{"id":18162,"date":"2024-10-01T14:27:50","date_gmt":"2024-10-01T05:27:50","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=18162"},"modified":"2024-10-01T14:27:50","modified_gmt":"2024-10-01T05:27:50","slug":"sanger-seq-ce-1-gsd-ts-ce-24063","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/","title":{"rendered":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09"},"content":{"rendered":"<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u6ce2\u5f62\u30c7\u30fc\u30bf\u304c\u5e45\u5e83\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u5834\u5408\u3001\u9069\u5207\u306b\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u304c\u3055\u308c\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d\u6642\u306b\u6ce8\u76ee\u3059\u3079\u304d\u70b9\u3068\u3001\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f<\/h2>\n<p>\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f\u3001\u30d4\u30fc\u30af\u5e45\u304c\u5e83\u304f\u3001\u88fe\u91ce\u304c\u5e83\u304c\u3063\u3066\u3044\u308b\u5f62\u72b6\u306e\u30d4\u30fc\u30af\u3092\u6307\u3057\u307e\u3059\u3002<br \/>\n\u4f55\u3089\u304b\u306e\u539f\u56e0\u306b\u3088\u308a\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306e\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b\u3057\u305f\u5834\u5408\u3001DNA\u65ad\u7247\u306e\u6cf3\u52d5\u901f\u5ea6\u306b\u5e45\u304c\u751f\u3058\u3001\u305d\u306e\u7d50\u679c\u30d4\u30fc\u30af\u304c\u30d6\u30ed\u30fc\u30c9\u306e\u5f62\u72b6\u3067\u691c\u51fa\u3055\u308c\u307e\u3059\u3002\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u304c\u691c\u51fa\u3055\u308c\u3066\u3044\u308b\u9818\u57df\u306f\u3001\u96a3\u63a5\u3059\u308b\u30d4\u30fc\u30af\u306e\u88fe\u91ce\u304c\u91cd\u306a\u308a\u5408\u3046\u305f\u3081\u3001\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u306e\u30af\u30aa\u30ea\u30c6\u30a3\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u3002<\/p>\n<p>\u30c7\u30fc\u30bf\u5168\u4f53\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u3064\u3044\u3066\u306f\u3001Raw\u30c7\u30fc\u30bf\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>Raw\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d\u65b9\u6cd5\u306f\u3001\u4ee5\u4e0b\u30ea\u30f3\u30af\u5148\u306e\u30d6\u30ed\u30b0\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_1_gsd_ts_ce_24063_Social_LAB\" rel=\"noopener\" target=\"_blank\">https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/<\/a><br \/>\n<div id=\"attachment_18171\" style=\"width: 2570px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18171\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/ead917126de1aa3d0e5c87b208b83e4b-scaled.jpg\" alt=\"\u56f31. \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3000\u30c7\u30fc\u30bf\u4f8b\n\u4e0a\uff1aRawData\u3001\u4e0b\u6bb5\uff1aElectropherogram\" width=\"2560\" height=\"807\" class=\"size-full wp-image-18171\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/ead917126de1aa3d0e5c87b208b83e4b-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/ead917126de1aa3d0e5c87b208b83e4b-300x95.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/ead917126de1aa3d0e5c87b208b83e4b-1024x323.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/ead917126de1aa3d0e5c87b208b83e4b-768x242.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/ead917126de1aa3d0e5c87b208b83e4b-1536x484.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/ead917126de1aa3d0e5c87b208b83e4b-2048x645.