{"id":1588,"date":"2019-05-22T00:00:00","date_gmt":"2019-05-21T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/"},"modified":"2023-08-15T11:55:29","modified_gmt":"2023-08-15T02:55:29","slug":"gas_chromatography","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/","title":{"rendered":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044GC\u306e\u57fa\u790e"},"content":{"rendered":"<p><strong><span style=\"font-size: 14pt\">GC (\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff09\u3068\u306f\uff1f<\/span><\/strong><\/p>\n<p>GC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08Gas Chromatography\uff09\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3001HPLC\uff08\u9ad8\u901f\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff09\u3068\u4e26\u3073\u3082\u3063\u3068\u3082\u30dd\u30d4\u30e5\u30e9\u30fc\u306a\u5b9a\u6027\u30fb\u5b9a\u91cf\u5206\u6790\u624b\u6cd5\u306e\u3072\u3068\u3064\u3068\u3057\u3066\u5e83\u304f\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002GC\u306fHPLC\u3088\u308a\u3082\u65e9\u304f\u4e16\u754c\u306b\u666e\u53ca\u3057\u305f\u5206\u6790\u624b\u6cd5\u3067\u3001\u958b\u767a\u5f53\u521d\u306e1950\u5e74\u4ee3\u306b\u306f\u77f3\u6cb9\u7523\u696d\u3092\u4e2d\u5fc3\u306b\u591a\u7528\u3055\u308c\u3066\u3044\u307e\u3057\u305f\u3002\u73fe\u5728\u3067\u306f\u98df\u54c1\u3084\u74b0\u5883\u3001\u5316\u5b66\u3001\u88fd\u85ac\u3001\u6cd5\u533b\u5b66\u306a\u3069GC\u306e\u6d3b\u8e8d\u306e\u5834\u306f\u975e\u5e38\u306b\u5e45\u5e83\u304f\u3001HPLC\u3068\u3068\u3082\u306b\u4eca\u65e5\u306e\u79d1\u5b66\u8005\u3092\u652f\u3048\u308b\u91cd\u8981\u306a\u6280\u8853\u3068\u3057\u3066\u305d\u306e\u5730\u4f4d\u3092\u78ba\u7acb\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>GC\u306f\u4e3b\u306b\u6c17\u4f53\u3001\u6db2\u4f53\u306e\u8a66\u6599\u306e\u6e2c\u5b9a\u306b\u9069\u3057\u3066\u304a\u308a\u3001\u591a\u6210\u5206\u3092\u8fc5\u901f\u304b\u3064\u540c\u6642\u306b\u5b9a\u6027\u30fb\u5b9a\u91cf\u304c\u53ef\u80fd\u3067\u3001\u307e\u305f\u5206\u6790\u5024\u306e\u518d\u73fe\u6027\u306b\u3082\u512a\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u7279\u9577\u3067\u3059\u3002\u6db2\u4f53\u8a66\u6599\u306e\u5834\u5408\u306f\u8a66\u6599\u91cf\u304c1 \u03bcL\u7a0b\u5ea6\u3067\u3082\u5206\u6790\u3067\u304d\u308b\u3053\u3068\u304b\u3089\u3001\u5e0c\u5c11\u306a\u8a66\u6599\u306e\u5206\u6790\u306b\u3082\u5bfe\u5fdc\u3067\u304d\u307e\u3059\u3002GC\u3082HPLC\u3068\u540c\u3058\u304f\u3001\u5206\u6790\u8005\u306e\u76ee\u7684\u306b\u5fdc\u3058\u3066\u305d\u306e\u88c5\u7f6e\u306e\u69cb\u6210\u3084\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u9078\u5b9a\u3059\u308b\u3053\u3068\u3067\u3001\u5e45\u5e83\u3044\u8a66\u6599\u9069\u7528\u6027\u3068\u9ad8\u3044\u5206\u6790\u7cbe\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u691c\u51fa\u5668\u306b\u3064\u3044\u3066\u306fHPLC\u3067\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u3082\u306e\u3068\u539f\u7406\u3084\u5206\u6790\u7a2e\u306b\u5bfe\u3059\u308b\u611f\u5ea6\u3084\u691c\u51fa\u306e\u9078\u629e\u6027\u304c\u7570\u306a\u308b\u3082\u306e\u304c\u591a\u3044\u305f\u3081\u3001\u5206\u6790\u306e\u76ee\u7684\u3084\u5bfe\u8c61\u8a66\u6599\u306e\u6027\u72b6\u306b\u5fdc\u3058\u3066GC\u3068HPLC\u306e\u3069\u3061\u3089\u3067\u5206\u6790\u3092\u884c\u3046\u304b\u3092\u6c7a\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306fGC\u306b\u95a2\u3059\u308b\u57fa\u790e\u3092\u3054\u8aac\u660e\u3044\u305f\u3057\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3064\u3044\u3066\u306e\u7c21\u5358\u306a\u8aac\u660e\u306f\u300c\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044HPLC\u306e\u57fa\u790e\u300d\u3067\u89e6\u308c\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u2192\u2192<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/hplc_basic\/?ICID=cmd_gc_r04_jp_gas_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044HPLC\u306e\u57fa\u790e\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fbGC\u521d\u5fc3\u8005\u3067\u3001\u57fa\u672c\u304b\u3089\u5b66\u3073\u305f\u3044\u65b9\u3002<br \/>\n\u30fbGC\u3092\u3053\u308c\u304b\u3089\u521d\u3081\u3066\u4f7f\u3046\u65b9<br \/>\n\u30fbGC\u306e\u57fa\u672c\u4e8b\u9805\u3092\u304a\u3055\u3089\u3044\u3057\u305f\u3044\u65b9<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/072420-gc-basic-article.html?ICID=cmd_gc_r04_jp_gas_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">PDF\u7248\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>GC\u306e\u7279\u9577<\/h2>\n<p style=\"background: white;vertical-align: baseline\"><span lang=\"EN-US\">GC<\/span>\u306f<span lang=\"EN-US\">HPLC<\/span>\u3068\u540c\u3058\u304f\u6c4e\u7528\u6027\u306e\u9ad8\u3044\u5206\u6790\u624b\u6cd5\u3068\u3057\u3066\u69d8\u3005\u306a\u79d1\u5b66\u5206\u91ce\u3067\u591a\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001<span lang=\"EN-US\">GC<\/span>\u3068<span lang=\"EN-US\">HPLC<\/span>\u306e\u4f7f\u3044\u5206\u3051\u306b\u304a\u3044\u3066\u91cd\u8981\u3068\u306a\u308b\u306e\u304c\u3001\u5206\u6790\u7a2e\uff08\u6e2c\u5b9a\u5bfe\u8c61\u6210\u5206\uff09\u306e\u300c\u6cb8\u70b9\u300d\u3084\u300c\u5206\u5b50\u91cf\u300d\u3067\u3059\u3002<span lang=\"EN-US\">GC<\/span>\u306f\u305d\u306e\u539f\u7406\u4e0a\u3001\u5206\u6790\u7a2e\u304a\u3088\u3073\u8a66\u6599\u6eb6\u5a92\u304c\u5b89\u5b9a\u3057\u3066\u6c17\u5316\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u3088\u3046\u306b\u5206\u5b50\u91cf\u304c\u5927\u304d\u3044\u5316\u5408\u7269\u3084\u3001\u98df\u5869\u306e\u3088\u3046\u306b\u5206\u5b50\u91cf\u304c\u5c0f\u3055\u304f\u3066\u3082\u9ad8\u6cb8\u70b9\u306e\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u306f\u6c17\u5316\u304c\u56f0\u96e3\u306a\u305f\u3081\u3001<span