{"id":15396,"date":"2023-09-26T16:08:19","date_gmt":"2023-09-26T07:08:19","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=15396"},"modified":"2025-08-12T17:06:01","modified_gmt":"2025-08-12T08:06:01","slug":"western-blot-protein-ts-6","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/","title":{"rendered":"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13122\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg\" alt=\"westernblotting\" width=\"761\" height=\"476\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg 761w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western-300x188.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western-320x200.jpg 320w\" sizes=\"auto, (max-width: 761px) 100vw, 761px\" \/><br \/>\n\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u300c\u9078\u3073\u65b9\u300d\u306b\u3064\u3044\u3066\u9023\u8f09\u3057\u3066\u3044\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u3001<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-5\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u524d\u56de<\/a>\u306f\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306e\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u3001\u3064\u307e\u308a\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002<br \/>\n\u3053\u3053\u3067\u306f\u3001\u6297\u4f53\u3092\u9078\u3076\u3068\u304d\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30dd\u30a4\u30f3\u30c8\u306b\u3064\u3044\u3066\u3001\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u4e00\u6b21\u6297\u4f53\u9078\u629e\u6642\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068<\/h2>\n<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f\u3001\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3092\u7d42\u3048\u305f\u5f8c\u3001\u4e00\u6b21\u6297\u4f53\u3067\u30bf\u30fc\u30b2\u30c3\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u7279\u7570\u7684\u306b\u8a8d\u8b58\u3055\u305b\u3001\u9175\u7d20\u3084\u86cd\u5149\u6a19\u8b58\u3055\u308c\u3066\u3044\u308b\u4e8c\u6b21\u6297\u4f53\u3092\u4e00\u6b21\u6297\u4f53\u306b\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u86cd\u5149\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306e\u5834\u5408\u306f\u691c\u51fa\u30b9\u30c6\u30c3\u30d7\u306b\u79fb\u308a\u3001\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306e\u5834\u5408\u306f\u3001\u5316\u5b66\u767a\u5149\u3084\u767a\u8272\u306a\u3069\u306e\u57fa\u8cea\u3092\u9175\u7d20\u306b\u53cd\u5fdc\u3055\u305b\u3066\u3001\u691c\u51fa\u3092\u884c\u3044\u307e\u3059\u3002\u3053\u3053\u307e\u3067\u306e\u6d41\u308c\u3092\u7d42\u3048\u305f\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u72b6\u614b\u3092\u3001\u56f31\u306b\u793a\u3057\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_15401\" style=\"width: 628px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15401\" class=\"size-full wp-image-15401\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-01.jpg\" alt=\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0 \u4e8c\u6b21\u6297\u4f53\u53cd\u5fdc\u7d42\u4e86\u5f8c\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u72b6\u614b\" width=\"618\" height=\"220\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-01.jpg 618w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-01-300x107.jpg 300w\" sizes=\"auto, (max-width: 618px) 100vw, 618px\" \/><p id=\"caption-attachment-15401\" class=\"wp-caption-text\">\u56f31\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0 \u4e8c\u6b21\u6297\u4f53\u53cd\u5fdc\u7d42\u4e86\u5f8c\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u72b6\u614b<\/p><\/div>\n<p>\u672c\u30d6\u30ed\u30b0\u3067\u30af\u30ed\u30fc\u30ba\u30a2\u30c3\u30d7\u3059\u308b\u306e\u306f\u3001\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u7d50\u5408\u3059\u308b\u4e00\u6b21\u6297\u4f53\u3068\u3001\u9175\u7d20\u3084\u86cd\u5149\u8272\u7d20\u306a\u3069\u304c\u6a19\u8b58\u3055\u308c\u305f\u4e8c\u6b21\u6297\u4f53\u306b\u3064\u3044\u3066\u3067\u3059\u3002<\/p>\n<p>\u6297\u4f53\u3092\u81ea\u4f5c\u3059\u308b\u306e\u306f\u5927\u5909\u306a\u306e\u3067\u3001\u5e02\u8ca9\u54c1\u3092\u7528\u610f\u3055\u308c\u3066\u3044\u308b\u4eba\u304c\u307b\u3068\u3093\u3069\u3067\u3057\u3087\u3046\u3002\u3057\u304b\u3057\u30e1\u30fc\u30ab\u30fc\u306e\u30b5\u30a4\u30c8\u3067\u4e00\u6b21\u6297\u4f53\u3084\u4e8c\u6b21\u6297\u4f53\u3092\u691c\u7d22\u3057\u3066\u307f\u308b\u3068\u3001\u8907\u6570\u30d2\u30c3\u30c8\u3057\u3066\u3057\u307e\u3044\u3001\u3069\u308c\u304c\u826f\u3044\u306e\u304b\u308f\u304b\u3089\u306a\u3044\u3053\u3068\u3082\u591a\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<p>\u305d\u3046\u3044\u3046\u3068\u304d\u306e\u305f\u3081\u306b\u3001\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001\u300c\u6297\u4f53\u9078\u629e\u6642\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\u300d\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002<\/p>\n<h3><u>\u30e2\u30ce\u30af\u30ed\u3068\u30dd\u30ea\u30af\u30ed<\/u><\/h3>\n<p>\u4e00\u6b21\u6297\u4f53\u306b\u306f\u3001\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u3068\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u304c\u3042\u308a\u307e\u3059\u3002\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u306f\u3001\u6297\u539f\u3092\u6ce8\u5c04\u3057\u305f\u52d5\u7269\u304b\u3089\u3001\u6297\u4f53\u3092\u7523\u751f\u3059\u308bB\u7d30\u80de\u3092\u5358\u96e2\u3057\u3066\u3001\u30df\u30a8\u30ed\u30fc\u30de\u3068\u3044\u3046\u57f9\u990a\u7d30\u80de\u3068\u878d\u5408\u3055\u305b\u3066\u6297\u4f53\u3092\u4f5c\u88fd\u3057\u305f\u3082\u306e\u3067\u3001\u5358\u4e00\uff08\u30e2\u30ce\uff09\u306e\u30a8\u30d4\u30c8\u30fc\u30d7\u90e8\u4f4d\u3092\u8a8d\u8b58\u3059\u308b\u6297\u4f53\u3067\u3059\u3002\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u306f\u3001\u52d5\u7269\u306b\u6297\u539f\u3092\u8907\u6570\u56de\u6ce8\u5c04\u3057\u305f\u5f8c\u3001\u8840\u6db2\u3092\u63a1\u53d6\u3057\u3001\u305d\u306e\u8840\u6e05\u304b\u3089\u6297\u4f53\u3092\u7cbe\u88fd\u3057\u305f\u3082\u306e\u3067\u3001\u305d\u308c\u305e\u308c\u7570\u306a\u308b\u30a8\u30d4\u30c8\u30fc\u30d7\u90e8\u4f4d\u3092\u8a8d\u8b58\u3059\u308b\u8907\u6570\uff08\u30dd\u30ea\uff09\u306e\u6297\u4f53\u306e\u6df7\u5408\u7269\u3067\u3059\u3002<\/p>\n<div