{"id":1445,"date":"2018-10-01T00:00:00","date_gmt":"2018-09-30T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/"},"modified":"2025-08-08T17:10:19","modified_gmt":"2025-08-08T08:10:19","slug":"cryopreservation_7","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/","title":{"rendered":"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u3053\u306e\u9023\u8f09\u3067\u306f\u3001\u51cd\u7d50\u4fdd\u5b58\u306b\u95a2\u3059\u308b\u5f79\u7acb\u3064\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u307e\u3059\u3002<br>\u666e\u6bb5\u3001\u4f55\u6c17\u306a\u304f\u611f\u3058\u3066\u3044\u308b\u3053\u3068\u306b\u5bfe\u3059\u308b\u30d2\u30f3\u30c8\u306b\u3082\u306a\u308b\u3068\u601d\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u304a\u6c17\u8efd\u306b\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306f\u3001<b>\u51cd\u7d50\u4fdd\u5b58\u306b\u304a\u3051\u308b\u51b7\u5374\u901f\u5ea6\u306e\u7a2e\u985e\u3068\u91cd\u8981\u6027\u3001\u3055\u3089\u306b\u306f\u51b7\u5374\u6642\u306e\u7d30\u80de\u640d\u50b7\u3092\u9632\u3050\u305f\u3081\u306e\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3<\/b>\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br>\u30fb\u51cd\u7d50\u4fdd\u5b58\u306e\u51b7\u5374\u901f\u5ea6\u306e\u8a73\u7d30\u3092\u77e5\u308a\u305f\u3044\u65b9<br>\u30fb\u7d30\u80de\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u304e\u3064\u3064\u3082\u624b\u8efd\u306b\u51cd\u7d50\u4fdd\u5b58\u3092\u5b9f\u65bd\u3057\u305f\u3044\u65b9<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\uff11-\u7de9\u6162\u51b7\u5374\u3068\u6025\u901f\u51b7\u5374\u306e\u9055\u3044\u3068\u306f\">\uff11\uff0e\u7de9\u6162\u51b7\u5374\u3068\u6025\u901f\u51b7\u5374\u306e\u9055\u3044\u3068\u306f\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6c34\u306f\u3059\u3079\u3066\u306e\u751f\u304d\u3066\u3044\u308b\u7d30\u80de\u306e\u4e3b\u6210\u5206\u3067\u3042\u308a\u5316\u5b66\u53cd\u5fdc\u3092\u9032\u3081\u308b\u305f\u3081\u306b\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u751f\u4f53\u5185\u306e\u3059\u3079\u3066\u306e\u6c34\u304c\u6c37\u306b\u5909\u5316\u3059\u308b\u3068\u7d30\u80de\u306e\u4ee3\u8b1d\u304c\u505c\u6b62\u3057\u307e\u3059\u3002\u51b7\u5374\u5de5\u7a0b\u306b\u304a\u3044\u3066\u3001\u6c37\u306f\u7570\u306a\u308b\u901f\u5ea6\u3067\u5f62\u6210\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7de9\u6162\u51b7\u5374\u306f\u3001\u7d30\u80de\u5185\u3067\u6c37\u304c\u5f62\u6210\u3055\u308c\u308b\u524d\u306b\u7d30\u80de\u5916\u306e\u6c34\u304c\u51cd\u7d50\u3057\u307e\u3059<sup>1<\/sup>\u3002\u7d30\u80de\u5916\u3067\u6c37\u304c\u5f62\u6210\u3055\u308c\u308b\u3068\u3001\u7d30\u80de\u5916\u74b0\u5883\u304b\u3089\u6c34\u304c\u9664\u53bb\u3055\u308c\u3001\u7d30\u80de\u819c\u306e\u5185\u5074\u3068\u5916\u5074\u306e\u9593\u306b\u6d78\u900f\u5727\u306e\u4e0d\u5747\u8861\u304c\u751f\u3058\u3001\u6c34\u304c\u7d30\u80de\u5916\u3078\u3068\u79fb\u52d5\u3057\u307e\u3059\u3002\u7d30\u80de\u5916\u306e\u6eb6\u8cea\u6fc3\u5ea6\u306e\u4e0a\u6607\u306a\u3089\u3073\u306b\u7d30\u80de\u304b\u3089\u306e\u6c34\u306e\u6d41\u51fa\u306b\u3088\u308b\u7d30\u80de\u5185\u306e\u6eb6\u8cea\u6fc3\u5ea6\u306e\u4e0a\u6607\u306f\u3001\u7d30\u80de\u306e\u751f\u5b58\u306b\u6709\u5bb3\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059<sup>1<\/sup>\u3002\u4e00\u65b9\u3067\u3001\u7d30\u80de\u5185\u306b\u904e\u5270\u306a\u6c34\u304c\u4fdd\u6301\u3055\u308c\u308b\u3068\u3001\u7d30\u80de\u5185\u6c37\u6676\u5f62\u6210\u3084\u878d\u89e3\u6642\u306e\u518d\u7d50\u6676\u5316\u306b\u3088\u308b\u640d\u50b7\u304c\u751f\u3058\u3001\u7d30\u80de\u6b7b\u3092\u62db\u304d\u307e\u3059\u3002