{"id":18351,"date":"2024-10-31T15:57:45","date_gmt":"2024-10-31T06:57:45","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=18351"},"modified":"2026-06-29T17:25:01","modified_gmt":"2026-06-29T08:25:01","slug":"nucleic-acid-purification-1-bid-ts-mbr-24072","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/","title":{"rendered":"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d"},"content":{"rendered":"\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-ad2f72ca wp-block-group-is-layout-flex\">\n<p>\u66f4\u65b0\u65e5 :<\/p>\n\n\n<div class=\"wp-block-post-date__modified-date wp-block-post-date\"><time datetime=\"2026-06-29T17:25:01+09:00\">6.29.2026<\/time><\/div><\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-intro-summary\">\n<p>\u3053\u306e\u8a18\u4e8b\u306e\u8981\u70b9<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u7d30\u80de\u58c1\u306e\u7269\u7406\u7684\u7834\u7815\u3068\u754c\u9762\u6d3b\u6027\u5264\u306b\u3088\u308b\u7d30\u80de\u819c\u30fb\u6838\u819c\u306e\u5316\u5b66\u7684\u7834\u58ca\u306b\u3088\u3063\u3066DNA\u3092\u7d30\u80de\u5916\u3078\u653e\u51fa\u3059\u308b\u5b9f\u9a13\u306b\u3064\u3044\u3066\u306e\u8a18\u4e8b\u3067\u3042\u308b\u3002<\/li>\n\n\n\n<li>\u62bd\u51fa\u6db2\u4e2d\u306e\u5869\u306fDNA\u3092\u6eb6\u3051\u305f\u72b6\u614b\u306b\u3057\u3001\u308d\u904e\u306b\u3088\u3063\u3066\u56fa\u5f62\u6210\u5206\u3092\u9664\u53bb\u3057\u3066DNA\u3092\u542b\u3080\u6db2\u4f53\u3092\u56de\u53ce\u3059\u308b\u3002<\/li>\n\n\n\n<li>\u51b7\u5374\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u308b\u3068DNA\u306e\u6eb6\u89e3\u5ea6\u304c\u4f4e\u4e0b\u3057\u3066\u6790\u51fa\u3057\u3001\u767d\u8272\u306e\u7cf8\u72b6\u7269\u3068\u3057\u3066\u89b3\u5bdf\u3067\u304d\u308b\u3002<\/li>\n\n\n\n<li>DNA\u306f\u5f37\u3044\u652a\u62cc\u3067\u5207\u65ad\u3055\u308c\u3084\u3059\u304f\u3001\u5404\u5de5\u7a0b\u306e\u539f\u7406\u7406\u89e3\u306f\u62bd\u51fa\u6210\u529f\u6761\u4ef6\u306e\u8a55\u4fa1\u3084DNA\u62bd\u51fa\u6cd5\u306e\u57fa\u790e\u7406\u89e3\u306b\u5f79\u7acb\u3064\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n<style>.wp-block-kadence-spacer.kt-block-spacer-18351_824ac7-8e .kt-block-spacer{height:20px;}.wp-block-kadence-spacer.kt-block-spacer-18351_824ac7-8e .kt-divider{border-top-width:1px;height:1px;border-top-color:#000000;width:100%;border-top-style:solid;}<\/style>\n<div class=\"wp-block-kadence-spacer aligncenter kt-block-spacer-18351_824ac7-8e\"><div class=\"kt-block-spacer kt-block-spacer-halign-center\"><hr class=\"kt-divider\" \/><\/div><\/div>\n\n\n\n<p>\u203b\u81ea\u7531\u7814\u7a76\u30c6\u30fc\u30de\u3092\u63a2\u3057\u3066\u3044\u308b\u304a\u7236\u3055\u3093\u304a\u6bcd\u3055\u3093\u3078<br>\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306f\u3001\u304a\u3046\u3061\u6642\u9593\u3067\u306e\u79d1\u5b66\u5b66\u7fd2\u3092\u5fdc\u63f4\u3057\u3066\u3044\u307e\u3059\uff01<br>\u300cDNA\u62bd\u51fa\u300d\u306f\u3001\u81ea\u7531\u7814\u7a76\u306e\u5b9a\u756a\u5b9f\u9a13\u306e\u3072\u3068\u3064\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"235\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/9a7dcd1b9610b93806402780b0639c6f.jpg\" alt=\"\" class=\"wp-image-18437\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/9a7dcd1b9610b93806402780b0639c6f.jpg 1000w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/9a7dcd1b9610b93806402780b0639c6f-300x71.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/9a7dcd1b9610b93806402780b0639c6f-768x180.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p><br>\u3057\u304b\u3057\u3001\u5b9a\u756a\u3060\u3068\u8ab0\u304b\u3068\u88ab\u3063\u3066\u3057\u307e\u3046\u306e\u3067\u306f\u3068\u5fc3\u914d\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u5b9f\u9a13\u3092\u3057\u306a\u304c\u3089\u300c\u306a\u305c\u3053\u3046\u306a\u308b\u3093\u3060\u308d\u3046\u300d\u300c\u3053\u308c\u3063\u3066\u4f55\u3060\u308d\u3046\u300d\u3068\u60f3\u50cf\u3092\u81a8\u3089\u307e\u305b\u305f\u308a\u3001\u8abf\u3079\u305f\u308a\u3001\u8ffd\u52a0\u306e\u5b9f\u9a13\u3092\u3057\u305f\u308a\u3059\u308b\u3053\u3068\u3067\u3001\u540c\u3058\u30c6\u30fc\u30de\u3092\u9078\u3093\u3067\u3082\u3001\u300c\u307b\u304b\u306e\u4eba\u3068\u306f\u307e\u3063\u305f\u304f\u9055\u3046\u81ea\u7531\u7814\u7a76\u300d\u3092\u5b8c\u6210\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u304b\u3089\u3067\u3059\u3002<br>\u3067\u306f\u3001\u300cDNA\u62bd\u51fa\u300d\u306e\u65b9\u6cd5\u3068\u3001\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d\u3092\u8003\u3048\u3066\u3044\u304d\u307e\u3057\u3087\u3046\uff01<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30a4\u30c1\u30b4\u304b\u3089dna\u3092\u62bd\u51fa\u3057\u3066\u307f\u3088\u3046\">\u30a4\u30c1\u30b4\u304b\u3089DNA\u3092\u62bd\u51fa\u3057\u3066\u307f\u3088\u3046\uff01<\/h2>\n\n\n\n<p>\u30a4\u30c1\u30b4\u306e\u5165\u624b\u304c\u96e3\u3057\u3044\u5834\u5408\u306f\u3001\u30d6\u30ed\u30c3\u30b3\u30ea\u30fc\u3067\u3082\u4ee3\u7528\u304c\u3067\u304d\u307e\u3059\u3002\u307b\u304b\u306b\u3082DNA\u3092\u62bd\u51fa\u3057\u3084\u3059\u3044\u6750\u6599\u304c\u3042\u308b\u304b\u3082\u77e5\u308c\u307e\u305b\u3093\u3002\u305c\u3072\u304a\u5b50\u3055\u3093\u3068\u4e00\u7dd2\u306b\u63a2\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p>\u7528\u610f\u3059