{"id":15925,"date":"2023-12-22T10:14:41","date_gmt":"2023-12-22T01:14:41","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=15925"},"modified":"2025-02-07T15:58:16","modified_gmt":"2025-02-07T06:58:16","slug":"foreign_material_raman_msd_sales-1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/","title":{"rendered":"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a"},"content":{"rendered":"<p>\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u306f\u5f93\u6765\u306e\u30e9\u30de\u30f3\u30de\u30c3\u30d4\u30f3\u30b0\u6e2c\u5b9a\u306b\u6bd4\u3079\u5e83\u7bc4\u56f2\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u8fc5\u901f\u306b\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u6210\u5206\u306e\u5206\u5e03\u3092\u89b3\u6e2c\u3059\u308b\u306e\u306b\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u3001\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u6a39\u8102\u6750\u6599\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a\u3092\u884c\u3063\u305f\u4f8b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30b5\u30f3\u30d7\u30eb<\/h2>\n<p>\u677f\u72b6\u306e\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\uff08\u539a\u3055\u7d041.4 mm\uff09\u3092\u4e00\u90e8\u5207\u308a\u53d6\u308a\u3001\u6298\u308a\u66f2\u3052\u307e\u3057\u305f\u3002\u3053\u306e\u64cd\u4f5c\u306b\u3088\u308a\u3001\u5c48\u66f2\u90e8\u306b\u5fdc\u529b\u304c\u304b\u304b\u308a\u3001\u4e00\u90e8\u767d\u6fc1\u3059\u308b\u69d8\u5b50\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u5243\u5200\u306b\u3088\u308a\u65ad\u9762\u3092\u5207\u308a\u51fa\u3057\u3001\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_15927\" style=\"width: 692px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15927\" class=\"size-full wp-image-15927\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_1.png\" alt=\"\u56f31\uff1a\u677f\u72b6\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u30b5\u30f3\u30d7\u30eb\u306e\u6982\u7565\u56f3\u3068\u5207\u308a\u51fa\u3057\u65ad\u9762\u306e\u53ef\u8996\u753b\u50cf\" width=\"682\" height=\"312\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_1.png 682w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_1-300x137.png 300w\" sizes=\"auto, (max-width: 682px) 100vw, 682px\" \/><p id=\"caption-attachment-15927\" class=\"wp-caption-text\">\u56f31\uff1a\u677f\u72b6\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u30b5\u30f3\u30d7\u30eb\u306e\u6982\u7565\u56f3\u3068\u5207\u308a\u51fa\u3057\u65ad\u9762\u306e\u53ef\u8996\u753b\u50cf<\/p><\/div>\n<h2>\u6e2c\u5b9a<\/h2>\n<p>\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u304a\u3088\u3073\u89e3\u6790\u306b\u306f\u3001\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u793e\u88fd\u306eThermo Scientific\u2122 DXR\u2122 3xi\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u9855\u5fae\u30e9\u30de\u30f3\u3068\u4ed8\u5c5e\u306eThermo Scientific\u2122 OMNICxi\u2122\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u7528\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7528\u3044\u307e\u3057\u305f\u3002<\/p>\n<p>DXR3xi\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u9855\u5fae\u30e9\u30de\u30f3\u306f\u5e83\u7bc4\u56f2\u306e\u9ad8\u901f\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u30680.5 \u03bcm\u4ee5\u4e0b\u306e\u5fae\u5c0f\u30a8\u30ea\u30a2\u306e\u9ad8\u7a7a\u9593\u5206\u89e3\u80fd\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u4e21\u7acb\u3057\u3001\u3055\u3089\u306b\u30e6\u30cb\u30fc\u30af\u306a\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u69cb\u306b\u3088\u308a\u3001\u5e38\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u72b6\u614b\u3067\u3054\u4f7f\u7528\u3044\u305f\u3060\u3051\u308b\u88fd\u54c1\u3067\u3059\u3002<\/p>\n<p>\u672c\u5b9f\u9a13\u306b\u7528\u3044\u305f\u3001\u4e3b\u306a\u6e2c\u5b9a\u6761\u4ef6\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n<p><b>\uff1c\u6e2c\u5b9a\u6761\u4ef6\uff1e<\/b><br \/>\n\u30ec\u30fc\u30b6\u30fc\u6ce2\u9577\uff1a 532 nm<br \/>\n\u30b9\u30da\u30af\u30c8\u30eb\u6570\uff1a 11543<br \/>\n\u6e2c\u5b9a\u30a8\u30ea\u30a2\u30b5\u30a4\u30ba\uff1a \u7d043.6\u00d72.9 mm<br \/>\n\u6e2c\u5b9a\u6642\u9593\uff1a \u7d0425\u5206<\/p>\n<div id=\"attachment_15928\" style=\"width: 521px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15928\" class=\"size-full wp-image-15928\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png\" alt=\"\u56f32\uff1aDXR3xi\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u9855\u5fae\u30e9\u30de\u30f3\" width=\"511\" height=\"367\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png 511w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2-300x215.png 