{"id":14608,"date":"2023-07-04T11:21:27","date_gmt":"2023-07-04T02:21:27","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=14608"},"modified":"2025-04-15T16:06:02","modified_gmt":"2025-04-15T07:06:02","slug":"qpcr_workshop_gsd_ts_3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u5f53\u793e\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u306fFast\u30e2\u30fc\u30c9\u3068Standard\u30e2\u30fc\u30c9\u306e2\u7a2e\u985e\u306e\u30e9\u30f3\u30e2\u30fc\u30c9\u304c\u3042\u308a\u307e\u3059\u3002\u71b1\u5909\u6027\u306e\u30b9\u30c6\u30c3\u30d7\u3084\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u30fb\u4f38\u9577\u53cd\u5fdc\u30b9\u30c6\u30c3\u30d7\u306e\u53cd\u5fdc\u6642\u9593\u3068\u6e29\u5ea6\u306e\u4e0a\u3052\u4e0b\u3052\u306e\u30b9\u30d4\u30fc\u30c9\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081Fast\u30e2\u30fc\u30c9\u3067\u306f\u7d0430\u5206\u3001Standard\u30e2\u30fc\u30c9\u3067\u306f\u7d041\u6642\u9593\u534a\u3068\u30e9\u30f3\u6642\u9593\u304c\u5927\u304d\u304f\u5909\u308f\u308a\u307e\u3059\u3002Fast\u30e2\u30fc\u30c9\u306f\u30e9\u30f3\u6642\u9593\u304c\u77ed\u3044\u53cd\u9762\u3001\u77ed\u3044\u53cd\u5fdc\u6642\u9593\u3067\u554f\u984c\u304c\u306a\u3044\u306e\u304b\u4e0d\u5b89\u306b\u601d\u3046\u65b9\u3082\u3044\u3089\u3063\u3057\u3083\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u5b9f\u969b\u306b\u300c\u4f38\u9577\u53cd\u5fdc20\u79d2\u3067\u672c\u5f53\u306b\u5927\u4e08\u592b\uff1f\u300d\u3068\u3054\u8cea\u554f\u3092\u3046\u3051\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306e\u8a18\u4e8b\u3067\u306fFast\u30e2\u30fc\u30c9\u306e\u8a66\u85ac\u3092\u3042\u3048\u3066Standard\u30e2\u30fc\u30c9\u3067\u30e9\u30f3\u3057\u3001\u7d50\u679c\u306b\u5dee\u304c\u3042\u308b\u306e\u304b\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n<p>\u3053\u3093\u306a\u65b9\u306b\u304a\u52e7\u3081\u3067\u3059\u3002<\/p>\n<ul>\n<li>\u30e9\u30f3\u30e2\u30fc\u30c9\u306e\u9078\u629e\u306b\u8ff7\u3063\u3066\u3044\u308b\u65b9<\/li>\n<li>Fast\u30e2\u30fc\u30c9\u3067\u5341\u5206\u306bPCR\u53cd\u5fdc\u304c\u9032\u3093\u3067\u3044\u308b\u306e\u304b\u4e0d\u5b89\u306a\u65b9<\/li>\n<li>Fast\u30e2\u30fc\u30c9\u306e\u8a66\u85ac\u3092\u691c\u8a0e\u3055\u308c\u3066\u3044\u308b\u65b9<\/li>\n<\/ul>\n<h2>\u6750\u6599\u3068\u65b9\u6cd5<\/h2>\n<p>Fast\u30e2\u30fc\u30c9\u7528\u8a66\u85ac\u3068\u3057\u3066Applied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4444556?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">TaqMan\u2122 Fast Advanced Master Mix<\/a>\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u88fd\u54c1\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u5f93\u304420 \u00b5L\u5bb9\u91cf\u306e\u53cd\u5fdc\u6db2\u3092\u8abf\u88fd\u3057\u307e\u3057\u305f\u300250 ng\/well\u306b\u8abf\u88fd\u3055\u308c\u305fcDNA\u30924\u500d\u3082\u3057\u304f\u306f3\u500d\u5e0c\u91c8\u3057\u8a086\u70b9\u306e\u5e0c\u91c8\u7cfb\u5217\u3092\u4f5c\u6210\u3001\u92f3\u578b\u3068\u3057\u3066\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u30ec\u30d7\u30ea\u30b1\u30fc\u30c8\u306f3\u3068\u3057\u307e\u3057\u305f\u3002Applied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-assays.