\u51b7\u5374\u901f\u5ea6\u306f\u3053\u308c\u3089\u306e\u73fe\u8c61\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6025\u901f\u51b7\u5374\u3067\u306f\u3001\u6c37\u304c\u5747\u4e00\u306b\u5f62\u6210\u3055\u308c\u308b\u305f\u3081\u3001\u6eb6\u8cea\u6fc3\u5ea6\u306e\u4e0a\u6607\u306b\u3088\u308b\u5f71\u97ff\u306f\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3059\u304c\u3001\u7d30\u80de\u5916\u3078\u79fb\u52d5\u3059\u308b\u6c34\u306e\u91cf\u304c\u5c11\u306a\u3044\u305f\u3081\u7d30\u80de\u5185\u6c37\u6676\u5f62\u6210\u304c\u3088\u308a\u591a\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001\u7de9\u6162\u51b7\u5374\u3067\u306f\u7d30\u80de\u5916\u3078\u79fb\u52d5\u3059\u308b\u6c34\u306e\u91cf\u304c\u591a\u3044\u305f\u3081\u3001\u7d30\u80de\u5185\u6c37\u6676\u5f62\u6210\u306f\u6291\u3048\u3089\u308c\u307e\u3059\u304c\u3001\u6eb6\u8cea\u6fc3\u5ea6\u304c\u4e0a\u6607\u3057\u307e\u3059\u3002\u7d30\u80de\u819c\u306e\u900f\u904e\u6027\u306f\u6c34\u306e\u6d41\u51fa\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u3001\u7d30\u80de\u819c\u306e\u900f\u904e\u6027\u304c\u9ad8\u3044\u7d30\u80de\u306e\u307b\u3046\u304c\u900f\u904e\u6027\u306e\u4f4e\u3044\u7d30\u80de\u3088\u308a\u3082\u6025\u901f\u51b7\u5374\u306b\u826f\u597d\u306a\u8010\u6027\u3092\u793a\u3057\u307e\u3059<sup>2<\/sup>\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Mazur\u3089\u306f\u3001<b>\u7d30\u80de\u640d\u50b7\u306b\u306f\u6c37\u6676\u5f62\u6210\u304a\u3088\u3073\u6eb6\u8cea\u52b9\u679c\u306e\u4e21\u65b9\u304c\u95a2\u4e0e\u3057\u3066\u304a\u308a\u3001\u6700\u9069\u306a\u51b7\u5374\u901f\u5ea6\u306b\u3088\u308a\u305d\u308c\u305e\u308c\u306e\u5f71\u97ff\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3042\u308b\u3068\u793a\u3057\u3066\u3044\u307e\u3059<sup>3<\/sup><\/b>\u3002\u4e00\u90e8\u306e\u4f8b\u5916\u3092\u9664\u304d\u3001\u6bce\u52061\u00b0C\u306e\u51b7\u5374\u901f\u5ea6\u304c\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\uff12-\u51b7\u5374\u901f\u5ea6\u306e\u91cd\u8981\u6027\">\uff12\uff0e\u51b7\u5374\u901f\u5ea6\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7d30\u80de\u3068\u51cd\u7d50\u4fdd\u8b77\u5264\uff08DMSO\u3084\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u306a\u3069\uff09\u3092\u6df7\u5408\u3057\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u8abf\u88fd\u3057\u305f\u3042\u3068\u3001\u61f8\u6fc1\u6db2\u3092\u51b7\u5374\u3057\u307e\u3059\uff08\u7d30\u80de\u306e\u51cd\u7d50\u65b9\u6cd5\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/freezing-and-thawing-cells\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\uff09\u3002\u7d30\u80de\u306e\u51b7\u5374\u901f\u5ea6\u306f\u6c37\u6676\u306e\u5f62\u6210\u91cf\u3084\u30b5\u30a4\u30ba\u3001\u307e\u305f\u51cd\u7d50\u4e2d\u306b\u767a\u751f\u3059\u308b\u6eb6\u6db2\u52b9\u679c\uff08\u6eb6\u8cea\u6fc3\u5ea6\u306e\u4e0a\u6607\uff09\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u305f\u3081\u3001\u3068\u3066\u3082\u91cd\u8981\u3067\u3059\u3002\u7d30\u80de\u306e\u7a2e\u985e\u306b\u3088\u308a\u9069\u5207\u306a\u51b7\u5374\u901f\u5ea6\u306f\u7570\u306a\u308a\u307e\u3059\u304c\u3001\u5e45\u5e83\u3044\u7a2e\u985e\u306e\u7d30\u80de\u3084\u751f\u7269\u306b\u304a\u3044\u3066\u30011\u00b0C\uff0f\u5206\u306e\u5747\u4e00\u306a\u51b7\u5374\u901f\u5ea6\u304c\u52b9\u679c\u7684\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306b\u3001\u5927\u304d\u306a\u7d30\u80de\u307b\u3069\u3086\u3063\u304f\u308a\u3068\u51b7\u5374\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u591a\u304f\u306e\u7d30\u83cc\u3084\u80de\u5b50\u3092\u5f62\u6210\u3059\u308b\u771f\u83cc\u306f\u3001\u7406\u60f3\u7684