{"id":14429,"date":"2023-06-09T17:17:51","date_gmt":"2023-06-09T08:17:51","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=14429"},"modified":"2023-06-09T17:17:51","modified_gmt":"2023-06-09T08:17:51","slug":"cancer-microarray-gsd-ts-1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/","title":{"rendered":"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e"},"content":{"rendered":"<h2>\u67d3\u8272\u4f53\u7570\u5e38\u306e\u771f\u306e\u59ff\u3092\u898b\u3064\u3051\u308b<\/h2>\n<p>\u816b\u760d\u5b66\u306f\u3001\u8907\u96d1\u306a\u67d3\u8272\u4f53\u7570\u5e38\u3068\u6700\u3082\u6df1\u304f\u95a2\u308f\u308b\u533b\u5b66\u306e\u4e00\u5206\u91ce\u3068\u8a00\u3048\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u304c\u3093\u3067\u306f\u3001DNA\u4fee\u5fa9\u6a5f\u69cb\u306e\u7834\u7dbb\u3084\u7a81\u7136\u5909\u7570\u306e\u84c4\u7a4d\u306b\u3088\u3063\u3066\u6b63\u78ba\u306b\u539f\u56e0\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u306a\u8907\u6570\u306e\u7570\u5e38\u304c\u5f15\u304d\u8d77\u3053\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u305d\u308c\u305e\u308c\u304c\u3093\u306e\u6027\u683c\u3068\u305d\u306e\u6027\u8cea\u3092\u6b63\u78ba\u306b\u628a\u63e1\u3057\u6cbb\u7642\u3059\u308b\u3053\u3068\u3092\u56f0\u96e3\u306b\u3057\u307e\u3059\u3002\u67d3\u8272\u4f53\u7570\u5e38\u306e\u771f\u306e\u59ff\u3092\u660e\u3089\u304b\u306b\u3059\u308b\u6642\u3001\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\uff08CMA\uff09\u306e\u529b\u3092\u8d85\u3048\u308b\u6280\u8853\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u30ce\u30fc\u30b9\u30a6\u30a7\u30b9\u30bf\u30f3\u5927\u5b66\u30d5\u30a1\u30a4\u30f3\u30d0\u30fc\u30b0\u533b\u5b66\u90e8\u3001\u75c5\u7406\u5b66\u52a9\u6559\u6388\u306eMadina Sukhanova\u535a\u58eb\u306f\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3092\u7528\u3044\u3066\u3001\u816b\u760d\u5b66\u306e\u96e3\u89e3\u306a\u75c7\u4f8b\u3092\u89e3\u6c7a\u3057\u305f\u4e8b\u4f8b\u3092\u4e0b\u8a18\u306e\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc\u3067\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/life-science\/cma-oncology-webinar.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_cancer_microarray_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Application of Chromosomal Microarray Analysis in Oncology.<\/a><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-14430\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/29d3bc99193cb0b837fb8cc53f050ae5-1.jpg\" alt=\"Webinar: Application of Chromosomal Microarray Analysis in Oncology Research\" width=\"430\" height=\"275\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/29d3bc99193cb0b837fb8cc53f050ae5-1.jpg 430w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/29d3bc99193cb0b837fb8cc53f050ae5-1-300x192.jpg 300w\" sizes=\"auto, (max-width: 430px) 100vw, 430px\" \/><\/p>\n<h2>\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4(CMAs)\u306e\u529b\u3068\u5206\u89e3\u80fd<\/h2>\n<p><strong>\u816b\u760d\u3068\u306e\u95a2\u308f\u308a<\/strong><br \/>\n\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u30d1\u30ef\u30fc\u3068\u89e3\u50cf\u5ea6\u306f\u6700\u3082\u56f0\u96e3\u306a\u30b1\u30fc\u30b9\u3067\u6700\u5927\u9650\u306b\u767a\u63ee\u3055\u308c\u308b\u3068Sukhanova\u535a\u58eb\u306f\u78ba\u4fe1\u3057\u3066\u3044\u307e\u3059\u3002\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u6b63\u78ba\u306a\u816b\u760d\u30b5\u30d6\u30af\u30e9\u30b9\u306e\u6c7a\u5b9a\u3001\u816b\u760d\u30ea\u30b9\u30af\u306e\u5c64\u5225\u5316\u3001\u816b\u760d\u306e\u90e8\u4f4d\u3084\u9032\u884c\u5ea6\u306e\u9055\u3044\u306b\u3088\u308b\u76f8\u5bfe\u7684\u5371\u967a\u5ea6\u306e\u8a55\u4fa1\u3001\u305d\u3057\u3066\u57f9\u990a\u5931\u6557\u30fb\u5897\u6b96\u304c\u9045\u3044\u816b\u760d\u7d44\u7e54\u30fb\u30db\u30eb\u30de\u30ea\u30f3\u56fa\u5b9a\u30d1\u30e9\u30d5\u30a3\u30f3\u5305\u57cb\uff08FFPE\uff09\u30b5\u30f3\u30d7\u30eb\u306e\u3088\u3046\u306a\u6700\u9069\u3067\u306a\u3044\u8a66\u6599\u3092\u6271\u3046\u306e\u306b\u7406\u60f3\u7684\u3067\u3059\u3002<\/p>\n<p><strong>\u85ac\u306e\u63a2\u7d22<\/strong><br \/>\n\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u591a\u6570\u306e\u6d3b\u6027\u90e8\u4f4d\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u5275\u85ac\u306e\u7814\u7a76\u306b\u3082\u6709\u7528\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u72b6\u6cc1\u3067\u306f\u3001\u304c\u3093\u7814\u7a76\u306e\u4e3b\u8981\u306a\u30c4\u30fc\u30eb\u3067\u3042\u308b\u5927\u898f\u6a21\u306a\u86cd\u5149in situ\u30cf\u30a4\u30d6\u30ea\u30c0\u30a4\u30bc\u30fc\u30b7\u30e7\u30f3\uff08FISH\uff09\u30d1\u30cd\u30eb\u3068\u306e\u4f75\u7528\u3001\u3042\u308b\u3044\u306f\u305d\u308c\u306b\u53d6\u3063\u3066\u4ee3\u308f\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><strong>\u67d3\u8272\u4f53\u7570\u5e38\u306e\u691c\u51fa\u3068\u7279\u6027\u8a55\u4fa1<\/strong><br \/>\n\u816b\u760d\u5b66\u306b\u304a\u3051\u308b\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u5fae\u5c0f\u306a\u6b20\u5931\u3084\u91cd\u8907\u306e\u691c\u51fa\u3001\u30b3\u30d4\u30fc\u30cb\u30e5\u30fc\u30c8\u30e9\u30eb\u306a\u30d8\u30c6\u30ed\u63a5\u5408\u6027\u55aa\u5931\uff08CN-LOH\uff09\u306e\u691c\u51fa\u3001\u8840\u6db2\u5b66\u7684\u60aa\u6027\u816b\u760d\u306e\u67d3\u8272\u4f53\u7570\u5e38\u306e\u7279\u5fb4\u4ed8\u3051\u306b\u5f79\u7acb\u3063\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306fDNA\u4fee\u5fa9\u6a5f\u69cb\u304c\u6a5f\u80fd\u305b\u305a\u4ed6\u306e\u691c\u51fa\u65b9\u6cd5\u3067\u306f\u89e3\u91c8\u3067\u304d\u306a\u3044\u307b\u3069\u591a\u304f\u306e\u65ad\u7247\u306b\u67d3\u8272\u4f53\u304c\u5207\u65ad\u3055\u308c\u308b\u73fe\u8c61\u3067\u3042\u308b\u67d3\u8272\u4f53\u7834\u7815\u306e\u7814\u7a76\u306b\u3082\u9069\u3057\u305f\u30c4\u30fc\u30eb\u306e\uff11\u3064\u3067\u3059\u3002<\/p>\n<p>Sukhanova\u535a\u58eb\u306f\u6b21\u306e\uff14\u3064\u306e\u4e8b\u4f8b\u3067\u305d\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