{"id":15898,"date":"2023-12-19T10:19:24","date_gmt":"2023-12-19T01:19:24","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=15898"},"modified":"2025-07-02T16:53:45","modified_gmt":"2025-07-02T07:53:45","slug":"basic-workshop-gsd-ts-3","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089"},"content":{"rendered":"<p>\u30d0\u30a4\u30aa\u5b9f\u9a13\u3067\u306f\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6db2\u4f53\u8a66\u85ac\u3092\u6df7\u5408\u3059\u308b\u3053\u3068\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u53cd\u5fdc\u3092\u9032\u3081\u307e\u3059\u3002\u6df7\u5408\u65b9\u6cd5\u306b\u306f\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u4ed6\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3084\u30bf\u30c3\u30d4\u30f3\u30b0\u3001\u8ee2\u5012\u6df7\u548c\u306a\u3069\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u9175\u7d20\u6d3b\u6027\u3078\u306e\u5f71\u97ff\u304c\u6c17\u306b\u306a\u308b\u5834\u9762\u3067\u306f\u3001\u6bd4\u8f03\u7684\u7a4f\u3084\u304b\u306b\u6df7\u5408\u3067\u304d\u308b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u9078\u629e\u3055\u308c\u308b\u65b9\u3082\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tr-workshop-gsd-ts-1\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u904e\u53bb\u306e\u30d6\u30ed\u30b0<\/a>\u3067\u306f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u30b3\u30c4\u3092\u52d5\u753b\u306b\u3057\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u304c\u3001\u5b9f\u969b\u306e\u5b9f\u9a13\u7d50\u679c\u306b\u306f\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u5236\u9650\u9175\u7d20\u51e6\u7406\u306b\u3064\u3044\u3066\u3084\u3063\u3066\u307f\u307e\u3057\u305f\u3002<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tr-workshop-gsd-ts-1\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u904e\u53bb\u30d6\u30ed\u30b0<\/a>\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u52d5\u753b\u3082\u5408\u308f\u305b\u3066\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u6750\u6599\u3068\u65b9\u6cd5<\/h2>\n<p>\u5236\u9650\u9175\u7d20\u51e6\u7406\u3059\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3057\u3066\u30011042 bp\u306ePCR\u7523\u7269\u3092\u7528\u610f\u3057\u307e\u3057\u305f\u3002\u3053\u306ePCR\u7523\u7269\u306b\u306f\u3001\u5236\u9650\u9175\u7d20Hind III\u306e\u8a8d\u8b58\u30b5\u30a4\u30c8\u304c1\u30ab\u6240\u3060\u3051\u3042\u308a\u3001\u6b63\u3057\u304f\u51e6\u7406\u3055\u308c\u308c\u3070651 bp\u3068397 bp\u306e2\u3064\u306e\u65ad\u7247\u306b\u5207\u65ad\u3055\u308c\u308b\u306f\u305a\u3067\u3059\uff08\u56f31\uff09\u3002<\/p>\n<div id=\"attachment_15900\" style=\"width: 618px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15900\" class=\"size-large wp-image-15900\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_01-1024x550.jpg\" alt=\"\u56f31. \u5236\u9650\u9175\u7d20\u51e6\u7406\u5b9f\u9a13\u306b\u7528\u3044\u305fDNA\" width=\"608\" height=\"326\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_01-1024x550.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_01-300x161.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_01-768x413.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_01.jpg 1115w\" sizes=\"auto, (max-width: 608px) 100vw, 608px\" \/><p id=\"caption-attachment-15900\" class=\"wp-caption-text\">\u56f31. \u5236\u9650\u9175\u7d20\u51e6\u7406\u5b9f\u9a13\u306b\u7528\u3044\u305fDNA<\/p><\/div>\n<p>\u5236\u9650\u9175\u7d20\u306e\u53cd\u5fdc\u6db2\u7d44\u6210\u306f\u88681\u306e\u901a\u308a\u3067\u3059\u3002\u5236\u9650\u9175\u7d20\u4ee5\u5916\u306e\u5171\u901a\u90e8\u5206\u306f\u307e\u3068\u3081\u3066\u8abf\u88fd\u3057\u3001\u6700\u5f8c\u306bHind III \u3082\u3057\u304f\u306fNuclease-Free Water\u3092\u6dfb\u52a0\u3057\u3066\u6df7\u5408\u3057\u307e\u3057\u305f\uff08\u88681\uff09\u3002<\/p>\n<table