\u3068\u306f\u3044\u3048\u306a\u3044\u51b7\u5374\u6761\u4ef6\u306b\u3082\u8010\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u8a66\u6599\u3092-80\u00b0C\u306b\u3057\u3070\u3089\u304f\u653e\u7f6e\u3059\u308b\u3053\u3068\u3067\u51cd\u7d50\u3067\u304d\u307e\u3059\u3002\u4e00\u65b9\u3001\u3088\u308a\u611f\u53d7\u6027\u306e\u9ad8\u3044\u7d30\u83cc\u3084\u80de\u5b50\u3092\u5f62\u6210\u3057\u306a\u3044\u771f\u83cc\u306f\u3001\u3088\u308a\u5747\u4e00\u306a\u51b7\u5374\u901f\u5ea6\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002\u539f\u751f\u751f\u7269\u3084\u54fa\u4e73\u985e\u7d30\u80de\u3001\u690d\u7269\u7d30\u80de\u306f\u3001\u904e\u51b7\u5374\u3082\u3057\u304f\u306f\u6c34\u304b\u3089\u6c37\u3078\u306e\u76f8\u5909\u5316\u4e2d\u306b\u767a\u751f\u3059\u308b\u6f5c\u71b1\u306e\u6709\u5bb3\u306a\u5f71\u97ff\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306e\u7279\u5225\u306a\u64cd\u4f5c\u3092\u5fc5\u8981\u3068\u3057\u3001\u3055\u3089\u306b\u53b3\u683c\u306a\u51b7\u5374\u901f\u5ea6\u306e\u5236\u5fa1\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7d30\u80de\u5185\u5916\u306b\u5b58\u5728\u3059\u308b\u6c34\u306f\u7d04-2\u00b0C\uff5e-5\u00b0C\u3067\u51cd\u7d50\u3057\u307e\u3059\u3002\u6db2\u4f53\u304b\u3089\u7d50\u6676\u3078\u306e\u76f8\u5909\u5316\u3067\u306f\u3001\u878d\u89e3\u6f5c\u71b1\u3068\u547c\u3070\u308c\u308b\u71b1\u306e\u5f62\u3067\u30a8\u30cd\u30eb\u30ae\u30fc\u304c\u653e\u51fa\u3055\u308c\u307e\u3059\u3002\u904e\u51b7\u5374\u72b6\u614b\u304b\u3089\u5e73\u8861\u51dd\u56fa\u70b9\u306b\u5230\u9054\u3059\u308b\u307e\u3067\u51dd\u56fa\u71b1\u304c\u653e\u51fa\u3055\u308c\u3066\u6e29\u5ea6\u304c\u3042\u304c\u308a\u3001\u51dd\u56fa\u70b9\u306b\u5230\u9054\u3059\u308b\u3068\u51dd\u56fa\u304c\u306f\u3058\u307e\u308a\u3001\u6c37\u304c\u5f62\u6210\u3055\u308c\u3066\u3044\u304d\u307e\u3059\u3002\u3053\u306e\u73fe\u8c61\u304c\u53ca\u307c\u3059\u6709\u5bb3\u306a\u5f71\u97ff\u3092\u4f4e\u6e1b\u3059\u308b\u305f\u3081\u3001\u4eba\u70ba\u7684\u306b\u6c37\u6676\u5f62\u6210\u3092\u8a98\u5c0e\u3057\u3001\u904e\u51b7\u5374\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u6c37\u6676\u5f62\u6210\u3092\u4fc3\u9032\u3055\u305b\u308b\u305f\u3081\u306b\u306f\u3001\u904e\u51b7\u5374\u72b6\u614b\u306e\u6eb6\u6db2\u306b\u6c37\u3082\u3057\u304f\u306f\u4f55\u3089\u304b\u306e\u6838\u5316\u5264\u306e\u30b7\u30fc\u30c7\u30a3\u30f3\u30b0\u3059\u308b\u3053\u3068\u3001\u307e\u305f\u306f\u904e\u51b7\u5374\u72b6\u614b\u307e\u3067\u51b7\u5374\u3057\u305f\u3042\u3068\u306b\u6025\u51b7\u3059\u308b\u3053\u3068\u304c\u52b9\u679c\u7684\u3068\u8a00\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\uff13-\u30d7\u30ed\u30b0\u30e9\u30e0\u30d5\u30ea\u30fc\u30b6\u30fc\">\uff13\uff0e\u30d7\u30ed\u30b0\u30e9\u30e0\u30d5\u30ea\u30fc\u30b6\u30fc<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u51b7\u5374\u901f\u5ea6\u3092\u5236\u5fa1\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u51b7\u5374\u901f\u5ea6\u3092\u30d7\u30ed\u30b0\u30e9\u30e0\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u7d30\u80de\u51cd\u7d50\u88c5\u7f6e\u3001\u3044\u308f\u3086\u308b\u30d7\u30ed\u30b0\u30e9\u30e0\u30d5\u30ea\u30fc\u30b6\u30fc\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<b>\u30b7\u30f3\u30d7\u30eb\u306a\u88c5\u7f6e\u3067\u306f\u3001\u3059\u3079\u3066\u306e\u6e29\u5ea6\u7bc4\u56f2\u306b\u5bfe\u3057\u3066\u5358\u4e00\u306e\u51b7\u5374\u901f\u5ea6\u3057\u304b\u9078\u629e\u3059\u308b\u3053\u3068\u304b\u3067\u304d\u307e\u305b\u3093\u3002<\/b><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3057\u304b\u3057\u3001\u3088\u308a\u9ad8\u5ea6\u306a\u88c5\u7f6e\u3067\u306f\u51