u8aac\u660e\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<ol>\n<li>\uff11\u3064\u76ee\u306e\u4e8b\u4f8b\u306f\u3001\u904e\u53bb\u306b\u7d4c\u9a13\u3057\u305f\u5f62\u8cea\u7d30\u80de\u9aa8\u9ac4\u816b\u306b\u95a2\u9023\u3059\u308bB\u7d30\u80de\u6027\u6025\u6027\u30ea\u30f3\u30d1\u82bd\u7403\u6027\u767d\u8840\u75c5\u3068\u30ea\u30f3\u30d1\u816b\u3092\u60a3\u3063\u3066\u3044\u308b49\u6b73\u306e\u5973\u6027\u3067\u3059\u3002\u5f7c\u5973\u306e\u6838\u578b\u304b\u3089\u3001\u5f7c\u5973\u306e\u304c\u3093\u306f\u9ad82\u500d\u4f53\uff08\u907a\u4f1d\u5b50\u91cd\u8907\u4e8b\u8c61\u306b\u95a2\u9023\u3057\u305f\u307b\u307c\u5b8c\u5168\u306a4\u500d\u4f53\uff09\u3067\u3042\u308a\u3001\u4e88\u5f8c\u306f\u826f\u597d\u3067\u6cbb\u7642\u306e\u5fc5\u8981\u6027\u3082\u6bd4\u8f03\u7684\u8efd\u5ea6\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u3066\u3044\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u7814\u7a76\u306b\u3088\u3063\u3066\u9ad82\u500d\u4f53\u816b\u760d\u3068\u601d\u308f\u308c\u305f\u3082\u306e\u306f\u3001\u5b9f\u969b\u306f\u5b9f\u8cea\u7684\u306a\u67d3\u8272\u4f53\u55aa\u5931\u3092\u4f34\u3046\u4f4e2\u500d\u4f53\u816b\u760d\u304c\u3001\u305d\u306e\u5f8c\u307b\u307c\u5b8c\u5168\u306a\u907a\u4f1d\u5b50\u91cd\u8907\u30922\u56de\u7d4c\u9a13\u3057\u3001\u816b\u760d\u306e\u7570\u578b\u5ea6\u304c\u5287\u7684\u306b\u6e1b\u5c11\u3057\u3066\u67d3\u8272\u4f53\u6570\u304c69-XX\u306b\u306a\u3063\u305f\u3082\u306e\u3067\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u9ad82\u500d\u4f53\u30ea\u30f3\u30d1\u816b\u306f\u4e00\u822c\u7684\u306b\u4e88\u5f8c\u304c\u826f\u3044\u4e00\u65b9\u3067\u3001\u4f4e2\u500d\u4f53\u30ea\u30f3\u30d1\u816b\u306f\u6cbb\u7642\u304c\u96e3\u3057\u304f\u3001\u305d\u3057\u3066\u5f7c\u5973\u306e\u72b6\u614b\u306f\u524d\u8005\u3088\u308a\u3082\u5f8c\u8005\u3068\u306e\u907a\u4f1d\u7684\u306a\u5171\u901a\u70b9\u304c\u591a\u304f\u3042\u308a\u307e\u3057\u305f\u3002\u3053\u306e\u3053\u3068\u304b\u3089\u3001\u3053\u306e\u75c7\u4f8b\u306f\u5f53\u521d\u306e\u30ea\u30b9\u30af\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u304b\u3089\u63a8\u6e2c\u3055\u308c\u308b\u3088\u308a\u3082\u3001\u306f\u308b\u304b\u306b\u7a4d\u6975\u7684\u306a\u6cbb\u7642\u304c\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u305f\u306e\u3067\u3059\u3002<\/li>\n<li>2\u3064\u76ee\u306e\u4e8b\u4f8b\u306f\u3001\u4e73\u304c\u3093\u306e\u65e2\u5f80\u6b74\u304c\u3042\u308b 87\u6b73\u306e\u5973\u6027\u304c\u5f62\u8cea\u7d30\u80de\u6027\u9aa8\u9ac4\u816b\u3067\u518d\u5165\u9662\u3057\u305f\u30b1\u30fc\u30b9\u3067\u3059\u3002\u7814\u7a76\u306b\u5229\u7528\u3067\u304d\u308b\u60aa\u6027\u5f62\u8cea\u7d30\u80de\u306e\u6570\u304c\u975e\u5e38\u306b\u5c11\u306a\u3044\u305f\u3081\u3001FISH\u3068\u7d30\u80de\u907a\u4f1d\u5b66\u7684\u7814\u7a76\u3068\u4e26\u884c\u3057\u3066\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u304c\u5b9f\u65bd\u3055\u308c\u307e\u3057\u305f\u3002\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