{"id":17800,"date":"2024-08-20T17:02:12","date_gmt":"2024-08-20T08:02:12","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=17800"},"modified":"2025-10-03T11:44:39","modified_gmt":"2025-10-03T02:44:39","slug":"nanodrop-maintenance-6-bid-ts-mbr-24053","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/","title":{"rendered":"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e"},"content":{"rendered":"\n<ol class=\"wp-block-list\">\n<li>\u4eca\u56de\u306f\u524d\u56de\u306b\u5f15\u304d\u7d9a\u304d\u53f0\u5ea7\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u3064\u3044\u3066\u3054\u6848\u5185\u3057\u307e\u3059\u3002\u524d\u56de\u306f\u65e5\u3005\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u4e00\u74b0\u3068\u3057\u3066\u5b9f\u65bd\u53ef\u80fd\u306a\u7c21\u6613\u7684\u306a\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306b\u3064\u3044\u3066\u3054\u6848\u5185\u3057\u307e\u3057\u305f\u3002\u4eca\u56de\u306f\u3001\u53f0\u5ea7\u306b\u8efd\u5fae\u306a\u6c5a\u308c\u304c\u3042\u308b\u969b\u306e\u6700\u9069\u306a\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u6848\u5185\u3057\u307e\u3059\u3002\u7279\u306b\u53f0\u5ea7\u3078\u306e\u56fa\u7740\u306e\u53ef\u80fd\u6027\u304c\u3042\u308b\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u3084\u3001\u63ee\u767a\u6027\u304c\u9ad8\u3044\u6eb6\u5a92\u30fb\u754c\u9762\u6d3b\u6027\u5264\u3092\u542b\u3080\u3088\u3046\u306a\u6eb6\u5a92\u306b\u5e0c\u91c8\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u6e2c\u5b9a\u306e\u969b\u306b\u6709\u52b9\u306a\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3067\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br>\u30fb\u5438\u5149\u5ea6\u6e2c\u5b9a\u3092\u5b9f\u65bd\u3055\u308c\u3066\u3044\u308b\u65b9<br>\u30fb\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u3092\u3054\u5229\u7528\u30fb\u3054\u691c\u8a0e\u306e\u65b9<br>Web\u30b5\u30a4\u30c8\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/uv-vis-spectrophotometry\/instruments\/nanodrop\/resources.html?CID=bid_pca_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nanodrop_maintenance_6_bid_ts_mbr_24053_Social_LAB\" target=\"_blank\" rel=\"noopener\">thermofisher.com\/jp-nanodrop-setup<\/a>\uff09\u306b\u3042\u308b\u52d5\u753b\u8cc7\u6599\u3082\u4f75\u305b\u3066\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u8efd\u5fae\u306a\u53f0\u5ea7\u6c5a\u308c\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u65b9\u6cd5\">\u8efd\u5fae\u306a\u53f0\u5ea7\u6c5a\u308c\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u65b9\u6cd5<\/h2>\n\n\n\n<p>Thermo Scientific\u2122 NanoDrop\u2122\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u3092\u9577\u5e74\u306b\u308f\u305f\u3063\u3066\u3054\u5229\u7528\u3044\u305f\u3060\u3044\u3066\u3044\u308b\u5834\u5408\u3001\u65e5\u3005\u306e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u884c\u3063\u3066\u3082\u308f\u305a\u304b\u306b\u6b8b\u7559\u3057\u305f\u6c5a\u308c\u304c\u84c4\u7a4d\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u6e2c\u5b9a\u7d50\u679c\u304c\u5b89\u5b9a\u3057\u306a\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u7d4c\u5e74\u7684\u306a\u84c4\u7a4d\u6c5a\u308c\u306b\u95a2\u3057\u3066\u306f\u3001\u84b8\u7559\u6c34\u3092\u7528\u3044\u3066\u306e\u7c21\u6613\u7684\u306a\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u65b9\u6cd5\u3067\u306f\u89e3\u6c7a\u3067\u304d\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u3092\u6e2c\u5b9a\u3059\u308b\u5834\u5