{"id":15949,"date":"2023-12-25T12:02:17","date_gmt":"2023-12-25T03:02:17","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=15949"},"modified":"2024-12-25T15:57:27","modified_gmt":"2024-12-25T06:57:27","slug":"cell-count-workshop-bid-ts-1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f"},"content":{"rendered":"<p>\u7d30\u80de\u57f9\u990a\u3092\u3055\u308c\u3066\u3044\u308b\u65b9\u306f\u3001\u7d30\u80de\u306e\u61f8\u6fc1\u6db2\u3092\u3046\u3063\u304b\u308a\u653e\u7f6e\u3057\u3066\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306b\u7d30\u80de\u304c\u6c88\u3093\u3067\u3057\u307e\u3046\u3053\u3068\u3092\u7d4c\u9a13\u3055\u308c\u3066\u3044\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u77ed\u6642\u9593\u3067\u3042\u3063\u3066\u3082\u591a\u5c11\u306f\u6c88\u6bbf\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u3001\u653e\u7f6e\u3057\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306f\u3057\u3063\u304b\u308a\u3068\u6df7\u5408\u3057\u3066\u7d30\u80de\u6fc3\u5ea6\u3092\u5747\u4e00\u306b\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<br \/>\n\u3067\u306f\u3001\u7d30\u80de\u306f\u3069\u308c\u304f\u3089\u3044\u653e\u7f6e\u3057\u305f\u3089\u3069\u308c\u304f\u3089\u3044\u6c88\u6bbf\u3059\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u3069\u306e\u304f\u3089\u3044\u306e\u653e\u7f6e\u6642\u9593\u307e\u3067\u3067\u3042\u308c\u3070\u3001\u3042\u3089\u305f\u3081\u3066\u6df7\u5408\u3059\u308b\u5fc5\u8981\u306f\u306a\u304f\u306a\u308b\u3067\u3057\u3087\u3046\u304b\uff1f\u6c17\u306b\u306a\u3063\u305f\u306e\u3067\u3084\u3063\u3066\u307f\u307e\u3057\u305f\uff01<\/p>\n<h2>\u5b9f\u9a131\uff1a\u6750\u6599\u3068\u65b9\u6cd5<\/h2>\n<ul>\n<li>\u7d30\u80de\u306f2\u7a2e\u985e\uff1aHeLa\uff08\u30d2\u30c8\u5b50\u5bae\u9838\u304c\u3093\u7d30\u80de\u682a\uff09\u3001Jurkat\uff08\u30d2\u30c8T\u7d30\u80de\u30ea\u30f3\u30d1\u816b\u7d30\u80de\u682a\uff09<\/li>\n<li>15 mL\u30c1\u30e5\u30fc\u30d6\u306b\u7d30\u80de\u61f8\u6fc1\u6db23 mL\u3092\u6e96\u5099<\/li>\n<li>\u6c34\u9762\u304b\u3089\u7d041 cm\uff08\u30c1\u30e5\u30fc\u30d6\u306e2 mL\u76ee\u76db\u308a\uff09\u5730\u70b9\u304b\u308910 \u03bcL\u3092\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u3067\u63a1\u53d6\uff08\u56f31\uff09<\/li>\n<li>\u5927\u6c17\u5727\u6761\u4ef6\u4e0b\u3067\u6642\u9593\u7d4c\u904e\u3054\u3068\u306b\u63a1\u53d6\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3092Invitrogen\u2122 Countess\u2122 3\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u3067\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u3002n=3\u3067\u5b9f\u65bd<\/li>\n<li>0\u5206\u30011\u5206\u30013\u5206\u30015\u5206\u300110\u5206\u300115\u5206\u300130\u5206\u300160\u5206\u306e8\u70b9\u3067\u5b9f\u65bd<br \/>\n\u203b8\u70b9\u76ee\u306b\u306f\u6db2\u91cf\u304c240 \u03bcL\u5c11\u306a\u304f\u306a\u308a\u6c34\u9762\u304b\u3089\u306e\u8ddd\u96e2\u304c\u5909\u308f\u3063\u3066\u304f\u308b\u304c\u8aa4\u5dee\u3068\u5224\u65ad<\/li>\n<\/ul>\n<div id=\"attachment_15954\" style=\"width: 210px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15954\" class=\"wp-image-15954\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-01-155x300.jpg\" alt=\"\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u306e\u69d8\u5b50\" width=\"200\" height=\"387\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-01-155x300.jpg 