{"id":1418,"date":"2018-09-30T00:00:00","date_gmt":"2018-09-29T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/"},"modified":"2025-02-27T16:28:09","modified_gmt":"2025-02-27T07:28:09","slug":"user_voice_45_4_ibright","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/","title":{"rendered":"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09"},"content":{"rendered":"<h2 style=\"text-align: left\"><span style=\"font-size: 12pt\"><strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u306e\u7d50\u5408\u80fd\u3092iBright FL1000 Imaging System\u3067\u52b9\u7387\u7684\u306b\u8a55\u4fa1<\/strong><\/span><\/h2>\n<p><strong>\u516b\u6728\u7950\u4ecb\u6c0f\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580\u90e8\u9577\uff09<\/strong><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/66c19942ab4ba346fdb64ccc04cde373-9-2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-4513\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/66c19942ab4ba346fdb64ccc04cde373-9-2.jpg\" alt=\"\u516b\u6728\u7950\u4ecb\u6c0f\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580\u90e8\u9577\uff09\" width=\"250\" height=\"168\" \/><\/a>\u690d\u7269\u306e\u8449\u7dd1\u4f53\u3084\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u30b2\u30ce\u30e0\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u3092RNA\u30ec\u30d9\u30eb\u3067\u5236\u5fa1\u3059\u308b\u56e0\u5b50\u3068\u3057\u3066\u3001\u6ce8\u76ee\u3055\u308c\u308bPPR\uff08pentatricopeptide repeat\uff09\u30bf\u30f3\u30d1\u30af\u8cea\u3002\u9ad8\u7b49\u690d\u7269\u3067\u306f\u7d04500\u7a2e\u985e\u306b\u53ca\u3076\u30d5\u30a1\u30df\u30ea\u30fc\u304c\u5b58\u5728\u3057\u3001\u914d\u5217\u7279\u7570\u7684\u306bRNA\u306b\u7d50\u5408\u3057\u3066RNA\u5207\u65ad\u3084\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u3001\u7de8\u96c6\u3001\u5b89\u5b9a\u5316\u3001\u7ffb\u8a33\u306a\u3069\u306e\u591a\u69d8\u306a\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\u3092\u8abf\u7bc0\u3059\u308b\u3053\u3068\u304b\u3089\u3001\u30aa\u30eb\u30ac\u30cd\u30e9\u907a\u4f1d\u5b50\u7279\u7570\u7684\u306aRNA\u6a5f\u80fd\u8abf\u7bc0\u56e0\u5b50\u3068\u8003\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580\u306e\u516b\u6728\u7950\u4ecb\u6c0f\u3089\u306f\u3001PPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30d9\u30fc\u30b9\u306b\u3001\u3053\u308c\u307e\u3067\u306b\u306a\u3044\u300cRNA\u64cd\u4f5c\u300d\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3092\u9032\u3081\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2><span style=\"font-size: 12pt\">\u914d\u5217\u7279\u7570\u7684\u306bRNA\u306b\u7d50\u5408\u3059\u308bPPR\u30e2\u30c1\u30fc\u30d5<\/span><\/h2>\n<p>PPR\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u300135\u500b\u306e\u30a2\u30df\u30ce\u9178\u304b\u3089\u306a\u308bhelix-loop-helix\u69cb\u9020\uff08PPR\u30e2\u30c1\u30fc\u30d5\uff09\u304c\u5341\u6570\u56de\u7e70\u308a\u8fd4\u3057\u3001\u3053\u306e\u30e2\u30c1\u30fc\u30d5\u306e1\u3064\u304c\u7279\u5b9a\u306eRNA1\u5869\u57fa\u306b\u5bfe\u5fdc\u3057\u3066\u7d50\u5408\u3057\u307e\u3059\u30022012\u5e74\u3001\u4e5d\u5dde\u5927\u5b66\u8fb2\u5b66\u7814\u7a76\u9662\u690d\u7269\u5206\u5b50\u6a5f\u80fd\u5b66\u51c6\u6559\u6388\u306e\u4e2d\u6751\u5d07\u88d5\u6c0f\uff08\u73fe\u5728\u306f\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u793e\u9577\u3092\u517c\u4efb\uff09\u3068