style=\"border-collapse: collapse;border-color: silver\" border=\"2\">\n<caption><b>\u88681\u3000\u5236\u9650\u9175\u7d20\u306e\u53cd\u5fdc\u6db2\u306e\u7d44\u6210<\/b><\/caption>\n<tbody>\n<tr bgcolor=\"white\">\n<td style=\"text-align: center\" width=\"60\">Nuclease-Free Water<\/td>\n<td style=\"text-align: center\" width=\"60\">15 \u00b5L<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"60\">Anza 10\u00d7 Buffer<\/td>\n<td style=\"text-align: center\" width=\"60\">2 \u00b5L<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"60\">PCR \u7523\u7269<\/td>\n<td style=\"text-align: center\" width=\"60\">2 \u00b5L<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"60\">Hind III or Nuclease-Free Water<\/td>\n<td style=\"text-align: center\" width=\"60\">1 \u00b5L<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"60\">Total<\/td>\n<td style=\"text-align: center\" width=\"60\">20 \u00b5L<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u5236\u9650\u9175\u7d20\u306b\u3088\u308bDNA\u5207\u65ad\u306b\u3064\u3044\u3066\u3001\u6df7\u5408\u7a0b\u5ea6\u306b\u3088\u308b\u5f71\u97ff\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u30014\u3064\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u6761\u4ef6\uff08\u88682\uff09\u3067\u6df7\u5408\u3057\u3066\u304b\u3089\u5236\u9650\u9175\u7d20\u51e6\u7406\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u88682\u306e\u300c\u30d4\u30da\u30c3\u30c8\u5bb9\u91cf\u300d\u306b\u8abf\u6574\u3057\u305f\u30d4\u30da\u30c3\u30c8\u3092\u6e96\u5099\u3057\u3001\u6761\u4ef61\u306fHind III\u306e\u4ee3\u308f\u308a\u306bNuclease-Free Water\u3092\u4f7f\u7528\u3057\u305f\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3001\u6761\u4ef62\u306f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u305c\u308b\u901a\u5e38\u6761\u4ef6\u3001\u6761\u4ef63\u306f\u5c11\u306a\u3059\u304e\u308b\u5bb9\u91cf\u3067\u6df7\u305c\u308b\u6761\u4ef6\u3001\u305d\u3057\u3066\u6761\u4ef64\u306f\u5168\u304f\u6df7\u305c\u306a\u304b\u3063\u305f\u5834\u5408\u3067\u3059\u3002\u9175\u7d20\u53cd\u5fdc\u3092\u9032\u3081\u308b\u305f\u308137\u2103\u306715\u5206\u9593\u51e6\u7406\u3057\u3001\u7d9a\u3051\u306695\u2103\u30675\u5206\u9593\u51e6\u7406\u3057\u3066\u5236\u9650\u9175\u7d20\u3092\u5931\u6d3b\u3055\u305b\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306e\u6e96\u5099\u4e2d\u306a\u3069\u306b\u53cd\u5fdc\u304c\u9032\u307e\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u305f\u3081\u3067\u3059\u3002<\/p>\n<table style=\"border-collapse: collapse;border-color: silver\" border=\"2\">\n<caption><b>\u88682\u3000\u5236\u9650\u9175\u7d20\u306e\u53cd\u5fdc\u6db2\uff0820 \u00b5L\uff09\u306e\u6df7\u5408\u6761\u4ef6<\/b><\/caption>\n<tbody>\n<tr bgcolor=\"white\">\n<td style=\"text-align: center\" width=\"20\"><b>\u6761\u4ef6<\/b><\/td>\n<td style=\"text-align: center\" width=\"60\"><b>\u9175\u7d20<\/b><\/td>\n<td style=\"text-align: center\" width=\"60\"><b>\u30d4\u30da\u30c3\u30c8\u5bb9\u91cf<\/b><\/td>\n<td style=\"text-align: center\" width=\"60\"><b>\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u56de\u6570<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"20\">1<\/td>\n<td style=\"text-align: center\" width=\"60\">Nuclease-Free Water<\/td>\n<td style=\"text-align: center\" width=\"60\">15 \u00b5L<\/td>\n<td style=\"text-align: center\" width=\"60\">5\u56de<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"20\">2<\/td>\n<td style=\"text-align: center\" width=\"60\">Hind III<\/td>\n<td style=\"text-align: center\" width=\"60\">15 \u00b5L<\/td>\n<td style=\"text-align: center\" width=\"60\">5\u56de<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"20\">3<\/td>\n<td style=\"text-align: center\" width=\"60\">Hind