{"id":17004,"date":"2024-05-02T17:32:57","date_gmt":"2024-05-02T08:32:57","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=17004"},"modified":"2024-12-04T15:03:59","modified_gmt":"2024-12-04T06:03:59","slug":"sanger-seq-ce-gsd-ts-ce-24024","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/","title":{"rendered":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5"},"content":{"rendered":"<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u7d50\u679c\u3001\u5869\u57fa\u914d\u5217\u3092\u89e3\u8aad\u3067\u304d\u306a\u304b\u3063\u305f\u5834\u5408\u3001\u8003\u3048\u3089\u308c\u308b\u8981\u56e0\u306e\u3072\u3068\u3064\u306b\u3001\u5341\u5206\u306a\u5f37\u5ea6\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u5f97\u3089\u308c\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u3042\u3052\u3089\u308c\u307e\u3059\u3002\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306e\u78ba\u8a8d\u65b9\u6cd5\u3068\u3001\u5f37\u5ea6\u304c\u5341\u5206\u3067\u306a\u304b\u3063\u305f\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u3092\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306e\u78ba\u8a8d\u65b9\u6cd5<\/h2>\n<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306f\u3001Applied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A38938?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_gsd_ts_ce_24024_Social_LAB\" rel=\"noopener\" target=\"_blank\">Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/a>\u3001\u307e\u305f\u306f\u3001Thermo Fisher\u2122 Connect Platform\u306e\u30a2\u30d7\u30ea\u3067\u3042\u308bQuality Check\u304b\u3089\u3054\u78ba\u8a8d\u3044\u305f\u3060\u3051\u307e\u3059\u3002\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u304b\u3089\u306e\u30c7\u30fc\u30bf\u78ba\u8a8d\u624b\u9806\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002Quality Check\u3067\u306e\u78ba\u8a8d\u65b9\u6cd5\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ce_app_gsd_ts_2\/?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_gsd_ts_ce_24024_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u3053\u3061\u3089<\/a>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u8d77\u52d5\u3057\u3001\u56f3\uff11\u306e\u624b\u9806\u3067\u3001\u30c7\u30fc\u30bf\u3092\u78ba\u8a8d\u3057\u305f\u3044\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\uff08.ab1\uff09\u3092\u8aad\u307f\u8fbc\u307f\u307e\u3059\u3002\u300cShow\u300d\u306e\u30c1\u30a7\u30c3\u30af\u30dc\u30c3\u30af\u30b9\u3092\u30af\u30ea\u30c3\u30af\u3057\u3001Raw\u30bf\u30d6\u3092\u9078\u629e\u3057\u307e\u3059\uff08\u56f32\uff09\u3002\u8868\u793a\u3055\u308c\u308bRaw Data\u306e\u30d4\u30fc\u30af\u9ad8\u306f\u3001\u30b8\u30a7\u30cd\u30c6\u30a3\u30c3\u30af\u30a2\u30ca\u30e9\u30a4\u30b6\u3067\u691c\u51fa\u3055\u308c\u305f\u86cd\u5149\u30b7\u30b0\u30ca\u30eb\u306e\u5f37\u5ea6\u3092\u793a\u3057\u307e\u3059\u3002\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u304c\u3046\u307e\u304f\u3044\u304b\u306a\u304b\u3063\u305f\u5834\u5408\u3001\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u9069\u5207\u3067\u306a\u3044\u6050\u308c\u304c\u3042\u308a\u307e\u3059\u3002\u4f4e\u30b7\u30b0\u30ca\u30eb\u3001\u307e\u305f\u306f\u3001\u30b7\u30b0\u30ca\u30eb\u304c\u306a\u3044\u5834\u5408\u306e\u30c7\u30fc\u30bf\u4f8b\u3001\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u3092\u3001\u4ee5\u4e0b\u306b\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<br \/>\n\u306a\u304a\u3001Electropherogram\u30bf\u30d6\u304b\u3089\u306f\u3001Raw Data\u3092\u88dc\u6b63\u3057\u305f\u6ce2\u5f62\u3067\u3042\u308bElectropherogram\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><div id=\"attachment_17009\" style=\"width: 603px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/a05eef8709d0f947e5a8672a8d4ec34a.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17009\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/a05eef8709d0f947e5a8672a8d4ec34a.jpg\" alt=\"\u56f31. Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\u306e\u8aad\u307f\u8fbc\u307f\" width=\"593\" height=\"535\" class=\"size-full wp-image-17009\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/a05eef8709d0f947e5a8672a8d4ec34a.jpg 1884w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/a05eef8709d0f947e5a8672a8d4ec34a-300x270.