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">TaqMan\u2122 Gene Expression Assay<\/a> (20x) \u3092\u3082\u3061\u3044\u3066GAPDH\u3001ACTB\u3001IL-8\u3001COL1A1\u3001ACTA2\u3001ALDHA1\u306e6\u3064\u306e\u907a\u4f1d\u5b50\u3092\u6e2c\u5b9a\u3057\u307e\u3057\u305f\u3002\u53cd\u5fdc\u6761\u4ef6\u306f\u4e0b\u8a18\u306e\u901a\u308a\u3067\u3059\uff08\u56f3\uff11\u3001\u56f32\uff09\u3002\u88c5\u7f6e\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-instruments\/quantstudio-systems\/models\/quantstudio-6-7-pro.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Applied Biosystems\u2122 QuantStudio\u2122 7 Pro\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30b7\u30b9\u30c6\u30e0<\/a>\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002<\/p>\n<p>Standard\u30e2\u30fc\u30c9\u306e\u30d7\u30ed\u30b0\u30e9\u30e0 \u30e9\u30f3\u6240\u8981\u6642\u9593\u20261\u6642\u959321\u5206<\/p>\n<div id=\"attachment_14610\" style=\"width: 494px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14610\" class=\"size-full wp-image-14610\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-01.png\" alt=\"Standard\u30e2\u30fc\u30c9\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\" width=\"484\" height=\"371\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-01.png 484w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-01-300x230.png 300w\" sizes=\"auto, (max-width: 484px) 100vw, 484px\" \/><p id=\"caption-attachment-14610\" class=\"wp-caption-text\">\u56f31\uff0eStandard\u30e2\u30fc\u30c9\u306e\u30d7\u30ed\u30b0\u30e9\u30e0<\/p><\/div>\n<p>Fast\u30e2\u30fc\u30c9\u306e\u30d7\u30ed\u30b0\u30e9\u30e0 \u30e9\u30f3\u6240\u8981\u6642\u9593\u202632\u5206<\/p>\n<div id=\"attachment_14611\" style=\"width: 484px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14611\" class=\"size-full wp-image-14611\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-02.png\" alt=\"Fast\u30e2\u30fc\u30c9\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\" width=\"474\" height=\"366\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-02.png 474w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-02-300x232.png 300w\" sizes=\"auto, (max-width: 474px) 100vw, 474px\" \/><p id=\"caption-attachment-14611\" class=\"wp-caption-text\">\u56f32\uff0eFast\u30e2\u30fc\u30c9\u306e\u30d7\u30ed\u30b0\u30e9\u30e0<\/p><\/div>\n<h2>\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n<p>\u305d\u308c\u3067\u306f\u65e9\u901f\u7d50\u679c\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<br \/>\n\u5404\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u3054\u3068\u306bcDNA\u91cf\u3092\u6a2a\u8ef8\u3001Ct\u5024\u3092\u7e26\u8ef8\u306b\u30d7\u30ed\u30c3\u30c8\u3057\u307e\u3057\u305f\u3002Standard\u30e2\u30fc\u30c9\u306e\u9752\u3044\u30d7\u30ed\u30c3\u30c8\u3068Fast\u30e2\u30fc\u30c9\u306e\u30aa\u30ec\u30f3\u30b8\u306e\u30d7\u30ed\u30c3\u30c8\u306f\u975e\u5e38\u306b\u3088\u304f\u4e00\u81f4\u3057\u307e\u3057\u305f\uff08\u56f33\uff09\u3002\u30c6\u30af\u30cb\u30ab\u30eb\u30ec\u30d7\u30ea\u30b1\u30fc\u30c8\u306e3\u30a6\u30a7\u30eb\u306e\u5e73\u5747\u5024\u3092\u6bd4\u8f03\u3057\u3066\u3082\u5dee\u306f\u308f\u305a\u304b\u3067\u3057\u305f\uff08\u88681\uff09\u3002<\/p>\n<div id=\"attachment_14609\" style=\"width: 1004px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-14609\" class=\"size-full wp-image-14609\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-03.png\" alt=\"Ct\u5024\u306e\u30d7\u30ed\u30c3\u30c8\u56f3\" width=\"994\" height=\"905\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-03.png 994w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-03-300x273.