\u308b\u3082\u306e<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30a4\u30c1\u30b4\uff08\u30d8\u30bf\u3092\u53d6\u3063\u305f\u3082\u306e\uff09<\/li>\n\n\n\n<li>\u4e2d\u6027\u6d17\u5264<sup>\u203b1<\/sup><br>\u203b1\uff1a\u591a\u304f\u306e\u4e2d\u6027\u6d17\u5264\u306f\u3001\u6db2\u6027\u306e\u3068\u3053\u308d\u306b\u300c\u4e2d\u6027\u300d\u3068\u66f8\u3044\u3066\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u98df\u5869<\/li>\n\n\n\n<li>\u51b7\u8535\u5eab\u3067\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u3000\u7d14\u5ea6\u306e\u9ad8\u3044\u300c\u7121\u6c34\u30a8\u30bf\u30ce\u30fc\u30eb\u300d<sup>\u203b2<\/sup>\u3092\u6e96\u5099\u3057\u307e\u3057\u3087\u3046\u3002<br>\u203b2\uff1a\u85ac\u5c40\u3067\u8cfc\u5165\u3067\u304d\u307e\u3059\u304c\u3001\u300c\u6d88\u6bd2\u7528\u30a8\u30bf\u30ce\u30fc\u30eb\u300d\u3057\u304b\u8ca9\u58f2\u3057\u3066\u3044\u306a\u3044\u304a\u5e97\u3082\u3042\u308a\u307e\u3059\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002<\/li>\n\n\n\n<li>\u30b9\u30dd\u30a4\u30c8\uff081 mL\u304c\u91cf\u308c\u308b\u3082\u306e\uff09\u3000\u203b100\u5747\u3084\u7fd2\u5b57\u7528\u5177\u54c1\u3068\u3057\u3066\u3088\u304f\u8ca9\u58f2\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u8a08\u91cf\u30b9\u30d7\u30fc\u30f3\uff08\u5927\u3055\u3058\u3001\u5c0f\u3055\u3058\uff09<\/li>\n\n\n\n<li>\u8a08\u91cf\u30ab\u30c3\u30d7<\/li>\n\n\n\n<li>\u30c1\u30e3\u30c3\u30af\u4ed8\u30dd\u30ea\u888b<\/li>\n\n\n\n<li>\u30da\u30fc\u30d1\u30fc\u30bf\u30aa\u30eb<\/li>\n\n\n\n<li>\u900f\u660e\u306a\u30b3\u30c3\u30d7<\/li>\n\n\n\n<li>\u8336\u3053\u3057<\/li>\n\n\n\n<li>\u5272\u308a\u3070\u3057<\/li>\n<\/ul>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 3px solid red;border-radius: 10px\"><b>\u5b9f\u9a13\u4e0a\u306e\u6ce8\u610f\uff08\u4fdd\u8b77\u8005\u306e\u65b9\u3078\uff09<\/b><br>\u30fb\u5bfe\u8c61\u5e74\u9f62\u306f5\u6b73\u4ee5\u4e0a\u3067\u3059\u3002\u5c0f\u5b66\u751f\u4ee5\u4e0b\u306e\u304a\u5b50\u3055\u3093\u304c\u5b9f\u9a13\u3092\u8a66\u3059\u5834\u5408\u306f\u3001\u5fc5\u305a\u3054\u4e00\u7dd2\u306b\u304a\u9858\u3044\u3057\u307e\u3059\u3002<br>\u30fb\u5b9f\u9a13\u3092\u884c\u3046\u969b\u306f\u3001\u5fc5\u305a\u624b\u9806\u3092\u78ba\u304b\u3081\u3066\u304b\u3089\u5b9f\u65bd\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br>\u30fb\u6750\u6599\uff08\u6eb6\u6db2\u3001\u306f\u3055\u307f\u3001\u5668\u5177\u306a\u3069\uff09\u306e\u53d6\u308a\u6271\u3044\u306b\u5341\u5206\u306b\u6ce8\u610f\u3057\u3001\u30b1\u30ac\u306e\u306a\u3044\u3088\u3046\u306b\u3001\u500b\u4eba\u306e\u8cac\u4efb\u3067\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002<br>\u30fb\u5b9f\u9a13\u3067\u4f5c\u3063\u305f\u3082\u306e\u3084\u4f7f\u3063\u305f\u3082\u306e\u306f\u98f2\u3093\u3060\u308a\u98df\u3079\u305f\u308a\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002<br>\u30fb\u30a8\u30bf\u30ce\u30fc\u30eb\u306f\u706b\u6c17\u53b3\u7981\u3067\u3059\u3002\u706b\u306e\u8fd1\u304f\u3067\u5b9f\u9a13\u3092\u3057\u306a\u3044\u3088\u3046\u306b\u3057\u307e\u3057\u3087\u3046\u3002<br>\u30fb\u6750\u6599\u3084\u74b0\u5883\u306b\u3088\u3063\u3066\u306f\u8a18\u4e8b\u901a\u308a\u306e\u7d50\u679c\u306b\u306a\u3089\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/div>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5b9f\u9a13\u65b9\u6cd5\">\u5b9f\u9a13\u65b9\u6cd5<\/h3>\n\n\n\n<p>1. DNA\u62bd\u51fa\u6db2\u3092\u4f5c\u308a\u307e\u3059\u3002<br>\u6c3450 mL\u3092\u8a08\u91cf\u30ab\u30c3\u30d7\u3067\u91cf\u308a\u3001\u3053\u308c\u306b\u98df\u5668\u7528\u6d17\u52641 mL\u3068\u98df\u586910 g\uff08\u5c0f\u3055\u30582\u676f\uff09\u3092\u5165\u308c\u3066\u3001\u3086\u3063\u304f\u308a\u3068\u6df7\u305c\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\">Q. \u62bd\u51fa\u6db2\u306b\u306a\u305c\u6d17\u5264\u3068\u5869\u3092\u5165\u308c\u308b\u306e\uff1f<br>A. \u307e\u305a\u3001\u6d17\u5264\u306b\u306f\u300c\u754c\u9762\u6d3b\u6027\u5264\uff08\u304b\u3044\u3081\u3093\u304b\u3063\u305b\u3044\u3056\u3044\uff09\u300d\u3068\u3044\u3046\u7269\u8cea\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<br>DNA\u306f\u7d30\u80de\u306e\u5965\u6df1\u304f\u306b\u3057\u307e\u308f\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u305d\u308c\u3092\u53d6\u308a\u51fa\u3059\u305f\u3081\u306b\u306f\u3001\u7d30\u80de\u3084\u6838\u306e\u819c\u3092\u58ca\u3055\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u305d\u308c\u3092\u58ca\u3059\u305f\u3081\u306b\u300c\u754c\u9762\u6d3b\u6027\u5264\u300d\u304c\u52b9\u679c\u7684\u3060\u304b\u3089\u3067\u3059\u3002<br>\u307e\u305f\u3001\u5869\u3092\u5165\u308c\u308b\u7406\u7531\u306f\u3001DNA\u304c\u5869\u3092\u542b\u3080\u6db2\u4f53\u306b\u6eb6\u3051\u3084\u3059\u3044\u6027\u8cea\u3092\u6301\u3063\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002<br><figure class=\"wp-block-image aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"213\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/cee11ccf7bcea45e0c40f52c1abaf93b-300x213.jpg\" alt=\"\" class=\"wp-image-18405\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/cee11ccf7bcea45e0c40f52c1abaf93b-300x213.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/cee11ccf7bcea45e0c40f52c1abaf93b-1024x727.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/cee11ccf7bcea45e0c40f52c1abaf93b-768x546.