III<\/td>\n<td style=\"text-align: center\" width=\"60\">1 \u00b5L<\/td>\n<td style=\"text-align: center\" width=\"60\">5\u56de<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"20\">4<\/td>\n<td style=\"text-align: center\" width=\"60\">Hind III<\/td>\n<td style=\"text-align: center\" width=\"60\">NA<\/td>\n<td style=\"text-align: center\" width=\"60\">0\u56de<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u5236\u9650\u9175\u7d20\u3067DNA\u304c\u5207\u65ad\u3055\u308c\u305f\u304b\u3069\u3046\u304b\u306e\u78ba\u8a8d\u306f\u3001\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u3067DNA\u306e\u30d0\u30f3\u30c9\u3092\u53ef\u8996\u5316\u3057\u3066\u65ad\u7247\u306e\u30b5\u30a4\u30ba\u304b\u3089\u5224\u65ad\u3057\u307e\u3057\u305f\u3002\u96fb\u6c17\u6cf3\u52d5\u306b\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/dna-rna-purification-analysis\/nucleic-acid-gel-electrophoresis\/e-gel-electrophoresis-system\/e-gel-routine-na-electrophoresis.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u2122 E-Gel Power Snap\u96fb\u6c17\u6cf3\u52d5\u30b7\u30b9\u30c6\u30e0<\/a>\u3068Invitrogen\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/dna-rna-purification-analysis\/nucleic-acid-gel-electrophoresis\/e-gel-electrophoresis-system\/e-gel-pre-cast-agarose-gels\/e-gel-ex-precast-agarose-gels.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">E-Gel\u2122 EX \u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb<\/a>\uff081%\uff09\u3092\u4f7f\u7528\u3057\u3001\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\u306b\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10787018?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">Invitrogen\u21221 Kb Plus DNA Ladder<\/a> \u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002<\/p>\n<h2>\u7d50\u679c<\/h2>\n<p>\u305d\u308c\u3067\u306f\u7d50\u679c\u3092\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002<br \/>\n\u30ec\u30fc\u30f31\u306f\u5236\u9650\u9175\u7d20Hind III\u3092\u52a0\u3048\u306a\u3044\u30cd\u30ac\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306e\u305f\u3081\u3001PCR\u7523\u7269\u304c\u5207\u65ad\u3055\u308c\u3066\u304a\u3089\u305a1042 bp\u306eDNA\u306e\u30d0\u30f3\u30c9\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002\u30ec\u30fc\u30f32\u306fHind III\u3092\u52a0\u3048\u3066\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u305f\u6761\u4ef6\u3067\u3059\u306e\u3067\u3001\u4e88\u60f3\u3055\u308c\u305f\u901a\u308a651 bp\u3068397 bp\u7a0b\u5ea6\u306eDNA\u65ad\u7247\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002\u30ec\u30fc\u30f33\u306f1 \u00b5L\u5bb9\u91cf\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3001\u30ec\u30fc\u30f34\u306f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u5168\u304f\u3057\u306a\u3044\u6761\u4ef6\u3067\u3059\u3002\u3069\u3061\u3089\u306e\u30ec\u30fc\u30f3\u3082\u540c\u69d8\u306e\u7d50\u679c\u3067\u3001\u4e0a\u304b\u30891042 bp\u3001651 bp\u3001397 bp\u306e3\u672c\u306e\u30d0\u30f3\u30c9\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002\u610f\u5916\u306a\u3053\u3068\u306b\u3001\u5168\u304f\u53cd\u5fdc\u6db2\u3092\u6df7\u305c\u3066\u3044\u306a\u304f\u3066\u3082\u3001Hind III\u306b\u3088\u3063\u3066\u3042\u308b\u7a0b\u5ea6\u306f651 bp\u3068397 bp\u306eDNA\u65ad\u7247\u3078\u3068\u5207\u65ad\u3067\u304d\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001Hind III\u3092\u52a0\u3048\u3066\u9175\u7d20\u304c\u6c88\u3093\u3067\u3044\u304f\u969b\u306bDNA\u3092\u542b\u3080\u53cd\u5fdc\u6db2\u3068\u591a\u5c11\u306f\u6df7\u3056\u3063\u305f\u308a\u3001\u6c88\u3093\u3060\u9175\u7d20\u3068\u63a5\u3059\u308b\u3068\u3053\u308d\u3067DNA\u3068\u53cd\u5fdc\u3057\u305f\u3053\u3068\u306a\u3069\u304c\u8003\u3048\u3089\u308c\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u4e00\u756a\u4e0a\u306e1042 