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/qpcr_workshop_gsd_ts_3-03-768x699.png 768w\" sizes=\"auto, (max-width: 994px) 100vw, 994px\" \/><p id=\"caption-attachment-14609\" class=\"wp-caption-text\">\u56f33\uff0eCt\u5024\u306e\u30d7\u30ed\u30c3\u30c8\u56f3<\/p><\/div>\n<table width=\"342\">\n<caption><b>\u88681\uff0e\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3051\u308bCt\u5024\u306e\u5e73\u5747\u5024<\/b><\/caption>\n<tbody>\n<tr bgcolor=\"aliceblue\">\n<td width=\"78\">ACTB<\/td>\n<td width=\"44\">S1<\/td>\n<td width=\"44\">S2<\/td>\n<td width=\"44\">S3<\/td>\n<td width=\"44\">S4<\/td>\n<td width=\"44\">S5<\/td>\n<td width=\"44\">S6<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Fast<\/td>\n<td width=\"44\">17.3<\/td>\n<td width=\"44\">19.1<\/td>\n<td width=\"44\">21.2<\/td>\n<td width=\"44\">23.3<\/td>\n<td width=\"44\">25.4<\/td>\n<td width=\"44\">27.5<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Standard<\/td>\n<td width=\"44\">17.0<\/td>\n<td width=\"44\">19.2<\/td>\n<td width=\"44\">21.3<\/td>\n<td width=\"44\">23.3<\/td>\n<td width=\"44\">25.4<\/td>\n<td width=\"44\">27.5<\/td>\n<\/tr>\n<tr>\n<td width=\"78\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<\/tr>\n<tr bgcolor=\"aliceblue\">\n<td width=\"78\">GAPDH<\/td>\n<td width=\"44\">S1<\/td>\n<td width=\"44\">S2<\/td>\n<td width=\"44\">S3<\/td>\n<td width=\"44\">S4<\/td>\n<td width=\"44\">S5<\/td>\n<td width=\"44\">S6<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Fast<\/td>\n<td width=\"44\">16.9<\/td>\n<td width=\"44\">19.0<\/td>\n<td width=\"44\">21.0<\/td>\n<td width=\"44\">23.2<\/td>\n<td width=\"44\">25.3<\/td>\n<td width=\"44\">27.5<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Standard<\/td>\n<td width=\"44\">16.8<\/td>\n<td width=\"44\">18.9<\/td>\n<td width=\"44\">20.9<\/td>\n<td width=\"44\">23.1<\/td>\n<td width=\"44\">25.2<\/td>\n<td width=\"44\">27.4<\/td>\n<\/tr>\n<tr>\n<td width=\"78\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<\/tr>\n<tr bgcolor=\"aliceblue\">\n<td width=\"78\">IL-8<\/td>\n<td width=\"44\">S1<\/td>\n<td width=\"44\">S2<\/td>\n<td width=\"44\">S3<\/td>\n<td width=\"44\">S4<\/td>\n<td width=\"44\">S5<\/td>\n<td width=\"44\">S6<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Fast<\/td>\n<td width=\"44\">24.5<\/td>\n<td width=\"44\">26.7<\/td>\n<td width=\"44\">28.8<\/td>\n<td width=\"44\">30.8<\/td>\n<td width=\"44\">33.0<\/td>\n<td width=\"44\">34.9<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Standard<\/td>\n<td width=\"44\">24.2<\/td>\n<td width=\"44\">26.4<\/td>\n<td width=\"44\">28.3<\/td>\n<td width=\"44\">30.4<\/td>\n<td width=\"44\">32.3<\/td>\n<td width=\"44\">34.8<\/td>\n<\/tr>\n<tr>\n<td width=\"78\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<\/tr>\n<tr bgcolor=\"aliceblue\">\n<td