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/cee11ccf7bcea45e0c40f52c1abaf93b-1536x1091.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/cee11ccf7bcea45e0c40f52c1abaf93b-2048x1455.jpg 2048w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure><\/div>\n\n\n\n<p>2. \u30c1\u30e3\u30c3\u30af\u4ed8\u30dd\u30ea\u888b\u306e\u4e2d\u306b\u3001\u30d8\u30bf\u3092\u53d6\u3063\u305f\u30a4\u30c1\u30b4\u3092\u5165\u308c\u3001\u30c1\u30e3\u30c3\u30af\u3092\u9589\u3081\u307e\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/73ef4d0715fbdcc4540b764bc712c664.jpg\" alt=\"\" width=\"182\" height=\"239\">\u2003\u21d2\u2003<img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/e723f249d01a822602ba388581c15a44.jpg\" alt=\"\" width=\"447\" height=\"148\"><br>\u203b\u30dd\u30ea\u888b\u306e\u30c1\u30e3\u30c3\u30af\u306f\u3001\u4e2d\u8eab\u304c\u3053\u307c\u308c\u306a\u3044\u3088\u3046\u306b\u3057\u3063\u304b\u308a\u9589\u3081\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p>3. \u30dd\u30ea\u888b\u306e\u4e0a\u304b\u3089\u30a4\u30c1\u30b4\u3092\u62bc\u3057\u3064\u3076\u3057\u307e\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/1f34df0316029438eb46d609f3ba47ac.jpg\" alt=\"\" width=\"436\" height=\"199\"><br>\u6307\u306e\u8179\u3067\u3001\u4e0a\u304b\u3089\u3057\u3063\u304b\u308a\u3064\u3076\u3057\u307e\u3057\u3087\u3046\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/2972ae211d4843b2965bbd44c317fc34.jpg\" alt=\"\" width=\"339\" height=\"220\"><\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\">Q. \u306a\u305c\u30a4\u30c1\u30b4\u3092\u3064\u3076\u3055\u306a\u3044\u3068\u3044\u3051\u306a\u3044\u306e\uff1f<br>A. \u7d30\u80de\u58c1\u3092\u58ca\u3059\u305f\u3081\u3067\u3059\u3002DNA\u3092\u53d6\u308a\u51fa\u3059\u306b\u306f\u3001\u7d30\u80de\u58c1\u3001\u7d30\u80de\u819c\u3001\u6838\u819c\u3092\u7a81\u7834\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u3053\u3053\u3067\u7d30\u80de\u58c1\u3092\u58ca\u3057\u3001\u4e2d\u306eDNA\u3092\u53d6\u308a\u51fa\u3057\u3084\u3059\u304f\u3059\u308b\u6e96\u5099\u3092\u3057\u3066\u3044\u307e\u3059\u3002<\/div>\n\n\n\n<p>4. \u62bd\u51fa\u6db210 mL\uff08\u5c0f\u3055\u30582\u676f\uff09\u3092\u3001\u30c1\u30e3\u30c3\u30af\u4ed8\u304d\u30dd\u30ea\u888b\u306b\u5165\u308c\u307e\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/b03967706c4438bd1b5f13da06590abb.jpg\" alt=\"\" width=\"559\" height=\"262\"><\/p>\n\n\n\n<p>5. \u30c1\u30e3\u30c3\u30af\u4ed8\u304d\u30dd\u30ea\u888b\u306e\u30c1\u30e3\u30c3\u30af\u3092\u3057\u3001\u30dd\u30ea\u888b\u306e\u4e0a\u304b\u3089\u3084\u3055\u3057\u304f\u62bc\u3057\u3066\u6df7\u305c\u307e\u3059\u3002\u6fc0\u3057\u304f\u62bc\u3057\u3064\u3076\u3055\u306a\u3044\u3088\u3046\u306b\u6ce8\u610f\u3057\u307e\u3057\u3087\u3046\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/698292e1792417899fbc5d3a38b74cf8.jpg\" alt=\"\" width=\"595\" height=\"219\"><\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\">Q. \u306a\u305c\u6fc0\u3057\u304f\u62bc\u3057\u3064\u3076\u3057\u305f\u3089\u3044\u3051\u306a\u3044\u306e\uff1f<br>A. DNA\u306f\u3082\u308d\u3044\u305f\u3081\u3001\u6fc0\u3057\u304f\u62bc\u3057\u3064\u3076\u3057\u305f\u308a\u5f37\u304f\u304b\u304d\u6df7\u305c\u3066\u3057\u307e\u3046\u3068\u3001\u77ed\u304f\u5207\u308c\u3066\u3057\u307e\u3044\u3001\u5272\u308a\u3070\u3057\u3067\u53d6\u308c\u306a\u304f\u306a\u3063\u3066\u3057\u307e\u3046\u304b\u3089\u3067\u3059\u3002<\/div>\n\n\n\n<p>6. \u30a4\u30c1\u30b4\u304c\u6db2\u72b6\u306b\u306a\u3063\u305f\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/58f3162543dd3e7247b495e99f79356b.jpg\" alt=\"\" width=\"587\" height=\"180\"><\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\"><p>Q. \u3053\u306e\u3068\u304d\u3001\u30dd\u30ea\u888b\u306e\u4e2d\u3067\u4f55\u304c\u8d77\u3053\u3063\u3066\u308b\u306e\uff1f<br>A. \u7d30\u80de\u58c1\u3001\u7d30\u80de\u819c\u3001\u6838\u819c\u304c\u3001\u7269\u7406\u7684\u306a\u7834\u7815\u3068\u62bd\u51fa\u6db2\u306b\u3088\u308a\u58ca\u3055\u308c\u305f\u72b6\u614b\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u8d64\u3044\u6db2\u4f53\u306e\u4e2d\u306b\u3001DNA\u304c\u62bd\u51fa\u3055\u308c\u305f\u72b6\u614b\u3067\u3059\u3002<\/p>\n<p>Q. \u3069\u3046\u3057\u3066\u7d30\u80de\u58c1\u3084\u7d30\u80de\u819c\u3084\u6838\u819c\u304c\u58ca\u308c\u305f\u306e\uff1f<br>A. \u4e3b\u306b\u3001\u7d30\u80de\u58c1\u306f\u300c\u3064\u3076\u3057\u305f\u3053\u3068\u300d\u3001\u7d30\u80de\u819c\u3084\u6838\u819c\u306f\u300c\u62bd\u51fa\u6db2\u306b\u89e6\u308c\u305f\u3053\u3068\u300d\u3067\u58ca\u308c\u307e\u3057\u305f\u3002\u3064\u3076\u3059\u3053\u3068\u3067\u7269\u304c\u58ca\u308c\u308b\u306e\u306f\u308f\u304b\u308a\u307e\u3059\u3088\u306d\u3002\u7d30\u80de\u58c1\u304c\u58ca\u308c\u305f\u306e\u3082\u3001\u540c\u3058\u30a4\u30e1\u30fc\u30b8\u3067\u3059\u3002\u7d30\u80de\u819c\u3084\u6838\u819c\u304c\u62bd\u51fa\u6db2\u3067\u58ca\u308c\u305f\u306e\u306f\u3001\u62bd\u51fa\u6db2\u306b\u52a0\u3048\u305f\u6d17\u5264\u306b\u306f\u3001\u300c\u754c\u9762\u6d3b\u6027\u5264\u300d\u3068\u3044\u3046\u3001\u7d30\u80de\u819c\u3084\u6838\u306e\u819c\u3092\u58ca\u3059\u7269\u8cea\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002<\/p>\n<p>Q. DNA\u306f\u307e\u3060\u898b\u3048\u306a\u3044\u306e\uff1f<br>A. \u306