{"id":1486,"date":"2018-10-22T00:00:00","date_gmt":"2018-10-21T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/"},"modified":"2023-12-28T14:19:09","modified_gmt":"2023-12-28T05:19:09","slug":"ic_pc","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/","title":{"rendered":"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5"},"content":{"rendered":"<p>\u5e73\u621016\u5e744\u67081\u65e5\u306b\u65bd\u884c\u3055\u308c\u305f\u6c34\u9053\u6cd5\u306e\u6c34\u8cea\u57fa\u6e96\u9805\u76ee\u306b\u81ed\u7d20\u9178\u304c\u8ffd\u52a0\u3055\u308c\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5-\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5\uff08IC-PC\u6cd5\uff09\u304c\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002\u6b21\u3044\u3067\u3001\u5e73\u621029\u5e744\u6708\u306bLC-MS\/MS\u304c\u65b0\u305f\u306b\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002IC-PC\u6cd5\u306f\u591a\u304f\u306e\u6a5f\u95a2\u3067\u3001\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u5206\u6790\u6cd5\u3067\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001IC-PC\u6cd5\u3092\u7528\u3044\u305f\u81ed\u7d20\u9178\u5206\u6790\u306b\u3064\u3044\u3066\u3001\u305d\u306e\u539f\u7406\u3068\u5b9f\u969b\u306e\u6e2c\u5b9a\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>&lt;\u53cd\u5fdc\u539f\u7406&gt;<\/h2>\n<p>\u81ed\u7d20\u9178\u30a4\u30aa\u30f3\u306f\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u6e2c\u5b9a\u3067\u304d\u307e\u3059\u304c\u3001\u8fd1\u508d\u306b\u6eb6\u51fa\u3059\u308b\u5869\u5316\u7269\u30a4\u30aa\u30f3\u3068\u306e\u5206\u96e2\u3001\u6c34\u8cea\u57fa\u6e96\u3067\u6c42\u3081\u3089\u308c\u308b\u57fa\u6e96\u5024\u306e1\/10\u6fc3\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u96e3\u3057\u304f\u3001\u305d\u306e\u6e2c\u5b9a\u306b\u306f\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u8a98\u5c0e\u4f53\u5316\u6cd5\u304c\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n<p>\u81ed\u7d20\u9178\u30a4\u30aa\u30f3\u306f\u3001\u5f37\u9178\u6027\u4e0b\u306b\u3066\u81ed\u7d20\u306e\u4e09\u91cf\u4f53\u3092\u751f\u6210\u3057\u3066\u3001\u4e09\u81ed\u5316\u7269\u30a4\u30aa\u30f3\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u3092268 nm\u306e\u7d2b\u5916\u57df\u6ce2\u9577\u3067\u6e2c\u5b9a\u3057\u307e\u3059\u3002\u53cd\u5fdc\u6db2A\u306b\u4e9c\u785d\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\u6c34\u6eb6\u6db2\u3001\u53cd\u5fdc\u6db2B\u306b\u81ed\u5316\u30ab\u30ea\u30a6\u30e0\uff0f\u786b\u9178\u6df7\u5408\u6c34\u6eb6\u6db2\u3092\u6dfb\u52a0\u3057\u3066\u3001\u30ab\u30e9\u30e0\u6eb6\u51fa\u6db2\u3068\u9806\u6b21\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002\u4e9c\u785d\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\u306f\u4e09\u81ed\u5316\u7269\u304b\u3089\u53ef\u9006\u53cd\u5fdc\u3092\u6291\u5236\u3059\u308b\u305f\u3081\u306b\u6dfb\u52a0\u3055\u308c\u307e\u3059\u3002\u88c5\u7f6e\u69cb\u6210\u3092\u56f31\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<h2>&lt; IC-PC\u6cd5\u306e3\u3064\u306e\u7279\u9577&gt;<\/h2>\n<ul style=\"list-style-type: disc\">\n<li>\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\u3092\u4f75\u7528\u3067\u304d\u308b\u305f\u3081\u3001\u7121\u6a5f\u9670\u30a4\u30aa\u30f3\u306e\u540c\u6642\u6e2c\u5b9a\u3082\u53ef\u80fd<\/li>\n<li>\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u8a98\u5c0e\u4f53\u5316\u306b\u3088\u3063\u3066\u3001\u81ed\u7d20\u9178\u3068\u540c\u6642\u306b\u30e8\u30a6\u7d20\u9178\uff08IO<sub>3<\/sub><sup>&#8211;<\/sup>\uff09\u3001\u4e9c\u5869\u7d20\u9178\uff08ClO<sub>2<\/sub><sup>&#8211;<\/sup>\uff09\u304c\u6e2c\u5b9a\u53ef\u80fd<\/li>\n<li>\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u5f71\u97ff\u3092\u53d7\u3051\u306a\u3044\u305f\u3081\u3001\u81ed\u7d20\u9178\u306e\u9ad8\u611f\u5ea6\u5206\u6790\u304c\u53ef\u80fd<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/f779fc107aa6fe1cbc2147e5dad007c1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4826\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/f779fc107aa6fe1cbc2147e5dad007c1.png\" alt=\"\u88c5\u7f6e\u69cb\u6210\" width=\"579\" height=\"250\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u56f31\uff1a\u88c5\u7f6e\u69cb\u6210<\/p>\n<h2>&lt;\u88c5\u7f6e\u69cb\u6210&gt;<\/h2>\n<p>\u30fb\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5<\/p>\n<p>\u70ad\u9178\u7cfb\u30ab\u30e9\u30e0\u3092\u7528\u3044\u308b\u5834\u5408: \u6eb6\u96e2\u6db2\u9001\u6db2\u30dd\u30f3\u30d7\u3001\u30ab\u30e9\u30e0\u30aa\u30fc\u30d6\u30f3\u3001\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\u304c\u5fc5\u8981<\/p>\n<p>\u6c34\u9178\u5316\u7269\u7cfb\u30ab\u30e9\u30e0\u3092\u7528\u3044\u308b\u5834\u5408: \u4e0a\u8a18\u306b\u52a0\u3048\u3001\u6eb6\u96e2\u6db2\u30b8\u30a7\u30cd\u30ec\u30fc\u30bf\u30fc\u304c\u5fc5\u8981<\/p>\n<p>\u30fb\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u30b7\u30b9\u30c6\u30e0<\/p>\n<p>PCM-520\uff08\u53cd\u5fdc\u6db2\u9001\u6db2\u30dd\u30f3\u30d7\u3001\u30d2\u30fc\u30bf\u30fc\u4ed8\u53cd\u5fdc\u30b3\u30a4\u30eb\u3001UV\/Vis\u691c\u51fa\u5668\u3001\u30ea\u30b6\u30fc\u30d0\u30fc\u30e6\u30cb\u30c3\u30c8\uff09<\/p>\n<p>\u30fb\u30c7\u30fc\u30bf\u51e6\u7406\u30b7\u30b9\u30c6\u30e0<\/p>\n<h2>&lt;\u70ad\u9178\u7cfb\u30ab\u30e9\u30e0\u306b\u3088\u308b\u6e2c\u5b9a\u6761\u4ef6&gt;<\/h2>\n<ul>\n<li>\u88c5\u7f6e: \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3001PCM-520\u30b7\u30b9\u30c6\u30e0<\/li>\n<li>\u30ab\u30e9\u30e0: \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Thero Scientific\u2122 Dionex\u2122 IonPac\u2122 AS9-HC \/ AG9-HC<\/li>\n<li>\u30ab\u30e9\u30e0\u6e29\u5ea6\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 35\u2103<\/li>\n<li>\u6eb6\u96e2\u6db2\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 9.0 mmol\/L Na<sub>2<\/sub>CO<sub>3<\/sub><\/li>\n<li>\u6eb6\u96e2\u6db2\u6d41\u91cf \uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1.0 mL\/min<\/li>\n<li>\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Thermo Scientific Dionex ACRS 500<\/li>\n<li>\u518d\u751f\u6db2\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 12.5 mmol\/L H<sub>2<\/sub>SO<sub>4<\/sub><\/li>\n<li>\u518d\u751f\u6db2\u6d41\u91cf\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1.0 mL\/min<\/li>\n<li>\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u53cd\u5fdc\u6db2\uff1a\u00a0\u00a0\u00a0\u00a0 A\uff09 1.2 mmol\/L NaNO<sub>2<\/sub> \u3000B\uff091.5 mol\/L KBr\uff0f1.0 mol\/L H<sub>2<\/sub>SO<sub>4<\/sub><\/li>\n<li>\u53cd\u5fdc\u6db2\u6d41\u91cf\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 A\uff09 0.2 mL\/min\u3000 B\uff09 0.4 mL\/min<\/li>\n<li>\u53cd\u5fdc\u30b3\u30a4\u30eb\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 2.0 m \u00d7 0.51 mm I.D.