\u5f53\u6642\u30dd\u30b9\u30c9\u30af\u3060\u3063\u305f\u516b\u6728\u6c0f\u306f\u3001PPR\u30e2\u30c1\u30fc\u30d5\u5185\u306e3\u30ab\u6240\u306e\u30a2\u30df\u30ce\u9178\u304c1\u3064\u306e\u5869\u57fa\u3092\u8a8d\u8b58\u3059\u308b\u5bfe\u5fdc\u30eb\u30fc\u30eb\u3092\u660e\u3089\u304b\u306b\u3057\u307e\u3057\u305f\u3002\u300c\u3053\u306e\u30eb\u30fc\u30eb\u3092\u57fa\u306b\u3001\u6a19\u7684\u3068\u306a\u308bRNA\u914d\u5217\u306b\u7d50\u5408\u3059\u308bPPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u4f5c\u6210\u3057\u3001\u305d\u3053\u306b\u6a5f\u80fd\u5206\u5b50\u3092\u4ed8\u52a0\u3057\u3066\u304a\u3051\u3070\u30b2\u30ce\u30e0\u7de8\u96c6\u306e\u69d8\u306bRNA\u3092\u81ea\u5728\u306b\u64cd\u4f5c\u3067\u304d\u308b\u306f\u305a\u300d\u3068\u516b\u6728\u6c0f\u306f\u958b\u767a\u306e\u65b9\u5411\u6027\u3092\u8a9e\u308a\u307e\u3059\u3002<\/p>\n<h2><span style=\"font-size: 12pt\">PPR\u30bf\u30f3\u30d1\u30af\u8cea\u3068RNA\u7d50\u5408\u80fd\u3092\u86cd\u5149\u3067\u8a55\u4fa1<\/span><\/h2>\n<p>\u300cPPR\u30bf\u30f3\u30d1\u30af\u8cea\u3068RNA\u306e\u914d\u5217\u7279\u7570\u7684\u306a\u7d50\u5408\u80fd\u306e\u89e3\u6790\u306f\u30b2\u30eb\u30b7\u30d5\u30c8\u30a2\u30c3\u30bb\u30a4\u3067\u884c\u3063\u3066\u3044\u307e\u3059\u3002\u86cd\u5149\u30e9\u30d9\u30eb\u3057\u305f\u5408\u6210RNA\u3068PPR\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u8907\u5408\u4f53\u3092\u30cd\u30a4\u30c6\u30a3\u30d6\u30b2\u30eb\u3067\u96fb\u6c17\u6cf3\u52d5\u5f8c\u3001iBright\u2122 FL1000 Imaging System\u306e\u86cd\u5149\u30c1\u30e3\u30f3\u30cd\u30eb\u3067\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u4ee5\u524d\u306f\u30d3\u30aa\u30c1\u30f3\u30e9\u30d9\u30eb\u3057\u305fRNA\u3092\u4f7f\u3063\u3066\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5f8c\u306b\u5316\u5b66\u767a\u5149\u8a66\u85ac\u3067\u691c\u51fa\u3057\u3066\u3044\u307e\u3057\u305f\u304c\u3001iBright FL\u30b7\u30b9\u30c6\u30e0\u3060\u3068\u6cf3\u52d5\u5f8c\u306e\u30b2\u30eb\u3092\u76f4\u63a5\u6e2c\u5b9a\u3067\u304d\u3001\u6e2c\u5b9a\u3092\u7c21\u4fbf\u5316\u3067\u304d\u307e\u3057\u305f\u3002\u307e\u305f\u3053\u306e\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u8907\u6570\u306e\u86cd\u5149\u8272\u3092\u4f7f\u3048\u308b\u306e\u3067\u3001\u7570\u306a\u308bRNA\u914d\u5217\u3078\u306e\u7d50\u5408\u80fd\u3092\u4e00\u5ea6\u306b\u8a55\u4fa1\u3067\u304d\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u611f\u5ea6\u3082\u4ee5\u524d\u306e\u65b9\u6cd5\u3068\u5909\u308f\u308a\u306a\u304f\u3001\u6570nM\u7a0b\u5ea6\u306e\u7d50\u5408\u6d3b\u6027\u3082\u691c\u51fa\u3067\u304d\u3066\u3044\u307e\u3059\u300d\u3068\u516b\u6728\u6c0f\u306f\u8a9e\u308a\u307e\u3059\u3002\u300c\u30b7\u30b9\u30c6\u30e0\u81ea\u8eab\u306e\u64cd\u4f5c\u6027\u3082\u826f\u304f\u3001\u30bf\u30c3\u30c1\u30d1\u30cd\u30eb\u3067\u9732\u5149\u6642\u9593\u3092\u7c21\u5358\u306b\u8abf\u7bc0\u3067\u304d\u305f\u308a\u3001Smart Exposure\u6a5f\u80fd\u3067\u6700\u9069\u306a\u9732\u5149\u6642\u9593\u3092\u30d0\u30fc\u30c1\u30e3\u30eb\u306b\u78ba\u8a8d\u3067\u304d\u308b\u306e\u3082\u4fbf\u5229\u3067\u3059\u3002\u307e\u305f\u30b2\u30eb\u306e\u4f4d\u7f6e\u3092\u81ea\u52d5\u56de\u8ee2\u5f0f\u30b9\u30c6\u30fc\u30b8\u3067\u7269\u7406\u7684\u306b\u8abf\u6574\u3067\u304d\u308b\u306e\u3067\u3001\u7f6e\u304d\u66ff\u3048\u306e\u624b\u9593\u3082\u7701\u3051\u307e\u3059\u300d\u3068\u8a71\u3057\u307e\u3059\u3002<\/p>\n<h2><span