f\u3044\u3001\u307e\u3060\u898b\u3048\u307e\u305b\u3093\u3002\u3053\u308c\u306f\u3001\u62bd\u51fa\u6db2\u306b\u542b\u307e\u308c\u308b\u300c\u5869\u300d\u306b\u3088\u308aDNA\u304c\u6eb6\u3051\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002<br>\u7d05\u8336\u306b\u7802\u7cd6\u3092\u5165\u308c\u308b\u3068\u3001\u6eb6\u3051\u3066\u898b\u3048\u306a\u304f\u306a\u308b\u306e\u3068\u540c\u3058\u3067\u3059\u3002<br>\u3069\u3046\u3057\u3066DNA\u3092\u6eb6\u304b\u3059\u306e\u304b\u3068\u3044\u3046\u3068\u3001\u3053\u306e\u3042\u3068\u3001\u30a4\u30c1\u30b4\u306e\u56fa\u4f53\u90e8\u5206\u3092\u308d\u904e\u3057\u3066\u9664\u304f\u304b\u3089\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001DNA\u3092\u6eb6\u3051\u305f\u72b6\u614b\u306b\u3057\u3066\u304a\u304b\u306a\u3044\u3068\u3001\u4e00\u7dd2\u306b\u9664\u304b\u308c\u3066\u3057\u307e\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p>7. \u30ad\u30c3\u30c1\u30f3\u30da\u30fc\u30d1\u30fc\u3092\u7528\u610f\u3057\u3001\u6298\u308a\u7d19\u306e\u3088\u3046\u306b\u4e09\u89d2\u306b2\u56de\u6298\u3063\u3066\u304f\u3060\u3055\u3044\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/8453b5f0733b904c927a448bc4c4a545.jpg\" alt=\"\" width=\"522\" height=\"280\"><\/p>\n\n\n\n<p>8. \u8336\u3053\u3057\u3068\u900f\u660e\u306a\u30b3\u30c3\u30d7\u3092\u7528\u610f\u3057\u3001\u30b3\u30c3\u30d7\u306e\u4e0a\u306b\u8336\u3053\u3057\u3092\u8f09\u305b\u307e\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/2aad1c7039b0c4497bf44fd76134c825-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\"><\/p>\n\n\n\n<p>9. \u6298\u3063\u305f\u30ad\u30c3\u30c1\u30f3\u30da\u30fc\u30d1\u30fc\u3092\u3001\u8336\u3053\u3057\u306e\u4e0a\u306b\u306e\u305b\u307e\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/d7c9c305a7bc0191e57a60c75bd1c0e3.jpg\" alt=\"\" width=\"328\" height=\"333\"> \u3000<\/p>\n\n\n\n<p>10. \u30c1\u30e3\u30c3\u30af\u4ed8\u304d\u30dd\u30ea\u888b\u306e\u4e2d\u8eab\u3092\u3001\u30ad\u30c3\u30c1\u30f3\u30da\u30fc\u30d1\u30fc\u306e\u4e0a\u306b\u5165\u308c\u307e\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/213f5f0a44459eedf84a6001b55015c1.jpg\" alt=\"\" width=\"594\" height=\"198\"><\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\">Q. \u3053\u306e\u4f5c\u696d\u3001\u4f55\u306e\u305f\u3081\u306b\u3057\u3066\u3044\u308b\u306e\uff1f<br>A. \u56fa\u4f53\u3092\u9664\u304d\u3001DNA\u3092\u542b\u3080\u6db2\u4f53\u3060\u3051\u306b\u3059\u308b\u305f\u3081\u306b\u300c\u308d\u904e\u300d\u3092\u884c\u3063\u3066\u3044\u308b\u306e\u304c\u3001\u3053\u306e\u4f5c\u696d\u3067\u3059\u3002<br>\u3053\u306e\u3068\u304d\u3001\u30da\u30fc\u30d1\u30fc\u30d5\u30a3\u30eb\u30bf\u30fc\u3067\u9664\u304b\u308c\u308b\u56fa\u4f53\u306b\u306f\u3001\u58ca\u308c\u305f\u7d30\u80de\u58c1\u3084\u7d30\u80de\u819c\u3084\u6838\u819c\u306a\u3069\u306e\u96d1\u591a\u306a\u3082\u306e\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002DNA\u3092\u62bd\u51fa\u3059\u308b\u306b\u306f\u3001\u3067\u304d\u308b\u304b\u304e\u308a\u4f59\u8a08\u306a\u3082\u306e\u3092\u542b\u307e\u306a\u3044\u72b6\u614b\u3092\u4f5c\u308a\u51fa\u3059\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/div>\n\n\n\n<p>11.\u6db2\u304c\u8336\u3053\u3057\u304b\u3089\u4e0b\u306e\u30b3\u30c3\u30d7\u3078\u3068\u3001\u5c11\u3057\u305a\u3064\u843d\u3061\u3066\u3044\u304d\u307e\u3059\u3002\u6db2\u304c\u843d\u3061\u3066\u3053\u306a\u304f\u306a\u3063\u305f\u3089\u3001\u4e0a\u306e\u8336\u3053\u3057\u3068\u30ad\u30c3\u30c1\u30f3\u30da\u30fc\u30d1\u30fc\u3092\u53d6\u308a\u5916\u3057\u307e\u3057\u3087\u3046\u3002\u4e0b\u306e\u5199\u771f\u306e\u3088\u3046\u306b\u3001\u8d64\u3044\u6db2\u304c\u30b3\u30c3\u30d7\u306b\u6e9c\u307e\u3063\u3066\u3044\u308b\u306f\u305a\u3067\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/385a6f10fa7ec42f402fb3fe20930e6c.jpg\" alt=\"\" width=\"246\" height=\"285\"><br>\u3053\u306e\u6db2\u4f53\u306e\u4e2d\u306b\u3001DNA\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u307e\u3060\u898b\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p>12. \u51b7\u8535\u5eab\u3067\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u309210 mL\uff08\u5c0f\u3055\u30582\u676f\uff09\u52a0\u3048\u307e\u3059\u3002<br>\u6db2\u304c\u306f\u306d\u306a\u3044\u3088\u3046\u306b\u3001\u30b3\u30c3\u30d7\u3092\u659c\u3081\u306b\u3057\u3066\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u304c\u58c1\u3092\u4f1d\u3046\u3088\u3046\u306b\u9759\u304b\u306b\u5165\u308c\u3066\u304f\u3060\u3055\u3044\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/fa2aa2ecdc84943faec5ba0bf7fd1e2c.jpg\" alt=\"\" width=\"405\" height=\"287\"><\/p>\n\n\n\n<p>\u305d\u3046\u3059\u308b\u3068\u3001\u4e0a\u306e\u900f\u660e\u306a\u5c64\u3068\u4e0b\u306e\u8d64\u3044\u5c64\u30012\u3064\u306e\u5c64\u304c\u3067\u304d\u3042\u304c\u308a\u307e\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/5c8c0e32df70045ad341f90367af5c59.jpg\" alt=\"\" width=\"285\" height=\"361\"><\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\">Q. \u3069\u3046\u3057\u30662\u5c64\u306b\u5206\u304b\u308c\u308b\u306e\uff1f<br>A. \u307e\u305a\u3001\u4e0a\u306e\u900f\u660e\u306a\u5c64\u306f\u30a8\u30bf\u30ce\u30fc\u30eb\u3067\u3001\u4e0b\u306e\u8d64\u3044\u5c64\u306e\u4e3b\u306a\u6210\u5206\u306f\u6c34\u3067\u3059\u30022\u5c64\u306b\u5206\