{"id":15537,"date":"2023-10-20T14:48:53","date_gmt":"2023-10-20T05:48:53","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=15537"},"modified":"2023-10-25T17:26:18","modified_gmt":"2023-10-25T08:26:18","slug":"single-use-bioreactor-bpg-1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/","title":{"rendered":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577"},"content":{"rendered":"<p>\u7d30\u80de\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u3084\u30a6\u30a4\u30eb\u30b9\u30d9\u30af\u30bf\u30fc\u306a\u3069\u306e\u76ee\u7684\u7269\u8cea\u3092\u751f\u7523\u3055\u305b\u308b\u30d0\u30a4\u30aa\u533b\u85ac\u88fd\u9020\u3067\u306f\u3001\u4e0a\u6d41\u5de5\u7a0b\u3067\u52d5\u7269\u7d30\u80de\u3092\u5927\u91cf\u306b\u57f9\u990a\u3059\u308b\u5de5\u7a0b\u304c\u751f\u3058\u307e\u3059\u3002\u30d5\u30e9\u30b9\u30b3\u3084\u30ed\u30c3\u30ab\u30fc\u5f0f\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u306e\u57f9\u990a\u3067\u306f\u57f9\u990a\u6db2\u4e2d\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u6570\u5341\u30ea\u30c3\u30c8\u30eb\u4ee5\u4e0a\u306e\u6db2\u91cf\u3067\u57f9\u990a\u3092\u884c\u3046\u5834\u5408\u306b\u306f\u3001\u4e0a\u9762\u304b\u3089\u3060\u3051\u3067\u306f\u306a\u304f\u3001\u57f9\u990a\u6db2\u4e2d\u306b\u3082\u30ac\u30b9\u3092\u5439\u8fbc\u307f\u3001\u7d30\u80de\u306b\u9178\u7d20\u3092\u4f9b\u7d66\u3059\u308b\u5fc5\u8981\u304c\u51fa\u3066\u304d\u307e\u3059\u3002<br \/>\n\u5f53\u793e\u3067\u3082\u3001\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3092\u53d6\u308a\u6271\u3063\u3066\u3044\u307e\u3059\u304c\u3001\u6db2\u4e2d\u901a\u6c17\u3067\u4f7f\u7528\u3055\u308c\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306f\u3001\u9577\u5e74\u7814\u7a76\u958b\u767a\u3092\u884c\u3063\u3066\u304a\u308a\u3001\u3088\u308a\u6700\u9069\u306a\u3082\u306e\u304c\u767b\u5834\u3057\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u5f53\u793e\u306e\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u6d3b\u8e8d\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u3001\u305d\u306e\u7279\u9577\u3092\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p><b>\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/b><br \/>\n\u30fb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u5f79\u5272\u3067\u3042\u308b\u990a\u6db2\u4e2d\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u306b\u3064\u3044\u3066\u77e5\u308a\u305f\u3044\u65b9<br \/>\n\u30fb\u30d9\u30c3\u30bb\u30eb\u9593\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u7dad\u6301\u306b\u3064\u3044\u3066\u77e5\u308a\u305f\u3044\u65b9<\/p>\n<h2>\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u306b\u304a\u3051\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u6b74\u53f2\u3068\u5404\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7279\u9577<\/h2>\n<p>\u5f53\u793e\u306e\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306f\u30012006\u5e74\u306e\u767a\u58f2\u4ee5\u6765\u3001\u5e38\u306b\u88fd\u54c1\u306e\u6539\u826f\u3092\u91cd\u306d\u3066\u304a\u308a\u307e\u3059\u3002\u8ca9\u58f2\u958b\u59cb\u5f53\u521d\u306f\u5186\u7b52\u5f62\u3067\u3057\u305f\u304c\u30012020\u5e74\u306b\u76f4\u65b9\u4f53\u30c7\u30b6\u30a4\u30f3\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/bioproduction\/single-use-bioprocessing\/single-use-equipment\/single-use-bioreactors\/dynadrive-sub.html?CID=single_use_bioreactor_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 Dynadrive\u2122 \u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\uff08S.U.B.