<\/li>\n<li>\u53cd\u5fdc\u30b3\u30a4\u30eb\u6e29\u5ea6\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 40\u2103<\/li>\n<li>\u8a66\u6599\u6ce8\u5165\u91cf\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 100 \u03bcL<\/li>\n<li>\u691c\u51fa\u5668\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u96fb\u6c17\u4f1d\u5c0e\u5ea6\u3001UV\/Vis\uff08\u03bb=268 nm\uff09<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2>&lt;\u6c34\u9178\u5316\u7269\u7cfb\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u6e2c\u5b9a\u6761\u4ef6&gt;<\/h2>\n<ul>\n<li>\u88c5\u7f6e\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3001PCM<\/li>\n<li>\u30ab\u30e9\u30e0\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Dionex IonPac AG18\/ AS18<\/li>\n<li>\u30ab\u30e9\u30e0\u6e29\u5ea6\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 45\u2103<\/li>\n<li>\u6eb6\u96e2\u6db2 \uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 15\uff5e50 mmol\/L KOH\uff08\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\uff09<\/li>\n<li>\u6d41\u91cf\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1.0 mL\/min<\/li>\n<li>\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc \uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 Thermo Scientific Dionex DRS 500<\/li>\n<li>\u518d\u751f\u6db2\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u8d85\u7d14\u6c34<\/li>\n<li>\u518d\u751f\u6db2\u6d41\u91cf\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 2.0 mL\/min<\/li>\n<li>\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u53cd\u5fdc\u6db2\uff1a\u00a0\u00a0\u00a0\u00a0 A\uff09 1.2 mmol\/L NaNO<sub>2<\/sub><sub>\u3000<\/sub> B\uff091.5 mol\/L KBr\/1.0 mol\/L H<sub>2<\/sub>SO<sub>4<\/sub><\/li>\n<li>\u53cd\u5fdc\u6db2\u6d41\u91cf\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 A\uff09 0.2 mL\/min B\uff09 0.4 mL\/min<\/li>\n<li>\u53cd\u5fdc\u30b3\u30a4\u30eb \uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 2.0 m \u00d7 0.51 mm I.D.<\/li>\n<li>\u53cd\u5fdc\u30b3\u30a4\u30eb\u6e29\u5ea6\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 40\u2103<\/li>\n<li>\u8a66\u6599\u6ce8\u5165\u91cf\uff1a \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 200 \u03bcL<\/li>\n<li>\u691c\u51fa\u5668\uff1a\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u96fb\u6c17\u4f1d\u5c0e\u5ea6\u3001UV\/Vis \uff08\u03bb=268 nm\uff09<\/li>\n<\/ul>\n<h2>&lt;\u6e2c\u5b9a\u7d50\u679c&gt;<\/h2>\n<p>\u4ee5\u4e0b\u306b\u70ad\u9178\u7cfb\u30ab\u30e9\u30e0Dionex IonPac AS9-HC\u3092\u7528\u3044\u305f\u5834\u5408\u306e\u30e8\u30a6\u7d20\u9178\u3001\u4e9c\u5869\u7d20\u9178\u3001\u81ed\u7d20\u9178\u6a19\u6e96\u54041 \u03bcg\/L\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u6761\u4ef6\u306b\u304a\u3051\u308b\u81ed\u7d20\u9178\u306e\u76f4\u7dda\u6027\u306f0.5\uff5e50 \u03bcg\/L\u306e\u7bc4\u56f2\u3067\u3001\u76f8\u95a2\u4fc2\u65700.999\u4ee5\u4e0a\u3001\u8a66\u6599\u6ce8\u5165\u91cf100 \u03bcL\u306e\u3068\u304d\u306e\u691c\u51fa\u4e0b\u9650\uff08S\/N=3\uff09\u306f0.58 \u03bcg\/L \u3067\u3057\u305f\u3002\u307e\u305f\u30011.0 \u03bcg\/L\u306e\u81ed\u7d20\u9178\u3092\u7528\u3044\u305f\u3068\u304d\u306e\u7e70\u308a\u8fd4\u3057\u518d\u73fe\u6027\uff08\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\u3001n=5\uff09\u306f\u30013.5 %\u3067\u3057\u305f\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/86467d97bbea9be9aabadc92304acbb2.