b7\u5374\u66f2\u7dda\u306e\u6e29\u5ea6\u306b\u5fdc\u3058\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u901f\u5ea6\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\uff14-\u7c21\u6613-\u7d30\u80de\u51cd\u7d50\u30b7\u30b9\u30c6\u30e0\">\uff14\uff0e\u7c21\u6613\u30fb\u7d30\u80de\u51cd\u7d50\u30b7\u30b9\u30c6\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3088\u308a\u5b89\u4fa1\u3067\u4f7f\u3044\u52dd\u624b\u306e\u826f\u3044\u7d30\u80de\u51cd\u7d50\u30b7\u30b9\u30c6\u30e0\u3068\u3057\u3066\u3001-60\u00b0C\uff5e-80\u00b0C\u306e\u8d85\u4f4e\u6e29\u30d5\u30ea\u30fc\u30b6\u30fc\u5185\u306b\u30d0\u30a4\u30a2\u30eb\u3092\u9759\u7f6e\u3059\u308b\u3053\u3068\u3067\u51b7\u5374\u901f\u5ea6\u3092\u5236\u5fa1\u3057\u305f\u51b7\u5374\u30d7\u30ed\u30bb\u30b9\u3092\u6a21\u5023\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u5747\u4e00\u306a\u51b7\u5374\u901f\u5ea6\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u30d0\u30a4\u30a2\u30eb\u3092\u300e\u7279\u5225\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u305f\u5bb9\u5668\u300f\u306b\u9759\u7f6e\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002\u767a\u6ce1\u30b9\u30c1\u30ed\u30fc\u30eb\u306a\u3069\u3067\u4f5c\u3089\u308c\u305f\u81ea\u5bb6\u88fd\u306e\u7d30\u80de\u51cd\u7d50\u30b7\u30b9\u30c6\u30e0\u306e\u4e00\u822c\u7684\u306a\u51b7\u5374\u901f\u5ea6\u306f\u5e73\u5747\u30671\u00b0C\uff0f\u5206\u3068\u8a00\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001<b>\u51b7\u5374\u66f2\u7dda\u306e\u3042\u308b\u90e8\u5206\u3067\u306f\u3088\u308a\u901f\u3044\u51b7\u5374\u901f\u5ea6\u3067\u7d30\u80de\u306f\u51cd\u7d50\u3055\u308c\u3066\u304a\u308a\u3001\u5747\u4e00\u306a\u51b7\u5374\u901f\u5ea6\u3092\u5f97\u308b\u3053\u3068\u306f\u96e3\u3057\u304f\u306a\u308a\u307e\u3059<sup>3<\/sup>\u3002\u307e\u305f\u3001\u3053\u306e\u3088\u3046\u306a\u81ea\u5bb6\u88fd\u306e\u7d30\u80de\u51cd\u7d50\u30b7\u30b9\u30c6\u30e0\u306b\u306f\u51b7\u5374\u901f\u5ea6\u306e\u518d\u73fe\u6027\u3082\u671f\u5f85\u3067\u304d\u307e\u305b\u3093\u3002<\/b><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\uff15-\u5747\u4e00\u306a\u51b7\u5374\u901f\u5ea6\u3067\u624b\u8efd\u306b\u7d30\u80de\u3092\u51cd\u7d50\u3059\u308b\u65b9\u6cd5\">\uff15\uff0e\u5747\u4e00\u306a\u51b7\u5374\u901f\u5ea6\u3067\u624b\u8efd\u306b\u7d30\u80de\u3092\u51cd\u7d50\u3059\u308b\u65b9\u6cd5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sample-storage-management\/sample-storage-tubes\/accessories.html?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 Nalgene\u2122 Mr. Frosty \u51cd\u7d50\u51e6\u7406\u5bb9\u5668\uff08\u88fd\u54c1\u756a\u53f7:5100-0001\uff09<\/a>\u306f\u3001\u7c21\u6613\u306a\u7d30\u80de\u51cd\u7d50\u30b7\u30b9\u30c6\u30e0\u3067\u3042\u308a\u30011\u00b0C\uff0f\u5206\u306b\u8fd1\u3044\u51b7\u5374\u901f\u5ea6\u3092\u9054\u6210\u3067\u304d\u308b\u3088\u3046\u306b\u30c7\u30b6\u30a4\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\uff08\u56f36\uff09\u3002\u4f7f\u3044\u65b9\u3082\u7c21\u5358\u3067\u3042\u308a\u3001\u53d7\u3051\u5bb9\u5668\u306e\u6c34\u4f4d\u30e9\u30a4\u30f3\u307e\u3067100%\u30a4\u30bd\u30d7\u30ed\u30d4\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u3092\u6ce8\u304e\u3001\u4ed8\u5c5e\u306e\u53d7\u3051\u76bf\u3092\u4e57\u305b\u3001\u53d7\u3051\u76bf\u306e\u30d0\u30a4\u30a2\u30eb\u633f\u5165\u90e8\u4f4d\u306b\u30d0\u30a4\u30a2\u30eb\u3092\u9759\u7f6e\u3057\u3001\u30d5\u30bf\u3092\u5360\u3081\u3066-80\u2103\u306e\u8d85\u4f4e\u6e29\u30d5\u30ea\u30fc\u30b6\u30fc\u306b4\u6642\u9593\u4ee5\u4e0a\u9759\u7f6e\u3059\u308b\u3060\u3051\u3067\u6bce\u52061\u5206\u7a0b\u5ea6\u306e\u51b7\u5374\u901f\u5ea6\u3067\u7