{"id":183,"date":"2015-11-19T00:00:00","date_gmt":"2015-11-19T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/"},"modified":"2025-04-17T15:12:28","modified_gmt":"2025-04-17T06:12:28","slug":"qpcr-faq","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/","title":{"rendered":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f"},"content":{"rendered":"<p>\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n<h2>Q: \u4e00\u5b9a\u91cf\u306e\u30d2\u30c8\u30b1\u3099\u30ce\u30e0DNA\u306b\u542b\u307e\u308c\u308b\u30b3\u30d2\u309a\u30fc\u6570\u306f\u3044\u304f\u3064\u3066\u3099\u3059\u304b?<\/h2>\n<p>1\u30b1\u3099\u30ce\u30e0\u30b3\u30d2\u309a\u30fc = 3\u00d710<sup>9<\/sup>bp<br \/>\n1bp = 618g\/mol<br \/>\n1\u30b1\u3099\u30ce\u30e0\u30b3\u30d2\u309a\u30fc =(3\u00d710<sup>9<\/sup>bp)\u00d7(618g\/mol\/bp)<br \/>\n= 1.85\u00d710<sup>12<\/sup>g\/mol =(1.85\u00d710<sup>12<\/sup>g\/mol)\u00d7 (1 mole\/6.02 \u00d7 10<sup>23<\/sup>(\u30a2\u30db\u3099\u30ab\u3099\u30c8\u3099\u30ed\u6570)<br \/>\n= 3.08\u00d710<sup>-12<\/sup>g<\/p>\n<p>\u5404\u4f53\u7d30\u80de\u306b\u306f6.16pg(\u7cbe\u5b50\u304a\u3088\u3072\u3099\u5375\u7d30\u80de\u306b\u306f3.08pg)\u306e DNA\u304b\u3099\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u30023.08pg\u306e\u30d2\u30c8DNA\u306b\u306f\u3001\u3059\u3078\u3099\u3066\u306e\u975e\u53cd\u5fa9\u914d\u5217\u304b\u30991\u30b3\u30d2\u309a\u30fc\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u305f\u304b\u3099\u3063\u3066\u3001 100ng\u306e\u30b1\u3099\u30ce\u30e0DNA\u306b\u306f\u3001100,000pg\/3.08pg = ~33,000\u30b3\u30d2\u309a\u30fc\u304b\u3099\u3001\u3059\u306a\u308f\u30611ng\u306eDNA\u306b\u306f330\u30b3\u30d2\u309a\u30fc\u304b\u3099\u542b\u307e\u308c\u307e\u3059\u3002<\/p>\n<h2>Q: \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30a2\u30c3\u30bb\u30a4\u306e\u52b9\u7387\u306b\u914d\u616e\u304b\u3099\u5fc5\u8981\u306a\u7406\u7531\u306f\u4f55\u3066\u3099\u3059\u304b?<\/h2>\n<p>\u4f8b\u3048\u306f\u30992\u3064\u306e\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u3092\u6bd4\u8f03\u3057\u305f\u3044\u5834\u5408(\u4f8b\u3048\u306f\u3099\u3001\u30ce\u30fc\u30de\u30e9\u30a4\u30b5\u3099\u30fc\u907a\u4f1d\u5b50\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408)\u306b\u306f\u3001\u6e2c\u5b9a\u3055\u308c\u305f C<sub>t<\/sub> \u5024\u304b\u3099 PCR \u8a66\u85ac\u4e2d\u306b\u5b58\u5728\u3059\u308b\u6c5a\u67d3\u7269\u8cea\u306b\u3088\u308b\u5f71\u97ff\u3092\u53d7\u3051\u3066\u3044\u306a\u3044\u3068\u3044\u3046\u3053\u3068\u3001\u3042\u308b\u3044\u306f\u6700\u9069\u5316\u304b\u3099\u884c\u308f\u308c\u3066\u3044\u306a\u3044\u30a2\u30c3\u30bb\u30a4\u306b\u8d77\u56e0\u3059\u308b\u3082\u306e\u3066\u3099\u306f\u306a\u3044\u3068\u3044\u3046\u3053\u3068\u3092\u78ba\u8a3c\u3059\u308b\u305f\u3081\u306bPCR\u52b9\u7387\u3092\u78ba\u8a8d\u3057\u3066\u304a\u304f\u3053\u3068\u304b\u3099\u5fc5\u8981\u3066\u3099\u3059\u3002<\/p>\n<h2>Q: \u79c1\u306e\u884c\u3063\u305f\u5b9f\u9a13\u3066\u3099\u306f\u3001\u3088\u308a\u6fc3\u5ea6\u306e\u9ad8\u3044\u30c6\u30f3\u30d5\u309a\u30ec\u30fc\u30c8\u304b\u3089\u3088\u308a\u52b9\u7387\u306e\u4f4e\u3044\u5897\u5e45\u66f2\u7dda\u304b\u3099\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u5e0c\u91c8\u8a66\u6599\u304b\u3089\u5f97\u3089\u308c\u305f\u50be\u304d\u306f\u20133.4\u3001R<sup>2<\/sup>\u5024\u306f0.99\u3066\u3099\u3057\u305f\u304b\u3099\u3001\u9ad8\u6fc3\u5ea6\u306e\u8a66\u6599\u304b\u3089\u5f97\u3089\u308c\u305f\u50be\u304d\u306f\u20132.5\u3001R<sup>2<\/sup>\u5024\u306f0.84\u3066\u3099\u3057\u305f\u3002<\/h2>\n<p>\u8a66\u6599\u4e2d\u306b\u542b\u307e\u308c\u308b\u4f55\u304b\u304b\u3099PCR\u3092\u963b\u5bb3\u3057\u3066\u3044\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u5e0c\u91c8\u3055\u308c\u305f\u8a66\u6599\u304b\u3089\u3088\u308a\u9ad8\u3044\u52b9\u7387\u304b\u3099\u5f97\u3089\u308c\u305f\u306e\u306f \u3001\u963b\u5bb3\u7269\u8cea(\u5869\u307e\u305f\u306f\u305d\u306e\u4ed6\u306e\u6210\u5206)\u304b\u3099\u3001\u963b\u5bb3\u52b9\u679c\u3092\u793a\u3059\u6fc3\u5ea6\u4ee5\u4e0b\u306b\u5e0c\u91c8\u3055\u308c\u305f\u305f\u3081\u3066\u3099\u3059\u3002\u3053\u306e\u73fe\u8c61\u306b\u95a2\u3059\u308b\u8aac\u660e\u306f\u4ee5\u4e0b\u306b\u793a\u3059\u53c2\u8003\u6587\u732e\u306a\u3068\u3099\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n<ul>\n<li>Ramakers C, Ruijter JM, Deprez RH et al.(2003) <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/12618301\" target=\"_blank\" rel=\"noopener noreferrer\">Assumption-free analysis of quantitative real-time polymerase chain reaction (PCR) data.<\/a> Neurosci Lett 339:62\u201366.<\/li>\n<li>Liu W and Saint DA(2002) <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/11846375\" target=\"_blank\" rel=\"noopener noreferrer\">A new quantitative method of real time reverse transcription polymerase chain reaction assay based on simulation of polymerase chain reaction kinetics<\/a>. Anal Biochem 302:52\u201359.<\/li>\n<li>Bar T, St\u00e5hlberg A, Muszta A et al.(2003) <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/12930979\" target=\"_blank\" rel=\"noopener noreferrer\">Kinetic outlier detection (KOD) in real-time PCR.<\/a> Nucleic Acids Res 31:e105.<\/li>\n<\/ul>\n<h2>Q: \u52b9\u7387\u306e\u7570\u306a\u308bPCR\u53cd\u5fdc\u9593\u306eC<sub>t<\/sub>\u5024\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u306f\u53ef\u80fd\u3066\u3099\u3057\u3087\u3046\u304b?<\/h2>\n<p>\u52b9\u7387\u306e\u7570\u306a\u308bPCR\u53cd\u5fdc\u9593\u306eC<sub>t<\/sub>\u5024\u3092\u6bd4\u8f03\u3059\u308b\u3053\u3068\u306f\u3066\u3099\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u7406\u7531\u306f\u3001\u2206\u2206C<sub>t<\/sub>\u306e\u7b97\u51fa\u304b\u3099PCR\u52b9\u7387\u306f\u540c\u7b49\u3066\u3099\u3042\u308b\u3068\u3044\u3046\u4eee\u5b9a\u306e\u4e0b\u306b\u884c\u308f\u308c\u3066\u3044\u308b\u305f\u3081\u3066\u3099\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u672a\u77e5\u306e\u8a66\u6599\u306e\u5b9a\u91cf\u3092\u884c\u3046\u524d\u306b\u30b7\u30b9\u30c6\u30e0\u306e\u6700\u9069\u5316\u3092\u884c\u3046\u3053\u3068\u304b\u3099\u5fc5\u8981\u3066\u3099\u3059\u3002\u307e\u305f\u306f\u691c\u91cf\u7dda\u6cd5\u3092\u7528\u3044\u3066\u52b9\u7387\u3092\u88dc\u6b63\u3057\u305f\u5b9a\u91cf\u3092\u884c\u3046\u3053\u3068\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059\u3002<\/p>\n<h2>Q: \u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u3068\u306f\u4f55\u3066\u3099\u3059\u304b\uff1f \u306a\u305b\u3099\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u3092\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u4f7f\u7528\u3059\u308b\u306e\u3066\u3099\u3059\u304b?<\/h2>\n<p>\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u3068\u306f\u3001\u30d5\u309a\u30e9\u30a4\u30de\u30fc\u307e\u305f\u306f\u30d5\u309a\u30ed\u30fc\u30d5\u3099\u306b\u7d50\u5408\u3055\u305b\u305f\u5206\u5b50\u3066\u3099\u3001\u30d5\u309a\u30e9\u30a4\u30de\u30fc\u307e\u305f\u306f\u30d5\u309a\u30ed\u30fc\u30d5\u3099\u306b\u7d50\u5408\u3057\u3066\u3044\u308b\u86cd\u5149\u8272\u7d20\u304b\u3089\u306e\u767a\u5149\u3092\u6d88\u5149\u3057\u307e\u3059\u3002\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u306f\u4e00\u822c\u7684\u306b\u30d5\u309a\u30ed\u30fc\u30d5\u3099\u3092\u30d8\u3099\u30fc\u30b9\u3068\u3059\u308b\u30a2\u30c3\u30bb\u30a4\u306b\u4f7f\u7528\u3055\u308c\u3001\u540c\u4e00\u306e\u30aa\u30ea\u30b3\u3099\u306b\u7d50\u5408\u3057\u3066\u3044\u308b\u86cd\u5149\u8272\u7d20\u304b\u3089\u767a\u5149\u3055\u308c\u308b\u86cd\u5149\u3092\u