u89e3\u6790\u306e\u7d50\u679c\u3001\u3053\u306e\u75c7\u4f8b\u306e\u304c\u3093\u306e\u907a\u4f1d\u5b50\u578b\u306f\u975e\u5e38\u306b\u8907\u96d1\u3067\u3001\u591a\u6570\u306e\u67d3\u8272\u4f53\u306e\u6b20\u5931\u3084\u91cd\u8907\u3001\u591a\u304f\u306e\u67d3\u8272\u4f53\u90e8\u5206\u304c\u4ed6\u306e\u67d3\u8272\u4f53\u306b\u8ee2\u5ea7\u3057\u305f\u308a\u3001\u5b8c\u5168\u306b\u6b20\u843d\u3057\u305f\u308a\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5224\u660e\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u5178\u578b\u7684\u306a\u67d3\u8272\u4f53\u5206\u96e2\u75c7\u3067\u3042\u308a\u3001\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u308f\u305a\u304b\u306aFISH\u8ee2\u5ea7\u30d7\u30ed\u30fc\u30d6\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u30d5\u30ebFISH\u30d1\u30cd\u30eb\u306b\u4ee3\u308f\u3063\u3066\u52b9\u679c\u7684\u306b\u67d3\u8272\u4f53\u5206\u96e2\u75c7\u3092\u691c\u51fa\u3067\u304d\u308b\u3053\u3068\u3092\u5b9f\u8a3c\u3057\u305f\u4e8b\u4f8b\u3067\u3059\u3002<\/li>\n<li>3\u3064\u76ee\u306e\u4e8b\u4f8b\u306f\u751f\u5f8c23\u30ab\u6708\u306e\u7537\u5150\u3067\u3059\u3002\u5f7c\u306f\u5408\u4f75\u75c7\u306a\u304f\u6e80\u671f\u3067\u751f\u307e\u308c\u305f\u3082\u306e\u306e\u3001\u6301\u7d9a\u7684\u306a\u4e0a\u6c17\u9053\u611f\u67d3\u3068\u4e0d\u5b89\u5b9a\u306a\u6b69\u884c\u3001\u7e70\u308a\u8fd4\u3059\u982d\u90e8\u75db\u3001\u4e00\u4eba\u6b69\u304d\u3078\u306e\u6050\u6016\u306a\u3069\u306e\u7570\u5e38\u884c\u52d5\u304c\u307f\u3089\u308c\u307e\u3057\u305f\u3002CT\u30b9\u30ad\u30e3\u30f3\u306b\u3088\u3063\u3066\u982d\u84cb\u5185\u816b\u760d\u306e\u5b58\u5728\u304c\u660e\u3089\u304b\u306b\u306a\u308a\u3001\u90e8\u5206\u7684\u306b\u5207\u9664\u3055\u308c\u307e\u3057\u305f\u3002\u7d44\u7e54\u5b66\u7684\u306b\u306f\u9ac4\u819c\u816b\u304c\u793a\u5506\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u3053\u306e\u30bf\u30a4\u30d7\u306e\u304c\u3093\u306f\u5b9f\u969b\u306b\u306f\u5c0f\u5150\u306b\u306f\u307b\u3068\u3093\u3069\u898b\u3089\u308c\u306a\u3044\u3082\u306e\u3067\u3042\u308a\u3001\u8a3a\u65ad\u5e74\u9f62\u306e\u4e2d\u592e\u5024\u306f65\u6b73\u3068\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u816b\u760d\u3092\u5b8c\u5168\u306b\u53d6\u308a\u9664\u304f\u3053\u3068\u304c\u3067\u304d\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u7d30\u80de\u5b66\u7684\u306a\u624b\u6bb5\u3092\u7528\u3044\u3066\u3001\u816b\u760d\u306e\u4e16\u754c\u4fdd\u5065\u6a5f\u95a2\uff08WHO\uff09\u306e\u9ac4\u819c\u816b\u306e\u30b0\u30ec\u30fc\u30c9\u3092\u6c7a\u5b9a\u3059\u308b\u8a66\u307f\u304c\u306a\u3055\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308a\u300122\u756a\u67d3\u8272\u4f53\u306b\u7279\u7570\u7684\u306a\u6b20\u640d\u304c\u3042\u308b\u3053\u3068\u304c\u5224\u660e\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u60c5\u5831\u306f\u3053\u306e\u75c7\u4f8b\u306e\u4e88\u5f8c\u304c\u60aa\u3044\u3053\u3068\u3092\u660e\u3089\u304b\u306b\