{"id":1515,"date":"2019-02-19T00:00:00","date_gmt":"2019-02-18T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/"},"modified":"2023-08-17T16:41:54","modified_gmt":"2023-08-17T07:41:54","slug":"low_flow_rate_lc","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/","title":{"rendered":"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC"},"content":{"rendered":"<h2>\u306f\u3058\u3081\u306b<\/h2>\n<p>\u307f\u306a\u3055\u3093\u3001\u3053\u3093\u306b\u3061\u306f\u3002<br \/>\n\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u682a\u5f0f\u4f1a\u793e \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u4e8b\u696d\u90e8\u306e\u7530\u53e3\u3067\u3059\u3002<\/p>\n<p>\u304a\u5ba2\u69d8\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u30e9\u30a4\u30d5\u304c\u3069\u3046\u3057\u305f\u3089\u3088\u308a\u697d\u3057\u3044\u3082\u306e\u306b\u306a\u308b\u306e\u304b\u3001\u611b\u3059\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6280\u8853\u3068\u3068\u3082\u306b\u65e5\u3005\u3055\u307e\u3056\u307e\u306a\u3053\u3068\u306b\u596e\u95d8\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/p>\n<p>\u3055\u3066\u3001\u65e9\u901f\u3067\u3059\u304c\u3001\u307e\u305a\u306f\u8cea\u554f\u3067\u3059\u3002<\/p>\n<p>\u300c<strong>\u307f\u306a\u3055\u3093\u3001\u611f\u5ea6\u3001\u8db3\u308a\u3066\u307e\u3059\u304b\uff1f<\/strong>\u300d<\/p>\n<p>\u5404\u30e1\u30fc\u30ab\u30fc\u304b\u3089\u306f\u3044\u308d\u3044\u308d\u3068\u65b0\u88fd\u54c1\u304c\u767a\u8868\u3055\u308c\u3001\u691c\u51fa\u5668\u611f\u5ea6\u306f\u5e74\u3005\u6539\u5584\u3055\u308c\u3066\u3044\u308b\u306e\u306b\u3001\u611f\u5ea6\u554f\u984c\u306f\u306a\u304b\u306a\u304b\u4e16\u306e\u4e2d\u304b\u3089\u306a\u304f\u306a\u3063\u3066\u304f\u308c\u306a\u3044\u3067\u3059\u3088\u306d\u3002<\/p>\n<p>\u5b9f\u969b\u3001\u300c\u611f\u5ea6\u3067\u56f0\u3063\u305f\u3053\u3068\u304c\u4eca\u307e\u3067\u3042\u308a\u307e\u305b\u3093\u300d\u3068\u3044\u3046\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306f\u5c11\u6570\u6d3e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u6700\u65b0\u306e\u691c\u51fa\u5668\u3067\u3082\u611f\u5ea6\u304c\u8db3\u308a\u306a\u3044\u3068\u304d\u3001\u307e\u305f\u306f\u3001\u4eca\u3042\u308b\u691c\u51fa\u5668\u3067\u5206\u6790\u611f\u5ea6\u3092\u6539\u5584\u3057\u306a\u3051\u308c\u3070\u3044\u3051\u306a\u3044\u3068\u304d\u3001<strong>\u30a4\u30f3\u30ec\u30c3\u30c8\u306e\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08LC)\u3092\u898b\u76f4\u3059\u3053\u3068\u3067<\/strong>\u611f\u5ea6\u5411\u4e0a\u306e\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u3092\u3054\u5b58\u77e5\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>LC\u306b\u306f\u4f4e\u6d41\u91cf\u5c02\u7528\u306eLC\u304c\u3042\u308a\u3001\u7a2e\u985e\u306b\u3088\u3063\u3066\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u5b9f\u306f\u3001\u3053\u308c\u3089\u306e<strong>\u4f4e\u6d41\u91cfLC\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3067\u73fe\u5728\u306e\u611f\u5ea6\u3084\u5206\u96e2\u3092\u5411\u4e0a\u3067\u304d\u308b\u53ef\u80fd\u6027<\/strong>\u304c\u3042\u308b\u306e\u3067\u3059\u3002<\/p>\n<p>\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001<strong>\u5c11\u3057\u3067\u3082\u611f\u5ea6\u5411\u4e0a\u3092\u72d9\u3044\u305f\u3044\u65b9<\/strong>\u3001\u307e\u305f\u306f<strong>\u4f4e\u6d41\u91cfLC\u306b\u3064\u3044\u3066\u77e5\u308a\u305f\u3044\u65b9<\/strong>\u306b\u5411\u3051\u3066\u3001\u4f4e\u6d41\u91cfLC\u306e\u5b9a\u7fa9\u3084\u7a2e\u985e\u3001\u305d\u3057\u3066\u306a\u305c\u4f4e\u6d41\u91cfLC\u304c\u611f\u5ea6\u5411\u4e0a\u306b\u8ca2\u732e\u3067\u304d\u308b\u306e\u304b\u3001\u307e\u305f\u3001\u305d\u306e\u30e1\u30ea\u30c3\u30c8\u3068\u30c7\u30e1\u30ea\u30c3\u30c8\u306a\u3069\u3001\u7c21\u5358\u306b\u3001\u306a\u308b\u3079\u304f\u308f\u304b\u308a\u3084\u3059\u304f\u3054\u8aac\u660e\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/040821-nano-lc.html?ICID=cmd_chromatography_r04_jp_low_flow_rate_lc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">PDF\u7248\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>\u4f4e\u6d41\u91cfLC\u3068\u306f<\/h2>\n<p>\u4e00\u822c\u7684\u306a\u6c4e\u7528LC\u306e\u5834\u5408\u30010.1 mL\/min\u7a0b\u5ea6\u304b\u30891.0 