id=\"attachment_15399\" style=\"width: 507px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15399\" class=\"size-full wp-image-15399\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-02.jpg\" alt=\"\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u3068\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\" width=\"497\" height=\"204\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-02.jpg 497w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-02-300x123.jpg 300w\" sizes=\"auto, (max-width: 497px) 100vw, 497px\" \/><p id=\"caption-attachment-15399\" class=\"wp-caption-text\">\u56f32\uff1a\u30e2\u30ce\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3068\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53<\/p><\/div>\n<p>\u3067\u306f\u3001\u3053\u308c\u3089\u306e\u9078\u629e\u306b\u3088\u3063\u3066\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f\u3069\u3046\u3044\u3046\u9055\u3044\u304c\u3082\u305f\u3089\u3055\u308c\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u4e21\u8005\u3092\u300c\u975e\u7279\u7570\u53cd\u5fdc\u300d\u3068\u300c\u691c\u51fa\u611f\u5ea6\u300d\u306b\u304a\u3044\u3066\u6bd4\u8f03\u3059\u308b\u3068\u3001\u6b21\u306e\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p><b>\u25c6\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u975e\u7279\u7570\u7684\u53cd\u5fdc\u306e\u8d77\u3053\u308a\u306b\u304f\u3055\u25c6<\/b><br \/>\n<b>\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u3000\uff1e\u3000\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53<\/b><\/p>\n<p><b>\u25c6\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u4e00\u822c\u7684\u306a\u691c\u51fa\u611f\u5ea6\u25c6<\/b><br \/>\n<b>\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3000\uff1e\u3000\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53<\/b><\/p>\n<p>\u975e\u7279\u7570\u53cd\u5fdc\u3068\u691c\u51fa\u611f\u5ea6\u3001\u3069\u3061\u3089\u3082\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f\u91cd\u8981\u306a\u8981\u7d20\u3067\u3059\u304c\u3001\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u3068\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3067\u306f\u3001\u76f8\u53cd\u3059\u308b\u6027\u8cea\u3092\u6301\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3082\u3046\u5c11\u3057\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3057\u3087\u3046\u3002<br \/>\n\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u306e\u4ea4\u5dee\u6027\u304c\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u3088\u308a\u5927\u304d\u3044\u306e\u306f\u3001\u8907\u6570\u306e\u6297\u4f53\u306e\u30d7\u30fc\u30eb\u3067\u3059\u306e\u3067\u3001\u4e00\u822c\u7684\u306a\u50be\u5411\u3068\u3057\u3066\u3001\u76f8\u5bfe\u7684\u306b\u975e\u7279\u7570\u53cd\u5fdc\u3092\u6301\u3064\u6297\u4f53\u3092\u542b\u3080\u30ea\u30b9\u30af\u304c\u9ad8\u3044\u305f\u3081\u3067\u3059\u3002\u3057\u304b\u3057\u30011\u3064\u306e\u6297\u539f\u306b\u8907\u6570\u306e\u6297\u4f53\u304c\u7d50\u5408\u3067\u304d\u308b\u306e\u3067\u3001\u4e8c\u6b21\u6297\u4f53\u3082\u8907\u6570\u7d50\u5408\u3067\u304d\u307e\u3059\u3002\u305d\u308c\u3086\u3048\u306b\u3001\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3067\u306f\u3001\u975e\u7279\u7570\u7684\u53cd\u5fdc\u306e\u30ea\u30b9\u30af\u306f\u6bd4\u8f03\u7684\u9ad8\u304f\u306a\u308b\u3082\u306e\u306e\u3001\u691c\u51fa\u611f\u5ea6\u306f\u9ad8\u304f\u306a\u308a\u3084\u3059\u3044\u50be\u5411\u306b\u3042\u308a\u307e\u3059\u3002\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u306f\u3053\u308c\u306e\u9006\u3067\u3001\u975e\u7279\u7570\u7684\u53cd\u5fdc\u306f\u4f4e\u3044\u3067\u3059\u304c\u3001\u691c\u51fa\u611f\u5ea6\u306f\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3068\u6bd4\u3079\u308b\u3068\u4f4e\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u7279\u6027\u3092\u8003\u3048\u3066\u3001\u3069\u3061\u3089\u3092\u9078\u3076\u306e\u304b\u3092\u6c7a\u3081\u307e\u3057\u3087\u3046\u3002<\/p>\n<h3><u>\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u78ba\u8a8d\u306f\u5fc5\u9808<\/u><\/h3>\n<p>\u591a\u304f\u306e\u6297\u4f53\u30e1\u30fc\u30ab\u30fc\u3067\u306f\u3001\u305d\u306e\u4e00\u6b21\u6297\u4f53\u304c\u3069\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9069\u3057\u3066\u3044\u308b\u304b\u66f8\u304b\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u5185\u5bb9\u306f\u6297\u4f53\u9078\u629e\u6642\u306b\u5fc5\u305a\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002<br \/>\n\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u78ba\u8a8d\u304c\u5fc5\u9808\u306a\u306e\u306f\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u3063\u3066\u6297\u539f\u306e\u72b6\u614b\u304c\u7570\u306a\u308b\u305f\u3081\u3067\u3059\u3002\u4f8b\u3048\u3070ELISA\u3084\u514d\u75ab\u67d3\u8272\u3067\u306f\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5f62\u304c\u4fdd\u305f\u308c\u305f\u6297\u539f\u3092\u3001\u6297\u4f53\u304c\u8a8d\u8b58\u3057\u307e\u3059\u3002\u4e00\u65b9\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f\u3001SDS\u306b\u3088\u3063\u3066\u5909\u6027\u3057\u3001DTT\u306b\u3088\u3063\u3066\u9084\u5143\u51e6\u7406\u3055\u308c\u305f\u6297\u539f\u3092\u3001\u6297\u4f53\u304c\u8a8d\u8b58\u3057\u306a\u304f\u3066\u306f\u306a\u308a\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u4f8b\u3048\u3070ELISA\u3067\u78ba\u8a8d\u6e08\u307f\u306e\u6297\u4f53\u3067\u306f\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u6297\u539f\u3092\u691c\u51fa\u3067\u304d\u306