{"id":14556,"date":"2023-06-27T15:13:11","date_gmt":"2023-06-27T06:13:11","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=14556"},"modified":"2024-09-18T16:09:39","modified_gmt":"2024-09-18T07:09:39","slug":"data_app_ce_gsd_ts_2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/","title":{"rendered":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01"},"content":{"rendered":"<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u30e9\u30f3\u304c\u7d42\u308f\u308a\u3001\u3044\u3056\u30b7\u30fc\u30b1\u30f3\u30b9\u30c7\u30fc\u30bf\uff08.ab1\uff09\u3092\u958b\u3044\u3066\u307f\u308b\u3068\u3001\u6ce2\u5f62\u306f\u78ba\u8a8d\u3067\u304d\u308b\u3082\u306e\u306e\u3001\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5869\u57fa\u914d\u5217\u304c\u201dNNNNN\u201d\u3060\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f<\/p>\n<div id=\"attachment_14569\" style=\"width: 630px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14569\" class=\"size-full wp-image-14569\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-01.png\" alt=\"\u201dNNNNN\u201d\" width=\"620\" height=\"322\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-01.png 620w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-01-300x156.png 300w\" sizes=\"auto, (max-width: 620px) 100vw, 620px\" \/><p id=\"caption-attachment-14569\" class=\"wp-caption-text\">\u56f31: \u201dNNNNN\u201d<\/p><\/div>\n<p>\u3053\u308c\u306f\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u3066\u518d\u5ea6\u89e3\u6790\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3057\u76f4\u3059\u3053\u3068\u304c\u3067\u304d\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u201dNNNNN\u201d\u3068\u306a\u3063\u3066\u3044\u308b\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\u3092\u518d\u89e3\u6790\u3059\u308b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3001\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/p>\n<ul>\n<li>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3092\u5b9f\u65bd\u3057\u3066\u3044\u308b\u65b9<\/li>\n<li>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u30c7\u30fc\u30bf\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\u306b\u8208\u5473\u3092\u304a\u6301\u3061\u306e\u65b9<\/li>\n<\/ul>\n<h2>\u201dNNNNN\u201d\u3068\u306a\u3063\u3066\u3057\u307e\u3046\u539f\u56e0\u306f\uff1f<\/h2>\n<p>\u6b63\u3057\u304f\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3067\u304d\u3066\u3044\u306a\u3044\u5834\u5408\u3001\u751f\u30c7\u30fc\u30bf\u300cRaw\u300d\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n<ul>\n<li>Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u5834\u5408\u3001\u300cRaw\u300d\u30bf\u30d6\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002\n<ol>\n<li>Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u958b\u304f<\/li>\n<li>\u300cFile\u300d \uff1e \u300cAdd Sample\uff08s\uff09&#8230;\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u4efb\u610f\u306e.ab1\u30d5\u30a1\u30a4\u30eb\u3092\u9078\u629e\u3057\u3001\u300cAdd Selected Samples &gt;&gt;\u300d\u3000\uff1e \u300cOK\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u8a72\u5f53\u306e\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\u306e\u300cShow\u300d\u306b\u30c1\u30a7\u30c3\u30af\u3092\u3064\u3051\u308b<\/li>\n<li>\u300cRaw\u300d\u30bf\u30d6\u3092\u30af\u30ea\u30c3\u30af\n<p><div id=\"attachment_14570\" style=\"width: 1514px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14570\" class=\"size-full wp-image-14570\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-02.png\" alt=\"Sequencing Analysis\u306e\u5834\u5408\u306eRaw\" width=\"1504\" height=\"253\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-02.png 1504w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-02-300x50.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-02-1024x172.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-02-768x129.png 768w\" sizes=\"auto, (max-width: 1504px) 100vw, 1504px\" \/><p id=\"caption-attachment-14570\" class=\"wp-caption-text\">\u56f32\uff1aSequencing Analysis\u306e\u5834\u5408\u306eRaw<\/p><\/div><\/li>\n<\/ol>\n<\/li>\n<li>Thermo Fisher\u2122 Connect\u2122 Platform\u306eQuality Check\u306e\u5834\u5408\u30011\u3064\u306e\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\u3092\u30c0\u30d6\u30eb\u30af\u30ea\u30c3\u30af\u3057\u3001\u300cRaw\u300d\u30bf\u30d6\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002\n<ol>\n<li>Thermo Fisher Connect Platform\u306b\u30b5\u30a4\u30f3\u30a4\u30f3\uff08<a