{"id":18561,"date":"2024-11-20T17:17:17","date_gmt":"2024-11-20T08:17:17","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=18561"},"modified":"2024-12-25T15:53:22","modified_gmt":"2024-12-25T06:53:22","slug":"cell-culture-cell-count-workshop-bid-ts-mbr-24080","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f"},"content":{"rendered":"<p>Trypsin\u306f\u63a5\u7740\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u3067\u3059\u3002\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306e\u6d88\u5316\u4f5c\u7528\u306b\u3088\u3063\u3066\u7d30\u80de\u540c\u58eb\u306e\u63a5\u7740\u3068\u7d30\u80de\u3068\u30c7\u30a3\u30c3\u30b7\u30e5\u3068\u306e\u63a5\u7740\u306e\u89e3\u96e2\u3092\u4fc3\u3057\u307e\u3059\uff08<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell_culture_history_1_bid_ts_1\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u95a2\u9023\u8a18\u4e8b<\/a>\uff09\u3002Trypsin\u306f\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306b\u9650\u3089\u305a\u7d30\u80de\u8868\u9762\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6d88\u5316\u3059\u308b\u306e\u3067\u3001\u904e\u5270\u306a\u51e6\u7406\u306f\u7d30\u80de\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7d30\u80de\u89e3\u96e2\u306b\u304a\u3044\u3066\u306f\u5fc5\u8981\u6700\u5c0f\u9650\u306eTrypsin\u51e6\u7406\u3068\u3059\u308b\u306e\u304c\u5b9a\u77f3\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3067\u306f\u3001\u7d30\u80de\u304cTrypsin\u306b\u66dd\u3055\u308c\u7d9a\u3051\u308b\u3068\u4f55\u304c\u8d77\u3053\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u4eca\u56de\u306f\u3001\u30c7\u30a3\u30c3\u30b7\u30e5\u304b\u3089\u5265\u304c\u3057\u305fHeLa\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u7d9a\u3051\u306a\u304c\u3089\u3001\u751f\u5b58\u7387\u3001\u7d30\u80de\u306e\u6fc3\u5ea6\u306a\u3069\u3092\u8ffd\u8de1\u3057\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n<h2>\u5b9f\u9a13\u65b9\u6cd5<\/h2>\n<p><b>\u30fb\u7d30\u80de\uff1a<\/b><br \/>\n&emsp;\u30b5\u30d6\u30b3\u30f3\u30d5\u30eb\u30a8\u30f3\u30c8\u306eHeLa\u7d30\u80de<\/p>\n<p><b>\u30fb\u624b\u9806<\/b><\/p>\n<ol>\n<li>\u57f9\u5730\u3092\u30a2\u30b9\u30d4\u30ec\u30fc\u30c8\u3057\u3066Gibco\u2122 DPBS\uff08\u88fd\u54c1\u756a\u53f7<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/14190144?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">14190144<\/a>\uff09\u3067\u30ea\u30f3\u30b9<\/li>\n<li>Gibco\u2122 Trypsin\uff080.25%\uff09Phenol Red\u542b\u6709\uff08\u88fd\u54c1\u756a\u53f7<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/15050065?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">15050065<\/a>\u3001\u56f31\uff09\u3092\u6dfb\u52a0<\/li>\n<li>CO<sub>2<\/sub>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u3067\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3<\/li>\n<li>\u8efd\u304f\u30c7\u30a3\u30c3\u30b7\u30e5\u3092\u53e9\u3044\u3066\u307b\u3068\u3093\u3069\u306e\u7d30\u80de\u304c\u5265\u304c\u308c\u305f\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304b\u3089\u3001\u30a6\u30b7\u80ce\u4ed4\u8840\u6e05\u5165\u308a\u306eDMEM\uff08\u5b8c\u5168\u57f9\u5730\uff09\u3092\u52a0\u3048\u3066Trypsin\u51e6\u7406\u3092\u505c\u6b62<\/li>\n<li>\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u30c1\u30e5\u30fc\u30d6\u306b\u56de\u53ce\u3057\u3066\u9060\u5fc3\u5206\u96e2<\/li>\n<li>\u4e0a\u6f84\u307f\u3092\u30a2\u30b9\u30d4\u30ec\u30fc\u30c8\u3057\u3066\u65b0\u9bae\u306a\u5b8c\u5168\u57f9\u5730\u3067\u518d\u61f8\u6fc1<\/li>\n<li>Gibco\u2122 Trypan Blue 0.4%\u6eb6\u6db2\uff08\u88fd\u54c1\u756a\u53f7<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/15250061?