{"id":17415,"date":"2024-06-21T11:51:04","date_gmt":"2024-06-21T02:51:04","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=17415"},"modified":"2025-04-15T16:05:14","modified_gmt":"2025-04-15T07:05:14","slug":"qpcr-gene-expression-gsd-ts-sd-24037","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/","title":{"rendered":"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5"},"content":{"rendered":"<p>\u65b0\u3057\u304f\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u969b\u3001\u307e\u305a\u521d\u3081\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306f\u8a66\u85ac\u3084\u88c5\u7f6e\u306e\u4f7f\u3044\u65b9\u3060\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u3053\u3046\u3044\u3063\u305f\u3082\u306e\u306e\u78ba\u8a8d\u3063\u3066\u610f\u5916\u3068\u5927\u5909\u3067\u3059\u3088\u306d\uff1f\u4eca\u56de\u306fSYBR Green\u8272\u7d20\u306e\u5b9f\u9a13\u7cfb\u3092\u6d3b\u7528\u3055\u308c\u3066\u3044\u308b\u65b9\u306b\u304a\u3059\u3059\u3081\u3057\u3066\u3044\u308bApplied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-reagents\/sybr-green-real-time-master-mixes\/powertrack-sybr-green-master-mix.html?CID=gsd_pcr_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_qpcr_gene_expression_gsd_ts_sd_24037_Social_LAB\" rel=\"noopener\" target=\"_blank\">PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR<\/a>\u306e\u4f7f\u7528\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3001\u8981\u70b9\u3092\u7d5e\u3063\u3066\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\uff01\u3053\u3061\u3089\u306e\u8a66\u85ac\u306b\u306f\u8272\u304c\u3064\u3044\u3066\u3044\u3066\u3001\u3069\u3053\u307e\u3067\u8a66\u85ac\u3092\u5206\u6ce8\u3057\u305f\u306e\u304b\u3082\u76ee\u8996\u3067\u7c21\u5358\u306b\u78ba\u8a8d\u53ef\u80fd\u3067\u3059\uff01<br \/>\n\u300c\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u306e\u306f\u3053\u308c\u304b\u3089\u3067\u64cd\u4f5c\u304c\u4e0d\u5b89\u300d\u3068\u3044\u3046\u65b9\u304b\u3089\u3001\u300c\u5e0c\u5c11\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u305f\u3081\u306b\u7d76\u5bfe\u306b\u64cd\u4f5c\u30df\u30b9\u3067\u304d\u306a\u3044\u300d\u3068\u3044\u3046\u73fe\u5834\u307e\u3067\u3001\u591a\u304f\u306e\u65b9\u3005\u306b\u5b89\u5fc3\u3057\u3066\u304a\u4f7f\u3044\u3044\u305f\u3060\u3051\u308b\u8a66\u85ac\u3067\u3059\u3002<\/p>\n<p>\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u3053\u308c\u304b\u3089SYBR Green\u8272\u7d20\u3092\u4f7f\u3063\u305f\u8a66\u85ac\u3067\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u5b9f\u9a13\u3092\u59cb\u3081\u3089\u308c\u308b\u65b9<br \/>\n\u30fb\u8a66\u85ac\u306e\u4f7f\u7528\u65b9\u6cd5\u306e\u8981\u70b9\u3092\u304b\u3044\u3064\u307e\u3093\u3067\u78ba\u8a8d\u3057\u305f\u3044\u65b9<br \/>\n\u30fb\u9577\u3044\u82f1\u8a9e\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u306b\u76ee\u3092\u901a\u3059\u6642\u9593\u304c\u306a\u3044\u65b9<\/p>\n<h2>\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a66\u85ac\u985e<\/h2>\n<p>PowerTrack SYBR Green Master Mix for qPCR<br \/>\n\uff08Yellow Sample Buffer\u3082\u540c\u68b1\u3055\u308c\u3066\u3044\u307e\u3059\uff09<br \/>\nForward primer<br \/>\nReverse primer<br \/>\ncDNA\u30b5\u30f3\u30d7\u30eb<br \/>\nNuclease-free water<\/p>\n<h2>\u5b9f\u9a13\u306e\u6d41\u308c<\/h2>\n<p>\u5b9f\u9a13\u306f<\/p>\n<ol>\n<li>\uff08\u30aa\u30d7\u30b7\u30e7\u30f3\uff09Yellow Sample Buffer\u3092cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306b\u6dfb\u52a0<\/li>\n<li>\u30d7\u30ec\u30df\u30c3\u30af\u30b9\u6eb6\u6db2\u306e\u8abf\u88fd<\/li>\n<li>\u30d7\u30ec\u30df\u30c3\u30af\u30b9\u6eb6\u6db2\u306e\u5206\u6ce8 + cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306e\u6dfb\u52a0<\/li>\n<li>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u3067\u6e2c\u5b9a<\/li>\n<\/ol>\n<p>\u3068\u3044\u3046\u6d41\u308c\u3067\u9032\u3081\u307e\u3059\u3002<\/p>\n<p>20 \u03bcL\/well\u3068\u3057\u3066\u8abf\u88fd\u3059\u308b\u3068\u304d\u3092\u4f8b\u3068\u3057\u3066\u3001\u5404\u30b9\u30c6\u30c3\u30d7\u3067\u306e\u64cd\u4f5c\u3092\u4e00\u3064\u305a\u3064\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n<h3>1. \uff08\u30aa\u30d7\u30b7\u30e7\u30f3\uff09Yellow Sample Buffer\u3092\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306b\u6dfb\u52a0<\/h3>\n<p>cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306b\u3042\u3089\u304b\u3058\u3081Yellow Sample Buffer\u3092\u6dfb\u52a0\u3057\u3066\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u3092\u9ec4\u8272\u306b\u3057\u307e\u3059\u3002PowerTrack SYBR Green Master Mix\u81ea\u4f53\u304c\u9752\u3044\u305f\u3081\u3001Yellow Sample Buffer\u3067\u9ec4\u8272\u304f\u3057\u305fcDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u3092\u52a0\u3048\u308b\u3053\u3068\u3067\u53cd\u5fdc\u6db2\u304c\u7dd1\u8272\u306b\u306a\u308a\u3001\u3069\u3053\u306e\u30d7\u30ec\u30df\u30c3\u30af\u30b9\u6eb6\u6db2\u307e\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u6dfb\u52a0\u3057\u305f\u304b\u3092\u8996\u899a\u7684\u306b\u8ffd\u3048\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<br \/>\n\u3082\u3061\u308d\u3093\u3001\u8a66\u85ac\u306b\u3064\u3051\u3089\u308c\u305f\u8272\u306f\u86cd\u5149\u306e\u691c\u51fa\u306b\u306f\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u305b\u3093\u3002<\/p>\n<p><div id=\"attachment_17416\" style=\"width: 444px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17416\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/6e93ca5416f7a2f1190971c95056a18c.jpg\" alt=\"\u305d\u308c\u305e\u308c\u9752\u3068\u9ec4\u8272\u306e\u8a66\u85ac\u3092\u2026\" width=\"434\" height=\"252\" class=\"size-full wp-image-17416\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/6e93ca5416f7a2f1190971c95056a18c.jpg 723w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/6e93ca5416f7a2f1190971c95056a18c-300x174.jpg 300w\" sizes=\"auto, (max-width: 434px) 100vw, 434px\" \/><p id=\"caption-attachment-17416\" class=\"wp-caption-text\">\u305d\u308c\u305e\u308c\u9752\u3068\u9ec4\u8272\u306e\u8a66\u85ac\u3092\u2026<\/p><\/div><br \/>\n<div id=\"attachment_17417\" style=\"width: 346px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-17417\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/d9cfee2c1cf793f85bbf7a2cca971577.jpg\" alt=\"\u6df7\u305c\u308b\u3068\u7dd1\u8272\u306b\uff01\" width=\"336\" height=\"453\" class=\"size-full wp-image-17417\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/d9cfee2c1cf793f85bbf7a2cca971577.jpg 534w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/d9cfee2c1cf793f85bbf7a2cca971577-223x300.jpg 223w\" sizes=\"auto, (max-width: 336px) 100vw, 336px\" \/><p id=\"caption-attachment-17417\" class=\"wp-caption-text\">\u6df7\u305c\u308b\u3068\u7dd1\u8272\u306b\uff01<\/p><\/div><\/p>\n<p>cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db22 \u03bcL\u306b\u5bfe\u3057\u3066Yellow Sample Buffer 0.5 \u03bcL\u306e\u5272\u5408\u3067\u6dfb\u52a0\u3057\u6df7\u5408\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u6e2c\u5b9a\u306b\u7528\u3044\u308bcDNA\u91cf\u306f1ng\u304b\u308910 ng\uff08gDNA\u306e\u3068\u304d\u306f10 ng\u304b\u3089100 ng\uff09\u304c\u6dfb\u52a0\u3055\u308c\u308b\u3088\u3046\u306b\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u203b\u6ce8\u610f<br \/>\nYellow Sample Buffer\u306f\u6e2c\u5b9a\u76f4\u524d\u306b\u52a0\u3048\u3066\u304f\u3060\u3055\u3044\u3002\u4e8b\u524d\u306b\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306bYellow