{"id":15355,"date":"2023-09-19T15:14:04","date_gmt":"2023-09-19T06:14:04","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=15355"},"modified":"2024-09-18T16:03:45","modified_gmt":"2024-09-18T07:03:45","slug":"ce_basic_dna_gsd_ts_3-2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/","title":{"rendered":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db"},"content":{"rendered":"<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u3001\u30c7\u30fc\u30bf\u304c\u30a2\u30ca\u30ed\u30b0\u4fe1\u53f7\u304b\u3089\u30c7\u30b8\u30bf\u30eb\u4fe1\u53f7\u306b\u5909\u63db\u3055\u308c\u3001\u54c1\u8cea\u30b9\u30b3\u30a2\u3068\u3068\u3082\u306b\u5869\u57fa\u304c\u5272\u308a\u5f53\u3066\u3089\u308c\u308b\u307e\u3067\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u5909\u63db<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_2\/?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d6\u30ed\u30b0 \u201c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 \uff5e\u305d\u306e\uff11\uff1aDNA\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30b4\u30fc\u30eb\u30c9\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306b\u306a\u308b\u307e\u3067\uff5e\u201d<\/a> \u3067\u306f\u3001\u653e\u5c04\u6027\u7269\u8cea\u3068 X \u7dda\u30d5\u30a3\u30eb\u30e0\u3092\u7528\u3044\u305f\u691c\u51fa\u304b\u3089\u3001\u86cd\u5149\u7269\u8cea\u3068\u5149\u5b66\u7cfb\u3067\u306e\u691c\u51fa\u3078\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u6280\u8853\u306e\u5909\u9077\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u4eca\u56de\u306f\u3001\u86cd\u5149\u7269\u8cea\u3068\u5149\u5b66\u7cfb\u3067\u306e\u691c\u51fa\u306b\u304a\u3051\u308b\u3001\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u30c7\u30fc\u30bf\u5909\u63db\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<br \/>\n\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3067\u306f\u3001\u4f38\u9577\u3055\u308c\u305fDNA\u65ad\u7247\u306e3\u00b4\u672b\u7aef\u306b\u86cd\u5149\u6a19\u8b58\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\u304c\u53d6\u308a\u8fbc\u307e\u308c\u308b\u3053\u3068\u3067\u3001\u86cd\u5149\u6a19\u8b58\u3055\u308c\u305fDNA\u65ad\u7247\u304c\u3064\u304f\u3089\u308c\u307e\u3059\uff08\u56f31\uff09\u3002\u86cd\u5149\u8272\u7d20\u306f4\u7a2e\u7528\u3044\u3089\u308c\u3001\u5869\u57fa\u3054\u3068\u306b\u7570\u306a\u308b\u86cd\u5149\u8272\u7d20\u304c\u6a19\u8b58\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u3067\u306f\u3001\u691c\u51fa\u3055\u308c\u308b\u86cd\u5149\u6ce2\u9577\u306e\u9055\u3044\u304b\u3089\u3001\u5869\u57fa\u306e\u7a2e\u985e\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15358\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15358\" class=\"size-large wp-image-15358\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/3e64595579600aa8e8b345634e6c79c5-1024x357.jpg\" alt=\"\u56f31. \u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u6982\u5ff5\u56f3\" width=\"760\" height=\"265\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/3e64595579600aa8e8b345634e6c79c5-1024x357.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/3e64595579600aa8e8b345634e6c79c5-300x105.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/3e64595579600aa8e8b345634e6c79c5-768x268.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/3e64595579600aa8e8b345634e6c79c5.jpg 1109w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-15358\" class=\"wp-caption-text\">\u56f31. \u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u6982\u5ff5\u56f3<\/p><\/div>\n<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u306b\u306f\u3001\u30ec\u30fc\u30b6\u30fc\u5149\u6e90\u3068\u96fb\u8377\u7d50\u5408\u7d20\u5b50\uff08CCD\uff09\u304c\u642d\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u3067\u306f\u3001\u524d\u8ff0\u306e\u86cd\u5149\u6a19\u8b58\u3055\u308c\u305fDNA\u65ad\u7247\u304c\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306b\u53d6\u308a\u8fbc\u307e\u308c\u3001\u6cf3\u52d5\u3055\u308c\u307e\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306b\u30ec\u30fc\u30b6\u30fc\u5149\u304c\u7167\u5c04\u3055\u308c\u308b\u3068\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u5185\u90e8\u306e\u86cd\u5149\u8272\u7d20\u304c\u52b1\u8d77\u3055\u308c\u3001\u7279\u5b9a\u306e\u30b9\u30da\u30af\u30c8\u30eb\u3092\u3082\u3064\u5149\u304c\u653e\u51fa\u3055\u308c\u307e\u3059\u3002\u653e\u51fa\u3055\u308c\u305f\u5149\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b5\u30fc\u5185\u90e8\u306eCCD\u3067\u691c\u51fa\u3055\u308c\u307e\u3059\u3002<br \/>\n\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u53d6\u5f97\u3055\u308c\u308b\u30c7\u30fc\u30bf\u306f\u3001Applied Biosystems\u2122 Data Collection\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u53ce\u96c6\u3055\u308c\u307e\u3059\u3002Data Collection\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u3001\u30e6\u30fc\u30b6\u30fc\u304c\u6a5f\u5668\u3092\u64cd\u4f5c\u3059\u308b\u305f\u3081\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u3001\u96fb\u5727\u3001\u6cf3\u52d5\u6642\u9593\u3001\u9069\u7528\u3059\u308b\u30d5\u30a3\u30eb\u30bf\u30fc\u3001\u30ab\u30e1\u30e9\u30b9\u30d4\u30fc\u30c9\u306a\u3069\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u8abf\u6574\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u96fb\u6c17\u6cf3\u52d5\u3067\u306f\u3001\u96fb\u5727\u3068\u6642\u9593\u304c\u3001\u6cf3\u52d5\u901f\u5ea6\u3068\u30d4\u30fc\u30af\u5206\u96e2\u80fd\u306b\u5f71\u97ff\u3059\u308b\u4e3b\u8981\u306a\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3068\u306a\u308a\u307e\u3059\u3002<br \/>\nCCD\u3067\u691c\u51fa\u3055\u308c\u308b\u86cd\u5149\u8272\u7d20\u306e\u86cd\u5149\u30b9\u30da\u30af\u30c8\u30eb\u306f\u30d6\u30ed\u30fc\u30c9\u3067\u3042\u308a\u3001\u8272\u7d20\u9593\u3067\u30b9\u30da\u30af\u30c8\u30eb\u306e\u88fe\u304c\u91cd\u306a\u308a\u307e\u3059\uff08\u56f32\uff09\u3002\u30b9\u30da\u30af\u30c8\u30eb\u304c\u91cd\u306a\u308b\u6bd4\u7387\u306f\u5e38\u306b\u4e00\u5b9a\u3067\u3042\u308a\u3001\u6570\u5b66\u7684\u306b\u5dee\u3057\u5f15\u304f\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002Data Collection\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f CCD \u304b\u3089\u86cd\u5149\u30b9\u30da\u30af\u30c8\u30eb\u60c5\u5831\u3092\u53d6\u5f97\u3057\u3001\u4f7f\u7528\u3059\u308b\u86cd\u5149\u8272\u7d20\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u5fdc\u3058\u3066\u3001\u30b9\u30da\u30af\u30c8\u30eb\u9593\u306e\u91cd\u8907\u60c5\u5831\u3092\u53d6\u308a\u9664\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u30014\u3064\u306e\u86cd\u5149\u8272\u7d20\u304c\u6b63\u3057\u304f\u8a8d\u8b58\u3055\u308c\u307e\u3059\u3002<br \/>\n\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u3001\u3053\u306e\u86cd\u5149\u5f37\u5ea6\u30c7\u30fc\u30bf\u3092\u201dAB1\u201d\u3068\u547c\u3070\u308c\u308b\u30d5\u30a1\u30a4\u30eb\u306b\u51fa\u529b\u3057\u307e\u3059\uff08\u751f\u6210\u3055\u308c\u305f\u30d5\u30a1\u30a4\u30eb\u306e\u62e1\u5f35\u5b50\u304c.ab1\u3067\u3042\u308b\u305f\u3081\u3001AB1\u30d5\u30a1\u30a4\u30eb\u3068\u547c\u3070\u308c\u307e\u3059\uff09\u3002<br \/>\n\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u5834\u5408\u3001\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u3055\u3089\u306b\u4f7f\u7528\u3057\u305f\u6a5f\u5668\u3001\u30dd\u30ea\u30de\u30fc\u3001\u86cd\u5149\u8272\u7d20\u306b\u5fdc\u3058\u3066\u3001\u79fb\u52d5\u5ea6\u306e\u88dc\u6b63\u3092\u884c\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u3001\u5404\u30d4\u30fc\u30af\u306b\u500b\u3005\u306e\u5869\u57fa\u304c\u30b3\u30fc\u30eb\u3055\u308c\u3001\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30b7\u30b0\u30ca\u30eb\u30ce\u30a4\u30ba \uff08\u7279\u5b9a\u4f4d\u7f6e\u306b\u307f\u3089\u308c\u308b\u4ed6\u306e\u8272\u7d20\u306e\u30b7\u30b0\u30ca\u30eb\uff09\u304c\u89e3\u6790\u3055\u308c\u3066\u3001\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5869\u57fa\u306b\u54c1\u8cea\u30b9\u30b3\u30a2\u304c\u5272\u308a\u5f53\u3066\u3089\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15359\" style=\"width: 542px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15359\" class=\"wp-image-15359\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/bb563e374e2a169336ebc0009b063ac0-1024x706.jpg\" alt=\"\u56f32. 