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">15250061<\/a>\uff09\u3068\u7d30\u80de\u61f8\u6fc1\u6db2\u30921:1\u3067\u6df7\u5408\u3057\u3066Invitrogen\u2122 Countess\u2122 Chamber Slide\uff08\u88fd\u54c1\u756a\u53f7<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10283?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">C10283<\/a>\uff09\u306b\u6ce8\u5165<\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/cell-analysis\/cell-analysis-instruments\/automated-cell-counters\/models\/countess-3-fl.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">Invitrogen\u2122 Countess\u2122 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc<\/a>\u306e\u660e\u8996\u91ce\u30e2\u30fc\u30c9\uff08\u30c7\u30d5\u30a9\u30eb\u30c8\u8a2d\u5b9a\uff09\u3067\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8<\/li>\n<li>\u3053\u306e\u6642\u306e\u751f\u5b58\u7387\u306f\u5e73\u574796.5%\u3001\u7d30\u80de\u6fc3\u5ea6\u306f2.1 x 10<sup>6<\/sup> cells\/mL\u3002\u3053\u306e\u6642\u70b9\u3092\u51e6\u7406\u6642\u95930\u5206\u3068\u8a2d\u5b9a<\/li>\n<li>\u51e6\u7406\u6642\u95930\u5206\u306e\u6e2c\u5b9a\u5f8c\u3001\u9060\u5fc3\u5206\u96e2\u3057\u3066\u4e0a\u6f84\u307f\u3092\u30a2\u30b9\u30d4\u30ec\u30fc\u30c8\u3057\u3001DPBS\u3067\u7d30\u80de\u3092\u6d17\u6d44<\/li>\n<li>\u518d\u5ea6\u9060\u5fc3\u5206\u96e2\u3057\u30660.25% Trypsin\u306b\u518d\u61f8\u6fc1<\/li>\n<li>37\u2103\u306e\u6e29\u6d74\u3067\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30c8\u3092\u518d\u958b<\/li>\n<li>10\u300120\u300130\u300140\u300160\u5206\u5f8c\u306b\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3057\u3066Countess 3 FL\u3067\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8<\/li>\n<\/ol>\n<div id=\"attachment_18565\" style=\"width: 302px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18565\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/da681d26e40027f42d01d85d788a8335.png\" alt=\"\u56f31. Trypsin (0.25%), phenol red\" width=\"292\" height=\"494\" class=\"size-full wp-image-18565\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/da681d26e40027f42d01d85d788a8335.png 521w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/da681d26e40027f42d01d85d788a8335-177x300.png 177w\" sizes=\"auto, (max-width: 292px) 100vw, 292px\" \/><p id=\"caption-attachment-18565\" class=\"wp-caption-text\">\u56f31. Trypsin (0.25%), phenol red<\/p><\/div>\n<h2>\u904e\u5270\u306aTrypsin\u51e6\u7406\u304c\u751f\u5b58\u7387\u3068\u7d30\u80de\u6fc3\u5ea6\u306e\u6e2c\u5b9a\u306b\u53ca\u307c\u3059\u5f71\u97ff<\/h2>\n<p>\u305d\u308c\u3067\u306f\u6e2c\u5b9a\u7d50\u679c\u3092\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002Trypsin\u51e6\u7406\u306b\u3088\u308b\u751f\u5b58\u7387\u3068\u7d30\u80de\u6fc3\u5ea6\u306e\u5909\u5316\u3092\u30b0\u30e9\u30d5\u5316\u3057\u307e\u3057\u305f\uff08\u56f32\u3001\u56f33\uff09\u3002<br \/>\n<div id=\"attachment_18566\" style=\"width: 769px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18566\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/88329f8e6e0bf0968fab1d5ea7bfdafb.jpg\" alt=\"\u56f32. \u904e\u5270\u306aTrypsin\u51e6\u7406\u306b\u3088\u308b\u7d30\u80de\u306e\u751f\u5b58\u7387\u306e\u5909\u5316\" width=\"759\" height=\"447\" class=\"size-full wp-image-18566\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/88329f8e6e0bf0968fab1d5ea7bfdafb.jpg 2532w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/88329f8e6e0bf0968fab1d5ea7bfdafb-300x177.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/88329f8e6e0bf0968fab1d5ea7bfdafb-1024x603.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/88329f8e6e0bf0968fab1d5ea7bfdafb-768x452.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/88329f8e6e0bf0968fab1d5ea7bfdafb-1536x904.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/88329f8e6e0bf0968fab1d5ea7bfdafb-2048x1206.jpg 2048w\" sizes=\"auto, (max-width: 759px) 100vw, 759px\" \/><p id=\"caption-attachment-18566\" class=\"wp-caption-text\">\u56f32. \u904e\u5270\u306aTrypsin\u51e6\u7406\u306b\u3088\u308b\u7d30\u80de\u306e\u751f\u5b58\u7387\u306e\u5909\u5316<\/p><\/div><br \/>\n<div id=\"attachment_18567\" style=\"width: 2570px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18567\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/480253f6b81e522ede42bce9189d291c-scaled.jpg\" alt=\"\u56f33. \u904e\u5270\u306aTrypsin\u51e6\u7406\u306b\u3088\u308b\u7d30\u80de\u6fc3\u5ea6\u306e\u4f4e\u4e0b\" width=\"2560\" height=\"1479\" class=\"size-full wp-image-18567\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/480253f6b81e522ede42bce9189d291c-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/480253f6b81e522ede42bce9189d291c-300x173.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/480253f6b81e522ede42bce9189d291c-1024x591.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/480253f6b81e522ede42bce9189d291c-768x444.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/480253f6b81e522ede42bce9189d291c-1536x887.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/480253f6b81e522ede42bce9189d291c-2048x1183.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><p id=\"caption-attachment-18567\" class=\"wp-caption-text\">\u56f33. \u904e\u5270\u306aTrypsin\u51e6\u7406\u306b\u3088\u308b\u7d30\u80de\u6fc3\u5ea6\u306e\u4f4e\u4e0b<\/p><\/div><br \/>\n\u51e6\u7406\u6642\u959320\u5206\u307e\u3067\u306f95%\u7a0b\u5ea6\u306e\u751f\u5b58\u7387\u3092\u7dad\u6301\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001\u7d30\u80de\u306e\u6fc3\u5ea6\u306f2.1 x 10<sup>6<\/sup> cells\/mL\u304b\u30891.5 x 