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4832\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/86467d97bbea9be9aabadc92304acbb2.png\" alt=\"Dionex IonPac AS9-HC\u3092\u7528\u3044\u305f\u5834\u5408\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\" width=\"592\" height=\"409\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u56f32\uff1aDionex IonPac AS9-HC\u3092\u7528\u3044\u305f\u5834\u5408\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/p>\n<p>\u6b21\u306b\u6c34\u9178\u5316\u7269\u7cfb\u30ab\u30e9\u30e0Dionex IonPac AS18\u3092\u7528\u3044\u305f\u5834\u5408\u306e\u81ed\u7d20\u91781\u3000\u03bcg\/L \u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u6761\u4ef6\u306b\u304a\u3051\u308b\u81ed\u7d20\u9178\u306e\u76f4\u7dda\u6027\u306f\u30010.5\uff5e50 \u03bcg\/L \u306e\u7bc4\u56f2\u3067\u3001\u76f8\u95a2\u4fc2\u65700.999 \u4ee5\u4e0a\u3001\u8a66\u6599\u5c0e\u5165\u91cf200 \u03bcL \u306e\u3068\u304d\u306e\u691c\u51fa\u4e0b\u9650\uff08S\/N=3\uff09\u306f0.30 \u03bcg\/L \u3067\u3057\u305f\u3002<\/p>\n<p>\u307e\u305f\u30011.0 \u03bcg\/L\u306e\u81ed\u7d20\u9178\u306e\u7e70\u308a\u8fd4\u3057\u518d\u73fe\u6027\uff08\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\u3001n=5\uff09\u306f2.9 %\u3067\u3057\u305f\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/db90d9f6c59b07cc3b8263c90ce4c5c5.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4833\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/db90d9f6c59b07cc3b8263c90ce4c5c5.png\" alt=\"Dionex IonPac AS18\u3092\u7528\u3044\u305f\u5834\u5408\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\" width=\"614\" height=\"402\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u56f33\uff1aDionex IonPac AS18\u3092\u7528\u3044\u305f\u5834\u5408\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/p>\n<p>&nbsp;<\/p>\n<p>\u6b21\u306b\u3001\u6c34\u9053\u6c34\u4e2d\u306e\u81ed\u7d20\u9178\u306bDionex IonPac AS9-HC \u3092\u7528\u3044\u305f\u969b\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u3001<\/p>\n<p>\u540c\u3058\u8a66\u6599\u3092Dionex IonPac AS18 \u3092\u4f7f\u7528\u3057\u3066\u6e2c\u5b9a\u3057\u305f\u7d50\u679c\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/37280cedc28f316a6f4a991f00b703dc.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4830\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/37280cedc28f316a6f4a991f00b703dc.png\" alt=\"Dionex IonPac AS9-HC \u3092\u7528\u3044\u305f\u6c34\u9053\u6c34\u4e2d\u306e\u6e2c\u5b9a\u4f8b\" width=\"409\" height=\"477\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u56f34\uff1aDionex IonPac AS9-HC \u3092\u7528\u3044\u305f\u6c34\u9053\u6c34\u4e2d\u306e\u6e2c\u5b9a\u4f8b<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/317cda513b3f3dbf10387923a12e54c8.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-4831\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/317cda513b3f3dbf10387923a12e54c8.png\" alt=\"Dionex IonPac AS18 \u3092\u7528\u3044\u305f\u6c34\u9053\u6c34\u306e\u6e2c\u5b9a\u4f8b\" width=\"404\" height=\"451\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u56f35\uff1aDionex IonPac AS18 \u3092\u7528\u3044\u305f\u6c34\u9053\u6c34\u306e\u6e2c\u5b9a\u4f8b<\/p>\n<p>&nbsp;<\/p>\n<h2>&lt;\u4f7f\u7528\u3059\u308b\u8a66\u85ac\u3068\u8abf\u88fd\u65b9\u6cd5&gt;<\/h2>\n<p>IC-PC\u6cd5\u306b\u3088\u308b\u81ed\u7d20\u9178\u6e2c\u5b9a\u306e\u969b\u306b\u7528\u3044\u308b\u8a66\u85ac\u3068\u5404\u6eb6\u6db2\u306e\u8abf\u88fd\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002<\/p>\n<h4>\u4f7f\u7528\u3059\u308b\u8a66\u85ac<\/h4>\n<ul>\n<li>\u6eb6\u96e2\u6db2\u7528\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u70ad\u9178\u30ca\u30c8\u30ea\u30a6\u30e0 \u7279\u7d1a\u7c89\u672b<\/li>\n<li>\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0 \u7279\u7d1a\u7c89\u672b<\/li>\n<li>\u518d\u751f\u6db2\u7528\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 1 mol\/L \u786b\u9178 \u5bb9\u91cf\u5206\u6790\u7528<\/li>\n<li>\u53cd\u5fdc\u6db2\u7528\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u81ed\u5316\u30ab\u30ea\u30a6\u30e0 \u7279\u7d1a\u7c89\u672b<\/li>\n<li>\u6fc3\u786b\u9178 \u7cbe\u5bc6\u5206\u6790\u7528<\/li>\n<li>\u4e9c\u785d\u9178\u30ca\u30c8\u30ea\u30a6\u30e0 \u7279\u7d1a\u7c89\u672b<\/li>\n<li>\u6a19\u6e96\u7528\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0 \u81ed\u7d20\u9178\u30ab\u30ea\u30a6\u30e0 \u7279\u7d1a\u7c89\u672b<\/li>\n<li>\u4e9c\u5869\u7d20\u9178\u30ab\u30ea\u30a6\u30e0 \u7279\u7d1a\u7c89\u672b<\/li>\n<li>\u30e8\u30a6\u7d20\u9178\u30ab\u30ea\u30a6\u30e0 \u7279\u7d1a\u7c89\u672b<\/li>\n<\/ul>\n<h4>&lt;\u5404\u6eb6\u6db2\u306e\u8abf\u88fd\u65b9\u6cd5&gt;<\/h4>\n<h6>\u2460\u6eb6\u96e2\u6db2<\/h6>\n<p><u>1) Dionex IonPac \u00a0AS9-HC <\/u><u>\u306e\u5834\u5408\uff08<\/u><u>9.0 mmol\/L Na<sub>2<\/sub>CO<sub>3<\/sub><\/u><u>\uff09<\/u><\/p>\n<p>\u6eb6\u96e2\u6db2\u539f\u6db2\uff080.9 mol\/L Na<sub>2<\/sub>CO<sub>3<\/sub>\uff09\u306f\u3001Na<sub>2<\/sub>CO<sub>3<\/sub> \u309247.7 g\u79e4\u91cf\u3057\u3001\u7d14\u6c34\u3067\u5168\u91cf\u3092500 mL \u3068\u3057\u307e\u3059\u3002\u4f7f\u7528\u6642\u306b\u539f\u6db2\u3092\u8131\u6c17\u3057\u305f\u7d14\u6c34\u3067100 \u500d\u306b\u5e0c\u91c8\u3057\u307e\u3059\u3002<\/p>\n<p><u>2) Dionex IonPac\u00a0 AS18 <\/u><u>\u306e\u5834\u5408\uff08<\/u><u>15<\/u><u>\uff5e<\/u><u>50 mmol\/L KOH<\/u><u>\uff09<\/u><\/p>\n<p>\u6eb6\u96e2\u6db2\u30b8\u30a7\u30cd\u30ec\u30fc\u30bf\u30fc\u306b\u3088\u308a\u81ea\u52d5\u751f\u6210\u3055\u305b\u307e\u3059\u3002<\/p>\n<h6>\u2461\u518d\u751f\u6db2\uff0812.5 mmol\/L H<sub>2<\/sub>SO<sub>4<\/sub>\uff09<\/h6>\n<p>1 mol\/L \u786b\u9178\u309250 mL \u91cf\u308a\u3001\u7d14\u6c34\u3067\u5168\u91cf\u30924 L\u306b\u3057\u307e\u3059\u3002\uff08\u9670\u30a4\u30aa\u30f3\u3068\u306e\u540c\u6642\u5206\u6790\u3092\u884c\u308f\u306a\u3044\u5834\u5408\u306f\u3001\u518d\u751f\u6db2\u306f\u4e0d\u8981\u3067\u3059\u3002\uff09<\/p>\n<p>&nbsp;<\/p>\n<h6>\u2462\u53cd\u5fdc\u6db2A\uff081.2 mmol\/L NaNO<sub>2<\/sub>\uff09<\/h6>\n<p>4.14 g \u306e\u4e9c\u785d\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\u3092\u8131\u6c17\u3057\u305f\u7d14\u6c34500 mL\u306b\u6eb6\u304b\u3057\u3001\u539f\u6db2\u3068\u3057\u307e\u3059\u3002\u51b7\u6697\u6240\u3067\u4fdd\u7ba1\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4f7f\u7528\u6642\u306b\u539f\u6db2\u3092100\u500d\u306b\u5e0c\u91c8\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h6>\u2463\u53cd\u5fdc\u6db2B\uff081.5 mol\/L KBr\u3001 1.0 mol\/L H<sub>2<\/sub>SO<sub>4<\/sub>\uff09<\/h6>\n<p>500 mL\u306e\u30e1\u30b9\u30d5\u30e9\u30b9\u30b3\u306b\u7d04300 mL\u306e\u8131\u6c17\u3057\u305f\u7d14\u6c34\u3092\u5165\u308c\u300189.4 g\u306e\u81ed\u5316\u30ab\u30ea\u30a6\u30e0\u3092\u6eb6\u304b\u3057\u307e\u3059\u3002\u5b8c\u5168\u306b\u6eb6\u3051\u3066\u304b\u3089\u30c9\u30e9\u30d5\u30c8\u5185\u3067\u6fc3\u786b\u917826.6 mL \u3092\u9759\u304b\u306b\u52a0\u3048\u307e\u3059\u3002\u6fc3\u786b\u9178\u3092\u52a0\u3048\u308b\u969b\u306f\u3001\u71b1\u304a\u3088\u3073\u7159\u304c\u767a\u751f\u3059\u308b\u305f\u3081\u3001\u4fdd\u8b77\u5177\u3092\u3064\u3051\u308b\u306a\u3069\u5341\u5206\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3055\u3089\u306b\u3001\u3086\u3063\u304f\u308a\u3068\u8d85\u7d14\u6c34\u3092\u52a0\u3048\u3066\u30e1\u30b9\u30a2\u30c3\u30d7\u3057\u307e\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h6>\u2464\u6a19\u6e96\uff08\u54041000 mg\/L\uff09<\/h6>\n<p>\u81ed\u7d20\u9178\uff1a\u81ed\u7d20\u9178\u30ab\u30ea\u30a6\u30e00.130 g\u3092\u7d14\u6c34\u306b\u6eb6\u304b\u3057\u3001\u5168\u91cf\u3092100 mL\u3068\u3057\u307e\u3059\u3002<\/p>\n<p>\u30e8\u30a6\u7d20\u9178\uff1a\u30e8\u30a6\u7d20\u9178\u30ab\u30ea\u30a6\u30e00.122 g \u3092\u7d14\u6c34\u306b\u6eb6\u304b\u3057\u3001\u5168\u91cf\u3092100 mL\u3068\u3057\u307e\u3059\u3002<\/p>\n<p>\u4e9c\u5869\u7d20\u9178\uff1a\u4e9c\u5869\u7d20\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\uff08\u542b\u91cf80 %\uff090.167 g\u3092\u7d14\u6c34\u306b\u6eb6\u304b\u3057\u3001\u5168\u91cf\u3092100 mL\u3068\u3057\u307e\u3059\u3002<\/p>\n<p>\u4f7f\u7528\u6642\u306f\u3053\u308c\u3089\u306e1000 mg\/L\u6eb6\u6db2\u3092\u7d14\u6c34\u3067\u5e0c\u671b\u6fc3\u5ea6\u306b\u5e0c\u91c8\u3057\u3066\u304f\u3060\u3055\u3044\u3002\uff08\u4f4e\u6fc3\u5ea6\u306e\u4e9c\u5869\u7d20\u9178\u306f\u975e\u5e38\u306b\u4e0d\u5b89\u5b9a\u306a\u305f\u3081\u3001\u6570\u6642\u9593\u3067\u30d4\u30fc\u30af\u3068\u3057\u3066\u691c\u51fa\u3067\u304d\u306a\u304f\u306a\u308a\u307e\u3059\u306e\u3067\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\uff09<\/p>\n<p>&nbsp;<\/p>\n<h2>&lt;\u307e\u3068\u3081&gt;<\/h2>\n<p>IC-PC\u6cd5\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u6c34\u8cea\u57fa\u6e96\u5024\u306e1\/10\uff081 \u03bcg\/L\uff09\u306b\u304a\u3044\u3066\u3001\u81ed\u7d20\u9178\u304c\u7cbe\u5ea6\u826f\u304f\u6e2c\u5b9a\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u3055\u3089\u306b\u3001\u30b5\u30d7\u30ec\u30c3\u30b5\u30fc\u3092\u7528\u3044\u3066\u96fb\u6c17\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\u3092\u4f75\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u9670\u30a4\u30aa\u30f3\u6210\u5206\u306e\u540c\u6642\u6e2c\u5b9a\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u6700\u8fd1\u3067\u306f\u81ed\u7d20\u9178\u306e\u5206\u6790\u306e\u305f\u3081\u306bIC-MS\/MS\u306e\u958b\u767a\u3082\u9032\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002IC-MS\/MS\u3067\u306f\u9762\u5012\u306a\u53cd\u5fdc\u8a66\u85ac\u306e\u4f5c\u6210\u3084\u524d\u51e6\u7406\u304c\u4e0d\u8981\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u8a73\u7d30\u306f\u4ee5\u4e0b\u306e\u300c\u6c34\u9053\u6c34\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u306e\u5206\u6790\u300d\u3067\u3082\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u3010\u5206\u6790\u4e8b\u4f8b\u3011\u6c34\u9053\u6c34\u4e2d\u306e\u9670\u30a4\u30aa\u30f3\u306e\u5206\u6790<\/h2>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/analysis-of-anions-in-tap-water.html?ICID=cmd_ic_r04_jp_ic_pc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u304a\u5f79\u7acb\u3061\u8cc7\u6599\uff08\u57fa\u790e\u7de8\uff09<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u3092\u4f7f\u3044\u59cb\u3081\u3088\u3046\u3068\u8003\u3048\u3066\u3044\u308b\u3001\u5206\u96e2\u306e\u539f\u7406\u3084\u5206\u6790\u6642\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u898b\u76f4\u3057\u305f\u3044\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306e\u6a5f\u80fd\u3092\u4f7f\u3044\u3053\u306a\u3057\u305f\u3044\u3001\u5177\u4f53\u7684\u306a\u5206\u6790\u4e8b\u4f8b\u3092\u77e5\u308a\u305f\u3044\u306a\u3069\u3002\u696d\u52d9\u306b\u3059\u3050\u306b\u5f79\u7acb\u3064\u30ce\u30a6\u30cf\u30a6\u304c\u8a70\u307e\u3063\u305f\u8cc7\u6599\u3092\u305c\u3072\u3001\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/ion-chromatography-ic\/dl-doc-basic.html?ICID=cmd_ic_r04_jp_ic_pc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>\u3010\u7121\u6599\u3011 