a\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u6b21\u6297\u4f53\u3092\u9078\u3076\u3068\u304d\u306f\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u6b04\u3092\u3057\u3063\u304b\u308a\u78ba\u8a8d\u3057\u3066\u304a\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n<h3><u>\u7279\u7570\u6027\u691c\u8a3c\u6e08\u307f\u306e\u4e00\u6b21\u6297\u4f53\u3082<\/u><\/h3>\n<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u7121\u4e8b\u306b\u691c\u51fa\u3067\u304d\u305f\u3051\u308c\u3069\u3001\u679c\u305f\u3057\u3066\u3053\u306e\u30d0\u30f3\u30c9\u306f\u672c\u5f53\u306b\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u3060\u308d\u3046\u304b\uff1f\u305d\u3093\u306a\u7591\u554f\u3068\u5411\u304d\u5408\u3063\u305f\u7d4c\u9a13\u304c\u3042\u308b\u65b9\u3082\u3044\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u6297\u4f53\u306e\u7279\u7570\u6027\u3084\u6027\u80fd\u306b\u3064\u3044\u3066\u5b9f\u969b\u306b\u691c\u8a3c\u3055\u308c\u305f\u6297\u4f53\u3092\u4f7f\u3044\u305f\u3044\u3068\u3044\u3046\u7814\u7a76\u8005\u306f\u591a\u304f\u3044\u3089\u3063\u3057\u3083\u3044\u307e\u3059\u3002\u3053\u3046\u3044\u3063\u305f\u80cc\u666f\u304b\u3089\u3001\u6297\u4f53\u304c\u6b63\u3057\u304f\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u7d50\u5408\u3057\u305f\u3053\u3068\u3092\u8a3c\u660e\u3057\u305f\u300c\u691c\u8a3c\u6e08\u307f\u306e\u6297\u4f53\u300d\u3068\u3044\u3046\u3082\u306e\u304c\u5b58\u5728\u3057\u307e\u3059\u3002<\/p>\n<p>\u30e1\u30fc\u30ab\u30fc\u306b\u3088\u3063\u3066\u547c\u3073\u540d\u306f\u7570\u306a\u308a\u307e\u3059\u304c\u3001\u305f\u3068\u3048\u3070\u3001\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u3067\u306f\u3001\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/antibodies\/invitrogen-antibody-validation.html?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">Advanced Verification<\/a>\u300d\u3068\u3044\u3046\u30a2\u30a4\u30b3\u30f3\u304c\u3064\u3044\u3066\u3044\u307e\u3059\u3002\u30ce\u30c3\u30af\u30c0\u30a6\u30f3\u30fb\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u30fb\u4e2d\u548c\u30fbIP\u3068\u8cea\u91cf\u5206\u6790\u6cd5\u306a\u3069\u3001\u898f\u5b9a\u3055\u308c\u305f\u8907\u6570\u306e\u691c\u8a3c\u65b9\u6cd5\u306e\u3046\u3061\u5c11\u306a\u304f\u3068\u30821\u7a2e\u985e\u4ee5\u4e0a\u306e\u691c\u8a3c\u3092\u5b9f\u65bd\u3057\u3066\u3044\u308b\u6297\u4f53\u3067\u3059\u3002\u4f8b\u3048\u3070\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u691c\u8a3c\u3067\u306f\u3001CRISPR\/Cas9\u3092\u7528\u3044\u3066\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u30ce\u30c3\u30af\u30a2\u30a6\u30c8\u682a\u3092\u7528\u3044\u3066\u8a55\u4fa1\u3092\u3057\u3066\u3044\u307e\u3059\u3002\u3082\u3057\u6297\u4f53\u306e\u7279\u7570\u6027\u306b\u4e0d\u5b89\u304c\u3042\u308b\u5834\u5408\u306f\u3001\u3053\u3046\u3044\u3063\u305f\u691c\u8a3c\u6e08\u307f\u306e\u6297\u4f53\u3092\u9078\u629e\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n<h2>\u4e8c\u6b21\u6297\u4f53\u9078\u629e\u6642\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068<\/h2>\n<p>\u307e\u305a\u3001\u57fa\u672c\u3068\u3057\u3066\u3001\u4e8c\u6b21\u6297\u4f53\u306f\u3001\u4e00\u6b21\u6297\u4f53\u306eHost\uff08\u7531\u6765\u30fb\u514d\u75ab\u52d5\u7269\uff09\u306b\u5fdc\u3058\u3066\u9078\u3073\u307e\u3057\u3087\u3046\u3002\u4f8b\u3048\u3070\u4e00\u6b21\u6297\u4f53\u306eHost\u304cmouse\u3067\u3042\u308c\u3070\u3001\u4e8c\u6b21\u6297\u4f53\u306fAnti-Mouse\u3092\u9078\u629e\u3057\u307e\u3059\u3002<\/p>\n<p>\u4e8c\u6b21\u6297\u4f53\u3067\u306f\u3001\u4f55\u3089\u304b\u306e\u6a19\u8b58\u304c\u3042\u308b\u3082\u306e\u3092\u7528\u3044\u308b\u3053\u3068\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u86cd\u5149\u691c\u51fa\u3067\u3042\u308c\u3070\u3001\u86cd\u5149\u6a19\u8b58\u306e\u4e8c\u6b21\u6297\u4f53\u3001\u5316\u5b66\u767a\u5149\u3067\u691c\u51fa\u3059\u308b\u306e\u3067\u3042\u308c\u3070\u3001HRP\u306a\u3069\u306e\u9175\u7d20\u6a19\u8b58\u306e\u3082\u306e\u3092\u7528\u3044\u307e\u3059\u3002<br \/>\n\u307e\u305f\u3001\u66f8\u304b\u308c\u3066\u3044\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u307b\u3068\u3093\u3069\u306e\u4e8c\u6b21\u6297\u4f53\u306f\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u3067\u3059\u306e\u3067\u3001\u30e2\u30ce\u30af\u30ed\u3068\u30dd\u30ea\u30af\u30ed\u3067\u60a9\u3080\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u3067\u306f\u3001\u4e8c\u6b21\u6297\u4f53\u3067\u306f\u3069\u3046\u3044\u3063\u305f\u70b9\u3092\u30dd\u30a4\u30f3\u30c8\u306b\u9078\u3093\u3067\u3044\u3051\u3070\u3088\u3044\u306e\u304b\u3001\u304a\u8a71\u3092\u7d9a\u3051\u307e\u3057\u3087\u3046\u3002<\/p>\n<h3><u>Whole\u3068F(ab&#8217;)2<\/u><\/h3>\n<p>\u4e8c\u6b21\u6297\u4f53\u3092\u63a2\u3057\u3066\u3044\u308b\u3068\u3001\u300cWhole\u300d\u30bf\u30a4\u30d7\u3068\u300cF(ab&#8217;)2\u300d\u30bf\u30a4\u30d7\u3068\u3044\u3046\u3082\u306e\u3092\u898b\u304b\u3051\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002F(ab&#8217;)2\u306f\u3001Whole\uff08\u5b8c\u5168\u9577\uff09\u306e\u6297\u4f53\u3092\u30da\u30d7\u30b7\u30f3\u3067\u6d88\u5316\u3057\u305f\u6297\u4f53\u3067\u3059\u3002\u8a00\u3044\u63db\u3048\u308b\u3068\u3001\u6297\u4f53\u306eFc\u90e8\u5206\u3092\u6301\u305f\u306a\u3044\u6297\u4f53\u306e\u3053\u3068\u3067\u3059\u3002\u56f33\u3092\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<div id=\"attachment_15400\" style=\"width: 412px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15400\" class=\"size-full wp-image-15400\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-03.png\" alt=\"\u6297\u4f53\u65ad\u7247\u306e\u540d\u79f0\" width=\"402\" height=\"125\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-03.png 402w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-03-300x93.png 300w\" sizes=\"auto, (max-width: 402px) 100vw, 402px\" \/><p id=\"caption-attachment-15400\" class=\"wp-caption-text\">\u56f33\uff1a \u6297\u4f53\u65ad\u7247\u306e\u540d\u79f0<\/p><\/div>\n<p>\u307e\u305a\u3001\u6297\u4f53\u306e\u6297\u539f\u8a8d\u8b58\u90e8\u4f4d\u306fF(ab&#8217;)2\u306b\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u6297\u539f\u3078\u306e\u7d50\u5408\u6027\u306fWhole\u3082F(ab&#8217;)2\u3082\u5909\u308f\u308a\u307e\u305b\u3093\u3002\u4e00\u65b9\u3001F(ab&#8217;)2\u306b\u306f\u3001Fc\u53d7\u5bb9\u4f53\u306b\u7d50\u5408\u3059\u308bFc\u90e8\u5206\u304c\u306a\u3044\u305f\u3081\u3001\u539f\u7406\u7684\u306b\u306f\u975e\u7279\u7570\u7684\u7d50\u5408\u3092\u6291\u3048\u3089\u308c\u308b\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306fWhole\u3067\u3082F(ab&#8217;)2\u3067\u3082\u3042\u307e\u308a\u9055\u3044\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3042\u308c\u3070\u3069\u3061\u3089\u3092\u4f7f\u3063\u3066\u3082\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002<br \/>\n\u306a\u304a\u3001Protein A\u3084Protein G\u306fFc\u306b\u7d50\u5408\u3057\u307e\u3059\u306e\u3067\u3001Protein A\u3084Protein G\u3092\u7528\u3044\u305f\u514d\u75ab\u6c88\u964d\u3067\u306f\u3001F(ab&#8217;)2\u6297\u4f53\u3092\u4f7f\u308f\u306a\u3044\u3088\u3046\u306b\u6ce8\u610f\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n<h3><u>Cross-Adsorbed\u30bf\u30a4\u30d7\u3068\u306f\uff1f<\/u><\/h3>\n<p>Cross-Adsorbed\u3068\u306f\u3001\u65e5\u672c\u8a9e\u306b\u76f4\u3059\u3068\u300c\u4ea4\u5dee-\u5438\u7740\u3057\u305f\u300d\u6297\u4f53\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u4ea4\u5dee\u53cd\u5fdc\u3092\u8d77\u3053\u3057\u305f\u304f\u306a\u3044\u52d5\u7269\u7a2e\u306e\u6297\u4f53\u3092\u3001\u3042\u3089\u304b\u3058\u3081\u30ab\u30e9\u30e0\u306a\u3069\u306b\u5438\u7740\u3055\u305b\u3001\u53d6\u308a\u9664\u3044\u305f\u6297\u4f53\u3068\u3044\u3046\u610f\u5473\u3067\u3059\u3002<\/p>\n<p>\u4f8b\u3092\u51fa\u3057\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002Invitrogen\u2122 <a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Goat-anti-Rabbit-IgG-H-L-Cross-Adsorbed-Secondary-Antibody-Polyclonal\/G-21234?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">Goat anti-Rabbit IgG (H+L) Cross-Adsorbed Secondary Antibody, HRP<\/a>\u306f\u3001rabbit\u306b\u5bfe\u3059\u308b\u6297\u4f53\u3067\u3059\u304c\u3001human IgG\u3001human serum\u3001mouse IgG\u3001mouse serum\u3001bovine serum\u3092\u30ea\u30ac\u30f3\u30c9\u3068\u3057\u3066\u56fa\u5b9a\u5316\u3057\u305f\u30ec\u30b8\u30f3\u3092\u7528\u3044\u3001\u3053\u308c\u3089\u306b\u53cd\u5fdc\u3059\u308b\u6297\u4f53\u3092\u9664\u53bb\u3057\u305f\u300cCross-Absorbed\u300d\u30bf\u30a4\u30d7\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3053\u306e\u6297\u4f53\u306f\u3001human IgG\u3001human serum\u3001mouse IgG\u3001mouse serum\u3001bovine serum\u3078\u306e\u4ea4\u5dee\u6027\u3092\u6301\u305f\u306a\u3044\u6297\u4f53\u3068\u8a00\u3048\u307e\u3059\u3002<\/p>\n<p>Cross-Adsorbed\u30bf\u30a4\u30d7\u306e\u6297\u4f53\u3068\u3057\u3066\u9069\u5207\u306a\u3082\u306e\u3092\u9078\u3079\u3070\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u5185\u5728\u6027IgG\u3078\u306e\u53cd\u5fdc\u3092\u9632\u3050\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u4f8b\u3048\u30701\u679a\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u3067\u8907\u6570\u306e\u30d0\u30f3\u30c9\u3092\u591a\u91cd\u691c\u51fa\u3059\u308b\u969b\u3001\u7570\u306a\u308b\u52d5\u7269\u7a2e\u7531\u6765\u306e\u4e00\u6b21\u6297\u4f53\u3092\u7528\u3044\u308b\u30b1\u30fc\u30b9\u3067\u3082\u3001\u5b89\u5fc3\u3057\u3066\u4f7f\u7528\u3067\u304d\u307e\u3059\uff08\u86cd\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u591a\u91cd\u67d3\u8272\u306b\u3064\u3044\u3066\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-assays-analysis\/western-blotting\/detect-proteins-western-blot\/fluorescent-western-blot-detection.html?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\uff09\u3002<\/p>\n<p>\u307e\u305f\u3001\u4e8c\u6b21\u6297\u4f53\u3082\u3001\u540c\u69d8\u306b\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3068\u3057\u3066\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u78ba\u8a8d\u6e08\u307f\u306e\u3082\u306e\u3092\u4f7f\u7528\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n<h2>\u6297\u4f53\u5e0c\u91c8\u6db2\u3068\u6fc3\u5ea6<\/h2>\n<p>\u3055\u3066\u3001\u6297\u4f53\u304c\u6c7a\u307e\u3063\u305f\u3089\u3001\u6297\u4f53\u3092\u5e0c\u91c8\u3059\u308b\u6db2\u3092\u7528\u610f\u3057\u307e\u3057\u3087\u3046\u3002\u88681\u306b\u793a\u3057\u305f3\u7a2e\u985e\u306e\u6eb6\u6db2\u304c\u3001\u4e00\u6b21\u6297\u4f53\u3084\u4e8c\u6b21\u6297\u4f53\u306e\u5e0c\u91c8\u6db2\u3068\u3057\u3066\u3088\u304f\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88681. \u6297\u4f53\u306e\u5e0c\u91c8\u6db2<\/caption>\n<tbody>\n<tr>\n<td width=\"132\">\u6297\u4f53\u5e0c\u91c8\u6db2<\/td>\n<td width=\"454\">\u5185\u5bb9<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">TBS-T<\/td>\n<td width=\"454\">TBS\u306b0.1%\u306eTween 20\u3092\u52a0\u3048\u305f\u3082\u306e<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">PBS-T<\/td>\n<td width=\"454\">PBS\u306b0.1%\u306eTween 20\u3092\u52a0\u3048\u305f\u3082\u306e<br \/>\n\u203b\u30ea\u30f3\u9178\u5316\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u691c\u51fa\u306b\u306f\u4f7f\u7528\u3067\u304d\u306a\u3044<\/td>\n<\/tr>\n<tr>\n<td width=\"132\">\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u8a66\u85ac<\/td>\n<td width=\"454\">\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u524d\u306e\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306b\u7528\u3044\u305f\u8a66\u85ac<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>TBS-T\u307e\u305f\u306fPBS-T\u306bTween\u2122 