Sample Buffer\u3092\u52a0\u3048\u3066\u9577\u671f\u9593\u4fdd\u5b58\u3059\u308b\u3053\u3068\u306fcDNA\u306e\u72b6\u614b\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3054\u3056\u3044\u307e\u3059\u3002<\/p>\n<p>\u25bcTips<br \/>\n\u30fbYellow Sample Buffer\u306e\u4f7f\u7528\u306f\u5fc5\u9808\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u64cd\u4f5c\u6570\u3092\u6e1b\u3089\u3057\u305f\u3044\u3001\u3068\u3044\u3046\u5834\u5408\u306b\u306f\u3053\u306e\u4f5c\u696d\u5de5\u7a0b\u306f\u30b9\u30ad\u30c3\u30d7\u3067\u304d\u307e\u3059\u3002<br \/>\n\u30fbcDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306f\u5fc5\u305a\u3057\u30822 \u03bcL\u3067\u3042\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30b5\u30f3\u30d7\u30eb\u6fc3\u5ea6\u306a\u3069\u306b\u3088\u3063\u3066\u6db2\u91cf\u3092\u8abf\u6574\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u305f\u3060\u3057\u3001\u3042\u307e\u308a\u591a\u304f\u306f\u5165\u308c\u904e\u304e\u306a\u3044\u3088\u3046\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306b\u306f\u9006\u8ee2\u5199\u53cd\u5fdc\u6642\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u306a\u3069\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u304c\u591a\u3044\u3068\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u53cd\u5fdc\u6db2\u306e\u7d44\u6210\u304c\u5909\u308f\u3063\u3066\u3057\u307e\u3044\u3001\u52b9\u7387\u826f\u304fPCR\u304c\u9032\u307e\u306a\u3044\u6050\u308c\u304c\u3042\u308a\u307e\u3059\u3002cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u306f\u53cd\u5fdc\u6db2\u5168\u91cf\u306e1\u5272\u7a0b\u5ea6\u3001\u591a\u304f\u3068\u30822\u5272\u7a0b\u5ea6\u304c\u4e00\u3064\u306e\u76ee\u5b89\u3067\u3059\u3002<br \/>\n\u30fbYellow Sample Buffer\u306f40\u00d7\u6fc3\u5ea6\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u306e\u3067\u3001cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u91cf\u306b\u95a2\u308f\u3089\u305a0.5 \u03bcL\u3092\u52a0\u3048\u3066\u3044\u305f\u3060\u3051\u308c\u3070\u300120 \u03bcL\/well\u306e\u5834\u5408\u3001\u7d42\u6fc3\u5ea6\u304c1\u00d7\u6fc3\u5ea6\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<h3>2. \u30d7\u30ec\u30df\u30c3\u30af\u30b9\u6eb6\u6db2\u306e\u8abf\u88fd<\/h3>\n<p>\u307e\u305a\u306fcDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2\u4ee5\u5916\u306b\u5fc5\u8981\u306a\u8a66\u85ac\u3092\u3042\u3089\u304b\u3058\u3081\u5168\u3066\u6df7\u305c\u3066\u3057\u307e\u3044\u307e\u3057\u3087\u3046\u3002\u53cd\u5fdc\u6db2\u91cf\u304c20 \u00b5L\u3068\u306a\u308b\u3088\u3046\u306b\u8abf\u88fd\u3059\u308b\u306b\u306f\u3001\u4e0b\u8868\u3092\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u305f\u3060\u3057\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u6eb6\u6db2\u3084cDNA\u30b5\u30f3\u30d7\u30eb\u306e\u6fc3\u5ea6\u306b\u3088\u3063\u3066\u306f\u3001\u305d\u308c\u305e\u308c\u306e\u6dfb\u52a0\u91cf\u304c\u5909\u308f\u308a\u307e\u3059\u3002\u305d\u306e\u5834\u5408\u306f\u3001\u6700\u5f8c\u306bNuclease-free water\u306e\u91cf\u3067\u5168\u4f53\u306e\u53cd\u5fdc\u6db2\u91cf\u304c20 \u00b5L\u3068\u306a\u308b\u3088\u3046\u306b\u8abf\u6574\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<table>\n<tbody style=\"border-bottom: none\">\n<tr bgcolor=\"white\">\n<td style=\"text-align: left\" width=\"20\"><b>Component<\/b><\/td>\n<td style=\"text-align: left\" width=\"60\"><b>Volume<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"40\">PowerTrack SYBR Green Master Mix (2X)<\/td>\n<td style=\"text-align: left\" width=\"20\">10\u03bcL<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"40\">forward and reverse