{"id":18441,"date":"2024-11-15T15:28:20","date_gmt":"2024-11-15T06:28:20","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=18441"},"modified":"2024-11-15T15:28:20","modified_gmt":"2024-11-15T06:28:20","slug":"mycoplasma-qpcr-3-bpg-24074","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/","title":{"rendered":"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9"},"content":{"rendered":"<p>\u54c1\u8cea\u8a66\u9a13\u306b\u95a2\u3059\u308b\u5c02\u9580\u7528\u8a9e\u306f\u96e3\u3057\u304f\u3066\u3001\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3068\u56f0\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u57fa\u790e\u7528\u8a9e\u3092\u5b66\u3076\u3068\u3068\u3082\u306b\u3001\u77e5\u3063\u3066\u304a\u304f\u3068\u4fbf\u5229\u306a\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u3055\u3066\u3001\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u306e\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u306f\u3001\u7279\u7570\u6027\u3001\u691c\u51fa\u611f\u5ea6\u3001\u9811\u5065\u6027\u304c\u975e\u5e38\u306b\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u306f\u3058\u3081\u3066\u306e\u5834\u5408\u3001\u3069\u306e\u3088\u3046\u306a\u6d41\u308c\u3067\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3057\u3066\u3044\u3051\u3070\u826f\u3044\u306e\u304b\u3001\u30a4\u30e1\u30fc\u30b8\u304c\u308f\u304b\u306a\u3044\u65b9\u3082\u591a\u3044\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u7121\u4e8b\u306b\u898f\u5236\u5f53\u5c40\u306b\u627f\u8a8d\u3055\u308c\u308b\u307e\u3067\u3001\u3069\u306e\u3088\u3046\u306b\u9032\u3081\u3066\u3044\u304f\u65b9\u6cd5\u304c\u3042\u308b\u306e\u304b\u7d39\u4ecb\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<br \/>\n\u627f\u8a8d\u307e\u3067\u306e\u6d41\u308c\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001\u5f53\u793e\u306e\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u6e08\u307f\u306e\u30ad\u30c3\u30c8\u304c\u3001\u3044\u304b\u306b\u52b9\u7387\u7684\u306a\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306b\u5f79\u7acb\u3064\u304b\u3092\u77e5\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br \/>\n\u30fb\u533b\u85ac\u54c1\u306e\u54c1\u8cea\u8a66\u9a13\u3067\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u3092\u5b9f\u65bd\u3059\u308b\u4e88\u5b9a\u306e\u65b9<br \/>\n\u30fb\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u306e\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306b\u8208\u5473\u306e\u3042\u308b\u65b9<\/p>\n<h2>\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u304c\u5fc5\u8981\u306a\u7406\u7531<\/h2>\n<p>\u533b\u85ac\u54c1\u306e\u81e8\u5e8a\u8a66\u9a13\u304a\u3088\u3073\u88fd\u9020\u8ca9\u58f2\u627f\u8a8d\u7533\u8acb\u306e\u305f\u3081\u306e\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u306e\u5834\u5408\u3001\u65e5\u672c\u85ac\u5c40\u65b9\u3067\u306f\u5f93\u6765\u6cd5\uff08A\u6cd5:\u57f9\u990a\u6cd5\u3001B\u6cd5:\u6307\u6a19\u7d30\u80de\u3092\u7528\u3044\u305fDNA\u67d3\u8272\u6cd5\uff09\u3068\u3001\u65b0\u305f\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3068\u3057\u3066\u52a0\u308f\u3063\u305fC\u6cd5:\u6838\u9178\u5897\u5e45\u6cd5\u306e3\u3064\u306e\u624b\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u7528\u3044\u305f\u624b\u6cd5\u306fC\u6cd5:\u6838\u9178\u5897\u5e45\u6cd5\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u5f93\u6765\u6cd5\u3068\u540c\u7b49\u306e\u7cbe\u5ea6\u3092\u793a\u3059\u305f\u3081\u306b\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3059\u308b\u3053\u3068\u304c\u8981\u6c42\u3055\u308c\u307e\u3059\u3002<\/p>\n<table>\n<caption><b>\u88681. \u65e5\u672c\u85ac\u5c40\u65b9\u306b\u304a\u3051\u308bC\u6cd5\u306e\u4f4d\u7f6e\u3065\u3051<\/b><\/caption>\n<tbody>\n<tr bgcolor=\"#666666\">\n<td style=\"text-align: center\" width=\"500\" colspan=\"2\"><font