d30\u80de\u306e\u7de9\u6162\u51cd\u7d50\u304c\u3067\u304d\u307e\u3059\u3002\u7de9\u6162\u51cd\u7d50\u5f8c\u306f\u3001\u30d0\u30a4\u30a2\u30eb\u3092\u6db2\u4f53\u7a92\u7d20\uff08-130\u2103\u3082\u3057\u304f\u306f\u305d\u308c\u4ee5\u4e0b\uff09\u306b\u6d78\u3057\u3066\u6025\u51b7\u3057\u307e\u3059\u3002\u7de9\u6162\u51cd\u7d50\u306b\u3088\u308a\u7d30\u80de\u5185\u304c\u8131\u6c34\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u6025\u51b7\u3057\u3066\u3082\u7d30\u80de\u5185\u3067\u306e\u6c37\u6676\u5f62\u6210\u306f\u6291\u5236\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001<b>\u7d30\u80de\u5185\u5916\u306b\u304a\u3051\u308b\u6c37\u6676\u5f62\u6210\u306b\u3088\u308b\u7d30\u80de\u640d\u50b7\u3092\u6291\u3048\u306a\u304c\u3089\u3001\u51cd\u7d50\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/b><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u518d\u73fe\u6027\u306e\u3042\u308b\u5b9f\u9a13\u7d50\u679c\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u7d30\u80de\u3092\u306f\u3058\u3081\u3068\u3057\u305f\u7814\u7a76\u8a66\u6599\u306e\u4fdd\u5b58\u306b\u306f\u7d30\u5fc3\u306e\u6ce8\u610f\u3092\u6255\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u65e5\u3005\u306e\u7d30\u80de\u57f9\u990a\u306e\u4e2d\u3067\u898b\u843d\u3068\u3055\u308c\u304c\u3061\u306a\u51cd\u7d50\u4fdd\u5b58\u65b9\u6cd5\u3002\u305c\u3072\u4e00\u5ea6\u30e9\u30dc\u3067\u306e\u51cd\u7d50\u4fdd\u5b58\u65b9\u6cd5\u3092\u518d\u78ba\u8a8d\u3057\u3066\u307f\u3066\u306f\u3044\u304b\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u51cd\u7d50\u4fdd\u5b58\u306e\u6e29\u5ea6\u306b\u3064\u3044\u3066\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_4\/?cid=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a><br>\u51cd\u7d50\u4fdd\u5b58\u306b\u9069\u3057\u305f\u6e29\u5ea6\u306f\u4f55\u5ea6\u306a\u306e\u304b\uff1f\u6db2\u4f53\u7a92\u7d20\u5bb9\u5668\u306e\u30a4\u30e9\u30b9\u30c8\u3068\u5171\u306b\u8a73\u7d30\u60c5\u5831\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-\u5f53\u793e\u306e\u51cd\u7d50\u4fdd\u5b58\u30c1\u30e5\u30fc\u30d6\u3092-\u307e\u305a\u306f\u30b5\u30f3\u30d7\u30eb\u3067\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\">\u5f53\u793e\u306e\u51cd\u7d50\u4fdd\u5b58\u30c1\u30e5\u30fc\u30d6\u3092\u3001\u307e\u305a\u306f\u30b5\u30f3\u30d7\u30eb\u3067\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002<\/h4>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/life-science\/cryopreservation-tube-sample.html?cid=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">\u30b5\u30f3\u30d7\u30eb\u3092\u7533\u3057\u8fbc\u3080<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-\u30c1\u30e5\u30fc\u30d6-\u30d7\u30ec\u30fc\u30c8-\u51cd\u7d50\u4fdd\u5b58\u7528\u88fd\u54c1\u30ab\u30bf\u30ed\u30b0\">\u30c1\u30e5\u30fc\u30d6\uff06\u30d7\u30ec\u30fc\u30c8 &#8211; \u51cd\u7d50\u4fdd\u5b58\u7528\u88fd\u54c1\u30ab\u30bf\u30ed\u30b0<\/h4>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/LPD\/Scientific-Resources\/sample-storage-products-catalog-ja.pdf?cid=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-gibco\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\">Gibco\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h4>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?cid=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\uff1c\u8cc7\u6599\u8acb\u6c42\u30fb\u304a\u554f\u3044\u5408\u308f\u305b\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/demo-2d-tube.html?cid=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\" data-wplink-edit=\"true\">\u3053\u3061\u3089<\/a>\u304b\u3089\uff1e<\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u95a2\u9023\u60c5\u5831\">\u95a2\u9023\u60c5\u5831<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u53c2\u8003\u6587\u732e<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><span style=\"font-size: 8pt\">Simione, F.P. 1992. Key issues relating to the genetic stability and preservation of cells and cell banks. J. Parent. Science and Technology 46: 226-232.