{"id":1390,"date":"2018-09-21T00:00:00","date_gmt":"2018-09-20T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/"},"modified":"2023-08-17T15:36:13","modified_gmt":"2023-08-17T06:36:13","slug":"phthalatequantitationgcms","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/","title":{"rendered":"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f"},"content":{"rendered":"<p>\u98df\u7528\u6cb9\uff08\u307e\u305f\u306f\u5b89\u4fa1\u306a\u30aa\u30a4\u30eb\uff09\u306b\u8fb2\u85ac\u3001\u6c5a\u67d3\u7269\u8cea\u306a\u3069\u306e\u6709\u5bb3\u7269\u8cea\u304c\u306a\u3044\u3053\u3068\u3092\u8a3c\u660e\u3059\u308b\u305f\u3081\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3068\u3057\u3066\u5805\u7262\u306a\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\uff08GC\uff09\u306f\u91cd\u8981\u3067\u3059\u3002<\/p>\n<p>\u5b89\u5fc3\u5b89\u5168\u306a\u9ad8\u7d14\u5ea6\u306e\u98df\u7528\u6cb9\u304c\u5bb9\u5668\u306b\u5165\u3063\u3066\u3044\u305f\u3068\u3057\u3066\u3082\u3001\u30e9\u30dc\u3067\u3082\u3046\u4e00\u5ea6\u54c1\u8cea\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3046\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u3068\u3044\u3046\u306e\u306f\u3001\u5b9f\u306f\u5bb9\u5668\u304c\u554f\u984c\u3060\u304b\u3089\u3067\u3059\u3002\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u306f\u3001\u98df\u54c1\u5305\u88c5\u3084\u4ed6\u306e\u98df\u54c1\u63a5\u89e6\u6750\u6599\uff08FCM\uff09\u306b\u4f7f\u7528\u3055\u308c\u308b\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u306e\u67d4\u8edf\u6027\u3092\u9ad8\u3081\u308b\u53ef\u5851\u5264\u3068\u3057\u3066\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002 \u3057\u304b\u3057\u3001\u3053\u306e\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u306e\u5316\u5408\u7269\u306f\u89aa\u30dd\u30ea\u30de\u30fc\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u5316\u5b66\u7684\u306b\u7d50\u5408\u3057\u3066\u3044\u306a\u3044\u305f\u3081\u3001\u8868\u9762\u7684\u306b\u306f\u5b89\u5168\u306b\u898b\u3048\u3066\u3082\u3001\u591a\u91cf\u306e\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u304c\u98df\u54c1\u306b\u79fb\u3063\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u306e\u306f\u78ba\u304b\u3067\u3059\u3002<\/p>\n<h2>\u98df\u54c1\u691c\u67fb\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u304a\u3051\u308b\u3001\u5805\u7262\u306aGC-MS\u3092\u7528\u3044\u305f\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0<\/h2>\n<p>\u8fd1\u5e74\u3001\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u304c\u308f\u305f\u3057\u305f\u3061\u4eba\u9593\u306e\u3055\u307e\u3056\u307e\u306a\u5065\u5eb7\u554f\u984c\u306b\u5f71\u97ff\u3059\u308b\u3053\u3068\u304c\u6b21\u3005\u3068\u660e\u3089\u304b\u306b\u306a\u3063\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u5185\u5206\u6ccc\u304b\u304f\u4e71\u7269\u8cea\u3068\u3057\u3066\u5206\u985e\u3055\u308c\u308b\u30d5\u30bf\u30eb\u9178\u306f\u3001\u30db\u30eb\u30e2\u30f3\u3092\u9a5a\u304f\u307b\u3069\u5de7\u307f\u306b\u6a21\u5023\u3057\u3001\u5185\u5206\u6ccc\u7cfb\u306e\u6b63\u5e38\u6a5f\u80fd\u3092\u5909\u3048\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u5b50\u4f9b\u306e\u81ea\u9589\u75c7\u306e\u767a\u9054\u3084\u3001\u69d8\u3005\u306a\u751f\u6b96\u6a5f\u80fd\u306e\u554f\u984c\u306b\u6df1\u304f\u95a2\u308f\u3063\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u554f\u984c\u304b\u3089\u6d88\u8cbb\u8005\u306e\u5065\u5eb7\u3092\u5b88\u308b\u305f\u3081\u306b\u3001\u4e16\u754c\u306e\u98df\u54c1\u5b89\u5168\u6a5f\u95a2\u306f\u98df\u54c1\u63a5\u89e6\u6750\u6599\uff08FCM\uff09\u304b\u3089\u98df\u54c1\u3078\u30d5\u30bf\u30eb\u9178\u304c\u79fb\u884c\u3057\u306a\u3044\u3088\u3046\u3001\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3092\u5236\u5b9a\u3057\u307e\u3057\u305f\u3002\u4f8b\u3048\u3070\u3001\u6b27\u5dde\u98df\u54c1\u5b89\u5168\u6a5f\u95a2\uff08European