style=\"font-size: 12pt\">PPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u7528\u3044\u3066RNA\u3092\u64cd\u4f5c\u3059\u308b<\/span><\/h2>\n<p>\u690d\u7269\u3067\u306f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u30b2\u30ce\u30e0\u304b\u3089\u8ee2\u5199\u3055\u308c\u305fRNA\u306bPPR\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u7d50\u5408\u3059\u308b\u3068\u3001RNA\u306e\u30b7\u30c8\u30b7\u30f3\u304c\u8131\u30a2\u30df\u30ce\u5316\u3055\u308c\u3066\u30a6\u30e9\u30b7\u30eb\u306b\u5909\u308f\u308bRNA\u7de8\u96c6\u304c\u89b3\u5bdf\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u516b\u6728\u6c0f\u3089\u304c\u63d0\u6848\u3059\u308b\u300cRNA\u64cd\u4f5c\u300d\u306f\u3001\u4e00\u5869\u57fa\u7f6e\u63db\u3060\u3051\u3067\u306a\u304f\u3001\u69d8\u3005\u306a\u6a5f\u80fd\u5206\u5b50\u3068\u306e\u878d\u5408\u306b\u3088\u308aRNA\u3092\u81ea\u5728\u306b\u7de8\u96c6\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u300c\u3053\u308c\u307e\u3067RNA\u306e\u6a5f\u80fd\u5236\u5fa1\u306fRNAi\u3084\u30a2\u30f3\u30c1\u30bb\u30f3\u30b9\u306a\u3069\u306e\u6838\u9178\u304c\u4f7f\u308f\u308c\u3001\u6a5f\u80fd\u6291\u5236\u3084FISH\u6cd5\u306a\u3069\u3068\u7528\u9014\u304c\u9650\u3089\u308c\u3066\u3044\u307e\u3057\u305f\u3002PPR\u30bf\u30f3\u30d1\u30af\u8cea\u306a\u3089\u3001\u69d8\u3005\u306a\u6a5f\u80fd\u5206\u5b50\u3068\u878d\u5408\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070GFP\u3092\u7e4b\u3052\u3066mRNA\u3084\u30ce\u30f3\u30b3\u30fc\u30c7\u30a3\u30f3\u30b0RNA\u306e\u7d30\u80de\u5185\u306e\u5c40\u5728\u3084\u6a5f\u80fd\u89e3\u6790\u306a\u3069\u3001\u3053\u308c\u307e\u3067\u306b\u306a\u3044\u30c4\u30fc\u30eb\u3068\u3057\u3066\u4f7f\u3048\u305d\u3046\u3067\u3059\u3002\u3055\u3089\u306b\u6a19\u7684RNA\u306e\u5207\u65ad\u3084\u30b9\u30d7\u30e9\u30a4\u30b7\u30f3\u30b0\u5236\u5fa1\u3001\u5869\u57fa\u7f6e\u63db\u3001\u767a\u73fe\u4ea2\u9032\u306a\u3069\u53ef\u80fd\u6027\u304c\u5e83\u304c\u308a\u307e\u3059\u3002DNA\u3092\u64cd\u4f5c\u3059\u308b\u30b2\u30ce\u30e0\u7de8\u96c6\u304c\u6ce8\u76ee\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001RNA\u64cd\u4f5c\u3082\u53ef\u80fd\u306b\u306a\u308c\u3070\u3001\u57fa\u790e\u7814\u7a76\u306f\u3082\u3068\u3088\u308a\u3001\u533b\u7642\u3084\u7523\u696d\u306b\u5f79\u7acb\u3064\u753b\u671f\u7684\u306a\u30c4\u30fc\u30eb\u3068\u306a\u308b\u3068\u601d\u3063\u3066\u3044\u307e\u3059\u300d\u3068\u516b\u6728\u6c0f\u306f\u4eca\u5f8c\u306e\u5c55\u958b\u3092\u8a9e\u308a\u307e\u3059\u3002<\/p>\n<h2><span style=\"font-size: 12pt\">\u64ae\u308a\u76f4\u3057\u4e0d\u8981!\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\u306e\u64ae\u5f71\u306f\u307e\u3059\u307e\u3059\u7c21\u5358\u306b<\/span><br \/>\n<span style=\"font-size: 12pt\">iBright CL1000 Imaging System \uff5c iBright FL1000 Imaging System<\/span><\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-assays-analysis\/western-blotting\/detect-proteins-western-blot\/western-blot-imaging-analysis\/ibright-western-blot-imaging-systems.html?CID=bid_pca_ibt_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa3n_Social_LAB\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4269 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/6144d20be82fa253b6bcc4c87b090ade.jpg\" alt=\"iBright CL1000 Imaging System \uff5c iBright FL1000 Imaging