<\/span><\/li>\n\n\n\n<li><span style=\"font-size: 8pt\">Nei, T., T. Araki and T. Matsusaka.1969. Freezing injury to aerated and non-aerated cultures of Escherichia coli. In T. Nei, Ed. Freezing and Drying of Microorganisms. University of Tokyo Press, Tokyo, Japan.<\/span><\/li>\n\n\n\n<li><span style=\"font-size: 8pt\">Simione, F.P., P.M. Daggett, M.S. MacGrath and M.T. Alexander. 1977. The use of plastic ampoules for freeze preservation of microorganisms. Cryobiology 14: 500-502.<\/span><\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba-\u305d\u306e\u4ed6\u306e\u8a18\u4e8b\u306f\u3053\u3061\u3089\">\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3001\u305d\u306e\u4ed6\u306e\u8a18\u4e8b\u306f\u3053\u3061\u3089<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_1\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 1\u3011\u30af\u30e9\u30a4\u30aa\u30c1\u30e5\u30fc\u30d6\u9078\u3073\u3067\u5927\u5207\u306a\uff15\u3064\u306e\u3053\u3068<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_2\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 2\u3011\u30b5\u30f3\u30d7\u30eb\u3092\u6db2\u4f53\u7a92\u7d20\u6e29\u5ea6\u4e0b\u3067\u5b89\u5168\u306b\u4fdd\u5b58\u3059\u308b\u79d8\u8a23<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_3\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 3\u3011\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\uff01\u51cd\u7d50\u4fdd\u8b77\u5264\u306e\u8c46\u77e5\u8b58<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_4\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 4\u3011\u51cd\u7d50\u4fdd\u5b58\u306e\u6e29\u5ea6\u306b\u3064\u3044\u3066<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_5\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 5\u3011\u3053\u308c\u3067\u30ab\u30f3\u30da\u30ad\uff01\u751f\u7269\u8a66\u6599\u306e\u56de\u53ce\u3068\u8abf\u6574\u6cd5<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_6\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 6\u3011\u30b7\u30fc\u30c9\u30ed\u30c3\u30c8\u30b7\u30b9\u30c6\u30e0\u3063\u3066\u77e5\u3063\u3066\u3044\u307e\u3059\u304b\uff1f<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_8-2\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 8\u3011\u51cd\u7d50\u4fdd\u5b58\u306b\u9069\u3057\u305f\u4fdd\u5b58\u5bb9\u5668\u3068\u306f\uff1f<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/freeze-preservation-laboratory-9-lpd-24070\/?CID=lpd_lpe_cls_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_tube3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 9\u3011\u30ac\u30b9\u30b1\u30c3\u30c8\u306e\u91cd\u8981\u6027<\/a><\/li>\n<\/ul>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3053\u306e\u9023\u8f09\u3067\u306f\u3001\u51cd\u7d50\u4fdd\u5b58\u306b\u95a2\u3059\u308b\u5f79\u7acb\u3064\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u307e\u3059\u3002\u666e\u6bb5\u3001\u4f55\u6c17\u306a\u304f\u611f\u3058\u3066\u3044\u308b\u3053\u3068\u306b\u5bfe\u3059\u308b\u30d2\u30f3\u30c8\u306b\u3082\u306a\u308b\u3068\u601d\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u304a\u6c17\u8efd\u306b\u3054\u89a7\u304f\u3060\u3055\u3044\u3002 \u4eca\u56de\u306f\u3001\u51cd\u7d50\u4fdd\u5b58\u306b\u304a\u3051\u308b\u51b7\u5374\u901f\u5ea6\u306e\u7a2e\u985e\u3068\u91cd\u8981\u6027\u3001\u3055\u3089\u306b\u306f\u51b7\u5374\u6642\u306e\u7d30\u80de\u640d<\/p>\n","protected":false},"author":975,"featured_media":4909,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[125],"division":[],"class_list":["post-1445","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cell","tag-freeze-preservation","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064\" \/>\n<meta property=\"og:description\" content=\"\u3053\u306e\u9023\u8f09\u3067\u306f\u3001\u51cd\u7d50\u4fdd\u5b58\u306b\u95a2\u3059\u308b\u5f79\u7acb\u3064\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u307e\u3059\u3002\u666e\u6bb5\u3001\u4f55\u6c17\u306a\u304f\u611f\u3058\u3066\u3044\u308b\u3053\u3068\u306b\u5bfe\u3059\u308b\u30d2\u30f3\u30c8\u306b\u3082\u306a\u308b\u3068\u601d\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u304a\u6c17\u8efd\u306b\u3054\u89a7\u304f\u3060\u3055\u3044\u3002 \u4eca\u56de\u306f\u3001\u51cd\u7d50\u4fdd\u5b58\u306b\u304a\u3051\u308b\u51b7\u5374\u901f\u5ea6\u306e\u7a2e\u985e\u3068\u91cd\u8981\u6027\u3001\u3055\u3089\u306b\u306f\u51b7\u5374\u6642\u306e\u7d30\u80de\u640d\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-09-30T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-08T08:10:19+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6-1024x682.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"682\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064\",\"datePublished\":\"2018-09-30T15:00:00+00:00\",\"dateModified\":\"2025-08-08T08:10:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/\"},\"wordCount\":109,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg\",\"keywords\":[\"\u51cd\u7d50\u4fdd\u5b58\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/\",\"name\":\"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg\",\"datePublished\":\"2018-09-30T15:00:00+00:00\",\"dateModified\":\"2025-08-08T08:10:19+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg\",\"width\":4928,\"height\":3280,\"caption\":\"\u51cd\u7d50\u4fdd\u5b58\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cryopreservation_7\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064","og_description":"\u3053\u306e\u9023\u8f09\u3067\u306f\u3001\u51cd\u7d50\u4fdd\u5b58\u306b\u95a2\u3059\u308b\u5f79\u7acb\u3064\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u307e\u3059\u3002\u666e\u6bb5\u3001\u4f55\u6c17\u306a\u304f\u611f\u3058\u3066\u3044\u308b\u3053\u3068\u306b\u5bfe\u3059\u308b\u30d2\u30f3\u30c8\u306b\u3082\u306a\u308b\u3068\u601d\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u304a\u6c17\u8efd\u306b\u3054\u89a7\u304f\u3060\u3055\u3044\u3002 \u4eca\u56de\u306f\u3001\u51cd\u7d50\u4fdd\u5b58\u306b\u304a\u3051\u308b\u51b7\u5374\u901f\u5ea6\u306e\u7a2e\u985e\u3068\u91cd\u8981\u6027\u3001\u3055\u3089\u306b\u306f\u51b7\u5374\u6642\u306e\u7d30\u80de\u640d","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-09-30T15:00:00+00:00","article_modified_time":"2025-08-08T08:10:19+00:00","og_image":[{"width":1024,"height":682,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6-1024x682.