{"id":14862,"date":"2023-07-27T16:50:06","date_gmt":"2023-07-27T07:50:06","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=14862"},"modified":"2025-03-06T17:31:43","modified_gmt":"2025-03-06T08:31:43","slug":"rna_workshop_bid_ts_5","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f"},"content":{"rendered":"<p>RNA\u62bd\u51fa\u306b\u306f\u5bfe\u8c61\u30b5\u30f3\u30d7\u30eb\u306b\u5408\u308f\u305b\u3066\u3055\u307e\u3056\u307e\u306a\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u4e2d\u3067\u3082\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u30bf\u30a4\u30d7\u306e\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u7cbe\u88fd\u65b9\u6cd5\u306f\u8ab0\u3067\u3082\u7c21\u5358\u306b\u77ed\u6642\u9593\u3067RNA\u3092\u56de\u53ce\u3067\u304d\u308b\u65b9\u6cd5\u306e1\u3064\u3067\u3059\u3002<\/p>\n<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3067RNA\u62bd\u51fa\u3059\u308b\u30ad\u30c3\u30c8\u306f\u5f53\u793e\u3060\u3051\u3067\u306a\u304f\u3001\u3055\u307e\u3056\u307e\u306a\u30e1\u30fc\u30ab\u30fc\u304b\u3089\u8ca9\u58f2\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u57fa\u672c\u7684\u306a\u539f\u7406\u306f\u307b\u3068\u3093\u3069\u4e00\u7dd2\u306e\u306f\u305a\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u5f53\u793e\u306eInvitrogen\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/dna-rna-purification-analysis\/rna-extraction\/rna-types\/total-rna-extraction\/purelink-rna-mini-kit.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">PureLink\u2122 RNA Mini \u30ad\u30c3\u30c8<\/a>\uff08\u88fd\u54c1\u756a\u53f712183020\uff09\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<br \/>\n\u672c\u30ad\u30c3\u30c8\u304c\u304a\u624b\u5143\u306b\u5c4a\u3044\u305f\u5f8c\u3001\u6700\u521d\u306b\u5b9f\u65bd\u3057\u3066\u3044\u305f\u3060\u304f\u64cd\u4f5c\u306fWash Buffer II\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u898f\u5b9a\u91cf\u52a0\u3048\u3066\u3044\u305f\u3060\u304f\u3053\u3068\u3067\u3059\u30024 mL\u306eWash Buffer II\u306b\u5bfe\u3057\u3066\u300116 mL\u306e96\uff5e100%\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u3066\u6df7\u5408\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\uff08\u7d42\u6fc3\u5ea680\u5bb9\u91cf%\uff09\u3002\u8a66\u85ac\u306e\u30dc\u30c8\u30eb\u306b\u3082\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u305f\u3053\u3068\u3092\u8a18\u9332\u3059\u308b\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u306f\u3042\u308b\u306e\u3067\u3059\u304c\u3001\u4f7f\u7528\u9014\u4e2d\u3067\u6db2\u91cf\u304c\u6e1b\u3063\u3066\u304f\u308b\u3068\u672c\u5f53\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u5165\u308c\u305f\u306e\u304b\u4e0d\u5b89\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3067\u306f\u3001\u3046\u3063\u304b\u308a\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u5fd8\u308c\u305f\u307e\u307e\u5b9f\u9a13\u3059\u308b\u3068\u3069\u3046\u306a\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<h2>\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n<p>\u307e\u305a\u306fRNA\u62bd\u51fa\u306e\u7d50\u679c\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-14865\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/29d3bc99193cb0b837fb8cc53f050ae5-2.png\" alt=\"\" width=\"2649\" height=\"626\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/29d3bc99193cb0b837fb8cc53f050ae5-2.png 2649w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/29d3bc99193cb0b837fb8cc53f050ae5-2-300x71.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/29d3bc99193cb0b837fb8cc53f050ae5-2-1024x242.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/29d3bc99193cb0b837fb8cc53f050ae5-2-768x181.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/29d3bc99193cb0b837fb8cc53f050ae5-2-1536x363.