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/a05eef8709d0f947e5a8672a8d4ec34a-1024x922.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/a05eef8709d0f947e5a8672a8d4ec34a-768x691.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/a05eef8709d0f947e5a8672a8d4ec34a-1536x1383.jpg 1536w\" sizes=\"auto, (max-width: 593px) 100vw, 593px\" \/><\/a><p id=\"caption-attachment-17009\" class=\"wp-caption-text\">\u56f31. Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u30d5\u30a1\u30a4\u30eb\u306e\u8aad\u307f\u8fbc\u307f<br \/>\u203b\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u5927\u304d\u306a\u753b\u50cf\u304c\u8868\u793a\u3055\u308c\u307e\u3059<\/p><\/div><br \/>\n<div id=\"attachment_17010\" style=\"width: 2400px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17010\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66.jpg\" alt=\"\u56f32. Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u304b\u3089\u306eRaw Data\u306e\u78ba\u8a8d\" width=\"2390\" height=\"1416\" class=\"size-full wp-image-17010\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66.jpg 2390w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66-300x178.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66-1024x607.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66-768x455.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66-1536x910.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/e2f761f64d66fe21a6c58deeb41c0e66-2048x1213.jpg 2048w\" sizes=\"auto, (max-width: 2390px) 100vw, 2390px\" \/><\/a><p id=\"caption-attachment-17010\" class=\"wp-caption-text\">\u56f32. Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u304b\u3089\u306eRaw Data\u306e\u78ba\u8a8d<br \/>\u203b\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u5927\u304d\u306a\u753b\u50cf\u304c\u8868\u793a\u3055\u308c\u307e\u3059<\/p><\/div><\/p>\n<h2>\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u7269\u7531\u6765\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u306a\u3044\u5834\u5408<\/h2>\n<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u7269\u7531\u6765\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u3001Raw Data\u3067\u306f\u3001\u56f33\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u30d4\u30fc\u30af\u304c\u307f\u3089\u308c\u305a\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u307f\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30d4\u30fc\u30af\u304c\u306a\u3044\u305f\u3081\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u304c\u62e1\u5927\u3055\u308c\u305f\u7e26\u8ef8\u8868\u793a\u306b\u306a\u3063\u3066\u304a\u308a\u3001\u7e26\u8ef8\u306e\u6570\u5024\u3092\u78ba\u8a8d\u3059\u308b\u3068\u30010\u4ed8\u8fd1\u3092\u63a8\u79fb\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u3053\u306e\u3068\u304d\u3001Electropherogram\u3067\u306f\u3001\u4e0d\u898f\u5247\u306a\u6ce2\u5f62\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30c8\u30e9\u30d6\u30eb\u306e\u539f\u56e0\u3092\u6b63\u3057\u304f\u628a\u63e1\u3059\u308b\u305f\u3081\u306b\u3001Raw Data\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n<div id=\"attachment_17011\" style=\"width: 1465px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/40d7122d72a8a129faf249dc2217efd3.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17011\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/40d7122d72a8a129faf249dc2217efd3.jpg\" alt=\"\u56f33. \u30b7\u30b0\u30ca\u30eb\u304c\u306a\u3044\u30c7\u30fc\u30bf\u4f8b\n\u4e0a\uff1aRaw Data\u3001\u4e0b\uff1aElectropherogram\" width=\"1455\" height=\"808\" class=\"size-full wp-image-17011\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/40d7122d72a8a129faf249dc2217efd3.jpg 1455w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/40d7122d72a8a129faf249dc2217efd3-300x167.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/40d7122d72a8a129faf249dc2217efd3-1024x569.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/40d7122d72a8a129faf249dc2217efd3-768x426.