{"id":14576,"date":"2023-06-29T14:30:01","date_gmt":"2023-06-29T05:30:01","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=14576"},"modified":"2025-08-19T17:37:26","modified_gmt":"2025-08-19T08:37:26","slug":"foreign_material_ft-nir_msd_sales-3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/","title":{"rendered":"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306a\u3069\u306e\u6210\u5206\u306f\u54c1\u8cea\u3092\u6c7a\u5b9a\u3059\u308b\u4e3b\u8981\u306a\u9805\u76ee\u3067\u3059\u3002\u5c0f\u9ea6\u7c89\u306e\u5f93\u6765\u306e\u5b9a\u91cf\u5206\u6790\u306b\u306f\u3001\u719f\u7df4\u3057\u305f\u5206\u6790\u8005\u3084\u5316\u5b66\u85ac\u54c1\u306e\u4f7f\u7528\u304c\u5fc5\u8981\u3067\u3042\u308a\u3001\u8a66\u6599\u306e\u524d\u51e6\u7406\u306b\u6642\u9593\u304c\u304b\u304b\u308a\u3001\u7d50\u679c\u3092\u5f85\u3064\u6642\u9593\u304c\u9577\u304f\u306a\u308b\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u5f93\u6765\u306e\u5206\u6790\u6cd5\u3092\u30d5\u30fc\u30ea\u30a8\u5909\u63db\u8fd1\u8d64\u5916\u5206\u5149\u6cd5\uff08FT-NIR\uff09\u306b\u7f6e\u304d\u63db\u3048\u308b\u3053\u3068\u3067\u3001\u3088\u308a\u8fc5\u901f\u306a\u7d50\u679c\u3068\u6b63\u78ba\u306a\u5b9a\u91cf\u304c\u53ef\u80fd\u3068\u306a\u308a\u3001\u5c0f\u9ea6\u7c89\u304c\u4ed5\u69d8\u306b\u9069\u5408\u3057\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-14581\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"465\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png\" alt=\"\u5199\u771f\uff1aThermo Scientific Antaris II NIR\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\" class=\"wp-image-14581\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png 598w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7-300x233.png 300w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><figcaption class=\"wp-element-caption\">\u5199\u771f\uff1aThermo Scientific Antaris II NIR\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><b>\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059<\/b><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u98df\u54c1\u3001\u98f2\u6599\u306a\u3069\u306e\u88fd\u9020\u73fe\u5834<\/li>\n\n\n\n<li>\u539f\u6599\u53d7\u3051\u5165\u308c\u691c\u67fb\u3001\u88fd\u54c1\u7ba1\u7406\u691c\u67fb\u3067\u6d3b\u8e8d<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u8fd1\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306e\u6e2c\u5b9a\">\u8fd1\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u306e\u6e2c\u5b9a<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7a4d\u5206\u7403\u3092\u5099\u3048\u305fThermo Scientific\u2122 Antaris\u2122 II FT-NIR\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u3092\u7528\u3044\u305f\u62e1\u6563\u53cd\u5c04\u6cd5\u306b\u3088\u308a\u3001\u5c0f\u9ea6\u7c89\u306e\u8fd1\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\u3092\u6e2c\u5b9a\u3057\u307e\u3057\u305f\u3002\u8a66\u6599\u30b9\u30c6\u30fc\u30b8\u306b\u306f\u30b5\u30f3\u30d7\u30eb\u30ab\u30c3\u30d7\u30b9\u30d4\u30ca\u30fc\u3092\u30bb\u30c3\u30c8\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c0f\u9ea6\u7c89\u3092\u8a70\u3081\u305f\u30b5\u30f3\u30d7\u30eb\u30ab\u30c3\u30d7\u3092\u56de\u8ee2\u3055\u305b\u306a\u304c\u3089\u3001\u8a66\u6599\u304b\u3089\u53cd\u5c04\u3057\u3066\u304f\u308b\u62e1\u6563\u53cd\u5c04\u5149\u3092\u7a4d\u5206\u7403\u3067\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u30ab\u30c3\u30d7\u3092\u56de\u8ee2\u3055\u305b\u308b\u3053\u3068\u3067\u30b5\u30f3\u30d7\u30eb\u306b\u7531\u6765\u3059\u308b\u30d0\u30e9\u3064\u304d\u3092\u4f4e\u6e1b\u3057\u3001\u5e73\u5747\u7684\u306a\u62e1\u6563\u53cd\u5c04\u30b9\u30da\u30af\u30c8\u30eb\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u6e2c\u5b9a\u6761\u4ef6\u306f\u6ce2\u6570\u5206\u89e3\u80fd 