color=\"white\"><b>\u7b2c18\u6539\u6b63\u65e5\u672c\u85ac\u5c40\u65b9<\/b><\/font><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"200\"><b>\u8a66\u9a13\u6cd5<\/b><\/td>\n<td style=\"text-align: left\" width=\"500\">\u30fb\u57f9\u990a\u6cd5\uff08A\u6cd5\uff09<br \/>\u30fb\u6307\u6a19\u7d30\u80de\u3092\u7528\u3044\u305fDNA\u67d3\u8272\u6cd5\uff08B\u6cd5\uff09<br \/>\u30fb\u6838\u9178\u5897\u5e45\u6cd5\uff08C\u6cd5\uff09<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"200\"><b>\u8a66\u9a13\u6cd5\u306e\u9078\u629e<\/b><\/td>\n<td style=\"text-align: left\" width=\"500\">\u30fbA\u6cd5\u3001B\u6cd5\u3092\u5b9f\u65bd\u3059\u308b\u3002<br \/><font color=\"red\"><b>\u30fb\u9069\u5207\u306a\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3067\u3001<br \/>\u3000C\u6cd5\u3092A\u6cd5\u3001B\u6cd5\u306e\u4ee3\u66ff\u6cd5\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u3002<\/b><\/font><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"200\"><b>\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e<br \/>\u8a55\u4fa1\u9805\u76ee<\/b><\/td>\n<td style=\"text-align: left\" width=\"500\">\u30fb\u7279\u7570\u6027<br \/>\u30fb\u691c\u51fa\u9650\u754c<br \/>&emsp;&emsp;\u30fbA\u6cd5\u306e\u4ee3\u66ff\u6761\u4ef6\uff1a\u611f\u5ea610CFU\/mL<br \/>&emsp;&emsp;\u30fbB\u6cd5\u306e\u4ee3\u66ff\u6761\u4ef6\uff1a\u611f\u5ea6100CFU\/mL<br \/>\u30fb\u9811\u5065\u6027<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: center\" width=\"200\"><b>\u691c\u51fa\u5bfe\u8c61<\/b><\/td>\n<td style=\"text-align: left\" width=\"500\">7\u83cc\u7a2e<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u8a66\u9a13\u65b9\u6cd5\u306e\u6700\u9069\u5316\u3068\u30d7\u30ec\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3<\/h2>\n<p>\u307e\u305a\u3001\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u524d\u6bb5\u968e\u3068\u3057\u3066\u3001\u8a66\u9a13\u65b9\u6cd5\u306e\u6700\u9069\u5316\u3068\u30d7\u30ec\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u30fb\u9069\u683c\u6027\u8a55\u4fa1\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002<\/p>\n<p>\u3010\u8a66\u9a13\u65b9\u6cd5\u306e\u6700\u9069\u5316\u3011<br \/>\nStep 1<br \/>\n\u304a\u5ba2\u3055\u307e\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u4f7f\u3063\u3066\u3001\u63a8\u5968\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u3067\u554f\u984c\u306a\u304f\u8a66\u9a13\u304c\u3067\u304d\u308b\u304b\u78ba\u8a8d\u3057\u307e\u3059\u3002\u3053\u306e\u6642\u3001\u65e5\u672c\u85ac\u5c40\u65b9\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u611f\u5ea6\u3092\u6e80\u305f\u305b\u308b\u304b\u3001\u30b5\u30f3\u30d7\u30eb\uff0bDPC\uff08\u30ad\u30c3\u30c8\u306b\u4ed8\u5c5e\u306e\u30dd\u30b8\u30c6\u30a3\u30d6\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\uff09\u30b9\u30d1\u30a4\u30af\u8a66\u9a13\u3067\u300110 GC\/mL\u306e\u611f\u5ea6\u3092\u9054\u6210\u3067\u304d\u308b\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/p>\n<p>Step 2<br \/>\n\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u30dd\u30a4\u30f3\u30c8\u3092\u6c7a\u5b9a\u3057\u307e\u3059\u3002\u7d30\u80de\u306e\u30cf\u30fc\u30d9\u30b9\u30c8\u6bb5\u968e\u3060\u3051\u3067\u8a66\u9a13\u3059\u308b\u306e\u3067\u306f\u306a\u304f\u3001\u57f9\u990a\u9014\u4e2d\u306e\u4e0a\u6e05\u306a\u3069\u3092\u4f7f\u3063\u3066\u5de5\u7a0b\u5185\u8a66\u9a13\u3092\u884c\u3046\u3068\u3001\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u6c5a\u67d3\u306e\u30ea\u30b9\u30af\u3092\u3088\u308a\u8efd\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u3010\u30d7\u30ec\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3011<br \/>\n\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u30b2\u30ce\u30e0DNA\u3092\u7528\u3044\u3066\u4e88\u5099\u5b9f\u9a13\u3092\u884c\u3044\u307e\u3059\u3002<br \/>\nStep 