4\u7a2e\u306e\u86cd\u5149\u8272\u7d20\u306e\u86cd\u5149\u30b9\u30da\u30af\u30c8\u30eb\u6982\u5ff5\u56f3\" width=\"532\" height=\"367\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/bb563e374e2a169336ebc0009b063ac0-1024x706.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/bb563e374e2a169336ebc0009b063ac0-300x207.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/bb563e374e2a169336ebc0009b063ac0-768x529.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/bb563e374e2a169336ebc0009b063ac0-96x65.jpg 96w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/bb563e374e2a169336ebc0009b063ac0.jpg 1055w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><p id=\"caption-attachment-15359\" class=\"wp-caption-text\">\u56f32. 4\u7a2e\u306e\u86cd\u5149\u8272\u7d20\u306e\u86cd\u5149\u30b9\u30da\u30af\u30c8\u30eb\u6982\u5ff5\u56f3<\/p><\/div>\n<h2>\u5869\u57fa\u306b\u5272\u308a\u5f53\u3066\u3089\u308c\u308b\u54c1\u8cea\u30b9\u30b3\u30a2<\/h2>\n<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308b\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30a8\u30e9\u30fc\u30e2\u30c7\u30eb\u306f\u3001Phil Green\u306b\u3088\u3063\u3066\u958b\u767a\u3055\u308c\u305f\u3001Phred\u3068\u547c\u3070\u308c\u308b\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u3088\u308a\u5b9a\u91cf\u5316\u3055\u308c\u307e\u3059\u3002Phred\u54c1\u8cea\u30b9\u30b3\u30a2Q\u306f\u3001\u30a8\u30e9\u30fc\u78ba\u7387P\u306e\u95a2\u6570\u3068\u3057\u3066\u3001Q = -10 log<sub>10<\/sub>(P) \u3068\u5b9a\u7fa9\u3055\u308c\u307e\u3059\u3002\u54c1\u8cea\u30b9\u30b3\u30a220\u306f\u3001\u30a8\u30e9\u30fc\u78ba\u7387\u304c100 \u5206\u306e 1 \u3001\u7cbe\u5ea6\u306f99%\u3067\u3042\u308b\u3053\u3068\u3092\u793a\u3057\u307e\u3059\u3002\u54c1\u8cea\u30b9\u30b3\u30a2 30 \u306f\u3001\u30a8\u30e9\u30fc\u78ba\u73871000 \u5206\u306e 1\u3001\u7cbe\u5ea6\u304c99.9%\u3067\u3042\u308b\u3053\u3068\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15360\" style=\"width: 542px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15360\" class=\"wp-image-15360\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/15916439a5e45eeeb97bcab9cf9fa611.jpg\" alt=\"\u56f33. \u5272\u308a\u5f53\u3066\u3089\u308c\u305f\u5869\u57fa\u3068\u54c1\u8cea\u30b9\u30b3\u30a2Q\uff08Quality Value: QV\uff09\u306e\u4f8b Sequencing Analysis Software 8 user guide\u3088\u308a\u629c\u7c8b\" width=\"532\" height=\"318\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/15916439a5e45eeeb97bcab9cf9fa611.jpg 1018w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/15916439a5e45eeeb97bcab9cf9fa611-300x179.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/15916439a5e45eeeb97bcab9cf9fa611-768x459.jpg 768w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><p id=\"caption-attachment-15360\" class=\"wp-caption-text\">\u56f33. \u5272\u308a\u5f53\u3066\u3089\u308c\u305f\u5869\u57fa\u3068\u54c1\u8cea\u30b9\u30b3\u30a2Q\uff08Quality Value: QV\uff09\u306e\u4f8b<br \/>Sequencing Analysis Software 8 user guide\u3088\u308a\u629c\u7c8b<\/p><\/div>\n<p>\u7279\u5b9a\u306e\u5869\u57fa\u3084\u9818\u57df\u306b\u4f4e\u3044\u54c1\u8cea\u30b9\u30b3\u30a2\u304c\u5272\u308a\u5f53\u3066\u3089\u308c\u308b\u7406\u7531\u306f\u3055\u307e\u3056\u307e\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001GC\u30ea\u30c3\u30c1\u306a\u9818\u57df\u306f\u3001\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u304c\u3046\u307e\u304f\u8aad\u307f\u9032\u3081\u3089\u308c\u305a\u3001\u30d4\u30fc\u30af\u306e\u5727\u7e2e\u304c\u8d77\u3053\u308a\u307e\u3059\u3002\u56de\u6587\u914d\u5217\u306a\u3069\u4e8c\u6b21\u69cb\u9020\u3092\u5f62\u6210\u3059\u308b\u914d\u5217\u3082\u3001\u3053\u308c\u3089\u306e\u914d\u5217\u4e2d\u306b\u5b58\u5728\u3059\u308b\u5869\u57fa\u306e\u54c1\u8cea\u30b9\u30b3\u30a2\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3057\u307e\u3059\u3002\u4e00\u65b9\u3001