8 cm<sup>-1<\/sup> \u3001\u7a4d\u7b97\u56de\u657032\u56de\u30011\u56de\u306e\u6e2c\u5b9a\u306f20\u79d2\u4ee5\u5185\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-14591\"><img loading=\"lazy\" decoding=\"async\" width=\"598\" height=\"341\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/29d3bc99193cb0b837fb8cc53f050ae5-1.png\" alt=\"\u5199\u771f\uff1a\u30b5\u30f3\u30d7\u30eb\u30ab\u30c3\u30d7\u30b9\u30d4\u30ca\u30fc\u30a2\u30af\u30bb\u30b5\u30ea\u30fc\" class=\"wp-image-14591\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/29d3bc99193cb0b837fb8cc53f050ae5-1.png 598w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/29d3bc99193cb0b837fb8cc53f050ae5-1-300x171.png 300w\" sizes=\"auto, (max-width: 598px) 100vw, 598px\" \/><figcaption class=\"wp-element-caption\">\u5199\u771f\uff1a\u30b5\u30f3\u30d7\u30eb\u30ab\u30c3\u30d7\u30b9\u30d4\u30ca\u30fc\u30a2\u30af\u30bb\u30b5\u30ea\u30fc<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-14584\"><img loading=\"lazy\" decoding=\"async\" width=\"672\" height=\"277\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/d22e2e7f6c850bd796ba75e555d30c53.png\" alt=\"\u56f3\uff1a\u7a4d\u5206\u7403\u3092\u4f7f\u3063\u305f\u62e1\u6563\u53cd\u5c04\u6e2c\u5b9a\u306e\u6982\u7565\u56f3\" class=\"wp-image-14584\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/d22e2e7f6c850bd796ba75e555d30c53.png 672w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/d22e2e7f6c850bd796ba75e555d30c53-300x124.png 300w\" sizes=\"auto, (max-width: 672px) 100vw, 672px\" \/><figcaption class=\"wp-element-caption\">\u56f3\uff1a\u7a4d\u5206\u7403\u3092\u4f7f\u3063\u305f\u62e1\u6563\u53cd\u5c04\u6e2c\u5b9a\u306e\u6982\u7565\u56f3<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c0f\u9ea6\u7c89\u306e\u7c92\u5b50\u30b5\u30a4\u30ba\u3084\u30b5\u30f3\u30d7\u30eb\u306e\u8a70\u3081\u5177\u5408\u306e\u9055\u3044\u306b\u3088\u3063\u3066\u30b9\u30da\u30af\u30c8\u30eb\u306e\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u304c\u30aa\u30d5\u30bb\u30c3\u30c8\u3057\u307e\u3059\u306e\u3067\u3001\u305d\u306e\u5f71\u97ff\u3092\u8efd\u6e1b\u3059\u308b\u305f\u3081\u306b\u30b9\u30da\u30af\u30c8\u30eb\u306e\u51e6\u7406\u3068\u3057\u3066\u4e00\u6b21\u5fae\u5206\u3068\u6a19\u6e96\u6b63\u898f\u5909\u91cf\uff08SNV\uff09\u51e6\u7406\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-14596\"><img loading=\"lazy\" decoding=\"async\" width=\"525\" height=\"294\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cbf5b9f60da99bf791c0aa12a770f429-2.png\" alt=\"\u56f3\uff1a\u6e2c\u5b9a\u3057\u305f\u5c0f\u9ea6\u7c89\u306e\u8fd1\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\uff081\u6b21\u5fae\u5206\u304a\u3088\u3073SNV\u51e6\u7406\u5f8c\uff09\" class=\"wp-image-14596\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cbf5b9f60da99bf791c0aa12a770f429-2.png 525w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/cbf5b9f60da99bf791c0aa12a770f429-2-300x168.png 300w\" sizes=\"auto, (max-width: 525px) 100vw, 525px\" \/><figcaption