\u308c\u306a\u3044\uff01\u3068\u601d\u3044\u3064\u3044\u305f\u306e\u3067\u3001\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n<h2>\u7d50\u679c<\/h2>\n<p>1%\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u30922\u3064\u7528\u610f\u3057\u3001\u4e7e\u71e5\u9632\u6b62\u306e\u305f\u3081\u306b\u30e9\u30c3\u30d7\u3067\u5305\u307f\u307e\u3057\u305f\u30021\u3064\u306f4 \u2103\u3067\u3001\u3082\u30461\u3064\u306f\u30de\u30a4\u30ca\u30b920 \u2103\u30671\u6669\u4fdd\u5b58\u3057\u3001\u7fcc\u65e5\u306b\u305d\u308c\u305e\u308c\u53d6\u308a\u51fa\u3057\u305f\u969b\u306e\u69d8\u5b50\u304c\u3053\u3061\u3089\u3067\u3059\uff08\u56f31\uff09\u3002\u51b7\u8535\u3057\u305f\u65b9\u306f\u5927\u304d\u306a\u898b\u305f\u76ee\u306e\u5909\u5316\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001\u51b7\u51cd\u3057\u305f\u65b9\u306f\u8868\u9762\u306b\u3057\u308f\u304c\u5bc4\u3063\u3066\u3044\u307e\u3057\u305f\uff08\u56f31\u4e0a\uff09\u3002\u307e\u305f\u3001\u30b2\u30eb\u306e\u539a\u3055\u304c\u3084\u3084\u8584\u304f\u306a\u3063\u3066\u3044\u307e\u3057\u305f\uff08\u56f31\u4e0b\uff09\u3002\u3053\u308c\u306f\u3001\u51cd\u7d50\u3068\u89e3\u51cd\u306e\u904e\u7a0b\u3067\u30b2\u30eb\u4e2d\u306e\u6c34\u5206\u304c\u8131\u6c34\u3055\u308c\u305f\u304b\u3089\u3060\u3068\u601d\u308f\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_13902\" style=\"width: 703px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13902\" class=\"wp-image-13902 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png\" alt=\"\u4fdd\u5b58\u5f8c\u306e\u30b2\u30eb\u306e\u69d8\u5b504\u2103\u51b7\u8535\u4fdd\u5b58\uff08\u5de6\uff09\u3068-20\u2103\u51b7\u51cd\u4fdd\u5b58\uff08\u53f3\uff09\u3057\u305f\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\" width=\"693\" height=\"515\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png 693w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843-300x223.png 300w\" sizes=\"auto, (max-width: 693px) 100vw, 693px\" \/><p id=\"caption-attachment-13902\" class=\"wp-caption-text\">\u56f31 \u4fdd\u5b58\u5f8c\u306e\u30b2\u30eb\u306e\u69d8\u5b50<br \/>4\u2103\u51b7\u8535\u4fdd\u5b58\uff08\u5de6\uff09\u3068-20\u2103\u51b7\u51cd\u4fdd\u5b58\uff08\u53f3\uff09\u3057\u305f\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb<\/p><\/div>\n<p>\u30b2\u30eb\u3092\u5ba4\u6e29\u306b\u623b\u3057\u305f\u5f8c\u3001PCR\u7523\u7269\uff08856 bp\uff09\u3068DNA\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\uff08Invitrogen\u2122 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10787018\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">1 Kb Plus DNA Ladder<\/a>\uff09\u3092\u6cf3\u52d5\u3057\u3066\u307f\u307e\u3057\u305f\u3002<br \/>\n\u51cd\u7d50\u3057\u305f\u65b9\u306e\u30b2\u30eb\u306f\u591a\u6570\u306e\u6c17\u6ce1\u304c\u898b\u3089\u308c\u307e\u3057\u305f\uff08\u56f32\u53f3\uff09\u3002\u51cd\u7d50\u6642\u306b\u30b2\u30eb\u306e\u7db2\u76ee\u69cb\u9020\u306e\u4e2d\u3067\u6c37\u306e\u7d50\u6676\u304c\u3067\u304d\u3066\u3057\u307e\u3063\u305f\u305f\u3081\u3001\u89e3\u51cd\u6642\u306b\u8131\u6c34\u3055\u308c\u3066\u7a7a\u6d1e\u304c\u6b8b\u3063\u305f\u306e\u3060\u3068\u8003\u3048\u3089\u308c\u307e\u3057\u305f\u3002\u51cd\u7d50\u5f8c\u306b\u4e7e\u71e5\u3055\u305b\u3066\u30b2\u30eb\u304b\u3089\u6c34\u5206\u304c\u629c\u3051\u3066\u30b9\u30dd\u30f3\u30b8\u72b6\u306b\u306a\u3063\u305f\u9ad8\u91ce\u8c46\u8150\uff08\u51cd\u307f\u8c46\u8150\uff09\u3092\u30a4\u30e1\u30fc\u30b8\u3059\u308b\u3068\u3001\u4e0a\u8a18\u306e\u73fe\u8c61\u3092\u7406\u89e3\u3057\u3084\u3059\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u9ad8\u91ce\u8c46\u8150\u306f\u51b7\u51cd\u3059\u308b\u3068\u300c\u3059\u300d\u304c\u5165\u3063\u3066\u30b9\u30ab\u30b9\u30ab\u306b\u306a\u308b\u73fe\u8c61\u3092\u5229\u7528\u3057\u305f\u98df\u6750\u306e1\u3064\u3067\u3059\u3002<\/p>\n<div