u304b\u308c\u308b\u306e\u306f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3088\u308a\u91cd\u3044\u6c34\u304c\u4e0b\u306b\u6e9c\u307e\u308b\u304b\u3089\u3067\u3059\u3002\u30ac\u30e0\u30b7\u30ed\u30c3\u30d7\u3092\u30a2\u30a4\u30b9\u30c6\u30a3\u30fc\u306b\u5165\u308c\u308b\u3068\u3001\u30ac\u30e0\u30b7\u30ed\u30c3\u30d7\u306e\u65b9\u304c\u91cd\u3044\u304b\u3089\u5e95\u306b\u6e9c\u307e\u308b\u306e\u3068\u540c\u3058\u539f\u7406\u3067\u3059\u306d\u3002\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u9759\u304b\u306b\u5165\u308c\u308b\u3053\u3068\u3067\u3001\u6c34\u306e\u5c64\u3068\u6df7\u3058\u3089\u305a\u3001DNA\u304c\u62bd\u51fa\u3055\u308c\u3084\u3059\u3044\u72b6\u6cc1\u3092\u4f5c\u308a\u307e\u3059\u3002<\/div>\n\n\n\n<p>\u3053\u306e2\u3064\u306e\u5c64\u306e\u5883\u76ee\u3092\u3088\u304f\u898b\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<br>\u7dbf\u3042\u3081\u306e\u3088\u3046\u306a\u767d\u3044\u3075\u308f\u3075\u308f\u3057\u305f\u3082\u306e\u304c\u3067\u304d\u3066\u3044\u308b\u3067\u3057\u3087\u3046\u304b\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/4f5c7b49552c20fca37cc41c78cadac5.jpg\" alt=\"\" width=\"551\" height=\"259\"><br>\u3053\u306e\u767d\u304f\u3075\u308f\u3075\u308f\u3057\u305f\u3082\u306e\u304c\u3001DNA\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\">Q. \u3069\u3046\u3057\u3066\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u5165\u308c\u305f\u3089DNA\u304c\u73fe\u308c\u305f\u306e\uff1f<br>A. DNA\u306f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u4e2d\u3067\u6eb6\u89e3\u5ea6\u304c\u4e0b\u304c\u308b\u304b\u3089\u3067\u3059\u3002\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u5165\u308c\u308b\u524d\u3001DNA\u306f\u6db2\u4f53\u306e\u4e2d\u3067\u6eb6\u3051\u3066\u3044\u3066\u3001\u76ee\u306b\u306f\u898b\u3048\u306a\u3044\u72b6\u614b\u3067\u3057\u305f\u3002<br>\u3057\u304b\u3057\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u52a0\u3048\u308b\u3053\u3068\u3067\u3001DNA\u306f\u6eb6\u3051\u305f\u307e\u307e\u3067\u3044\u3089\u308c\u306a\u304f\u306a\u308a\u3001\u56fa\u4f53\u306b\u306a\u3063\u3066\u73fe\u308c\u305f\u306e\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001\u6eb6\u3051\u3066\u3044\u305f\u7269\u8cea\u304c\u56fa\u4f53\u3068\u306a\u3063\u3066\u73fe\u308c\u308b\u3053\u3068\u3092\u6790\u51fa\uff08\u305b\u304d\u3057\u3085\u3064\uff09\u3068\u8a00\u3044\u307e\u3059\u3002<br>\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u4f7f\u3063\u305f\u306e\u306f\u3001\u5ba4\u6e29\u3088\u308a\u3082\u51b7\u305f\u3044\u65b9\u304cDNA\u3092\u6790\u51fa\u3055\u305b\u308b\u52b9\u679c\u304c\u9ad8\u3044\u305f\u3081\u3067\u3059\u3002\u3053\u308c\u306f\u3001\u7802\u7cd6\u306f\u304a\u6e6f\u306b\u6eb6\u3051\u3084\u3059\u3044\u3051\u308c\u3069\u3001\u6c34\u306b\u306f\u306a\u304b\u306a\u304b\u6eb6\u3051\u306a\u3044\u306e\u3068\u540c\u3058\u3067\u3001\u51b7\u305f\u3044\u65b9\u304c\u300c\u8272\u3005\u306a\u3082\u306e\u3092\u6eb6\u304b\u3059\u529b\u300d\u304c\u4f4e\u3044\u305f\u3081\u3067\u3059\u3002<\/div>\n\n\n\n<p>13. 2\u5c64\u306e\u5883\u76ee\u306e\u3042\u305f\u308a\u306b\u6d6e\u3044\u305f\u767d\u3044\u7cf8\u72b6\u306eDNA\u3092\u3001\u5272\u308a\u3070\u3057\u3067\u3086\u3063\u304f\u308a\u6df7\u305c\u308b\u3088\u3046\u306b\u3059\u304f\u3044\u53d6\u308a\u307e\u3059\u3002DNA\u306f\u3082\u308d\u3044\u306e\u3067\u3001\u6fc0\u3057\u304f\u6df7\u305c\u306a\u3044\u3088\u3046\u306b\u6ce8\u610f\u3057\u307e\u3057\u3087\u3046\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/976b35ca14d9881d0abbf9c0c2b074f6.jpg\" alt=\"\" width=\"239\" height=\"426\"><\/p>\n\n\n\n<p>14. \u3053\u306e\u767d\u3044\u3082\u306e\u304cDNA\u3067\u3059\u3002<br><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/fc978ef819e54e1d8e3950128cf92f9f.jpg\" alt=\"\" width=\"341\" height=\"270\"><br>DNA\u3092\u62bd\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\uff01<\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 1px dashed #136FFF;border-radius: 5px\"><p>Q. \u53d6\u308a\u51fa\u3057\u305f\u767d\u3044\u3082\u306e\u306f\u672c\u5f53\u306bDNA\u306a\u306e\uff1f<br>A. \u3053\u3053\u3067\u3054\u7d39\u4ecb\u3057\u305f\u306e\u306fDNA\u62bd\u51fa\u306b\u4e00\u822c\u7684\u306b\u4f7f\u308f\u308c\u3066\u3044\u308b\u624b\u9806\u306a\u306e\u3067\u3001\u3053\u306e\u767d\u3044\u3082\u306e\u306fDNA\u306e\u300c\u306f\u305a\u300d\u3068\u306f\u8a00\u3048\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u306e\u767d\u3044\u3082\u306e\u304c\u672c\u5f53\u306bDNA\u306a\u306e\u304b\u3092\u4eca\u306e\u72b6\u614b\u3067\u78ba\u304b\u3081\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u672c\u5f53\u306bDNA\u304b\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u3001\u8ffd\u52a0\u5b9f\u9a13\u304c\u5fc5\u8981\u3067\u3059\u3002<br>\u305f\u3068\u3048\u3070\u3001\u300cDNA\u3060\u3051\u3092\u67d3\u3081\u308b\u8a66\u85ac\u300d\u300cDNA\u3092\u67d3\u3081\u306a\u3044\u8a66\u85ac\u300d\u306e\u4e21\u65b9\u3092\u4f7f\u3046\u3053\u3068\u3067\u78ba\u8a8d\u304c\u3067\u304d\u307e\u3059\u3002DNA\u3060\u3051\u3092\u67d3\u3081\u308b\u8a66\u85ac\u306b\u306f\u3001\u9162\u9178\u30aa\u30eb\u30bb\u30a4\u30f3\u3001\u9162\u9178\u30ab\u30fc\u30df\u30f3\u306a\u3069\u304c\u3042\u308a\u3001\u3044\u305a\u308c\u3082DNA\u306f\u8d64\u304f\u67d3\u307e\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