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/40d7122d72a8a129faf249dc2217efd3-450x250.jpg 450w\" sizes=\"auto, (max-width: 1455px) 100vw, 1455px\" \/><\/a><p id=\"caption-attachment-17011\" class=\"wp-caption-text\">\u56f33. \u30b7\u30b0\u30ca\u30eb\u304c\u306a\u3044\u30c7\u30fc\u30bf\u4f8b<br \/>\u4e0a\uff1aRaw Data\u3001\u4e0b\uff1aElectropherogram<br \/>\u203b\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u5927\u304d\u306a\u753b\u50cf\u304c\u8868\u793a\u3055\u308c\u307e\u3059<\/p><\/div>\n<p>\u30b7\u30b0\u30ca\u30eb\u304c\u306a\u3044\u5834\u5408\u306b\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n<table style=\"border-collapse: collapse;border-color: gray\" border=\"2\">\n<tbody>\n<tr bgcolor=\"silver\">\n<td style=\"text-align: center\" width=\"10\"><b>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0<\/b><\/td>\n<td style=\"text-align: center\" width=\"20\"><b>\u5bfe\u51e6\u6cd5<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u5931\u6557<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u30a6\u30a7\u30eb\u5185\u306e\u6db2\u91cf\u3092\u78ba\u8a8d\u3057\u3001\u5c11\u306a\u3044\u5834\u5408\u306f\u5341\u5206\u306a\u91cf\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u518d\u8abf\u88fd\u3059\u308b\uff08\u203b1\uff09<br \/>\n\u30fb\u4f7f\u7528\u3057\u305f\u30e9\u30f3\u30e2\u30b8\u30e5\u30fc\u30eb\u304c\u9069\u5207\u304b\u78ba\u8a8d\u3059\u308b\uff08\u203b2\uff09<br \/>\n\u30fb\u6307\u5b9a\u306e\u30d7\u30ec\u30fc\u30c8\u30fb8\u9023\u30c1\u30e5\u30fc\u30d6\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u304b\u78ba\u8a8d\u3059\u308b<br \/>\n\u30fb\u30ad\u30e3\u30d4\u30e9\u30ea\u304c\u7834\u640d\u3057\u3066\u3044\u306a\u3044\u304b\u78ba\u8a8d\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30b5\u30f3\u30d7\u30eb\u306e\u6eb6\u89e3\u306b\u6c34\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u84b8\u767a\u3057\u6db2\u91cf\u304c\u6e1b\u3063\u305f<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fbApplied Biosystems\u2122 Hi-Di\u2122 Formamide\u3092\u4f7f\u7528\u3057\u3066\u30b5\u30f3\u30d7\u30eb\u3092\u518d\u8abf\u88fd\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30ad\u30e3\u30d4\u30e9\u30ea\u304c\u7834\u640d\u3057\u3066\u3044\u308b<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u30ad\u30e3\u30d4\u30e9\u30ea\u3092\u78ba\u8a8d\u3057\u3001\u7834\u640d\u304c\u898b\u3064\u304b\u3063\u305f\u5834\u5408\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30a2\u30ec\u30a4\u3092\u4ea4\u63db\u3059\u308b<br \/>\n\u30fb\u540c\u3058\u30ad\u30e3\u30d4\u30e9\u30ea\u306b\u7e70\u308a\u8fd4\u3057\u30a8\u30e9\u30fc\u304c\u898b\u3089\u308c\u308b\u5834\u5408\u3082\u4ea4\u63db\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u307e\u305f\u306f\u30b5\u30f3\u30d7\u30eb\u304c\u591a\u904e\u304e\u308b\u305f\u3081\u3001\u4e00\u6642\u7684\u306b\u30ad\u30e3\u30d4\u30e9\u30ea\u304c\u76ee\u8a70\u307e\u308a\u3057\u305f<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u30b5\u30f3\u30d7\u30eb\u3092\u518d\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u3059\u308b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u203b1\u300010 \u00b5L\u4ee5\u4e0a\u3002Applied Biosystems\u2122 BigDye\u2122 XTerminator\u2122 \u7cbe\u88fd\u30ad\u30c3\u30c8\u5c02\u7528\u306e\u30e9\u30f3\u30e2\u30b8\u30e5\u30fc\u30eb\u4f7f\u7528\u306e\u5834\u5408\u306f65 \u00b5L\u4ee5\u4e0a<br \/>\n\u203b2\u3000\u901a\u5e38\u306e\u30e9\u30f3\u30e2\u30b8\u30e5\u30fc\u30eb\u3092\u4f7f\u7528\u3059\u3079\u304d\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u3057\u3001\u8aa4\u3063\u3066BigDye XTerminator\u7cbe\u88fd\u30ad\u30c3\u30c8\u5c02\u7528\u306e\u30e9\u30f3\u30e2\u30b8\u30e5\u30fc\u30eb\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u306a\u3069<\/p>\n<h2>\u86cd\u5149\u30bf\u30fc\u30df\u30cd\u30fc\u30bf\u30fc\u306e\u30b7\u30b0\u30ca\u30eb\u306e\u307f\u306e\u5834\u5408<\/h2>\n<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3067\u306f\u3001\u86cd\u5149\u6a19\u8b58\u30b8\u30c7\u30aa\u30ad\u30b7\u30cc\u30af\u30ec\u30aa\u30c1\u30c9\uff08\u86cd\u5149\u30bf\u30fc\u30df\u30cd\u30fc\u30bf\u30fc\uff09\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u4f38\u9577\u7523\u7269\u306b\u86cd\u5149\u304c\u6a19\u8b58\u3055\u308c\u307e\u3059\u3002\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u304c\u3046\u307e\u304f\u3044\u304b\u305a\u3001\u53cd\u5fdc\u306b\u4f7f\u308f\u308c\u306a\u304b\u3063\u305f\u86cd\u5149\u30bf\u30fc\u30df\u30cd\u30fc\u30bf\u30fc\u304c\u591a\u304f\u6b8b\u5b58\u3057\u305f\u5834\u5408\u3001\u7cbe\u88fd\u306b\u3088\u308a\u9664\u53bb\u3057\u304d\u308c\u305a\u3001\u30d4\u30fc\u30af\u3068\u3057\u3066\u691c\u51fa\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\uff08\u56f34\uff09\u3002<\/p>\n<div