class=\"wp-element-caption\">\u56f3\uff1a\u6e2c\u5b9a\u3057\u305f\u5c0f\u9ea6\u7c89\u306e\u8fd1\u8d64\u5916\u30b9\u30da\u30af\u30c8\u30eb\uff081\u6b21\u5fae\u5206\u304a\u3088\u3073SNV\u51e6\u7406\u5f8c\uff09<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5b9a\u91cf\u30e2\u30c7\u30eb\u306e\u4f5c\u6210\">\u5b9a\u91cf\u30e2\u30c7\u30eb\u306e\u4f5c\u6210<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Thermo Scientific\u2122 TQ Analyst\u2122 \u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u3066\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u7070\u5206\u3001\u6c34\u5206\u306e\u5b9a\u91cf\u5206\u6790\u306b\u7528\u3044\u308b\u5b9a\u91cf\u30e2\u30c7\u30eb\u3092\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\uff5e\u5206\u6790\u7cbe\u5ea6\u306e\u9ad8\u3044\u5b9a\u91cf\u30e2\u30c7\u30ebPLS\u6cd5\uff5e<br>PLS\u306f\u6700\u3082\u4f7f\u308f\u308c\u3066\u3044\u308b\u5b9a\u91cf\u30e2\u30c7\u30eb\u306e\u4e00\u3064\u3067\u3001\u5c0f\u9ea6\u7c89\u306e\u30b9\u30da\u30af\u30c8\u30eb\u306b\u4ee3\u8868\u3055\u308c\u308b\u3088\u3046\u306a\u5e45\u5e83\u3044\u30d4\u30fc\u30af\u3084\u91cd\u306a\u308a\u5408\u3063\u305f\u30d4\u30fc\u30af\u3067\u3082\u826f\u597d\u306a\u691c\u91cf\u7dda\u304c\u5f97\u3089\u308c\u308b\u7279\u5fb4\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PLS\u6cd5\u306f\u3001PLS\u56de\u5e30\u5206\u6790\u3068\u3082\u547c\u3070\u308c2\u3064\u306e\u30b9\u30c6\u30c3\u30d7\u3092\u7d4c\u3066\u691c\u91cf\u30e2\u30c7\u30eb\u304c\u4f5c\u6210\u3055\u308c\u307e\u3059\u30021\u3064\u76ee\u306f\u591a\u5909\u91cf\u30c7\u30fc\u30bf\u3067\u3042\u308b\u30b9\u30da\u30af\u30c8\u30eb\u3092\u4e3b\u6210\u5206\u5206\u6790\u3057\u3066\u5909\u6570\u309210\u500b\u7a0b\u5ea6\u306e\u300c\u4e3b\u6210\u5206\u300d\u306b\u8981\u7d04\u3059\u308b\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u30022\u3064\u76ee\u306f\u4e3b\u6210\u5206\u306e\u3046\u3061\u306e\u3044\u304f\u3064\u304b\u3092\u7d44\u307f\u5408\u308f\u305b\u3066\u56de\u5e30\u5206\u6790\u306b\u3088\u308a\u6700\u9069\u306a1\u3064\u306e\u30e2\u30c7\u30eb\u3092\u5c0e\u304d\u51fa\u3059\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u5c0e\u304d\u51fa\u3055\u308c\u305f\u30e2\u30c7\u30eb\u3067\u8a08\u7b97\u3055\u308c\u305f\u8a08\u7b97\u5024\u3068\u5b9f\u6e2c\u5024\u306e\u95a2\u4fc2\u304c\u691c\u91cf\u7dda\u3068\u3057\u3066\u8868\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5b9a\u91cf\u306b\u3064\u3044\u3066\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u691c\u91cf\u7dda\u306e\u4f5c\u6210\">\u691c\u91cf\u7dda\u306e\u4f5c\u6210<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6210\u5206\u306e\u6fc3\u5ea6\u306f\u5f93\u6765\u306e\u4e00\u6b21\u5206\u6790\u6cd5\u306b\u3088\u308a\u6c42\u3081\u305f\u5024\u3092\u5b9f\u6e2c\u5024\u3068\u3057\u3066\u5165\u529b\u3057\u3001PLS\u30e2\u30c7\u30eb\u3092\u4f5c\u6210\u3057\u3066\u691c\u91cf\u7dda\u3092\u5f97\u307e\u3057\u305f\u3002\u76f8\u95a2\u4fc2\u6570\u306f0.998\u3001\u691c\u91cf\u7dda\u306e\u5e73\u5747\u4e8c\u4e57\u8aa4\u5dee\u5e73\u65b9\u6839\uff08RMSEC\uff09\u306f0.114\u3001\u691c\u8a3c\u5f8c\u306e\u5e73\u5747\u4e8c\u4e57\u8aa4\u5dee\u5e73\u65b9\u6839\uff08RMSECV\uff09\u306f0.116\u3068\u826f\u597d\u306a\u7d50\u679c\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-14586\"><img loading=\"lazy\" decoding=\"async\" width=\"538\" height=\"253\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/00455c855f00ac7c3198e622f91d3f20.png\" alt=\"\u30b0\u30e9\u30d5\uff1a\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u691c\u91cf\u7dda\" class=\"wp-image-14586\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/00455c855f00ac7c3198e622f91d3f20.png 