1\u3068\u540c\u69d8\u306b\u3001\u65e5\u672c\u85ac\u5c40\u6cd5\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u611f\u5ea6\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u3067\u304d\u308b\u304b\u3001\u30b5\u30f3\u30d7\u30eb\uff0b\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u30b2\u30ce\u30e0DNA\u30b9\u30d1\u30a4\u30af\u8a66\u9a13\u3067\u300110 GC\/mL\u306e\u611f\u5ea6\u3092\u9054\u6210\u3067\u304d\u308b\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<br \/>\n<div id=\"attachment_18453\" style=\"width: 1070px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18453\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/7c4a435789f5e925d4b80362c0af4829.png\" alt=\"\u56f31. \u4e00\u822c\u7684\u306a\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u30d5\u30ed\u30fc\" width=\"1060\" height=\"239\" class=\"size-full wp-image-18453\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/7c4a435789f5e925d4b80362c0af4829.png 1060w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/7c4a435789f5e925d4b80362c0af4829-300x68.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/7c4a435789f5e925d4b80362c0af4829-1024x231.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/7c4a435789f5e925d4b80362c0af4829-768x173.png 768w\" sizes=\"auto, (max-width: 1060px) 100vw, 1060px\" \/><p id=\"caption-attachment-18453\" class=\"wp-caption-text\">\u56f31. \u4e00\u822c\u7684\u306a\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u30d5\u30ed\u30fc<\/p><\/div><\/p>\n<h2>\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u5b9f\u65bd\u3068\u627f\u8a8d\u7533\u8acb<\/h2>\n<p>\u3010\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u5b9f\u65bd\u3011<br \/>\nStep 1<br \/>\n\u30d7\u30ec\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u7d50\u679c\u3092\u3082\u3068\u306b\u3001\u898f\u5236\u5f53\u5c40\u3068\u4e8b\u524d\u9762\u8ac7\u3057\u3001\u5b9f\u969b\u306e\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u5185\u5bb9\u3092\u76f8\u8ac7\u3057\u307e\u3059\u3002\u304a\u5ba2\u3055\u307e\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u7528\u3044\u3066\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u3059\u304c\u3001\u5f53\u793e\u306e\u30ad\u30c3\u30c8\u3092\u3054\u4f7f\u7528\u306e\u5834\u5408\u3001\u53c2\u8003\u8cc7\u6599\u3068\u3057\u3066\u5f53\u793e\u304c\u53d6\u5f97\u3057\u305f\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u30ec\u30dd\u30fc\u30c8\u3092\u63d0\u4f9b\u3067\u304d\u307e\u3059\u306e\u3067\u3001\u304a\u5ba2\u3055\u307e\u81ea\u8eab\u304c1\u304b\u3089\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<p>Step.2<br \/>\n\u898f\u5236\u5f53\u5c40\u3068\u306e\u9762\u8ac7\u7d50\u679c\u3092\u8e0f\u307e\u3048\u305f\u30d7\u30e9\u30f3\u306b\u5f93\u3044\u3001\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3057\u307e\u3059\u3002<\/p>\n<p>\u3010\u898f\u5236\u5f53\u5c40\u3078\u306e\u627f\u8a8d\u7533\u8acb\u3011<br \/>\nStep.1<br \/>\n\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u7d50\u679c\u3092\u3082\u3068\u306b\u898f\u5236\u5f53\u5c40\u306b\u533b\u85ac\u54c1\u306e\u627f\u8a8d\u7533\u8acb\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n<p>Step.2<br \/>\n\u627f\u8a8d\u5f8c\u3001\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3092\u3068\u3063\u305f\u30d7\u30ed\u30c8\u30b3\u30fc\u30eb\uff08SOP\uff09\u306b\u5f93\u3063\u3066\u3001\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u3092\u5b9f\u65bd\u3057\u3066\u3044\u304d\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e8378b63c768e480fd9d4cebf2f1eb96-300x232.jpg\" alt=\"\" width=\"300\" height=\"232\" class=\"aligncenter size-medium wp-image-18454\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e8378b63c768e480fd9d4cebf2f1eb96-300x232.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e8378b63c768e480fd9d4cebf2f1eb96-768x594.