\uff09<\/a>\u3092\u4e0a\u5e02\u3057\u307e\u3057\u305f\u3002\u30d9\u30c3\u30bb\u30eb\u30b5\u30a4\u30ba\u3082\u6700\u59275,000 L\u3068\u3044\u3046\u3001\u88fd\u9020\u898f\u6a21\u306e\u7d30\u80de\u57f9\u990a\u306b\u304a\u3044\u3066\u3082\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3092\u6d3b\u7528\u3044\u305f\u3060\u3051\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306e\u6539\u826f\u3068\u540c\u6642\u306b\u3001\u6db2\u4e2d\u901a\u6c17\u30e9\u30a4\u30f3\u3067\u3042\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3082\u6539\u826f\u304c\u52a0\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><iframe loading=\"lazy\" title=\"HyPerforma DynaDrive S.U.B.- Novel design and features to accommodate modern cell culture processes\" width=\"760\" height=\"428\" src=\"https:\/\/www.youtube.com\/embed\/inUJ3VctYTA?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" allowfullscreen><\/iframe><\/p>\n<p>\u521d\u671f\u306e\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u306f\u3001\u30aa\u30fc\u30d7\u30f3\u30d1\u30a4\u30d7\u578b\u3068\u547c\u3070\u308c\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u304c\u63a1\u7528\u3055\u308c\u3066\u3044\u307e\u3057\u305f\uff08\u56f31a\uff09\u3002\u3053\u306e\u30aa\u30fc\u30d7\u30f3\u30d1\u30a4\u30d7\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306f\u3001\u6db2\u4e2d\u901a\u6c17\u306e\u30db\u30fc\u30eb\u304c\u4e00\u3064\u3057\u304b\u306a\u304f\u3001\u5927\u304d\u306a\u6c17\u6ce1\u304c\u751f\u6210\u3055\u308c\u308b\u305f\u3081\u306b\u3059\u3050\u306b\u57f9\u990a\u6db2\u4e2d\u304b\u3089\u629c\u3051\u3066\u3057\u307e\u3044\u3001\u57f9\u990a\u6db2\u4e2d\u306e\u901a\u6c17\u30e9\u30a4\u30f3\u3068\u3057\u3066\u306f\u52b9\u7387\u304c\u826f\u304f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u7d9a\u3044\u3066\u63a1\u7528\u3055\u308c\u305f\u3082\u306e\u304c\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3067\u3059\uff08\u56f31b\uff09\u3002\u3053\u3061\u3089\u306f\u30b9\u30c6\u30a3\u30c3\u30af\u72b6\u3067\u3001\u8868\u9762\u306b20\uff5e40 \u03bcm\u306e\u30db\u30fc\u30eb\u304c\u7121\u6570\u306b\u7a7a\u3044\u3066\u3044\u307e\u3059\u3002\u30d5\u30ea\u30c3\u30c8\u306e\u5185\u90e8\u304b\u3089\u30ac\u30b9\u3092\u9001\u308a\u8fbc\u3080\u3053\u3068\u3067\u3001\u57f9\u990a\u6db2\u4e2d\u306b\u7d30\u304b\u306a\u6c17\u6ce1\u3092\u591a\u6570\u751f\u307f\u51fa\u3059\u3053\u3068\u304c\u3067\u304d\u3001\u57f9\u990a\u6db2\u4e2d\u306b\u52b9\u7387\u3088\u304f\u9178\u7d20\u3092\u4f9b\u7d66\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306b\u3082\u8ab2\u984c\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\u4e00\u3064\u76ee\u306f\u3001\u9ad8\u3044\u6d41\u91cf\u3092\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u5185\u306b\u6d41\u3059\u3053\u3068\u304c\u3067\u304d\u306a\u3044\u70b9\u3067\u3059\u3002\u901a\u6c17\u91cf\u304c\u5c11\u306a\u3044\u5834\u5408\u306b\u306f\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u9ad8\u3044kLa\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u4e00\u65b9\u3067\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3078\u306e\u30ac\u30b9\u6d41\u91cf\u3092\u9ad8\u304f\u3057\u3059\u304e\u308b\u3068\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u304b\u3089\u751f\u6210\u3055\u308c\u308b\u6c17\u6ce1\u540c\u58eb\u304c\u878d\u5408\u3057\u3001\u5927\u304d\u306a\u6c17\u6ce1\u3068\u306a\u3063\u3066\u6db2\u4e2d\u3078\u306e\u6ede\u5728\u6642\u9593\u304c\u77ed\u304f\u306a\u308b\u305f\u3081\u3001\u7d30\u80de\u3078\u306e\u9178\u7d20\u4f9b\u7d66\u80fd\u529b\u304c\u4e0b\u304c\u3063\u3066\u3057\u307e\u3044\u307e\u3059\u3002<br \/>\n\u4e8c\u3064\u76ee\u306f\u3001\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u306e\u7dad\u6301\u304c\u56f0\u96e3\u3067\u3042\u308b\u3053\u3068\u3067\u3059\u3002\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306b\u306f\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c8\u30b5\u30a4\u30ba\u3068\u30df\u30cb\u30b5\u30a4\u30ba\u306e2\u7a2e\u985e\u306e\u30b5\u30a4\u30ba\u304c\u3042\u308a\u3001\u3053\u308c\u3089\u304c50 L\u306b\u30822,000 L\u306b\u3082\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u300250 L\u306e\u30d9\u30c3\u30bb\u30eb\u306f\u5341\u5206\u306a\u30ac\u30b9\u4f9b\u7d66\u80fd\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u304c\u3001\u30d9\u30c3\u30bb\u30eb\u30b5\u30a4\u30ba\u304c\u5927\u304d\u304f\u306a\u308b\u3068\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30b5\u30a4\u30ba\u306e\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u307f\u3067\u306f\u9178\u7d20\u4f9b\u7d66\u80fd\u529b\u304c\u4e0d\u8db3\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u30db\u30fc\u30eb\u30b5\u30a4\u30ba\u306f20\uff5e40 \u03bcm\u3068\u5e45\u304c\u3042\u308a\u9178\u7d20\u4f9b\u7d66\u80fd\u529b\u306b\u3082\u500b\u4f53\u5dee\u304c\u751f\u3058\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u30d9\u30c3\u30bb\u30eb\u30b5\u30a4\u30ba\u9593\u304a\u3088\u3073\u30d0\u30c3\u30c1\u9593\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u7dad\u6301\u304c\u56f0\u96e3\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u305d\u3053\u3067\u3001\u5f53\u793e\u3067\u306f\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3088\u308a\u3082\u52b9\u7387\u3088\u304f\u3001\u304b\u3064\u7d30\u80de\u3078\u306e\u30b7\u30a7\u30a2\u30b9\u30c8\u30ec\u30b9\u3092\u4f4e\u6e1b\u3067\u304d\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u958b\u767a\u306b\u53d6\u308a\u7d44\u307f\u3001\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u304c\u8a95\u751f\u3057\u307e\u3057\u305f\uff08\u56f31c\uff09\u3002\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306f\u3001\u30c7\u30a3\u30b9\u30af\u72b6\u306e\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3067\u3001\u30d9\u30c3\u30bb\u30eb\u30b5\u30a4\u30ba\u306b\u5408\u308f\u305b\u3066\u30db\u30fc\u30eb\u30b5\u30a4\u30ba\u3084\u30db\u30fc\u30eb\u6570\u3001\u30c7\u30a3\u30b9\u30af\u30b5\u30a4\u30ba\u3092\u5909\u66f4\u3059\u308b\u3053\u3068\u3067\u3001\u30d9\u30c3\u30bb\u30eb\u30b5\u30a4\u30ba\u9593\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u3092\u7dad\u6301\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30db\u30fc\u30eb\u306f\u30ec\u30fc\u30b6\u30fc\u3067\u7cbe\u5bc6\u306b\u8a2d\u8a08\u3055\u308c\u3066\u304a\u308a\u3001\u5747\u4e00\u306a\u30b5\u30a4\u30ba\u306e\u6c17\u6ce1\u3092\u7cbe\u88fd\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u30d0\u30c3\u30c1\u9593\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u3082\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15543\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15543\" class=\"size-large wp-image-15543\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/37dca2f33c0874ec1b92ec4a51be5f07-1024x576.jpg\" alt=\"\u56f31. \u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\" width=\"760\" height=\"428\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/37dca2f33c0874ec1b92ec4a51be5f07-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/37dca2f33c0874ec1b92ec4a51be5f07-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/37dca2f33c0874ec1b92ec4a51be5f07-768x432.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/37dca2f33c0874ec1b92ec4a51be5f07-1536x864.