538w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/00455c855f00ac7c3198e622f91d3f20-300x141.png 300w\" sizes=\"auto, (max-width: 538px) 100vw, 538px\" \/><figcaption class=\"wp-element-caption\">\u56f3\uff1a\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u691c\u91cf\u7dda<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u56de\u5e30\u30e2\u30c7\u30eb\u306b\u4f7f\u3046\u30d5\u30a1\u30af\u30bf\u30fc\u6570\">\u56de\u5e30\u30e2\u30c7\u30eb\u306b\u4f7f\u3046\u30d5\u30a1\u30af\u30bf\u30fc\u6570<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">10\u500b\u7a0b\u5ea6\u306b\u8981\u7d04\u3055\u308c\u305f\u4e3b\u6210\u5206\u3067\u3059\u304c\u3001\u6700\u9069\u306a\u6570\u3092\u6c7a\u5b9a\u3059\u308b\u305f\u3081\u306b\u3001\u4e88\u6e2c\u6b8b\u5dee\u5e73\u65b9\u548c\uff08Predicted Residual Error Sum of Squares, PRESS\uff09\u30d7\u30ed\u30c3\u30c8\u3092\u898b\u3066\u307f\u307e\u3059\u3002PRESS\u30d7\u30ed\u30c3\u30c8\u306f\u30d5\u30a1\u30af\u30bf\u30fc\u6570\u306e\u5897\u52a0\u306b\u95a2\u3059\u308b\u4e88\u6e2c\u7cbe\u5ea6\u306e\u5909\u5316\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u8aa4\u5dee\u304c\u5341\u5206\u306b\u5c0f\u3055\u304f\u306a\u308b\u3088\u3046\u306a\u6700\u5c11\u306e\u30d5\u30a1\u30af\u30bf\u30fc\u6570\u3092\u9078\u629e\u3057\u30e2\u30c7\u30eb\u3092\u6700\u9069\u5316\u3057\u307e\u3059\u3002\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u304c\u6700\u9069\u306a\u6570\u3092\u81ea\u52d5\u3067\u9078\u629e\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-14587\"><img loading=\"lazy\" decoding=\"async\" width=\"537\" height=\"319\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/e933a21e6f8c1433ee324f7d64d52121.png\" alt=\"\u30b0\u30e9\u30d5\uff1aPRESS\u30d7\u30ed\u30c3\u30c8\uff08\u4e3b\u6210\u5206\u6570\u306e\u5897\u52a0\u306b\u3088\u308b\u4e88\u6e2c\u7cbe\u5ea6\u306e\u5909\u5316\uff09\" class=\"wp-image-14587\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/e933a21e6f8c1433ee324f7d64d52121.png 537w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/e933a21e6f8c1433ee324f7d64d52121-300x178.png 300w\" sizes=\"auto, (max-width: 537px) 100vw, 537px\" \/><figcaption class=\"wp-element-caption\">\u56f3\uff1aPRESS\u30d7\u30ed\u30c3\u30c8\uff08\u4e3b\u6210\u5206\u6570\u306e\u5897\u52a0\u306b\u3088\u308b\u4e88\u6e2c\u7cbe\u5ea6\u306e\u5909\u5316\uff09<br>\u6a2a\u8ef8\u306f\u4e3b\u6210\u5206\u6570\u3001\u7e26\u8ef8\u306f\u4e8c\u4e57\u5e73\u5747\u5e73\u65b9\u6839\u8aa4\u5dee\uff08RMSE\uff09<\/figcaption><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u8996\u899a\u7684\u30c4\u30fc\u30eb\u306e\u6d3b\u7528\">\u8996\u899a\u7684\u30c4\u30fc\u30eb\u306e\u6d3b\u7528<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">TQ Analyst\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u3001\u5916\u308c\u5024\u3001\u50be\u5411\u3001\u30d1\u30bf\u30fc\u30f3\u3092\u7279\u5b9a\u3059\u308b\u305f\u3081\u306e\u8996\u899a\u7684\u30c4\u30fc\u30eb\u3068\u3057\u3066\u30012\u6b21\u5143\uff082D\uff09\u30683\u6b21\u5143\uff083D\uff09\u306e\u4e3b\u6210\u5206\u30b9\u30b3\u30a2\u30d7\u30ed\u30c3\u30c8\u306e\u8868\u793a\u304c\u3067\u304d\u307e\u3059\u3002\u4e0b\u8a18\u306b3D\u30b9\u30b3\u30a2\u30d7\u30ed\u30c3\u30c8\u3092\u793a\u3057\u307e\u3059\u3002\u5206\u6790\u8005\u306f\u3069\u306e\u4e3b\u6210\u5206\u304c\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u6700\u3082\u76f8\u95a2\u304c\u3042\u308b\u304b\u3092\u8996\u899a\u7684\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-14588\"><img