u98df\u7528\u8272\u7d20\uff08\u8d64\uff09\u306fDNA\u3092\u8d64\u304f\u67d3\u3081\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u9162\u9178\u30aa\u30eb\u30bb\u30a4\u30f3\u3084\u9162\u9178\u30ab\u30fc\u30df\u30f3\u3067\u8d64\u304f\u67d3\u307e\u308a\u3001\u98df\u7528\u8272\u7d20\uff08\u8d64\uff09\u3067\u67d3\u307e\u3089\u306a\u3051\u308c\u3070\u3001\u300c\u53d6\u308a\u51fa\u3057\u305f\u767d\u3044\u3082\u306e\u306fDNA\u3067\u3042\u308b\u300d\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n<p>Q. \u62bd\u51fa\u3057\u305fDNA\u3092\u9855\u5fae\u93e1\u3067\u898b\u305f\u3089\u3001\u3044\u308f\u3086\u308b\u300c\u3089\u305b\u3093\u69cb\u9020\u300d\u306f\u898b\u3048\u308b\uff1f<br>A. \u3044\u3044\u3048\u3002\u3054\u5bb6\u5ead\u3067\u5165\u624b\u53ef\u80fd\u306a\u5149\u5b66\u9855\u5fae\u93e1\u3067DNA\u306e\u3089\u305b\u3093\u69cb\u9020\u3092\u898b\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002<br>DNA\u306e\u3089\u305b\u3093\u69cb\u9020\u306e\u76f4\u5f84\u306f2 nm\uff082\u30ca\u30ce\u30e1\u30fc\u30c8\u30eb\u3001\u30ca\u30ce\u30e1\u30fc\u30c8\u30eb\u306f1 mm\u306e1\/1000000\u306e\u5927\u304d\u3055\uff09\u3067\u3001\u3068\u3066\u3082\u5c0f\u3055\u3044\u305f\u3081\u3067\u3059\u3002\u3053\u308c\u3092\u898b\u308b\u305f\u3081\u306b\u306f\u3001\u96fb\u5b50\u9855\u5fae\u93e1\u3068\u3044\u3046\u3001\u6570\u5341\u4e07\u304b\u3089\u6570\u767e\u4e07\u3082\u306e\u500d\u7387\u3067\u62e1\u5927\u3067\u304d\u308b\u9855\u5fae\u93e1\u304c\u5fc5\u8981\u3067\u3059\u3002<br><figure><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/9fe66541515d31eedc7a1fbe210c7631.jpg\" alt=\"\" width=\"205\" height=\"302\"><\/figure><\/p>\n<p>Q. \u53d6\u308a\u51fa\u3057\u305fDNA\u306f\u4f55\u306b\u4f7f\u3046\u306e\uff1f<br>A. \u75c5\u6c17\u306e\u539f\u56e0\u3092\u63a2\u3057\u51fa\u3057\u3066\u6cbb\u7642\u85ac\u3092\u958b\u767a\u3057\u305f\u308a\u3001\u72af\u7f6a\u635c\u67fb\u306e\u9451\u5b9a\u3084\u98df\u54c1\u306e\u5b89\u5168\u78ba\u8a8d\u306e\u305f\u3081\u306b\u5206\u6790\u3057\u305f\u308a\u3068\u3001\u3053\u3053\u3067\u306f\u66f8\u304d\u304d\u308c\u306a\u3044\u307b\u3069\u3055\u307e\u3056\u307e\u306a\u7528\u9014\u306b\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u5b9f\u9a13\u3092\u3054\u5bb6\u5ead\u3067\u884c\u3046\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u304c\u3001\u5b9f\u306f\u3053\u306eDNA\u62bd\u51fa\u6cd5\u306e\u539f\u7406\u3001\u5c02\u9580\u306e\u7814\u7a76\u8005\u304c\u65e5\u3005\u884c\u3063\u3066\u3044\u308b\u65b9\u6cd5\u306e\u4e00\u3064\u3067\u3082\u3042\u308b\u3093\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/11e957e51ccbdd1e8e0b2d9690e304e5-1-150x150.jpg\" alt=\"\" width=\"80\" height=\"80\">\u3000<b>\u3082\u3057\u3046\u307e\u304f\u62bd\u51fa\u3067\u304d\u306a\u304b\u3063\u305f\u3089\uff1f<\/b><\/p>\n\n\n\n<p>\u4ee5\u4e0b\u306e\u9805\u76ee\u3092\u518d\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u62bd\u51fa\u6db2\u3092\u6df7\u305c\u305f\u5f8c\u3001\u30a4\u30c1\u30b4\u3092\u6fc0\u3057\u304f\u62bc\u3057\u3064\u3076\u3057\u305f\u308a\u3001\u6df7\u305c\u305f\u308a\u3057\u3066\u3044\u306a\u3044\u304b\u3002<\/li>\n\n\n\n<li>\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u5165\u308c\u308b\u3068\u304d\u3001\u58c1\u3092\u4f1d\u308f\u305b\u3066\u3001\u3086\u3063\u304f\u308a\u5165\u308c\u3066\u3044\u308b\u304b\u3002<\/li>\n\n\n\n<li>\u30a4\u30c1\u30b4\u304c\u53e4\u304f\u306a\u3063\u3066\u3044\u305f\u308a\u3001\u5c0f\u3055\u3059\u304e\u305f\u308a\u3057\u3066\u3044\u306a\u3044\u304b\u3002<\/li>\n\n\n\n<li>\u5b9f\u9a13\u624b\u9806\u306b\u9593\u9055\u3044\u306a\u3044\u304b\u3002<\/li>\n\n\n\n<li>\u90e8\u5c4b\u304c\u6691\u3059\u304e\u306a\u3044\u304b\uff08\u6dbc\u3057\u3044\u90e8\u5c4b\u306e\u65b9\u304c\u6210\u529f\u3057\u3084\u3059\u3044\u3067\u3059\uff09\u3002<\/li>\n<\/ul>\n\n\n\n<p>\u5931\u6557\u304c\u3042\u308b\u304b\u3089\u3053\u305d\u81ea\u7531\u7814\u7a76\u3067\u3059\uff01\u8a66\u884c\u932f\u8aa4\u306e\u30c1\u30e3\u30f3\u30b9\u3067\u3059\u306e\u3067\u3001\u3069\u3046\u5de5\u592b\u3059\u308c\u3070\u3088\u3044\u306e\u304b\u304a\u5b50\u3055\u3093\u3068\u4e00\u7dd2\u306b\u8003\u3048\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" style=\"margin-left: 0;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/1722c37039e5c50950c01354c644ff01-150x150.jpg\" alt=\"\" width=\"80\" height=\"80\">\u3000<b>\u5b9f\u9a13\u3092\u767a\u5c55\u3055\u305b\u308b\u305f\u3081\u306e\u30d2\u30f3\u30c8<\/b><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u4e2d\u6027\u6d17\u5264\u306e\u30e1\u30fc\u30ab\u30fc\u3092\u5909\u3048\u3066\u307f\u305f\u3089\u3001\u7d50\u679c\u3082\u5909\u308f\u308b\u3067\u3057\u3087\u3046\u304b\uff1f<\/li>\n\n\n\n<li>\u5869\u306e\u91cf\u3092\u5909\u66f4\u3057\u305f\u3089\u3069\u3046\u306a\u308b\u3067\u3057\u3087\u3046\u3002<\/li>\n\n\n\n<li>\u62bd\u51fa\u6db2\u3092\u5165\u308c\u305f\u5f8c\u3084\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u5165\u308c\u305f\u5f8c\u3001\u6fc0\u3057\u304f\u304b\u304d\u6df7\u305c\u3066\u3082DNA\u306f\u62bd\u51fa\u3055\u308c\u308b\u3067\u3057\u3087\u3046\u304b\uff1f<\/li>\n\n\n\n<li>\u3044\u308d\u3093\u306a\u30d5\u30eb\u30fc\u30c4\u3084\u91ce\u83dc\u3067\u8a66\u3057\u3066\u307f\u3066\u3001\u306a\u305c\u305d\u306e\u7d50\u679c\u306b\u306a\u3063\u305f\u306e\u304b\u3001\u8003\u5bdf\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/li>\n<\/ul>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/about-us\/csr\/stay-home-stem.