e-learning \u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u57fa\u790e\u77e5\u8b58<\/h2>\n<p>\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3064\u3044\u3066\u3001\u3088\u308a\u6df1\u304f\u5b66\u3073\u305f\u3044\u65b9\u306f\u3001e-learning(\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc)\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u5206\u96e2\u3084\u691c\u51fa\u6cd5\u306a\u3069\u306e\u539f\u7406\u3092\u4e2d\u5fc3\u3068\u3057\u305f\u57fa\u790e\u306e\u89e3\u8aac\u3084\u3001\u5b9f\u969b\u306e\u5206\u6790\u6642\u306b\u6ce8\u610f\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u307e\u3067\u3001\u696d\u52d9\u306b\u5f79\u7acb\u3064\u30d2\u30f3\u30c8\u304c\u5b66\u3079\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/e-learnings\/ic-dl.html?ICID=cmd_ic_r04_jp_ic_pc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u8996\u8074\u306e\u304a\u7533\u3057\u8fbc\u307f\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5e73\u621016\u5e744\u67081\u65e5\u306b\u65bd\u884c\u3055\u308c\u305f\u6c34\u9053\u6cd5\u306e\u6c34\u8cea\u57fa\u6e96\u9805\u76ee\u306b\u81ed\u7d20\u9178\u304c\u8ffd\u52a0\u3055\u308c\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5-\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5\uff08IC-PC\u6cd5\uff09\u304c\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002\u6b21\u3044\u3067\u3001\u5e73\u621029\u5e744\u6708\u306bLC-MS\/MS\u304c\u65b0\u305f\u306b\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002IC-PC\u6cd5<\/p>\n","protected":false},"author":988,"featured_media":4995,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[135],"division":[],"class_list":["post-1486","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-ic-pc","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u5e73\u621016\u5e744\u67081\u65e5\u306b\u65bd\u884c\u3055\u308c\u305f\u6c34\u9053\u6cd5\u306e\u6c34\u8cea\u57fa\u6e96\u9805\u76ee\u306b\u81ed\u7d20\u9178\u304c\u8ffd\u52a0\u3055\u308c\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5-\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5\uff08IC-PC\u6cd5\uff09\u304c\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002\u6b21\u3044\u3067\u3001\u5e73\u621029\u5e744\u6708\u306bLC-MS\/MS\u304c\u65b0\u305f\u306b\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002IC-PC\u6cd5\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2018-10-21T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-12-28T05:19:09+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5\",\"datePublished\":\"2018-10-21T15:00:00+00:00\",\"dateModified\":\"2023-12-28T05:19:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/\"},\"wordCount\":294,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1_16116127_4c-RESIZED.png\",\"keywords\":[\"IC-PC\u6cd5\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/\",\"name\":\"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1_16116127_4c-RESIZED.png\",\"datePublished\":\"2018-10-21T15:00:00+00:00\",\"dateModified\":\"2023-12-28T05:19:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1_16116127_4c-RESIZED.