lang=\"EN-US\">GC<\/span>\u3078\u306e\u9069\u7528\u306f\u4e00\u822c\u7684\u306b\u4e0d\u5411\u304d\u3068\u3055\u308c\u307e\u3059\u3002\u4ed6\u65b9\u3001\u70ad\u7d20\u6570\u306e\u4f4e\u3044\u70ad\u5316\u6c34\u7d20\u3001\u4f8b\u3048\u3070\u30d8\u30ad\u30b5\u30f3\u306e\u3088\u3046\u306a\u5206\u6790\u7a2e\u306e\u5834\u5408\u3001<span lang=\"EN-US\">HPLC<\/span>\u3092\u7528\u3044\u308b\u5206\u6790\u3067\u306f\u691c\u51fa\u611f\u5ea6\u304c\u554f\u984c\u3068\u306a\u308b\u305f\u3081\u3001<span lang=\"EN-US\">GC<\/span>\u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u3002<\/p>\n<p style=\"background: white;vertical-align: baseline\"><span lang=\"EN-US\">GC<\/span>\u306e\u4e00\u822c\u7684\u306a\u30dd\u30c6\u30f3\u30b7\u30e3\u30eb\u3068\u3057\u3066\u3001\u4e0b\u8a18\u306e\u3088\u3046\u306a\u7279\u5fb4\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u30fb1\u56de\u306e\u5206\u6790\u3067\u8907\u6570\u306e\u5206\u6790\u7a2e\uff08\u6eb6\u8cea\u3084\u30ac\u30b9\u6210\u5206\uff09\u3092\u540c\u6642\u306b\u5b9a\u6027\u30fb\u5b9a\u91cf\u304c\u53ef\u80fd<\/p>\n<p>\u30fb\u5206\u6790\u306e\u611f\u5ea6\u306f\u88c5\u7f6e\u306e\u69cb\u6210\u3084\u5206\u6790\u6761\u4ef6\u306e\u8a2d\u5b9a\u306b\u3088\u308a\u3001\uff05\u304b\u3089ppt\u30aa\u30fc\u30c0\u30fc\u307e\u3067\u5e45\u304c\u5e83\u3044<\/p>\n<p>\u30fb\u5bfe\u8c61\u3068\u306a\u308b\u5206\u6790\u7a2e\u306f\u4f4e\u5206\u5b50\uff08\u76ee\u5b89\u3068\u3057\u3066\u5206\u5b50\u91cf1000\u4ee5\u4e0b\u3001\u6cb8\u70b9500\u2103\u4ee5\u4e0b\uff09\u3067\u3001\u304b\u3064\u71b1\u5b89\u5b9a\u6027\u306e\u9ad8\u3044\u3082\u306e<\/p>\n<p>\u30fbHPLC\u3067\u306f\u5206\u96e2\u3001\u5b9a\u6027\u3001\u5b9a\u91cf\u304c\u56f0\u96e3\u306a\u5206\u6790\u7a2e\uff08\u7121\u6a5f\u30ac\u30b9\u306a\u3069\uff09\u3084\u30ac\u30b9\u8a66\u6599\u306b\u3064\u3044\u3066\u3001\u5b9a\u6027\u30fb\u5b9a\u91cf\u304c\u53ef\u80fd\u306a\u4e8b\u4f8b\u3082\u591a\u3044<\/p>\n<p>\u30fb\u5206\u6790\u7a2e\u306e\u5206\u96e2\u30fb\u5206\u6790\u306e\u53ef\u5426\u306f\u300c\u8a66\u6599\u6ce8\u5165\u53e3\u306e\u6761\u4ef6\u300d\u3001\u300cGC\u56fa\u5b9a\u76f8\uff08\u30ab\u30e9\u30e0\uff09\u306e\u7a2e\u985e\u300d\u3001\u300c\u30ab\u30e9\u30e0\u6e29\u5ea6\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\u300d\u306b\u3088\u308a\u6c7a\u5b9a\u3059\u308b\uff08\u5b9f\u969b\u306e\u8a66\u6599\u6e2c\u5b9a\u3067\u306f\u8a66\u6599\u4e2d\u306b\u5206\u6790\u7a2e\u4ee5\u5916\u306e\u593e\u96d1\u6210\u5206\u304c\u5b58\u5728\u3059\u308b\u30b1\u30fc\u30b9\u304c\u591a\u304f\u3001\u5206\u6790\u8005\u306f\u305d\u306e\u8a66\u6599\u306e\u6e2c\u5b9a\u306b\u6700\u9069\u306a\u5206\u6790\u6761\u4ef6\u306e\u691c\u8a0e\u304c\u5fc5\u8981\u3068\u306a\u308b\u3002\u3053\u306e\u691c\u8a0e\u306e\u306a\u304b\u3067\u3001\u8a66\u6599\u6ce8\u5165\u53e3\u6761\u4ef6\u3084\u30ab\u30e9\u30e0\u306e\u7a2e\u985e\u306a\u3069\u306e\u8af8\u6761\u4ef6\u306e\u201c\u7d44\u307f\u5408\u308f\u305b\u201d\u306f\u5206\u6790\u306e\u53ef\u5426\u3092\u5927\u304d\u304f\u5de6\u53f3\u3059\u308b\u3002\uff09<\/p>\n<p>\u30fb\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u975e\u5e38\u306b\u512a\u308c\u305f\u5206\u96e2\u80fd\u30fb\u611f\u5ea6\u3092\u5f97\u3089\u308c\u3084\u3059\u304f\u306a\u308b<\/p>\n<p>\u30fb\u5206\u6790\u7d50\u679c\u306f\u518d\u73fe\u6027\u306b\u512a\u308c\u308b\u304c\u3001\u8a66\u6599\u6ce8\u5165\u306b\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u306a\u3069\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3088\u308a\u9ad8\u3044\u518d\u73fe\u6027\u3092\u78ba\u4fdd\u3067\u304d\u3001\u3055\u3089\u306b\u751f\u7523\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd<\/p>\n<p>\u30fb\u691c\u51fa\u5668\u306b\u8cea\u91cf\u5206\u6790\u8a08\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u672a\u77e5\u8a66\u6599\u4e2d\u306e\u5316\u5b66\u7a2e\u3092\u3088\u308a\u7cbe\u5bc6\u306b\u540c\u5b9a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd<\/p>\n<h2>GC\u3067\u6e2c\u5b9a\u3067\u304d\u308b\u6210\u5206<\/h2>\n<p>GC\u3067\u306f\u4e0a\u8ff0\u306e\u901a\u308a\u3001\u8a66\u6599\u304c\u6c17\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u305f\u3081\u5bfe\u8c61\u3068\u306a\u308b\u5206\u6790\u7a2e\u3082\u540c\u3058\u304f\u63ee\u767a\u6027\u6210\u5206\u304c\u57fa\u672c\u3068\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u4f4e\u5206\u5b50\u3067\u3042\u3063\u3066\u3082\u30a4\u30aa\u30f3\u6027\u306e\u6210\u5206\u3067\u3042\u308c\u3070\u3001HPLC\u306e\u4e00\u7a2e\u3067\u3042\u308b\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc(IC)\u304c\u591a\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u2192\u2192<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-basic\/?ICID=cmd_gc_r04_jp_gas_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u30a4\u30aa\u30f3\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e\u77e5\u8b58\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u5206\u91ce\u3054\u3068\u306e\u4e00\u822c\u7684\u306a\u5bfe\u8c61\u5316\u5408\u7269\u7fa4\u306e\u4e00\u4f8b\u3092\u4e0b\u8a18\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n<h4>\uff1c\u88fd\u85ac\u30fb\u533b\u85ac\u30fb\u30e1\u30bf\u30dc\u30ed\u30df\u30af\u30b9\uff1e<\/h4>\n<p>\u4f4e\u5206\u5b50\u533b\u85ac\u54c1\u3001\u539f\u85ac\u3001\u4e2d\u9593\u4f53\u3001\u533b\u85ac\u54c1\u4e2d\u6b8b\u7559\u6eb6\u5a92\u3001\u7cd6\u9396\u3001\u30a2\u30df\u30ce\u9178\u3001\u85ac\u7269\u4ee3\u8b1d\u7269\u3001\u30d0\u30a4\u30aa\u30de\u30fc\u30ab\u30fc\u3001\u30b7\u30a2\u30eb\u9178\u3001\u30aa\u30ea\u30b4\u7cd6\u3001\u8102\u8cea\u3001\u8102\u80aa\u9178\u3001\u8102\u80aa\u9178\u30e1\u30c1\u30eb\u30a8\u30b9\u30c6\u30eb\uff08FAME\uff09\u3001\u30a8\u30e9\u30b9\u30c8\u30de\u30fc<\/p>\n<h4>\uff1c\u98df\u54c1\u30fb\u98f2\u6599\uff1e<\/h4>\n<p>\u7cd6\u985e\u3001\u30d3\u30bf