width=\"78\">COL1A1<\/td>\n<td width=\"44\">S1<\/td>\n<td width=\"44\">S2<\/td>\n<td width=\"44\">S3<\/td>\n<td width=\"44\">S4<\/td>\n<td width=\"44\">S5<\/td>\n<td width=\"44\">S6<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Fast<\/td>\n<td width=\"44\">22.8<\/td>\n<td width=\"44\">24.4<\/td>\n<td width=\"44\">26.0<\/td>\n<td width=\"44\">27.6<\/td>\n<td width=\"44\">29.4<\/td>\n<td width=\"44\">30.8<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Standard<\/td>\n<td width=\"44\">23.2<\/td>\n<td width=\"44\">24.8<\/td>\n<td width=\"44\">26.4<\/td>\n<td width=\"44\">28.0<\/td>\n<td width=\"44\">29.6<\/td>\n<td width=\"44\">31.2<\/td>\n<\/tr>\n<tr>\n<td width=\"78\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<\/tr>\n<tr bgcolor=\"aliceblue\">\n<td width=\"78\">ACTA2<\/td>\n<td width=\"44\">S1<\/td>\n<td width=\"44\">S2<\/td>\n<td width=\"44\">S3<\/td>\n<td width=\"44\">S4<\/td>\n<td width=\"44\">S5<\/td>\n<td width=\"44\">S6<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Fast<\/td>\n<td width=\"44\">25.2<\/td>\n<td width=\"44\">26.8<\/td>\n<td width=\"44\">28.6<\/td>\n<td width=\"44\">30.3<\/td>\n<td width=\"44\">32.0<\/td>\n<td width=\"44\">33.5<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Standard<\/td>\n<td width=\"44\">25.3<\/td>\n<td width=\"44\">26.9<\/td>\n<td width=\"44\">28.6<\/td>\n<td width=\"44\">30.3<\/td>\n<td width=\"44\">31.9<\/td>\n<td width=\"44\">33.7<\/td>\n<\/tr>\n<tr>\n<td width=\"78\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<td width=\"44\"><\/td>\n<\/tr>\n<tr bgcolor=\"aliceblue\">\n<td width=\"78\">ALDH1A1<\/td>\n<td width=\"44\">S1<\/td>\n<td width=\"44\">S2<\/td>\n<td width=\"44\">S3<\/td>\n<td width=\"44\">S4<\/td>\n<td width=\"44\">S5<\/td>\n<td width=\"44\">S6<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Fast<\/td>\n<td width=\"44\">23.7<\/td>\n<td width=\"44\">25.4<\/td>\n<td width=\"44\">27.1<\/td>\n<td width=\"44\">28.7<\/td>\n<td width=\"44\">30.3<\/td>\n<td width=\"44\">31.9<\/td>\n<\/tr>\n<tr>\n<td width=\"78\">Standard<\/td>\n<td width=\"44\">23.7<\/td>\n<td width=\"44\">25.4<\/td>\n<td width=\"44\">27.1<\/td>\n<td width=\"44\">28.6<\/td>\n<td width=\"44\">30.2<\/td>\n<td width=\"44\">32.1<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u691c\u91cf\u7dda\u306e\u7cbe\u5ea6\u3092\u3042\u3089\u308f\u3059R\u306e2\u4e57\u5024\u3084\u5897\u5e45\u52b9\u7387\u306b\u3064\u3044\u3066\u975e\u5e38\u306b\u8fd1\u3044\u5024\u3068\u306a\u308a\u307e\u3057\u305f\uff08\u88682\uff09\u3002\u53cd\u5fdc\u6642\u9593\u304c\u77ed\u7e2e\u3055\u308c\u305fFast\u30e2\u30fc\u30c9\u3067\u3082Standard\u30e2\u30fc\u30c9\u3068\u540c\u7b49\u306e\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002Fast\u30e2\u30fc\u30c9\u3067\u3082PCR\u53cd\u5fdc\u304c\u5341\u5206\u306b\u9032\u3080\u3068\u5206\u304b\u308a\u307e\u3057\u305f\u3002<br \/>\n\u203b\u304a\u4f7f\u3044\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u30bb\u30c3\u30c8\u3001TaqMan Assay\u306b\u3088\u3063\u3066\u306f\u30e9\u30f3\u30e2\u30fc\u30c9\u306b\u3088\u308b\u5f71\u97ff\u304c\u3067\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<table