155w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-01.jpg 348w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><p id=\"caption-attachment-15954\" class=\"wp-caption-text\">\u56f31. \u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u306e\u69d8\u5b50<br \/>\u7d30\u80de\u61f8\u6fc1\u6db23 mL\u306e\u6c34\u9762\u304b\u3089\u7d041 cm\u306e\u5730\u70b9\u304b\u308910 \u00b5L\u3092\u53d6\u308a\u3001\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u3092\u5b9f\u65bd\uff08n=3\uff09\u3002<\/p><\/div>\n<div id=\"attachment_15950\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15950\" class=\"size-large wp-image-15950\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-02-1024x370.jpg\" alt=\"HeLa\u3068Jurkat\u306e\u9855\u5fae\u93e1\u50cf\" width=\"760\" height=\"275\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-02-1024x370.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-02-300x108.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-02-768x278.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-02.jpg 1065w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-15950\" class=\"wp-caption-text\">\u56f32. HeLa\u3068Jurkat\u306e\u9855\u5fae\u93e1\u50cf<br \/>HeLa\u306f\u63a5\u7740\u7d30\u80de\u3060\u304c\u61f8\u6fc1\u72b6\u614b\uff08\u6d6e\u904a\u72b6\u614b\uff09\u3067\u3082\u64ae\u5f71\u3002<\/p><\/div>\n<div id=\"attachment_15953\" style=\"width: 210px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/cell-analysis-instruments\/automated-cell-counters.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_count_workshop_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15953\" class=\"wp-image-15953 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/Countess-3-Automated-Cell-Counter.jpg\" alt=\"Countess 3\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\" width=\"200\" height=\"200\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/Countess-3-Automated-Cell-Counter.jpg 200w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/Countess-3-Automated-Cell-Counter-150x150.jpg 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/Countess-3-Automated-Cell-Counter-80x80.jpg 80w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/a><p id=\"caption-attachment-15953\" class=\"wp-caption-text\">Countess 3\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc<\/p><\/div>\n<h2>\u5b9f\u9a131\uff1a\u7d50\u679c<\/h2>\n<p>\u7d30\u80de\u304c2\u7a2e\u985e\u3001n=3\u30678\u70b9\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u30ab\u30a6\u30f3\u30c8\u3057\u305f\u7d50\u679c\u3067\u3059\u3002\u5408\u8a08\u306748\u30b5\u30f3\u30d7\u30eb\u306e\u30ab\u30a6\u30f3\u30c8\u3092\u884c\u3044\u307e\u3057\u305f\u304c\u3001\u8840\u7403\u8a08\u7b97\u76e4\u3067\u306e\u624b\u52d5\u8a08\u6570\u3067\u306a\u304f\u3066\u672c\u5f53\u306b\u826f\u304b\u3063\u305f\u3068\u611f\u3058\u307e\u3057\u305f\u3002\u30ab\u30a6\u30f3\u30c8\u306b\u306f\u5f53\u793e\u306eCountess 3\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u304c\u3001\u305d\u306e\u7c21\u4fbf\u3055\u3092\u3042\u3089\u305f\u3081\u3066\u5b9f\u611f\u3057\u307e\u3057\u305f\u3002\u8840\u7403\u8a08\u7b97\u76e4\u3057\u304b\u4f7f\u3048\u306a\u3044\u74b0\u5883\u3060\u3063\u305f\u308948\u30b5\u30f3\u30d7\u30eb\u3082\u30ab\u30a6\u30f3\u30c8\u3067\u304d\u305a\u3001\u9014\u4e2d\u3067\u5fc3\u304c\u6298\u308c\u3066\u3044\u305f\u3068\u601d\u3044\u307e\u3059\u3002<br \/>\n\u3055\u3066\u3001\u7d50\u679c\u3067\u3059\u3002HeLa\u3067\u306f10\u5206\u304f\u3089\u3044\u307e\u3067\u3042\u307e\u308a\u5909\u5316\u304c\u306a\u304f\u300115\u5206\u4ee5\u964d\u306f\u7d30\u80de\u6570\u304c\u6e1b\u3063\u3066\u3044\u304d\u307e\u3057\u305f\uff08\u56f33\uff09\u3002Jurkat\u3067\u306f15\u5206\u307e\u3067\u306f\u5909\u5316\u304c\u306a\u304f\u300130\u5206\u4ee5\u964d\u3067\u7d30\u80de\u6570\u304c\u6e1b\u308a\u307e\u3057\u305f\uff08\u56f33\uff09<\/p>\n<div id=\"attachment_15951\" style=\"width: 770px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15951\" class=\"wp-image-15951 size-large\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-03-e1703472210577-1024x290.jpg\" alt=\"HeLa\u3068Jurkat\u306e\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u7d50\u679c\" width=\"760\" height=\"215\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-03-e1703472210577-1024x290.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-03-e1703472210577-300x85.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-03-e1703472210577-768x217.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-03-e1703472210577.jpg 1305w\" sizes=\"auto, (max-width: 760px) 100vw, 760px\" \/><p id=\"caption-attachment-15951\" class=\"wp-caption-text\">\u56f33. HeLa\u3068Jurkat\u306e\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u7d50\u679c<br \/>HeLa\u306f15\u5206\u3001Jurkat\u306f30\u5206\u4ee5\u964d\u3067\u9855\u8457\u306a\u7d30\u80de\u6fc3\u5ea6\u306e\u4f4e\u4e0b\u304c\u307f\u3089\u308c\u305f\u3002<\/p><\/div>\n<p>HeLa\u306fJurkat\u306b\u6bd4\u3079\u308b\u3068\u5927\u578b\u306e\u305f\u3081\u3001\u6c88\u964d\u901f\u5ea6\u3082\u901f\u304b\u3063\u305f\u3082\u306e\u3068\u601d\u308f\u308c\u307e\u3059\u3002HeLa\u306f10\uff5e15\u5206\u30671 cm\u5730\u70b9\u3067\u5f71\u97ff\u304c\u51fa\u305f\u305f\u3081\u300110\uff5e15 min\/cm\u3001Jurkat\u306f15\uff5e30 min\/cm\u3068\u60f3\u5b9a\u3055\u308c\u308b\u3053\u3068\u304b\u3089\u3001\u305d\u308c\u305e\u308c\u306e\u6c88\u964d\u901f\u5ea6\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u63a8\u6e2c\u3055\u308c\u307e\u3059\u3002<br \/>\nHeLa\uff1a1\u5206\u3042\u305f\u308a 0.7\uff5e1 mm<br \/>\nJurkat\uff1a1\u5206\u3042\u305f\u308a 0.3\uff5e0.7 mm<br \/>\n\u4eee\u306b10\u5206\u653e\u7f6e\u3057\u305f\u3089\u3001\u6570mm\u304b\u30891 cm\u304f\u3089\u3044\u6c88\u3080\u3068\u3044\u3046\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002\u9006\u306b\u3044\u3048\u3070\u3001\u653e\u7f6e10\u5206\u7a0b\u5ea6\u3067\u3042\u308c\u3070\u3001\u6c34\u9762\u4e0b1 cm\u4ee5\u4e0b\u304b\u3089\u63a1\u53d6\u3059\u308c\u3070\u7d30\u80de\u6fc3\u5ea6\u306b\u306f\u6975\u7aef\u306a\u5f71\u97ff\u306f\u306a\u3044\u3088\u3046\u3067\u3057\u305f\u3002<\/p>\n<p>\u3053\u306e\u5b9f\u9a13\u3067\u306f\u4e0a\u90e8\u304b\u3089\u7d041 cm\u306e\u5730\u70b9\u3067\u6e2c\u5b9a\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u7d30\u80de\u306f\u91cd\u529b\u306b\u3088\u308a\u4e0b\u65b9\u5411\u306b\u3057\u304b\u79fb\u52d5\u3057\u306a\u3044\u305f\u3081\u3001\u6c88\u964d\u306b\u3088\u308b\u5f71\u97ff\u306f\u4e0a\u90e8\uff08\u6c34\u9762\uff09\u304a\u3088\u3073\u5e95\u90e8\u304b\u3089\u51fa\u59cb\u3081\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u6b21\u306e\u5b9f\u9a13\u3092\u3057\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n<h2>\u5b9f\u9a132\uff1a\u6750\u6599\u3068\u65b9\u6cd5<\/h2>\n<ul>\n<li>\u7d30\u80de\u306fJurkat\u3092\u4f7f\u7528\uff08\u5b9f\u9a131\u306e\u6b8b\u308a\uff09<\/li>\n<li>\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u306e\u4f4d\u7f6e\u306f\u2460\u6c34\u9762\u3001\u2461\u6c34\u9762\u304b\u3089\u7d041 