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"10\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064","datePublished":"2018-09-30T15:00:00+00:00","dateModified":"2025-08-08T08:10:19+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/"},"wordCount":109,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg","keywords":["\u51cd\u7d50\u4fdd\u5b58"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/","name":"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg","datePublished":"2018-09-30T15:00:00+00:00","dateModified":"2025-08-08T08:10:19+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg","width":4928,"height":3280,"caption":"\u51cd\u7d50\u4fdd\u5b58"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cryopreservation_7\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u51cd\u7d50\u4fdd\u5b58\u306e\u57fa\u790e 7\u3011\u7d30\u80de\u306e\u51cd\u7d50\u51b7\u5374\u901f\u5ea6\u306e\u3072\u307f\u3064"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":125,"label":"\u51cd\u7d50\u4fdd\u5b58"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6-1024x682.jpg",760,506,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":104,"filter":"raw","meta":[],"cat_ID":159,"category_count":104,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":125,"name":"\u51cd\u7d50\u4fdd\u5b58","slug":"freeze-preservation","term_group":0,"term_taxonomy_id":125,"taxonomy":"post_tag","description":"","parent":0,"count":15,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":1445,"position":0},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":1445,"position":1},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24416,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076\/","url_meta":{"origin":1445,"position":2},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066\uff08MitoTracker\u3092\u7528\u3044\u305f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670819\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24587,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-26003\/","url_meta":{"origin":1445,"position":3},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2468 \u5f8c\u5de5\u7a0b\u3068\u30b5\u30f3\u30d7\u30eb\u306e\u56de\u53ce \u30da\u30ec\u30bf\u30a4\u30ba","author":"LatB Staff","date":"2026\u5e741\u670822\u65e5","format":false,"excerpt":"\u66f4\u65b0\u65e5 : \u3053\u306e\u8a18\u4e8b\u306e\u8981\u70b9 \u30da\u30ec\u30bf\u30a4\u30ba\u306f\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u5f8c\u306e\u4ee3\u8868\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\u6cd5\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/twin-screw-extrusion-extruder-cad-26003_eyeycatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24729,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-26010\/","url_meta":{"origin":1445,"position":4},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2469 \u5f8c\u5de5\u7a0b\u3068\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\uff1a\u30d5\u30ec\u30fc\u30af","author":"LatB Staff","date":"2026\u5e743\u67083\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3068\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/Figure-05-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/Figure-05-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/Figure-05-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/Figure-05-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/Figure-05-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/Figure-05-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":1445,"position":5},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/b043e4605eb277ce1a98d06bc0d934f7-6.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1445","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1445"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1445\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/4909"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1445"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1445"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1445"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1445"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}