\u30df\u30f3\u3001\u6297\u751f\u7269\u8cea\u3001\u304b\u3073\u81ed\uff082,4,6-\u30c8\u30ea\u30af\u30ed\u30ed\u30a2\u30cb\u30bd\u30fc\u30eb\u3001\u30b8\u30a7\u30aa\u30b9\u30df\u30f3\u306a\u3069\uff09\u3001\u9999\u6599\u3001\u9999\u6c17\u6210\u5206\u3001\u7570\u81ed\u3001\u6b8b\u7559\u8fb2\u85ac\u3001\u30d5\u30bf\u30eb\u9178\u30a8\u30b9\u30c6\u30eb\u3001\u52d5\u7269\u7528\u533b\u85ac\u54c1\u3001\u6b8b\u7559\u8fb2\u85ac\u3001POPs\u3001\u30ab\u30d3\u6bd2\uff08\u30de\u30a4\u30b3\u30c8\u30ad\u30b7\u30f3\uff09\u3001\u98df\u54c1\u6dfb\u52a0\u7269\uff08\u7740\u8272\u6599\u3001\u67d3\u6599\u3001\u4eba\u5de5\u7518\u5473\u6599\u3001\u4fdd\u5b58\u6599\u306a\u3069\uff09\u3001\u9999\u8f9b\u6599\u3001\u8102\u80aa\u9178\u3001\u975e\u610f\u56f3\u7684\u6dfb\u52a0\u7269\u3001\u98df\u54c1\u5305\u88c5<\/p>\n<h4>\uff1c\u74b0\u5883\uff1e<\/h4>\n<p>\u30b4\u30eb\u30d5\u5834\u8fb2\u85ac\u3001\u9664\u8349\u5264\u3001POPs\u3001\u7121\u6a5f\u30a4\u30aa\u30f3\u3001\u7121\u6a5f\u9178\u3001\u6709\u6a5f\u9178\u3001\u533b\u85ac\u54c1\u304a\u3088\u3073\u30d1\u30fc\u30bd\u30ca\u30eb\u30b1\u30a2\u88fd\u54c1\uff08PPCP\uff09\u3001\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff08PFCs\uff09\u3001\u690d\u7269\u4ee3\u8b1d\u7269\u3001\u5929\u7136\u7269\u3001\u9ad8\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08VVOCs\uff09\u3001\u63ee\u767a\u6027\u5316\u5408\u7269\uff08VOCs\uff09\u3001\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\uff08SVOCs\uff09\u3001\u6b8b\u7559\u6027\u6709\u6a5f\u6c5a\u67d3\u7269\u8cea\uff08POPs\uff09\u3001\u30d5\u30e9\u30f3\u3001\u30dd\u30ea\u5869\u5316\u30d3\u30d5\u30a7\u30cb\u30eb\uff08PCBs\uff09\u3001\u30c0\u30a4\u30aa\u30ad\u30b7\u30f3\u3001\u6709\u6a5f\u30ea\u30f3\u7cfb\u8fb2\u85ac\u3001\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac<\/p>\n<h4>\uff1c\u6cd5\u533b\u30fb\u6bd2\u7269\uff1e<\/h4>\n<p>\u85ac\u7269\u3001\u30c7\u30b6\u30a4\u30ca\u30fc\u30c9\u30e9\u30c3\u30b0\u3001\u30c9\u30fc\u30d4\u30f3\u30b0\u95a2\u9023\uff08\u7981\u6b62\u7269\u8cea\u3001\u7981\u6b62\u85ac\u7269\u3001\u30b9\u30c6\u30ed\u30a4\u30c9\u306a\u3069\uff09\u3001\u4ee3\u8b1d\u7269\u3001\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3001\u30a2\u30f3\u30d5\u30a7\u30bf\u30df\u30f3<\/p>\n<h4>\uff1c\u5316\u5b66\u3001\u5de5\u696d\u3001\u77f3\u6cb9\u5316\u5b66\uff1e<\/h4>\n<p>\u30e2\u30ce\u30de\u30fc\u3001\u30dd\u30ea\u30de\u30fc\u3001\u6dfb\u52a0\u5264\u3001\u4e0d\u7d14\u7269\u3001\u6eb6\u5264\u3001BTEX\u3001\u7cbe\u6cb9\u3001\u30b7\u30ea\u30b3\u30f3\u3001\u5316\u7ca7\u54c1\u3001\u5316\u6210\u54c1\u3001\u539f\u6599\u3001\u53cd\u5fdc\u4e2d\u9593\u4f53\u3001\u53cd\u5fdc\u751f\u6210\u7269\u3001\u5408\u6210\u7269\u3001\u526f\u751f\u6210\u7269\u3001\u53ef\u5851\u5264\u3001\u30a4\u30f3\u30af\u3001\u30a8\u30f3\u30b8\u30f3\u30aa\u30a4\u30eb\u3001\u77f3\u6cb9\u3001\u30ca\u30d5\u30b5\u3001\u5929\u7136\u30ac\u30b9\u3001\u5de5\u696d\u7528\u6c34\u3001\u51b7\u5374\u6c34\u3001\u6d17\u6d44\u6c34\u3001\u70ad\u5316\u6c34\u7d20\u3001\u591a\u74b0\u82b3\u9999\u65cf\u70ad\u5316\u6c34\u7d20\uff08PAHs\uff09\u3001\u30d0\u30a4\u30aa\u30c7\u30a3\u30fc\u30bc\u30eb<\/p>\n<p>&nbsp;<\/p>\n<p>\u305d\u308c\u305e\u308c\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30c7\u30fc\u30bf\u306f\u4e0b\u8a18\u306eAppsLab Library\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u2192\u2192<a href=\"https:\/\/appslab.thermofisher.com?ICID=cmd_gc_r04_jp_gas_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">AppsLab Library\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>GC\u306e\u69cb\u6210<\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/8959ae5859d4dfb61049ee98975f913e.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-5979 size-full\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/8959ae5859d4dfb61049ee98975f913e.jpg\" alt=\"GC_Constitution\" width=\"960\" height=\"720\" \/><\/a><\/p>\n<p style=\"background: white;vertical-align: baseline\">GC\u306f\u305d\u306e\u6d41\u8def\u306e\u4e0a\u6d41\u304b\u3089\u3001\u4e0b\u8a18\u306e\u4e94\u3064\u306e\u30bb\u30af\u30b7\u30e7\u30f3\u306b\u3088\u308a\u69cb\u6210\u3055\u308c\u307e\u3059\u3002<\/p>\n<h4>\uff1c\u2460\u30ad\u30e3\u30ea\u30a2\u30fc\u30ac\u30b9\u6d41\u91cf\u5236\u5fa1\u90e8\u3068\u306f\uff1e<\/h4>\n<p>\u79fb\u52d5\u76f8\u306e\u5f79\u5272\u3068\u306a\u308b\u300c\u30ad\u30e3\u30ea\u30a2\u30fc\u30ac\u30b9\u300d\u306e\u5c0e\u5165\u91cf\u3092\u5236\u5fa1\u3059\u308b\u90e8\u5206\u3067\u3059\u3002\u5206\u6790\u306e\u518d\u73fe\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u3001\u3053\u306e\u30ad\u30e3\u30ea\u30a2\u30fc\u30ac\u30b9\u306f\u5f8c\u8ff0\u306e\u30ab\u30e9\u30e0\uff08\u56fa\u5b9a\u76f8\uff09\u3068\u547c\u3070\u308c\u308b\u5206\u96e2\u90e8\u306b\u300c\u6d41\u91cf\u300d\u3082\u3057\u304f\u306f\u300c\u5727\u529b\u300d\u304c\u4e00\u5b9a\u3068\u306a\u308b\u3088\u3046\u306b\u5c0e\u5165\u3055\u308c\u307e\u3059\u3002\u30ad\u30e3\u30ea\u30a2\u30fc\u30ac\u30b9\u306e\u30ac\u30b9\u6e90\u306f\u30ac\u30b9\u30dc\u30f3\u30d9\u304c\u901a\u4f8b\u3067\u3059\u3002<\/p>\n<h4>\uff1c\u2461\u8a66\u6599\u5c0e\u5165\u90e8\uff08\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u30fc\u30fb\u6ce8\u5165\u53e3\uff09\u3068\u306f\uff1e<\/h4>\n<p>\u8a66\u6599\uff08\u5206\u6790\u7a2e\uff09\u3092\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3059\u308b\u305f\u3081\u306e\u90e8\u5206\u3067\u3059\u3002\u3053\u3053\u306f\u30ad\u30e3\u30ea\u30a2\u30fc\u30ac\u30b9\u306e\u6d41\u8def\u306e\u4e2d\u306b\u5b58\u5728\u3057\u3066\u304a\u308a\u3001\u4e0a\u8ff0\u306e\u5236\u5fa1\u90e8\u3068\u5f8c\u8ff0\u306eGC\u30ab\u30e9\u30e0\u306e\u9593\u306b\u4f4d\u7f6e\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>GC\u306b\u304a\u3044\u3066\u3001\u5206\u6790\u7a2e\u304c\u5206\u96e2\u3055\u308c\u308