\u4f4e\u3044\u54c1\u8cea\u30b9\u30b3\u30a2\uff08\u9ad8\u3044\u30a8\u30e9\u30fc\u78ba\u7387\uff09\u3067\u5869\u57fa\u304c\u30b3\u30fc\u30eb\u3055\u308c\u305f\u5834\u5408\u3001\u300c\u305d\u306e\u5869\u57fa\u304c\u4e0d\u6b63\u78ba\u3067\u3042\u308b\u300d\u3053\u3068\u306e\u4fe1\u983c\u6027\u306f\u9ad8\u3044\u3082\u306e\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<h2>\u76ee\u7684\u306b\u5fdc\u3058\u305f\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/h2>\n<p>\u53d6\u5f97\u3055\u308c\u305f\u5869\u57fa\u914d\u5217\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A38938?SID=srch-hj-A38938?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">Applied Biosystems\u2122 Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/a>\u3092\u4f7f\u7528\u3057\u3066\u95b2\u89a7\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A53552?SID=srch-srp-A53552?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">Applied Biosystems\u2122 Variant Reporter\u2122 \u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/a>\u3067\u306f\u3001\u5869\u57fa\u914d\u5217\u306e\u8868\u793a\u3001\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u914d\u5217\u3068\u306e\u6bd4\u8f03\u3001\u5909\u7570\u306e\u691c\u51fa\u304c\u3067\u304d\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A53548?SID=srch-hj-A53548?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">Applied Biosystems\u2122 SeqScape\u2122 \u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/a>\u3067\u306f\u3001\u3055\u3089\u306b\u3001\u8907\u6570\u306e\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u914d\u5217\u30e9\u30a4\u30d6\u30e9\u30ea\u30fc\u3068\u306e\u6bd4\u8f03\u306a\u3069\u3082\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u3053\u308c\u3089\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u5168\u3066\u4e8b\u524d\u306b\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3067\u304d\u3001\u30c7\u30fc\u30bf\u3092\u8aad\u307f\u8fbc\u307f\u3001\u3044\u304f\u3064\u304b\u306e\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3060\u3051\u3067\u3001\u89e3\u6790\u304c\u5b9f\u884c\u3055\u308c\u3001\u30ec\u30dd\u30fc\u30c8\u304c\u751f\u6210\u3055\u308c\u307e\u3059\u3002\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-dna-sequencing\/sanger-sequencing-data-analysis.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u86cd\u5149\u304c\u691c\u51fa\u3055\u308c\u3001\u5869\u57fa\u306e\u60c5\u5831\u306b\u5909\u63db\u3055\u308c\u308b\u307e\u3067\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308b\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u3064\u3044\u3066\u3001\u3088\u308a\u8a73\u3057\u304f\u77e5\u308a\u305f\u3044\u65b9\u306f\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u672c\u539f\u5247\u3092\u5b66\u3079\u308b\u8cc7\u6599\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3066\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_2_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u305f\u30c7\u30fc\u30bf\u89e3\u6790\u306e\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3082\u3054\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<br \/>\n\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30b3\u30fc\u30b9\uff1a<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/capillary-sequencer-3.html?CID=gsd_cap_sbu_r04_jp_cp1425_pjt7502_gsd00000_0so_blg_op_awa_og_s00_ce_basic_dna_gsd_ts_3_2_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\uff083\uff09\u30c7\u30fc\u30bf\u89e3\u6790\u3000\uff5e\u5909\u7570\u89e3\u6790\u7de8\uff5e<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u3001\u30c7\u30fc\u30bf\u304c\u30a2\u30ca\u30ed\u30b0\u4fe1\u53f7\u304b\u3089\u30c7\u30b8\u30bf\u30eb\u4fe1\u53f7\u306b\u5909\u63db\u3055\u308c\u3001\u54c1\u8cea\u30b9\u30b3\u30a2\u3068\u3068\u3082\u306b\u5869\u57fa\u304c\u5272\u308a\u5f53\u3066\u3089\u308c\u308b\u307e\u3067\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u5909\u63db \u30d6\u30ed\u30b0 \u201c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068 <\/p>\n","protected":false},"author":975,"featured_media":12643,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[183],"division":[],"class_list":["post-15355","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-sanger-seq","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db\" \/>\n<meta property=\"og:description\" content=\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u3001\u30c7\u30fc\u30bf\u304c\u30a2\u30ca\u30ed\u30b0\u4fe1\u53f7\u304b\u3089\u30c7\u30b8\u30bf\u30eb\u4fe1\u53f7\u306b\u5909\u63db\u3055\u308c\u3001\u54c1\u8cea\u30b9\u30b3\u30a2\u3068\u3068\u3082\u306b\u5869\u57fa\u304c\u5272\u308a\u5f53\u3066\u3089\u308c\u308b\u307e\u3067\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u5909\u63db \u30d6\u30ed\u30b0 \u201c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-09-19T06:14:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-18T07:03:45+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"650\" \/>\n\t<meta property=\"og:image:height\" content=\"599\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db\",\"datePublished\":\"2023-09-19T06:14:04+00:00\",\"dateModified\":\"2024-09-18T07:03:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/\"},\"wordCount\":73,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"keywords\":[\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/\",\"name\":\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"datePublished\":\"2023-09-19T06:14:04+00:00\",\"dateModified\":\"2024-09-18T07:03:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/09\\\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\",\"width\":650,\"height\":599,\"caption\":\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/ce_basic_dna_gsd_ts_3-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db","og_description":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u3001\u30c7\u30fc\u30bf\u304c\u30a2\u30ca\u30ed\u30b0\u4fe1\u53f7\u304b\u3089\u30c7\u30b8\u30bf\u30eb\u4fe1\u53f7\u306b\u5909\u63db\u3055\u308c\u3001\u54c1\u8cea\u30b9\u30b3\u30a2\u3068\u3068\u3082\u306b\u5869\u57fa\u304c\u5272\u308a\u5f53\u3066\u3089\u308c\u308b\u307e\u3067\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u5909\u63db \u30d6\u30ed\u30b0 \u201c\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-09-19T06:14:04+00:00","article_modified_time":"2024-09-18T07:03:45+00:00","og_image":[{"width":650,"height":599,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db","datePublished":"2023-09-19T06:14:04+00:00","dateModified":"2024-09-18T07:03:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/"},"wordCount":73,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","keywords":["\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/","name":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","datePublished":"2023-09-19T06:14:04+00:00","dateModified":"2024-09-18T07:03:45+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","width":650,"height":599,"caption":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_basic_dna_gsd_ts_3-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u3053\u3068\uff1a\u3000\u5149\u4fe1\u53f7\u304b\u3089\u5869\u57fa\u3078\u306e\u60c5\u5831\u5909\u63db"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":183,"label":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg",650,599,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":183,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","slug":"sanger-seq","term_group":0,"term_taxonomy_id":183,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/09\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15355","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=15355"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15355\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/12643"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=15355"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=15355"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=15355"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=15355"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}