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/29d3bc99193cb0b837fb8cc53f050ae5-2-2048x484.png 2048w\" sizes=\"auto, (max-width: 2649px) 100vw, 2649px\" \/><br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-14867\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/cbf5b9f60da99bf791c0aa12a770f429-2.png\" alt=\"\" width=\"3386\" height=\"903\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/cbf5b9f60da99bf791c0aa12a770f429-2.png 3386w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/cbf5b9f60da99bf791c0aa12a770f429-2-300x80.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/cbf5b9f60da99bf791c0aa12a770f429-2-1024x273.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/cbf5b9f60da99bf791c0aa12a770f429-2-768x205.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/cbf5b9f60da99bf791c0aa12a770f429-2-1536x410.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/cbf5b9f60da99bf791c0aa12a770f429-2-2048x546.png 2048w\" sizes=\"auto, (max-width: 3386px) 100vw, 3386px\" \/><\/p>\n<p>\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u306a\u3057\u306eWash Buffer II\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001RNA\u3092\u307b\u3068\u3093\u3069\u56de\u53ce\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3064\u307e\u308a\u3001Lysis Buffer\u3067\u6eb6\u89e3\u3001\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u3078\u306e\u30a2\u30d7\u30e9\u30a4\u3001Wash Buffer I\u30671\u56de\u6d17\u6d44\u3001Wash Buffer II\u30672\u56de\u6d17\u6d44\u3001RNase-Free Water\u3067\u6eb6\u51fa\u3001\u3068\u3044\u3046\u624b\u9806\u306f\u5171\u901a\u3060\u3063\u305f\u306e\u306b\u3001Wash Buffer II\u3078\u306e\u30a8\u30bf\u30ce\u30fc\u30eb\u6dfb\u52a0\u306e\u6709\u7121\u306e\u307f\u3067RNA\u304c\u56de\u53ce\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n<p>\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u5fd8\u308c\u308b\u3068\u3001\u306a\u305cRNA\u62bd\u51fa\u306b\u5931\u6557\u3057\u3066\u3057\u307e\u3046\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u307e\u305a\u306f\u3001\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u7528\u3044\u305fRNA\u62bd\u51fa\u306e\u539f\u7406\u304b\u3089\u8003\u3048\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u901a\u5e38\u306e\u6c34\u3084Buffer\u306a\u3069\u306b\u6eb6\u3051\u3066\u3044\u308bRNA\u306f\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u7d50\u5408\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u9ad8\u6fc3\u5ea6\u306e\u30ab\u30aa\u30c8\u30ed\u30d4\u30c3\u30af\u5869\uff08\u30b0\u30a2\u30cb\u30b8\u30f3\u30a4\u30bd\u30c1\u30aa\u30b7\u30a2\u30cd\u30fc\u30c8\uff09\u3084\u30a8\u30bf\u30ce\u30fc\u30eb\u306e\u5b58\u5728\u4e0b\u3067\u306f\u3001RNA\u304b\u3089\u6c34\u5206\u5b50\u304c\u596a\u308f\u308c\u308b\u3053\u3068\u3067\u758e\u6c34\u6027\u304c\u9ad8\u307e\u308aRNA\u304c\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u7d50\u5408\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<br \/>\n\u6b21\u306b\u3001\u305d\u308c\u305e\u308c\u306eBuffer\u306e\u9055\u3044\u3092\u8003\u3048\u3066\u307f\u307e\u3057\u3087\u3046\u3002Lysis Buffer\u3084Wash Buffer I\u306f\u30ab\u30aa\u30c8\u30ed\u30d4\u30c3\u30af\u5869\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001Wash Buffer II\u306b\u306f\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u6eb6\u89e3\u5f8c\u306e\u30ab\u30e9\u30e0\u3078\u306e\u30a2\u30d7\u30e9\u30a4\u6642\u3084Wash\u6642\u306b\u306fRNA\u306e\u758e\u6c34\u6027\u304c\u7dad\u6301\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u306b\u3001RNA\u304c\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u7d50\u5408\u3067\u304d\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u80cc\u666f\u304b\u3089\u3001Wash Buffer