b\u305f\u3081\u306b\u306f\u5fc5\u305a\u6c17\u4f53\u306e\u72b6\u614b\u3068\u306a\u3063\u3066\u3044\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u73fe\u5728\u4e3b\u6d41\u3068\u306a\u3063\u3066\u3044\u308bGC\u306e\u88c5\u7f6e\u306b\u306f\u6db2\u4f53\u8a66\u6599\u306a\u3069\u3092\u7cbe\u5ea6\u3088\u304f\u6c17\u5316\u3055\u305b\u308b\u305f\u3081\u306e\u300c\u8a66\u6599\u6c17\u5316\u5ba4\u300d\u304c\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u6c17\u5316\u5ba4\u306f\u6c17\u5316\u52b9\u7387\u3092\u9ad8\u3081\u308b\u305f\u3081\u306b\u9ad8\u6e29\u3068\u306a\u3063\u3066\u304a\u308a\u3001\u3055\u3089\u306b\u8a66\u6599\u304c\u63a5\u89e6\u3059\u308b\u6c17\u5316\u5ba4\u5185\u306e\u30ac\u30e9\u30b9\u88fd\u3001\u91d1\u5c5e\u88fd\u90e8\u5206\u3082\u8a66\u6599\u306e\u5438\u7740\u30fb\u5206\u89e3\u3092\u9632\u3050\u305f\u3081\u306b\u4e0d\u6d3b\u6027\u51e6\u7406\u304c\u65bd\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u8a66\u6599\u306e\u6ce8\u5165\u65b9\u6cd5\u3084\u30ab\u30e9\u30e0\u3078\u306e\u5c0e\u5165\u65b9\u6cd5\u3001\u3055\u3089\u306b\u9023\u7d9a\u5206\u6790\u6642\u306e\u518d\u73fe\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u306a\u3069\u306b\u3064\u3044\u3066\u306f\u5225\u306e\u8a18\u4e8b\u3067\u63b2\u8f09\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<h4>\uff1c\u2462\u5206\u96e2\u90e8\uff08\u30ab\u30e9\u30e0\uff09\u3068\u306f\uff1e<\/h4>\n<p>\u8a66\u6599\u5c0e\u5165\u90e8\u3067\u6ce8\u5165\u3055\u308c\u305f\u8a66\u6599\u3092\u5206\u96e2\u3059\u308b\u90e8\u5206\u3067\u3059\u3002GC\uff08\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff09\u30ab\u30e9\u30e0\u306e\u7a2e\u985e\u306f\u300c\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\uff08\u5145\u586b\u30ab\u30e9\u30e0\uff09\u300d\u3068\u300c\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u300d\u306e\uff12\u3064\u306b\u5927\u5225\u3055\u308c\u307e\u3059\u304c\u3001\u73fe\u5728\u3067\u306f\u9ad8\u3044\u5206\u96e2\u80fd\u3084\u5206\u6790\u306e\u8fc5\u901f\u6027\u304b\u3089\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u304c\u4e3b\u6d41\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306f\u56fa\u5b9a\u76f8\u306e\u5f79\u5272\u3092\u62c5\u3046\u300c\u6db2\u76f8\u300d\u306e\u7a2e\u985e\u3084\u305d\u306e\u819c\u539a\u3001\u307e\u305f\u30ab\u30e9\u30e0\u306e\u9577\u3055\u3084\u5185\u5f84\u306a\u3069\u306b\u3088\u308a\u81a8\u5927\u306a\u7a2e\u985e\u304c\u5b58\u5728\u3057\u3066\u304a\u308a\u3001\u5206\u6790\u8005\u306e\u76ee\u7684\u306b\u5fdc\u3058\u3066\u9078\u5b9a\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<p>\u30ab\u30e9\u30e0\u306f\u901a\u5e38\u3001\u30ab\u30e9\u30e0\u30aa\u30fc\u30d6\u30f3\u3068\u547c\u3070\u308c\u308b\u7b50\u4f53\u306b\u53ce\u7d0d\u3055\u308c\u3066\u3044\u307e\u3059\u3002GC\u3067\u306f\u5206\u6790\u4e2d\u306b\u30aa\u30fc\u30d6\u30f3\u306e\u6e29\u5ea6\u3092\u7d4c\u6642\u7684\u306b\u5909\u5316\u3055\u305b\u308b\u305f\u3081\u306e\u300c\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u300d\u3092\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u901a\u4f8b\u3067\u3059\u3002\u30ab\u30e9\u30e0\u306e\u6e29\u5ea6\u3092\u6bb5\u968e\u7684\u306b\u4e0a\u6607\u3055\u305b\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u4f4e\uff5e\u9ad8\u6cb8\u70b9\u306e\u5e45\u5e83\u3044\u5206\u6790\u7a2e\u3092\u77ed\u6642\u9593\u3067\u540c\u6642\u306b\u5206\u96e2\u30fb\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<h4>\uff1c\u2463\u691c\u51fa\u5668\u3068\u306f\uff1e<\/h4>\n<p>\u30ab\u30e9\u30e0\u3067\u5206\u96e2\u3055\u308c\u305f\u306e\u3061\u306e\u5206\u6790\u7a2e\u3092\u691c\u51fa\u3057\u307e\u3059\u3002\u691c\u51fa\u5668\u306f\u5f97\u3089\u308c\u305f\u30b7\u30b0\u30ca\u30eb\u3092PC\u306a\u3069\u306e\u30c7\u30fc\u30bf\u51e6\u7406\u90e8\u3078\u96fb\u6c17\u4fe1\u53f7\u3068\u3057\u3066\u9001\u4fe1\u3057\u307e\u3059\u3002\u691c\u51fa\u5668\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u7a2e\u985e\u304c\u5b58\u5728\u3057\u307e\u3059\u304c\u3001\u691c\u51fa\u306e\u539f\u7406\u3084\u5fdc\u7b54\u6027\u304c\u7570\u306a\u308b\u305f\u3081\u5206\u6790\u7a2e\u306b\u5fdc\u3058\u3066\u9078\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u822c\u7684\u306a\u691c\u51fa\u5668\u306b\u306fFID\u3001TCD\u3001NPD\u3001FPD\u304c\u3042\u308a\u3001\u7279\u306bFID\u306f\u6c4e\u7528\u6027\u304c\u9ad8\u3044\u305f\u3081\u6700\u3082\u666e\u53ca\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u5206\u6790\u7a2e\u306e\u8cea\u91cf\u306b\u57fa\u3065\u3044\u3066\u5206\u96e2\u3001\u5b9a\u6027\u3001\u5b9a\u91cf\u304c\u53ef\u80fd\u306a\u8cea\u91cf\u5206\u6790\u8a08\uff08mass spectrometry : \uff1aMS\uff09\u3082\u591a\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u305d\u306e\u5185\u90e8\u6a5f\u69cb\u306b\u3088\u3063\u3066\u30b7\u30f3\u30b0\u30eb\u56db\u91cd\u6975\u3001\u30c8\u30ea\u30d7\u30eb\u56db\u91cd\u6975\u3001\u4e8c\u91cd\u53ce\u675f\u578b\u3001\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc \u306a\u3069\u306b\u5206\u985e\u3055\u308c\u307e\u3059\u3002<\/p>\n<h4>\uff1c\u2464\u30c7\u30fc\u30bf\u51e6\u7406\u90e8\u3068\u306f\uff1e<\/h4>\n<p>PC\u3068\u30c7\u30fc\u30bf\u89e3\u6790\u7528\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3092\u5229\u7528\u3057\u3001\u691c\u51fa\u5668\u304b\u3089\u53d7\u4fe1\u3057\u305f\u30b7\u30b0\u30ca\u30eb\u3092\u89e3\u6790\u30fb\u51fa\u529b\u3059\u308b\u90e8\u5206\u3067\u3059\u3002\u5206\u6790\u8005\u306fGC\u306b\u3088\u308a\u5f97\u3089\u308c\u305f\u5206\u96e2\u306e\u7d50\u679c\u3092\u300c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u300d\u3084\u30b9\u30da\u30af\u30c8\u30eb\u3068\u3057\u3066\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>GC\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf<\/h2>\n<p>GC\u3067\u306f\u3001\u5f97\u3089\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e2d\u306b\u73fe\u308c\u305f\u30d4\u30fc\u30af\u306e\u6eb6\u51fa\u6642\u9593\u3068\u305d\u306e\u9762\u7a4d\u5024\u306b\u3088\u308a\u3001\u5206\u6790\u7a2e\u306e\u5b9a\u6027\u3068\u5b9a\u91cf\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<p>\u30fb\u5b9a\u6027\uff1a\u300c\u5206\u6790\u7a2e\u306e\u30d4\u30fc\u30af\u306e\u6eb6\u51fa\u6642\u9593\u300d<\/p>\n<p>\u30fb\u5b9a\u91cf\uff1a\u300c\u5206\u6790\u7a2e\u306e\u30d4\u30fc\u30af\u306e\u5927\u304d\u3055\uff08\u9762\u7a4d\u5024\u3001\u7a4d\u5206\u5024\uff09\u300d<\/p>\n<p>&nbsp;<\/p>\n<p>\u3053\u3053\u3067\u306f\u3001\u5206\u6790\u7a2e\u56fa\u6709\u306e\u6027\u8cea\u3092\u5229\u7528\u3057\u3066\u5206\u96e2\u3092\u9054\u6210\u3057\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001GC\u306e\u5206\u6790\u6761\u4ef6\uff08\u8a66\u6599\u5c0e\u5165\u90e8\u3001\u30ab\u30e9\u30e0\u3001\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3001\u88c5\u7f6e\u6761\u4ef6\u3001\u8a66\u6599\u306a\u3069\uff09\u304c\u4e00\u5b9a\u3067\u3042\u308c\u3070\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u306f\u7279\u5b9a\u306e\u5206\u6790\u7a2e\u304c\u5e38\u306b\u540c\u3058\u6eb6\u51fa\u6642\u9593\u306b\u30d4\u30fc\u30af\u3068\u3057\u3066\u73fe\u308c\u307e\u3059\u3002\u3053\u308c\u3092\u5229\u7528\u3057\u3001\u672a\u77e5\u8a66\u6599\u4e2d\u306e\u5206\u6790\u7a2e\u306e\u5b9a\u6027\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u8a66\u6599\u306b\u3088\u3063\u3066\u306f\u76ee\u7684\u306e\u5206\u6790\u7a2e\u3068\u985e\u4f3c\u306e\u5316\u5b66\u7684\u7279\u6027\u3092\u6709\u3059\u308b\u5316\u5b66\u7a2e\u304c\u6df7\u5728\u3057\u3066\u3044\u308b\u3053\u3068\u3082\u3042\u308a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e0a\u3067\u5341\u5206\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u306a\u3044\u3053\u3068\u3082\u3057\u3070\u3057\u3070\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u3088\u3046\u306a\u5834\u5408\u306f\u5b9a\u6027\u30fb\u5b9a\u91cf\u304c\u56f0\u96e3\u306b\u306a\u308a\u307e\u3059\u306e\u3067\u3001\u9069\u5b9cGC\u306e\u5206\u6790\u6761\u4ef6\u3092\u5909\u66f4\u3001\u3042\u308b\u3044\u306f\u8cea\u91cf\u5206\u6790\u8a08\u306a\u3069\u306e\u9078\u629e\u6027\u304c\u9ad8\u3044\u691c\u51fa\u5668\u3092\u4f7f\u7528\u3059\u308b\u306a\u3069\u306e\u6700\u9069\u5316\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>GC\u306e\u30ab\u30e9\u30e0\u5206\u96e2\u3068\u691c\u51fa\u307e\u3067\u306e\u30a4\u30e1\u30fc\u30b8\u3092\u3064\u304b\u3080\u305f\u3081\u3001\u30a2\u30cb\u30e1\u30fc\u30b7\u30e7\u30f3\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>GC\u306e\u6e2c\u5b9a\u6fc3\u5ea6\u7bc4\u56f2<\/h2>\n<p>GC\u306b\u304a\u3051\u308b\u6e2c\u5b9a\u6fc3\u5ea6\u306e\u7bc4\u56f2\u306f\u691c\u51fa\u5668\u306b\u5927\u304d\u304f\u4f9d\u5b58\u3057\u307e\u3059\u3002\u691c\u51fa\u5668\u306f\u305d\u306e\u6e2c\u5b9a\u539f\u7406\u306b\u3088\u308a\u3001\u5206\u6790\u7a2e\u306b\u5bfe\u3059\u308b\u5fdc\u7b54\u306e\u7279\u7570\u6027\u3084\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u8a66\u6599\u306e\u6027\u72b6\u3084\u5206\u6790\u7a2e\u306e\u5b58\u5728\u91cf\u3001\u72d9\u3044\u3068\u3059\u308b\u691c\u51fa\u7bc4\u56f2\u306b\u5fdc\u3058\u3066\u9078\u5b9a\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u691c\u51fa\u5668\u3067\u306e\u5fdc\u7b54\u6027\u3092\u5897\u5927\u3055\u305b\u308b\u305f\u3081\u306b\u3001\u8a66\u6599\u6ce8\u5165\u524d\u306b\u5206\u6790\u7a2e\u306e\u8a98\u5c0e\u4f53\u5316\u3084\u6fc3\u7e2e\u30fb\u5e0c\u91c8\u3001\u593e\u96d1\u6210\u5206\u306e\u9664\u53bb\u306a\u3069\u3092\u884c\u3046\u300c\u8a66\u6599\u524d\u51e6\u7406\u300d\u3068\u3088\u3070\u308c\u308b\u64cd\u4f5c\u3082\u4e00\u822c\u7684\u306b\u3088\u304f\u7528\u3044\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u6e2c\u5b9a\u53ef\u80fd\u306a\u6fc3\u5ea6\u7bc4\u56f2\u306f\u30ab\u30e9\u30e0\u306b\u3088\u3063\u3066\u3082\u6c7a\u5b9a\u3055\u308c\u307e\u3059\u3002\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u5185\u5f84\u3084\u9577\u3055\u3001\u6db2\u76f8\u306e\u819c\u539a\u306a\u3069\u306b\u3088\u308a\u5206\u96e2\u6319\u52d5\u306f\u5927\u304d\u304f\u5909\u5316\u3057\u307e\u3059\u3002\u76ee\u7684\u306e\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u30ab\u30e9\u30e0\u3082\u5341\u5206\u306b\u691c\u8a0e\u3057\u9078\u629e\u3092\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n<h2>GC\u3067\u6e2c\u5b9a\u3067\u304d\u308b\u8a66\u6599<\/h2>\n<p>GC\u3067\u306f\u3001\u63ee\u767a\u6027\u304c\u3042\u308a\u3001\u71b1\u306b\u5b89\u5b9a\u306a\u5206\u6790\u7a2e\u304c\u6e2c\u5b9a\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u4e0a\u8ff0\u306e\u901a\u308a\u3001GC\u3067\u306f\u8a66\u6599\u3092\u6c17\u5316\u3055\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u5206\u5b50\u91cf1000\u4ee5\u4e0b\u3001\u6cb8\u70b9500\u2103\u4ee5\u4e0b\u306e\u7269\u6027\u3092\u6709\u3059\u308b\u5316\u5408\u7269\u3092\u76ee\u5b89\u3068\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001GC\u3092\u69cb\u6210\u3059\u308b\u8a66\u6599\u6ce8\u5165\u53e3\u3084\u30ab\u30e9\u30e0\u3001\u691c\u51fa\u5668\u306a\u3069\u306f\u9ad8\u6e29\u306b\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u5206\u6790\u7a2e\u304c\u3053\u308c\u3089\u306e\u71b1\u306b\u3088\u308a\u5206\u89e3\u3001\u91cd\u5408\u3057\u3066\u3057\u307e\u3046\u5834\u5408\u306b\u306f\u5b9a\u6027\u30fb\u5b9a\u91cf\u304c\u56f0\u96e3\u3068\u306a\u308a\u307e\u3059\u3002GC\u3067\u306e\u5206\u6790\u306e\u524d\u306b\u306f\u5206\u6790\u7a2e\u306e\u6cb8\u70b9\u3084\u5206\u5b50\u91cf\u3060\u3051\u3067\u306a\u304f\u3001\u71b1\u306b\u5bfe\u3059\u308b\u5b89\u5b9a\u6027\u306b\u3064\u3044\u3066\u3082\u78ba\u8a8d\u3057\u305f\u307b\u3046\u304c\u826f\u3044\u3067\u3057\u3087\u3