id=\"attachment_17012\" style=\"width: 1557px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/add73bda5f42718728a9c354845ec1b7.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17012\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/add73bda5f42718728a9c354845ec1b7.jpg\" alt=\"\u56f34. \u86cd\u5149\u30bf\u30fc\u30df\u30cd\u30fc\u30bf\u30fc\u306e\u307f\u306e\u30c7\u30fc\u30bf\u4f8b\n\u4e0a\uff1aRaw Data\u3001\u4e0b\uff1aElectropherogram\" width=\"1547\" height=\"880\" class=\"size-full wp-image-17012\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/add73bda5f42718728a9c354845ec1b7.jpg 1547w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/add73bda5f42718728a9c354845ec1b7-300x171.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/add73bda5f42718728a9c354845ec1b7-1024x582.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/add73bda5f42718728a9c354845ec1b7-768x437.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/add73bda5f42718728a9c354845ec1b7-1536x874.jpg 1536w\" sizes=\"auto, (max-width: 1547px) 100vw, 1547px\" \/><\/a><p id=\"caption-attachment-17012\" class=\"wp-caption-text\">\u56f34. \u86cd\u5149\u30bf\u30fc\u30df\u30cd\u30fc\u30bf\u30fc\u306e\u307f\u306e\u30c7\u30fc\u30bf\u4f8b<br \/>\u4e0a\uff1aRaw Data\u3001\u4e0b\uff1aElectropherogram<br \/>\u203b\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u5927\u304d\u306a\u753b\u50cf\u304c\u8868\u793a\u3055\u308c\u307e\u3059<\/p><\/div>\n<p>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n<table style=\"border-collapse: collapse;border-color: gray\" border=\"2\">\n<tbody>\n<tr bgcolor=\"silver\">\n<td style=\"text-align: center\" width=\"10\"><b>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0<\/b><\/td>\n<td style=\"text-align: center\" width=\"20\"><b>\u5bfe\u51e6\u6cd5<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u91cf\u304c\u5c11\u306a\u3044\u305f\u3081\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u304c\u5c11\u306a\u304f\u306a\u308a\u3059\u304e\u3066\u3044\u308b<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fbDNA\u306e\u6fc3\u5ea6\u3068\u54c1\u8cea\u3092\u78ba\u8a8d\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u8a66\u85ac\u306e\u3044\u305a\u308c\u304b\u3092\u5165\u308c\u5fd8\u308c\u3066\u3044\u308b\u3001\u307e\u305f\u306f\u52a3\u5316\u3057\u3066\u3044\u308b<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u5b9f\u9a13\u624b\u9806\u3092\u78ba\u8a8d\u3059\u308b<br \/>\n\u30fb\u8a66\u85ac\u306e\u6fc3\u5ea6\u3068\u54c1\u8cea\u3092\u78ba\u8a8d\u3059\u308b<br \/>\n\u30fb\u30b3\u30f3\u30c8\u30ed\u30fc\u30ebDNA\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3068\u30d7\u30e9\u30a4\u30de\u30fc\uff08\u203b3\uff09\u3092\u7528\u3044\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u304c\u5931\u6557\u3057\u3066\u3044\u308b\u306e\u304b\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3084\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u54c1\u8cea\u304c\u4f4e\u3044\u306e\u304b\u3092\u5224\u65ad\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306b\u30d5\u30a7\u30ce\u30fc\u30eb\u306a\u3069\u306e\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u963b\u5bb3\u7269\u8cea\u304c\u542b\u307e\u308c\u3066\u3044\u308b<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u63a8\u5968\u3055\u308c\u308b\u624b\u9806\u306b\u5f93\u3044\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u8abf\u88fd\u3059\u308b<br \/>\n\u30fbDNA\u54c1\u8cea\u3092\u78ba\u8a8d\u3059\u308b<br \/>\n\u30fb\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u7cbe\u88fd\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u8a2d\u8a08\u304c\u60aa\u3044\u305f\u3081\u3001\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u3055\u308c\u306a\u3044<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u65b0\u3057\u3044\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u4f5c\u6210\u3057\u3001\u5b9f\u9a13\u3092\u3084\u308a\u76f4\u3059<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u306e\u7cbe\u88fd\u6642\u306e\u30ed\u30b9<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u306e\u7cbe\u88fd\u624b\u9806\u3092\u898b\u76f4\u3059<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u203b3 \u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30ad\u30c3\u30c8\u306b\u306f\u3001\u30b3\u30f3\u30c8\u30ed\u30fc\u30ebDNA\u3068\u30d7\u30e9\u30a4\u30de\u30fc\u304c\u4ed8\u5c5e\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u5931\u6557\u306e\u539f\u56e0\u304c\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3084\u30d7\u30e9\u30a4\u30de\u30fc\u306b\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u5224\u65ad\u3057\u3084\u3059\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<h2>\u5168\u4f53\u7684\u306b\u4f4e\u30b7\u30b0\u30ca\u30eb\u306e\u5834\u5408<\/h2>\n<p>Raw Data\u3067\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u7523\u7269\u7531\u6765\u306e\u30d4\u30fc\u30af\u304c\u691c\u51fa\u3055\u308c\u3066\u3044\u308b\u3082\u306e\u306e\u3001\u305d\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u4f4e\u3044\u5834\u5408\uff08\u56f35\uff09\u3001\u826f\u597d\u306a\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u305b\u3093\u3002\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306fRaw Data\u304b\u3089\u3082\u78ba\u8a8d\u3067\u304d\u307e\u3059\u304c\u3001Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u300cAnnotation\u300d\u30bf\u30d6\u306b\u793a\u3055\u308c\u308b\u300cAve Signal Intensity\u300d\u3067\u3082\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002Ave Signal Intensity\u306b\u306f\u3001\u5869\u57fa\u3054\u3068\u306e\u5e73\u5747\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u8868\u793a\u3055\u308c\u3001\u3053\u306e\u6570\u5024\u304c1\uff5e2\u6841\u306e\u5834\u5408\u3001\u30b7\u30b0\u30ca\u30eb\u304c\u4e0d\u5341\u5206\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<div id=\"attachment_17013\" style=\"width: 1484px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/c327cead42e55b0aaf18c0e1061a4d69.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17013\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/c327cead42e55b0aaf18c0e1061a4d69.jpg\" alt=\"\u56f35. \u4f4e\u30b7\u30b0\u30ca\u30eb\u306e\u30c7\u30fc\u30bf\u4f8b\n\u4e0a\uff1aRaw Data\u3001\u4e0b\uff1aElectropherogram\" width=\"1474\" height=\"978\" class=\"size-full wp-image-17013\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/c327cead42e55b0aaf18c0e1061a4d69.jpg 1474w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/c327cead42e55b0aaf18c0e1061a4d69-300x199.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/c327cead42e55b0aaf18c0e1061a4d69-1024x679.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/c327cead42e55b0aaf18c0e1061a4d69-768x510.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/04\/c327cead42e55b0aaf18c0e1061a4d69-96x65.jpg 96w\" sizes=\"auto, (max-width: 1474px) 100vw, 1474px\" \/><\/a><p id=\"caption-attachment-17013\" class=\"wp-caption-text\">\u56f35. \u4f4e\u30b7\u30b0\u30ca\u30eb\u306e\u30c7\u30fc\u30bf\u4f8b<br \/>\u4e0a\uff1aRaw Data\u3001\u4e0b\uff1aElectropherogram<br \/>\u203b\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u5927\u304d\u306a\u753b\u50cf\u304c\u8868\u793a\u3055\u308c\u307e\u3059<\/p><\/div>\n<p>\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u5341\u5206\u3067\u306a\u3044\u5834\u5408\u3001\u4e0b\u8a18\u306e\u539f\u56e0\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<table style=\"border-collapse: collapse;border-color: gray\" border=\"2\">\n<tbody>\n<tr bgcolor=\"silver\">\n<td style=\"text-align: center\" width=\"10\"><b>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0<\/b><\/td>\n<td style=\"text-align: center\" width=\"20\"><b>\u5bfe\u51e6\u6cd5<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u304c\u5931\u6557<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u30b3\u30f3\u30c8\u30ed\u30fc\u30ebDNA\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3068\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u4f7f\u7528\u3057\u3066\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3092\u884c\u3044\u3001\u539f\u56e0\u3092\u8003\u5bdf\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">Ready Reaction Mix\u306e\u91cf\u304c\u4e0d\u5341\u5206<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fbReady Reaction Mix\u3092\u5e0c\u91c8\u3057\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u6a19\u6e96\u30d7\u30ed\u30c8\u30b3\u30eb\u3067\u53cd\u5fdc\u6db2\u3092\u8abf\u88fd\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u307e\u305f\u306f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u91cf\u304c\u4e0d\u5341\u5206<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fbDNA\u91cf\u3092\u78ba\u8a8d\u3057\u3001\u63a8\u5968\u3055\u308c\u308b\u91cf\uff08\u203b4\uff09\u3092\u4f7f\u7528\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u54c1\u8cea\u304c\u4f4e\u3044<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u63a8\u5968\u3055\u308c\u308b\u624b\u9806\u306b\u5f93\u3044\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u8abf\u88fd\u3059\u308b<br \/>\n\u30fbDNA\u306e\u54c1\u8cea\u3092\u78ba\u8a8d\u3059\u308b<br \/>\n\u30fb\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u7cbe\u88fd\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u306e\u7cbe\u88fd\u6642\u306e\u30ed\u30b9<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fb\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u306e\u7cbe\u88fd\u624b\u9806\u3092\u898b\u76f4\u3059<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306b\u542b\u307e\u308c\u308b\u5869\u306b\u3088\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u304c\u963b\u5bb3\u3055\u308c\u3066\u3044\u308b\uff08\u7cbe\u88fd\u306e\u4e0d\u5341\u5206\u306a\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3001PCR\u7523\u7269\u304b\u3089\u306e\u5869\u306e\u6b8b\u7559\u3001\u307e\u305f\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u5f8c\u306e\u30a8\u30bf\u30ce\u30fc\u30eb\u6c88\u6bbf\u7269\u306e\u5869\u306e\u6b8b\u7559\uff09<\/td>\n<td style=\"text-align: left\" width=\"20\">\u30fbDNA\u54c1\u8cea\u3001PCR\u7cbe\u88fd\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u7cbe\u88fd\u624b\u9806\u3092\u78ba\u8a8d\u3059\u308b<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u203b4\u3000\u30b5\u30a4\u30af\u30eb\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3067\u63a8\u5968\u3055\u308c\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u91cf\u306f\u30013.2 pmol\u3067\u3059\u3002\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u63a8\u5968\u4f7f\u7528\u91cf\u306f\u3001\u4e0b\u8868\u306e\u3068\u304a\u308a\u3067\u3059\u3002<\/p>\n<table style=\"border-collapse: collapse;border-color: silver\" border=\"2\">\n<tbody>\n<tr bgcolor=\"white\">\n<td style=\"text-align: center\" width=\"10\" colspan=\"2\"><b>DNA template<\/b><\/td>\n<td style=\"text-align: center\" width=\"10\"><b>Quantity<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\" rowspan=\"5\">&emsp;PCR product<\/td>\n<td style=\"text-align: left\" width=\"10\">&emsp;100\uff5e200 bp<\/td>\n<td style=\"text-align: center\" width=\"10\">1\uff5e3 ng<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">&emsp;200\uff5e500 bp<\/td>\n<td style=\"text-align: center\" width=\"10\">3\uff5e10 ng<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">&emsp;500\uff5e1,000 bp<\/td>\n<td style=\"text-align: center\" width=\"10\">5\uff5e20 ng<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">&emsp;1,000\uff5e2,000 bp<\/td>\n<td style=\"text-align: center\" width=\"10\">10\uff5e40 ng<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\">&emsp; &gt; 2,000 bp<\/td>\n<td style=\"text-align: center\" width=\"10\">20\uff5e50 ng<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\" colspan=\"2\">&emsp;Single-stranded DNA<\/td>\n<td style=\"text-align: center\" width=\"10\">25\uff5e50 