10<sup>6<\/sup> cell\/mL\u307e\u3067\u30013\u5272\u307b\u3069\u4f4e\u4e0b\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306fTrypsin\u306b\u3088\u3063\u3066\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u305f\u7d30\u80de\u304c\u58ca\u308c\u308b\u306a\u3069\u3057\u3066Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306b\u3088\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u5bfe\u8c61\u5916\u306b\u306a\u3063\u305f\u305f\u3081\u3060\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u305d\u3057\u3066\u51e6\u7406\u6642\u959330\u5206\u3067\u751f\u5b58\u7387\u304c59%\u3078\u5927\u304d\u304f\u4f4e\u4e0b\u3057\u307e\u3057\u305f\u3002\u51e6\u74060\u5206\u306830\u5206\u306e\u7d30\u80de\u306e\u69d8\u5b50\u3068\u751f\u6b7b\u5224\u5b9a\u7d50\u679c\u3092\u56f34\u306b\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u51e6\u740660\u5206\u3067\u306f\u300130\u5206\u308440\u5206\u3088\u308a\u3082\u751f\u5b58\u7387\u304c\u9ad8\u3044\u3068\u3044\u3046\u7d50\u679c\u304c\u51fa\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u904e\u5270\u306aTrypsin\u51e6\u7406\u306b\u3088\u3063\u3066\u767a\u751f\u3057\u305f\u591a\u6570\u306e\u7d30\u80de\u306e\u7834\u7247\u304c\u751f\u7d30\u80de\u3068\u5224\u5b9a\u3055\u308c\u305f\u305f\u3081\u3060\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3053\u3061\u3089\u306b\u3064\u3044\u3066\u306f\u89e3\u6c7a\u65b9\u6cd5\u3092\u542b\u3081\u3066\u8ffd\u3063\u3066\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002<br \/>\n<div id=\"attachment_18568\" style=\"width: 666px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18568\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/d5ff6a58ec6ab54b1a61c2fef28a5388.png\" alt=\"\u56f34. \u51e6\u74060\u5206\u306830\u5206\u5f8c\u306e\u7d30\u80de\u306e\u72b6\u614b\u6bd4\u8f03\" width=\"656\" height=\"416\" class=\"size-full wp-image-18568\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/d5ff6a58ec6ab54b1a61c2fef28a5388.png 1489w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/d5ff6a58ec6ab54b1a61c2fef28a5388-300x190.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/d5ff6a58ec6ab54b1a61c2fef28a5388-1024x649.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/d5ff6a58ec6ab54b1a61c2fef28a5388-768x487.png 768w\" sizes=\"auto, (max-width: 656px) 100vw, 656px\" \/><p id=\"caption-attachment-18568\" class=\"wp-caption-text\">\u56f34. \u51e6\u74060\u5206\u306830\u5206\u5f8c\u306e\u7d30\u80de\u306e\u72b6\u614b\u6bd4\u8f03<\/p><\/div><br \/>\n\u4eca\u56de\u306f\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fcCountess 3 FL\u3067\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3057\u307e\u3057\u305f\u3002Countess 3 FL\u306f\u3001\u7d30\u80de\u306e\u5199\u771f\u3092\u64ae\u5f71\u3057\u3001\u72ec\u81ea\u306e\u753b\u50cf\u89e3\u6790\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u7d30\u80de\u3092\u7279\u5b9a\u3057\u3066\u751f\u6b7b\u5224\u5b9a\u30fb\u6fc3\u5ea6\u6e2c\u5b9a\u3092\u884c\u3044\u307e\u3059\u3002\u64ae\u5f71\u3057\u305f\u753b\u50cf\u3092\u78ba\u8a8d\u3057\u306a\u304c\u3089\u3001\u7d30\u80de\u306e\u5927\u304d\u3055\u3001\u660e\u308b\u3055\u3001\u771f\u5186\u5ea6\u306e3\u3064\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u95be\u5024\u3092\u8abf\u7bc0\u3057\u3066\u3001\u6e2c\u5b9a\u5bfe\u8c61\u306e\u7d30\u80de\u3092\u8a2d\u5b9a\u3067\u304d\u307e\u3059\u3002\u3067\u3059\u304c\u4eca\u56de\u306f\u3042\u3048\u3066\u30c7\u30d5\u30a9\u30eb\u30c8\u8a2d\u5b9a\u3067\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3092\u884c\u3063\u305f\u3068\u3053\u308d\u30012\u3064\u306e\u9762\u3067\u5224\u5b9a\u7d50\u679c\u306b\u7591\u554f\u304c\u751f\u3058\u307e\u3057