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/37dca2f33c0874ec1b92ec4a51be5f07.jpg 2000w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-15543\" class=\"wp-caption-text\">\u56f31. \u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e<\/p><\/div>\n<p>\u56f32\u306b\u3001\u30aa\u30fc\u30d7\u30f3\u30d1\u30a4\u30d7\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3001\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u9178\u7d20\u4f9b\u7d66\u9762\u304b\u3089\u307f\u305fkLa\u3068\u3001CO<sub>2<\/sub>\u30b9\u30c8\u30ea\u30c3\u30d4\u30f3\u30b0\u52b9\u7387\u304b\u3089\u307f\u305fkLa\u306e\u6bd4\u8f03\u3092\u793a\u3057\u307e\u3059\u3002\u56f32\uff08a\uff09\u306b\u793a\u3059\u901a\u308a\u3001\u9178\u7d20\u306e\u4f9b\u7d66\u80fd\u529b\u3068\u3057\u3066\u306f\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u304c\u512a\u308c\u3066\u304a\u308a\u3001\u7d040.02 VVM\u306725\/hr\u3092\u8d85\u3048\u308bkLa\u3092\u9054\u6210\u3057\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u56f32\uff08b\uff09\u3067\u306f\u3001CO<sub>2<\/sub>\u30b9\u30c8\u30ea\u30c3\u30d4\u30f3\u30b0\u52b9\u7387\u3092\u793a\u3057\u3066\u304a\u308a\u30010.02 VVM\u307e\u3067\u306f\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3067\u9ad8\u3044CO<sub>2<\/sub>\u30b9\u30c8\u30ea\u30c3\u30d4\u30f3\u30b0\u304c\u898b\u3089\u308c\u307e\u3059\u304c\u3001\u30ac\u30b9\u306e\u5439\u8fbc\u307f\u91cf\u304c\u591a\u304f\u306a\u308b\u306b\u3064\u308c\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3088\u308a\u3082\u5927\u304d\u306a\u6c17\u6ce1\u3067\u3001\u304b\u3064\u30aa\u30fc\u30d7\u30f3\u30d1\u30a4\u30d7\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3088\u308a\u3082\u591a\u304f\u306e\u6c17\u6ce1\u3092\u751f\u6210\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u304c\u6700\u3082\u52b9\u7387\u3088\u304fCO<sub>2<\/sub>\u30b9\u30c8\u30ea\u30c3\u30d4\u30f3\u30b0\u3092\u4fc3\u3057\u3001\u57f9\u990a\u6db2\u4e2d\u304c\u9178\u6027\u306b\u50be\u304d\u3059\u304e\u308b\u3053\u3068\u3092\u9632\u3044\u3067\u3044\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15545\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15545\" class=\"size-large wp-image-15545\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/732c7f6707fb070195965d6187574efe-1024x576.jpg\" alt=\"\u56f32. \u5404\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3067\u306eO2, CO2 Kla\u306e\u6bd4\u8f03\" width=\"760\" height=\"428\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/732c7f6707fb070195965d6187574efe-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/732c7f6707fb070195965d6187574efe-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/732c7f6707fb070195965d6187574efe-768x432.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/732c7f6707fb070195965d6187574efe-1536x864.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/732c7f6707fb070195965d6187574efe.jpg 2000w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-15545\" class=\"wp-caption-text\">\u56f32. \u5404\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3067\u306eO<sub>2<\/sub>\u3001 CO<sub>2<\/sub> Kla\u306e\u6bd4\u8f03<\/p><\/div>\n<h2>\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\uff5e\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u9032\u5316\uff5e<\/h2>\n<p>\u56f32\u306e\u30b0\u30e9\u30d5\u3088\u308a\u3001\u9178\u7d20\u4f9b\u7d66\u80fd\u529b\u306f\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u307b\u3046\u304c\u9ad8\u304f\u3001CO<sub>2<\/sub>\u30b9\u30c8\u30ea\u30c3\u30d4\u30f3\u30b0\u52b9\u7387\u306f\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u307b\u3046\u304c\u9ad8\u3044\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u304c\u3001\u9178\u7d20\u4f9b\u7d66\u7528\u306b\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