ng<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\" colspan=\"2\">&emsp;Double-stranded DNA<\/td>\n<td style=\"text-align: center\" width=\"10\">150\uff5e300 ng<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\" colspan=\"2\">&emsp;Cosmid, BAC<\/td>\n<td style=\"text-align: center\" width=\"10\">0.5\uff5e1.0 \u00b5g<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"10\" colspan=\"2\">&emsp;Bacterial genomic DNA<\/td>\n<td style=\"text-align: center\" width=\"10\">2\uff5e3 \u00b5g<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u304c\u3046\u307e\u304f\u3044\u304b\u306a\u3044\u5834\u5408\u3001\u3055\u307e\u3056\u307e\u306a\u8981\u56e0\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30b7\u30b0\u30ca\u30eb\u304c\u4f4e\u3044\u5834\u5408\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u4ed6\u306e\u8981\u56e0\u306b\u3064\u3044\u3066\u3082\u3001\u4eca\u5f8c\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304f\u4e88\u5b9a\u3067\u3059\u3002<br \/>\n\u30ad\u30e3\u30d4\u30e9\u30ea\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308b\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u3064\u3044\u3066\u3001\u3088\u308a\u8a73\u3057\u304f\u77e5\u308a\u305f\u3044\u65b9\u306f\u3001\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u672c\u539f\u5247\u3092\u5b66\u3079\u308b\u8cc7\u6599\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u3051\u307e\u3059\u3002\u307e\u305f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u57fa\u790e\u30bb\u30df\u30ca\u30fc\u3084\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3082\u3054\u3056\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n<h3>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3000\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_gsd_ts_ce_24024_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h3>\u30bb\u30df\u30ca\u30fc\u3001\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/dna-sequencing.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_gsd_ts_ce_24024_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u57fa\u790e\u30bb\u30df\u30ca\u30fc\uff081\uff09\u57fa\u672c\u539f\u7406<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/dna-sequencing2.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_gsd_ts_ce_24024_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u57fa\u790e\u30bb\u30df\u30ca\u30fc\uff082\uff09\u30c7\u30fc\u30bf\u78ba\u8a8d\u3068\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/ab-dna-sequencing3130-3130xL.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_gsd_ts_ce_24024_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u5b8c\u5168\u30de\u30b9\u30bf\u30fc\uff01\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30b3\u30fc\u30b9\u3000\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5(1) \u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u304b\u3089\u30c7\u30fc\u30bf\u78ba\u8a8d\u307e\u3067<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u7d50\u679c\u3001\u5869\u57fa\u914d\u5217\u3092\u89e3\u8aad\u3067\u304d\u306a\u304b\u3063\u305f\u5834\u5408\u3001\u8003\u3048\u3089\u308c\u308b\u8981\u56e0\u306e\u3072\u3068\u3064\u306b\u3001\u5341\u5206\u306a\u5f37\u5ea6\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u5f97\u3089\u308c\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u3042\u3052\u3089\u308c\u307e\u3059\u3002\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306e\u78ba\u8a8d\u65b9\u6cd5\u3068\u3001\u5f37\u5ea6\u304c\u5341\u5206\u3067\u306a\u304b\u3063\u305f\u5834<\/p>\n","protected":false},"author":975,"featured_media":16634,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[172,183],"division":[],"class_list":["post-17004","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-ce","tag-sanger-seq","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u7d50\u679c\u3001\u5869\u57fa\u914d\u5217\u3092\u89e3\u8aad\u3067\u304d\u306a\u304b\u3063\u305f\u5834\u5408\u3001\u8003\u3048\u3089\u308c\u308b\u8981\u56e0\u306e\u3072\u3068\u3064\u306b\u3001\u5341\u5206\u306a\u5f37\u5ea6\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u5f97\u3089\u308c\