408\u3082\u3001\u65e5\u3005\u306e\u7c21\u6613\u7684\u306a\u53f0\u5ea7\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u6cd5\u3067\u306f\u6e2c\u5b9a\u306b\u7528\u3044\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u306e\u62ed\u304d\u6b8b\u3057\u306a\u3069\u3067\u5341\u5206\u306b\u53f0\u5ea7\u306e\u74b0\u5883\u3092\u7dad\u6301\u3067\u304d\u305a\u6e2c\u5b9a\u304c\u5b89\u5b9a\u3057\u306a\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<br>\u3053\u306e\u3088\u3046\u306a\u7d4c\u5e74\u7684\u306a\u84c4\u7a4d\u6c5a\u308c\u3084\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u539f\u56e0\u306e\u53f0\u5ea7\u6c5a\u308c\u306b\u3064\u3044\u3066\u306f\u7279\u5225\u306a\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u6cd5\u3068\u3057\u30660.5 N\u306e\u5869\u9178\u306b\u3088\u308b\u53f0\u5ea7\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3092\u63a8\u5968\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u5b9f\u65bd\u306e\u65b9\u6cd5\u306f\u524d\u56de\u306e\u7c21\u6613\u7684\u306a\u53f0\u5ea7\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306e\u65b9\u6cd5\u3068\u540c\u3058\u64cd\u4f5c\u3067\u3059\u304c\u3001\u84b8\u7559\u6c34\u306e\u4ee3\u308f\u308a\u306b\u5869\u9178\u6eb6\u6db2\u3092\u7528\u3044\u307e\u3059\u3002<br>\u307e\u305a\u306f0.5 N\u306e\u5869\u9178\u3092\u8abf\u88fd\u3057\u307e\u3059\u3002<br>\u4ee5\u964d\u306e\u64cd\u4f5c\u306f\u4ee5\u4e0b\u306e\u3068\u304a\u308a\u3067\u3059\uff08\u56f31\u53c2\u7167\uff09\u3002<br>\u2460 \uff1a \u30a2\u30fc\u30e0\u3092\u4e0a\u3052\u307e\u3059<br>\u2461 \uff1a \u4e0b\u90e8\u53f0\u5ea7\u3092\u304d\u308c\u3044\u306a\u30e9\u30dc\u30da\u30fc\u30d1\u30fc\u3067\u62ed\u304d\u307e\u3059<br>\u2462 \uff1a \u4e0a\u90e8\u53f0\u5ea7\u3082\u304d\u308c\u3044\u306a\u30e9\u30dc\u30da\u30fc\u30d1\u30fc\u3067\u62ed\u304d\u307e\u3059<br>\u2003\u2003\u2002\u2460~\u2462\u306e\u64cd\u4f5c\u3067\u53f0\u5ea7\u306e\u8efd\u5fae\u306a\u6c5a\u308c\u3092\u307e\u305a\u306f\u9664\u53bb\u3057\u307e\u3059<\/p>\n\n\n\n<p>\u2463 \uff1a \u4e0b\u90e8\u53f0\u5ea7\u306b0.5 N\u5869\u9178\u30922\uff5e3 \u00b5L\u4e57\u305b\u307e\u3059<br>\u2464 \uff1a \u30a2\u30fc\u30e0\u3092\u4e0b\u308d\u3057\u30662\uff5e3\u5206\u9759\u7f6e\u3057\u307e\u3059<br>\u2465 \uff1a \u4e0b\u90e8\u53f0\u5ea7\u3092\u304d\u308c\u3044\u306a\u30e9\u30dc\u30da\u30fc\u30d1\u30fc\u3067\u62ed\u304d\u307e\u3059<br>\u2466 \uff1a \u4e0a\u90e8\u53f0\u5ea7\u3092\u304d\u308c\u3044\u306a\u30e9\u30dc\u30da\u30fc\u30d1\u30fc\u3067\u62ed\u304d\u307e\u3059<br>\u2003\u2003\u2002\u2463~\u2466\u306e\u64cd\u4f5c\u3067\u53f0\u5ea7\u306b\u56fa\u7740\u3057\u305f\u7d4c\u5e74\u7684\u306a\u6c5a\u308c\u3084\u30bf\u30f3\u30d1\u30af\u8cea\u6c5a\u308c\u3092\u843d\u3068\u3057\u3084\u3059\u304f\u3057\u62ed\u304d\u53d6\u308a\u307e\u3059<\/p>\n\n\n\n<p>\u2467 \uff1a \u4e0b\u90e8\u53f0\u5ea7\u306b\u84b8\u7559\u6c34\u30922\uff5e3 \u00b5L\u4e57\u305b\u307e\u3059<br>\u2468 \uff1a \u30a2\u30fc\u30e0\u3092\u4e0b\u308d\u3057\u30662\uff5e3\u5206\u9759\u7f6e\u3057\u307e\u3059<br>\u2469 \uff1a \u4e0b\u90e8\u53f0\u5ea7\u3092\u304d\u308c\u3044\u306a\u30e9\u30dc\u30da\u30fc\u30d1\u30fc\u3067\u62ed\u304d\u307e\u3059<br>\u246a \uff1a \u4e0a\u90e8\u53f0\u5ea7\u3092\u304d\u308c\u3044\u306a\u30e9\u30dc\u30da\u30fc\u30d1\u30fc\u3067\u62ed\u304d\u307e\u3059<br>\u2003\u2003\u2002\u2467~\u246a\u306e\u64cd\u4f5c\u3067\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u7528\u3044\u305f\u5869\u9178\u6210\u5206\u3092\u9664\u53bb\u3057\u307e\u3059<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-17803\"><img loading=\"lazy\" decoding=\"async\" width=\"1835\" height=\"2560\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/cec251e9d449a803c1d592085cd04823-scaled.jpg\" alt=\"\u56f31. 