loading=\"lazy\" decoding=\"async\" width=\"537\" height=\"475\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/ce7e1ed1afbf5b4fe01244bfbccfb5c0.png\" alt=\"\u30b0\u30e9\u30d5\uff1a3D\u4e3b\u6210\u5206\u30b9\u30b3\u30a2\u30d7\u30ed\u30c3\u30c8\" class=\"wp-image-14588\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/ce7e1ed1afbf5b4fe01244bfbccfb5c0.png 537w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/ce7e1ed1afbf5b4fe01244bfbccfb5c0-300x265.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/ce7e1ed1afbf5b4fe01244bfbccfb5c0-310x274.png 310w\" sizes=\"auto, (max-width: 537px) 100vw, 537px\" \/><figcaption class=\"wp-element-caption\">\u56f3\uff1a3D\u4e3b\u6210\u5206\u30b9\u30b3\u30a2\u30d7\u30ed\u30c3\u30c8<br>\u4e3b\u6210\u52061\uff08PC1\uff09\u3068\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u6e2c\u5024\u306e\u9593\u306b\u9ad8\u3044\u76f8\u95a2\u304c\u3042\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/figcaption><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5c0f\u9ea6\u7c89\u306e\u5b9a\u91cf\u30e2\u30c7\u30eb\u4f5c\u6210\u306b\u3088\u308a\u3001FT-NIR \u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u304c\u5c0f\u9ea6\u7c89\u306e\u4e3b\u8981\u6210\u5206\u3067\u3042\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6b63\u78ba\u306b\u5b9a\u91cf\u3067\u304d\u308b\u3053\u3068\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002TQ Analyst\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u691c\u91cf\u7dda\u306e\u307b\u304b\u3001PRESS\u30d7\u30ed\u30c3\u30c8\u30013D\u4e3b\u6210\u5206\u30b9\u30b3\u30a2\u30d7\u30ed\u30c3\u30c8\u306a\u3069\u8996\u899a\u7684\u306a\u8a3a\u65ad\u30c4\u30fc\u30eb\u306b\u3088\u308a\u3001\u5b9a\u91cf\u30e2\u30c7\u30eb\u306e\u6700\u9069\u5316\u304c\u3067\u304d\u307e\u3059\u3002FT-NIR\u3067\u306e\u5206\u6790\u306f\u3001\u5316\u5b66\u85ac\u54c1\u3092\u4f7f\u7528\u305b\u305a\u306b\u7c21\u5358\u306b\u3001\u3088\u308a\u901f\u304f\u3001\u6b63\u78ba\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0\u3067\u54c1\u8cea\u60c5\u5831\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u3067\u3001\u751f\u7523\u52b9\u7387\u3068\u53ce\u76ca\u6027\u3092\u9ad8\u3081\u308b\u3053\u3068\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8<br><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/AN52269-wheat-flour-protein-moisture-ash-analysis-ft-nir.pdf?CID=foreign_material_ft-nir_msd_sales_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/AN52269-wheat-flour-protein-moisture-ash-analysis-ft-nir.pdf<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Thermo Fisher Scientific\u304c\u8ca9\u58f2\u3057\u3066\u3044\u308bFT-NIR\u306e\u8a73\u7d30\u306f\u4e0b\u8a18\u3092\u3054\u3089\u3093\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/MSD\/brochures\/br-034-ftir-antaris-analyzer-br034.pdf?CID=foreign_material_ft-nir_msd_sales_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u88fd\u54c1\u60c5\u5831<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/near-infrared-spectroscopy.html?CID=foreign_material_ft-nir_msd_sales_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u8fd1\u8d64\u5916\u5206\u5149\u6cd5\u306e\u6982