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u3042\u3052\u3089\u308c\u307e\u3059\u3002\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306e\u78ba\u8a8d\u65b9\u6cd5\u3068\u3001\u5f37\u5ea6\u304c\u5341\u5206\u3067\u306a\u304b\u3063\u305f\u5834\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-05-02T08:32:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-04T06:03:59+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1637\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\",\"datePublished\":\"2024-05-02T08:32:57+00:00\",\"dateModified\":\"2024-12-04T06:03:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/\"},\"wordCount\":162,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/03\\\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg\",\"keywords\":[\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\",\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/\",\"name\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/03\\\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg\",\"datePublished\":\"2024-05-02T08:32:57+00:00\",\"dateModified\":\"2024-12-04T06:03:59+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/03\\\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/03\\\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg\",\"width\":2560,\"height\":1637},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-gsd-ts-ce-24024\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5","og_description":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u7d50\u679c\u3001\u5869\u57fa\u914d\u5217\u3092\u89e3\u8aad\u3067\u304d\u306a\u304b\u3063\u305f\u5834\u5408\u3001\u8003\u3048\u3089\u308c\u308b\u8981\u56e0\u306e\u3072\u3068\u3064\u306b\u3001\u5341\u5206\u306a\u5f37\u5ea6\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u5f97\u3089\u308c\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u3042\u3052\u3089\u308c\u307e\u3059\u3002\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u306e\u78ba\u8a8d\u65b9\u6cd5\u3068\u3001\u5f37\u5ea6\u304c\u5341\u5206\u3067\u306a\u304b\u3063\u305f\u5834","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-05-02T08:32:57+00:00","article_modified_time":"2024-12-04T06:03:59+00:00","og_image":[{"width":2560,"height":1637,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5","datePublished":"2024-05-02T08:32:57+00:00","dateModified":"2024-12-04T06:03:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/"},"wordCount":162,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg","keywords":["\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/","name":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg","datePublished":"2024-05-02T08:32:57+00:00","dateModified":"2024-12-04T06:03:59+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg","width":2560,"height":1637},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30c7\u30fc\u30bf\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u7121\u3044\u307e\u305f\u306f\u4f4e\u3044\u5834\u5408\u306e\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":172,"label":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"},{"value":183,"label":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-1024x655.jpg",760,486,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":172,"name":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","slug":"ce","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]},{"term_id":183,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","slug":"sanger-seq","term_group":0,"term_taxonomy_id":183,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/03\/9d384949b4e6955c6f40183a62f28ace-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/17004","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=17004"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/17004\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/16634"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=17004"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=17004"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=17004"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=17004"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}