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><p id=\"caption-attachment-18171\" class=\"wp-caption-text\">\u56f31. \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3000\u30c7\u30fc\u30bf\u4f8b<br \/>\u4e0a\uff1aRawData\u3001\u4e0b\u6bb5\uff1aElectropherogram<\/p><\/div><\/p>\n<p>\u7279\u306b\u9ad8\u5206\u5b50\u5074\u304c\u5206\u89e3\u80fd\u4f4e\u4e0b\u306e\u5f71\u97ff\u3092\u53d7\u3051\u3084\u3059\u3044\u305f\u3081\u3001\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u304c\u767a\u751f\u3057\u3084\u3059\u304f\u3001\u56f31\u306e\u4e0a\u6bb5RawData\u3067\u306f\u3001\u30c7\u30fc\u30bf\u524d\u534a\u306e\u30d4\u30fc\u30af\u5e45\u3068\u6bd4\u8f03\u3059\u308b\u3068\u3001\u5f8c\u534a\u306b\u5e45\u5e83\u306e\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u304c\u751f\u3058\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u4e0b\u6bb5\u6ce2\u5f62\u30c7\u30fc\u30bf\u306f\u3001\u4e0a\u6bb5Raw\u30c7\u30fc\u30bf\u8d64\u8272\u70b9\u7dda\u67a0\u5185\u306e\u9818\u57df\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u6ce2\u5f62\u30c7\u30fc\u30bf\u306e\u4e0a\u90e8\u306b\u8868\u793a\u3055\u308c\u3066\u3044\u308bQuality Value Bar\u3092\u898b\u308b\u3068\u3001QV20\uff0899%\uff09\u4ee5\u4e0b\u306e\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\uff08\u9ec4\u8272\u3001\u8d64\u8272\u306e\u30d0\u30fc\uff09\u304c\u591a\u304f\u767a\u751f\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h2>\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u304c\u767a\u751f\u3059\u308b\u4e3b\u306a\u539f\u56e0<\/h2>\n<p>\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u767a\u751f\u6642\u306e\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0\u3068\u3057\u3066\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u539f\u56e0\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n<p><b>\u6d88\u8017\u54c1\u306e\u52a3\u5316\uff08\u4f7f\u7528\u671f\u9650\u3001\u4f7f\u7528\u56de\u6570\u4e0a\u9650\u8d85\u904e\uff09<\/b><br \/>\n\u5404\u6d88\u8017\u54c1\u3067\u8a2d\u3051\u3089\u308c\u3066\u3044\u308b\u3001\u4f7f\u7528\u671f\u9650\u3001\u4f7f\u7528\u56de\u6570\u306e\u4e0a\u9650\u3092\u8d85\u904e\u3057\u3066\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u30dd\u30ea\u30de\u30fc<br \/>\n\u30dd\u30ea\u30de\u30fc\u306e\u7db2\u76ee\u69cb\u9020\u304c\u5d29\u308c\u3001\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u30d4\u30fc\u30af\u304c\u30d6\u30ed\u30fc\u30c9\u3068\u306a\u3063\u3066\u691c\u51fa\u3055\u308c\u307e\u3059\u3002<\/li>\n<li>\u30d0\u30c3\u30d5\u30a1\u30fc<br \/>\n\u30e9\u30f3\u4e2d\u306b\u96fb\u6d41\u5024\u304c\u4e0d\u5b89\u5b9a\u3068\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\u3060\u3051\u3067\u306a\u304f\u3001\u96fb\u6d41\u5024\u4e0d\u5b89\u5b9a\u30a8\u30e9\u30fc\u306b\u3088\u308a\u3001\u9014\u4e2d\u3067\u30e9\u30f3\u304c\u4e2d\u65ad\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<li>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30a2\u30ec\u30a4<br \/>\n\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306e\u5185\u58c1\u306b\u84c4\u7a4d\u3057\u305f\u6c5a\u308c\u304c\u3001\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3092\u5f15\u304d\u8d77\u3053\u3059\u539f\u56e0\u3068\u306a\u308a\u307e\u3059\u3002<\/li>\n<li>\u30bb\u30d7\u30bf\u306e\u7e70\u308a\u8fd4\u3057\u4f7f\u7528<br \/>\n96\u30d7\u30ec\u30fc\u30c8\u30018\u9023\u30c1\u30e5\u30fc\u30d6\u3001\u9670\u6975\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u30bb\u30d7\u30bf\u306f\u3001\u4e00\u56de\u4f7f\u3044\u5207\u308a\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4f55\u5ea6\u3082\u7e70\u308a\u8fd4\u3057\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u30b9\u30ea\u30c3\u30c8\u90e8\u5206\u306b\u6c5a\u308c\u304c\u84c4\u7a4d\u3057\u3001\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u304c\u767a\u751f\u3059\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<br \/><b>\u88c5\u7f6e\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u4e0d\u8db3\u3000\u203bApplied Biosystems\u2122 3500\u30b7\u30ea\u30fc\u30ba\u3001Applied Biosystems\u2122 SeqStudio\u2122 Flex\u30b7\u30ea\u30fc\u30ba\u30b8\u30a7\u30cd\u30c6\u30a3\u30c3\u30af\u30a2\u30ca\u30e9\u30a4\u30b6\u3001Applied Biosystems\u2122 3730xl DNA\u30a2\u30ca\u30e9\u30a4\u30b6\uff08latest version\uff09<\/b><br \/>\n\u5b9a\u671f\u7684\u306a\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u5b9f\u65bd\u304c\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u306b\u3001\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<li>\u30d6\u30ed\u30c3\u30af\u6d17\u6d44<br \/>\n\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u8a66\u85ac\uff083500\u30b7\u30ea\u30fc\u30ba\u3001SeqStudio Flex\u30b7\u30ea\u30fc\u30ba\uff09\uff0f\u8d85\u7d14\u6c34\u307e\u305f\u306f\u8131\u30a4\u30aa\u30f3\u6c34\uff083730xl LV\uff09\u3092\u7528\u3044\u3066\u3001\u5b9a\u671f\u7684\u306a\u30d6\u30ed\u30c3\u30af\u6d17\u6d44\u3092\u5b9f\u65bd\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u3001\u30d6\u30ed\u30c3\u30af\u5185\u306b\u30b5\u30f3\u30d7\u30eb\u7531\u6765\u306e\u6c5a\u308c\u3001\u53e4\u3044\u30dd\u30ea\u30de\u30fc\u304c\u6ede\u7559\u3057\u3001\u305d\u306e\u307e\u307e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u5185\u306b\u6301\u3061\u8fbc\u307e\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u30dd\u30ea\u30de\u30fc\u304c\u30d6\u30ed\u30c3\u30af\u5185\u3067\u7d50\u6676\u5316\u3059\u308b\u3068\u3001\u30c1\u30a7\u30c3\u30af\u30d0\u30eb\u30d6\uff08\u6d41\u8def\u5207\u308a\u66ff\u3048\u5f01\uff09\u306b\u7d50\u6676\u304c\u8a70\u307e\u308a\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306b\u30dd\u30ea\u30de\u30fc\u304c\u9069\u5207\u306b\u5145\u586b\u3055\u308c\u305a\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u3002<\/li>\n<li>\u30a6\u30a9\u30fc\u30bf\u30fc\u30c8\u30e9\u30c3\u30d7\u6d17\u6d44<br \/>\n\u30d4\u30b9\u30c8\u30f3\u5468\u8fba\u3067\u30dd\u30ea\u30de\u30fc\u304c\u51dd\u56fa\u3057\u306a\u3044\u3088\u3046\u6c34\u3092\u901a\u3057\u3001\u5ec3\u6db2\u30dc\u30c8\u30eb\u306b\u306f\u5e38\u306b\u534a\u5206\u7a0b\u5ea6\u6c34\u304c\u5165\u3063\u3066\u3044\u308b\u72b6\u614b\u3092\u4fdd\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u30c8\u30e9\u30c3\u30d7\u5185\u304c\u4e7e\u71e5\u3057\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u306f\u3001\u30d4\u30b9\u30c8\u30f3\u304c\u30b9\u30e0\u30fc\u30ba\u306b\u52d5\u304b\u305a\u3001\u30dd\u30ea\u30de\u30fc\u304c\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u5185\u306b\u9069\u5207\u306b\u5145\u586b\u3055\u308c\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b\u3057\u3001\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u304c\u751f\u3058\u308b\u539f\u56e0\u3068\u306a\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n<div id=\"attachment_18172\" style=\"width: 501px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18172\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/7bfd577a98aab6438377b6192a2f2f50.jpg\" alt=\"\u56f32. \u30a6\u30a9\u30fc\u30bf\u30fc\u30c8\u30e9\u30c3\u30d7\uff083500\u30b7\u30ea\u30fc\u30ba\uff09\" width=\"491\" height=\"428\" class=\"size-full wp-image-18172\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/7bfd577a98aab6438377b6192a2f2f50.jpg 2230w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/7bfd577a98aab6438377b6192a2f2f50-300x261.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/7bfd577a98aab6438377b6192a2f2f50-1024x892.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/7bfd577a98aab6438377b6192a2f2f50-768x669.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/7bfd577a98aab6438377b6192a2f2f50-1536x1338.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/7bfd577a98aab6438377b6192a2f2f50-2048x1784.jpg 2048w\" sizes=\"auto, (max-width: 491px) 100vw, 491px\" \/><p id=\"caption-attachment-18172\" class=\"wp-caption-text\">\u56f32. \u30a6\u30a9\u30fc\u30bf\u30fc\u30c8\u30e9\u30c3\u30d7\uff083500\u30b7\u30ea\u30fc\u30ba\uff09<\/p><\/div>\n<h2>\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3000\u305d\u306e\u4ed6\u30c7\u30fc\u30bf\u4f8b<\/h2>\n<p><b>\u30fb\u5206\u96e2\u80fd\u4f4e\u4e0b\uff1a\u30e9\u30f3\u958b\u59cb\u6642<\/b><br \/>\n<div id=\"attachment_18173\" style=\"width: 2570px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18173\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/6ec376cf4119b60cc33a71155d08b262-scaled.jpg\" alt=\"\u56f33. \u30e9\u30f3\u958b\u59cb\u6642\u306b\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b\" width=\"2560\" height=\"769\" class=\"size-full wp-image-18173\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/6ec376cf4119b60cc33a71155d08b262-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/6ec376cf4119b60cc33a71155d08b262-300x90.