6d88\u5149\u3057\u305f\u308a\u3042\u308b\u3044\u306f\u305d\u306e\u6ce2\u9577\u3092\u5909\u5316\u3055\u305b\u305f\u308a\u3057\u307e\u3059\u3002\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u306e\u3053\u306e\u4f5c\u7528\u306f\u4e00\u822c\u7684\u306b\u306fFRET(\u86cd\u5149\u5171\u9cf4\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u79fb\u52d5)\u306b\u3088\u308a\u751f\u3057\u3099\u307e\u3059\u3002\u86cd\u5149\u8272\u7d20\u304b\u3099\u52b1\u8d77\u3055\u308c\u308b\u3068\u305d\u306e\u30a8\u30cd\u30eb\u30ad\u3099\u30fc\u306f\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u306b\u8ee2\u79fb\u3055\u308c\u3001\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u304b\u3099\u7570\u306a\u308b(\u3088\u308a\u9577\u3044)\u6ce2\u9577\u3066\u3099\u767a\u5149\u3057\u307e\u3059\u3002\u4e00\u822c\u7684\u306a\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u306b\u306f\u3001TAMRA\u2122\u8272\u7d20\u3001\u304a\u3088\u3072\u3099\u975e\u86cd\u5149\u6027\u306e\u30af\u30a8\u30f3\u30c1\u30e3\u30fc\u306a\u3068\u3099\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>Q:\u3068\u3099\u306e\u3088\u3046\u306a\u5834\u5408\u306b\u30012-Step\u3066\u3099\u306f\u306a\u304f1-Step\u306eqRT-PCR\u3092\u4f7f\u7528\u3059\u308b\u306e\u3066\u3099\u3057\u3087\u3046\u304b?<\/h2>\n<p>2-Step qRT-PCR\u306f\u3001\u5358\u4e00\u306eRNA\u8a66\u6599\u304b\u3089\u8907\u6570\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306b\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002 2-Step qRT-PCR\u3066\u3099\u306f\u3001\u3055\u3089\u306b\u5c06\u6765\u306e\u89e3\u6790\u7528\u306bcDNA\u3092\u4fdd\u5b58\u3057\u3066\u304a\u304f\u3053\u3068\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059\u3002\u3057\u304b\u3057\u3001\u591a\u6570\u306e\u8a66\u6599\u3092\u89e3\u6790\u3059\u308b\u5834\u5408\u306b\u306f1-Step qRT-PCR\u306e\u307b\u3046\u304b\u3099\u64cd\u4f5c\u306f\u5bb9\u6613\u3066\u3099\u3001cDNA\u5408\u6210\u3068\u5897\u5e45\u306e\u9593\u306b\u30c1\u30e5\u30fc\u30d5\u3099\u3092\u958b\u3051\u308b\u5fc5\u8981\u304b\u3099\u306a\u3044\u305f\u3081\u3001\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30cf\u3099\u30fc\u306b\u3088\u308b\u6c5a\u67d3\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059\u3002\u3059\u3078\u3099\u3066\u306ecDNA\u8a66\u6599\u3092\u5897\u5e45\u306b\u4f7f\u7528\u3059\u308b\u305f\u3081\u30011-Step qRT-PCR\u306f\u3088\u308a\u611f\u5ea6\u304b\u3099\u9ad8\u304f\u3001\u308f\u3059\u3099\u304b0.1pg\u306e\u30c8\u30fc\u30bf\u30ebRNA\u3066\u3099\u3082\u89e3\u6790\u304c\u53ef\u80fd\u3066\u3099\u3059\u3002<\/p>\n<p>&nbsp;<\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h2>\n<p>\u3053\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u306f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr15_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h2>\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0<\/h2>\n<p>\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr15_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n","protected":false},"author":988,"featured_media":2294,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":{"0":"post-183","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-qpcr","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f\" \/>\n<meta property=\"og:description\" content=\"\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2015-11-19T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-04-17T06:12:28+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f\",\"datePublished\":\"2015-11-19T00:00:00+00:00\",\"dateModified\":\"2025-04-17T06:12:28+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/\"},\"wordCount\":149,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-faq-title-1.