\u8981<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/near-infrared-spectroscopy\/applications.html?CID=foreign_material_ft-nir_msd_sales_3_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u8fd1\u8d64\u5916\u5206\u5149\u6cd5\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/a><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><b>FT-NIR\u88fd\u54c1\u306b\u3064\u3044\u3066\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u3092\u304a\u5f85\u3061\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/b><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/near-infrared-spectroscopy.html?CID=foreign_material_ft-nir_msd_sales_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306a\u3069\u306e\u6210\u5206\u306f\u54c1\u8cea\u3092\u6c7a\u5b9a\u3059\u308b\u4e3b\u8981\u306a\u9805\u76ee\u3067\u3059\u3002\u5c0f\u9ea6\u7c89\u306e\u5f93\u6765\u306e\u5b9a\u91cf\u5206\u6790\u306b\u306f\u3001\u719f\u7df4\u3057\u305f\u5206\u6790\u8005\u3084\u5316\u5b66\u85ac\u54c1\u306e\u4f7f\u7528\u304c\u5fc5\u8981\u3067\u3042\u308a\u3001\u8a66\u6599\u306e\u524d\u51e6\u7406\u306b\u6642\u9593\u304c\u304b\u304b\u308a\u3001\u7d50\u679c\u3092\u5f85\u3064\u6642\u9593\u304c\u9577\u304f\u306a\u308b\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u308a\u307e\u3057\u305f\u3002<\/p>\n","protected":false},"author":975,"featured_media":14581,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[210],"division":[],"class_list":["post-14576","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-nir","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"FT-NIR\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306a\u5206\u6790\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u4e00\u8cab\u6027\u3068\u54c1\u8cea\u7ba1\u7406\u306b\u6700\u9069\u3067\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790\" \/>\n<meta property=\"og:description\" content=\"FT-NIR\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306a\u5206\u6790\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u4e00\u8cab\u6027\u3068\u54c1\u8cea\u7ba1\u7406\u306b\u6700\u9069\u3067\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-06-29T05:30:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-19T08:37:26+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png\" \/>\n\t<meta property=\"og:image:width\" content=\"598\" \/>\n\t<meta property=\"og:image:height\" content=\"465\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790\",\"datePublished\":\"2023-06-29T05:30:01+00:00\",\"dateModified\":\"2025-08-19T08:37:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/\"},\"wordCount\":65,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/f2c8be32b69ae5c04902ce3fc373c8f7.png\",\"keywords\":[\"\u8fd1\u8d64\u5916\u5206\u5149\u6cd5\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/\",\"name\":\"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/f2c8be32b69ae5c04902ce3fc373c8f7.png\",\"datePublished\":\"2023-06-29T05:30:01+00:00\",\"dateModified\":\"2025-08-19T08:37:26+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"description\":\"FT-NIR\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306a\u5206\u6790\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u4e00\u8cab\u6027\u3068\u54c1\u8cea\u7ba1\u7406\u306b\u6700\u9069\u3067\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/f2c8be32b69ae5c04902ce3fc373c8f7.