primers<sup>\u203b<\/sup><\/td>\n<td style=\"text-align: left\" width=\"20\">1\u03bcL<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"40\">Nuclease-free water<\/td>\n<td style=\"text-align: left\" width=\"20\">6.5\u03bcL<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"40\">Total<\/td>\n<td style=\"text-align: left\" width=\"20\">17.5\u03bcL<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: right\" width=\"10\" colspan=\"2\">\u203b\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u63a8\u5968\u7d42\u6fc3\u5ea6\u306f300\uff5e800 nM\u3067\u3059\u3002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u25bcTips<br \/>\n\u30fbPowerTrack SYBR Green Master Mix for qPCR\u306f\u5ba4\u6e29\u30678\u6642\u9593\u5b89\u5b9a\u3067\u3059\u3002\u8a66\u85ac\u8abf\u88fd\u306e\u969b\u306b\u5ba4\u6e29\u306e\u307e\u307e\u64cd\u4f5c\u3044\u305f\u3060\u3051\u307e\u3059\u3002<br \/>\n\u30fb\u30de\u30b9\u30bf\u30fc\u30df\u30c3\u30af\u30b9\u8a66\u85ac\u306b\u306f\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u6eb6\u6db2\u5168\u4f53\u304c\u5747\u4e00\u306b\u306a\u308a\u306b\u304f\u3044\u305f\u3081\u3001\u5341\u5206\u306b\u6df7\u5408\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u53ef\u80fd\u3067\u3042\u308c\u3070\u30dc\u30eb\u30c6\u30c3\u30af\u30b9\u30df\u30ad\u30b5\u30fc\u306a\u3069\u3092\u7528\u3044\u3066\u3001\u6dfb\u52a0\u5f8c\u306b\u5341\u5206\u306b\u6df7\u5408\u3059\u308b\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\u3002<\/p>\n<h3>3. \u30d7\u30ec\u30df\u30c3\u30af\u30b9\u6eb6\u6db2\u306e\u5206\u6ce8 + cDNA\u30b5\u30f3\u30d7\u30eb\u306e\u6dfb\u52a0<\/h3>\n<p>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u3067\u306e\u6e2c\u5b9a\u306b\u4f7f\u7528\u3059\u308b96 well\u30d7\u30ec\u30fc\u30c8\u306a\u3069\u3092\u7528\u610f\u3057\u3001\u6e2c\u5b9a\u3059\u308b\u5404\u30a6\u30a7\u30eb\u306b2\u3067\u7528\u610f\u3057\u305f\u30d7\u30ec\u30df\u30c3\u30af\u30b9\u6eb6\u6db2\u3092\u5206\u6ce8\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u5404\u30a6\u30a7\u30eb\u306bcDNA\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6ce8\u3057\u307e\u3059\u3002\u305d\u308c\u305e\u308c\u306e\u5206\u6ce8\u91cf\u306f\u30011\u30842\u3067\u7528\u610f\u3057\u305f\u6db2\u91cf\u306b\u5408\u308f\u305b\u3066\u304f\u3060\u3055\u3044\u3002\u4f8b\u3048\u3070\u3001\u4eca\u56de\u306e\u4f8b\u3067\u3059\u3068\u30d7\u30ec\u30df\u30c3\u30af\u30b9\u6eb6\u6db2 17.5 \u03bcL + cDNA\u30b5\u30f3\u30d7\u30eb\u6eb6\u6db2 2.5 \u03bcL\u3067\u3059\u3002<\/p>\n<h3>4. \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u88c5\u7f6e\u3067\u6e2c\u5b9a<\/h3>\n<p>\u4ee5\u4e0b\u306e\u6761\u4ef6\u3067\u6e2c\u5b9a\u3092\u884c\u3044\u307e\u3059\u3002<br \/>\n\u901a\u5e38\u306fFast cycling\u306e\u6761\u4ef6\u3067\u6e2c\u5b9a\u3057\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u304cgDNA\u306e\u5834\u5408\u3084\u5897\u5e45\u7523\u7269\u9577\u304c\u9577\u3044\u5834\u5408\u306b\u306fStandard cycling\u306e\u6761\u4ef6\u3067\u6e2c\u5b9a\u3059\u308b\u306e\u304c\u304a\u3059\u3059\u3081\u3067\u3059\u3002<\/p>\n<table>\n<caption><b>Fast cycling<\/b><\/caption>\n<tbody>\n<tr bgcolor=\"white\">\n<td style=\"text-align: Center\" width=\"20\"><b>Step<\/b><\/td>\n<td style=\"text-align: Center\" width=\"50\"><b>Temperature<\/b><\/td>\n<td style=\"text-align: Center\" width=\"50\"><b>Duration<\/b><\/td>\n<td style=\"text-align: Center\" width=\"50\"><b>Cycles<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"10\">Enzyme activation<\/td>\n<td style=\"text-align: Center\" width=\"10\">95\u2103<\/td>\n<td style=\"text-align: Center\" width=\"10\">2 minutes<\/td>\n<td style=\"text-align: Center\" width=\"10\">1<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"10\">Denature<\/td>\n<td