cm\uff08\u5b9f\u9a131\u306e\u30c7\u30fc\u30bf\u3092\u6d41\u7528\uff09\u3001\u2462\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306e3\u30ab\u6240<\/li>\n<li>\u305d\u306e\u4ed6\u306e\u6761\u4ef6\u306f\u5b9f\u9a131\u3068\u540c\u3058<\/li>\n<\/ul>\n<h2>\u5b9f\u9a132\uff1a\u7d50\u679c<\/h2>\n<p>\u8ffd\u52a0\u306748\u30b5\u30f3\u30d7\u30eb\uff08\u2460\u6c34\u976224\u30b5\u30f3\u30d7\u30eb\u3001\u2462\u30c1\u30e5\u30fc\u30d6\u306e\u5e9524\u30b5\u30f3\u30d7\u30eb\uff09\u3092\u6e2c\u5b9a\u3057\u307e\u3057\u305f\u3002\u672c\u5f53\u306bCountess 3\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u304c\u3042\u3063\u3066\u826f\u304b\u3063\u305f\u3067\u3059\u3002<\/p>\n<div id=\"attachment_15952\" style=\"width: 991px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-15952\" class=\"size-full wp-image-15952\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-04.jpg\" alt=\"\u2460\u6c34\u9762\u3001\u2461\u6c34\u9762\u304b\u3089\u7d041 cm\u3001\u2462\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306e\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u7d50\u679c\" width=\"981\" height=\"875\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-04.jpg 981w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-04-300x268.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/cell-count-workshop-bid-ts-1-04-768x685.jpg 768w\" sizes=\"auto, (max-width: 981px) 100vw, 981px\" \/><p id=\"caption-attachment-15952\" class=\"wp-caption-text\">\u56f34. \u2460\u6c34\u9762\u3001\u2461\u6c34\u9762\u304b\u3089\u7d041 cm\u3001\u2462\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306e\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u7d50\u679c<br \/>\u6c34\u9762\u306f\u958b\u59cb1\u5206\u304b\u3089\u7d30\u80de\u6fc3\u5ea6\u304c\u4f4e\u4e0b\u3057\u3001\u5927\u304d\u306a\u5f71\u97ff\u304c\u3042\u3063\u305f\u3002\u2462\u306e\u307f\u7e26\u8ef8\u306e\u30b9\u30b1\u30fc\u30eb\u304c\u7570\u306a\u308b\u70b9\u306b\u6ce8\u610f\u3002\u2461\u306f\u5b9f\u9a131\uff08\u56f33\uff09\u3088\u308a\u6d41\u7528\u3002<\/p><\/div>\n<p>\u3055\u3066\u3001\u7d50\u679c\u3067\u3059\u3002\u2460\u6c34\u9762\u306f\u958b\u59cb1\u5206\u304b\u3089\u9855\u8457\u306a\u5f71\u97ff\u304c\u898b\u3089\u308c\u300110\u5206\u305f\u3064\u3053\u308d\u306b\u306f\u6c34\u9762\u306b\u306f\u307b\u3068\u3093\u3069\u7d30\u80de\u304c\u3044\u306a\u3044\u3068\u3044\u3046\u7d50\u679c\u306b\u306a\u308a\u307e\u3057\u305f\uff08\u56f34\u2460\uff09\u3002\u4e00\u65b9\u3067\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306f15\u5206\u304f\u3089\u3044\u307e\u3067\u3042\u307e\u308a\u5dee\u304c\u306a\u304b\u3063\u305f\u306e\u3067\u3059\u304c\u300130\u5206\u300160\u5206\u3068\u7d4c\u904e\u3059\u308b\u3054\u3068\u306b\u7d30\u80de\u6fc3\u5ea6\u304c\u5927\u304d\u304f\u4e0a\u6607\u3057\u307e\u3057\u305f\uff08\u56f34\u2462\uff09\u3002<\/p>\n<p>\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u5747\u4e00\u306a\u6fc3\u5ea6\u306b\u3059\u308b\u3053\u3068\u306f\u3001\u518d\u73fe\u6027\u306e\u3042\u308b\u5b9f\u9a13