II\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u3046\u3063\u304b\u308a\u52a0\u3048\u5fd8\u308c\u308b\u3068RNA\u306e\u758e\u6c34\u6027\u304c\u5931\u308f\u308c\u3066\u3057\u307e\u3044\u3001\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u7d50\u5408\u3067\u304d\u305a\u3001\u30d5\u30ed\u30fc\u30b9\u30eb\u30fc\u306b\u6d41\u308c\u3066\u3057\u307e\u3063\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u305d\u3093\u306a\u3053\u3068\u306a\u3089\u3001\u5546\u54c1\u306b\u306f\u3058\u3081\u304b\u3089\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u3066\u304a\u3044\u3066\u304f\u308c\u308c\u3070\u826f\u3044\u306e\u306b\u3001\u3068\u3044\u3046\u304a\u58f0\u304c\u805e\u3053\u3048\u3066\u304d\u305d\u3046\u3067\u3059\u3002\u6700\u521d\u306b\u3054\u8aac\u660e\u3057\u305f\u3088\u3046\u306b\u3001Wash Buffer II\u306f\u30a8\u30bf\u30ce\u30fc\u30eb\u306e\u7d42\u6fc3\u5ea680\u5bb9\u91cf%\u3067\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u6fc3\u5ea6\u304c\u7d0467\u5bb9\u91cf%\u4ee5\u4e0a\u306b\u306a\u308b\u3068\u3001\u6d88\u9632\u6cd5\u3067\u5b9a\u3081\u308b\u5371\u967a\u7269\u3068\u306a\u3063\u3066\u3057\u307e\u3044\u8f38\u9001\u6642\u306b\u3055\u307e\u3056\u307e\u306a\u6ce8\u610f\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u304a\u624b\u6570\u3092\u304a\u639b\u3051\u3057\u307e\u3059\u304c\u3001\u30ad\u30c3\u30c8\u3092\u304a\u5c4a\u3051\u3057\u305f\u5f8c\u3001\u304a\u5ba2\u3055\u307e\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u6dfb\u52a0\u3092\u304a\u9858\u3044\u3057\u3066\u3044\u308b\u6b21\u7b2c\u3067\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/dna-rna-purification-analysis\/rna-extraction\/rna-types\/total-rna-extraction\/purelink-rna-mini-kit.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">PureLink RNA Mini \u30ad\u30c3\u30c8<\/a>\u306eWash Buffer II\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u3046\u3063\u304b\u308a\u6dfb\u52a0\u3057\u5fd8\u308c\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306e\u7d50\u679c\u3092\u304a\u793a\u3057\u3057\u307e\u3057\u305f\u3002\u30ad\u30c3\u30c8\u3092\u958b\u68b1\u3057\u305f\u65b9\u306f\u3001Wash Buffer II\u306e\u30dc\u30c8\u30eb\u306b\u898f\u5b9a\u91cf\u306e\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u3001\u30dc\u30c8\u30eb\u306b\u3042\u308b\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u3078\u306e\u8a18\u9332\u3082\u5fd8\u308c\u306a\u3044\u3088\u3046\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u4f7f\u7528\u9014\u4e2d\u306e\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3055\u308c\u308b\u5834\u5408\u306f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u6dfb\u52a0\u306e\u8a18\u9332\u304c\u3042\u308b\u3053\u3068\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002\u4eca\u56de\u306e\u3088\u3046\u306bRNA\u62bd\u51fa\u306b\u5931\u6557\u3057\u306a\u3044\u3088\u3046\u3001\u53d6\u6271\u8aac\u660e\u66f8\u306b\u5f93\u3063\u3066\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u3066\u304b\u3089\u5b9f\u9a13\u3092\u59cb\u3081\u3066\u3044\u305f\u3060\u3051\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-14868\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/5e4896966c9944fcf00890f4502605bf-1.jpg\" alt=\"\" width=\"1141\" height=\"545\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/5e4896966c9944fcf00890f4502605bf-1.jpg 1141w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/5e4896966c9944fcf00890f4502605bf-1-300x143.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/5e4896966c9944fcf00890f4502605bf-1-1024x489.