mL\/min\u7a0b\u5ea6\u306e\u6d41\u91cf\u3067\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<p>\u4e00\u65b9\u3067\u3001\u4f4e\u6d41\u91cfLC\u306b\u306a\u308b\u3068\u3001\u3055\u3089\u306b\u4f4e\u3044\u6d41\u91cf\u3067\u4f7f\u7528\u3055\u308c\u308b\u3053\u3068\u304c\u5bb9\u6613\u306b\u60f3\u50cf\u3067\u304d\u307e\u3059\u304c\u3001\u305f\u3060\u3057\u3001\u4e00\u6982\u306b\u4f4e\u6d41\u91cfLC\u3068\u3044\u3063\u3066\u3082\u3001\u5b9f\u969b\u306b\u306f<strong>\u305d\u306e\u4f7f\u7528\u74b0\u5883\uff08\u30ab\u30e9\u30e0\u5185\u5f84\u3068\u6d41\u91cf\uff09\u306b\u3088\u3063\u3066\u4e0b\u8a18\u306e3\u3064\u306e\u30bf\u30a4\u30d7\u306b\u5206\u985e<\/strong>\u3055\u308c\u3066\u8ad6\u3058\u3089\u308c\u308b\u3053\u3068\u304c\u307b\u3068\u3093\u3069\u3067\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Fig1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5246 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Fig1.jpg\" alt=\"LC\u306b\u304a\u3051\u308b\u6d41\u91cf\u7bc4\u56f2\u3068\u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u5185\u5f84\" width=\"762\" height=\"272\" \/><\/a><\/p>\n<p style=\"text-align: center\">Fig.1 LC\u306b\u304a\u3051\u308b\u6d41\u91cf\u7bc4\u56f2\u3068\u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u5185\u5f84<\/p>\n<p style=\"text-align: center\">\u3053\u306e\u3088\u3046\u306b\u4e00\u8a00\u3067\u4f4e\u6d41\u91cfLC\u3068\u3044\u3063\u3066\u3082\u6d41\u91cf\u3084\u30ab\u30e9\u30e0\u5185\u5f84\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u30b7\u30b9\u30c6\u30e0\u304c\u5b58\u5728\u3057\u3066\u3044\u308b\u306e\u3067\u3059\u3002<\/p>\n<h2>\u306a\u305c\uff1f\u4f4e\u6d41\u91cfLC<\/h2>\n<p>LC\u306f\u4f7f\u7528\u3059\u308b\u6d41\u91cf\u3084\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306b\u3088\u3063\u3066\u305d\u306e\u5206\u985e\u304c\u5225\u308c\u308b\u306e\u3067\u3059\u304c\u3001\u306a\u305c\u4f4e\u6d41\u91cfLC\u304c\u5fc5\u8981\u306a\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u305d\u3053\u306b\u5927\u304d\u304f\u95a2\u4fc2\u3059\u308b\u306e\u306f\u3001\u611f\u5ea6\u3067\u3059\u3002<\/p>\n<p>\u4e00\u822c\u7684\u306bUV\u691c\u51fa\u5668\u3084\u8cea\u91cf\u5206\u6790\u8a08\u306e\u3088\u3046\u306a<strong>\u6fc3\u5ea6\u4f9d\u5b58\u578b\u306e\u691c\u51fa\u5668\u3067\u306f\u3001\u30ab\u30e9\u30e0\u5185\u5f84\u3092\u7e2e\u5c0f\u3059\u308b\u3068\u611f\u5ea6\u304c\u5411\u4e0a<\/strong>\u3059\u308b\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u305d\u308c\u306f\u306a\u305c\u304b\uff1f\u7406\u7531\u306f\u30ab\u30e9\u30e0\u5185\u5f84\u3068\u6d41\u91cf\u306b\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u30ab\u30e9\u30e0\u5145\u586b\u5264\u3068\u9577\u3055\u306b\u52a0\u3048\u3001\u79fb\u52d5\u76f8\u304c\u30ab\u30e9\u30e0\u5185\u3092\u9032\u3080\u901f\u5ea6\uff08\u7dda\u901f\u5ea6\uff1a\u6d41\u91cf\/\u65ad\u9762\u7a4d\uff09\u3092\u63c3\u3048\u308c\u3070\u3001\u5185\u5f84\u306e\u7570\u306a\u308b\u30ab\u30e9\u30e0\u3092\u4f7f\u3063\u305f\u5834\u5408\u3067\u3082\u3001\u7406\u8ad6\u7684\u306b\u540c\u2015\u306e\u4fdd\u6301\u6642\u9593\u3084\u5206\u96e2\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u6c4e\u7528LC\u30b9\u30b1\u30fc\u30eb\u306e\u5206\u6790\u3092\u4f4e\u6d41\u91cfLC\u306b\u79fb\u7ba1\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5185\u5f84\u306e\u5c0f\u3055\u306a\u30ab\u30e9\u30e0\uff1d\u65ad\u9762\u7a4d\u306e\u5c0f\u3055\u306a\u30ab\u30e9\u30e0\u3068\u3088\u308a\u5c0f\u3055\u306a\u6d41\u91cf\u3092\u7528\u3044\u3066\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u4f8b\u3048\u3070\u30014.6 mm\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u304b\u30891.0 \u339c\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u306b\u5909\u66f4\u3057\u305f\u5834\u5408\u3001\u65ad\u9762\u7a4d\u306f\u7d041\/20\u306b\u306a\u308b\u306e\u3067\u3001\u6d41\u91cf\u30821\/20\u306b\u306a\u308a\u307e\u3059\u3002\u540c\u4e00\u306e\u8a66\u6599\u91cf\u3092\u6ce8\u5165\u3067\u304d\u308b\u3068\u4eee\u5b9a\u3059\u308b\u3068\u3001\u30a4\u30e1\u30fc\u30b8\u3068\u3057\u3066\u306f\u3001\u8a66\u6599\u6210\u5206\u306e\u30ab\u30e9\u30e0\u5185\u306b\u304a\u3051\u308b\u5e0c\u91c8\u7387\u304c1\/20\u3068\u306a\u308b\u305f\u3081\u3001\u611f\u5ea6\u304c20\u500d\u30a2\u30c3\u30d7\u3059\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059 \u3002<\/p>\n<p>\u307e\u305f\u3001\u8cea\u91cf\u5206\u6790\u8a08\u306b\u304a\u3051\u308b\u4f4e\u6d41\u91cf\u5316\u306e\u30e1\u30ea\u30c3\u30c8\u306f\u3082\u3046\u4e00\u3064\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u305d\u308c\u306f\u30a4\u30aa\u30f3\u5316\u52b9\u7387\u306e\u6539\u5584\u3067\u3059\u3002<\/p>\n<p><strong>\u30a4\u30aa\u30f3\u5316\u52b9\u7387\u304c\u4e0a\u304c\u308b\u3053\u3068\u3067\u3001\u691c\u51fa\u90e8\u3078\u306e\u30a4\u30aa\u30f3\u5c0e\u5165\u91cf\u304c\u5897\u52a0\u3057\u3001\u611f\u5ea6\u5411\u4e0a\u304c\u898b\u8fbc\u3081\u308b<\/strong>\u306e\u3067\u3059\u3002<\/p>\n<p>\u3067\u306f\u3001\u30ab\u30e9\u30e0\u5185\u5f84\u3068\u6d41\u901f\u3092\u5909\u5316\u3055\u305b\u308b\u3068\u3001\u3069\u306e\u7a0b\u5ea6\u611f\u5ea6\u304c\u5909\u5316\u3059\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u5b9f\u969b\u306bLC-MS\u3092\u7528\u3044\u305f\u5b9f\u9a13\u7d50\u679c\u3092\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u56f3\u304b\u3089\u306f\u3001<strong>\u6d41\u91cf\u304c\u5c0f\u3055\u304f\u306b\u306a\u308b\u306b\u3064\u308c\u3066\u611f\u5ea6\u304c\u5411\u4e0a\u3057\u3066\u3044\u304f\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/strong>\u7279\u306b\u3001\u611f\u5ea6\u306e\u6539\u5584\u306f\u5206\u6790\u30b9\u30b1\u30fc\u30eb\u3088\u308a\u3082\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u3084\u30ca\u30ce\u30b9\u30b1\u30fc\u30eb\u306e\u65b9\u304c\u9855\u8457\u306b\u8868\u308c\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\uff08Fig.2 \u53c2\u7167\uff09\u3002<\/p>\n<p style=\"text-align: center\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Fig2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5250 \" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Fig2.jpg\" alt=\"\u4f4e\u6d41\u91cfLC-MS\u3067\u5f97\u3089\u308c\u308b\u611f\u5ea6\" width=\"622\" height=\"571\" \/><\/a><br \/>\nFig.2\u3000\u5206\u6790\u30d5\u30ed\u30fcLC-MS\u3068\u6bd4\u8f03\u3057\u305f\u5834\u5408\u306e\u4f4e\u6d41\u91cfLC-MS\u3067\u5f97\u3089\u308c\u308b\u611f\u5ea6<br \/>\n\u30c1\u30c8\u30af\u30ed\u30e0c\u6d88\u5316\u7269\u306e2\u7a2e\u985e\u306e\u30da\u30d7\u30c1\u30c9\uff08KGEREDLIAYLK\u3001m\/z 178.93\u30013\u4fa1\u3068EDLIAYLK\u3001m\/z 482.77\u30012\u4fa1\uff09\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u3092\u7528\u3044\u3066\u611f\u5ea6\u5411\u4e0a\u3092\u8a55\u4fa1\u3002\u30aa\u30f3\u30ab\u30e9\u30e01 pmol\u3002<\/p>\n<p style=\"text-align: left\">\u3053\u306e\u3088\u3046\u306b\u3001\u4f4e\u6d41\u901fLC\u3067\u306f\u611f\u5ea6\u304c\u6539\u5584\u3055\u308c\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002<\/p>\n<p>\u3067\u306f\u3001\u4f4e\u6d41\u91cfLC\u306b\u5206\u985e\u3055\u308c\u308b\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc LC\u3001\u30de\u30a4\u30af\u30edLC\u306f\u3069\u3093\u306a\u7279\u5fb4\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<h2>\u4f4e\u6d41\u91cfLC\u3001\u305d\u308c\u305e\u308c\u306e\u7279\u5fb4<\/h2>\n<p>\u4f4e\u6d41\u91cfLC\u306e\u305d\u308c\u305e\u308c\u306e\u7279\u5fb4\u306b\u3064\u3044\u3066\u611f\u5ea6\u3068\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306b\u7126\u70b9\u3092\u5f53\u3066\u3066\u3001\u7c21\u5358\u306b\u307e\u3068\u3081\u3066\u307f\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<h4>\u30ca\u30ceLC<\/h4>\n<p>\u5185\u5f8475 \u03bcm\u306e\u30ab\u30e9\u30e0\u3067300 nL\/min\u7a0b\u5ea6\u306e\u6d41\u91cf\u3067\u6e2c\u5b9a\u3055\u308c\u308b\u3053\u3068\u304c\u591a\u3044\u30ca\u30ce LC\u306f\u3001\u30d7\u30ed\u30c6\u30aa\u30df\u30af\u30b9\u306e\u5206\u91ce\u3067\u826f\u304f\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u30ca\u30ce LC\u3068\u8cea\u91cf\u5206\u6790\u8a08\u3092\u5408\u308f\u305b\u305f\u5206\u6790\u3067\u306f\uff11\u56de\u306e\u5206\u6790\u30675000\u7a2e\u985e\u4ee5\u4e0a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u540c\u5b9a\u304c\u53ef\u80fd\u3067\u3059\u304c\u3001\u5206\u6790\u6642\u9593\u306f1\u6642\u9593\u3092\u8d85\u3048\u3066\u3057\u307e\u3044\u307e\u3059\u3002<\/p>\n<p>\u5206\u6790\u304c\u9577\u304f\u306a\u308b\u539f\u56e0\u3068\u3057\u3066\u306f\u3044\u304f\u3064\u304b\u8003\u3048\u3089\u308c\u307e\u3059\u304c\u3001\u4f4e\u6d41\u91cfLC\u3086\u3048\u306e\u539f\u56e0\u3068\u3057\u3066\u6d41\u91cf\u306b\u5bfe\u3057\u3066\u30ab\u30e9\u30e0\u5bb9\u91cf\u304c\u5927\u304d\u304f\u306a\u308b\u306a\u3069\u306e\u7269\u7406\u7684\u306a\u8981\u4ef6\u304c\u5206\u6790\u6642\u9593\u306b\u5927\u304d\u304f\u5f71\u97ff\u3059\u308b\u3053\u3068\u304c\u3042\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b<strong>\u30ca\u30ce