046\u3002<\/p>\n<p>GC\u3067\u5206\u6790\u3059\u308b\u8a66\u6599\u306e\u72b6\u614b\u306f\u6c17\u4f53\u3068\u6db2\u4f53\u306e\u4e8c\u3064\u304c\u4e00\u822c\u7684\u3067\u3001\u56fa\u4f53\u8a66\u6599\u306e\u5834\u5408\u306b\u306f\u62bd\u51fa\u3084\u6eb6\u89e3\u3001\u5206\u89e3\u306a\u3069\u306e\u8a66\u6599\u524d\u51e6\u7406\u64cd\u4f5c\u3067\u8a66\u6599\u306e\u6eb6\u6db2\u5316\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u3053\u3067\u7528\u3044\u308b\u6eb6\u5a92\u306f\u63ee\u767a\u6027\u304c\u9ad8\u304f\u3001\u8a66\u6599\u306e\u6eb6\u89e3\u529b\u306b\u3082\u512a\u308c\u305f\u30a2\u30bb\u30c8\u30f3\u306a\u3069\u304c\u597d\u9069\u3067\u3059\u3002\u6c17\u4f53\u8a66\u6599\u306e\u5834\u5408\u3001\u6355\u96c6\u3057\u305f\u4e00\u5b9a\u91cf\u306e\u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\u3092GC\u306b\u6ce8\u5165\u3057\u3066\u5206\u6790\u3092\u884c\u3044\u308b\u305f\u3081\u3001\u8a66\u6599\u6ce8\u5165\u306b\u306f\u6c17\u5bc6\u6027\u306b\u512a\u308c\u305f\u30ac\u30b9\u30bf\u30a4\u30c8\u30b7\u30ea\u30f3\u30b8\u3092\u7528\u3044\u307e\u3059\u3002\u6628\u4eca\u3067\u306f\u6db2\u4f53\u3084\u56fa\u4f53\u306e\u8a66\u6599\u3092\u5bb9\u5668\u306b\u5165\u308c\u3066\u5bc6\u9589\u30fb\u52a0\u6e29\u3057\u3001\u305d\u3053\u304b\u3089\u767a\u751f\u3057\u305f\u30ac\u30b9\u3092\u63a1\u53d6\u3059\u308b\u300c\u30d8\u30c3\u30c9\u30b9\u30da\u30fc\u30b9\u6cd5\u300d\u3082\u591a\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>GC\u3092\u7528\u3044\u3066\u9ad8\u6975\u6027\u30fb\u96e3\u63ee\u767a\u6027\u306e\u5206\u6790\u7a2e\u3092\u6e2c\u5b9a\u3057\u305f\u3044\u3068\u304d\u306b\u306f\u3001\u8a66\u6599\u306e\u8a98\u5c0e\u4f53\u5316\u3092\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u8a98\u5c0e\u4f53\u5316\u3068\u306f\u3001\u5206\u6790\u7a2e\u306e\u5206\u5b50\u69cb\u9020\u3092\u5909\u5316\u3055\u305b\u308b\u5316\u5b66\u4fee\u98fe\u53cd\u5fdc\u3092\u6307\u3057\u307e\u3059\u3002GC\u5206\u6790\u306b\u304a\u3051\u308b\u8a98\u5c0e\u4f53\u5316\u306e\u591a\u304f\u304c\u6c17\u5316\u52b9\u7387\u306e\u6539\u5584\u3092\u76ee\u7684\u3068\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u53e4\u5178\u7684\u306a\u8a98\u5c0e\u4f53\u5316\u624b\u6cd5\u3067\u306f\u30cf\u30f3\u30c9\u30ea\u30f3\u30b0\u304c\u8907\u96d1\u3067\u3001\u8a98\u5c0e\u4f53\u5316\u52b9\u7387\u3082\u554f\u984c\u3068\u306a\u308b\u3053\u3068\u3042\u308a\u307e\u3059\u3002\u30d3\u30ae\u30ca\u30fc\u306e\u65b9\u3005\u306b\u306fThermo Scientific\u2122 GC \u8a66\u85ac\u304c\u304a\u85a6\u3081\u3067\u3059\u3002\u3053\u306e\u8a66\u85ac\u306f\u30e9\u30a4\u30f3\u30ca\u30c3\u30d7\u304c\u8c4a\u5bcc\u306a\u305f\u3081\u3001\u69d8\u3005\u306a\u5206\u6790\u7a2e\u306b\u5bfe\u3057\u8a66\u85ac\u304c\u6700\u9069\u5316\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u8a66\u85ac\u3054\u3068\u306b\u64cd\u4f5c\u306e\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\u304c\u8a73\u7d30\u306b\u8a18\u8f09\u3055\u308c\u3066\u304a\u308a\u307e\u3059\u306e\u3067\u3001\u30cf\u30f3\u30c9\u30ea\u30f3\u30b0\u3082\u5bb9\u6613\u306b\u884c\u3048\u307e\u3059\u3002GC\u5206\u6790\u306e\u524d\u306b\u306f\u8a98\u5c0e\u4f53\u5316\u3082\u8996\u91ce\u306b\u5165\u308c\u3066\u691c\u8a0e\u3057\u3066\u3044\u304f\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n<p>\u2192<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/gas-chromatography-gc\/gc-reagents.html?ICID=cmd_gc_r04_jp_gas_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">Thermo Scientific\u2122 GC \u8a66\u85ac\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>GC\u306e\u6e2c\u5b9a\u6642\u9593<\/h2>\n<p>\u5206\u6790\u6642\u9593\u306b\u3064\u3044\u3066\u306f\u4e00\u822c\u7684\u306b\u6570\u5206\uff5e\uff11\u6642\u9593\u7a0b\u5ea6\u304c\u901a\u4f8b\u3067\u3059\u304c\u3001\u5206\u6790\u8005\u306e\u76ee\u7684\u3084\u5fc5\u8981\u3068\u3059\u308b\u5206\u6790\u611f\u5ea6\u3001\u7cbe\u5ea6\u3001\u5206\u6790\u7a2e\u306e\u6570\u306a\u3069\u306b\u3088\u308a\u5927\u304d\u304f\u5909\u5316\u3057\u307e\u3059\u3002HPLC\u3088\u308a\u3082\u6bd4\u8f03\u7684\u5206\u6790\u6642\u9593\u304c\u9577\u3044\u4e8b\u4f8b\u3082\u591a\u3044\u306e\u3067\u3059\u304c\u3001Thermo Scientific\u2122 TraceGOLD\u2122GC\u30ab\u30e9\u30e0\u30b7\u30ea\u30fc\u30ba\u306b\u306f\u5206\u6790\u5bfe\u8c61\u306b\u5fdc\u3058\u3066\u6700\u9069\u306a\u6db2\u76f8\u304c\u6570\u591a\u304f\u30e9\u30a4\u30f3\u30ca\u30c3\u30d7\u3055\u308c\u3066\u304a\u308a\u307e\u3059\u306e\u3067\u3001\u3053\u308c\u3089\u306e\u30ab\u30e9\u30e0\u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u52b9\u7387\u7684\u306a\u5206\u6790\u304c\u884c\u3048\u3001\u7d50\u679c\u7684\u306b\u6642\u9593\u306e\u5927\u5e45\u306a\u77ed\u7e2e\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n<p>\u2192\u2192<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/chromatography\/gas-chromatography-gc\/gc-columns.html?ICID=cmd_gc_r04_jp_gas_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u30ab\u30e9\u30e0\u306f\u3053\u3061\u3089<\/a><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>GC\u306f\u5206\u6790\u5024\u306e\u7cbe\u5ea6\u3084\u691c\u51fa\u611f\u5ea6\u3001\u6c4e\u7528\u6027\u3001\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306a\u3069\u6570\u591a\u304f\u306e\u30a2\u30c9\u30d0\u30f3\u30c6\u30fc\u30b8\u3092\u6709\u3059\u308b\u5206\u6790\u624b\u6cd5\u3067\u3001\u7279\u306b\u63ee\u767a\u6027\u6210\u5206\u306e\u5b9a\u6027\u30fb\u5b9a\u91cf\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>GC\u3092\u4e0a\u624b\u306b\u4f7f\u3046\u305f\u3081\u306b\u306f\u3001GC\u306e\u88c5\u7f6e\u3084\u30ab\u30e9\u30e0\u3001\u8a98\u5c0e\u4f53\u5316\u306b\u7528\u3044\u308b\u8a66\u85ac\u306a\u3069\u306e\u6700\u9069\u5316\u304c\u975e\u5e38\u306b\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u7279\u306