300w\" sizes=\"auto, (max-width: 511px) 100vw, 511px\" \/><p id=\"caption-attachment-15928\" class=\"wp-caption-text\">\u56f32\uff1aDXR3xi\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u9855\u5fae\u30e9\u30de\u30f3<\/p><\/div>\n<h2>\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u7d50\u679c<\/h2>\n<p>\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5c48\u66f2\u90e8\u8fd1\u508d\u30672960 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306e\u30d4\u30fc\u30af\u304c\u30b7\u30d5\u30c8\u3059\u308b\u69d8\u5b50\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u306e\u30d4\u30fc\u30af\u30b7\u30d5\u30c8\u3092\u7528\u3044\u89e3\u6790\u3057\u305f\u3068\u3053\u308d\u3001\u56f33\u306e\u30a4\u30e1\u30fc\u30b8\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u5c48\u66f2\u90e8\u8fd1\u508d\u306b\u5fdc\u529b\u304c\u751f\u3058\u3066\u3044\u308b\u69d8\u5b50\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<div id=\"attachment_15929\" style=\"width: 694px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15929\" class=\"size-large wp-image-15929\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_3-1024x499.png\" alt=\"\u56f33\uff1a2960 cm-1\u4ed8\u8fd1\u306e\u30d4\u30fc\u30af\u30b7\u30d5\u30c8\u306b\u3088\u308a\u89e3\u6790\u3057\u305f\u30a4\u30e1\u30fc\u30b8\uff08\u5de6\uff09\u3068\u3001\u5c48\u66f2\u90e8\u304a\u3088\u3073\u5c48\u66f2\u90e8\u3088\u308a\u96e2\u308c\u305f\u5834\u6240\u306e\u30b9\u30da\u30af\u30c8\u30eb\uff08\u53f3\uff09\" width=\"684\" height=\"333\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_3-1024x499.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_3-300x146.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_3-768x374.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_3.png 1111w\" sizes=\"auto, (max-width: 684px) 100vw, 684px\" \/><p id=\"caption-attachment-15929\" class=\"wp-caption-text\">\u56f33\uff1a2960 cm<sup>-1<\/sup>\u4ed8\u8fd1\u306e\u30d4\u30fc\u30af\u30b7\u30d5\u30c8\u306b\u3088\u308a\u89e3\u6790\u3057\u305f\u30a4\u30e1\u30fc\u30b8\uff08\u5de6\uff09\u3068\u3001\u5c48\u66f2\u90e8\u304a\u3088\u3073\u5c48\u66f2\u90e8\u3088\u308a\u96e2\u308c\u305f\u5834\u6240\u306e\u30b9\u30da\u30af\u30c8\u30eb\uff08\u53f3\uff09<\/p><\/div>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u3092\u884c\u3046\u3053\u3068\u306b\u3088\u308a\u3001\u9ad8\u5206\u5b50\u6750\u6599\u3084\u6210\u5f62\u54c1\u306a\u3069\u306e\u5fdc\u529b\u5206\u5e03\u3092\u30a4\u30e1\u30fc\u30b8\u50cf\u3068\u3057\u3066\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u6e2c\u5b9a\u306b\u3088\u308a\u30d4\u30f3\u30dd\u30a4\u30f3\u30c8\u306e\u30b9\u30da\u30af\u30c8\u30eb\u6e2c\u5b9a\u3067\u306f\u5224\u5225\u304c\u56f0\u96e3\u306a\u5fdc\u529b\u5206\u5e03\u8a55\u4fa1\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<p><b>\u95a2\u9023\u60c5\u5831<\/b><br \/>\n\u95a2\u9023\u88fd\u54c1Web\u30da\u30fc\u30b8\u2192 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/raman-microscopy\/instruments\/dxr3xi-raman-imaging-microscope.html?CID=foreign_material_raman_msd_sales_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">DXR3xi \u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u9855\u5fae\u30e9\u30de\u30f3<\/a><\/p>\n<p>\u30c7\u30e2\u4f7f\u7528\u3084\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3054\u5e0c\u671b\u306e\u65b9\u306f\u4e0b\u8a18\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/ftir-inquiry-form.html?CID=foreign_material_raman_msd_sales_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u306f\u5f93\u6765\u306e\u30e9\u30de\u30f3\u30de\u30c3\u30d4\u30f3\u30b0\u6e2c\u5b9a\u306b\u6bd4\u3079\u5e83\u7bc4\u56f2\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u8fc5\u901f\u306b\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u6210\u5206\u306e\u5206\u5e03\u3092\u89b3\u6e2c\u3059\u308b\u306e\u306b\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u3001\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u6a39\u8102\u6750\u6599\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a\u3092\u884c\u3063<\/p>\n","protected":false},"author":975,"featured_media":15928,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[222],"division":[],"class_list":{"0":"post-15925","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-analysis","8":"tag-raman","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a\" \/>\n<meta