bp\u306e\u30d0\u30f3\u30c9\u306f\u5143\u306ePCR\u7523\u7269\u3067\u3059\u306e\u3067\u3001\u304b\u306a\u308a\u5207\u308c\u6b8b\u3063\u3066\u3044\u308b\u3068\u3044\u3046\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u3084\u306f\u308a\u3001\u5236\u9650\u9175\u7d20\u51e6\u7406\u306e\u5834\u5408\u3067\u3082\u3001\u8a66\u85ac\u306e\u7dcf\u6db2\u91cf\u306e\u5c11\u306a\u304f\u3068\u3082\u534a\u91cf\u4ee5\u4e0a\u306e\u5bb9\u91cf\u3067\u3086\u3063\u304f\u308a\u4e01\u5be7\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3042\u308b\u3053\u3068\u3092\u304a\u793a\u3057\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_15912\" style=\"width: 460px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15912\" class=\"wp-image-15912\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_02-1024x938.jpg\" alt=\"\u56f32. \u5236\u9650\u9175\u7d20\u51e6\u7406\u5f8c\u306e\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306e\u7d50\u679c M. \u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc(1 kb Plus DNA Ladder) 1. Hind III\u306a\u3057\uff1a15 \u03bcL\u5bb9\u91cf\u3067\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0 2. Hind III\u3042\u308a\uff1a15 \u03bcL\u5bb9\u91cf\u3067\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0 3. Hind III\u3042\u308a\uff1a1 \u03bcL\u5bb9\u91cf\u3067\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0 4. Hind III\u3042\u308a\uff1a\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u306a\u3044 \u203b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u56de\u6570\u306f\u3044\u305a\u308c\u30825\u56de\" width=\"450\" height=\"412\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_02-1024x938.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_02-300x275.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_02-768x704.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/basic-workshop-gsd-ts-3_02.jpg 1063w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><p id=\"caption-attachment-15912\" class=\"wp-caption-text\">\u56f32. \u5236\u9650\u9175\u7d20\u51e6\u7406\u5f8c\u306e\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u306e\u7d50\u679c<br \/>M. \u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc(1 kb Plus DNA Ladder)<br \/>1. Hind III\u306a\u3057\uff1a15 \u03bcL\u5bb9\u91cf\u3067\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0 5\u56de<br \/>2. Hind III\u3042\u308a\uff1a15 \u03bcL\u5bb9\u91cf\u3067\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0 5\u56de<br \/>3. Hind III\u3042\u308a\uff1a1 \u03bcL\u5bb9\u91cf\u3067\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0 5\u56de<br \/>4. Hind III\u3042\u308a\uff1a\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u306a\u3044<\/p><\/div>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u3001\u5b9f\u969b\u306b\u5236\u9650\u9175\u7d20\u51e6\u7406\u3092\u5b9f\u65bd\u3057\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306e\u6df7\u5408\u304c\u4e0d\u5341\u5206\u3060\u3068\u5b9f\u9a13\u7d50\u679c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u304c\u3042\u308b\u306e\u304b\u3092\u3084\u3063\u3066\u307f\u307e\u3057\u305f\u3002\u8a66\u85ac\u306a\u3069\u3092\u6df7\u5408\u3059\u308b\u969b\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u5bb9\u91cf\u306f\u3001\u5c11\u306a\u304f\u3068\u3082\u7dcf\u6db2\u91cf\u306e\u534a\u91cf\u4ee5\u4e0a\u3068\u3044\u3046\u3053\u3068\u3092\u610f\u8b58\u3057\u3066\u5b9f\u9a13\u306b\u53d6\u308a\u7d44\u3093\u3067\u3044\u305f\u3060\u304f\u3068\u3001\u3088\u308a\u6b63\u78ba\u306a\u5b9f\u9a13\u30c7\u30fc\u30bf\u3092\u5f97\u3066\u3044\u305f\u3060\u3051\u308b\u306e\u3067\u306f\u306a\u3044\u304b\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<p><b>\u5f53\u793e\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c4\u30fc\u30eb\u306e\u9078\u629e\u3084\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u9069\u3057\u305f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c6\u30af\u30cb\u30c3\u30af\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u308b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/b><\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/glp-guide-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p><b>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9 \u304a\u554f\u3044\u5408\u308f\u305b\u30fb\u30ab\u30bf\u30ed\u30b0<\/b><\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-inquiry.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u95a2\u9023\u3059\u308b\u8a18\u4e8b<br \/>\n\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u8a66\u85ac\u3092\u3057\u3063\u304b\u308a\u6df7\u5408\u3059\u308b\u305f\u3063\u305f1\u3064\u306e\u30b3\u30c4\u3092\u52d5\u753b\u306b\u3057\u3066\u307f\u305f<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tr-workshop-gsd-ts-1\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tr-workshop-gsd-ts-1\/<\/a><\/p>\n<p>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51cd\u7d50\u30b5\u30f3\u30d7\u30eb\u3001\u6eb6\u89e3\u5f8c\u306b\u3057\u3063\u304b\u308a\u6df7\u305c\u306a\u3044\u3068\u3053\u3093\u306a\u306b\u5dee\u304c\u51fa\u308b\uff01<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/frozen_sample_workshop_ts_1\/?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_og_s00_basic_workshop_gsd_ts_3_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/frozen_sample_workshop_ts_1\/<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30d0\u30a4\u30aa\u5b9f\u9a13\u3067\u306f\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6db2\u4f53\u8a66\u85ac\u3092\u6df7\u5408\u3059\u308b\u3053\u3068\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u53cd\u5fdc\u3092\u9032\u3081\u307e\u3059\u3002\u6df7\u5408\u65b9\u6cd5\u306b\u306f\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u4ed6\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3084\u30bf\u30c3\u30d4\u30f3\u30b0\u3001\u8ee2\u5012\u6df7\u548c\u306a\u3069\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u9175\u7d20\u6d3b\u6027\u3078\u306e\u5f71\u97ff\u304c\u6c17\u306b\u306a\u308b\u5834\u9762\u3067\u306f\u3001\u6bd4\u8f03\u7684<\/p>\n","protected":false},"author":975,"featured_media":14790,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[9,41,28],"division":[],"class_list":["post-15898","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-pcr","tag-pipetting","tag-experiment","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089\" \/>\n<meta property=\"og:description\" content=\"\u30d0\u30a4\u30aa\u5b9f\u9a13\u3067\u306f\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6db2\u4f53\u8a66\u85ac\u3092\u6df7\u5408\u3059\u308b\u3053\u3068\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u53cd\u5fdc\u3092\u9032\u3081\u307e\u3059\u3002\u6df7\u5408\u65b9\u6cd5\u306b\u306f\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u4ed6\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3084\u30bf\u30c3\u30d4\u30f3\u30b0\u3001\u8ee2\u5012\u6df7\u548c\u306a\u3069\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u9175\u7d20\u6d3b\u6027\u3078\u306e\u5f71\u97ff\u304c\u6c17\u306b\u306a\u308b\u5834\u9762\u3067\u306f\u3001\u6bd4\u8f03\u7684\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-12-19T01:19:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T07:53:45+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"612\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089\",\"datePublished\":\"2023-12-19T01:19:24+00:00\",\"dateModified\":\"2025-07-02T07:53:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/\"},\"wordCount\":133,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/shutterstock_2322725903.jpg\",\"keywords\":[\"PCR\",\"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099\",\"\u3084\u3063\u3066\u307f\u305f\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/shutterstock_2322725903.jpg\",\"datePublished\":\"2023-12-19T01:19:24+00:00\",\"dateModified\":\"2025-07-02T07:53:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/shutterstock_2322725903.