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1_16116127_4c-RESIZED.png\",\"width\":1200,\"height\":630,\"caption\":\"\u81ed\u7d20\u9178\u5206\u6790\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ic_pc\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/","og_locale":"ja_JP","og_type":"article","og_title":"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5","og_description":"\u5e73\u621016\u5e744\u67081\u65e5\u306b\u65bd\u884c\u3055\u308c\u305f\u6c34\u9053\u6cd5\u306e\u6c34\u8cea\u57fa\u6e96\u9805\u76ee\u306b\u81ed\u7d20\u9178\u304c\u8ffd\u52a0\u3055\u308c\u3001\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5-\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5\uff08IC-PC\u6cd5\uff09\u304c\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002\u6b21\u3044\u3067\u3001\u5e73\u621029\u5e744\u6708\u306bLC-MS\/MS\u304c\u65b0\u305f\u306b\u63a1\u7528\u3055\u308c\u307e\u3057\u305f\u3002IC-PC\u6cd5","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2018-10-21T15:00:00+00:00","article_modified_time":"2023-12-28T05:19:09+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED.png","type":"image\/png"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5","datePublished":"2018-10-21T15:00:00+00:00","dateModified":"2023-12-28T05:19:09+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/"},"wordCount":294,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED.png","keywords":["IC-PC\u6cd5"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/","name":"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED.png","datePublished":"2018-10-21T15:00:00+00:00","dateModified":"2023-12-28T05:19:09+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED.png","width":1200,"height":630,"caption":"\u81ed\u7d20\u9178\u5206\u6790"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ic_pc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u81ed\u7d20\u9178\u5206\u6790\u306b\u304a\u30b9\u30b9\u30e1\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2010\u30dd\u30b9\u30c8\u30ab\u30e9\u30e0\u5206\u6790\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":135,"label":"IC-PC\u6cd5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED-1024x538.png",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":135,"name":"IC-PC\u6cd5","slug":"ic-pc","term_group":0,"term_taxonomy_id":135,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":1486,"position":0},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":1486,"position":1},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":1486,"position":2},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":1486,"position":3},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":1486,"position":4},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":1486,"position":5},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1_16116127_4c-RESIZED.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1486","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1486"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1486\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/4995"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1486"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1486"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1486"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1486"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}