20\u3092\u52a0\u3048\u308b\u3053\u3068\u3067\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306e\u6297\u539f\u4ee5\u5916\u306e\u90e8\u5206\u306b\u6297\u4f53\u304c\u7d50\u5408\u3059\u308b\u306e\u3092\u6291\u3048\u308b\u3001\u3064\u307e\u308a\u975e\u7279\u7570\u7684\u53cd\u5fdc\u3092\u6291\u3048\u308b\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\u307e\u305f\u3001\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u8a66\u85ac\u3067\u6297\u4f53\u3092\u5e0c\u91c8\u3059\u308b\u3053\u3068\u3067\u3001\u6297\u4f53\u53cd\u5fdc\u3092\u884c\u3044\u306a\u304c\u3089\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3082\u5b9f\u65bd\u3057\u3001\u3053\u3061\u3089\u3082\u975e\u7279\u7570\u7684\u53cd\u5fdc\u3092\u8efd\u6e1b\u3055\u305b\u308b\u52b9\u679c\u304c\u3042\u308a\u307e\u3059\uff08\u6297\u4f53\u5e0c\u91c8\u6db2\u306b\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u8a66\u85ac\u3092\u4f7f\u3046\u3068\u304d\u3082\u3001\u8ee2\u5199\u5f8c\u306e\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30b9\u30c6\u30c3\u30d7\u306f\u5fc5\u9808\u3067\u3059\uff09\u3002\u3057\u304b\u3057\u3001\u6297\u4f53\u5e0c\u91c8\u6db2\u3078\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u8a66\u85ac\u3084\u754c\u9762\u6d3b\u6027\u5264\u3092\u6dfb\u52a0\u3057\u3059\u304e\u308b\u3068\u3001\u6297\u4f53\u306e\u6297\u539f\u3078\u306e\u7d50\u5408\u3082\u6291\u3048\u3089\u308c\u3066\u3057\u307e\u3044\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u30b7\u30b0\u30ca\u30eb\u4f4e\u6e1b\u306b\u7d50\u3073\u3064\u304f\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u4e07\u80fd\u306a\u65b9\u6cd5\u3067\u306f\u306a\u3044\u3053\u3068\u306b\u6ce8\u610f\u3057\u307e\u3057\u3087\u3046\u3002\u307e\u305a\u306f\u4e0a\u8ff0\u306e\u3044\u305a\u308c\u304b\u3067\u5b9f\u65bd\u3057\u3001\u7d50\u679c\u3092\u898b\u3066\u307f\u308b\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\u3002<\/p>\n<p>\u6b21\u306b\u3001\u6297\u4f53\u306e\u5e0c\u91c8\u6fc3\u5ea6\u3067\u3059\u3002<\/p>\n<p>\u305f\u3044\u3066\u3044\u306e\u4e00\u6b21\u6297\u4f53\u3084\u4e8c\u6b21\u6297\u4f53\u306b\u306f\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u5e0c\u91c8\u500d\u7387\u306e\u76ee\u5b89\u304c\u66f8\u304b\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001<b><u>\u6297\u4f53\u63a8\u5968\u306e\u5e0c\u91c8\u500d\u7387\u3067\u306f\u306a\u304f\u3001\u691c\u51fa\u8a66\u85ac\u63a8\u5968\u306e\u5e0c\u91c8\u500d\u7387\u306b\u6cbf\u3046\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\u3002<\/u><\/b><br \/>\n\u3053\u308c\u306f\u3001\u6297\u4f53\u306e\u63a8\u5968\u5e0c\u91c8\u500d\u7387\u306f\u3001\u691c\u51fa\u8a66\u85ac\u306e\u611f\u5ea6\u3092\u8003\u616e\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u591a\u3044\u305f\u3081\u3067\u3059\u3002\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f\u3001\u691c\u51fa\u611f\u5ea6\u306f\u691c\u51fa\u8a66\u85ac\u306b\u3088\u3063\u3066\u5927\u304d\u304f\u5909\u308f\u308a\u307e\u3059\u3002\u691c\u51fa\u611f\u5ea6\u304c\u9ad8\u3044\u306e\u306b\u6297\u4f53\u6fc3\u5ea6\u304c\u9ad8\u3059\u304e\u308b\u3068\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u771f\u3063\u9ed2\u306b\u306a\u3063\u305f\u308a\u3001\u9006\u306b\u691c\u51fa\u611f\u5ea6\u304c\u4f4e\u3044\u306e\u306b\u6297\u4f53\u6fc3\u5ea6\u304c\u4f4e\u3059\u304e\u308b\u3068\u30d0\u30f3\u30c9\u304c\u691c\u51fa\u3055\u308c\u306a\u304b\u3063\u305f\u308a\u3057\u307e\u3059\u3002<\/p>\n<p>\u4f8b\u3068\u3057\u3066\u3001\u5b9f\u969b\u306e\u88fd\u54c1\u306e\u60c5\u5831\u3092\u898b\u306a\u304c\u3089\u89e3\u8aac\u3057\u307e\u3057\u3087\u3046\u3002\u4e0b\u8868\u306f\u3001\u4e8c\u6b21\u6297\u4f53\u3067\u3042\u308bInvitrogen\u2122 <a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Goat-anti-Rabbit-IgG-H-L-Secondary-Antibody-Polyclonal\/65-6120?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">Goat anti-Rabbit IgG (H+L) Secondary Antibody, HRP<\/a>\u306e\u63a8\u5968\u5e0c\u91c8\u500d\u7387\u3067\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-15403\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-04.jpg\" alt=\"\" width=\"789\" height=\"121\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-04.jpg 789w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-04-300x46.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-04-768x118.jpg 768w\" sizes=\"auto, (max-width: 789px) 100vw, 789px\" \/><br \/>\n\u3064\u307e\u308a\u3001\u3053\u306e\u6297\u4f53\u306e\u60c5\u5831\u3068\u3057\u3066\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f3,000\u500d\u304b\u308910,000\u500d\u5e0c\u91c8\u3057\u3066\u304f\u3060\u3055\u3044\u3068\u66f8\u304b\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u4e00\u65b9\u3001\u691c\u51fa\u8a66\u85ac\u306b\u66f8\u304b\u308c\u3066\u3044\u308b\u4e8c\u6b21\u6297\u4f53\u306e\u5e0c\u91c8\u500d\u7387\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n<table>\n<caption>\u88682. \u691c\u51fa\u8a66\u85ac\u3054\u3068\u306e\u6297\u4f53\u5e0c\u91c8\u500d\u7387<\/caption>\n<tbody>\n<tr>\n<td width=\"104\">\u901a\u79f0<\/td>\n<td width=\"216\">\u88fd\u54c1\u30ea\u30f3\u30af<\/td>\n<td width=\"105\">\u4e00\u6b21\u6297\u4f53<\/td>\n<td width=\"170\">\u4e8c\u6b21\u6297\u4f53<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">West Atto<\/td>\n<td width=\"216\">Thermo Scientific\u2122<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A38555?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">SuperSignal\u2122 West Atto Ultimate Sensitivity Substrate<\/a><\/td>\n<td width=\"105\">1:5,000<\/td>\n<td width=\"170\">1:100,000 \uff5e 1:250,000<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">West Femto<\/td>\n<td width=\"216\">Thermo Scientific\u2122<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/34095?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">SuperSignal\u2122 West Femto Maximum Sensitivity Substrate<\/a><\/td>\n<td width=\"105\">1:5,000<\/td>\n<td width=\"170\">1:100,000 \uff5e 1:500,000<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">West Dura<\/td>\n<td width=\"216\">Thermo Scientific\u2122<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/34075?