{"id":172,"date":"2015-11-10T00:00:00","date_gmt":"2015-11-10T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/"},"modified":"2025-04-17T15:12:48","modified_gmt":"2025-04-17T06:12:48","slug":"qpcr-basic13","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/","title":{"rendered":"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de"},"content":{"rendered":"<p><br \/>\n\u5e74\u3005\u3001\u9032\u5316\u3057\u7d9a\u3051\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3002\u4e00\u6614\u524d\u306f\u5f53\u305f\u308a\u524d\u3060\u3063\u305f\u3084\u308a\u65b9\u304c\u3001\u5fc5\u305a\u3057\u3082\u6700\u9069\u3068\u306f\u8a00\u3044\u304d\u308c\u306a\u3044\u5834\u5408\u3082\u51fa\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u305d\u306e1\u3064\u306e\u4f8b\u304c\u3001\u691c\u91cf\u7dda\u6cd5\u3067\u3059\u3002<\/p>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3067\u691c\u91cf\u7dda\u3092\u3072\u304f\u5834\u5408\u3001\u5148\u305a\u306f\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u3092\u6e2c\u5b9a\u3057\u3001\u4f5c\u6210\u3057\u305f\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u30b5\u30f3\u30d7\u30eb\u691c\u91cf\u7dda\u3092\u3082\u3068\u306b\u30b5\u30f3\u30d7\u30eb\u306e\u5b9a\u91cf\u3092\u884c\u3044\u307e\u3059\uff08\u56f3\uff11\uff09\u3002<\/p>\n<div id=\"attachment_529\" style=\"width: 460px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic13-fig1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-529\" class=\"size-full wp-image-529\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic13-fig1.jpg\" alt=\"qpcr-basic13-fig1\" width=\"450\" height=\"258\" \/><\/a><p id=\"caption-attachment-529\" class=\"wp-caption-text\">\u56f31\uff1a\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u691c\u91cf\u7dda\u304b\u3089\u672a\u77e5\u30b5\u30f3\u30d7\u30eb\u306e\u6fc3\u5ea6\u3092\u6c42\u3081\u308b\u65b9\u6cd5\uff08\u691c\u91cf\u7dda\u6cd5\uff09<\/p><\/div>\n<p>\u3053\u306e\u3088\u3046\u306a\u691c\u91cf\u7dda\u6cd5\u306f\u3001\u5897\u5e45\u52b9\u7387\u3092\u53cd\u6620\u3059\u308b\u305f\u3081\u3001\u6b63\u78ba\u306a\u5b9a\u91cf\u7d50\u679c\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u8fd1\u5e74\u306f\u3001\u3088\u308a\u52b9\u7387\u7684\u306a\u5b9f\u9a13\u304c\u3067\u304d\u308b\u300c\u6bd4\u8f03C<sub>t<\/sub>\u6cd5\uff08\u22bf\u22bfC<sub>t<\/sub>\u6cd5\uff09\u300d\u304c\u3001\u691c\u91cf\u7dda\u6cd5\u306b\u4ee3\u308f\u3063\u3066\u7814\u7a76\u73fe\u5834\u3067\u3064\u304b\u308f\u308c\u308b\u30b1\u30fc\u30b9\u304c\u5897\u3048\u3066\u304d\u3066\u3044\u307e\u3059\u3002<br \/>\n\u6bd4\u8f03C<sub>t<\/sub>\u6cd5\u306e\u4e00\u756a\u306e\u7279\u5fb4\u306f\u3001\u300c\u691c\u91cf\u7dda\u3092\u3072\u304b\u306a\u304f\u3068\u3082\u826f\u3044\u300d\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u6e2c\u5b9a\u3092\u304a\u3053\u306a\u308f\u305a\u3001\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3067\u30b5\u30f3\u30d7\u30eb\u9593\u306e\u88dc\u6b63\u3092\u3057\u3001\u76f8\u5bfe\u5b9a\u91cf\u3057\u307e\u3059\u3002\u691c\u91cf\u7dda\u4f5c\u6210\u306e\u305f\u3081\u306b\u4f7f\u7528\u3059\u308b\u8a66\u85ac\u306e\u91cf\u3092\u6e1b\u3089\u3059\u3053\u3068\u304c\u3067\u304d\u3001\u5b9f\u9a13\u306e\u64cd\u4f5c\u3082\u5c11\u306a\u304f\u3066\u3059\u307f\u307e\u3059\u3002\u591a\u30b5\u30f3\u30d7\u30eb\u3092\u51e6\u7406\u3067\u304d\u308b\u30e1\u30ea\u30c3\u30c8\u3082\u3042\u308b\u306e\u3067\u3001\u30b3\u30c4\u3092\u304a\u3055\u3048\u3066\u3001\u305c\u3072\u6d3b\u7528\u3044\u305f\u3060\u304d\u305f\u3044\u3067\u3059\u3002<br \/>\n\u306a\u308b\u307b\u3069\u3002\u3067\u306f\u3001\u6bd4\u8f03C<sub>t<\/sub>\u6cd5\u306e\u539f\u7406\u3092\u307f\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n<p>\u6bd4\u8f03C<sub>t<\/sub>\u6cd5\u3068\u306f\u3001<strong>\u57fa\u6e96\u3068\u306a\u308b\u30b5\u30f3\u30d7\u30eb\uff08\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30bf\u30fc\uff09\u3068\u6bd4\u8f03\u3057\u3066\u3001\u672a\u77e5\u30b5\u30f3\u30d7\u30eb\u304c\u4f55\u30b5\u30a4\u30af\u30eb\u65e9\u304f\u3001\u3042\u308b\u3044\u306f\u4f55\u30b5\u30a4\u30af\u30eb\u9045\u304fThreshold Line\u306b\u5230\u9054\u3059\u308b\u304b\u3092\u691c\u51fa\u3057\u3001\u76f8\u5bfe\u5b9a\u91cf\u3059\u308b\u65b9\u6cd5\u3067\u3059\u3002<\/strong>\u691c\u91cf\u7dda\u6cd5\u3067\u5fc5\u8981\u3068\u3055\u308c\u308b\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u6e2c\u5b9a\u306f\u3044\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u305d\u3082\u305d\u3082\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9a\u91cf\u304c\u3001\u201c\u5897\u5e45\u7523\u7269\u304c\u3042\u308b\u91cf\u306b\u9054\u3059\u308b\u306e\u306b\u3001PCR\u3092\u4f55\u30b5\u30a4\u30af\u30eb\u304a\u3053\u306a\u3063\u305f\u304b\u304c\u308f\u304b\u308c\u3070\u3001\u521d\u671f\u91cf\u304c\u308f\u304b\u308b\u201d\u3068\u3044\u3046\u7406\u8ad6\u306b\u57fa\u3065\u304f\u3053\u3068\u3092\u899a\u3048\u3066\u3044\u307e\u3059\u304b?\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u521d\u671f\u91cf\u3092\u30b5\u30a4\u30af\u30eb\u6570\u3068\u3044\u3046\u3082\u306e\u3055\u3057\u3067\u8a08\u308b\u306e\u304c\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3002\u3064\u307e\u308a\u3001<strong>\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u9593\u3067PCR\u53cd\u5fdc\u30921\u30b5\u30a4\u30af\u30eb\u307e\u308f\u3059\u3053\u3068\u3067\u751f\u3058\u308b\u5897\u5e45\u7523\u7269\u306e\u91cf\u306e\u5dee\u306f\u3001\u521d\u671f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u91cf\u306e\u9055\u3044\u3092\u53cd\u6620\u3057\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n<p>\u3053\u3053\u3067\u5927\u4e8b\u306a\u306e\u306f\u3001<strong><u>PCR\u306e\u5897\u5e45\u52b9\u7387\u304c1\u3067\u3042\u308c\u3070\u3001\u5897\u5e45\u66f2\u7dda\u304c1\u30b5\u30a4\u30af\u30eb\u65e9\u304f\u7acb\u3061\u4e0a\u304c\u308b\u3053\u3068\u306f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u521d\u671f\u91cf\u304c2\u500d\u3067\u3042\u308b\u3001\u9006\u306b1\u30b5\u30a4\u30af\u30eb\u9045\u304f\u7acb\u3061\u4e0a\u304c\u308b\u3068\u3053\u3068\u306f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u521d\u671f\u91cf\u304c\u534a\u5206\u3067\u3042\u308b\u3001\u3068\u3044\u3046\u6cd5\u5247\u304c\u6210\u308a\u7acb\u3064<\/u><\/strong>\u3053\u3068\u3067\u3059\uff08\u56f32\uff09\u3002<\/p>\n<div id=\"attachment_531\" style=\"width: 460px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic13-fig2.