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/6ec376cf4119b60cc33a71155d08b262-1024x308.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/6ec376cf4119b60cc33a71155d08b262-768x231.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/6ec376cf4119b60cc33a71155d08b262-1536x461.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/6ec376cf4119b60cc33a71155d08b262-2048x615.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><p id=\"caption-attachment-18173\" class=\"wp-caption-text\">\u56f33. \u30e9\u30f3\u958b\u59cb\u6642\u306b\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b<\/p><\/div><\/p>\n<table>\n<tbody>\n<tr bgcolor=\"white\">\n<td style=\"text-align: center\" width=\"400\" bgcolor=\"silver\"><b>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0<\/b><\/td>\n<td style=\"text-align: center\" width=\"200\" bgcolor=\"silver\"><b>\u5bfe\u51e6\u6cd5<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"400\">\u7cbe\u88fd\u30ad\u30c3\u30c8 Applied Biosystems\u2122 BigDye\u2122 X Terminator Purification Kit \u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3001X Terminator Solution\u3001<br \/>\u307e\u305f\u306f\u30d7\u30ec\u30df\u30c3\u30af\u30b9\u304c25\u2103\u4ee5\u4e0a\u306e\u6e29\u5ea6\u306b\u3055\u3089\u3055\u308c\u305f\u3002<\/td>\n<td style=\"text-align: left\" width=\"200\">BigDye X Terminator Purification Kit\u306f\u3001\u4fdd\u7ba1\u6642\u306f\u51b7\u8535\u4fdd\u7ba1\u3002\u4f7f\u7528\u958b\u59cb\u524d\u306b\u3001\u5ba4\u6e29\u306b\u623b\u3057\u4f7f\u7528\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"400\">X Terminator Solution, SAM solution\u3092\u6dfb\u52a0\u5f8c\u3001<br \/>\u30b7\u30a7\u30fc\u30ab\u30fc\u3067\u64b9\u62cc\u3059\u308b\u969b\u3001\u63a8\u5968\u306e\u56de\u8ee2\u6570\u3001\u652a\u62cc\u6642\u9593\u3092\u8d85\u3048\u3066\u3044\u308b\u3002<\/td>\n<td style=\"text-align: left\" width=\"200\">\u63a8\u5968\u306e\u56de\u8ee2\u6570\u30fb\u64b9\u62cc\u6642\u9593\u306b\u3066\u884c\u3046\u3002<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"400\">\u30b7\u30a7\u30fc\u30ab\u30fc\u3067\u64b9\u62cc\u3059\u308b\u969b\u3001\u6eb6\u6db2\u306e\u6e29\u5ea6\u304c\u4e0a\u304c\u3063\u3066\u3044\u308b\u3002<\/td>\n<td style=\"text-align: left\" width=\"200\">\u63a8\u5968\u306e\u30b7\u30a7\u30fc\u30ab\u30fc\u3092\u4f7f\u7528\u3059\u308b\u3002<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"400\">\u6709\u52b9\u671f\u9650\u304c\u5207\u308c\u305fBigDye XTerminator Purification Kit\u3092<br \/>\u4f7f\u7528\u3057\u3066\u3044\u308b\u3002<\/td>\n<td style=\"text-align: left\" width=\"200\">\u671f\u9650\u5185\u306e\u8a66\u85ac\u3092\u4f7f\u7528\u3059\u308b\u3002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>\u30fb\u5206\u96e2\u80fd\u4f4e\u4e0b\uff1a\u30e9\u30f3\u4e2d\u9593<\/b><br \/>\n<div id=\"attachment_18174\" style=\"width: 2570px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18174\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/a387377ad33ae96e054475ce10eb015d-scaled.jpg\" alt=\"\u56f34. \u30e9\u30f3\u306e\u4e2d\u9593\u3067\u5206\u96e2\u80fd\u4f4e\u4e0b\" width=\"2560\" height=\"737\" class=\"size-full wp-image-18174\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/a387377ad33ae96e054475ce10eb015d-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/a387377ad33ae96e054475ce10eb015d-300x86.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/a387377ad33ae96e054475ce10eb015d-1024x295.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/a387377ad33ae96e054475ce10eb015d-768x221.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/a387377ad33ae96e054475ce10eb015d-1536x442.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/a387377ad33ae96e054475ce10eb015d-2048x589.