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n<li>Sukhanova\u535a\u58eb\u306e\u6700\u5f8c\u306e\u75c7\u4f8b\u306f\u3001\u91cd\u5927\u306a\u75c5\u6b74\u3092\u6301\u305f\u306a\u304423\u6b73\u306e\u5973\u6027\u3067\u3057\u305f\u3002\u5f7c\u5973\u306f\u5de6\u5927\u817f\u90e8\u306b\u5897\u5927\u3059\u308b\u816b\u7624\u3092\u5448\u3057\u3066\u3044\u307e\u3057\u305f\u3002MRI\u3067\u306f\u3001\u816b\u7624\u306f\u4e0d\u5747\u4e00\u3067\u3042\u308a\u3001\u60aa\u6027\u816b\u760d\u3092\u793a\u3059\u30b7\u30b0\u30ca\u30eb\u3082\u3042\u308a\u307e\u3057\u305f\u3002\u816b\u7624\u6458\u51fa\u5f8c\u306b\u6b8b\u5b58\u75c5\u5909\u306f\u306a\u304f\uff0c\u9855\u5fae\u93e1\u691c\u67fb\u3067\u306f\u4e88\u5f8c\u826f\u597d\u306a\u307e\u308c\u306a\u708e\u75c7\u6027\u5e73\u6ed1\u7b4b\u8089\u816b\uff0f\u7d44\u7e54\u7403\u304c\u8c4a\u5bcc\u306a\u6a2a\u7d0b\u7b4b\u8089\u816b\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u307e\u3057\u305f\u3002\u3088\u308a\u8a73\u3057\u3044\u60c5\u5831\u3092\u5f97\u308b\u305f\u3081\u306b\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u7814\u7a76\u304c\u884c\u308f\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u4ed6\u306e\u691c\u67fb\u3068\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308a\u3001\u3053\u306e\u304c\u3093\u306e\u30ab\u30c6\u30b4\u30ea\u30fc\u5168\u4f53\u3092\u518d\u8a8d\u8b58\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u518d\u5b9a\u7fa9\u3055\u308c\u305f\u300c\u708e\u75c7\u6027\u6a2a\u7d0b\u7b4b\u878d\u89e3\u6027\u816b\u760d\u300d\u306f\u3001\u5168\u30b2\u30ce\u30e0\u30b3\u30d4\u30fc\u6570\u8a55\u4fa1\u306b\u57fa\u3065\u3044\u3066\u533a\u5225\u3055\u308c\u308b2\u3064\u306e\u30b5\u30d6\u30bf\u30a4\u30d7\u304c\u3042\u308a\u3001\u307b\u307c\u534a\u6570\u4f53\uff085\u300112\u300118\u300120\u300121\u300122\u756a\u67d3\u8272\u4f53\u3092\u4fdd\u6301\uff09\u306e\u816b\u760d\u306f\u30015\u300120\u300122\u756a\u67d3\u8272\u4f53\u306e\u30b3\u30d4\u30fc\u30cb\u30e5\u30fc\u30c8\u30e9\u30eb\u306a\u30d8\u30c6\u30ed\u63a5\u5408\u6027\u306e\u55aa\u5931\u3092\u793a\u3059\u816b\u760d\u3088\u308a\u3082\u4e88\u5f8c\u3084\u884c\u52d5\u304c\u975e\u5e38\u306b\u60aa\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u3053\u306e2\u3064\u306e\u75be\u60a3\u306e\u30b5\u30d6\u30bf\u30a4\u30d7\u3092\u533a\u5225\u3059\u308b\u306e\u306b\u826f\u3044\u65b9\u6cd5\u3067\u3042\u308b\u3053\u3068\u304c\u8a3c\u660e\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u75c7\u4f8b\u3067\u306f\u524d\u8005\u306e\u30bf\u30a4\u30d7\u3067\u3042\u308b\u3053\u3068\u304c\u8a3c\u660e\u3055\u308c\u307e\u3057\u305f\u3002\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u3068\u514d\u75ab\u7d44\u7e54\u5316\u5b66\u3092\u4f75\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u4e00\u898b\u4f4e\u30ea\u30b9\u30af\u306b\u898b\u3048\u308b\u3053\u306e\u75c7\u4f8b\u304c\u5b9f\u306f\u304b\u306a\u308a\u9ad8\u30ea\u30b9\u30af\u3067\u3042\u308a\u3001\u5371\u967a\u306a\u518d\u767a\u3092\u9632\u3050\u305f\u3081\u306b\u9577\u671f\u306e\u5316\u5b66\u7642\u6cd5\u304c\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u305f\u306e\u3067\u3059\u3002<\/li>\n<\/ol>\n<p>\u95a2\u9023: <a href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/chromothripsis-a-new-frontier-in-cancer-research\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_cancer_microarray_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Chromothripsis: A New Frontier in Cancer Research<\/a><\/p>\n<h2>\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u7cbe\u5bc6\u306a\u67d3\u8272\u4f53\u7570\u5e38\u306b\u95a2\u3059\u308b\u30c7\u30fc\u30bf\u3092\u751f\u307f\u51fa\u3059<\/h2>\n<p>\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u4ed6\u306e\u65b9\u6cd5\u3067\u306f\u691c\u51fa\u304c\u96e3\u3057\u3044\u7cbe\u5bc6\u306a\u67d3\u8272\u4f53\u7570\u5e38\u306b\u95a2\u3059\u308b\u30c7\u30fc\u30bf\u3092\u751f\u307f\u51fa\u3059\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3067\u3042\u308a\u3001\u6349\u3048\u306b\u304f\u3044\u3082\u306e\u306e\u975e\u5e38\u306b\u610f\u5473\u306e\u3042\u308b\u304c\u3093\u306e\u30b5\u30d6\u30bf\u30a4\u30d7\u3092\u533a\u5225\u3059\u308b\u4f5c\u696d\u306b\u9069\u3057\u3066\u3044\u308b\u3068\u8a00\u3048\u307e\u3059\u3002\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306f\u3001\u816b\u760d\u3092\u6b63\u78ba\u306b\u5206\u985e\u3059\u308b\u305f\u3081\u306e\u91cd\u8981\u306a\u30c4\u30fc\u30eb\u30ad\u30c3\u30c8\u3067\u3042\u308a\u3001\u30ea\u30b9\u30af\u8a55\u4fa1\u306b\u6709\u52b9\u3067\u3042\u308a\u3001\u7570\u306a\u308b\u816b\u760d\u90e8\u4f4d\u306e\u907a\u4f1d\u5b50\u30b7\u30b0\u30cd\u30c1\u30e3\u30fc\u306e\u6bd4\u8f03\u5206\u6790\u306b\u5f79\u7acb\u3061\u3001\u816b\u760d\u306e\u81e8\u5e8a\u7814\u7a76\u306b\u512a\u308c\u3066\u3044\u308b\u3053\u3068\u306f\u660e\u3089\u304b\u3067\u3059\u3002<\/p>\n<h3><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/life-science\/cma-oncology-webinar.html?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_cancer_microarray_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u8996\u8074\u3059\u308b\uff1aApplication of Chromosomal Microarray Analysis in Oncology<\/a><\/h3>\n<p>Medina Sukhanova\u535a\u58eb\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u7a2e\u985e\u306e\u304c\u3093\u306b\u304a\u3051\u308b\u7279\u5b9a\u306e\u4e88\u5f8c\u3068\u95a2\u9023\u3059\u308b\u907a\u4f1d\u5b50\u7570\u5e38\u3092\u7279\u5b9a\u3059\u308b\u305f\u3081\u306b\u3001NGS\u30a2\u30c3\u30bb\u30a4\u3068\u7d44\u307f\u5408\u308f\u305b\u305f\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6709\u7528\u6027\u3092\u5b9f\u8a3c\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u8208\u5473\u6df1\u3044\u816b\u760d\u5b66\u306e\u75c7\u4f8b\u3084\u77e5\u898b\u3092\u8abf\u67fb\u3059\u308b\u65b9\u6cd5\u3092\u5b66\u3076\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n<li>\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u91cd\u8981\u6027\u3068\u3001\u816b\u760d\u5b66\u7684\u691c\u67fb\u306b\u304a\u3051\