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">SuperSignal\u2122 West Dura Extended Duration Substrate<\/a><\/td>\n<td width=\"105\">1:5,000<\/td>\n<td width=\"170\">1:50,000 \uff5e 1:250,000<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">West Pico PLUS<\/td>\n<td width=\"216\">Thermo Scientific\u2122<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/34577?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">SuperSignal\u2122 West Pico PLUS Chemiluminescent Substrate<\/a><\/td>\n<td width=\"105\">1:1,000<\/td>\n<td width=\"170\">1:20,000 \uff5e 1:100,000<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">Pierce ECL Plus<\/td>\n<td width=\"216\">Thermo Scientific\u2122<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/32132?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">Pierce\u2122 ECL Plus Western Blotting Substrate<\/a><\/td>\n<td width=\"105\">1:1,000<\/td>\n<td width=\"170\">1:25,000 \uff5e 1:200,000<\/td>\n<\/tr>\n<tr>\n<td width=\"104\">Pierce ECL<\/td>\n<td width=\"216\">Thermo Scientific\u2122<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/32209?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">Pierce\u2122 ECL Western Blotting Substrate<\/a><\/td>\n<td width=\"105\">1:1,000<\/td>\n<td width=\"170\">1:1,000 \uff5e 1:15,000<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u88682\u3092\u898b\u308b\u3068\u3001\u691c\u51fa\u8a66\u85ac\u306b\u3088\u3063\u3066\u6297\u4f53\u306e\u5e0c\u91c8\u500d\u7387\u304c\u5927\u304d\u304f\u7570\u306a\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/antibody\/product\/Goat-anti-Rabbit-IgG-H-L-Secondary-Antibody-Polyclonal\/65-6120?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">Goat anti-Rabbit IgG (H+L) Secondary Antibody, HRP<\/a>\u3092\u4f7f\u7528\u3059\u308b\u3068\u304d\u3001\u3053\u306e\u6297\u4f53\u306b\u66f8\u304b\u308c\u3066\u3044\u308b\u5e0c\u91c8\u500d\u73873,000\uff5e10,000\u500d\u3092\u4fe1\u3058\u3066\u3001\u4f8b\u3048\u3070West Atto\u3067\u691c\u51fa\u3092\u3059\u308b\u3068\u3057\u307e\u3059\u3002\u3057\u304b\u3057\u3001West Atto\u306e\u63a8\u5968\u4e8c\u6b21\u6297\u4f53\u5e0c\u91c8\u500d\u7387\u306f100,000\uff5e250,000\u500d\u306a\u306e\u3067\u30013,000\u500d\u5e0c\u91c8\u3067\u306f\u4e8c\u6b21\u6297\u4f53\u304c\u6fc3\u3059\u304e\u3066\u3001\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u304b\u306a\u308a\u9ad8\u304f\u306a\u308b\u3068\u4e88\u60f3\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001\u30c8\u30e9\u30d6\u30eb\u306e\u539f\u56e0\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u6297\u4f53\u306f\u3001\u691c\u51fa\u8a66\u85ac\u306e\u63a8\u5968\u6761\u4ef6\u306b\u5f93\u3063\u3066\u5e0c\u91c8\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u307e\u305f\u3001\u6297\u4f53\u306e\u5e0c\u91c8\u500d\u7387\u306f\u3001\u4e00\u822c\u7684\u306b\u3001\u6297\u4f53\u306e\u539f\u6db2\u304c1 mg\/m\uff2c\u3067\u3042\u308b\u3053\u3068\u3092\u524d\u63d0\u306b\u66f8\u304b\u308c\u3066\u3044\u307e\u3059\u3002\u3082\u3057\u8cfc\u5165\u3057\u305f\u6297\u4f53\u306e\u539f\u6db2\u6fc3\u5ea6\u304c1 mg\/m\uff2c\u3067\u306f\u306a\u3044\u5834\u5408\u3001\u5e0c\u91c8\u500d\u7387\u3082\u6fc3\u5ea6\u306b\u5fdc\u3058\u3066\u8a08\u7b97\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u4e00\u6b21\u6297\u4f53\u306e\u63a2\u3057\u65b9<\/h2>\n<p>\u3067\u306f\u3001\u5b9f\u969b\u306b\u6297\u4f53\u3092Web\u304b\u3089\u63a2\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306e\u30b5\u30a4\u30c8\u306e\u5de6\u4e0a\u306b\u3042\u308b\u300cSearch All\u300d\u306e\u30d7\u30eb\u30c0\u30a6\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001\u4e00\u6b21\u6297\u4f53\u3092\u9078\u629e\u3057\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-15406\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-05.jpg\" alt=\"\" width=\"906\" height=\"272\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-05.jpg 906w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-05-300x90.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-05-768x231.jpg 768w\" sizes=\"auto, (max-width: 906px) 100vw, 906px\" \/><br \/>\n\u3059\u308b\u3068\u3001\u4e0b\u56f3\u306e\u3088\u3046\u306b\u691c\u7d22\u30d0\u30fc\u304c\u5909\u308f\u308a\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-15407\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-06.jpg\" alt=\"\" width=\"946\" height=\"85\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-06.jpg 946w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-06-300x27.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-06-768x69.jpg 768w\" sizes=\"auto, (max-width: 946px) 100vw, 946px\" \/><br \/>\n\u300cTarget of interest(Target, gene, symbol, antigen)\u300d\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u540d\u3092\u5165\u529b\u3001\u300cApplication\u300d\u306e\u30d7\u30eb\u30c0\u30a6\u30f3\u304b\u3089\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u9078\u629e\u3001\u300cTarget Species\u300d\u306e\u30d7\u30eb\u30c0\u30a6\u30f3\u304b\u3089\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u52d5\u7269\u7a2e\u3092\u9078\u629e\u3057\u3001\u53f3\u7aef\u306e\u691c\u7d22\u30dc\u30bf\u30f3\u3092\u62bc\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u691c\u7d22\u7d50\u679c\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002<br \/>\n\u3055\u3089\u306b\u7d5e\u308a\u8fbc\u307f\u3092\u884c\u3044\u305f\u3044\u5834\u5408\u306f\u3001\u4e0b\u56f3\u8d64\u67a0\u304b\u3089\u3001\u691c\u7d22\u7d50\u679c\u3092\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u3067\u304d\u307e\u3059\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-15404\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-07.jpg\" alt=\"\" width=\"1713\" height=\"287\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-07.jpg 1713w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-07-300x50.