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e8378b63c768e480fd9d4cebf2f1eb96.jpg 1008w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u304b\uff1f<br \/>\n\u5b89\u5168\u306a\u533b\u85ac\u54c1\u3092\u63d0\u4f9b\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u304d\u3061\u3093\u3068\u30d0\u30ea\u30c7\u30fc\u30c8\u3055\u308c\u305f\u65b9\u6cd5\u3067\u8a66\u9a13\u3092\u5b9f\u65bd\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306f\u624b\u9593\u3068\u6642\u9593\u306e\u304b\u304b\u308b\u5927\u5909\u306a\u4f5c\u696d\u3067\u3059\u3002\u305d\u3053\u3067\u3001\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u6e08\u307f\u306e\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u898f\u5236\u5f53\u5c40\u3068\u306e\u9762\u8ac7\u6642\u306b\u53c2\u8003\u8cc7\u6599\u3068\u3057\u3066\u3001\u5f53\u793e\u304c\u53d6\u5f97\u3057\u305f\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u30ec\u30dd\u30fc\u30c8\u3092\u63d0\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u304a\u5ba2\u3055\u307e\u81ea\u8eab\u30671\u304b\u3089\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u8a66\u9a13\u3092\u3059\u308b\u5fc5\u8981\u304c\u306a\u3044\u305f\u3081\u4f5c\u696d\u306b\u304b\u304b\u308b\u8ca0\u62c5\u304c\u8efd\u6e1b\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>Applied Biosystems\u2122 MycoSEQ\u2122 Plus Mycoplasma Detection Kit\u306f\u3001\u7d30\u80de\u6cbb\u7642\u3084\u8907\u96d1\u306a\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30b5\u30f3\u30d7\u30eb\u306b\u304a\u3051\u308b\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u306e\u691c\u51fa\u306b\u7279\u5316\u3057\u3066\u958b\u767a\u3055\u308c\u305fTaqMan\u2122\u30d9\u30fc\u30b9\u306e\u30ad\u30c3\u30c8\u3067\u3001\u898f\u5236\u3067\u8981\u6c42\u3055\u308c\u308b10 CFU\/mL\u304b\u305d\u308c\u4ee5\u4e0a\u306e\u9ad8\u3044\u611f\u5ea6\u3068\u7279\u7570\u6027\u3092\u6301\u3061\u3001\u88fd\u54c1\u306e\u30ed\u30c3\u30c8\u30ea\u30ea\u30fc\u30b9\u8a66\u9a13\u306b\u5bfe\u5fdc\u3059\u308b\u306e\u306b\u5fc5\u8981\u306a\u6027\u80fd\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u305c\u3072\u3001\u30dd\u30b9\u30bf\u30fc\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3066\u3001\u3053\u306e\u88fd\u54c1\u306e\u8a73\u3057\u3044\u6027\u80fd\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/mycoseq-plus-poster.html?CID=bpg_bpg_r04_jp_cp0000_pjt0000_bpg00000_0so_blg_mycoplasma_qpcr_3_bpg_24074_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<p>TaqMan is a trademark of Roche Molecular Systems, Inc., used under permission and license.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u54c1\u8cea\u8a66\u9a13\u306b\u95a2\u3059\u308b\u5c02\u9580\u7528\u8a9e\u306f\u96e3\u3057\u304f\u3066\u3001\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3068\u56f0\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u57fa\u790e\u7528\u8a9e\u3092\u5b66\u3076\u3068\u3068\u3082\u306b\u3001\u77e5\u3063\u3066\u304a\u304f\u3068\u4fbf\u5229\u306a\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u3066\u3044\u307e\u3059\u3002 \u3055\u3066\u3001\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u306e\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u306f\u3001<\/p>\n","protected":false},"author":975,"featured_media":18455,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[230,7],"division":[],"class_list":{"0":"post-18441","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-mycoplasma","9":"tag-qpcr","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9\" \/>\n<meta property=\"og:description\" content=\"\u54c1\u8cea\u8a66\u9a13\u306b\u95a2\u3059\u308b\u5c02\u9580\u7528\u8a9e\u306f\u96e3\u3057\u304f\u3066\u3001\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3068\u56f0\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u57fa\u790e\u7528\u8a9e\u3092\u5b66\u3076\u3068\u3068\u3082\u306b\u3001\u77e5\u3063\u3066\u304a\u304f\u3068\u4fbf\u5229\u306a\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u3066\u3044\u307e\u3059\u3002 \u3055\u3066\u3001\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u306e\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u306f\u3001\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-15T06:28:20+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9\",\"datePublished\":\"2024-11-15T06:28:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/\"},\"wordCount\":73,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/f8000798beb94cb95cbdfe439765205d.jpg\",\"keywords\":[\"\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\",\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/\",\"name\":\"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/f8000798beb94cb95cbdfe439765205d.jpg\",\"datePublished\":\"2024-11-15T06:28:20+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/f8000798beb94cb95cbdfe439765205d.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/f8000798beb94cb95cbdfe439765205d.jpg\",\"width\":1000,\"height\":667},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/mycoplasma-qpcr-3-bpg-24074\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9","og_description":"\u54c1\u8cea\u8a66\u9a13\u306b\u95a2\u3059\u308b\u5c02\u9580\u7528\u8a9e\u306f\u96e3\u3057\u304f\u3066\u3001\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\u3068\u56f0\u3063\u305f\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u57fa\u790e\u7528\u8a9e\u3092\u5b66\u3076\u3068\u3068\u3082\u306b\u3001\u77e5\u3063\u3066\u304a\u304f\u3068\u4fbf\u5229\u306a\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u3066\u3044\u307e\u3059\u3002 \u3055\u3066\u3001\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u306e\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306b\u304a\u3044\u3066\u306f\u3001","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-11-15T06:28:20+00:00","og_image":[{"width":1000,"height":667,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9","datePublished":"2024-11-15T06:28:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/"},"wordCount":73,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg","keywords":["\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de","\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/","name":"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg","datePublished":"2024-11-15T06:28:20+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg","width":1000,"height":667},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/mycoplasma-qpcr-3-bpg-24074\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308b\uff01\u3011\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de\u5426\u5b9a\u8a66\u9a13\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u9032\u3081\u65b9"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":230,"label":"\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de"},{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg",760,507,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":230,"name":"\u30de\u30a4\u30b3\u30d7\u30e9\u30ba\u30de","slug":"mycoplasma","term_group":0,"term_taxonomy_id":230,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]},{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/f8000798beb94cb95cbdfe439765205d.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18441","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=18441"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18441\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/18455"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=18441"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=18441"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=18441"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=18441"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}