u308b\u91cd\u8981\u306a\u5f79\u5272\u306b\u3064\u3044\u3066\u306e\u77e5\u8b58\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n<li>NGS\u3068\u7d44\u307f\u5408\u308f\u305b\u305f\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306e\u6709\u7528\u6027\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n<p>\u539f\u6587\uff08\u82f1\u8a9e\u7248\uff09\u306f\u3053\u3061\u3089<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/behindthebench\/solving-oncology-cases-with-chromosomal-microarrays\/?CID=gsd_mic_gex_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_cancer_microarray_gsd_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/www.thermofisher.com\/blog\/behindthebench\/solving-oncology-cases-with-chromosomal-microarrays\/<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u67d3\u8272\u4f53\u7570\u5e38\u306e\u771f\u306e\u59ff\u3092\u898b\u3064\u3051\u308b \u816b\u760d\u5b66\u306f\u3001\u8907\u96d1\u306a\u67d3\u8272\u4f53\u7570\u5e38\u3068\u6700\u3082\u6df1\u304f\u95a2\u308f\u308b\u533b\u5b66\u306e\u4e00\u5206\u91ce\u3068\u8a00\u3048\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u304c\u3093\u3067\u306f\u3001DNA\u4fee\u5fa9\u6a5f\u69cb\u306e\u7834\u7dbb\u3084\u7a81\u7136\u5909\u7570\u306e\u84c4\u7a4d\u306b\u3088\u3063\u3066\u6b63\u78ba\u306b\u539f\u56e0\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u306a\u8907\u6570\u306e\u7570\u5e38\u304c\u5f15\u304d\u8d77\u3053\u3055\u308c\u3066<\/p>\n","protected":false},"author":975,"featured_media":14455,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[71],"division":[],"class_list":["post-14429","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-microarray","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e\" \/>\n<meta property=\"og:description\" content=\"\u67d3\u8272\u4f53\u7570\u5e38\u306e\u771f\u306e\u59ff\u3092\u898b\u3064\u3051\u308b \u816b\u760d\u5b66\u306f\u3001\u8907\u96d1\u306a\u67d3\u8272\u4f53\u7570\u5e38\u3068\u6700\u3082\u6df1\u304f\u95a2\u308f\u308b\u533b\u5b66\u306e\u4e00\u5206\u91ce\u3068\u8a00\u3048\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u304c\u3093\u3067\u306f\u3001DNA\u4fee\u5fa9\u6a5f\u69cb\u306e\u7834\u7dbb\u3084\u7a81\u7136\u5909\u7570\u306e\u84c4\u7a4d\u306b\u3088\u3063\u3066\u6b63\u78ba\u306b\u539f\u56e0\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u306a\u8907\u6570\u306e\u7570\u5e38\u304c\u5f15\u304d\u8d77\u3053\u3055\u308c\u3066\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-06-09T08:17:51+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"350\" \/>\n\t<meta property=\"og:image:height\" content=\"216\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"9\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e\",\"datePublished\":\"2023-06-09T08:17:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/\"},\"wordCount\":55,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/cancer-microarray-gsd-ts-1-eyecatch.jpg\",\"keywords\":[\"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/\",\"name\":\"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/cancer-microarray-gsd-ts-1-eyecatch.jpg\",\"datePublished\":\"2023-06-09T08:17:51+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/cancer-microarray-gsd-ts-1-eyecatch.