3001CO<sub>2<\/sub>\u30b9\u30c8\u30ea\u30c3\u30d4\u30f3\u30b0\u7528\u306b\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3068\u4f7f\u3044\u5206\u3051\u308b\u3053\u3068\u306f\u52b9\u7387\u304c\u826f\u3044\u3068\u306f\u8a00\u3048\u307e\u305b\u3093\u3002\u307e\u305f\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306b\u306f\u3001\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u306e\u7dad\u6301\u304c\u56f0\u96e3\u3068\u3044\u3046\u8ab2\u984c\u304c\u6b8b\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3053\u3067\u5f53\u793e\u306f\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7814\u7a76\u958b\u767a\u3092\u9032\u3081\u3001\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u304c\u8a95\u751f\u3057\u307e\u3057\u305f\u3002\u88681\u306b\u5f93\u6765\u304a\u3088\u3073\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u30db\u30fc\u30eb\u30b5\u30a4\u30ba\u3068\u30db\u30fc\u30eb\u6570\u3092\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306f\u5f93\u6765\u54c1\u3068\u6bd4\u8f03\u3057\u3066\u30db\u30fc\u30eb\u30b5\u30a4\u30ba\u304c\u5c0f\u3055\u304f\u3001\u30db\u30fc\u30eb\u6570\u306f\u5897\u52a0\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15548\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15548\" class=\"size-large wp-image-15548\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a31f07e9074a2c1771baabf98309a960-1024x576.jpg\" alt=\"\u56f33. \u30c9\u30ea\u30eb\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u30db\u30fc\u30eb\u30b5\u30a4\u30ba\u3068\u30db\u30fc\u30eb\u6570\u306e\u6bd4\u8f03\" width=\"760\" height=\"428\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a31f07e9074a2c1771baabf98309a960-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a31f07e9074a2c1771baabf98309a960-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a31f07e9074a2c1771baabf98309a960-768x432.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a31f07e9074a2c1771baabf98309a960-1536x864.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a31f07e9074a2c1771baabf98309a960.jpg 2000w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-15548\" class=\"wp-caption-text\">\u56f33. \u30c9\u30ea\u30eb\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u30db\u30fc\u30eb\u30b5\u30a4\u30ba\u3068\u30db\u30fc\u30eb\u6570\u306e\u6bd4\u8f03<\/p><\/div>\n<p>\u56f33\u306b50 L DynaDrive S.U.B.\u306b\u3066\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3001\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3068\u5f93\u6765\u306e\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u4f75\u7528\u3001\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3057\u305f\u969b\u306b\u5f97\u3089\u308c\u308bkLa\u306e\u6bd4\u8f03\u3092\u793a\u3057\u307e\u3059\u3002\u7e26\u8ef8\u306bkLa\u3001\u6a2a\u8ef8\u306b\u30ac\u30b9\u5439\u8fbc\u307f\u91cf\u3092\u53d6\u3063\u3066\u304a\u308a\u3001\u8d64\u7dda\u3067\u793a\u3057\u3066\u3044\u308b\u306e\u304c\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u307f\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u9ec4\u8272\u3067\u793a\u3057\u3066\u3044\u308b\u306e\u304c\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3068\u5f93\u6765\u306e\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u9ed2\u8272\u3067\u793a\u3057\u3066\u3044\u308b\u306e\u304c\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3067\u3059\u3002\u30d5\u30ea\u30c3\u30c8\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u30010.02 