b\u8a98\u5c0e\u4f53\u5316\u3084\u8a66\u6599\u6ce8\u5165\u53e3\u6761\u4ef6\u3001\u30ab\u30e9\u30e0\u306e\u7a2e\u985e\u306e\u8a2d\u5b9a\u306f\u5206\u6790\u306e\u53ef\u5426\u3092\u6c7a\u5b9a\u3059\u308b\u305f\u3081\u3001\u5206\u6790\u306e\u76ee\u7684\u306b\u5fdc\u3058\u3066\u6700\u9069\u5316\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u6b21\u56de\u4ee5\u964d\u3067\u306f\u30ab\u30e9\u30e0\u3084\u5206\u6790\u6761\u4ef6\u306e\u6700\u9069\u5316\u306b\u3064\u3044\u3066\u3082\u8aac\u660e\u3092\u3057\u3066\u3044\u304d\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306e\u8a18\u4e8b\u306f\u3044\u304b\u304c\u3067\u3057\u3087\u3046\u304b\u3002PDF\u7248\u306f\u4e0b\u8a18\u306e\u30ea\u30f3\u30af\u3088\u308a\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/072420-gc-basic-article.html?ICID=cmd_gc_r04_jp_gas_chromatography_Social_LAB\" target=\"_blank\" rel=\"noopener\">PDF\u7248\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089\u304b\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>GC (\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff09\u3068\u306f\uff1f GC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08Gas Chromatography\uff09\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3001HPLC\uff08\u9ad8\u901f\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff09\u3068\u4e26\u3073\u3082\u3063\u3068\u3082\u30dd\u30d4\u30e5\u30e9\u30fc\u306a\u5b9a\u6027\u30fb\u5b9a\u91cf<\/p>\n","protected":false},"author":988,"featured_media":5191,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[],"division":[],"class_list":{"0":"post-1588","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-analysis","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>GC\u3068\u306f\uff1f\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"GC\u3068\u306f\uff1fGC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u691c\u51fa\u5668\u3084\u30ab\u30e9\u30e0\u306a\u3069GC\u3092\u69cb\u6210\u3059\u308b\u90e8\u54c1\u306e\u7a2e\u985e\u306a\u3069\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4f7f\u3044\u65b9\u306b\u95a2\u3059\u308b\u57fa\u790e\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044GC\u306e\u57fa\u790e\" \/>\n<meta property=\"og:description\" content=\"GC\u3068\u306f\uff1fGC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u691c\u51fa\u5668\u3084\u30ab\u30e9\u30e0\u306a\u3069GC\u3092\u69cb\u6210\u3059\u308b\u90e8\u54c1\u306e\u7a2e\u985e\u306a\u3069\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4f7f\u3044\u65b9\u306b\u95a2\u3059\u308b\u57fa\u790e\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2019-05-21T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-15T02:55:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"16\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044GC\u306e\u57fa\u790e\",\"datePublished\":\"2019-05-21T15:00:00+00:00\",\"dateModified\":\"2023-08-15T02:55:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/\"},\"wordCount\":114,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1photo.jpg\",\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/\",\"name\":\"GC\u3068\u306f\uff1f\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1photo.jpg\",\"datePublished\":\"2019-05-21T15:00:00+00:00\",\"dateModified\":\"2023-08-15T02:55:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"description\":\"GC\u3068\u306f\uff1fGC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u691c\u51fa\u5668\u3084\u30ab\u30e9\u30e0\u306a\u3069GC\u3092\u69cb\u6210\u3059\u308b\u90e8\u54c1\u306e\u7a2e\u985e\u306a\u3069\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4f7f\u3044\u65b9\u306b\u95a2\u3059\u308b\u57fa\u790e\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1photo.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/H1photo.jpg\",\"width\":1200,\"height\":630,\"caption\":\"GC\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/gas_chromatography\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044GC\u306e\u57fa\u790e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"GC\u3068\u306f\uff1f\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e - Learning at the Bench","description":"GC\u3068\u306f\uff1fGC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u691c\u51fa\u5668\u3084\u30ab\u30e9\u30e0\u306a\u3069GC\u3092\u69cb\u6210\u3059\u308b\u90e8\u54c1\u306e\u7a2e\u985e\u306a\u3069\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4f7f\u3044\u65b9\u306b\u95a2\u3059\u308b\u57fa\u790e\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/","og_locale":"ja_JP","og_type":"article","og_title":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044GC\u306e\u57fa\u790e","og_description":"GC\u3068\u306f\uff1fGC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u691c\u51fa\u5668\u3084\u30ab\u30e9\u30e0\u306a\u3069GC\u3092\u69cb\u6210\u3059\u308b\u90e8\u54c1\u306e\u7a2e\u985e\u306a\u3069\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4f7f\u3044\u65b9\u306b\u95a2\u3059\u308b\u57fa\u790e\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2019-05-21T15:00:00+00:00","article_modified_time":"2023-08-15T02:55:29+00:00","og_image":[{"width":1200,"height":630,"url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"16\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044GC\u306e\u57fa\u790e","datePublished":"2019-05-21T15:00:00+00:00","dateModified":"2023-08-15T02:55:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/"},"wordCount":114,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo.jpg","articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/","name":"GC\u3068\u306f\uff1f\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u57fa\u790e - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo.jpg","datePublished":"2019-05-21T15:00:00+00:00","dateModified":"2023-08-15T02:55:29+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"description":"GC\u3068\u306f\uff1fGC\u306f\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u7565\u3067\u3059\u3002\u65e5\u672c\u3067\u306f\u30ac\u30b9\u30af\u30ed\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u691c\u51fa\u5668\u3084\u30ab\u30e9\u30e0\u306a\u3069GC\u3092\u69cb\u6210\u3059\u308b\u90e8\u54c1\u306e\u7a2e\u985e\u306a\u3069\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4f7f\u3044\u65b9\u306b\u95a2\u3059\u308b\u57fa\u790e\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u8aac\u660e\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo.jpg","width":1200,"height":630,"caption":"GC"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/gas_chromatography\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u77e5\u3063\u3066\u304a\u304d\u305f\u3044GC\u306e\u57fa\u790e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":105,"filter":"raw","meta":[],"cat_ID":157,"category_count":105,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":25090,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-elemental-analysis-csm-26016\/","url_meta":{"origin":1588,"position":0},"title":"\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u88fd\u9020\uff1a\u4f7f\u7528\u3055\u308c\u308b\u5316\u5b66\u5206\u6790\u6280\u8853","author":"LatB Staff","date":"2026\u5e744\u670820\u65e5","format":false,"excerpt":"\u9ad8\u6027\u80fd\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u6025\u5897\u306f\u3001\u751f\u7523\u306e\u3042\u3089\u3086\u308b\u6bb5\u968e\u306b\u304a\u3051\u308b\u5927\u898f\u6a21\u306a\u6295\u8cc7\u3092\u4fc3\u3057\u3066\u3044\u307e\u3059\u3002\u96fb\u6c60\u7814\u7a76\u304a\u3088\u3073\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/battery-development-elemental-analysis-csm-26016_eyecatch.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":24614,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-elemental-analysis-csm-26005\/","url_meta":{"origin":1588,"position":1},"title":"\u96fb\u6c60\u30ea\u30b5\u30a4\u30af\u30eb\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2026\u5e741\u670827\u65e5","format":false,"excerpt":"\u81ea\u52d5\u8eca\u306e\u96fb\u52d5\u5316\u3068\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u306e\u8caf\u8535\u80fd\u529b\u306e\u5897\u52a0\u306f\u3001\u3068\u3082\u306b\u96fb\u6c60\u306b\u5bfe\u3059\u308b\u9700\u8981\u306e\u5927\u5e45\u306a\u52a0\u901f\u3092\u3082\u305f\u3089\u3057\u3066\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-manufacturing-elemental-analysis-csm-26005_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25592,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ion-chromatography-contaminant-analysis-cmd-26024\/","url_meta":{"origin":1588,"position":2},"title":"\u5316\u7ca7\u54c1\u4e2d\u306ePFAS\u5206\u6790\u3068\u306f\uff1f\u7dcf\u6709\u6a5f\u30d5\u30c3\u7d20\uff08TOF\uff09\u6e2c\u5b9a\u306b\u3088\u308b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3068\u898f\u5236\u5bfe\u5fdc","author":"LatB Staff","date":"2026\u5e749\u670810\u65e5","format":false,"excerpt":"PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u306f\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\uff08Forever Chemicals\uff09\u300d\u3068\u3082\u547c\u3070\u308c\u3001\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/ion-chromatography-contaminant-analysis-cmd-26024_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24408,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elemental-analysis-case-introduction-cmd-25076\/","url_meta":{"origin":1588,"position":3},"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u7c89\u672b\u8a66\u6599\u306e\u8fc5\u901f\u30fb\u9ad8\u611f\u5ea6\u306a\u5143\u7d20\u5206\u6790","author":"LatB Staff","date":"2025\u5e7412\u670812\u65e5","format":false,"excerpt":"\u5316\u5b66\u54c1\u3084\u5de5\u696d\u6750\u6599\u306e\u539f\u6599\u3001\u304a\u3088\u3073\u4e8c\u6b21\u96fb\u6c60\u5411\u3051\u306e\u6a5f\u80fd\u6027\u6750\u6599\u306a\u3069\u3001\u7c89\u672b\u8a66\u6599\u3084\u30bb\u30e9\u30df\u30c3\u30af\u30b9\u6750\u6599\u4e2d\u306e\u5fae\u91cf\u5143\u7d20\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/shutterstock_2249094135-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24462,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url_meta":{"origin":1588,"position":4},"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","author":"LatB Staff","date":"2025\u5e7412\u670817\u65e5","format":false,"excerpt":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25362,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-ion-chromatography-csm-26020\/","url_meta":{"origin":1588,"position":5},"title":"IC-MS\/MS\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u8ca0\u6975\u306e\u52a3\u5316\u89e3\u6790","author":"LatB Staff","date":"2026\u5e746\u670826\u65e5","format":false,"excerpt":"\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Lithium-Ion Battery Anode Degrada\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/battery-development-ion-chromatography-csm-26020_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/H1photo.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1588","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=1588"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/1588\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/5191"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=1588"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=1588"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=1588"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=1588"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}