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/07\\\/shutterstock_2322725903.jpg\",\"width\":1000,\"height\":612},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/basic-workshop-gsd-ts-3\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089","og_description":"\u30d0\u30a4\u30aa\u5b9f\u9a13\u3067\u306f\u3001\u30de\u30a4\u30af\u30ed\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6db2\u4f53\u8a66\u85ac\u3092\u6df7\u5408\u3059\u308b\u3053\u3068\u3067\u3001\u3055\u307e\u3056\u307e\u306a\u53cd\u5fdc\u3092\u9032\u3081\u307e\u3059\u3002\u6df7\u5408\u65b9\u6cd5\u306b\u306f\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u4ed6\u3001\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u3084\u30bf\u30c3\u30d4\u30f3\u30b0\u3001\u8ee2\u5012\u6df7\u548c\u306a\u3069\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u9175\u7d20\u6d3b\u6027\u3078\u306e\u5f71\u97ff\u304c\u6c17\u306b\u306a\u308b\u5834\u9762\u3067\u306f\u3001\u6bd4\u8f03\u7684","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-12-19T01:19:24+00:00","article_modified_time":"2025-07-02T07:53:45+00:00","og_image":[{"width":1000,"height":612,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089","datePublished":"2023-12-19T01:19:24+00:00","dateModified":"2025-07-02T07:53:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/"},"wordCount":133,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg","keywords":["PCR","\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099","\u3084\u3063\u3066\u307f\u305f"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg","datePublished":"2023-12-19T01:19:24+00:00","dateModified":"2025-07-02T07:53:45+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg","width":1000,"height":612},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/basic-workshop-gsd-ts-3\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5236\u9650\u9175\u7d20\u3067DNA\u3092\u5207\u65ad\u3059\u308b\u6642\u306b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u3057\u3063\u304b\u308a\u6df7\u5408\u3057\u306a\u304b\u3063\u305f\u3089"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":9,"label":"PCR"},{"value":41,"label":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"},{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg",760,465,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":539,"filter":"raw","meta":[],"cat_ID":156,"category_count":539,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":9,"name":"PCR","slug":"pcr","term_group":0,"term_taxonomy_id":9,"taxonomy":"post_tag","description":"","parent":0,"count":29,"filter":"raw","meta":[]},{"term_id":41,"name":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099","slug":"pipetting","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/07\/shutterstock_2322725903.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15898","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=15898"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15898\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/14790"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=15898"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=15898"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=15898"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=15898"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}