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/06\\\/f2c8be32b69ae5c04902ce3fc373c8f7.png\",\"width\":598,\"height\":465,\"caption\":\"\u5199\u771f\uff1aThermo Scientific Antaris II NIR\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_ft-nir_msd_sales-3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790 - Learning at the Bench","description":"FT-NIR\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306a\u5206\u6790\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u4e00\u8cab\u6027\u3068\u54c1\u8cea\u7ba1\u7406\u306b\u6700\u9069\u3067\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/","og_locale":"ja_JP","og_type":"article","og_title":"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790","og_description":"FT-NIR\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306a\u5206\u6790\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u4e00\u8cab\u6027\u3068\u54c1\u8cea\u7ba1\u7406\u306b\u6700\u9069\u3067\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-06-29T05:30:01+00:00","article_modified_time":"2025-08-19T08:37:26+00:00","og_image":[{"width":598,"height":465,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790","datePublished":"2023-06-29T05:30:01+00:00","dateModified":"2025-08-19T08:37:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/"},"wordCount":65,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png","keywords":["\u8fd1\u8d64\u5916\u5206\u5149\u6cd5"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/","name":"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png","datePublished":"2023-06-29T05:30:01+00:00","dateModified":"2025-08-19T08:37:26+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"description":"FT-NIR\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u8fc5\u901f\u304b\u3064\u6b63\u78ba\u306a\u5206\u6790\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u88fd\u54c1\u306e\u4e00\u8cab\u6027\u3068\u54c1\u8cea\u7ba1\u7406\u306b\u6700\u9069\u3067\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png","width":598,"height":465,"caption":"\u5199\u771f\uff1aThermo Scientific Antaris II NIR\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_ft-nir_msd_sales-3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"FT-NIR\uff08\u8fd1\u8d64\u5916\u5206\u5149\u5206\u6790\u6cd5\uff09\u3092\u7528\u3044\u305f\u5c0f\u9ea6\u7c89\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3001\u6c34\u5206\u3001\u7070\u5206\u306e\u5206\u6790"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":210,"label":"\u8fd1\u8d64\u5916\u5206\u5149\u6cd5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png",598,465,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":106,"filter":"raw","meta":[],"cat_ID":157,"category_count":106,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":210,"name":"\u8fd1\u8d64\u5916\u5206\u5149\u6cd5","slug":"nir","term_group":0,"term_taxonomy_id":210,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/06\/f2c8be32b69ae5c04902ce3fc373c8f7.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=14576"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14576\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/14581"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=14576"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=14576"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=14576"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=14576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}