style=\"text-align: Center\" width=\"10\">95\u2103<\/td>\n<td style=\"text-align: Center\" width=\"10\">5 seconds<\/td>\n<td style=\"text-align: Center\" width=\"10\" rowspan=\"2\">40<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"10\">Annealing\/extend<\/td>\n<td style=\"text-align: Center\" width=\"10\">60\u2103<\/td>\n<td style=\"text-align: Center\" width=\"10\">30 seconds<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"40\" colspan=\"4\">Melt Curve<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<table>\n<caption><b>Standard cycling<\/b><\/caption>\n<tbody>\n<tr bgcolor=\"white\">\n<td style=\"text-align: Center\" width=\"20\"><b>Step<\/b><\/td>\n<td style=\"text-align: Center\" width=\"50\"><b>Temperature<\/b><\/td>\n<td style=\"text-align: Center\" width=\"50\"><b>Duration<\/b><\/td>\n<td style=\"text-align: Center\" width=\"50\"><b>Cycles<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"10\">Enzyme activation<\/td>\n<td style=\"text-align: Center\" width=\"10\">95\u2103<\/td>\n<td style=\"text-align: Center\" width=\"10\">2 minutes<\/td>\n<td style=\"text-align: Center\" width=\"10\">1<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"10\">Denature<\/td>\n<td style=\"text-align: Center\" width=\"10\">95\u2103<\/td>\n<td style=\"text-align: Center\" width=\"10\">15 seconds<\/td>\n<td style=\"text-align: Center\" width=\"10\" rowspan=\"2\">40<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"10\">Annealing\/extend<\/td>\n<td style=\"text-align: Center\" width=\"10\">60\u2103<\/td>\n<td style=\"text-align: Center\" width=\"10\">60 seconds<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: Center\" width=\"40\" colspan=\"4\">Melt Curve<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u25bcTips<br \/>\n\u5f53\u793e\u306e\u88c5\u7f6e\u306e\u5834\u5408\u3001\u30c7\u30d5\u30a9\u30eb\u30c8\u3067\u8868\u793a\u3055\u308c\u308bMelt Curve\u306e\u6761\u4ef6\u304c\u305d\u308c\u305e\u308c\u306e\u88c5\u7f6e\u306b\u5408\u308f\u305b\u305f\u6761\u4ef6\u3068\u306a\u3063\u3066\u3044\u308b\u305f\u3081\u3001\u57fa\u672c\u7684\u306b\u306f\u30c7\u30d5\u30a9\u30eb\u30c8\u6761\u4ef6\u306e\u307e\u307e\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u6e2c\u5b9a\u304c\u59cb\u307e\u3063\u305f\u3089\u3042\u3068\u306f\u7d50\u679c\u304c\u51fa\u308b\u306e\u3092\u5f85\u3064\u3060\u3051\u3067\u3059\uff01<br \/>\nPowerTrack SYBR\u2122 Green Master Mix for qPCR\u306ePCR\u306f\u304a\u3088\u305d40\u5206\u7a0b\u5ea6\u3067\u7d42\u308f\u308a\u307e\u3059\u3002Melt Curve\u3082\u88c5\u7f6e\u306b\u3088\u3063\u3066\u306f5\u5206\u7a0b\u5ea6\u3067\u6e2c\u5b9a\u3067\u304d\u307e\u3059\u306e\u3067\u30011\u30e9\u30f3\u306e\u6e2c\u5b9a\u306b50\u5206\u3082\u304b\u304b\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>\u305c\u3072\u7686\u3055\u307e\u3082\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\uff01<br \/>\n\u4eca\u56de\u306e\u8a18\u4e8b\u4f5c\u6210\u306b\u3042\u305f\u308a\u307e\u3057\u3066\u3001\u300c<a href=\"https:\/\/www.thermofisher.com\/document-connect\/document-connect.html?url=https:\/\/assets.thermofisher.com\/TFS-Assets%2FLSG%2Fmanuals%2FMAN0018825_PowerTrackSYBRGreenMasterMix_UG.pdf?CID=gsd_pcr_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_qpcr_gene_expression_gsd_ts_sd_24037_Social_LAB\" rel=\"noopener\" target=\"_blank\">User Guide: PowerTrack SYBR Green Master Mix<\/a>\u300d\u3092\u53c2\u7167\u3057\u3066\u3044\u307e\u3059\u3002\u3088\u308a\u8a73\u7d30\u306a\u5185\u5bb9\u3092\u78ba\u8a8d\u3057\u305f\u3044\u65b9\u306f\u3053\u3061\u3089\u3082\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u25bcTips<br \/>\n\u3053\u3053\u307e\u306720 \u03bcL\/well\u3067\u306e\u53cd\u5fdc\u6db2\u91cf\u3067\u7d39\u4ecb\u3057\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u3053\u306e\u6db2\u91cf\u3067\u306e\u8abf\u88fd\u306f\u5fc5\u9808\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u304a\u624b\u5143\u306e\u72b6\u6cc1\u306b\u5408\u308f\u305b\u3066\u3001\u540c\u3058\u6bd4\u7387\u3067\u6db2\u91cf\u3092\u5897\u3084\u3057\u305f\u308a\u6e1b\u3089\u3057\u305f\u308a\u3057\u3066\u8abf\u88fd\u3044\u305f\u3060\u304f\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u305d\u306e\u4ed6\u3001\u8a66\u85ac\u306e\u4f7f\u7528\u65b9\u6cd5\u306a\u3069\u3067\u304a\u56f0\u308a\u306e\u3053\u3068\u304c\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u307e\u3067\u304a\u6c17\u8efd\u306b\u3054\u9023\u7d61\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>TEL: 0120-477-392 \uff08\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c0\u30a4\u30ec\u30af\u30c8\u756a\u53f7\uff1a1\u756a\uff09<br \/>\nEmail: <a href=\"mailto:jptech@thermofisher.com\">jptech@thermofisher.com<\/a><\/p>\n<h3>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_qpcr_gene_expression_gsd_ts_sd_24037_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h3>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30b7\u30b9\u30c6\u30e0 \u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_qpcr_gene_expression_gsd_ts_sd_24037_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>\u95a2\u9023\u30d6\u30ed\u30b0<br \/>\nApplied Biosystems\u2122 TaqMan\u2122 Assay \u7528\u306e\u30de\u30b9\u30bf\u30fc\u30df\u30c3\u30af\u30b9\u8a66\u85ac\u306e\u4f7f\u3044\u65b9<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/taqman_qpcr_gsd_ts_5\/?CID=gsd_pcr_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_qpcr_gene_expression_gsd_ts_sd_24037_Social_LAB\" rel=\"noopener\" target=\"_blank\">TaqMan Fast Advanced Master Mix\u306e\u4f7f\u7528\u65b9\u6cd5<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u65b0\u3057\u304f\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u969b\u3001\u307e\u305a\u521d\u3081\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306f\u8a66\u85ac\u3084\u88c5\u7f6e\u306e\u4f7f\u3044\u65b9\u3060\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u3053\u3046\u3044\u3063\u305f\u3082\u306e\u306e\u78ba\u8a8d\u3063\u3066\u610f\u5916\u3068\u5927\u5909\u3067\u3059\u3088\u306d\uff1f\u4eca\u56de\u306fSYBR Green\u8272\u7d20\u306e\u5b9f\u9a13\u7cfb\u3092\u6d3b\u7528\u3055\u308c\u3066\u3044\u308b\u65b9\u306b\u304a\u3059\u3059\u3081\u3057\u3066\u3044\u308bApplied Bio<\/p>\n","protected":false},"author":975,"featured_media":17418,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7,189],"division":[],"class_list":["post-17415","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","tag-gene-expression","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5\" \/>\n<meta property=\"og:description\" content=\"\u65b0\u3057\u304f\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u969b\u3001\u307e\u305a\u521d\u3081\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306f\u8a66\u85ac\u3084\u88c5\u7f6e\u306e\u4f7f\u3044\u65b9\u3060\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u3053\u3046\u3044\u3063\u305f\u3082\u306e\u306e\u78ba\u8a8d\u3063\u3066\u610f\u5916\u3068\u5927\u5909\u3067\u3059\u3088\u306d\uff1f\u4eca\u56de\u306fSYBR Green\u8272\u7d20\u306e\u5b9f\u9a13\u7cfb\u3092\u6d3b\u7528\u3055\u308c\u3066\u3044\u308b\u65b9\u306b\u304a\u3059\u3059\u3081\u3057\u3066\u3044\u308bApplied Bio\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-06-21T02:51:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-15T07:05:14+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"10\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5\",\"datePublished\":\"2024-06-21T02:51:04+00:00\",\"dateModified\":\"2025-04-15T07:05:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/\"},\"wordCount\":234,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/06\\\/e1ea879c0f4087e60a100029dc1154a7.