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-531\" class=\"size-full wp-image-531\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic13-fig2.jpg\" alt=\"qpcr-basic13-fig2\" width=\"450\" height=\"229\" \/><\/a><p id=\"caption-attachment-531\" class=\"wp-caption-text\">\u56f32\uff1a\u521d\u671f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u91cf\u304c\u65e2\u77e5\u306e3\u3064\u306e\u30b5\u30f3\u30d7\u30eb\uff081,250\u30015,000\u300120,000\u30b3\u30d4\u30fc\uff09\u306b\u5bfe\u3059\u308b\u5897\u5e45\u66f2\u7dda\u3002Threshold Cycle(Ct)\u306f\u5404\u5897\u5e45\u66f2\u7dda\u306e\u9593\u9694\u304c2\u30b5\u30a4\u30af\u30eb\u305a\u3064\u7570\u306a\u3063\u3066\u3044\u308b\u3002\u3053\u306e\u3053\u3068\u304b\u3089\u3001\u5404\u3005\u30b5\u30f3\u30d7\u30eb\u306e\u521d\u671f\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u91cf\u304c2\u306e2\u4e57\u3001\u3064\u307e\u308a4\u500d\u305a\u3064\u7570\u306a\u308b\u3053\u3068\u304c\u308f\u304b\u308b\u3002<\/p><\/div>\n<p>\u6bd4\u8f03C<sub>t<\/sub>\u6cd5\u3067\u306f\u3001\u3053\u306e\u201c1\u30b5\u30a4\u30af\u30eb\u306e\u691c\u51fa\u306e\u9055\u3044\u304c\u30012\u500d\u91cf\u306e\u5dee\u3067\u3042\u308b\u201d\u3068\u3044\u3046\u7406\u8ad6\u3092\u3064\u304b\u3044\u3001\u5b9a\u91cf\u7d50\u679c\u30922\u30b5\u30a4\u30af\u30eb\u6570\u306e\u5dee\u500d\u3068\u3044\u3046\u5f0f\uff08\u5f0f\u2460\uff09\u3067\u6c42\u3081\u307e\u3059\u3002<\/p>\n<div class=\"box-c\">\n<p>$$2-\\Delta \\Delta { C }_{ t }\\cdots \\cdots \u5f0f\u2460$$<br \/>\n<span style=\"text-decoration: underline\"><strong>\u22bfC<sub>t<\/sub>\u3068\u22bf\u22bfC<sub>t<\/sub>\u306e\u6c42\u3081\u65b9<\/strong><\/span><\/p>\n<p>1. \u22bfC<sub>t<\/sub>\uff1d\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u00f7\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u907a\u4f1d\u5b50\uff08\u4e57\u6570\u306e\u5272\u308a\u7b97\u306f\u5f15\u304d\u7b97\uff09<br \/>\n\u2234\u22bfC<sub>t<\/sub>\uff1d\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50C<sub>t<\/sub>\uff0d\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30ebC<sub>t<\/sub><br \/>\n2. \u22bf\u22bfC<sub>t<\/sub>\uff1d\u5404\u30b5\u30f3\u30d7\u30eb\u00f7\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30bf\u30b5\u30f3\u30d7\u30eb\uff08\u4e57\u6570\u306e\u5272\u308a\u7b97\u306f\u5f15\u304d\u7b97\uff09<br \/>\n\u2234\u22bf\u22bfC<sub>t<\/sub>\uff1d\u5404\u30b5\u30f3\u30d7\u30eb\u22bfC<sub>t<\/sub>\uff0d\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30bf\u30b5\u30f3\u30d7\u30eb\u22bfC<sub>t<\/sub><\/p>\n<p>\u203b\u6bd4\u8f03C<sub>t<\/sub>\u6cd5\u304c\u6210\u7acb\u3059\u308b\u6761\u4ef6<\/p>\n<ul>\n<li>\u30bf\u30fc\u30b2\u30c3\u30c8\u907a\u4f1d\u5b50\u3068\u5185\u5728\u6027\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u907a\u4f1d\u5b50\u306ePCR\u52b9\u7387\u304c\u307b\u307c\u7b49\u3057\u3044\n<ul>\n<li>\u5e0c\u91c8\u306b\u3088\u3063\u3066\u22bfC<sub>t<\/sub>\u5024\u304c\u5909\u52d5\u3057\u306a\u3044\uff1d\u691c\u91cf\u7dda\u3092\u63cf\u3044\u305f\u6642\u306e\u50be\u304d\u304c\u540c\u3058<\/li>\n<\/ul>\n<\/li>\n<li>PCR\u52b9\u7387\u304c1\u306b\u8fd1\u3044\n<ul>\n<li>\u8a2d\u8a08\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u306b\u57fa\u3065\u304f\u3068PCR\u52b9\u7387\u306e\u4e0b\u304c\u3089\u306a\u3044\u77ed\u3044Amplicon\u30b5\u30a4\u30ba\u306e\u8a2d\u8a08\u304c\u53ef\u80fd<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>\u203b\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30bf\u30b5\u30f3\u30d7\u30eb\u306f\u3001\u523a\u6fc0\u524d\u30b5\u30f3\u30d7\u30eb\u30840\u6642\u9593\u30b5\u30f3\u30d7\u30eb\u306a\u3069\u76f8\u5bfe\u91cf\u306e\u57fa\u6e96\u306b\u3057\u305f\u3044\u30b5\u30f3\u30d7\u30eb\u30921\u3064\u8a2d\u5b9a<\/p>\n<\/div>\n<p>\u6b21\u56de\u306f\u3001\u5b9f\u969b\u306e\u5b9f\u9a13\u30c7\u30fc\u30bf\u3092\u53d6\u308a\u4e0a\u3052\u306a\u304c\u3089\u3001\u6bd4\u8f03C<sub>t<\/sub>\u6cd5\u3092\u6975\u3081\u307e\u3059\u3002\u304a\u697d\u3057\u307f\u306b!