VVM\u7a0b\u5ea6\u306e\u4f4e\u3044\u30ac\u30b9\u4f9b\u7d66\u91cf\u3067\u308230\/hr\u7a0b\u5ea6\u306ekLa\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u5f93\u6765\u306e\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3068\u4f75\u7528\u3059\u308b\u3053\u3068\u3067\u300140\/hr\u306ekLa\u3092\u9054\u6210\u3067\u304d\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u305f\u305f\u3081\u3001\u901a\u5e38\u306e\u57f9\u990a\u3067\u5341\u5206\u306b\u5bfe\u5fdc\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3068\u3044\u3048\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u30ac\u30b9\u306e\u5439\u8fbc\u307f\u91cf\u306b\u6bd4\u4f8b\u3057\u3066kLa\u3082\u9ad8\u304f\u306a\u308a\u30010.15 VVM\u3067\u306f50\/hr\u3092\u8d85\u3048\u308bkLa\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u306e\u3053\u3068\u304b\u3089\u3001\u8fd1\u5e74\u306e\u30c8\u30ec\u30f3\u30c9\u3067\u3042\u308b\u30d1\u30fc\u30d5\u30e5\u30fc\u30b8\u30e7\u30f3\u57f9\u990a\u3084\u9ad8\u5bc6\u5ea6\u57f9\u990a\u3092\u8996\u91ce\u306b\u5165\u308c\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15549\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15549\" class=\"size-large wp-image-15549\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a7b125f104923e18d39f062f9f1aa76e-1024x576.jpg\" alt=\"\u56f34. 50L DynaDrive S.U.B. \u306b\u3066\uff1a\u5404\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3067\u5f97\u3089\u308c\u308bkLa\u6bd4\u8f03\" width=\"760\" height=\"428\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a7b125f104923e18d39f062f9f1aa76e-1024x576.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a7b125f104923e18d39f062f9f1aa76e-300x169.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a7b125f104923e18d39f062f9f1aa76e-768x432.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a7b125f104923e18d39f062f9f1aa76e-1536x864.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/a7b125f104923e18d39f062f9f1aa76e.jpg 2000w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-15549\" class=\"wp-caption-text\">\u56f34. 50L DynaDrive S.U.B. \u306b\u3066\uff1a\u5404\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3067\u5f97\u3089\u308c\u308bkLa\u6bd4\u8f03<\/p><\/div>\n<p>\u30a8\u30f3\u30cf\u30f3\u30b9\u30c8\u30fb\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306f\u73fe\u5728\u3001\u5f53\u793e\u306e\u6700\u65b0\u578b\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u3042\u308bDynaDrive S.U.B.\u304a\u3088\u3073\u30de\u30a4\u30af\u30ed\u30ad\u30e3\u30ea\u30a2\u57f9\u990a\u306b\u3082\u5bfe\u5fdc\u53ef\u80fd\u306aThermo Scientific\u2122 Enhanced HyPerforma\u2122 S.U.B.\u306b\u63a1\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u30d9\u30c3\u30bb\u30eb\u9593\u306e\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u7dad\u6301\u306b\u8ca2\u732e\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u3001\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u3066\u3001\u57f9\u990a\u6db2\u4e2d\u306e\u30ac\u30b9\u4f9b\u7d66\u3067\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3059\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u3092\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u5f53\u793e\u306e\u6700\u65b0\u578b\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u306b\u306f\u3001\u30d9\u30c3\u30bb\u30eb\u30b5\u30a4\u30ba\u3054\u3068\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30c9\u30ea\u30eb\u30c9\u30db\u30fc\u30eb\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u304c\u63a1\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u30b9\u30b1\u30fc\u30e9\u30d3\u30ea\u30c6\u30a3\u306e\u7dad\u6301\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/bioproduction\/single-use-bioprocessing\/single-use-equipment\/single-use-bioreactors\/dynadrive-sub.html?CID=single_use_bioreactor_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122Dynadrive\u2122\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\uff08S.U.B.