property=\"og:description\" content=\"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u306f\u5f93\u6765\u306e\u30e9\u30de\u30f3\u30de\u30c3\u30d4\u30f3\u30b0\u6e2c\u5b9a\u306b\u6bd4\u3079\u5e83\u7bc4\u56f2\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u8fc5\u901f\u306b\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u6210\u5206\u306e\u5206\u5e03\u3092\u89b3\u6e2c\u3059\u308b\u306e\u306b\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u3001\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u6a39\u8102\u6750\u6599\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a\u3092\u884c\u3063\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-12-22T01:14:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-07T06:58:16+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"511\" \/>\n\t<meta property=\"og:image:height\" content=\"367\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"4\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a\",\"datePublished\":\"2023-12-22T01:14:41+00:00\",\"dateModified\":\"2025-02-07T06:58:16+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/\"},\"wordCount\":42,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/foreign_material_raman_msd_sales_1_2.png\",\"keywords\":[\"\u30e9\u30de\u30f3\u5206\u5149\u6cd5\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/\",\"name\":\"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/foreign_material_raman_msd_sales_1_2.png\",\"datePublished\":\"2023-12-22T01:14:41+00:00\",\"dateModified\":\"2025-02-07T06:58:16+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/foreign_material_raman_msd_sales_1_2.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/foreign_material_raman_msd_sales_1_2.png\",\"width\":511,\"height\":367,\"caption\":\"\u56f32\uff1aDXR3xi\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u9855\u5fae\u30e9\u30de\u30f3\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/foreign_material_raman_msd_sales-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a","og_description":"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6e2c\u5b9a\u306f\u5f93\u6765\u306e\u30e9\u30de\u30f3\u30de\u30c3\u30d4\u30f3\u30b0\u6e2c\u5b9a\u306b\u6bd4\u3079\u5e83\u7bc4\u56f2\u306e\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u8fc5\u901f\u306b\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u6210\u5206\u306e\u5206\u5e03\u3092\u89b3\u6e2c\u3059\u308b\u306e\u306b\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u3001\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u6a39\u8102\u6750\u6599\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a\u3092\u884c\u3063","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-12-22T01:14:41+00:00","article_modified_time":"2025-02-07T06:58:16+00:00","og_image":[{"width":511,"height":367,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"4\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a","datePublished":"2023-12-22T01:14:41+00:00","dateModified":"2025-02-07T06:58:16+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/"},"wordCount":42,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png","keywords":["\u30e9\u30de\u30f3\u5206\u5149\u6cd5"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/","name":"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png","datePublished":"2023-12-22T01:14:41+00:00","dateModified":"2025-02-07T06:58:16+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png","width":511,"height":367,"caption":"\u56f32\uff1aDXR3xi\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u9855\u5fae\u30e9\u30de\u30f3"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/foreign_material_raman_msd_sales-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30e9\u30de\u30f3\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u7528\u3044\u305f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306e\u5fdc\u529b\u5206\u5e03\u6e2c\u5b9a"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":222,"label":"\u30e9\u30de\u30f3\u5206\u5149\u6cd5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png",511,367,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":105,"filter":"raw","meta":[],"cat_ID":157,"category_count":105,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":222,"name":"\u30e9\u30de\u30f3\u5206\u5149\u6cd5","slug":"raman","term_group":0,"term_taxonomy_id":222,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/foreign_material_raman_msd_sales_1_2.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15925","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=15925"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15925\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/15928"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=15925"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=15925"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=15925"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=15925"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}