<\/p>\n<h2>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr13_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr13_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u691c\u91cf\u7dda\u3092\u3072\u304f\u305f\u3081\u306b\u5fc5\u8981\u306a\u3001\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u8abf\u6574\u3068\u6e2c\u5b9a\u3002\u3053\u306e\u30b3\u30b9\u30c8\u3092\u7701\u3044\u3066\u5b9a\u91cf\u3067\u304d\u308b\u4fbf\u5229\u306a\u65b9\u6cd5\u304c\u300c\u6bd4\u8f03Ct\u6cd5\u300d\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u6bd4\u8f03Ct\u6cd5\u3092\u653b\u7565\u3059\u308b\u305f\u3081\u306e\u7406\u8ad6\u3092\u304d\u3063\u3061\u308a\u304a\u3055\u3048\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2278,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-172","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de\" \/>\n<meta property=\"og:description\" content=\"\u691c\u91cf\u7dda\u3092\u3072\u304f\u305f\u3081\u306b\u5fc5\u8981\u306a\u3001\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u8abf\u6574\u3068\u6e2c\u5b9a\u3002\u3053\u306e\u30b3\u30b9\u30c8\u3092\u7701\u3044\u3066\u5b9a\u91cf\u3067\u304d\u308b\u4fbf\u5229\u306a\u65b9\u6cd5\u304c\u300c\u6bd4\u8f03Ct\u6cd5\u300d\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u6bd4\u8f03Ct\u6cd5\u3092\u653b\u7565\u3059\u308b\u305f\u3081\u306e\u7406\u8ad6\u3092\u304d\u3063\u3061\u308a\u304a\u3055\u3048\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2015-11-10T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-17T06:12:48+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de\",\"datePublished\":\"2015-11-10T00:00:00+00:00\",\"dateModified\":\"2025-04-17T06:12:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/\"},\"wordCount\":71,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-12.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/\",\"name\":\"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-12.jpg\",\"datePublished\":\"2015-11-10T00:00:00+00:00\",\"dateModified\":\"2025-04-17T06:12:48+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-12.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-12.jpg\",\"width\":1200,\"height\":630,\"caption\":\"qpcr-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic13\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/","og_locale":"ja_JP","og_type":"article","og_title":"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de","og_description":"\u691c\u91cf\u7dda\u3092\u3072\u304f\u305f\u3081\u306b\u5fc5\u8981\u306a\u3001\u6a19\u6e96\u30b5\u30f3\u30d7\u30eb\u306e\u8abf\u6574\u3068\u6e2c\u5b9a\u3002\u3053\u306e\u30b3\u30b9\u30c8\u3092\u7701\u3044\u3066\u5b9a\u91cf\u3067\u304d\u308b\u4fbf\u5229\u306a\u65b9\u6cd5\u304c\u300c\u6bd4\u8f03Ct\u6cd5\u300d\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u6bd4\u8f03Ct\u6cd5\u3092\u653b\u7565\u3059\u308b\u305f\u3081\u306e\u7406\u8ad6\u3092\u304d\u3063\u3061\u308a\u304a\u3055\u3048\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2015-11-10T00:00:00+00:00","article_modified_time":"2025-04-17T06:12:48+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de","datePublished":"2015-11-10T00:00:00+00:00","dateModified":"2025-04-17T06:12:48+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/"},"wordCount