0.5 N\u5869\u9178\u3092\u7528\u3044\u305f\u53f0\u5ea7\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\" class=\"wp-image-17803\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/cec251e9d449a803c1d592085cd04823-scaled.jpg 1835w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/cec251e9d449a803c1d592085cd04823-215x300.jpg 215w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/cec251e9d449a803c1d592085cd04823-734x1024.jpg 734w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/cec251e9d449a803c1d592085cd04823-768x1071.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/cec251e9d449a803c1d592085cd04823-1101x1536.jpg 1101w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/cec251e9d449a803c1d592085cd04823-1468x2048.jpg 1468w\" sizes=\"auto, (max-width: 1835px) 100vw, 1835px\" \/><figcaption class=\"wp-element-caption\">\u56f31. 0.5 N\u5869\u9178\u3092\u7528\u3044\u305f\u53f0\u5ea7\u30af\u30ea\u30fc\u30cb\u30f3\u30b0<\/figcaption><\/figure>\n\n\n\n<p>\u4ee5\u4e0a\u304c0.5 N\u306e\u5869\u9178\u3092\u7528\u3044\u305f\u53f0\u5ea7\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3067\u3059\u3002\u4e00\u822c\u7684\u306a\u7d4c\u5e74\u6c5a\u308c\u3084\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u306e\u8efd\u5fae\u306a\u6c5a\u308c\u306b\u3064\u3044\u3066\u306f\u4e0a\u8a18\u65b9\u6cd5\u3067\u5341\u5206\u306a\u6539\u5584\u304c\u898b\u8fbc\u307e\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u307e\u305f0.5 N\u306e\u5869\u9178\u306e\u4ee3\u308f\u308a\u306b0.5%\u6b21\u4e9c\u5869\u7d20\u9178\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u53f0\u5ea7\u306e\u6c5a\u67d3\u9664\u53bb\u3082\u5b9f\u65bd\u53ef\u80fd\u3067\u3059\u3002\u81e8\u5e8a\u691c\u4f53\u306a\u3069\u306e\u611f\u67d3\u6027\u691c\u4f53\u306e\u6e2c\u5b9a\u5f8c\u306f\u5fc5\u8981\u306b\u5fdc\u3058\u3066\u6b21\u4e9c\u5869\u7d20\u9178\u306b\u3088\u308b\u9664\u67d3\u64cd\u4f5c\u3092\u540c\u69d8\u306e\u64cd\u4f5c\u306b\u3066\u5b9f\u65bd\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53f0\u5ea7\u6c5a\u308c\u304c\u5438\u5149\u5ea6\u6e2c\u5b9a\u306b\u5f71\u97ff\u3059\u308b\u7406\u7531\">\u53f0\u5ea7\u6c5a\u308c\u304c\u5438\u5149\u5ea6\u6e2c\u5b9a\u306b\u5f71\u97ff\u3059\u308b\u7406\u7531<\/h2>\n\n\n\n<p>\u305d\u3082\u305d\u3082\u53f0\u5ea7\u306e\u6c5a\u308c\u304c\u306a\u305c\u5438\u5149\u5ea6\u306e\u6e2c\u5b9a\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n\n\n\n<p>NanoDrop\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u306f\u4e0b\u90e8\u53f0\u5ea7\u306b\u30b5\u30f3\u30d7\u30eb\u3092\u6570\u00b5L\u4e57\u305b\u3001\u30a2\u30fc\u30e0\u3092\u4e0b\u308d\u3059\u3053\u3068\u3067\u4e0a\u90e8\u306e\u53f0\u5ea7\u306e\u9593\u3067\u300c\u6db2\u67f1\u300d\u3092\u5f62\u6210\u3057\u307e\u3059\u3002\u3053\u306e\u5f62\u6210\u3055\u308c\u305f\u300c\u6db2\u67f1\u300d\u3092\u901a\u904e\u3057\u305f\u900f\u904e\u5149\u304b\u3089\u5438\u5149\u5ea6\u3092\u7b97\u51fa\u3057\u307e\u3059\u3002<br>\u53f0\u5ea7\u306b\u6c5a\u308c\u304c\u306a\u3044\u72b6\u614b\u3067\u3042\u308c\u3070\u3001\u53f0\u5ea7\u4e0a\u306b\u4e57\u305b\u3089\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u306f\u8868\u9762\u5f35\u529b\u306b\u3088\u308a\u5f35\u308a\u306e\u3042\u308b\u300c\u6db2\u6ef4\u300d\u3092\u5f62\u6210\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08\u56f32\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-17805\"><img