Food Safety Authority\uff09\u306f\u3001\u6700\u7d42\u7684\u306aFCM\u88fd\u54c1\u306e0.1\uff05\u3067\u98df\u54c1\u3068\u63a5\u89e6\u3059\u308b\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u6750\u6599\u306b\u304a\u3044\u3066\u3001\u7279\u5b9a\u5316\u5b66\u7269\u8cea\u306e\u6df7\u5165\u5236\u9650\u3092\u8a2d\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002 \u540c\u69d8\u306b\u3001\u4e2d\u56fd\u304a\u3088\u3073\u53f0\u6e7e\u306e\u898f\u5236\u6a5f\u95a2\u306f\u30011000\u03bcg\/ kg\u306b\u5bfe\u3057\u3066\u98df\u54c1\u4e2d\u306e1 ppm\uff081 ppm\uff09\u307e\u3067\u306e\u6df7\u5165\u5236\u9650\u3092\u8a2d\u3051\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u80cc\u666f\u304b\u3089\u3001\u98df\u54c1\u691c\u67fb\u6a5f\u95a2\u306f\u3001\u5fae\u91cf\u306a\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u3092\u6b63\u78ba\u306b\u5b9a\u91cf\u3059\u308b\u305f\u3081\u306b\u3001 \u975e\u5e38\u306b\u9ad8\u611f\u5ea6\u3067\u5805\u7262\u306a\u5206\u6790\u6280\u8853\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u65e5\u3005\u9032\u5316\u3059\u308bGC-MS\u6280\u8853\u306f\u3001\u3088\u308a\u9ad8\u611f\u5ea6\u3067\u9078\u629e\u6027\u306e\u3042\u308b\u3001\u5805\u7262\u306a\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u306e\u98df\u54c1\u691c\u67fb\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u78ba\u7acb\u3092\u53ef\u80fd\u306b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u98df\u7528\u6cb9\u306b\u304a\u3051\u308b\u9ad8\u611f\u5ea6GC-MS\u306e\u5206\u6790\u6280\u8853<\/h2>\n<p>\u30d5\u30bf\u30eb\u9178\u306f\u89aa\u6cb9\u6027\u306e\u6027\u8cea\u304c\u3042\u308b\u306e\u3067\u3001\u98df\u7528\u6cb9\u306e\u3088\u3046\u306a\u8102\u80aa\u6027\u98df\u54c1\u306b\u3068\u3063\u3066\u3001\u30d5\u30bf\u30eb\u9178\u304c\u6df7\u5165\u3059\u308b\u3053\u3068\u306f\u7279\u306b\u554f\u984c\u3067\u3059\u3002\u5317\u7c73\u3001\u6b27\u5dde\u3001\u30a2\u30b8\u30a2\u306e\u6d88\u8cbb\u8005\u5e02\u5834\u3067\u8ca9\u58f2\u3055\u308c\u3066\u3044\u308b\u690d\u7269\u6cb9\u4e2d\u306e\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u306e\u30ec\u30d9\u30eb\u304c\u4e00\u8cab\u3057\u3066\u9ad8\u3044\u3053\u3068\u304c\u7814\u7a76\u3067\u3082\u660e\u3089\u304b\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u305d\u3046\u3057\u305f\u3053\u3068\u304b\u3089\u3001\u98df\u7528\u6cb9\u4e2d\u306e\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u306eGC-MS\u5206\u6790\u306f\u3001\u98df\u54c1\u691c\u67fb\u3092\u884c\u3046\u30e9\u30dc\u306b\u3068\u3063\u3066\u91cd\u8981\u306a\u8ab2\u984c\u3067\u3059\u3002 \u3057\u304b\u3057\u3001\u690d\u7269\u6cb9\u306b\u306f\u30c8\u30ea\u30a2\u30b7\u30eb\u30b0\u30ea\u30bb\u30ea\u30c9\u306e\u3088\u3046\u306a\u8907\u96d1\u306a\u6df7\u5408\u7269\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3084\u5206\u6790\u3092\u884c\u3046\u4e0a\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u4f5c\u6210\u304c\u56f0\u96e3\u3067\u3059\u3002\u3055\u3089\u306b\u3001\u5bb9\u6613\u306b\u30a4\u30aa\u30f3\u5316\u3067\u304d\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5316\u5408\u7269\u306e\u5b58\u5728\u4e0b\u3067\u306f\u3001\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304b\u3089\u30d5\u30bf\u30eb\u9178\u5869