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-07-1024x172.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-07-768x129.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-07-1536x257.jpg 1536w\" sizes=\"auto, (max-width: 1713px) 100vw, 1713px\" \/><br \/>\n\u4f8b\u3048\u3070\u3001\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u306b\u7d5e\u308a\u8fbc\u307f\u305f\u3044\u5834\u5408\u306f\u3001\u300cClonality\u300d\u304b\u3089\u300cPolyclonal\u300d\u3092\u9078\u629e\u3057\u3066\u304f\u3060\u3055\u3044\u3002<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-15405\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-08.jpg\" alt=\"\" width=\"280\" height=\"235\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-08.jpg 346w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/09\/western-blot-protein-ts-6-08-300x252.jpg 300w\" sizes=\"auto, (max-width: 280px) 100vw, 280px\" \/><br \/>\n\u4e8c\u6b21\u6297\u4f53\u3082\u3001\u540c\u69d8\u306b\u300cSearch All\u300d\u306e\u30d7\u30eb\u30c0\u30a6\u30f3\u304b\u3089\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3093\u3067\u3001\u691c\u7d22\u7d50\u679c\u3092\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u3057\u3066\u7d5e\u308a\u8fbc\u307f\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u6297\u4f53\u306e\u9078\u3073\u65b9\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002<\/p>\n<ul>\n<li>\u4e00\u6b21\u6297\u4f53\u3067\u306f\u3001\u30e2\u30ce\u30af\u30ed\u2015\u30ca\u30eb\u6297\u4f53\u3067\u306f\u975e\u7279\u7570\u7684\u53cd\u5fdc\u304c\u8d77\u3053\u308a\u306b\u304f\u304f\u3001\u4e00\u822c\u7684\u306a\u691c\u51fa\u611f\u5ea6\u306f\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u6297\u4f53\u306e\u65b9\u304c\u9ad8\u304f\u306a\u308a\u3084\u3059\u3044<\/li>\n<li>\u6297\u4f53\u306f\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u78ba\u8a8d\u6e08\u307f\u306e\u3082\u306e\u3092\u7528\u3044\u308b<\/li>\n<li>\u4e8c\u6b21\u6297\u4f53\u3067\u306f\u3001F(ab&#8217;)2\u6297\u4f53\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u975e\u7279\u7570\u53cd\u5fdc\u3092\u6291\u3048\u305f\u308a\u3001Cross-Absorbed\u30bf\u30a4\u30d7\u3067\u307b\u304b\u306e\u751f\u7269\u7a2e\u306b\u4ea4\u5dee\u6027\u306e\u306a\u3044\u6297\u4f53\u3092\u624b\u306b\u5165\u308c\u305f\u308a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b<\/li>\n<li>\u6297\u4f53\u306f\u3001TBS-T\u3084PBS-T\u3001\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u8a66\u85ac\u306a\u3069\u3067\u5e0c\u91c8\u3057\u3001\u305d\u306e\u5e0c\u91c8\u500d\u7387\u306f\u691c\u51fa\u8a66\u85ac\u306e\u63a8\u5968\u306b\u6cbf\u3046<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-7\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u6b21\u56de<\/a>\u306f\u3001\u691c\u51fa\u8a66\u85ac\u9078\u629e\u306e\u30dd\u30a4\u30f3\u30c8\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089\uff1a<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-1\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u88fd\u54c1\u9078\u3073\u306b\u3082\u3046\u56f0\u3089\u306a\u3044\uff01\u7b2c1\u56de\uff1a\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u62bd\u51fa\u65b9\u6cd5<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-2\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u88fd\u54c1\u9078\u3073\u306b\u3082\u3046\u56f0\u3089\u306a\u3044\uff01\u7b2c2\u56de\uff1a\u7dcf\u30bf\u30f3\u30d1\u30af\u8cea\u5b9a\u91cf\u30ad\u30c3\u30c8<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-3\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">SDS-PAGE\u306e\u9078\u3073\u65b9\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u88fd\u54c1\u9078\u3073\u306b\u3082\u3046\u56f0\u3089\u306a\u3044\uff01\u7b2c3\u56de<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-4\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u8ee2\u5199\u6761\u4ef6\u306e\u9078\u3073\u65b9\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u88fd\u54c1\u9078\u3073\u306b\u3082\u3046\u56f0\u3089\u306a\u3044\uff01\u7b2c4\u56de<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-5\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u8a66\u85ac\u306e\u30dd\u30a4\u30f3\u30c8\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u88fd\u54c1\u9078\u3073\u306b\u3082\u3046\u56f0\u3089\u306a\u3044\uff01\u7b2c5\u56de<\/a><br \/>\n\u6297\u4f53\u3092\u9078\u3076\u3068\u304d\u306b\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u88fd\u54c1\u9078\u3073\u7b2c6\u56de<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-7\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u5316\u5b66\u767a\u5149\u3068\u30de\u30eb\u30c1\u30d7\u30ec\u30c3\u30af\u30b9\u691c\u51fa\u306e\u9078\u629e\u30dd\u30a4\u30f3\u30c8\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c7\u56de<\/a><\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h3>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h2>\u30bf\u30f3\u30d1\u30af\u8cea\u5b9f\u9a13\u95a2\u9023\u3001\u305d\u306e\u4ed6\u306e\u8a18\u4e8b\u306f\u3053\u3061\u3089<\/h2>\n<table style=\"border-color: lightgray;border-collapse: collapse;padding: 20px\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"border-color: lightgray;padding: 20px\">\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic6\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c6\u56de\u3011\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u30b9\u30c8\u30ea\u30c3\u30d4\u30f3\u30b0\u6cd5\u3068\u30ea\u30d7\u30ed\u30fc\u30d3\u30f3\u30b0\u6cd5<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic7\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c7\u56de\u3011\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u300c\u30d5\u30a1\u30fc\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u300d\u8d85\u5165\u9580<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic15\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c15\u56de\u3011\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u86cd\u5149\u30d7\u30ed\u30fc\u30d6\u306e\u57fa\u790e<br \/>\n<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic16\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_western_blot_protein_ts_6_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c16\u56de\u3011\u86cd\u5149\u691c\u51fa\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u30fc\u3068\u306f\uff1f<br \/>\n<\/a><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Tween is a trademark of Croda Americas LLC.