\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u3068\u3066\u3082\u91cd\u8981\u3067\u3059\u3002\u4eca\u56de\u306e\u7d50\u679c\u304b\u3089\u3001\u30c1\u30e5\u30fc\u30d6\u306e\u6c34\u9762\u306f\u7279\u306b\u653e\u7f6e\u3057\u305f\u969b\u306e\u7d30\u80de\u6fc3\u5ea6\u3078\u306e\u5f71\u97ff\u304c\u5927\u304d\u3044\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\u3002\u5f53\u7136\u306a\u304c\u3089\u3001\u6c88\u6bbf\u3057\u305f\u5f8c\u306b\u518d\u5ea6\u30d4\u30da\u30c3\u30c8\u3067\u6df7\u5408\u3057\u305f\u5834\u5408\u306b\u306f\u6c34\u9762\u3067\u3082\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u3067\u3082\u540c\u7b49\u306e\u7d30\u80de\u6fc3\u5ea6\u3068\u306a\u308a\u307e\u3059\uff08Data not shown\uff09\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u3067\u3057\u3087\u3046\u304b\u3002\u4eca\u56de\u306e\u5b9f\u9a13\u7cfb\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u6642\u306b\u6db2\u304c\u5c11\u3057\u304b\u304d\u6df7\u3056\u3063\u3066\u3057\u307e\u3063\u305f\u53ef\u80fd\u6027\u3084\u3001\u63a1\u53d6\u306b\u3088\u308a\u6db2\u91cf\u304c\u6e1b\u3063\u3066\u3044\u3063\u305f\u3053\u3068\u3082\u3042\u308a\u6b63\u78ba\u306a\u30c7\u30fc\u30bf\u3067\u306f\u306a\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u304c\u3001\u304a\u304a\u307e\u304b\u306a\u50be\u5411\u306f\u9593\u9055\u3063\u3066\u3044\u306a\u3044\u306e\u3067\u306f\u3068\u601d\u3044\u307e\u3059\u3002<br \/>\n\u7686\u3055\u307e\u3082\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u53d6\u308a\u6271\u3046\u969b\u306f\u3001\u3057\u3063\u304b\u308a\u6df7\u5408\u3059\u308b\u3001\u6c34\u9762\u304b\u3089\u306f\u53d6\u3089\u306a\u3044\u3001\u3068\u3044\u3046\u3053\u3068\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<br \/>\n\u4eca\u56de\u5408\u8a08\u306796\u30b5\u30f3\u30d7\u30eb\u3082\u306e\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u3092\u884c\u3044\u307e\u3057\u305f\u304c\u3001Countess 3\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306e\u304a\u304b\u3052\u3067\u3042\u307e\u308a\u82e6\u52b4\u305b\u305a\u306b\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002Countess 3\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306e\u8a73\u7d30\u60c5\u5831\u3084\u30c7\u30e2\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u3069\u3046\u305e\u304a\u6c17\u8efd\u306b\u4e0b\u8a18\u306e\u30dc\u30bf\u30f3\u304b\u3089\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><b>Countess 3 \/ 3 FL \u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc \u30c7\u30e2\u4f9d\u983c\u3001\u898b\u7a4d\u3082\u308a\u3001\u8cc7\u6599\u8acb\u6c42\u30d5\u30a9\u30fc\u30e0<\/b><\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/cell-analysis-instruments\/automated-cell-counters\/countess-inquiry.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_count_workshop_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>\u5f53\u793e\u3067\u306f\u7d30\u80de\u57f9\u990a\u3092\u306f\u3058\u3081\u3001\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u3084\u86cd\u5149\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3001\u30b2\u30ce\u30e0\u7de8\u96c6\u306a\u3069\u3001\u5b9f\u969b\u306b\u5b9f\u9a13\uff08\u5b9f\u7fd2\uff09\u3092\u884c\u3044\u3064\u3064\u5b66\u3079\u308b<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_count_workshop_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/a>\u3092\u5404\u7a2e\u958b\u50ac\u3057\u3066\u3044\u307e\u3059\u3002<br \/>\n\u305d\u306e\u4e2d\u3067\u4eca\u56de\u306e\u3088\u3046\u306a\u5b9f\u9a13\u7d50\u679c\u3082\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u3053\u308c\u304b\u3089\u65b0\u3057\u3044\u5b9f\u9a13\u3092\u59cb\u3081\u3089\u308c\u308b\u65b9\u3001\u3088\u308a\u7406\u89e3\u3092\u6df1\u3081\u305f\u3044\u65b9\u306f\u305c\u3072\u3054\u53c2\u52a0\u304f\u3060\u3055\u3044\uff01<\/p>\n<p>\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u4e00\u89a7\u30da\u30fc\u30b8\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/lifescience-training.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_count_workshop_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a><\/p>\n<p>\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_cce_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_cell_count_workshop_bid_ts_1_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u7d30\u80de\u57f9\u990a\u3092\u3055\u308c\u3066\u3044\u308b\u65b9\u306f\u3001\u7d30\u80de\u306e\u61f8\u6fc1\u6db2\u3092\u3046\u3063\u304b\u308a\u653e\u7f6e\u3057\u3066\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306b\u7d30\u80de\u304c\u6c88\u3093\u3067\u3057\u307e\u3046\u3053\u3068\u3092\u7d4c\u9a13\u3055\u308c\u3066\u3044\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u77ed\u6642\u9593\u3067\u3042\u3063\u3066\u3082\u591a\u5c11\u306f\u6c88\u6bbf\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u3001\u653e\u7f6e\u3057\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306f\u3057\u3063\u304b\u308a\u3068\u6df7\u5408\u3057\u3066\u7d30\u80de\u6fc3\u5ea6\u3092\u5747\u4e00<\/p>\n","protected":false},"author":975,"featured_media":15959,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[28,97],"division":[],"class_list":["post-15949","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-experiment","tag-cell-count","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f\" \/>\n<meta property=\"og:description\" content=\"\u7d30\u80de\u57f9\u990a\u3092\u3055\u308c\u3066\u3044\u308b\u65b9\u306f\u3001\u7d30\u80de\u306e\u61f8\u6fc1\u6db2\u3092\u3046\u3063\u304b\u308a\u653e\u7f6e\u3057\u3066\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306b\u7d30\u80de\u304c\u6c88\u3093\u3067\u3057\u307e\u3046\u3053\u3068\u3092\u7d4c\u9a13\u3055\u308c\u3066\u3044\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u77ed\u6642\u9593\u3067\u3042\u3063\u3066\u3082\u591a\u5c11\u306f\u6c88\u6bbf\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u3001\u653e\u7f6e\u3057\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306f\u3057\u3063\u304b\u308a\u3068\u6df7\u5408\u3057\u3066\u7d30\u80de\u6fc3\u5ea6\u3092\u5747\u4e00\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2023-12-25T03:02:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-25T06:57:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"334\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"9\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f\",\"datePublished\":\"2023-12-25T03:02:17+00:00\",\"dateModified\":\"2024-12-25T06:57:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/\"},\"wordCount\":92,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/shutterstock_58307962.jpg\",\"keywords\":[\"\u3084\u3063\u3066\u307f\u305f\",\"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/shutterstock_58307962.jpg\",\"datePublished\":\"2023-12-25T03:02:17+00:00\",\"dateModified\":\"2024-12-25T06:57:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/shutterstock_58307962.