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><p id=\"caption-attachment-18174\" class=\"wp-caption-text\">\u56f34. \u30e9\u30f3\u306e\u4e2d\u9593\u3067\u5206\u96e2\u80fd\u4f4e\u4e0b<\/p><\/div><\/p>\n<p>\u30e9\u30f3\u4e2d\u9593\u306b\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n<table>\n<tbody>\n<tr bgcolor=\"white\">\n<td style=\"text-align: center\" width=\"200\" bgcolor=\"silver\"><b>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0<\/b><\/td>\n<td style=\"text-align: center\" width=\"400\" bgcolor=\"silver\"><b>\u5bfe\u51e6\u6cd5<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"200\">\u96fb\u6c17\u6cf3\u52d5\u4e2d\u306b\u3001\u6c17\u6ce1\u304c\u767a\u751f\u3057\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u5185\u306b\u5b58\u5728\u3057\u3066\u3044\u308b\u3002<\/td>\n<td style=\"text-align: left\" width=\"400\">\u540c\u3058\u30d7\u30ec\u30fc\u30c8\u3092\u518d\u30e9\u30f3\u3059\u308b<br \/>\n\uff08\u6b21\u306e\u30e9\u30f3\u958b\u59cb\u6642\u306b\u65b0\u3057\u3044\u30dd\u30ea\u30de\u30fc\u304c\u5145\u586b\u3055\u308c\u3001\u6c17\u6ce1\u304c\u629c\u3051\u308b\uff09\u3002<br \/>\n\u6c17\u6ce1\u304c\u767a\u751f\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u4e0b\u56f3\u306e\u3088\u3046\u306a\u30b9\u30d1\u30a4\u30af\u30ce\u30a4\u30ba\u304c\u767a\u751f\u3059\u308b\u5834\u5408\u3082\u3042\u308b\u304c\u3001\u540c\u69d8\u306b\u540c\u3058\u30d7\u30ec\u30fc\u30c8\u3092\u518d\u30e9\u30f3\u3059\u308b\u3002<br \/>\n<div id=\"attachment_18183\" style=\"width: 360px\" class=\"wp-caption aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f.jpg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18183\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f.jpg\" alt=\"\u56f35. \u30b9\u30d1\u30a4\u30af\u30ce\u30a4\u30ba\" width=\"350\" height=\"107\" class=\"size-full wp-image-18183\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f.jpg 2333w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f-300x92.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f-1024x314.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f-768x235.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f-1536x471.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b05b6d75a6f93b05bddab8d5843d387f-2048x628.jpg 2048w\" sizes=\"auto, (max-width: 350px) 100vw, 350px\" \/><\/a><p id=\"caption-attachment-18183\" class=\"wp-caption-text\">\u56f35. \u30b9\u30d1\u30a4\u30af\u30ce\u30a4\u30ba<br \/>\u203b\u753b\u50cf\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068\u62e1\u5927\u8868\u793a\u3067\u304d\u307e\u3059<\/p><\/div><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"200\">\u30bb\u30d7\u30bf\u3092\u6d17\u6d44\u3057\u305f\u969b\u306e\u85ac\u54c1\u306a\u3069\u306b\u3088\u308b\u6c5a\u67d3\u3002<\/td>\n<td style=\"text-align: left\" width=\"400\">\u65b0\u3057\u3044\u30bb\u30d7\u30bf\u3092\u4f7f\u7528\u3059\u308b\uff08\u30bb\u30d7\u30bf\u306f1\u56de\u4f7f\u3044\u5207\u308a\u3092\u63a8\u5968\uff09\u3002<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"200\">\u30e9\u30f3\u958b\u59cb\u6642\u306e\u30dd\u30ea\u30de\u30fc\u5145\u586b\u304c\u4e0d\u5341\u5206\u3002<\/td>\n<td style=\"text-align: left\" width=\"400\">\u30dd\u30ea\u30de\u30fc\u306e\u6f0f\u308c\u304c\u306a\u3044\u304b\u3092\u78ba\u8a8d\u3002<br \/>\n<u>3500\u30b7\u30ea\u30fc\u30ba\u3001SeqStudio Flex\u30b7\u30ea\u30fc\u30ba\u30013730xl LV\uff1a<\/u><br \/>\n\u30a2\u30ec\u30a4\u30dd\u30fc\u30c8\u306b\u7de9\u307f\u304c\u306a\u3044\u304b\u3002\u7de9\u3093\u3067\u3044\u308b\u5834\u5408\u306f\u7de0\u3081\u76f4\u3059\u3002<br \/>\n\u30d6\u30ed\u30c3\u30af\u6d17\u6d44\u3092\u5b9f\u65bd\u3057\u3066\u3044\u306a\u3044\u5834\u5408\u306f\u3001\u30c1\u30a7\u30c3\u30af\u30d0\u30eb\u30d6\u306b\u7d50\u6676\u304c\u8a70\u307e\u308a\u3001\u9069\u5207\u306b\u30dd\u30ea\u30de\u30fc\u304c\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u306b\u5145\u586b\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u3082\u3042\u308b\u305f\u3081\u3001\u30d6\u30ed\u30c3\u30af\u6d17\u6d44\u3092\u5b9f\u65bd\u3059\u308b\u3002<br \/>\n<u>Applied Biosystems\u2122 SeqStudio\u2122\u30b8\u30a7\u30cd\u30c6\u30a3\u30c3\u30af\u30a2\u30ca\u30e9\u30a4\u30b6\uff1a<\/u><br \/>\n\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u53d6\u308a\u51fa\u3057\u3001\u30dd\u30ea\u30de\u30fc\u306e\u6f0f\u308c\u304c\u306a\u3044\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3002<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u5206\u96e2\u80fd\u304c\u4f4e\u4e0b\u3057\u3001\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3092\u5f15\u304d\u8d77\u3053\u3059\u4e3b\u306a\u8981\u56e0\u3068\u3057\u3066\u3001<\/p>\n<ol>\n<li>\u4f7f\u7528\u671f\u9650\u3001\u56de\u6570\u3092\u8d85\u904e\u3057\u305f\u6d88\u8017\u54c1\u306e\u4f7f\u7528<\/li>\n<li>\u88c5\u7f6e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u5b9f\u65bd\u4e0d\u8db3<\/li>\n<\/ol>\n<p>\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<br \/>\n\u826f\u597d\u306a\u30c7\u30fc\u30bf\u53d6\u5f97\u306e\u305f\u3081\u306b\u3082\u3001\u6d88\u8017\u54c1\u306f\u671f\u9650\u5185\u3001\u63a8\u5968\u4f7f\u7528\u56de\u6570\u5185\u3067\u4f7f\u7528\u3057\u3001\u5b9a\u671f\u7684\u306a\u88c5\u7f6e\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u5b9f\u65bd\u3092\u304a\u9858\u3044\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u5f0a\u793e\u3067\u306f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u8b1b\u7fd2\u3082\u9069\u6642\u958b\u50ac\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u6b63\u3057\u3044\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u65b9\u6cd5\u306e\u7fd2\u5f97\u306b\u662f\u975e\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/ab3500-ga.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_1_gsd_ts_ce_24063_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u5b8c\u5168\u30de\u30b9\u30bf\u30fc\uff01\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30b3\u30fc\u30b9 \u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\uff082\uff09\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u8b1b\u7fd2 \uff5eApplied Biosystems 3500\/3500xL \u30b8\u30a7\u30cd\u30c6\u30a3\u30c3\u30af\u30a2\u30ca\u30e9\u30a4\u30b6\u7de8\uff5e | Thermo Fisher Scientific &#8211; JP<\/a><\/p>\n<h3>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3000\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_1_gsd_ts_ce_24063_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h3>\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30e9\u30fc\u30cb\u30f3\u30b0\u30bb\u30f3\u30bf\u30fc<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sequencing-learning-center.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_1_gsd_ts_ce_24063_Social_LAB\" rel=\"noopener\" target=\"_blank\">https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sequencing-learning-center.html<\/a><\/p>\n<h3>\u30b8\u30a7\u30cd\u30c6\u30a3\u30c3\u30af\u30a2\u30ca\u30e9\u30a4\u30b6\u30b7\u30b9\u30c6\u30e0<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-technology-accessories.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_1_gsd_ts_ce_24063_Social_LAB\" rel=\"noopener\" target=\"_blank\">https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-sequencing-technology-accessories.html<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u6ce2\u5f62\u30c7\u30fc\u30bf\u304c\u5e45\u5e83\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u5834\u5408\u3001\u9069\u5207\u306b\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u304c\u3055\u308c\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d\u6642\u306b\u6ce8\u76ee\u3059\u3079\u304d\u70b9\u3068\u3001\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f\u3001\u30d4<\/p>\n","protected":false},"author":975,"featured_media":18175,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[172,183],"division":[],"class_list":{"0":"post-18162","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-ce","9":"tag-sanger-seq","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09\" \/>\n<meta