id=\"attachment_13905\" style=\"width: 1371px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13905\" class=\"wp-image-13905 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-02-2-e1681706506423.png\" alt=\"\u96fb\u6c17\u6cf3\u52d5\u5f8c\u306e\u30b2\u30eb\u306e\u69d8\u5b504\u2103\u51b7\u8535\u4fdd\u5b58\uff08\u5de6\uff09\u3001-20\u2103\u51b7\u51cd\u4fdd\u5b58\uff08\u53f3\uff09\" width=\"1361\" height=\"741\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-02-2-e1681706506423.png 1361w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-02-2-e1681706506423-300x163.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-02-2-e1681706506423-1024x558.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-02-2-e1681706506423-768x418.png 768w\" sizes=\"auto, (max-width: 1361px) 100vw, 1361px\" \/><p id=\"caption-attachment-13905\" class=\"wp-caption-text\">\u56f32 \u96fb\u6c17\u6cf3\u52d5\u5f8c\u306e\u30b2\u30eb\u306e\u69d8\u5b50<br \/>4\u2103\u51b7\u8535\u4fdd\u5b58\uff08\u5de6\uff09\u3001-20\u2103\u51b7\u51cd\u4fdd\u5b58\uff08\u53f3\uff09<\/p><\/div>\n<p>\u6cf3\u52d5\u7d50\u679c\u3092\u898b\u3066\u307f\u308b\u3068\u3001\u51b7\u8535\u3057\u305f\u65b9\u306e\u6cf3\u52d5\u50cf\u306f\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\u3082PCR\u7523\u7269\u3082\u306f\u3063\u304d\u308a\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\uff08\u56f33\u5de6\uff09\u3002\u4e00\u65b9\u3067\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u65b9\u306f\u3001\u306a\u3093\u3067\u3057\u3087\u3046\u304b\u3053\u308c\u306f\u30fb\u30fb\u30fb\uff08\u56f33\u53f3\uff09\u3002\u3082\u306f\u3084\u30d0\u30f3\u30c9\u304c\u89b3\u5bdf\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3053\u308c\u306f\u30b2\u30eb\u4e2d\u306b\u591a\u6570\u306e\u6c17\u6ce1\u304c\u767a\u751f\u3057\u3066\u3057\u307e\u3063\u305f\u305f\u3081\u3001\u6c17\u6ce1\u3092\u907f\u3051\u308b\u3088\u3046\u306bDNA\u304c\u6cf3\u52d5\u3055\u308c\u305f\u305f\u3081\u3060\u3068\u601d\u308f\u308c\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u7d50\u679c\u3068\u3057\u3066DNA\u306e\u30b5\u30a4\u30ba\u3054\u3068\u306b\u304d\u3061\u3093\u3068\u5206\u96e2\u3067\u304d\u305a\u3001\u30d0\u30f3\u30c9\u3068\u3057\u3066\u53ef\u8996\u5316\u3067\u304d\u306a\u304b\u3063\u305f\u306e\u3060\u3068\u8003\u3048\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_13906\" style=\"width: 1372px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-13906\" class=\"wp-image-13906 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-03-1-e1681706594809.png\" alt=\"DNA\u306e\u6cf3\u52d5\u50cf4\u2103\u51b7\u8535\u4fdd\u5b58\uff08\u5de6\uff09\u3001-20\u2103\u51b7\u51cd\u4fdd\u5b58\uff08\u53f3\uff09\" width=\"1362\" height=\"813\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-03-1-e1681706594809.png 1362w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-03-1-e1681706594809-300x179.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-03-1-e1681706594809-1024x611.