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_1_bid_ts_mbr_24072_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3053\u3061\u3089<\/a>\u304b\u3089\u3001DNA\u62bd\u51fa\u5b9f\u9a13\u306e\u52d5\u753b\u3082\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059<sup>\u203b<\/sup>\u3002<br>\u203b\u52d5\u753b\u3067\u306f\u3001\u30d7\u30ed\u304c\u4f7f\u3046\u30d4\u30da\u30c3\u30c8\u3084\u30b8\u30e7\u30a6\u30b4\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p>DNA\u306f\u3046\u307e\u304f\u62bd\u51fa\u3067\u304d\u307e\u3057\u305f\u304b\uff1f<br>\u5b9a\u756a\u306e\u5b9f\u9a13\u3067\u3042\u3063\u3066\u3082\u306a\u304f\u3066\u3082\u3001\u3044\u308d\u3093\u306a\u5834\u9762\u3067\u300c\u306a\u305c\u3060\u308d\u3046\u300d\u300c\u3053\u308c\u306f\u4f55\u3060\u308d\u3046\u300d\u3068\u7591\u554f\u3092\u6301\u3061\u7d9a\u3051\u308b\u3053\u3068\u304c\u3001\u79d1\u5b66\u3078\u306e\u8208\u5473\u3092\u6e67\u304d\u305f\u305f\u305b\u307e\u3059\u3002\u81ea\u7531\u7814\u7a76\u306f\u3001\u304a\u5b50\u3055\u3093\u304c\u79d1\u5b66\u3078\u306e\u8208\u5473\u3092\u6301\u3064\u305f\u3081\u306e\u304d\u3063\u304b\u3051\u306e\u3072\u3068\u3064\u3067\u3059\u3002\u305d\u3057\u3066\u305d\u306e\u5c0f\u3055\u306a\u304d\u3063\u304b\u3051\u304c\u3001\u3044\u305a\u308c\u4e16\u754c\u306e\u79d1\u5b66\u306e\u9032\u6b69\u3078\u3068\u3064\u306a\u304c\u3063\u3066\u3044\u304f\u304b\u3082\u77e5\u308c\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<div style=\"padding: 10px;margin-bottom: 10px;border: 3px solid red;border-radius: 10px\"><b>\u5b9f\u9a13\u4e0a\u306e\u6ce8\u610f\uff08\u4fdd\u8b77\u8005\u306e\u65b9\u3078\uff09<\/b><br>\u30fb\u5bfe\u8c61\u5e74\u9f62\u306f5\u6b73\u4ee5\u4e0a\u3067\u3059\u3002\u5c0f\u5b66\u751f\u4ee5\u4e0b\u306e\u304a\u5b50\u3055\u3093\u304c\u5b9f\u9a13\u3092\u8a66\u3059\u5834\u5408\u306f\u3001\u5fc5\u305a\u3054\u4e00\u7dd2\u306b\u304a\u9858\u3044\u3057\u307e\u3059\u3002<br>\u30fb\u5b9f\u9a13\u3092\u884c\u3046\u969b\u306f\u3001\u5fc5\u305a\u624b\u9806\u3092\u78ba\u304b\u3081\u3066\u304b\u3089\u5b9f\u65bd\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br>\u30fb\u6750\u6599\uff08\u6eb6\u6db2\u3001\u306f\u3055\u307f\u3001\u5668\u5177\u306a\u3069\uff09\u306e\u53d6\u308a\u6271\u3044\u306b\u5341\u5206\u306b\u6ce8\u610f\u3057\u3001\u30b1\u30ac\u306e\u306a\u3044\u3088\u3046\u306b\u3001\u500b\u4eba\u306e\u8cac\u4efb\u3067\u884c\u3063\u3066\u304f\u3060\u3055\u3044\u3002<br>\u30fb\u5b9f\u9a13\u3067\u4f5c\u3063\u305f\u3082\u306e\u3084\u4f7f\u3063\u305f\u3082\u306e\u306f\u98f2\u3093\u3060\u308a\u98df\u3079\u305f\u308a\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002<br>\u30fb\u30a8\u30bf\u30ce\u30fc\u30eb\u306f\u706b\u6c17\u53b3\u7981\u3067\u3059\u3002\u706b\u306e\u8fd1\u304f\u3067\u5b9f\u9a13\u3092\u3057\u306a\u3044\u3088\u3046\u306b\u3057\u307e\u3057\u3087\u3046\u3002<br>\u30fb\u6750\u6599\u3084\u74b0\u5883\u306b\u3088\u3063\u3066\u306f\u8a18\u4e8b\u901a\u308a\u306e\u7d50\u679c\u306b\u306a\u3089\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u66f4\u65b0\u65e5 : \u203b\u81ea\u7531\u7814\u7a76\u30c6\u30fc\u30de\u3092\u63a2\u3057\u3066\u3044\u308b\u304a\u7236\u3055\u3093\u304a\u6bcd\u3055\u3093\u3078\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306f\u3001\u304a\u3046\u3061\u6642\u9593\u3067\u306e\u79d1\u5b66\u5b66\u7fd2\u3092\u5fdc\u63f4\u3057\u3066\u3044\u307e\u3059\uff01\u300cDNA\u62bd\u51fa\u300d\u306f\u3001\u81ea\u7531\u7814\u7a76\u306e\u5b9a\u756a\u5b9f\u9a13\u306e\u3072\u3068\u3064\u3067\u3059\u3002 \u3057\u304b\u3057\u3001\u5b9a\u756a\u3060\u3068\u8ab0\u304b\u3068\u88ab\u3063\u3066<\/p>\n","protected":false},"author":975,"featured_media":18439,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[77],"division":[],"class_list":{"0":"post-18351","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-nucleic-acid-purification","9":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"DNA\u62bd\u51fa\u306e\u81ea\u7531\u7814\u7a76\u3068\u3057\u3066\u30a4\u30c1\u30b4\u3092\u4f7f\u3063\u305f\u5b9f\u9a13\u624b\u9806\u3092\u7d39\u4ecb\u3057\u3001\u754c\u9762\u6d3b\u6027\u5264\u30fb\u98df\u5869\u30fb\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u62bd\u51fa\u306e\u4ed5\u7d44\u307f\u3084DNA\u304c\u6790\u51fa\u3059\u308b\u7406\u7531\u3001\u5b9f\u9a13\u6642\u306e\u6ce8\u610f\u70b9\u3084\u5931\u6557\u6642\u306e\u78ba\u8a8d\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d\" \/>\n<meta property=\"og:description\" content=\"DNA\u62bd\u51fa\u306e\u81ea\u7531\u7814\u7a76\u3068\u3057\u3066\u30a4\u30c1\u30b4\u3092\u4f7f\u3063\u305f\u5b9f\u9a13\u624b\u9806\u3092\u7d39\u4ecb\u3057\u3001\u754c\u9762\u6d3b\u6027\u5264\u30fb\u98df\u5869\u30fb\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u62bd\u51fa\u306e\u4ed5\u7d44\u307f\u3084DNA\u304c\u6790\u51fa\u3059\u308b\u7406\u7531\u3001\u5b9f\u9a13\u6642\u306e\u6ce8\u610f\u70b9\u3084\u5931\u6557\u6642\u306e\u78ba\u8a8d\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-10-31T06:57:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-29T08:25:01+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1643\" \/>\n\t<meta