LC\u3067\u306f\u611f\u5ea6\u3084\u5206\u96e2\u6539\u5584\u304c\u898b\u8fbc\u3081\u308b<\/strong>\u4e00\u65b9\u3067\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5411\u4e0a\u306f\u96e3\u3057\u304f\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h4>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC<\/h4>\n<p>\u5185\u5f84100\uff5e300 \u03bcm\u306e\u30ab\u30e9\u30e0\u30671\uff5e15 \u03bcL\/min\u306e\u6d41\u901f\u3067\u6e2c\u5b9a\u3055\u308c\u308b\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc LC\u306f\u3001\u5206\u6790\u30b9\u30b1\u30fc\u30eb\u306eLC\u3068\u6bd4\u8f03\u3057\u3066\u611f\u5ea6\u306e\u5411\u4e0a\u3084\u6eb6\u5a92\u4f7f\u7528\u91cf\u306e\u524a\u6e1b\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u30ca\u30ce LC\u3068\u6bd4\u8f03\u3059\u308b\u3068\u3001\u6d41\u91cf\u304c\u65e9\u304f\u306a\u308b\u305f\u3081\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5411\u4e0a\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u611f\u5ea6\u9762\u3067\u306f\u540c\u91cf\u6ce8\u5165\u3059\u308b\u3053\u3068\u3092\u8003\u3048\u308b\u3068\u30ca\u30ce LC\u307b\u3069\u306e\u611f\u5ea6\u306f\u671f\u5f85\u3067\u304d\u307e\u305b\u3093\u304c\u3001<strong>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc LC\u3067\u306f\u30ab\u30e9\u30e0\u306e\u5185\u5f84\u304c\u5927\u304d\u3044\u306e\u3067\u30ab\u30e9\u30e0\u306b\u30ed\u30fc\u30c9\u3067\u304d\u308b\u30b5\u30f3\u30d7\u30eb\u91cf\u304c\u591a\u304f\u306a\u308a\u3001\u30ca\u30ce LC\u3068\u540c\u7b49\u306e\u611f\u5ea6\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd<\/strong>\u3067\u3059\u3002<\/p>\n<h4>\u30de\u30a4\u30af\u30edLC<\/h4>\n<p>\u5185\u5f840.3\uff5e1.0 mm\u306e\u30ab\u30e9\u30e0\u306710\uff5e100 \u03bcL\/min\u306e\u6d41\u901f\u3067\u6e2c\u5b9a\u3055\u308c\u308b\u30de\u30a4\u30af\u30ed LC\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3068\u540c\u69d8\u306b\u5206\u6790\u30b9\u30b1\u30fc\u30eb\u306eLC\u3068\u6bd4\u8f03\u3057\u3066\u611f\u5ea6\u306e\u5411\u4e0a\u3084\u6eb6\u5a92\u4f7f\u7528\u91cf\u306e\u524a\u6e1b\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u304c\u3001\u305d\u306e\u52b9\u679c\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u307b\u3069\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u3057\u304b\u3057\u3001<strong>\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304c\u9ad8\u3044\u306e\u3067\u3001\u5206\u6790\u30b9\u30b1\u30fc\u30eb\u3088\u308a\u5c11\u3057\u3060\u3051\u611f\u5ea6\u3092\u4e0a\u3052\u305f\u3044\u3068\u304d\u306b\u6709\u52b9<\/strong>\u3067\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b\u4f4e\u6d41\u91cfLC\u306f\u305d\u308c\u305e\u308c\u7570\u306a\u308b\u7279\u5fb4\u3092\u6709\u3057\u3066\u304a\u308a\u3001\u611f\u5ea6\u3068\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306b\u3064\u3044\u3066\u7c21\u5358\u306b\u307e\u3068\u3081\u308b\u3068\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Table1-1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5266 \" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Table1-1.jpg\" alt=\"\u611f\u5ea6\u3068\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u6027\u306e\u95a2\u4fc2\" width=\"538\" height=\"125\" \/><\/a><\/p>\n<p style=\"text-align: center\">Table1\u3000\u611f\u5ea6\u3068\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u95a2\u4fc2<\/p>\n<h2>\u4f4e\u6d41\u91cfLC\u30b7\u30b9\u30c6\u30e0\u306e\u6d41\u91cf\u7ba1\u7406<\/h2>\n<p>\u4f4e\u6d41\u91cfLC\u5206\u6790\u3067\u306f\u3001\u5206\u6790\u30b9\u30b1\u30fc\u30eb\u3088\u308a\u3082\u30b7\u30b9\u30c6\u30e0\u306e\u6d41\u91cf\u7ba1\u7406\u304c\u96e3\u3057\u3044\u305f\u3081\u3001<strong>\u4f4e\u6d41\u91cf\u5c02\u7528\u306e\u30b7\u30b9\u30c6\u30e0\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/strong><\/p>\n<p>\u4f8b\u3048\u3070\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/ULTIM3000RSLCNANO?ICID=cmd_chromatography_r04_jp_low_flow_rate_lc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Scientific\u2122 UltiMate\u2122 3000 