\u3092\u8b58\u5225\u3059\u308b\u3053\u3068\u304c\u6975\u3081\u3066\u56f0\u96e3\u3067\u3059\u3002\u7279\u306b\u30d5\u30eb\u30b9\u30ad\u30e3\u30f3\u3092\u99c6\u4f7f\u3057\u305f\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3067\u3042\u308c\u3070\u3001\u306a\u304a\u3055\u3089\u3067\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5316\u5408\u7269\u306e\u8907\u96d1\u3055\u3092\u4f4e\u6e1b\u3059\u308b1\u3064\u306e\u65b9\u6cd5\u306f\u3001\u9078\u629e\u30a4\u30aa\u30f3\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\uff08SIM\uff09\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3059\u3002 Timed-SIM\u306f\u3001\u3088\u308a\u9ad8\u611f\u5ea6\u306a\u5206\u6790\u7269\u691c\u51fa\u3092\u53ef\u80fd\u306b\u3059\u308b\u5b9a\u91cf\u30d5\u30bf\u30eb\u9178\u5206\u6790\u306b\u6700\u9069\u306a\u9078\u629e\u80a2\u3067\u3059\u3002\u30c7\u30fc\u30bf\u304c\u5168\u8cea\u91cf\u7bc4\u56f2\u3067\u306f\u306a\u304f\u7279\u5b9a\u306e\u8cea\u91cf\u306b\u3064\u3044\u3066\u306e\u307f\u5f97\u3089\u308c\u308b\u3053\u3068\u3067\u3001\u30b9\u30da\u30af\u30c8\u30eb\u306e\u8907\u96d1\u3055\u304c\u5927\u5e45\u306b\u4f4e\u6e1b\u3055\u308c\u308b\u304b\u3089\u3067\u3059\u3002\u305d\u3053\u3067\u3001SIM\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u5b9f\u8a3c\u3059\u308b\u305f\u3081\u3001\u9ad8\u6027\u80fd\u3068\u3057\u3066\u5b9a\u8a55\u306e\u3042\u308bThermo Scientific ISQ 7000\u30b7\u30f3\u30b0\u30eb\u56db\u91cd\u6975AEI GC-MS\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u3001\u690d\u7269\u6cb9\u4e2d\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u691c\u51fa\u3092\u884c\u3044\u307e\u3057\u305f\u3002Thermo Scientific\u306eChromeleon Chromatography Data System\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u4f7f\u7528\u3057\u3001\u30b9\u30ad\u30e3\u30f3\u901f\u5ea6\u304a\u3088\u3073\u6ede\u7559\u6642\u9593\u3092\u6700\u9069\u5316\u3059\u308b\u3068\u30010.01ng \/ mL\uff080.1\u03bcg\uff09\u306e\u4f4e\u30ec\u30d9\u30eb\u3067\u30d5\u30bf\u30eb\u9178\u30d3\u30b9(2-\u30a8\u30c1\u30eb\u30d8\u30ad\u30b7\u30eb)(DEHP)\u304a\u3088\u3073\u30b8\u30d6\u30c1\u30eb\u30d5\u30bf\u30ec\u30fc\u30c8\uff08DBP\uff09\u304c\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002 \u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u306e\u4e3b\u8981\u306a\u5206\u6790\u5bfe\u8c61\u7269\u306b\u304a\u3051\u308b\u5b9a\u91cf\u9650\u754c\u306f\u30015\u301c25\u03bcg\/ kg\u306e\u7bc4\u56f2\u3067\u3057\u305f\u3002\u3053\u306e\u985e\u307e\u308c\u306a\u308b\u611f\u5ea6\u3068\u9078\u629e\u6027\u3092\u652f\u3048\u308b\u306e\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u306e\u9ad8\u5ea6\u306aAEI\u30a4\u30aa\u30f3\u6e90\u3067\u3059\u3002 \u305d\u306e\u9769\u65b0\u7684\u306a\u30bd\u30fc\u30b9\u5f62\u72b6\u306f\u3001\u30a4\u30aa\u30f3\u5316\u52b9\u7387\u3092\u9ad8\u3081\u3001\u30a4\u30aa\u30f3\u30d3\u30fc\u30e0\u3092\u72ed\u304f\u3057\u307e\u3059\u3002 AEI\u30a4\u30aa\u30f3\u6e90\u3092\u4f7f\u7528\u3057\u3066\u5411\u4e0a\u3057\u305f\u611f\u5ea6\u306f\u3001\u3088\u308a\u5e0c\u91c8\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u4f7f\u7528\u304a\u3088\u3073\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u306e\u5897\u52a0\u3092\u53ef\u80fd\u306b\u3057\u3001GC\u6d41\u8def\u306e\u6c5a\u67d3\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u307e\u3059\u3002 \u3053\u308c\u306b\u3088\u308a\u3001\u5e83\u7bc4\u56f2\u3067\u3001\u305d\u3057\u3066\u9ad8\u4fa1\u306a\u30b5\u30f3\u30d7\u30eb\u306e\u6e96\u5099\u3001\u8a08\u5668\u306e\u4fdd\u5b88\u3068\u6d88\u8017\u54c1\u306e\u4ea4\u63db\u304c\u4e0d\u8981\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u6700\u65b0\u306eGC-MS\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306f\u3001\u98df\u54c1\u5305\u88c5\u6750\u6599\u5206\u6790\u3067\u3001\u6d88\u8cbb\u8005\u306e\u5065\u5eb7\u30ea\u30b9\u30af\u3092\u5b88\u308b\u5f37\u529b\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u3066\u3044\u307e\u3059\u3002 \u3053\u3046\u3057\u305f\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306f\u3001AEI\u30a4\u30aa\u30f3\u6e90\u3068Timed-SIM\u306e\u7372\u5f97\u6280\u8853\u306b\u3088\u308a\u3001\u73fe\u4ee3\u306e\u98df\u54c1\u691c\u67fb\u898f\u683c\u306b\u8981\u6c42\u3055\u308c\u308b\u9ad8\u54c1\u8cea\u30ec\u30d9\u30eb\u306e\u611f\u5ea6\u3001\u9078\u629e\u6027\u3001\u5805\u7262\u6027\u3092\u6e80\u305f\u3057\u3066\u3044\u307e\u3059\u3002\u98df\u7528\u6cb9\u4e2d\u306e\u9ad8\u611f\u5ea6\u3067\u9078\u629e\u7684\u3067\u5805\u7262\u306a\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u5316\u306b\u3064\u3044\u3066\u3001\u3055\u3089\u306b\u304a\u77e5\u308a\u306b\u306a\u308a\u305f\u3044\u65b9\u306f\u3001\u5f0a\u793e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u300c<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CMD\/Application-Notes\/an-10589-gc-ms-phthalates-vegetable-oil-an10589-en.pdf?ICID=cmd_gc_r04_jp_phthalatequantitationgcms_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30b7\u30f3\u30b0\u30eb\u56db\u91cd\u6975GC-MS\u306b\u3088\u308b\u690d\u7269\u6cb9\u4e2d\u306e\u30d5\u30bf\u30ec\u30fc\u30c8\u306e\u30eb\u30fc\u30c1\u30f3\u6e2c\u5b9a\uff08\u82f1\u8a9e\uff09<\/a>\u300d\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<br \/>\n&nbsp;<br \/>\n<span style=\"font-size: 8pt\">\u203b\u672c\u8a18\u4e8b\u306f\u4e0b\u8a18\u30da\u30fc\u30b8\u3092\u7ffb\u8a33\u3057\u305f\u3082\u306e\u3092\u63b2\u8f09\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/span><br \/>\n<a href=\"http:\/\/analyteguru.com\/sensitive-phthalate-quantitation-in-cooking-oil-by-gc-ms\/?ICID=cmd_gc_r04_jp_phthalatequantitationgcms_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\"><span style=\"font-size: 8pt\">http:\/\/analyteguru.com\/sensitive-phthalate-quantitation-in-cooking-oil-by-gc-ms\/<\/span><\/a><br \/>\n&nbsp;<\/p>\n<ul>\n<li>\u00a0GC-MS\u306b\u95a2\u3059\u308b\u30ea\u30bd\u30fc\u30b9<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/mass-spectrometry\/mass-spectrometry-learning-center\/gas-chromatography-mass-spectrometry-gc-ms-information.html?ICID=cmd_gc_r04_jp_phthalatequantitationgcms_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u8cea\u91cf\u5206\u6790\uff08GC-MS\uff09\u3068\u306f<\/a><\/li>\n<\/ul>\n<p>&nbsp;&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u98df\u7528\u6cb9\uff08\u307e\u305f\u306f\u5b89\u4fa1\u306a\u30aa\u30a4\u30eb\uff09\u306b\u8fb2\u85ac\u3001\u6c5a\u67d3\u7269\u8cea\u306a\u3069\u306e\u6709\u5bb3\u7269\u8cea\u304c\u306a\u3044\u3053\u3068\u3092\u8a3c\u660e\u3059\u308b\u305f\u3081\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3068\u3057\u3066\u5805\u7262\u306a\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\uff08GC\uff09\u306f\u91cd\u8981\u3067\u3059\u3002 \u5b89\u5fc3\u5b89\u5168\u306a\u9ad8\u7d14\u5ea6\u306e\u98df\u7528\u6cb9\u304c\u5bb9\u5668\u306b\u5165\u3063\u3066\u3044\u305f\u3068\u3057\u3066\u3082\u3001\u30e9\u30dc\u3067\u3082\u3046\u4e00\u5ea6\u54c1\u8cea\u30c1<\/p>\n","protected":false},"author":988,"featured_media":4814,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[],"division":[],"class_list":{"0":"post-1390","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-analysis","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f\" \/>\n<meta