<br \/>\n\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u300c\u9078\u3073\u65b9\u300d\u306b\u3064\u3044\u3066\u9023\u8f09\u3057\u3066\u3044\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u3001\u524d\u56de\u306f\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306e\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u3001\u3064\u307e\u308a\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002 \u3053\u3053\u3067\u306f\u3001\u6297\u4f53\u3092\u9078\u3076\u3068\u304d<\/p>\n","protected":false},"author":975,"featured_media":13122,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[17],"division":[],"class_list":["post-15396","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-western-blotting","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de\" \/>\n<meta property=\"og:description\" content=\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u300c\u9078\u3073\u65b9\u300d\u306b\u3064\u3044\u3066\u9023\u8f09\u3057\u3066\u3044\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u3001\u524d\u56de\u306f\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306e\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u3001\u3064\u307e\u308a\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002 \u3053\u3053\u3067\u306f\u3001\u6297\u4f53\u3092\u9078\u3076\u3068\u304d\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-09-26T07:08:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-12T08:06:01+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"761\" \/>\n\t<meta property=\"og:image:height\" content=\"476\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"21\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de\",\"datePublished\":\"2023-09-26T07:08:19+00:00\",\"dateModified\":\"2025-08-12T08:06:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/\"},\"wordCount\":233,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/western.jpg\",\"keywords\":[\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/\",\"name\":\"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/western.jpg\",\"datePublished\":\"2023-09-26T07:08:19+00:00\",\"dateModified\":\"2025-08-12T08:06:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/western.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2022\\\/12\\\/western.jpg\",\"width\":761,\"height\":476,\"caption\":\"westernblotting\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/western-blot-protein-ts-6\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/","og_locale":"ja_JP","og_type":"article","og_title":"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de","og_description":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u300c\u9078\u3073\u65b9\u300d\u306b\u3064\u3044\u3066\u9023\u8f09\u3057\u3066\u3044\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u3001\u524d\u56de\u306f\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306e\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u3001\u3064\u307e\u308a\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002 \u3053\u3053\u3067\u306f\u3001\u6297\u4f53\u3092\u9078\u3076\u3068\u304d","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-09-26T07:08:19+00:00","article_modified_time":"2025-08-12T08:06:01+00:00","og_image":[{"width":761,"height":476,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"21\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de","datePublished":"2023-09-26T07:08:19+00:00","dateModified":"2025-08-12T08:06:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/"},"wordCount":233,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg","keywords":["\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/","name":"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg","datePublished":"2023-09-26T07:08:19+00:00","dateModified":"2025-08-12T08:06:01+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg","width":761,"height":476,"caption":"westernblotting"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/western-blot-protein-ts-6\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u4e00\u6b21\u6297\u4f53\u3068\u4e8c\u6b21\u6297\u4f53\u3092\u9078\u3076\u4e0a\u3067\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u3068\uff1a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u9078\u3073\u65b9\u3000\u7b2c6\u56de"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":17,"label":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg",760,475,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":17,"name":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0","slug":"western-blotting","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":27,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2022\/12\/western.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15396","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=15396"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15396\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/13122"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=15396"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=15396"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=15396"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=15396"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}