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/5e4896966c9944fcf00890f4502605bf-1-768x367.jpg 768w\" sizes=\"auto, (max-width: 1141px) 100vw, 1141px\" \/><\/p>\n<p>\u5f53\u793e\u3067\u306fRNA\u62bd\u51fa\u3084\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3001\u4ed6\u306b\u3082\u7d30\u80de\u57f9\u990a\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306a\u3069\u3001\u5b9f\u969b\u306b\u5b9f\u9a13\uff08\u5b9f\u7fd2\uff09\u3092\u884c\u3044\u3064\u3064\u5b66\u3079\u308b\u5404\u7a2e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3092\u958b\u50ac\u3057\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4e2d\u3067\u4eca\u56de\u306e\u3088\u3046\u306a\u5b9f\u9a13\u7d50\u679c\u3082\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u3053\u308c\u304b\u3089\u65b0\u3057\u3044\u5b9f\u9a13\u3092\u59cb\u3081\u3089\u308c\u308b\u65b9\u3001\u3088\u308a\u7406\u89e3\u3092\u6df1\u3081\u305f\u3044\u65b9\u306f\u305c\u3072\u3054\u53c2\u52a0\u304f\u3060\u3055\u3044\uff01<\/p>\n<p>DNA\/RNA\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u30ac\u30a4\u30c9\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/dna-and-rna-reference-guide-form.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a><\/p>\n<h3>DNA\/RNA\u30ec\u30d5\u30a1\u30ec\u30f3\u30b9\u30ac\u30a4\u30c9<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/dna-and-rna-reference-guide-form.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h3>\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u4e00\u89a7<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u8a73\u7d30\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u4eca\u56de\u306e\u8a18\u4e8b\u306b\u95a2\u9023\u3059\u308b\u8a18\u4e8b\uff1a<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/dna-rna-purification-analysis\/rna-extraction.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">RNA \u62bd\u51fa<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/brands\/product-brand\/purelink.html?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">PureLink \u30ad\u30c3\u30c8<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic43\/?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u6709\u6a5f\u6eb6\u5a92\uff1f\u305d\u308c\u3068\u3082\u30b7\u30ea\u30ab\u30d9\u30fc\u30b9\uff1f \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u304a\u3051\u308b\u6838\u9178\u306e\u7cbe\u88fd\u304a\u3088\u3073\u5b9a\u91cf\u65b9\u6cd5<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_3\/?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u30af\u30ed\u30ed\u30db\u30eb\u30e0\u3092\u4f7f\u308f\u305a\u306b\u30d6\u30ed\u30e2\u30af\u30ed\u30ed\u30d7\u30ed\u30d1\u30f3\u3067\u4ee3\u66ff\u3057\u3066\u307f\u305f<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_gsd_ts_1\/?CID=bid_cbu_sbu_r04_jp_cp0000_pjt0000_bid00000_0so_blg_rna_workshop_bid_ts_5_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u3092\u5e38\u6e29\u3067\u653e\u7f6e\u3057\u3066\u307f\u305f<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>RNA\u62bd\u51fa\u306b\u306f\u5bfe\u8c61\u30b5\u30f3\u30d7\u30eb\u306b\u5408\u308f\u305b\u3066\u3055\u307e\u3056\u307e\u306a\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u4e2d\u3067\u3082\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u30bf\u30a4\u30d7\u306e\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u7cbe\u88fd\u65b9\u6cd5\u306f\u8ab0\u3067\u3082\u7c21\u5358\u306b\u77ed\u6642\u9593\u3067RNA\u3092\u56de\u53ce\u3067\u304d\u308b\u65b9\u6cd5\u306e1\u3064\u3067\u3059\u3002 \u306f\u3058\u3081\u306b \u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3067RNA\u62bd\u51fa\u3059\u308b\u30ad<\/p>\n","protected":false},"author":975,"featured_media":14872,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[28,77],"division":[],"class_list":{"0":"post-14862","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-experiment","9":"tag-nucleic-acid-purification","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f\" \/>\n<meta property=\"og:description\" content=\"RNA\u62bd\u51fa\u306b\u306f\u5bfe\u8c61\u30b5\u30f3\u30d7\u30eb\u306b\u5408\u308f\u305b\u3066\u3055\u307e\u3056\u307e\u306a\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u4e2d\u3067\u3082\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u30bf\u30a4\u30d7\u306e\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u7cbe\u88fd\u65b9\u6cd5\u306f\u8ab0\u3067\u3082\u7c21\u5358\u306b\u77ed\u6642\u9593\u3067RNA\u3092\u56de\u53ce\u3067\u304d\u308b\u65b9\u6cd5\u306e1\u3064\u3067\u3059\u3002 \u306f\u3058\u3081\u306b \u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3067RNA\u62bd\u51fa\u3059\u308b\u30ad\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-07-27T07:50:06+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-03-06T08:31:43+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"443\" \/>\n\t<meta property=\"og:image:height\" content=\"211\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f\",\"datePublished\":\"2023-07-27T07:50:06+00:00\",\"dateModified\":\"2025-03-06T08:31:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/\"},\"wordCount\":83,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/rna_workshop_bid_ts_5-sumnail.jpg\",\"keywords\":[\"\u3084\u3063\u3066\u307f\u305f\",\"\u6838\u9178\u7cbe\u88fd\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/rna_workshop_bid_ts_5-sumnail.jpg\",\"datePublished\":\"2023-07-27T07:50:06+00:00\",\"dateModified\":\"2025-03-06T08:31:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/rna_workshop_bid_ts_5-sumnail.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/rna_workshop_bid_ts_5-sumnail.jpg\",\"width\":443,\"height\":211},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/rna_workshop_bid_ts_5\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f","og_description":"RNA\u62bd\u51fa\u306b\u306f\u5bfe\u8c61\u30b5\u30f3\u30d7\u30eb\u306b\u5408\u308f\u305b\u3066\u3055\u307e\u3056\u307e\u306a\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u4e2d\u3067\u3082\u30b7\u30ea\u30ab\u30e1\u30f3\u30d6\u30ec\u30f3\u30bf\u30a4\u30d7\u306e\u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u7cbe\u88fd\u65b9\u6cd5\u306f\u8ab0\u3067\u3082\u7c21\u5358\u306b\u77ed\u6642\u9593\u3067RNA\u3092\u56de\u53ce\u3067\u304d\u308b\u65b9\u6cd5\u306e1\u3064\u3067\u3059\u3002 \u306f\u3058\u3081\u306b \u30b9\u30d4\u30f3\u30ab\u30e9\u30e0\u3067RNA\u62bd\u51fa\u3059\u308b\u30ad","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-07-27T07:50:06+00:00","article_modified_time":"2025-03-06T08:31:43+00:00","og_image":[{"width":443,"height":211,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f","datePublished":"2023-07-27T07:50:06+00:00","dateModified":"2025-03-06T08:31:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/"},"wordCount":83,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg","keywords":["\u3084\u3063\u3066\u307f\u305f","\u6838\u9178\u7cbe\u88fd"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg","datePublished":"2023-07-27T07:50:06+00:00","dateModified":"2025-03-06T08:31:43+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg","width":443,"height":211},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/rna_workshop_bid_ts_5\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011RNA\u62bd\u51fa\u306b\u4f7f\u3046Wash Buffer\u306b\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u5fd8\u308c\u305f\u3089\uff1f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"},{"value":77,"label":"\u6838\u9178\u7cbe\u88fd"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg",443,211,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]},{"term_id":77,"name":"\u6838\u9178\u7cbe\u88fd","slug":"nucleic-acid-purification","term_group":0,"term_taxonomy_id":77,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/rna_workshop_bid_ts_5-sumnail.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=14862"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/14862\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/14872"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=14862"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=14862"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=14862"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=14862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}