loading=\"lazy\" decoding=\"async\" width=\"1162\" height=\"434\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/a9d1628e1aaa13e6407ead09185af7c9.jpg\" alt=\"\u56f32. \u6b63\u5e38\u306a\u53f0\u5ea7\u74b0\u5883\u306b\u3088\u308b\u6db2\u67f1\u5f62\u6210\u3068\u6db2\u6ef4\u5f62\u6210\" class=\"wp-image-17805\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/a9d1628e1aaa13e6407ead09185af7c9.jpg 1162w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/a9d1628e1aaa13e6407ead09185af7c9-300x112.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/a9d1628e1aaa13e6407ead09185af7c9-1024x382.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/a9d1628e1aaa13e6407ead09185af7c9-768x287.jpg 768w\" sizes=\"auto, (max-width: 1162px) 100vw, 1162px\" \/><figcaption class=\"wp-element-caption\">\u56f32. \u6b63\u5e38\u306a\u53f0\u5ea7\u74b0\u5883\u306b\u3088\u308b\u6db2\u67f1\u5f62\u6210\u3068\u6db2\u6ef4\u5f62\u6210<\/figcaption><\/figure>\n\n\n\n<p>NanoDrop\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u306e\u5438\u5149\u5ea6\u6e2c\u5b9a\u539f\u7406\u306b\u3064\u3044\u3066\u306f\u4ee5\u4e0b\u30ea\u30f3\u30af\u306e\u30d6\u30ed\u30b0\u3082\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<br><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-sample-ts\/?CID=bid_pca_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nanodrop_maintenance_6_bid_ts_mbr_24053_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-sample-ts\/<\/a><\/p>\n\n\n\n<p>\u3082\u3057\u53f0\u5ea7\u306b\u6c5a\u308c\u304c\u3042\u308b\u5834\u5408\u3001\u8868\u9762\u5f35\u529b\u304c\u4f5c\u7528\u305b\u305a\u5341\u5206\u306a\u300c\u6db2\u6ef4\u300d\u3092\u5f62\u6210\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u305b\u3093\u3002\u7d50\u679c\u7684\u306b\u30a2\u30fc\u30e0\u3092\u4e0b\u3052\u305f\u969b\u306b\u4e0a\u4e0b\u306e\u53f0\u5ea7\u9593\u3067\u5341\u5206\u306a\u300c\u6db2\u67f1\u300d\u3092\u5f62\u6210\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u304f\u306a\u308a\u3001\u6b63\u78ba\u306a\u5438\u5149\u5ea6\u306e\u6e2c\u5b9a\u304c\u3067\u304d\u306a\u304f\u306a\u308a\u307e\u3059\uff08\u56f33\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-17806\"><img loading=\"lazy\" decoding=\"async\" width=\"1137\" height=\"473\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/ff574e9952798fa96f34ce9bac66f24d.jpg\" alt=\"\u56f33. \u53f0\u5ea7\u304c\u6c5a\u308c\u3066\u3044\u308b\u5834\u5408\u306e\u6db2\u67f1\u5f62\u6210\" class=\"wp-image-17806\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/ff574e9952798fa96f34ce9bac66f24d.jpg 1137w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/ff574e9952798fa96f34ce9bac66f24d-300x125.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/ff574e9952798fa96f34ce9bac66f24d-1024x426.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/08\/ff574e9952798fa96f34ce9bac66f24d-768x319.jpg 768w\" sizes=\"auto, (max-width: 1137px) 100vw, 1137px\" \/><figcaption