RSLCnano\u30b7\u30b9\u30c6\u30e0<\/a>\u3067\u306f\u3001\u5341\u5206\u306a\u6027\u80fd\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u30d5\u30ed\u30fc\u30e1\u30fc\u30bf\u30fc\u3068\u3044\u3046\u30e2\u30b8\u30e5\u30fc\u30eb\u578b\u30d1\u30fc\u30c4\u306b\u3088\u3063\u3066\u6d41\u91cf\u7ba1\u7406\u304c\u884c\u308f\u308c\u307e\u3059\u3002<\/p>\n<p>\u30d5\u30ed\u30fc\u30e1\u30fc\u30bf\u30fc\u306f\u63a8\u5968\u6d41\u91cf\u7bc4\u56f2\u306b\u3088\u3063\u3066\u30ca\u30ce\uff0850 nL\/min\uff5e1.5 \u03bcL\/min\uff09\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\uff080.5\uff5e10 \u03bcL\/min\uff09\u3001\u30de\u30a4\u30af\u30ed\uff085\uff5e50 \u03bcL\/min\uff09\u306e3\u3064\u306b\u5206\u304b\u308c\u3066\u304a\u308a\u3001\u3053\u308c\u3089\u306e\u30d5\u30ed\u30fc\u30e1\u30fc\u30bf\u30fc\u3092\u5165\u308c\u66ff\u3048\u308b\u3053\u3068\u3067\u3001\u3088\u308a\u6b63\u78ba\u306a\u9001\u6db2\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002\u3082\u3061\u308d\u3093\u3001<strong>\u30d5\u30ed\u30fc\u30e1\u30fc\u30bf\u30fc\u306f\u30e6\u30fc\u30b6\u30fc\u304c\u4ea4\u63db\u304c\u3067\u304d\u308b\u306e\u3067\u3001\u4e00\u53f0\u306e\u88c5\u7f6e\u3067\u5e45\u5e83\u3044\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5bfe\u5fdc\u3067\u304d\u307e\u3059\u3002<\/strong><\/p>\n<p>\u307e\u305f\u3001\u4e00\u65b9\u3067\u6d41\u91cf\u7ba1\u7406\u306b\u30d5\u30ed\u30fc\u30bb\u30f3\u30b5\u30fc\u3092\u4f7f\u3063\u305f\u4f4e\u6d41\u91cf\u30b7\u30b9\u30c6\u30e0\u3082\u5b58\u5728\u3057\u307e\u3059\u3002<\/p>\n<p>\u4f8b\u3048\u3070\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/LC140?ICID=cmd_chromatography_r04_jp_low_flow_rate_lc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Thermo Scientific\u2122 EASY-nLC\u2122 1200 \u30b7\u30b9\u30c6\u30e0<\/a>\u3067\u306f\u642d\u8f09\u3055\u308c\u305f\u9ad8\u5727\u30dd\u30f3\u30d7\u306eA\u30e9\u30a4\u30f3\u3068B\u30e9\u30a4\u30f3\u306e\u6d41\u8def\u4e0a\u306b\u30d5\u30ed\u30fc\u30bb\u30f3\u30b5\u30fc\u304c\u8a2d\u7f6e\u3055\u308c\u3066\u304a\u308a\u3001\u305d\u308c\u305e\u308c\u306e\u6eb6\u5a92\u9001\u6db2\u3092\u5236\u5fa1\u3059\u308b\u3053\u3068\u3067\u4f4e\u6d41\u91cf\u57df\u306b\u3088\u308b\u9001\u6db2\u6027\u80fd\u3092\u9ad8\u3081\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3061\u306a\u307f\u306b\u3053\u306e\u30b7\u30b9\u30c6\u30e0\u3001\u30bf\u30c3\u30c1\u30d1\u30cd\u30eb\u304b\u3089\u64cd\u4f5c\u304c\u53ef\u80fd\u3067\u975e\u5e38\u306b\u30b3\u30f3\u30d1\u30af\u30c8\u306a\u30b7\u30b9\u30c6\u30e0\uff0845 cm x 36 cm x 38 cm\u300137 kg\uff09\u306e\u305f\u3081\u3001\u6c17\u8efd\u306b\u79fb\u52d5\u3082\u3067\u304d\u3001<strong>\u3055\u307e\u3056\u307e\u306a\u30d9\u30f3\u30c0\u30fc\u691c\u51fa\u5668\u306eLC\u90e8\u5206\u3092\u30ab\u30f3\u30bf\u30f3\u306b\u4f4e\u6d41\u91cf\u5316\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/strong><\/p>\n<p>&nbsp;<\/p>\n<h2>\u4f4e\u6d41\u91cfLC\u306e\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165<\/h2>\n<p>\u4f4e\u6d41\u91cfLC\u306e\u4e2d\u3067\u3082\u7279\u306b\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u3084\u30ca\u30ce\u30b9\u30b1\u30fc\u30eb\u3067\u306e\u5206\u6790\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u5bb9\u91cf\u304c\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30c7\u30a3\u30ec\u30a4\u5bb9\u91cf\u306b\u5927\u304d\u304f\u5f71\u97ff\u3057\u307e\u3059\u3002<\/p>\n<p>\u6ce8\u5165\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u5bb9\u91cf\uff09\u304c 1 \u03bcL\u7a0b\u5ea6\u3067\u3042\u308c\u3070\u554f\u984c\u306a\u3044\u306e\u3067\u3059\u304c\u3001<strong>\u30b5\u30f3\u30d7\u30eb\u3092\u5927\u91cf\u306b\u6ce8\u5165\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u9001\u6db2\u30b9\u30d4\u30fc\u30c9\uff08\u6d41\u91cf\u306e\u8a2d\u5b9a\uff09\u304c\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306b\u5927\u304d\u304f\u5f71\u97ff<\/strong>\u3057\u307e\u3059\u3002<\/p>\n<p>\u305d\u306e\u7406\u7531\u3068\u3057\u3066\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u3084\u30ca\u30ce\u30b9\u30b1\u30fc\u30eb\u306b\u304a\u3044\u3066\u306f\u6d41\u91cf\u304c300 