\u305f\u3002<\/p>\n<p>\u56f34\u306b\u304a\u3044\u3066\u3001\u51e6\u74060\u5206\u306830\u5206\u306e\u3069\u3061\u3089\u306e\u5199\u771f\u306b\u3082\u3001\u5178\u578b\u7684\u306a\u5927\u304d\u3055\u306e\u7d30\u80de\u3088\u308a\u3082\u5c0f\u3055\u3044\u7c92\u5b50\uff08\u7d30\u80de\u306e\u7834\u7247\uff1f\u3001\u9ec4\u8272\u77e2\u5370\uff09\u304c\u3042\u308a\u3001\u751f\u7d30\u80de\u5224\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u7c92\u5b50\u306f\u7d30\u80de\u3067\u306f\u306a\u3044\u3068\u5224\u65ad\u3057\u3066\u30ab\u30a6\u30f3\u30c8\u304b\u3089\u9664\u5916\u3059\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u64ae\u5f71\u5f8c\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8abf\u6574\u306b\u304a\u3044\u3066\u3001Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306b\u6e2c\u5b9a\u5bfe\u8c61\u3068\u8a8d\u8b58\u3055\u305b\u308b\u7d30\u80de\u306e\u5927\u304d\u3055\u306e\u95be\u5024\u3092\u8abf\u7bc0\u3059\u308b\u3053\u3068\u3067\u5bfe\u5fdc\u3067\u304d\u307e\u3059\uff08\u56f35\uff09\u3002\u51e6\u74060\u5206\u3067\u306f\u5c0f\u3055\u3044\u7c92\u5b50\u306f\u308f\u305a\u304b\u306e\u305f\u3081\u6e2c\u5b9a\u7d50\u679c\u306b\u307b\u3068\u3093\u3069\u5f71\u97ff\u3057\u306a\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u51e6\u740630\u5206\u3067\u306f\u591a\u6570\u306e\u7c92\u5b50\u304c\u5b58\u5728\u3057\u3066\u3044\u305f\u305f\u3081\u3001\u3053\u308c\u3089\u3092\u9664\u5916\u3057\u3066\u8a08\u7b97\u3057\u76f4\u3059\u3068\u751f\u5b58\u7387\u304c\u5927\u304d\u304f\u4f4e\u4e0b\u3057\u305f\u306f\u305a\u3067\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u591a\u304f\u306e\u751f\u7d30\u80de\u3088\u308a\u3082\u660e\u308b\u3055\u304c\u6697\u3044\uff08\u30c8\u30ea\u30d1\u30f3\u30d6\u30eb\u30fc\u3067\u67d3\u307e\u3063\u3066\u3044\u308b\uff09\u306b\u3082\u304b\u304b\u308f\u3089\u305a\u751f\u7d30\u80de\u3068\u5224\u5b9a\u3055\u308c\u3066\u3044\u308b\u7d30\u80de\u304c\u3042\u308a\u307e\u3057\u305f\uff08\u7d2b\u8272\u77e2\u5370\uff09\u3002\u3088\u304f\u898b\u308b\u3068\u3001\u6b7b\u7d30\u80de\u3068\u5224\u5b9a\u3055\u308c\u305f\u7d30\u80de\u3088\u308a\u3082\u308f\u305a\u304b\u306b\u660e\u308b\u3044\u305f\u3081\u3001\u751f\u7d30\u80de\u3068\u5224\u5b9a\u3055\u308c\u305f\u3088\u3046\u3067\u3057\u305f\u3002\u3053\u306e\u5834\u5408\u306f\u3001\u64ae\u5f71\u5f8c\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8abf\u6574\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u306e\u660e\u308b\u3055\u306e\u95be\u5024\u3092\u8abf\u7bc0\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\uff08\u56f35\uff09\u3002<br \/>\n<div id=\"attachment_18569\" style=\"width: 663px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18569\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e4793f20cb5ee78c7c3e39ac21597192.png\" alt=\"\u56f35. Countess 3\/3 FL\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u753b\u9762\" width=\"653\" height=\"347\" class=\"size-full wp-image-18569\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e4793f20cb5ee78c7c3e39ac21597192.png 1319w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e4793f20cb5ee78c7c3e39ac21597192-300x159.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e4793f20cb5ee78c7c3e39ac21597192-1024x543.