class=\"wp-element-caption\">\u56f33. \u53f0\u5ea7\u304c\u6c5a\u308c\u3066\u3044\u308b\u5834\u5408\u306e\u6db2\u67f1\u5f62\u6210<\/figcaption><\/figure>\n\n\n\n<p>\u53f0\u5ea7\u306e\u6c5a\u308c\u306b\u3064\u3044\u3066\u306f\u7a0b\u5ea6\u3084\u6e2c\u5b9a\u5bfe\u8c61\u3068\u306a\u308b\u30b5\u30f3\u30d7\u30eb\u7279\u6027\u306b\u3082\u3088\u308a\u307e\u3059\u304c\u3001\u6db2\u67f1\u304c\u5f62\u6210\u3055\u308c\u306b\u304f\u3044\u983b\u5ea6\u304c\u4e0a\u304c\u308a\u3001\u7d50\u679c\u3068\u3057\u3066\u3001\u540c\u3058\u30b5\u30f3\u30d7\u30eb\u3092\u6e2c\u5b9a\u3057\u3066\u3044\u308b\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u5438\u5149\u5ea6\u304c\u5b89\u5b9a\u3057\u306a\u3044\u306a\u3069\u306e\u539f\u56e0\u306b\u306a\u308a\u307e\u3059\u3002<br>\u3064\u307e\u308a\u53f0\u5ea7\u306e\u72b6\u614b\u304c\u304d\u308c\u3044\u3067\u3001\u5341\u5206\u306a\u8868\u9762\u5f35\u529b\u3092\u6709\u3057\u3066\u3044\u308b\u72b6\u614b\u3067\u3042\u308c\u3070\u3001\u5b89\u5b9a\u3057\u305f\u5438\u5149\u5ea6\u6e2c\u5b9a\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p>\u4eca\u56de\u306f\u53f0\u5ea7\u306e\u8efd\u5fae\u306a\u6c5a\u308c\u306b\u5bfe\u3059\u308b\u53f0\u5ea7\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002<br>\u30bf\u30f3\u30d1\u30af\u8cea\u30b5\u30f3\u30d7\u30eb\u306e\u6e2c\u5b9a\u5f8c\u3001\u7279\u306b\u56fa\u7740\u304c\u8d77\u3053\u308a\u3084\u3059\u3044\u30d6\u30e9\u30c3\u30c9\u30d5\u30a9\u30fc\u30c9\u30bf\u30f3\u30d1\u30af\u8cea\u30a2\u30c3\u30bb\u30a4\u306e\u5438\u5149\u5ea6\u6e2c\u5b9a\u3092\u5b9f\u65bd\u3057\u305f\u969b\u3001\u4eca\u56de\u3054\u6848\u5185\u3057\u305f0.5 N\u5869\u9178\u3067\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u304c\u6709\u52b9\u306a\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u65b9\u6cd5\u3068\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u6c34\u3084TE\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u6eb6\u89e3\u3057\u305f\u6838\u9178\u30b5\u30f3\u30d7\u30eb\u306e\u6e2c\u5b9a\u304c\u4e2d\u5fc3\u306e\u5834\u5408\u3067\u3082\u3001\u5b9a\u671f\u7684\u306b\u5869\u9178\u3092\u7528\u3044\u305f\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3092\u5b9f\u65bd\u3044\u305f\u3060\u304f\u3053\u3068\u3067\u7d4c\u5e74\u7684\u306a\u84c4\u7a4d\u6c5a\u308c\u3092\u9664\u53bb\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u3088\u308a\u5b89\u5b9a\u3057\u305f\u5438\u5149\u5ea6\u6e2c\u5b9a\u3092\u53ef\u80fd\u3068\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u4eca\u56de\u3054\u6848\u5185\u3057\u305f\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3082NanoDrop\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u5171\u901a\u3067\u5b9f\u65bd\u3044\u305f\u3060\u3051\u307e\u3059\u3002\u6b21\u56de\u306f\u3088\u308a\u5f37\u56fa\u306a\u56fa\u7740\u6c5a\u308c\u304c\u3042\u308b\u53f0\u5ea7\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u3053\u306e\u30b7\u30ea\u30fc\u30ba\u3067\u306fNanoDrop\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u306b\u3088\u308b\u5438\u5149\u5ea6\u6e2c\u5b9a\u306b\u95a2\u308f\u308b\u60c5\u5831\u3084Tips\u3092\u3054\u6848\u5185\u3057\u3066\u3044\u304f\u4e88\u5b9a\u3067\u3059\u3002\u4ee5\u4e0b\u30ea\u30f3\u30af\u3088\u308a\u300cNanoDrop\u300d\u306b\u95a2\u9023\u3059\u308b\u30d6\u30ed\u30b0\u8a18\u4e8b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<p>NanoDrop\u95a2\u9023\u8a18\u4e8b\uff1a<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tag\/nanodrop\/?CID=bid_pca_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nanodrop_maintenance_6_bid_ts_mbr_24053_Social_LAB\" target=\"_blank\" rel=\"noopener\">https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/tag\/nanodrop\/<\/a><\/p>\n\n\n\n<p>NanoDrop One \/ OneC\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u306b\u3064\u3044\u3066\u65b0\u3057\u304f\u52d5\u753b\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u3054\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002Web\u30b5\u30a4\u30c8\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/uv-vis-spectrophotometry\/instruments\/nanodrop\/resources.html?CID=bid_pca_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nanodrop_maintenance_6_bid_ts_mbr_24053_Social_LAB\" target=\"_blank\" rel=\"noopener\">thermofisher.com\/jp-nanodrop-setup<\/a>\uff09\u306b\u3042\u308b\u52d5\u753b\u8cc7\u6599\u3082\u4f75\u305b\u3066\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<br>\u307e\u305fNanoDrop\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u30b7\u30ea\u30fc\u30ba\u306b\u3054\u8208\u5473\u306e\u30e6\u30fc\u30b6\u30fc\u3055\u307e\u306f\u4ee5\u4e0b\u30ea\u30f3\u30af\u3088\u308a\u30c7\u30e2\u306e\u3054\u4f9d\u983c\u3082\u53ef\u80fd\u3067\u3059\u306e\u3067\u3054\u6d3b\u7528\u3044\u305f\u3060\u3051\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/nanodrop-inquiry-form.html?CID=bid_pca_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nanodrop_maintenance_6_bid_ts_mbr_24053_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<p>&nbsp;<\/p>\n\n\n\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01\u30fb\u5438\u5149\u5ea6\u6e2c\u5b9a\u3092\u5b9f\u65bd\u3055\u308c\u3066\u3044\u308b\u65b9\u30fb\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u3092\u3054\u5229\u7528\u30fb\u3054\u691c\u8a0e\u306e\u65b9Web\u30b5\u30a4\u30c8\uff08thermofisher.com\/jp-nanodrop-setup\uff09\u306b\u3042\u308b\u52d5\u753b\u8cc7\u6599\u3082\u4f75\u305b\u3066\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002 \u8efd\u5fae<\/p>\n","protected":false},"author":975,"featured_media":15757,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[103,229,241],"division":[],"class_list":{"0":"post-17800","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-nanodrop","9":"tag-229","10":"tag-nanodrop-dojo","11":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e\" \/>\n<meta property=\"og:description\" content=\"\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01\u30fb\u5438\u5149\u5ea6\u6e2c\u5b9a\u3092\u5b9f\u65bd\u3055\u308c\u3066\u3044\u308b\u65b9\u30fb\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u3092\u3054\u5229\u7528\u30fb\u3054\u691c\u8a0e\u306e\u65b9Web\u30b5\u30a4\u30c8\uff08thermofisher.com\/jp-nanodrop-setup\uff09\u306b\u3042\u308b\u52d5\u753b\u8cc7\u6599\u3082\u4f75\u305b\u3066\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002 \u8efd\u5fae\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-08-20T08:02:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-03T02:44:39+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"837\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e\",\"datePublished\":\"2024-08-20T08:02:12+00:00\",\"dateModified\":\"2025-10-03T02:44:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/\"},\"wordCount\":50,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/11\\\/nanodrop-dojo-bid-ts-3-image.jpg\",\"keywords\":[\"NanoDrop\",\"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\",\"\u9023\u8f09NanoDrop\u9053\u5834\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/\",\"name\":\"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/11\\\/nanodrop-dojo-bid-ts-3-image.jpg\",\"datePublished\":\"2024-08-20T08:02:12+00:00\",\"dateModified\":\"2025-10-03T02:44:39+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/11\\\/nanodrop-dojo-bid-ts-3-image.