nL\/min\u7a0b\u5ea6\uff5e\u6570\u03bcL\/min\u3068\u9045\u304f\u3001\u6ce8\u5165\uff08\u30ed\u30fc\u30c9\uff09\u306b\u9577\u3044\u6642\u9593\u304c\u304b\u304b\u3063\u3066\u3057\u307e\u3046\u305f\u3081\u3067\u3059\u3002<\/p>\n<p>\u305d\u306e\u305f\u3081\u3001\u4f4e\u6d41\u91cfLC\u3067\u5927\u91cf\u6ce8\u5165\u3092\u884c\u3046\u5834\u5408\u306f\u3001\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u4e88\u5099\u6fc3\u7e2e\uff08Trap-elute\uff09\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u307e\u3059\u3002\u3053\u306e\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u901a\u5e38\u306e\u5206\u6790\u7528\u30dd\u30f3\u30d7\u306b\u52a0\u3048\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u7528\u30dd\u30f3\u30d7\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/p>\n<p>\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u30dd\u30f3\u30d7\u306b\u3088\u308a\u30b5\u30f3\u30d7\u30eb\u304c\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u306b\u8fc5\u901f\u306b\u30ed\u30fc\u30c9\u3055\u308c\u308b\u305f\u3081\u3001<strong>\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u306b\u3088\u308b\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u60aa\u5316\u3092\u9632\u3050<\/strong>\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4e88\u5099\u6fc3\u7e2e\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3053\u308c\u4ee5\u5916\u306b\u3082\u3001<strong>\u30b5\u30f3\u30d7\u30eb\u3092\u6fc3\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3001\u30ab\u30e9\u30e0\u306b\u4fdd\u6301\u3055\u308c\u306a\u3044\u5869\u306a\u3069\u3092\u9664\u53bb\u3057\u3066\u30b5\u30f3\u30d7\u30eb\u306e\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u304c\u3067\u304d\u308b\u306a\u3069\u306e\u5229\u70b9\u3082\u3042\u308a\u307e\u3059\u3002<\/strong><\/p>\n<p>\u76f4\u63a5\u6ce8\u5165\u30b7\u30b9\u30c6\u30e0\u3068\u4e88\u5099\u6fc3\u7e2e\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308b\u3001\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\u306e\u9055\u3044\u3092\u7c21\u5358\u306b\u793a\u3057\u307e\u3059\uff08Fig.3\u53c2\u7167\uff09\u3002\u4e88\u5099\u6fc3\u7e2e\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u304b\u3089\u6ce8\u5165\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u306f\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u30dd\u30f3\u30d7\uff08\u9ec4\u8272\uff09\u3067\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u306b\u904b\u3070\u308c\u307e\u3059\u3002\u30c8\u30e9\u30c3\u30d7\u3055\u305b\u305f\u5f8c\u306b\u30d0\u30eb\u30d6\u3092\u5207\u308a\u66ff\u3048\u308b\u3068\u3001\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u3068\u5206\u6790\u30ab\u30e9\u30e0\u304c\u76f4\u5217\u306b\u3064\u306a\u304c\u308b\u306e\u3067\u3001\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u306b\u30c8\u30e9\u30c3\u30d7\u3055\u308c\u3066\u3044\u308b\u5316\u5408\u7269\u304c\u5206\u6790\u30ab\u30e9\u30e0\u3067\u5206\u96e2\u3055\u308c\u307e\u3059\u3002<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Fig3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5251\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/Fig3.jpg\" alt=\"\u4f4e\u6d41\u91cfHPLC\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165\" width=\"506\" height=\"228\" \/><\/a><\/p>\n<p style=\"text-align: center\">Fig.3\u3000\u4f4e\u6d41\u91cfHPLC\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u6ce8\u5165<br \/>\n\u5de6\uff1a\u76f4\u63a5\u6ce8\u5165\u3000\u53f3\uff1a\u4e88\u5099\u6fc3\u7e2e<br \/>\n\u9752\uff1a\u5206\u6790\u7528\u4f4e\u6d41\u91cf\u9ad8\u5727\u30dd\u30f3\u30d7\u3068\u5bfe\u5fdc\u3059\u308b\u6d41\u8def\u306e\u63a5\u7d9a<br \/>\n\u9ec4\uff1a\u30b5\u30f3\u30d7\u30eb\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u7528\u30dd\u30f3\u30d7\u3068\u5bfe\u5fdc\u3059\u308b\u6d41\u8def\u306e\u63a5\u7d9a<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4ee5\u4e0a\u3001\u4f4e\u6d41\u91cfLC\u306e\u7279\u5fb4\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002<\/p>\n<p>\u30a4\u30f3\u30ec\u30c3\u30c8\u306eLC\u3092\u898b\u76f4\u3059\u3053\u3068\u3067\u611f\u5ea6\u306b\u95a2\u3059\u308b\u8ab2\u984c\u3092\u89e3\u6c7a\u3067\u304d\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u304c\u304a\u5206\u304b\u308a\u9802\u3051\u305f\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u3082\u3061\u308d\u3093\u3001\u691c\u51fa\u5668\u306e\u5909\u66f4\u3084\u524d\u51e6\u7406\u306e\u5de5\u592b\u3068\u3044\u3063\u305f\u5225\u306e\u9078\u629e\u80a2\u304c\u6709\u52b9\u306a\u30b1\u30fc\u30b9\u3082\u3042\u308a\u307e\u3059\u304c<br \/>\n\u30a4\u30f3\u30ec\u30c3\u30c8\u306eLC\u306e\u898b\u76f4\u3057\u306b\u3088\u3063\u3066\u8ab2\u984c\u3092\u89e3\u6c7a\u3057\u305f\u3044\u3068\u304d\u306b\u306f\u3001\u611f\u5ea6\u3068\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u30d0\u30e9\u30f3\u30b9\u3092\u8003\u616e\u3057\u76ee\u7684\u306b\u4f1a\u3063\u305f\u30b7\u30b9\u30c6\u30e0\u3092\u9078\u3076\u3053\u3068\u304c\u4f4e\u6d41\u91cfLC\u3067\u306f\u91cd\u8981\u3067\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<p>\u4ee5\u4e0b\u306b\u4eca\u56de\u3054\u7d39\u4ecb\u3057\u305f\u88fd\u54c1\u306e\u95a2\u9023\u30da\u30fc\u30b8\u3082\u3054\u3056\u3044\u307e\u3059\u306e\u3067\u3001\u3054\u8208\u5473\u3042\u308b\u65b9\u306f\u305d\u3061\u3089\u3082\u662f\u975e\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/040821-nano-lc.html?ICID=cmd_chromatography_r04_jp_low_flow_rate_lc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">PDF\u7248\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u307e\u305f\u3001\u304a\u554f\u3044\u5408\u308f\u305b\u304b\u3089\u88fd\u54c1\u306b\u95a2\u3059\u308b\u3054\u8cea\u554f\u3084\u898b\u7a4d\u3082\u308a\u4f9d\u983c\u306a\u3069\u3082\u304a\u5f85\u3061\u3057\u3066\u304a\u308a\u307e\u3059\uff01<\/p>\n<p>\u4e0b\u8a18\u30d5\u30a9\u30fc\u30e0\u304b\u3089\u304a\u6c17\u8efd\u306b\u3054\u9023\u7d61\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u95a2\u9023\u60c5\u5831<\/h2>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/liquid-chromatography-lc\/hplc-uhplc-systems.html?ICID=cmd_chromatography_r04_jp_low_flow_rate_lc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u4f4e\u6d41\u91cfLC\u88fd\u54c1\u60c5\u5831<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/easy-nlc_voc\/?ICID=cmd_chromatography_r04_jp_low_flow_rate_lc_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\"><span class=\"no-wow\">\u3010\u304a\u5ba2\u69d8\u4e8b\u4f8b\uff1a\u30a2\u30ab\u30c7\u30df\u30a2\u3011\u8840\u6db2\u4e00\u6ef4\u306e\u53ef\u80fd\u6027\u3092\u62d3\u304f\u30fc\u30fc\u30fc\u6c38\u7d9a\u53ef\u80fd\u306a\u30d7\u30ed\u30c6\u30aa\u30df\u30af\u30b9\u7814\u7a76\u306e\u5834\u3092\u5275\u9020\u3059\u308b<\/span><\/a><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u306f\u3058\u3081\u306b \u307f\u306a\u3055\u3093\u3001\u3053\u3093\u306b\u3061\u306f\u3002 \u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u682a\u5f0f\u4f1a\u793e \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u4e8b\u696d\u90e8\u306e\u7530\u53e3\u3067\u3059\u3002 \u304a\u5ba2\u69d8\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u30e9\u30a4\u30d5\u304c\u3069\u3046\u3057\u305f\u3089\u3088\u308a\u697d\u3057\u3044\u3082\u306e\u306b\u306a\u308b\u306e\u304b\u3001\u611b<\/p>\n","protected":false},"author":988,"featured_media":5052,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[],"division":[],"class_list":["post-1515","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC\" \/>\n<meta property=\"og:description\" content=\"\u306f\u3058\u3081\u306b \u307f\u306a\u3055\u3093\u3001\u3053\u3093\u306b\u3061\u306f\u3002 \u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u682a\u5f0f\u4f1a\u793e \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u4e8b\u696d\u90e8\u306e\u7530\u53e3\u3067\u3059\u3002 \u304a\u5ba2\u69d8\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u30e9\u30a4\u30d5\u304c\u3069\u3046\u3057\u305f\u3089\u3088\u308a\u697d\u3057\u3044\u3082\u306e\u306b\u306a\u308b\u306e\u304b\u3001\u611b\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2019-02-18T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-17T07:41:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"13\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC\",\"datePublished\":\"2019-02-18T15:00:00+00:00\",\"dateModified\":\"2023-08-17T07:41:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/\"},\"wordCount\":132,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/liquid-chromatography.png\",\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/\",\"name\":\"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/liquid-chromatography.png\",\"datePublished\":\"2019-02-18T15:00:00+00:00\",\"dateModified\":\"2023-08-17T07:41:54+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/liquid-chromatography.