property=\"og:description\" content=\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u6ce2\u5f62\u30c7\u30fc\u30bf\u304c\u5e45\u5e83\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u5834\u5408\u3001\u9069\u5207\u306b\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u304c\u3055\u308c\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d\u6642\u306b\u6ce8\u76ee\u3059\u3079\u304d\u70b9\u3068\u3001\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f\u3001\u30d4\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-10-01T05:27:50+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1351\" \/>\n\t<meta property=\"og:image:height\" content=\"1356\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09\",\"datePublished\":\"2024-10-01T05:27:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/\"},\"wordCount\":132,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"keywords\":[\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\",\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/\",\"name\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"datePublished\":\"2024-10-01T05:27:50+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"width\":1351,\"height\":1356},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-1-gsd-ts-ce-24063\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09","og_description":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u6ce2\u5f62\u30c7\u30fc\u30bf\u304c\u5e45\u5e83\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u5834\u5408\u3001\u9069\u5207\u306b\u30d9\u30fc\u30b9\u30b3\u30fc\u30eb\u304c\u3055\u308c\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d\u6642\u306b\u6ce8\u76ee\u3059\u3079\u304d\u70b9\u3068\u3001\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002 \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f \u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u3068\u306f\u3001\u30d4","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-10-01T05:27:50+00:00","og_image":[{"width":1351,"height":1356,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09","datePublished":"2024-10-01T05:27:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/"},"wordCount":132,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","keywords":["\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/","name":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","datePublished":"2024-10-01T05:27:50+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","width":1351,"height":1356},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-1-gsd-ts-ce-24063\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u5206\u96e2\u80fd\u306e\u4f4e\u4e0b\u3000\uff08\u30d6\u30ed\u30fc\u30c9\u30d4\u30fc\u30af\u306e\u767a\u751f\uff09"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":172,"label":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"},{"value":183,"label":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782-1020x1024.jpg",760,763,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":536,"filter":"raw","meta":[],"cat_ID":156,"category_count":536,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":172,"name":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","slug":"ce","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]},{"term_id":183,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","slug":"sanger-seq","term_group":0,"term_taxonomy_id":183,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18162","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=18162"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18162\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/18175"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=18162"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=18162"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=18162"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=18162"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}