property=\"og:description\" content=\"\u98df\u7528\u6cb9\uff08\u307e\u305f\u306f\u5b89\u4fa1\u306a\u30aa\u30a4\u30eb\uff09\u306b\u8fb2\u85ac\u3001\u6c5a\u67d3\u7269\u8cea\u306a\u3069\u306e\u6709\u5bb3\u7269\u8cea\u304c\u306a\u3044\u3053\u3068\u3092\u8a3c\u660e\u3059\u308b\u305f\u3081\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3068\u3057\u3066\u5805\u7262\u306a\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\uff08GC\uff09\u306f\u91cd\u8981\u3067\u3059\u3002 \u5b89\u5fc3\u5b89\u5168\u306a\u9ad8\u7d14\u5ea6\u306e\u98df\u7528\u6cb9\u304c\u5bb9\u5668\u306b\u5165\u3063\u3066\u3044\u305f\u3068\u3057\u3066\u3082\u3001\u30e9\u30dc\u3067\u3082\u3046\u4e00\u5ea6\u54c1\u8cea\u30c1\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-09-20T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-17T06:36:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"650\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f\",\"datePublished\":\"2018-09-20T15:00:00+00:00\",\"dateModified\":\"2023-08-17T06:36:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/\"},\"wordCount\":56,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg\",\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/\",\"name\":\"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg\",\"datePublished\":\"2018-09-20T15:00:00+00:00\",\"dateModified\":\"2023-08-17T06:36:13+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg\",\"width\":650,\"height\":650,\"caption\":\"isq-7000-trace-1310-triplus-rsh-left-1200x1200.jpg-650\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/phthalatequantitationgcms\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/","og_locale":"ja_JP","og_type":"article","og_title":"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f","og_description":"\u98df\u7528\u6cb9\uff08\u307e\u305f\u306f\u5b89\u4fa1\u306a\u30aa\u30a4\u30eb\uff09\u306b\u8fb2\u85ac\u3001\u6c5a\u67d3\u7269\u8cea\u306a\u3069\u306e\u6709\u5bb3\u7269\u8cea\u304c\u306a\u3044\u3053\u3068\u3092\u8a3c\u660e\u3059\u308b\u305f\u3081\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3068\u3057\u3066\u5805\u7262\u306a\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\uff08GC\uff09\u306f\u91cd\u8981\u3067\u3059\u3002 \u5b89\u5fc3\u5b89\u5168\u306a\u9ad8\u7d14\u5ea6\u306e\u98df\u7528\u6cb9\u304c\u5bb9\u5668\u306b\u5165\u3063\u3066\u3044\u305f\u3068\u3057\u3066\u3082\u3001\u30e9\u30dc\u3067\u3082\u3046\u4e00\u5ea6\u54c1\u8cea\u30c1","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-09-20T15:00:00+00:00","article_modified_time":"2023-08-17T06:36:13+00:00","og_image":[{"width":650,"height":650,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f","datePublished":"2018-09-20T15:00:00+00:00","dateModified":"2023-08-17T06:36:13+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/"},"wordCount":56,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg","articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/","name":"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg","datePublished":"2018-09-20T15:00:00+00:00","dateModified":"2023-08-17T06:36:13+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg","width":650,"height":650,"caption":"isq-7000-trace-1310-triplus-rsh-left-1200x1200.jpg-650"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/phthalatequantitationgcms\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"GC-MS\u3067\u884c\u3046\u98df\u7528\u6cb9\u306e\u9ad8\u611