href=\"https:\/\/apps.thermofisher.com\/?CID=gsd_cap_lcs_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_data_app_ce_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/apps.thermofisher.com\/<\/a>\uff09<\/li>\n<li>\u300cQuality Check\u300d App\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u300cCreate New Project\u300d\u3092\u9078\u629e\u5f8c\u3001\u300cType a project name\u300d\u306b\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u540d\u3092\u5165\u529b\u3057\u3001\u300cOK\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u300cImport From\u300d \uff1e \u300cMy Computer\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u4efb\u610f\u306e.ab1\u30d5\u30a1\u30a4\u30eb\u3092\u9078\u629e\u3057\u3001\u300cOpen\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u5de6\u67a0\u306e\u300cQC\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u300cImport Project Settings\u300d\u3067\u300cNo\u300d\u3092\u9078\u629e\u3057\u3001\u300cContinue\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u8a72\u5f53\u306e1\u30b5\u30f3\u30d7\u30eb\u3092\u30c0\u30d6\u30eb\u30af\u30ea\u30c3\u30af<\/li>\n<li>\u300cRaw\u300d\u30bf\u30d6\u3092\u30af\u30ea\u30c3\u30af\n<p><div id=\"attachment_14563\" style=\"width: 1350px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14563\" class=\"wp-image-14563 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-03.png\" alt=\"Quality Check\u306e\u5834\u5408\u306eRaw\" width=\"1340\" height=\"557\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-03.png 1340w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-03-300x125.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-03-1024x426.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-03-768x319.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><p id=\"caption-attachment-14563\" class=\"wp-caption-text\">\u56f33\uff1aQuality Check\u306e\u5834\u5408\u306eRaw<\/p><\/div><\/li>\n<\/ol>\n<\/li>\n<\/ul>\n<p>\u30bf\u30fc\u30b2\u30c3\u30c8\u914d\u5217\u304c\u77ed\u3044\u3082\u306e\u306e\u3001\u9577\u3044\u30bf\u30fc\u30b2\u30c3\u30c8\u7528\u306e\u30e9\u30f3\u30e2\u30b8\u30e5\u30fc\u30eb\u3067\u30e9\u30f3\u3057\u3066\u3044\u308b\u305f\u3081\u306b\u3001\u6b63\u3057\u304f\u89e3\u6790\u3067\u304d\u305a\u306b\u3001\u89e3\u6790\u4e0d\u80fd\u201dNNNNN\u201d\u3068\u306a\u3063\u3066\u3044\u308b\u5834\u5408\u304c\u591a\u3044\u3067\u3059\u3002<br \/>\n\u3053\u306e\u5834\u5408\u3001\u77ed\u3044\u30bf\u30fc\u30b2\u30c3\u30c8\u7528\u306e\u30e9\u30f3\u30e2\u30b8\u30e5\u30fc\u30eb\u3067\u30e9\u30f3\u3092\u3059\u308c\u3070\u89e3\u6d88\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\u305d\u308c\u3067\u3082\u89e3\u6d88\u3057\u306a\u3044\u5834\u5408\u3084\u65e2\u306b\u53d6\u5f97\u3057\u305f\u30c7\u30fc\u30bf\u30d5\u30a1\u30a4\u30eb\u306b\u3064\u3044\u3066\u306f\u3001\u4ee5\u4e0b\u306e\u624b\u9806\u3067\u518d\u89e3\u6790\u3092\u8a66\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n<h2>Sequencing Analysis \u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306e\u518d\u89e3\u6790<\/h2>\n<ul>\n<li>\u624b\u98061\uff1a Raw\u30c7\u30fc\u30bf\u306b\u3066\u3001\u6700\u5f8c\u306e\u30d4\u30fc\u30af\u306e\u4f4d\u7f6e\u3092\u78ba\u8a8d\n<ul>\n<li>Raw\u30c7\u30fc\u30bf\u306e\u6ce2\u5f62\u306e\u4e0a\u306b\u30ab\u30fc\u30bd\u30eb\u3092\u79fb\u52d5\u3057\u3001\u30c9\u30e9\u30c3\u30b0\u3059\u308b\u3068\u3001\u5341\u5b57\u306e\u70b9\u7dda\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/li>\n<li>\u30c9\u30e9\u30c3\u30b0\u3057\u305f\u307e\u307e\u3001\u6700\u5f8c\u306e\u30d4\u30fc\u30af\u306b\u79fb\u52d5\u3057\u3001\u6a2a\u8ef8\uff08\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\uff09\u306e\u6570\u5b57\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/li>\n<li>\u56f34\u3067\u306f\u6700\u5f8c\u306e\u30d4\u30fc\u30af\u306e\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\u306f\u300c2548\u300d\u3067\u3059\u3002\n<p><div id=\"attachment_14564\" style=\"width: 786px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14564\" class=\"size-full wp-image-14564\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-04.png\" alt=\"SeqA\u3067\u306e\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\u306e\u78ba\u8a8d\" width=\"776\" height=\"312\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-04.png 776w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-04-300x121.