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/\",\"name\":\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-faq-title-1.jpg\",\"datePublished\":\"2015-11-19T00:00:00+00:00\",\"dateModified\":\"2025-04-17T06:12:28+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-faq-title-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-faq-title-1.jpg\",\"width\":1200,\"height\":630,\"caption\":\"qpcr-faq-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-faq\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f","og_description":"\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2015-11-19T00:00:00+00:00","article_modified_time":"2025-04-17T06:12:28+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f","datePublished":"2015-11-19T00:00:00+00:00","dateModified":"2025-04-17T06:12:28+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/"},"wordCount":149,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/","name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1.jpg","datePublished":"2015-11-19T00:00:00+00:00","dateModified":"2025-04-17T06:12:28+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1.jpg","width":1200,"height":630,"caption":"qpcr-faq-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-faq\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306b\u3064\u3044\u3066\u306e\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":183,"position":0},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":23665,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25064\/","url_meta":{"origin":183,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u306e\u30a2\u30cb\u30fc\u30ea\u30f3\u30b0\u6e29\u5ea6\u3092\u601d\u3044\u5207\u308a\u632f\u3063\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670828\u65e5","format":false,"excerpt":"\u65b0\u305f\u306aPCR\u691c\u51fa\u7cfb\u3092\u69cb\u7bc9\u3059\u308b\u5834\u5408\u3001\u4f55\u3088\u308a\u3082\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u914d\u5217\u304c\u91cd\u8981\u3068\u3044\u3046\u3053\u3068\u306f\u591a\u304f\u306e\u65b9\u304c\u8a8d\u8b58\u3057\u3066\u3044\u308b\u306e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25064_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23370,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pcr-dna-gsd-ts-tr-25061\/","url_meta":{"origin":183,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011PCR\u5f8c\u306e\u4fdd\u5b58\u6e29\u5ea6\u306f4\u2103\u4e00\u629e\u3067\u3059\u304b\uff1f\u4ed6\u306e\u6e29\u5ea6\u3082\u8a66\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7410\u670816\u65e5","format":false,"excerpt":"PCR\uff08\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u9023\u9396\u53cd\u5fdc\uff09\u306f\u3001\u5206\u5b50\u751f\u7269\u5b66\u306e\u5b9f\u9a13\u306e\u6839\u5e79\u3092\u306a\u3059\u975e\u5e38\u306b\u91cd\u8981\u306a\u6280\u8853\u3067\u3059\u3002PCR\u3092\u884c\u3063\u305f\u5f8c\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/pcr-dna-gsd-ts-tr-25061_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":183,"position":3},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":183,"position":4},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":183,"position":5},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-faq-title-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/183","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=183"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/183\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2294"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=183"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=183"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=183"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=183"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}