\uff09<\/a>\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/clinical\/cell-gene-therapy\/creative-experience-lab.html?CID=single_use_bioreactor_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u518d\u751f\u533b\u7642\u30af\u30ea\u30a8\u30a4\u30c6\u30a3\u30d6\u30fb\u30a8\u30af\u30b9\u30da\u30ea\u30a8\u30f3\u30b9\u30fb\u30e9\u30dc\uff08Thermo Fisher Scientific Creative Experience Lab for regenerative medicine: T-CEL\uff09<\/a>\u306b\u3066\u898b\u5b66\u304c\u53ef\u80fd\u3067\u3059\u306e\u3067\u898b\u5b66\u3092\u5e0c\u671b\u3055\u308c\u308b\u5834\u5408\u306f<a href=\"https:\/\/forms.office.com\/r\/cUu9KVCBWG?CID=single_use_bioreactor_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u3078\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u307e\u305f\u3001\u4eca\u56de\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305fDynaDrive\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u304a\u3088\u3073\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u88fd\u54c1\u306b\u95a2\u3059\u308b\u95a2\u9023\u8cc7\u6599\u306f\u3001\u4e0b\u8a18\u30ea\u30f3\u30af\u3088\u308a\u3054\u78ba\u8a8d\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<h3>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30b7\u30f3\u30b0\u30eb\u30e6\u30fc\u30b9\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u88fd\u54c1\u95a2\u9023\u8cc7\u6599<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/single-use-docdl.html?CID=single_use_bioreactor_bpg_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u307e\u305f\u306f\u88fd\u9020\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u306e\u4f7f\u7528\u3001\u30d2\u30c8\u304a\u3088\u3073\u52d5\u7269\u3078\u306e\u76f4\u63a5\u7684\u306a\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7d30\u80de\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u3084\u30a6\u30a4\u30eb\u30b9\u30d9\u30af\u30bf\u30fc\u306a\u3069\u306e\u76ee\u7684\u7269\u8cea\u3092\u751f\u7523\u3055\u305b\u308b\u30d0\u30a4\u30aa\u533b\u85ac\u88fd\u9020\u3067\u306f\u3001\u4e0a\u6d41\u5de5\u7a0b\u3067\u52d5\u7269\u7d30\u80de\u3092\u5927\u91cf\u306b\u57f9\u990a\u3059\u308b\u5de5\u7a0b\u304c\u751f\u3058\u307e\u3059\u3002\u30d5\u30e9\u30b9\u30b3\u3084\u30ed\u30c3\u30ab\u30fc\u5f0f\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u306e\u57f9\u990a\u3067\u306f\u57f9\u990a\u6db2\u4e2d\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u6570<\/p>\n","protected":false},"author":975,"featured_media":15563,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[23],"division":[],"class_list":{"0":"post-15537","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell","8":"tag-cell-culture","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577\" \/>\n<meta property=\"og:description\" content=\"\u7d30\u80de\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u3084\u30a6\u30a4\u30eb\u30b9\u30d9\u30af\u30bf\u30fc\u306a\u3069\u306e\u76ee\u7684\u7269\u8cea\u3092\u751f\u7523\u3055\u305b\u308b\u30d0\u30a4\u30aa\u533b\u85ac\u88fd\u9020\u3067\u306f\u3001\u4e0a\u6d41\u5de5\u7a0b\u3067\u52d5\u7269\u7d30\u80de\u3092\u5927\u91cf\u306b\u57f9\u990a\u3059\u308b\u5de5\u7a0b\u304c\u751f\u3058\u307e\u3059\u3002\u30d5\u30e9\u30b9\u30b3\u3084\u30ed\u30c3\u30ab\u30fc\u5f0f\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u306e\u57f9\u990a\u3067\u306f\u57f9\u990a\u6db2\u4e2d\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u6570\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-10-20T05:48:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-10-25T08:26:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"328\" \/>\n\t<meta