f\u5ea6\u30d5\u30bf\u30eb\u9178\u306e\u5b9a\u91cf\u3068\u306f\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg",650,650,false],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":106,"filter":"raw","meta":[],"cat_ID":157,"category_count":106,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":1390,"position":0},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":1390,"position":1},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24495,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/laboratory-nalgene-lpd-25076\/","url_meta":{"origin":1390,"position":2},"title":"\u30e9\u30dc\u30dc\u30c8\u30eb\u306f\u3059\u3054\u3044\uff01\uff5e\u30e9\u30dc\u3067\u4f7f\u3046\u30dc\u30c8\u30eb\u306e\u79d8\u5bc6\u3092\u63a2\u308b\uff5e","author":"LatB Staff","date":"2025\u5e7412\u670824\u65e5","format":false,"excerpt":"\u65e5\u5e38\u751f\u6d3b\u3067\u4f7f\u3046\u30dc\u30c8\u30eb\u3068\u3001\u30e9\u30dc\u3067\u4f7f\u3046\u30dc\u30c8\u30eb\u3068\u3067\u306f\u4f55\u304c\u9055\u3046\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u4e00\u822c\u7684\u306a\u30dc\u30c8\u30eb\u3068\u30e9\u30dc\u30dc\u30c8\u30eb\u3068\u306e\u9055\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/laboratory-nalgene-lpd-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":1390,"position":3},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24627,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-semiconductors-lpd-26006\/","url_meta":{"origin":1390,"position":4},"title":"\u9078\u3070\u308c\u308b\u7406\u7531\u304c\u3042\u308b\uff1aThermo Scientific\u771f\u7a7a\u30aa\u30fc\u30d6\u30f3\uff5e\u9ad8\u6e29\u30fb\u9ad8\u771f\u7a7a\u304c\u751f\u307f\u51fa\u3059\u3001\u7cbe\u5bc6\u30d7\u30ed\u30bb\u30b9\u3068\u4fe1\u983c\u6027\uff5e","author":"LatB Staff","date":"2026\u5e741\u670830\u65e5","format":false,"excerpt":"\u88fd\u54c1\u3084\u6750\u6599\u306e\u54c1\u8cea\u3092\u9ad8\u3081\u308b\u3046\u3048\u3067\u3001\u4e7e\u71e5\u30fb\u52a0\u71b1\u30fb\u8131\u6ce1\u3068\u3044\u3063\u305f\u30d7\u30ed\u30bb\u30b9\u306f\u6b20\u304b\u305b\u306a\u3044\u8981\u7d20\u3067\u3059\u3002\u305d\u306e\u4e2d\u3067\u3082\u3001\u6e29\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25000,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nalgene-safety-control-lpd-26013\/","url_meta":{"origin":1390,"position":5},"title":"\u30e9\u30dc\u30dc\u30c8\u30eb\u306e\u8010\u85ac\u54c1\u6027\u3068\u6c17\u5bc6\u6027\u3068\u306f\uff1f\uff5e \u610f\u5916\u3068\u77e5\u3089\u306a\u3044\u57fa\u672c\u306e\u8a71\uff5e","author":"LatB Staff","date":"2026\u5e743\u670826\u65e5","format":false,"excerpt":"\u30dc\u30c8\u30eb\u9078\u3073\u3001\u306a\u3093\u3068\u306a\u304f\u3067\u5927\u4e08\u592b\uff1f \u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30dc\u30c8\u30eb\u306f\u3001\u30dc\u30c8\u30eb\u306e\u6a39\u8102\u3068\u5185\u5bb9\u7269\u306e\u76f8\u6027\u304c\u9069\u5207\u3067\u306a\u3044\u5834\u5408\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/isq-7000-trace-1310-triplus-rsh-left-1200x1200-650.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1390","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1390"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1390\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/4814"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1390"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1390"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1390"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1390"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}