":71,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/","name":"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12.jpg","datePublished":"2015-11-10T00:00:00+00:00","dateModified":"2025-04-17T06:12:48+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12.jpg","width":1200,"height":630,"caption":"qpcr-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic13\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u691c\u91cf\u7dda\u3092\u3072\u304b\u305a\u306b\u5b9a\u91cf\u3059\u308b\u6bd4\u8f03Ct\u6cd5\u3068\u306f\uff1f\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c13\u56de"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":172,"position":0},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":172,"position":1},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24552,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qubit-dna-bid-ts-mbr-26001\/","url_meta":{"origin":172,"position":2},"title":"Qubit Fluorometer\u306b\u3064\u3044\u3066 \uff5eQubit Assay Kit\u306e\u6e2c\u5b9a\u7bc4\u56f2\uff5e","author":"LatB Staff","date":"2026\u5e741\u67089\u65e5","format":false,"excerpt":"Invitrogen\u2122 Qubit\u2122 Fluorometer \u306f\u3001\u5c02\u7528\u306e\u8a66\u85ac\u30ad\u30c3\u30c8\u3092\u7528\u3044\u308b\u3053\u3068\u3067DN\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/qubit-dna-bid-ts-mbr-26001_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":172,"position":3},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25121,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/elisa-nucleic-acid-purification-bid-ts-mbr-26017\/","url_meta":{"origin":172,"position":4},"title":"\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u30444PL\u306e\u57fa\u672c\uff1a4\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac","author":"LATB Staff","date":"2026\u5e745\u67087\u65e5","format":false,"excerpt":"ELISA\u306e\u691c\u91cf\u7dda\u3084\u7528\u91cf\u53cd\u5fdc\u66f2\u7dda\u3092\u4f5c\u6210\u3059\u308b\u3068\u304d\u306b\u30014\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u30ed\u30b8\u30b9\u30c6\u30a3\u30c3\u30af\uff084PL\uff09\u30e2\u30c7\u30eb\u3092\u4f7f\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/elisa-nucleic-acid-purification-bid-ts-mbr-26017_eyecatch-1-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20129,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25016\/","url_meta":{"origin":172,"position":5},"title":"\u3010\u7b2c2\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce","author":"LatB Staff","date":"2026\u5e744\u670828\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u969b\u306e\u64cd\u4f5c\u3067\u5f79\u7acb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u56de\u53ce\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u5c0f\u80de\u4f53\u30b5\u30a4\u30ba","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/251d14a615127ecd8e0dac1beeb32074.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-12.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/172","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=172"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/172\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2278"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=172"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=172"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=172"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}