property=\"og:image:height\" content=\"200\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577\",\"datePublished\":\"2023-10-20T05:48:53+00:00\",\"dateModified\":\"2023-10-25T08:26:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/\"},\"wordCount\":119,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/10\\\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg\",\"keywords\":[\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/\",\"name\":\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/10\\\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg\",\"datePublished\":\"2023-10-20T05:48:53+00:00\",\"dateModified\":\"2023-10-25T08:26:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/10\\\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/10\\\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg\",\"width\":328,\"height\":200},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/single-use-bioreactor-bpg-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577","og_description":"\u7d30\u80de\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u3084\u30a6\u30a4\u30eb\u30b9\u30d9\u30af\u30bf\u30fc\u306a\u3069\u306e\u76ee\u7684\u7269\u8cea\u3092\u751f\u7523\u3055\u305b\u308b\u30d0\u30a4\u30aa\u533b\u85ac\u88fd\u9020\u3067\u306f\u3001\u4e0a\u6d41\u5de5\u7a0b\u3067\u52d5\u7269\u7d30\u80de\u3092\u5927\u91cf\u306b\u57f9\u990a\u3059\u308b\u5de5\u7a0b\u304c\u751f\u3058\u307e\u3059\u3002\u30d5\u30e9\u30b9\u30b3\u3084\u30ed\u30c3\u30ab\u30fc\u5f0f\u30d0\u30a4\u30aa\u30ea\u30a2\u30af\u30bf\u30fc\u3067\u306e\u57f9\u990a\u3067\u306f\u57f9\u990a\u6db2\u4e2d\u3078\u306e\u30ac\u30b9\u4f9b\u7d66\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u6570","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-10-20T05:48:53+00:00","article_modified_time":"2023-10-25T08:26:18+00:00","og_image":[{"width":328,"height":200,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577","datePublished":"2023-10-20T05:48:53+00:00","dateModified":"2023-10-25T08:26:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/"},"wordCount":119,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg","keywords":["\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/","name":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg","datePublished":"2023-10-20T05:48:53+00:00","dateModified":"2023-10-25T08:26:18+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg","width":328,"height":200},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/single-use-bioreactor-bpg-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3053\u308c\u3092\u8aad\u3081\u3070\u308f\u304b\u308b\uff01 \u52d5\u7269\u7d30\u80de\u57f9\u990a\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u30b9\u30d1\u30fc\u30b8\u30e3\u30fc\u306e\u7a2e\u985e\u3068\u7279\u9577"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-1024x576.jpg",760,428,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":64,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/10\/single-use-bioreactor-bpg-1-image-e1698222352188.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=15537"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15537\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/15563"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=15537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=15537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=15537"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=15537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}