width=\"387\">\n<caption><b>\u88682\uff0e\u691c\u91cf\u7dda\u304b\u3089\u7b97\u51fa\u3055\u308c\u305fPCR\u52b9\u7387\u3068R2\u5024<\/b><\/caption>\n<tbody>\n<tr>\n<td width=\"72\"><\/td>\n<td style=\"text-align: center\" colspan=\"2\" width=\"157\">Fast\u30e2\u30fc\u30c9<\/td>\n<td style=\"text-align: center\" colspan=\"2\" width=\"157\">Standard\u30e2\u30fc\u30c9<\/td>\n<\/tr>\n<tr>\n<td width=\"72\"><\/td>\n<td width=\"106\">PCR\u52b9\u7387(%)<\/td>\n<td width=\"51\">R<sup>2<\/sup><\/td>\n<td width=\"106\">PCR\u52b9\u7387(%)<\/td>\n<td width=\"51\">R<sup>2<\/sup><\/td>\n<\/tr>\n<tr>\n<td width=\"72\">ACTB<\/td>\n<td width=\"106\">95.99<\/td>\n<td width=\"51\">1.000<\/td>\n<td width=\"106\">93.95<\/td>\n<td width=\"51\">1.000<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">GAPDH<\/td>\n<td width=\"106\">92.28<\/td>\n<td width=\"51\">1.000<\/td>\n<td width=\"106\">92.12<\/td>\n<td width=\"51\">1.000<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">IL-8<\/td>\n<td width=\"106\">94.44<\/td>\n<td width=\"51\">0.998<\/td>\n<td width=\"106\">95.34<\/td>\n<td width=\"51\">0.995<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">COL1A1<\/td>\n<td width=\"106\">99.02<\/td>\n<td width=\"51\">1.000<\/td>\n<td width=\"106\">96.26<\/td>\n<td width=\"51\">0.997<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">ACTA2<\/td>\n<td width=\"106\">92.41<\/td>\n<td width=\"51\">0.994<\/td>\n<td width=\"106\">91.88<\/td>\n<td width=\"51\">0.998<\/td>\n<\/tr>\n<tr>\n<td width=\"72\">ALDHA1<\/td>\n<td width=\"106\">94.25<\/td>\n<td width=\"51\">0.997<\/td>\n<td width=\"106\">92.12<\/td>\n<td width=\"51\">0.999<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Fast\u30e2\u30fc\u30c9\u5bfe\u5fdc\u8a66\u85ac\u306e\u3054\u7d39\u4ecb<\/h2>\n<p>\u6700\u5f8c\u306b\u3001\u5f53\u793e\u3067\u304a\u3059\u3059\u3081\u3057\u3066\u3044\u308bFast\u30e2\u30fc\u30c9\u5bfe\u5fdc\u306eMaster Mix\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002TaqMan Assay\u5b9f\u9a13\u7cfb\u306e\u304a\u3059\u3059\u3081\u88fd\u54c1\u3067\u3001\u691c\u51fa\u611f\u5ea6\u3001\u7cbe\u5ea6\u3001\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u3001\u7279\u7570\u6027\u306b\u512a\u308c\u307e\u3059\u3002\u4eca\u56de\u306e\u5b9f\u9a13\u3067\u3082\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/jp\/ja\/4444556?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">TaqMan Fast Advanced Master Mix<\/a><\/p>\n<p>SYBR\u2122 Green\u5b9f\u9a13\u7cfb\u306e\u304a\u3059\u3059\u3081\u88fd\u54c1\u3067\u3059\u3002Fast\u30e2\u30fc\u30c9\u306b\u5bfe\u5fdc\u3057\u3066\u304a\u308a\u3001\u7279\u7570\u6027\u3082\u9ad8\u3044\u8a66\u85ac\u3067\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A25741?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Applied Biosystems\u2122 PowerUp\u2122 SYBR\u2122 Green Master