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-04-768x309.png 768w\" sizes=\"auto, (max-width: 776px) 100vw, 776px\" \/><p id=\"caption-attachment-14564\" class=\"wp-caption-text\">\u56f34\uff1aSeqA\u3067\u306e\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\u306e\u78ba\u8a8d<\/p><\/div><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\u624b\u98062\uff1a\u300cStop\u300d\u306b\u78ba\u8a8d\u3057\u305f\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\u3092\u5165\u529b\n<ul>\n<li>\u8a72\u5f53\u30b5\u30f3\u30d7\u30eb\u306e\u300cStop\u300d\u306b\u624b\u98061\u3067\u78ba\u8a8d\u3057\u305f\u6700\u5f8c\u306e\u30d4\u30fc\u30af\u306e\u30c7\u30fc\u30bf\u30dd\u30a4\u30f3\u30c8\u3092\u5165\u529b\u3057\u307e\u3059\u3002<\/li>\n<li>\u300cStop\u300d\u306fRaw\u30c7\u30fc\u30bf\u306e\u89e3\u6790\u7d42\u4e86\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u306e\u3067\u3001\u3053\u308c\u3067\u89e3\u6790\u7d42\u4e86\u4f4d\u7f6e\u3092\u6307\u5b9a\u3057\u76f4\u3059\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/li>\n<li>\u56f34\u306e\u7d50\u679c\u3067\u3042\u308c\u3070\u3001\u300cStop\u300d\u306b\u300c2548\u300d\u3092\u5165\u529b\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\u624b\u98063\uff1a\u518d\u89e3\u6790\u306e\u5b9f\u884c\n<ul>\n<li>\u8a72\u5f53\u306e\u30b5\u30f3\u30d7\u30eb\u306e\u300cBC\u300d\u306b\u30c1\u30a7\u30c3\u30af\u3092\u3064\u3051\u3001\u7dd1\u306e\u4e09\u89d2\u30dc\u30bf\u30f3\uff08\u300cStart\u300d &gt; \u300cStart Analysis\u300d\uff09\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u518d\u89e3\u6790\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\n<div id=\"attachment_14565\" style=\"width: 1218px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14565\" class=\"size-full wp-image-14565\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-05.png\" alt=\"SeqA\u3067\u306e\u518d\u89e3\u6790\u306e\u5b9f\u884c\" width=\"1208\" height=\"232\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-05.png 1208w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-05-300x58.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-05-1024x197.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-05-768x147.png 768w\" sizes=\"auto, (max-width: 1208px) 100vw, 1208px\" \/><p id=\"caption-attachment-14565\" class=\"wp-caption-text\">\u56f35\uff1aSeqA\u3067\u306e\u518d\u89e3\u6790\u306e\u5b9f\u884c<\/p><\/div>\n<p><div id=\"attachment_14566\" style=\"width: 811px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14566\" class=\"size-full wp-image-14566\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-06.png\" alt=\"SeqA\u3067\u306e\u518d\u89e3\u6790\u5f8c\u753b\u9762\" width=\"801\" height=\"182\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-06.png 801w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-06-300x68.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-06-768x175.png 768w\" sizes=\"auto, (max-width: 801px) 100vw, 801px\" \/><p id=\"caption-attachment-14566\" class=\"wp-caption-text\">\u56f36\uff1aSeqA\u3067\u306e\u518d\u89e3\u6790\u5f8c\u753b\u9762<\/p><\/div><\/li>\n<\/ul>\n<p>\u518d\u89e3\u6790\u5f8c\u3001\u300cElectropherogram\u300d\u30bf\u30d6\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u6ce2\u5f62\u3068\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5869\u57fa\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/p>\n<p>\u518d\u89e3\u6790\u3057\u305f\u30d5\u30a1\u30a4\u30eb\u306f\u300cFile\u300d \uff1e \u300cSave Sample\uff08s\uff09\u300d\u3067\u4e0a\u66f8\u304d\u4fdd\u5b58\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/li>\n<\/ul>\n<h2>Quality Check App\u3067\u306e\u518d\u89e3\u6790<\/h2>\n<ul>\n<li>\u624b\u98061\uff1a\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\u306e\u9078\u629e\n<ul>\n<li>\u300cTraces\u300d\u753b\u9762\u306b\u3066\u3001\u518d\u89e3\u6790\u3057\u305f\u3044\u30d5\u30a1\u30a4\u30eb\u306e\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u306b\u30c1\u30a7\u30c3\u30af\u3092\u3064\u3051\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\u624b\u98062\uff1a\u518d\u89e3\u6790\u6761\u4ef6\u306e\u6307\u5b9a\n<ul>\n<li>\u300cBasecall\u300d\u3092\u30af\u30ea\u30c3\u30af\u3057\u307e\u3059\u3002<\/li>\n<li>\u300cEnding base and Calling Ns\u300d\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u300cAt PCR stop\u300d\u306e\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u306b\u30c1\u30a7\u30c3\u30af\u3092\u4ed8\u3051\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<ul>\n<li>\u624b\u98063\uff1a\u518d\u89e3\u6790\u306e\u5b9f\u884c\n<ul>\n<li>\u300cAnalyze\u300d\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u518d\u89e3\u6790\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\n<div id=\"attachment_14567\" style=\"width: 1496px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14567\" class=\"size-full wp-image-14567\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-07.png\" alt=\"QC\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u518d\u89e3\u6790\u306e\u5b9f\u884c\" width=\"1486\" height=\"1068\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-07.png 1486w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-07-300x216.