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-03-1-e1681706594809-768x458.png 768w\" sizes=\"auto, (max-width: 1362px) 100vw, 1362px\" \/><p id=\"caption-attachment-13906\" class=\"wp-caption-text\">\u56f33 DNA\u306e\u6cf3\u52d5\u50cf<br \/>4\u2103\u51b7\u8535\u4fdd\u5b58\uff08\u5de6\uff09\u3001-20\u2103\u51b7\u51cd\u4fdd\u5b58\uff08\u53f3\uff09<\/p><\/div>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3059\u308b\u3068\u6c17\u6ce1\u304c\u305f\u304f\u3055\u3093\u5165\u3063\u3066\u3057\u307e\u3044\u3001\u3046\u307e\u304f\u96fb\u6c17\u6cf3\u52d5\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002\u5927\u91cf\u306b\u30b2\u30eb\u3092\u4f5c\u6210\u3057\u3066\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304a\u304f\u3068\u3044\u3046\u52b9\u7387\u5316\u304c\u3067\u304d\u308c\u3070\u3068\u601d\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u79c1\u306e\u91ce\u671b\u306f\u3082\u308d\u304f\u3082\u5d29\u308c\u53bb\u3063\u3066\u3057\u307e\u3044\u307e\u3057\u305f\u3002<\/p>\n<p>\u5f53\u793e\u3067\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u3084PCR\u306a\u3069\u5b9f\u969b\u306b\u5b9f\u9a13\uff08\u5b9f\u7fd2\uff09\u3092\u884c\u3044\u3064\u3064\u5b66\u3079\u308b\u5404\u7a2e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3092\u958b\u50ac\u3057\u3066\u3044\u307e\u3059\u3002\u4ed6\u306b\u3082RNA\u62bd\u51fa\u3084\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3068\u3044\u3063\u305f\u6838\u9178\u95a2\u9023\u3060\u3051\u3067\u306a\u304f\u3001\u7d30\u80de\u57f9\u990a\u3084\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3068\u3044\u3063\u305f\u30b3\u30fc\u30b9\u306e\u3054\u7528\u610f\u3082\u3054\u3056\u3044\u307e\u3059\u3002\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3067\u306f\u3001\u4eca\u56de\u306e\u3088\u3046\u306a\u5b9f\u9a13\u7d50\u679c\u3082\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u3053\u308c\u304b\u3089\u65b0\u3057\u3044\u5b9f\u9a13\u3092\u59cb\u3081\u3089\u308c\u308b\u65b9\u3001\u3088\u308a\u7406\u89e3\u3092\u6df1\u3081\u305f\u3044\u65b9\u306f\u305c\u3072\u3054\u53c2\u52a0\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u4eca\u56de\u306e\u8a18\u4e8b\u306b\u95a2\u9023\u3059\u308b\u3001\u904e\u53bb\u306eBlog\uff1a<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/workshop-agarose-gel-ts1\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u96fb\u6c17\u6cf3\u52d5\u306e\u30d0\u30f3\u30c9\u304c\u592a\u304f\u306a\u308b\u539f\u56e0\u306f\u300c\u30d0\u30f3\u30c9\u304c\u659c\u3081\u300d<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agarose_gel_electrophoresis_workshop_bid_ts_1\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u3067DNA\u304c\u5206\u96e2\u3057\u3066\u3044\u304f\u52d5\u753b\u3092\u64ae\u5f71\u3057\u3066\u307f\u305f<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/cloning-learning-center\/invitrogen-school-of-molecular-biology\/na-electrophoresis-education\/na-separation-overview.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u6838\u9178\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u2015\u6982\u8981\u3068\u6b74\u53f2<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/cloning-learning-center\/invitrogen-school-of-molecular-biology\/na-electrophoresis-education\/na-electrophoresis-workflow.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u6838\u9178\u96fb\u6c17\u6cf3\u52d5\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u2015\u4e3b\u306a 5 \u3064\u306e\u30b9\u30c6\u30c3\u30d7<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/cloning-learning-center\/invitrogen-school-of-molecular-biology\/na-electrophoresis-education\/na-electrophoresis-considerations.