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2023\\\/11\\\/nanodrop-dojo-bid-ts-3-image.jpg\",\"width\":837,\"height\":720},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nanodrop-maintenance-6-bid-ts-mbr-24053\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/","og_locale":"ja_JP","og_type":"article","og_title":"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e","og_description":"\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01\u30fb\u5438\u5149\u5ea6\u6e2c\u5b9a\u3092\u5b9f\u65bd\u3055\u308c\u3066\u3044\u308b\u65b9\u30fb\u5fae\u91cf\u5206\u5149\u5149\u5ea6\u8a08\u3092\u3054\u5229\u7528\u30fb\u3054\u691c\u8a0e\u306e\u65b9Web\u30b5\u30a4\u30c8\uff08thermofisher.com\/jp-nanodrop-setup\uff09\u306b\u3042\u308b\u52d5\u753b\u8cc7\u6599\u3082\u4f75\u305b\u3066\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002 \u8efd\u5fae","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-08-20T08:02:12+00:00","article_modified_time":"2025-10-03T02:44:39+00:00","og_image":[{"width":837,"height":720,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e","datePublished":"2024-08-20T08:02:12+00:00","dateModified":"2025-10-03T02:44:39+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/"},"wordCount":50,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg","keywords":["NanoDrop","\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9","\u9023\u8f09NanoDrop\u9053\u5834"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/","name":"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg","datePublished":"2024-08-20T08:02:12+00:00","dateModified":"2025-10-03T02:44:39+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg","width":837,"height":720},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nanodrop-maintenance-6-bid-ts-mbr-24053\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u9023\u8f09NanoDrop\u9053\u5834 \u7b2c6\u56de\u3000\u6e2c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u3088\u3046\u3000\uff5e\u53f0\u5ea7\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u30fb\u5fdc\u7528\u7de81\uff5e"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":103,"label":"NanoDrop"},{"value":229,"label":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9"},{"value":241,"label":"\u9023\u8f09NanoDrop\u9053\u5834"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg",760,654,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":103,"name":"NanoDrop","slug":"nanodrop","term_group":0,"term_taxonomy_id":103,"taxonomy":"post_tag","description":"","parent":0,"count":15,"filter":"raw","meta":[]},{"term_id":229,"name":"\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9","slug":"%e3%83%a1%e3%83%b3%e3%83%86%e3%83%8a%e3%83%b3%e3%82%b9","term_group":0,"term_taxonomy_id":229,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":241,"name":"\u9023\u8f09NanoDrop\u9053\u5834","slug":"nanodrop-dojo","term_group":0,"term_taxonomy_id":241,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2023\/11\/nanodrop-dojo-bid-ts-3-image.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/17800","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=17800"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/17800\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/15757"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=17800"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=17800"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=17800"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=17800"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}