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/liquid-chromatography.png\",\"width\":1200,\"height\":630,\"caption\":\"liquid chromatography_low_flow_rate_lc\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/low_flow_rate_lc\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/","og_locale":"ja_JP","og_type":"article","og_title":"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC","og_description":"\u306f\u3058\u3081\u306b \u307f\u306a\u3055\u3093\u3001\u3053\u3093\u306b\u3061\u306f\u3002 \u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u682a\u5f0f\u4f1a\u793e \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u4e8b\u696d\u90e8\u306e\u7530\u53e3\u3067\u3059\u3002 \u304a\u5ba2\u69d8\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc&amp;MS\u30e9\u30a4\u30d5\u304c\u3069\u3046\u3057\u305f\u3089\u3088\u308a\u697d\u3057\u3044\u3082\u306e\u306b\u306a\u308b\u306e\u304b\u3001\u611b","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2019-02-18T15:00:00+00:00","article_modified_time":"2023-08-17T07:41:54+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography.png","type":"image\/png"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"13\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC","datePublished":"2019-02-18T15:00:00+00:00","dateModified":"2023-08-17T07:41:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/"},"wordCount":132,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography.png","articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/","name":"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography.png","datePublished":"2019-02-18T15:00:00+00:00","dateModified":"2023-08-17T07:41:54+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography.png","width":1200,"height":630,"caption":"liquid chromatography_low_flow_rate_lc"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/low_flow_rate_lc\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u306f\u3058\u3081\u3066\u306e\u4f4e\u6d41\u91cfLC\uff5e\u30ca\u30ceLC\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcLC\u3001\u30de\u30a4\u30af\u30edLC"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography-1024x538.png",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":1515,"position":0},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":1515,"position":1},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":1515,"position":2},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":1515,"position":3},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25673,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-semiconductors-cmd-26028\/","url_meta":{"origin":1515,"position":4},"title":"\u534a\u5c0e\u4f53\u88fd\u9020\u306b\u304a\u3051\u308bIC\u306e\u5f79\u5272","author":"LatB Staff","date":"2026\u5e7410\u67082\u65e5","format":false,"excerpt":"\u30b9\u30de\u30fc\u30c8\u30d5\u30a9\u30f3\u3084AI\u30b5\u30fc\u30d0\u30fc\u3001\u81ea\u52d5\u8eca\u306a\u3069\u3001\u79c1\u305f\u3061\u306e\u8eab\u306e\u56de\u308a\u306b\u3042\u308b\u96fb\u5b50\u6a5f\u5668\u306e\u591a\u304f\u306f\u534a\u5c0e\u4f53\u306b\u3088\u3063\u3066\u652f\u3048\u3089\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/09\/ion-chromatography-semiconductors-cmd-26028_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24408,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elemental-analysis-case-introduction-cmd-25076\/","url_meta":{"origin":1515,"position":5},"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u7c89\u672b\u8a66\u6599\u306e\u8fc5\u901f\u30fb\u9ad8\u611f\u5ea6\u306a\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2025\u5e7412\u670812\u65e5","format":false,"excerpt":"\u5316\u5b66\u54c1\u3084\u5de5\u696d\u6750\u6599\u306e\u539f\u6599\u3001\u304a\u3088\u3073\u4e8c\u6b21\u96fb\u6c60\u5411\u3051\u306e\u6a5f\u80fd\u6027\u6750\u6599\u306a\u3069\u3001\u7c89\u672b\u8a66\u6599\u3084\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u6750\u6599\u4e2d\u306e\u5fae\u91cf\u5143\u7d20\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/liquid-chromatography.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1515"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1515\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/5052"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1515"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1515"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1515"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}