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u6838\u9178\u96fb\u6c17\u6cf3\u52d5\u306e7\u3064\u306e\u6ce8\u610f\u70b9<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cloning\/cloning-learning-center\/invitrogen-school-of-molecular-biology\/na-electrophoresis-education\/na-electrophoresis-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u6838\u9178\u96fb\u6c17\u6cf3\u52d5\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306fDNA\u3092\u30b5\u30a4\u30ba\u3054\u3068\u306b\u5206\u96e2\u3059\u308b\u96fb\u6c17\u6cf3\u52d5\u306e\u969b\u306a\u3069\u306b\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u901a\u5e38\u306f\u3001PCR\u306a\u3069\u3092\u304b\u3051\u3066\u3044\u308b\u5f85\u3061\u6642\u9593\u306e\u9593\u306b\u30a2\u30ac\u30ed\u30fc\u30b9\u7c89\u672b\u3092\u6eb6\u304b\u3057\u3001\u30c8\u30ec\u30fc\u306b\u6d41\u3057\u8fbc\u3093\u3067\u30b2\u30eb\u3092\u4f5c\u6210\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6e96\u5099\u304c\u3067\u304d\u305f\u3089\u3059\u3050\u306b\u96fb<\/p>\n","protected":false},"author":975,"featured_media":13902,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[9,28],"division":[],"class_list":["post-13898","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-pcr","tag-experiment","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u4eca\u56de\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u4fdd\u5b58\u6e29\u5ea6\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067\u30b2\u30eb\u3092\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u3053\u3068\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u51cd\u3089\u305b\u3066\u3057\u307e\u3048\u3070\u6570\u5e74\u306b\u6e21\u3063\u3066\u5b89\u5b9a\u7684\u306b\u4fdd\u5b58\u3067\u304d\u308b\u304b\u3082\u3057\u308c\u306a\u3044\uff01\u3068\u601d\u3044\u3064\u3044\u305f\u306e\u3067\u3001\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f\" \/>\n<meta property=\"og:description\" content=\"\u4eca\u56de\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u4fdd\u5b58\u6e29\u5ea6\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067\u30b2\u30eb\u3092\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u3053\u3068\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u51cd\u3089\u305b\u3066\u3057\u307e\u3048\u3070\u6570\u5e74\u306b\u6e21\u3063\u3066\u5b89\u5b9a\u7684\u306b\u4fdd\u5b58\u3067\u304d\u308b\u304b\u3082\u3057\u308c\u306a\u3044\uff01\u3068\u601d\u3044\u3064\u3044\u305f\u306e\u3067\u3001\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-04-21T03:41:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-27T08:27:45+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png\" \/>\n\t<meta property=\"og:image:width\" content=\"693\" \/>\n\t<meta property=\"og:image:height\" content=\"515\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f\",\"datePublished\":\"2023-04-21T03:41:59+00:00\",\"dateModified\":\"2023-12-27T08:27:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/\"},\"wordCount\":44,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/basic-workshop-gsd-ts-2-01-e1681706465843.png\",\"keywords\":[\"PCR\",\"\u3084\u3063\u3066\u307f\u305f\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/basic-workshop-gsd-ts-2-01-e1681706465843.png\",\"datePublished\":\"2023-04-21T03:41:59+00:00\",\"dateModified\":\"2023-12-27T08:27:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"description\":\"\u4eca\u56de\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u4fdd\u5b58\u6e29\u5ea6\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067\u30b2\u30eb\u3092\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u3053\u3068\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u51cd\u3089\u305b\u3066\u3057\u307e\u3048\u3070\u6570\u5e74\u306b\u6e21\u3063\u3066\u5b89\u5b9a\u7684\u306b\u4fdd\u5b58\u3067\u304d\u308b\u304b\u3082\u3057\u308c\u306a\u3044\uff01\u3068\u601d\u3044\u3064\u3044\u305f\u306e\u3067\u3001\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/basic-workshop-gsd-ts-2-01-e1681706465843.