System\" width=\"150\" height=\"222\" \/><\/a>Invitrogen\u2122 iBright\u2122 Imaging Systems\u306f\u3001\u64ae\u5f71\u30b5\u30f3\u30d7\u30eb\u306e\u4f4d\u7f6e\u3084\u30d5\u30a9\u30fc\u30ab\u30b9\u30fb\u30ba\u30fc\u30e0\u3060\u3051\u3067\u306a\u304f\u3001\u6700\u9069\u306a\u9732\u5149\u6642\u9593\u3092\u81ea\u52d5\u8abf\u6574\u3059\u308b\u4fbf\u5229\u306a\u64ae\u5f71\u88c5\u7f6e\u3067\u3059\u3002\u5316\u5b66\u767a\u5149\u3001\u53ef\u8996\u5149\u3001UV\u64ae\u5f71\u7528\u306eiBright CL1000 Imaging System\u3001\u3055\u3089\u306b\u86cd\u5149\u64ae\u5f71\u306b\u3082\u5bfe\u5fdc\u3059\u308biBright FL1000 Imaging System \u306e2\u6a5f\u7a2e\u3092\u63d0\u4f9b\u4e2d\u3067\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-assays-analysis\/western-blotting\/detect-proteins-western-blot\/western-blot-imaging-analysis\/ibright-systems.html?CID=bid_pca_ibt_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa3n_Social_LAB\" target=\"_blank\" rel=\"noopener\">iBright CL1000 Imaging System \uff5c iBright FL1000 Imaging System\u306e\u8a73\u7d30\u60c5\u5831\u306f\u3053\u3061\u3089\u304b\u3089<\/a><\/p>\n<h2><span style=\"font-size: 12pt\">\u30e9\u30a4\u30d5\u30b5\u30a4\u30a8\u30f3\u30b9\u60c5\u5831\u8a8c\u300cNEXT\u300d<\/span><\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/communities-social\/NEXT-Forum\/next\/next-backnumber.html?CID=bid_pca_ibt_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa3n_Social_LAB\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft size-full wp-image-3422\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/foregroundimg.img_.full_.high-1-1-5.png\" alt=\"\" width=\"167\" height=\"235\" \/><\/a>\u5f53\u8a18\u4e8b\u306f\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u304c\u767a\u520a\u3059\u308b\u30e9\u30a4\u30d5\u30b5\u30a4\u30a8\u30f3\u30b9\u60c5\u5831\u8a8c\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u304b\u3089\u306e\u629c\u7c8b\u3067\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/communities-social\/NEXT-Forum\/next\/next-backnumber.html?CID=bid_pca_ibt_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa3n_Social_LAB\" target=\"_blank\" rel=\"noopener\">NEXT\u306e\u30d0\u30c3\u30af\u30ca\u30f3\u30d0\u30fc\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u306e\u7d50\u5408\u80fd\u3092iBright FL1000 Imaging System\u3067\u52b9\u7387\u7684\u306b\u8a55\u4fa1 \u516b\u6728\u7950\u4ecb\u6c0f\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580\u90e8\u9577\uff09 \u690d\u7269\u306e\u8449\u7dd1\u4f53\u3084\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u30b2\u30ce\u30e0\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u3092RNA\u30ec\u30d9\u30eb\u3067\u5236\u5fa1<\/p>\n","protected":false},"author":988,"featured_media":4864,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[158],"tags":[17,94],"division":[],"class_list":{"0":"post-1418","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-interview","8":"tag-western-blotting","9":"tag-user-voice","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09\" \/>\n<meta property=\"og:description\" content=\"\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u306e\u7d50\u5408\u80fd\u3092iBright FL1000 Imaging System\u3067\u52b9\u7387\u7684\u306b\u8a55\u4fa1 \u516b\u6728\u7950\u4ecb\u6c0f\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580\u90e8\u9577\uff09 \u690d\u7269\u306e\u8449\u7dd1\u4f53\u3084\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u30b2\u30ce\u30e0\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u3092RNA\u30ec\u30d9\u30eb\u3067\u5236\u5fa1\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-09-29T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-27T07:28:09+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09\",\"datePublished\":\"2018-09-29T15:00:00+00:00\",\"dateModified\":\"2025-02-27T07:28:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/\"},\"wordCount\":97,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/3985c22345862a51191f2cff7b54dbb4.jpg\",\"keywords\":[\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\",\"\u304a\u5ba2\u69d8\u306e\u58f0\"],\"articleSection\":[\"\u7814\u7a76\u8005\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/\",\"name\":\"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/3985c22345862a51191f2cff7b54dbb4.jpg\",\"datePublished\":\"2018-09-29T15:00:00+00:00\",\"dateModified\":\"2025-02-27T07:28:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/3985c22345862a51191f2cff7b54dbb4.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/3985c22345862a51191f2cff7b54dbb4.jpg\",\"width\":1200,\"height\":630},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/user_voice_45_4_ibright\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/","og_locale":"ja_JP","og_type":"article","og_title":"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09","og_description":"\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u306e\u7d50\u5408\u80fd\u3092iBright FL1000 Imaging System\u3067\u52b9\u7387\u7684\u306b\u8a55\u4fa1 \u516b\u6728\u7950\u4ecb\u6c0f\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580\u90e8\u9577\uff09 \u690d\u7269\u306e\u8449\u7dd1\u4f53\u3084\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u30b2\u30ce\u30e0\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u3092RNA\u30ec\u30d9\u30eb\u3067\u5236\u5fa1","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-09-29T15:00:00+00:00","article_modified_time":"2025-02-27T07:28:09+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09","datePublished":"2018-09-29T15:00:00+00:00","dateModified":"2025-02-27T07:28:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/"},"wordCount":97,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4.jpg","keywords":["\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0","\u304a\u5ba2\u69d8\u306e\u58f0"],"articleSection":["\u7814\u7a76\u8005\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/","name":"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4.jpg","datePublished":"2018-09-29T15:00:00+00:00","dateModified":"2025-02-27T07:28:09+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4.jpg","width":1200,"height":630},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/user_voice_45_4_ibright\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u690d\u7269\u306ePPR\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d3b\u7528\u3057\u3001\u9769\u65b0\u7684\u306aRNA\u64cd\u4f5c\u30c4\u30fc\u30eb\u306e\u958b\u767a\u3078\uff08\u30a8\u30c7\u30a3\u30c3\u30c8\u30d5\u30a9\u30fc\u30b9\u682a\u5f0f\u4f1a\u793e\u7814\u7a76\u958b\u767a\u90e8\u9580 \u516b\u6728\u7950\u4ecb\u6c0f\uff09-\u300cNEXT\u300d2018\u5e745\u6708\u53f7\u63b2\u8f09"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":158,"label":"\u7814\u7a76\u8005\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc"}],"post_tag":[{"value":17,"label":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0"},{"value":94,"label":"\u304a\u5ba2\u69d8\u306e\u58f0"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":158,"name":"\u7814\u7a76\u8005\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc","slug":"interview","term_group":0,"term_taxonomy_id":158,"taxonomy":"category","description":"","parent":0,"count":66,"filter":"raw","meta":[],"cat_ID":158,"category_count":66,"category_description":"","cat_name":"\u7814\u7a76\u8005\u30a4\u30f3\u30bf\u30d3\u30e5\u30fc","category_nicename":"interview","category_parent":0}],"tag_info":[{"term_id":17,"name":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0","slug":"western-blotting","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":27,"filter":"raw","meta":[]},{"term_id":94,"name":"\u304a\u5ba2\u69d8\u306e\u58f0","slug":"user-voice","term_group":0,"term_taxonomy_id":94,"taxonomy":"post_tag","description":"","parent":0,"count":61,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":1418,"position":0},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":1418,"position":1},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23239,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-bfx-25060\/","url_meta":{"origin":1418,"position":2},"title":"\u98df\u54c1\u958b\u767a\u306b\u304a\u3051\u308b\u83cc\u53e2\u89e3\u6790\u3068\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u306e\u6d3b\u7528","author":"LatB Staff","date":"2025\u5e7410\u67088\u65e5","format":false,"excerpt":"\u907a\u4f1d\u5b50\u95a2\u9023\u306e\u89e3\u6790\u6280\u8853\u304c\u7814\u7a76\u306e\u307f\u306a\u3089\u305a\u7523\u696d\u5206\u91ce\u3067\u6d3b\u7528\u3055\u308c\u308b\u3088\u3046\u306b\u306a\u308a\u3001\u5e74\u6708\u304c\u7d4c\u904e\u3059\u308b\u306b\u3064\u308c\u3066\u5fdc\u7528\u7bc4\u56f2\u3082\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/ngs-gene-expression-gsd-ts-tr-25060_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068_\/","url_meta":{"origin":1418,"position":3},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-nucleic-acid-purification-ts-r-25017\/","url_meta":{"origin":1418,"position":4},"title":"\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790","author":"LatB Staff","date":"2026\u5e745\u670813\u65e5","format":false,"excerpt":"\u7b2c2\u56de\u3067\u306f\u3001\u57f9\u990a\u4e0a\u6e05\u3084\u3055\u307e\u3056\u307e\u306a\u4f53\u6db2\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u65b9\u6cd5\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/f17931341a23d82235760ed66ded9c41.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":1418,"position":5},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/3985c22345862a51191f2cff7b54dbb4.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1418","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1418"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1418\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/4864"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1418"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1418"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1418"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1418"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}