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\",\"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/\",\"name\":\"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/06\\\/e1ea879c0f4087e60a100029dc1154a7.jpg\",\"datePublished\":\"2024-06-21T02:51:04+00:00\",\"dateModified\":\"2025-04-15T07:05:14+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/06\\\/e1ea879c0f4087e60a100029dc1154a7.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/06\\\/e1ea879c0f4087e60a100029dc1154a7.jpg\",\"width\":1000,\"height\":667},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-gene-expression-gsd-ts-sd-24037\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/","og_locale":"ja_JP","og_type":"article","og_title":"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5","og_description":"\u65b0\u3057\u304f\u5b9f\u9a13\u3092\u59cb\u3081\u308b\u969b\u3001\u307e\u305a\u521d\u3081\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u306f\u8a66\u85ac\u3084\u88c5\u7f6e\u306e\u4f7f\u3044\u65b9\u3060\u3068\u601d\u3044\u307e\u3059\u304c\u3001\u3053\u3046\u3044\u3063\u305f\u3082\u306e\u306e\u78ba\u8a8d\u3063\u3066\u610f\u5916\u3068\u5927\u5909\u3067\u3059\u3088\u306d\uff1f\u4eca\u56de\u306fSYBR Green\u8272\u7d20\u306e\u5b9f\u9a13\u7cfb\u3092\u6d3b\u7528\u3055\u308c\u3066\u3044\u308b\u65b9\u306b\u304a\u3059\u3059\u3081\u3057\u3066\u3044\u308bApplied Bio","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-06-21T02:51:04+00:00","article_modified_time":"2025-04-15T07:05:14+00:00","og_image":[{"width":1000,"height":667,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"10\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5","datePublished":"2024-06-21T02:51:04+00:00","dateModified":"2025-04-15T07:05:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/"},"wordCount":234,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/","name":"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg","datePublished":"2024-06-21T02:51:04+00:00","dateModified":"2025-04-15T07:05:14+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg","width":1000,"height":667},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-gene-expression-gsd-ts-sd-24037\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"PowerTrack\u2122 SYBR\u2122 Green Master Mix for qPCR\u306e\u4f7f\u7528\u65b9\u6cd5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"},{"value":189,"label":"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg",760,507,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]},{"term_id":189,"name":"\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790","slug":"gene-expression","term_group":0,"term_taxonomy_id":189,"taxonomy":"post_tag","description":"","parent":0,"count":12,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/06\/e1ea879c0f4087e60a100029dc1154a7.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/17415","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=17415"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/17415\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/17418"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=17415"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=17415"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=17415"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=17415"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}