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/04\\\/basic-workshop-gsd-ts-2-01-e1681706465843.png\",\"width\":693,\"height\":515},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f - Learning at the Bench","description":"\u4eca\u56de\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u4fdd\u5b58\u6e29\u5ea6\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067\u30b2\u30eb\u3092\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u3053\u3068\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u51cd\u3089\u305b\u3066\u3057\u307e\u3048\u3070\u6570\u5e74\u306b\u6e21\u3063\u3066\u5b89\u5b9a\u7684\u306b\u4fdd\u5b58\u3067\u304d\u308b\u304b\u3082\u3057\u308c\u306a\u3044\uff01\u3068\u601d\u3044\u3064\u3044\u305f\u306e\u3067\u3001\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f","og_description":"\u4eca\u56de\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u4fdd\u5b58\u6e29\u5ea6\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067\u30b2\u30eb\u3092\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u3053\u3068\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u51cd\u3089\u305b\u3066\u3057\u307e\u3048\u3070\u6570\u5e74\u306b\u6e21\u3063\u3066\u5b89\u5b9a\u7684\u306b\u4fdd\u5b58\u3067\u304d\u308b\u304b\u3082\u3057\u308c\u306a\u3044\uff01\u3068\u601d\u3044\u3064\u3044\u305f\u306e\u3067\u3001\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-04-21T03:41:59+00:00","article_modified_time":"2023-12-27T08:27:45+00:00","og_image":[{"width":693,"height":515,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f","datePublished":"2023-04-21T03:41:59+00:00","dateModified":"2023-12-27T08:27:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/"},"wordCount":44,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png","keywords":["PCR","\u3084\u3063\u3066\u307f\u305f"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png","datePublished":"2023-04-21T03:41:59+00:00","dateModified":"2023-12-27T08:27:45+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"description":"\u4eca\u56de\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u306e\u4fdd\u5b58\u6e29\u5ea6\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u3053\u308c\u307e\u3067\u30b2\u30eb\u3092\u51b7\u51cd\u4fdd\u5b58\u3057\u305f\u3053\u3068\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u3001\u51cd\u3089\u305b\u3066\u3057\u307e\u3048\u3070\u6570\u5e74\u306b\u6e21\u3063\u3066\u5b89\u5b9a\u7684\u306b\u4fdd\u5b58\u3067\u304d\u308b\u304b\u3082\u3057\u308c\u306a\u3044\uff01\u3068\u601d\u3044\u3064\u3044\u305f\u306e\u3067\u3001\u5b9f\u969b\u306b\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png","width":693,"height":515},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u3092\u51cd\u7d50\u4fdd\u5b58\u3057\u3066\u304b\u3089DNA\u3092\u96fb\u6c17\u6cf3\u52d5\u3057\u3066\u307f\u305f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":9,"label":"PCR"},{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png",693,515,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":9,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":9,"taxonomy":"post_tag","description":"","parent":0,"count":29,"filter":"raw","meta":[]},{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/04\/basic-workshop-gsd-ts-2-01-e1681706465843.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=13898"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/13898\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/13902"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=13898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=13898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=13898"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=13898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}