Mix<\/a><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306eFast\u30e2\u30fc\u30c9\u3068Standard\u30e2\u30fc\u30c9\u306e\u3069\u3061\u3089\u3092\u4f7f\u3063\u3066\u3082\u7d50\u679c\u306b\u5dee\u304c\u51fa\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u3082\u3057\u3001Fast\u30e2\u30fc\u30c9\u5bfe\u5fdc\u306e\u8a66\u85ac\u3092\u304a\u4f7f\u3044\u306e\u5834\u5408\u306f\u3001\u30e9\u30f3\u6642\u9593\u30921\u6642\u9593\u307b\u3069\u77ed\u304f\u3067\u304d\u307e\u3059\u306e\u3067\u3001\u305c\u3072Fast\u30e2\u30fc\u30c9\u3067\u6e2c\u5b9a\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u5f53\u793e\u3067\u306fRNA\u62bd\u51fa\u3084\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3001\u4ed6\u306b\u3082\u7d30\u80de\u57f9\u990a\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306a\u3069\u3001\u5b9f\u969b\u306b\u5b9f\u9a13\uff08\u5b9f\u7fd2\uff09\u3092\u884c\u3044\u3064\u3064\u5b66\u3079\u308b\u5404\u7a2e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3092\u958b\u50ac\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4e2d\u3067\u4eca\u56de\u306e\u3088\u3046\u306a\u5b9f\u9a13\u7d50\u679c\u3082\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u3053\u308c\u304b\u3089\u65b0\u3057\u3044\u5b9f\u9a13\u3092\u59cb\u3081\u3089\u308c\u308b\u65b9\u3001\u3088\u308a\u7406\u89e3\u3092\u6df1\u3081\u305f\u3044\u65b9\u306f\u305c\u3072\u3054\u53c2\u52a0\u304f\u3060\u3055\u3044\uff01<\/p>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u3053\u306e1\u518a\u3067\u308f\u304b\u308b\u300c\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u300d\u3092\u914d\u5e03\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5b9f\u9a13\u3067\u306e\u300c\u56f0\u3063\u305f\u300d\u3092\u89e3\u6c7a\u3059\u308b\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9\u3082\u914d\u5e03\u3057\u3066\u3044\u307e\u3059\u3002\u4f75\u305b\u3066\u3054\u3089\u3093\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_qpcr_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u306f\u3058\u3081\u306b \u5f53\u793e\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u306fFast\u30e2\u30fc\u30c9\u3068Standard\u30e2\u30fc\u30c9\u306e2\u7a2e\u985e\u306e\u30e9\u30f3\u30e2\u30fc\u30c9\u304c\u3042\u308a\u307e\u3059\u3002\u71b1\u5909\u6027\u306e\u30b9\u30c6\u30c3\u30d7\u3084\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u30fb\u4f38\u9577\u53cd\u5fdc\u30b9\u30c6\u30c3\u30d7\u306e\u53cd\u5fdc\u6642\u9593\u3068\u6e29\u5ea6\u306e\u4e0a\u3052\u4e0b\u3052\u306e\u30b9\u30d4\u30fc\u30c9\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081F<\/p>\n","protected":false},"author":975,"featured_media":12035,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[28,7],"division":[],"class_list":["post-14608","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-experiment","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f\" \/>\n<meta property=\"og:description\" content=\"\u306f\u3058\u3081\u306b \u5f53\u793e\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u306fFast\u30e2\u30fc\u30c9\u3068Standard\u30e2\u30fc\u30c9\u306e2\u7a2e\u985e\u306e\u30e9\u30f3\u30e2\u30fc\u30c9\u304c\u3042\u308a\u307e\u3059\u3002\u71b1\u5909\u6027\u306e\u30b9\u30c6\u30c3\u30d7\u3084\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u30fb\u4f38\u9577\u53cd\u5fdc\u30b9\u30c6\u30c3\u30d7\u306e\u53cd\u5fdc\u6642\u9593\u3068\u6e29\u5ea6\u306e\u4e0a\u3052\u4e0b\u3052\u306e\u30b9\u30d4\u30fc\u30c9\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081F\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-04T02:21:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-15T07:06:02+