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-07-1024x736.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-07-768x552.png 768w\" sizes=\"auto, (max-width: 1486px) 100vw, 1486px\" \/><p id=\"caption-attachment-14567\" class=\"wp-caption-text\">\u56f37\uff1aQC\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u518d\u89e3\u6790\u306e\u5b9f\u884c<\/p><\/div>\n<p><div id=\"attachment_14568\" style=\"width: 894px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14568\" class=\"size-full wp-image-14568\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-08.png\" alt=\"QC\u3067\u306e\u518d\u89e3\u6790\u5f8c\u753b\u9762\" width=\"884\" height=\"230\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-08.png 884w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-08-300x78.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/data_app_ce_gsd_ts_2-08-768x200.png 768w\" sizes=\"auto, (max-width: 884px) 100vw, 884px\" \/><p id=\"caption-attachment-14568\" class=\"wp-caption-text\">\u56f38\uff1aQC\u3067\u306e\u518d\u89e3\u6790\u5f8c\u753b\u9762<\/p><\/div><\/li>\n<\/ul>\n<p>\u518d\u89e3\u6790\u5f8c\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u30c0\u30d6\u30eb\u30af\u30ea\u30c3\u30af\u3057\u3001\u6ce2\u5f62\u3068\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5869\u57fa\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/p>\n<p>\u89e3\u6790\u3057\u305f\u30d5\u30a1\u30a4\u30eb\u306f\u4ee5\u4e0b\u306e\u624b\u9806\u3067\u51fa\u529b\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u300cActions\u300d \uff1e \u300cExport Traces\u300d\u753b\u9762\u306b\u3066\u3001\u300c*.ab1\u300d\u306b\u30c1\u30a7\u30c3\u30af \uff1e \u300cOK\u300d\u3092\u30af\u30ea\u30c3\u30af<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<h2>\u307e\u3068\u3081<\/h2>\n<ul>\n<li>\u77ed\u3044\u30bf\u30fc\u30b2\u30c3\u30c8\u3092\u9577\u3044\u30e9\u30f3\u30e2\u30b8\u30e5\u30fc\u30eb\u3067\u6cf3\u52d5\u3059\u308b\u3068\u201dNNNNN\u201d\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308b<\/li>\n<li>\u751f\u30c7\u30fc\u30bf\uff08Raw\uff09\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3067\u539f\u56e0\u3092\u63a8\u6e2c\u3067\u304d\u308b<\/li>\n<li>\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u518d\u89e3\u6790\u3059\u308b\u3053\u3068\u3067\u6539\u5584\u3067\u304d\u308b\u5834\u5408\u304c\u3042\u308b<\/li>\n<\/ul>\n<p>\u201cNNNNN\u201d\u3068\u306a\u3063\u305f\u30c7\u30fc\u30bf\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u3001\u4e0a\u8a18\u306e\u624b\u9806\u3092\u305c\u3072\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><b>\u95a2\u9023\u8a18\u4e8b\uff1a<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dne_gsd_ts_1\/?CID=gsd_cap_lcs_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_data_app_ce_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u539f\u7406<\/a><\/b><\/p>\n<h3>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u790e<\/h3>\n<p>\u3053\u306e\u30b1\u30df\u30b9\u30c8\u30ea\u30fc\u30ac\u30a4\u30c9\u3067\u306f\u3001\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u304b\u3089\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u307e\u3067\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u672c\u539f\u7406\u3092\u5b66\u3079\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_lcs_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_data_app_ce_gsd_ts_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u30e9\u30f3\u304c\u7d42\u308f\u308a\u3001\u3044\u3056\u30b7\u30fc\u30b1\u30f3\u30b9\u30c7\u30fc\u30bf\uff08.ab1\uff09\u3092\u958b\u3044\u3066\u307f\u308b\u3068\u3001\u6ce2\u5f62\u306f\u78ba\u8a8d\u3067\u304d\u308b\u3082\u306e\u306e\u3001\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5869\u57fa\u914d\u5217\u304c\u201dNNNNN\u201d\u3060\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f \u3053\u308c\u306f\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u3066\u518d\u5ea6\u89e3\u6790\u3059\u308b<\/p>\n","protected":false},"author":975,"featured_media":12170,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[183],"division":[],"class_list":["post-14556","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-sanger-seq","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01\" \/>\n<meta property=\"og:description\" content=\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u30e9\u30f3\u304c\u7d42\u308f\u308a\u3001\u3044\u3056\u30b7\u30fc\u30b1\u30f3\u30b9\u30c7\u30fc\u30bf\uff08.ab1\uff09\u3092\u958b\u3044\u3066\u307f\u308b\u3068\u3001\u6ce2\u5f62\u306f\u78ba\u8a8d\u3067\u304d\u308b\u3082\u306e\u306e\u3001\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5869\u57fa\u914d\u5217\u304c\u201dNNNNN\u201d\u3060\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f \u3053\u308c\u306f\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u3066\u518d\u5ea6\u89e3\u6790\u3059\u308b\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-06-27T06:13:11+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-18T07:09:39+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"9\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01\",\"datePublished\":\"2023-06-27T06:13:11+00:00\",\"dateModified\":\"2024-09-18T07:09:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/\"},\"wordCount\":174,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_1926191414.jpg\",\"keywords\":[\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/\",\"name\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_1926191414.jpg\",\"datePublished\":\"2023-06-27T06:13:11+00:00\",\"dateModified\":\"2024-09-18T07:09:39+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_1926191414.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/06\\\/shutterstock_1926191414.jpg\",\"width\":1000,\"height\":1000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/data_app_ce_gsd_ts_2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01","og_description":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u30e9\u30f3\u304c\u7d42\u308f\u308a\u3001\u3044\u3056\u30b7\u30fc\u30b1\u30f3\u30b9\u30c7\u30fc\u30bf\uff08.ab1\uff09\u3092\u958b\u3044\u3066\u307f\u308b\u3068\u3001\u6ce2\u5f62\u306f\u78ba\u8a8d\u3067\u304d\u308b\u3082\u306e\u306e\u3001\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5869\u57fa\u914d\u5217\u304c\u201dNNNNN\u201d\u3060\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f \u3053\u308c\u306f\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u3066\u518d\u5ea6\u89e3\u6790\u3059\u308b","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-06-27T06:13:11+00:00","article_modified_time":"2024-09-18T07:09:39+00:00","og_image":[{"width":1000,"height":1000,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"9\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01","datePublished":"2023-06-27T06:13:11+00:00","dateModified":"2024-09-18T07:09:39+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/"},"wordCount":174,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg","keywords":["\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/","name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg","datePublished":"2023-06-27T06:13:11+00:00","dateModified":"2024-09-18T07:09:39+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg","width":1000,"height":1000},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/data_app_ce_gsd_ts_2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u7d50\u679c\u304c\u201cNNNNN\u201d\uff01\uff1f\u305d\u306e\u7d50\u679c\u3001\u518d\u89e3\u6790\u3067\u6539\u5584\u3059\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\uff01"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":183,"label":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg",760,760,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":183,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","slug":"sanger-seq","term_group":0,"term_taxonomy_id":183,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/06\/shutterstock_1926191414.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14556","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=14556"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14556\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12170"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=14556"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=14556"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=14556"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=14556"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}