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/e4793f20cb5ee78c7c3e39ac21597192-768x408.png 768w\" sizes=\"auto, (max-width: 653px) 100vw, 653px\" \/><p id=\"caption-attachment-18569\" class=\"wp-caption-text\">\u56f35. Countess 3\/3 FL\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u753b\u9762<\/p><\/div><br \/>\n\u4ee5\u4e0a\u306e\u3053\u3068\u304b\u3089\u3001\u51e6\u740630\u5206\u306e\u5b9f\u969b\u306e\u751f\u5b58\u7387\u306f59%\u3088\u308a\u3082\u4f4e\u304b\u3063\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3042\u3048\u3066\u30c7\u30d5\u30a9\u30eb\u30c8\u8a2d\u5b9a\u3067\u6e2c\u5b9a\u3057\u307e\u3057\u305f\u304c\u3001\u5b9f\u969b\u306e\u6e2c\u5b9a\u3067\u306f\u30b5\u30f3\u30d7\u30eb\u306e\u72b6\u614b\u3092\u898b\u306a\u304c\u3089\u9069\u5207\u306b\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u8abf\u6574\u3057\u3066\u6b63\u3057\u3044\u7d50\u679c\u3092\u51fa\u529b\u3059\u308b\u3088\u3046\u306b\u5c0e\u304f\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u51e6\u740660\u5206\u3067\u751f\u5b58\u7387\u304c\u4e0a\u6607\u3057\u307e\u3057\u305f\u304c\u3001Countess\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u9069\u5207\u306b\u8abf\u6574\u3057\u3066\u3044\u308c\u3070\u3082\u3063\u3068\u4f4e\u3044\uff08\u6b63\u3057\u3044\uff09\u7d50\u679c\u304c\u5f97\u3089\u308c\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n<h2>\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u304a\u3051\u308b\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8abf\u6574\u306e\u91cd\u8981\u6027<\/h2>\n<p>\u305d\u3053\u3067\u3001Countess 3 FL\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8abf\u6574\u304c\u7d50\u679c\u306b\u3069\u306e\u7a0b\u5ea6\u5f71\u97ff\u3059\u308b\u306e\u304b\u3092\u78ba\u304b\u3081\u3066\u307f\u307e\u3057\u305f\u300260\u5206\u9593Trypsin\u51e6\u7406\u3057\u305fHeLa\u7d30\u80de\u3092\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3057\u3001\u30c7\u30d5\u30a9\u30eb\u30c8\u8a2d\u5b9a\u3068\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8abf\u6574\u5f8c\u306e\u7d50\u679c\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u56f36\u306e\u3088\u3046\u306b\u3001\u30c7\u30d5\u30a9\u30eb\u30c8\u8a2d\u5b9a\u3067\u306f\u5178\u578b\u7684\u306aHeLa\u7d30\u80de\u3088\u308a\u3082\u5c0f\u3055\u3044\u591a\u6570\u306e\u7834\u7247\u304c\u751f\u7d30\u80de\u3068\u3057\u3066\u8a8d\u8b58\u3055\u308c\u3066\u3044\u307e\u3057\u305f\uff08\u56f36\u5de6\u4e0a\uff09\u3002\u305d\u3053\u3067\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u753b\u9762\u3067\u751f\u7d30\u80de\u3068\u3057\u3066\u8a8d\u8b58\u3055\u305b\u308b\u7d30\u80de\u306e\u5927\u304d\u3055\u306e\u95be\u5024\u3092\u4e0a\u3052\u3066\u3001\u7834\u7247\u3092\u30ab\u30a6\u30f3\u30c8\u5bfe\u8c61\u304b\u3089\u9664\u5916\u3057\u307e\u3057\u305f\uff08\u56f36\u5de6\u4e0b\uff09\u3002\u305d\u306e\u7d50\u679c\u3001\u30c7\u30d5\u30a9\u30eb\u30c8\u3067\u306e\u5168\u7d30\u80de\u6fc3\u5ea6\u306f1.0 x 10<sup>6<\/sup> cells\/mL\u3001\u751f\u7d30\u80de\u7387\u306f90.8%\u3001\u751f\u7d30\u80de\u6fc3\u5ea6\u306f0.91 x 10<sup>6<\/sup> cells\/mL\u3067\u3057\u305f\u304c\u3001\u8abf\u6574\u5f8c\u306f\u5168\u7d30\u80de\u6fc3\u5ea6\u304c0.66 x 