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/cancer-microarray-gsd-ts-1-eyecatch.jpg\",\"width\":350,\"height\":216},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cancer-microarray-gsd-ts-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e","og_description":"\u67d3\u8272\u4f53\u7570\u5e38\u306e\u771f\u306e\u59ff\u3092\u898b\u3064\u3051\u308b \u816b\u760d\u5b66\u306f\u3001\u8907\u96d1\u306a\u67d3\u8272\u4f53\u7570\u5e38\u3068\u6700\u3082\u6df1\u304f\u95a2\u308f\u308b\u533b\u5b66\u306e\u4e00\u5206\u91ce\u3068\u8a00\u3048\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u304c\u3093\u3067\u306f\u3001DNA\u4fee\u5fa9\u6a5f\u69cb\u306e\u7834\u7dbb\u3084\u7a81\u7136\u5909\u7570\u306e\u84c4\u7a4d\u306b\u3088\u3063\u3066\u6b63\u78ba\u306b\u539f\u56e0\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u304c\u56f0\u96e3\u306a\u8907\u6570\u306e\u7570\u5e38\u304c\u5f15\u304d\u8d77\u3053\u3055\u308c\u3066","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-06-09T08:17:51+00:00","og_image":[{"width":350,"height":216,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"9\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e","datePublished":"2023-06-09T08:17:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/"},"wordCount":55,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg","keywords":["\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/","name":"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg","datePublished":"2023-06-09T08:17:51+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg","width":350,"height":216},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cancer-microarray-gsd-ts-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u67d3\u8272\u4f53\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4\u306b\u3088\u308b\u816b\u760d\u5b66\u75c7\u4f8b\u306e\u89e3\u660e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":71,"label":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg",350,216,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":71,"name":"\u30de\u30a4\u30af\u30ed\u30a2\u30ec\u30a4","slug":"microarray","term_group":0,"term_taxonomy_id":71,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cancer-microarray-gsd-ts-1-eyecatch.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=14429"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14429\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/14455"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=14429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=14429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=14429"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=14429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}