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f\",\"datePublished\":\"2023-07-04T02:21:27+00:00\",\"dateModified\":\"2025-04-15T07:06:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/\"},\"wordCount\":185,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic8.jpg\",\"keywords\":[\"\u3084\u3063\u3066\u307f\u305f\",\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic8.jpg\",\"datePublished\":\"2023-07-04T02:21:27+00:00\",\"dateModified\":\"2025-04-15T07:06:02+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic8.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/05\\\/pic8.jpg\",\"width\":1000,\"height\":667},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr_workshop_gsd_ts_3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f","og_description":"\u306f\u3058\u3081\u306b \u5f53\u793e\u306e\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u306b\u306fFast\u30e2\u30fc\u30c9\u3068Standard\u30e2\u30fc\u30c9\u306e2\u7a2e\u985e\u306e\u30e9\u30f3\u30e2\u30fc\u30c9\u304c\u3042\u308a\u307e\u3059\u3002\u71b1\u5909\u6027\u306e\u30b9\u30c6\u30c3\u30d7\u3084\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u30fb\u4f38\u9577\u53cd\u5fdc\u30b9\u30c6\u30c3\u30d7\u306e\u53cd\u5fdc\u6642\u9593\u3068\u6e29\u5ea6\u306e\u4e0a\u3052\u4e0b\u3052\u306e\u30b9\u30d4\u30fc\u30c9\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081F","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-07-04T02:21:27+00:00","article_modified_time":"2025-04-15T07:06:02+00:00","og_image":[{"width":1000,"height":667,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f","datePublished":"2023-07-04T02:21:27+00:00","dateModified":"2025-04-15T07:06:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/"},"wordCount":185,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg","keywords":["\u3084\u3063\u3066\u307f\u305f","\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg","datePublished":"2023-07-04T02:21:27+00:00","dateModified":"2025-04-15T07:06:02+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg","width":1000,"height":667},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr_workshop_gsd_ts_3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3000\u30e9\u30f3\u30e2\u30fc\u30c9\u3067\u7d50\u679c\u306b\u5dee\u304c\u3067\u308b\u304b\u6bd4\u8f03\u3057\u3066\u307f\u305f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"},{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg",760,507,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":539,"filter":"raw","meta":[],"cat_ID":156,"category_count":539,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]},{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/05\/pic8.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14608","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=14608"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14608\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12035"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=14608"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=14608"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=14608"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=14608"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}