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/12\\\/shutterstock_58307962.jpg\",\"width\":500,\"height\":334},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-count-workshop-bid-ts-1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f","og_description":"\u7d30\u80de\u57f9\u990a\u3092\u3055\u308c\u3066\u3044\u308b\u65b9\u306f\u3001\u7d30\u80de\u306e\u61f8\u6fc1\u6db2\u3092\u3046\u3063\u304b\u308a\u653e\u7f6e\u3057\u3066\u30c1\u30e5\u30fc\u30d6\u306e\u5e95\u306b\u7d30\u80de\u304c\u6c88\u3093\u3067\u3057\u307e\u3046\u3053\u3068\u3092\u7d4c\u9a13\u3055\u308c\u3066\u3044\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u77ed\u6642\u9593\u3067\u3042\u3063\u3066\u3082\u591a\u5c11\u306f\u6c88\u6bbf\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u3001\u653e\u7f6e\u3057\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306f\u3057\u3063\u304b\u308a\u3068\u6df7\u5408\u3057\u3066\u7d30\u80de\u6fc3\u5ea6\u3092\u5747\u4e00","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2023-12-25T03:02:17+00:00","article_modified_time":"2024-12-25T06:57:27+00:00","og_image":[{"width":500,"height":334,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"9\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f","datePublished":"2023-12-25T03:02:17+00:00","dateModified":"2024-12-25T06:57:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/"},"wordCount":92,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg","keywords":["\u3084\u3063\u3066\u307f\u305f","\u7d30\u80de\u30ab\u30a6\u30f3\u30c8"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg","datePublished":"2023-12-25T03:02:17+00:00","dateModified":"2024-12-25T06:57:27+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg","width":500,"height":334},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-count-workshop-bid-ts-1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u304c\u30c1\u30e5\u30fc\u30d6\u306e\u4e2d\u3067\u6c88\u3080\u901f\u5ea6\u3092\u6e2c\u3063\u3066\u307f\u305f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":28,"label":"\u3084\u3063\u3066\u307f\u305f"},{"value":97,"label":"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg",500,334,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":28,"name":"\u3084\u3063\u3066\u307f\u305f","slug":"experiment","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":73,"filter":"raw","meta":[]},{"term_id":97,"name":"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8","slug":"cell-count","term_group":0,"term_taxonomy_id":97,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/12\/shutterstock_58307962.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15949","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=15949"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/15949\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/15959"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=15949"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=15949"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=15949"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=15949"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}