property=\"og:image:height\" content=\"1619\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"17\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d\",\"datePublished\":\"2024-10-31T06:57:45+00:00\",\"dateModified\":\"2026-06-29T08:25:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/\"},\"wordCount\":87,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/10\\\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg\",\"keywords\":[\"\u6838\u9178\u7cbe\u88fd\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/\",\"name\":\"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/10\\\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg\",\"datePublished\":\"2024-10-31T06:57:45+00:00\",\"dateModified\":\"2026-06-29T08:25:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"description\":\"DNA\u62bd\u51fa\u306e\u81ea\u7531\u7814\u7a76\u3068\u3057\u3066\u30a4\u30c1\u30b4\u3092\u4f7f\u3063\u305f\u5b9f\u9a13\u624b\u9806\u3092\u7d39\u4ecb\u3057\u3001\u754c\u9762\u6d3b\u6027\u5264\u30fb\u98df\u5869\u30fb\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u62bd\u51fa\u306e\u4ed5\u7d44\u307f\u3084DNA\u304c\u6790\u51fa\u3059\u308b\u7406\u7531\u3001\u5b9f\u9a13\u6642\u306e\u6ce8\u610f\u70b9\u3084\u5931\u6557\u6642\u306e\u78ba\u8a8d\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/10\\\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/10\\\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg\",\"width\":1643,\"height\":1619},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-1-bid-ts-mbr-24072\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d - Learning at the Bench","description":"DNA\u62bd\u51fa\u306e\u81ea\u7531\u7814\u7a76\u3068\u3057\u3066\u30a4\u30c1\u30b4\u3092\u4f7f\u3063\u305f\u5b9f\u9a13\u624b\u9806\u3092\u7d39\u4ecb\u3057\u3001\u754c\u9762\u6d3b\u6027\u5264\u30fb\u98df\u5869\u30fb\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u62bd\u51fa\u306e\u4ed5\u7d44\u307f\u3084DNA\u304c\u6790\u51fa\u3059\u308b\u7406\u7531\u3001\u5b9f\u9a13\u6642\u306e\u6ce8\u610f\u70b9\u3084\u5931\u6557\u6642\u306e\u78ba\u8a8d\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/","og_locale":"ja_JP","og_type":"article","og_title":"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d","og_description":"DNA\u62bd\u51fa\u306e\u81ea\u7531\u7814\u7a76\u3068\u3057\u3066\u30a4\u30c1\u30b4\u3092\u4f7f\u3063\u305f\u5b9f\u9a13\u624b\u9806\u3092\u7d39\u4ecb\u3057\u3001\u754c\u9762\u6d3b\u6027\u5264\u30fb\u98df\u5869\u30fb\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u62bd\u51fa\u306e\u4ed5\u7d44\u307f\u3084DNA\u304c\u6790\u51fa\u3059\u308b\u7406\u7531\u3001\u5b9f\u9a13\u6642\u306e\u6ce8\u610f\u70b9\u3084\u5931\u6557\u6642\u306e\u78ba\u8a8d\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-10-31T06:57:45+00:00","article_modified_time":"2026-06-29T08:25:01+00:00","og_image":[{"width":1643,"height":1619,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"17\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d","datePublished":"2024-10-31T06:57:45+00:00","dateModified":"2026-06-29T08:25:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/"},"wordCount":87,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg","keywords":["\u6838\u9178\u7cbe\u88fd"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/","name":"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg","datePublished":"2024-10-31T06:57:45+00:00","dateModified":"2026-06-29T08:25:01+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"description":"DNA\u62bd\u51fa\u306e\u81ea\u7531\u7814\u7a76\u3068\u3057\u3066\u30a4\u30c1\u30b4\u3092\u4f7f\u3063\u305f\u5b9f\u9a13\u624b\u9806\u3092\u7d39\u4ecb\u3057\u3001\u754c\u9762\u6d3b\u6027\u5264\u30fb\u98df\u5869\u30fb\u51b7\u3084\u3057\u305f\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b\u62bd\u51fa\u306e\u4ed5\u7d44\u307f\u3084DNA\u304c\u6790\u51fa\u3059\u308b\u7406\u7531\u3001\u5b9f\u9a13\u6642\u306e\u6ce8\u610f\u70b9\u3084\u5931\u6557\u6642\u306e\u78ba\u8a8d\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg","width":1643,"height":1619},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-1-bid-ts-mbr-24072\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u81ea\u7531\u7814\u7a76\u300cDNA\u306e\u62bd\u51fa\u300d\uff5e\u30d7\u30ed\u304c\u6559\u3048\u308b\u300c\u306a\u305c\u300d\u3068\u300c\u306a\u306b\u300d"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":77,"label":"\u6838\u9178\u7cbe\u88fd"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1-1024x1009.jpg",760,749,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":77,"name":"\u6838\u9178\u7cbe\u88fd","slug":"nucleic-acid-purification","term_group":0,"term_taxonomy_id":77,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/10\/55d61328aa1dbf8f77abfd6ebb757486-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18351","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=18351"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18351\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/18439"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=18351"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=18351"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=18351"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=18351"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}