10<sup>6<\/sup> cells\/mL\u3001\u751f\u7d30\u80de\u7387\u304c85.3%\u3001\u751f\u7d30\u80de\u6fc3\u5ea6\u306f0.55 x 10<sup>6<\/sup> cells\/mL\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u306e\u5b9f\u9a13\u4f8b\u3067\u306f\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u8abf\u6574\u3092\u3057\u306a\u3044\u3068\u751f\u7d30\u80de\u306e\u6fc3\u5ea6\u3092\u5b9f\u969b\u3088\u308a\u3082\u7d041.6\u500d\u5927\u304d\u304f\u898b\u7a4d\u3082\u3063\u3066\u3057\u307e\u3046\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002<br \/>\n<div id=\"attachment_18580\" style=\"width: 566px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18580\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fdc3f49ddc9a05dc7889216eecab4537-1.png\" alt=\"\u56f36. \u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u304a\u3051\u308b\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8abf\u6574\u306e\u91cd\u8981\u6027\" width=\"556\" height=\"442\" class=\"size-full wp-image-18580\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fdc3f49ddc9a05dc7889216eecab4537-1.png 794w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fdc3f49ddc9a05dc7889216eecab4537-1-300x239.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fdc3f49ddc9a05dc7889216eecab4537-1-768x611.png 768w\" sizes=\"auto, (max-width: 556px) 100vw, 556px\" \/><p id=\"caption-attachment-18580\" class=\"wp-caption-text\">\u56f36. \u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u304a\u3051\u308b\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8abf\u6574\u306e\u91cd\u8981\u6027<\/p><\/div><br \/>\n\u306a\u304a\u3001\u3053\u306e\u3088\u3046\u306a\u3053\u3068\u304c\u8d77\u304d\u305f\u539f\u56e0\u306f\u3001Countess 3\/3FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306e\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u304c\u30c7\u30d5\u30a9\u30eb\u30c8\u3067\u306f\u6700\u5c0f4 \u03bcm\u306e\u5927\u304d\u3055\u306e\u7d30\u80de\u3092\u8a8d\u8b58\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u3068\u3057\u3066\u306f\u8840\u7403\u7cfb\u306e\u7d30\u80de\u306a\u3069\u3001HeLa\u3088\u308a\u3082\u5c0f\u3055\u306a\u7d30\u80de\u306e\u6e2c\u5b9a\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u56de\u306f\u904e\u5270\u306aTrypsin\u51e6\u7406\u3092\u3057\u305f\u6975\u7aef\u306a\u4e8b\u4f8b\u3067\u306f\u3042\u308a\u307e\u3059\u304c\u3001\u30aa\u30eb\u30ac\u30ce\u30a4\u30c9\u3092\u30b7\u30f3\u30b0\u30eb\u30bb\u30eb\u5316\u3059\u308b\u306a\u3069\u3001\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u6642\u3088\u308a\u3082\u5f37\u3044\u9175\u7d20\u51e6\u7406\u304c\u5fc5\u8981\u306a\u6642\u306b\u306f\u8003\u616e\u3059\u308b\u3068\u3088\u3044\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/p>\n<h2>\u904e\u5270\u306aTrypsin\u51e6\u7406\u3067\u7d30\u80de\u306e\u63a5\u7740\u52b9\u7387\u304c\u4f4e\u4e0b\u3059\u308b<\/h2>\n<p>\u6700\u5f8c\u306b\u3001Trypsin\u306760\u5206\u9593\u51e6\u7406\u3057\u305f\u7d30\u80de\u3092\u57f9\u990a\u30c7\u30a3\u30c3\u30b7\u30e5\u306b\u64ad\u7a2e\u3057\u3001\u4e00\u6669\u57f9\u990a\u3057\u307e\u3057\u305f\uff08\u56f37\uff09\u3002\u540c\u65e5\u306b\u64ad\u7a2e\u3057\u305f\u51e6\u74060\u5206\u306e\u7d30\u80de\u306f\u7fcc\u671d\u306b\u306f\u3057\u3063\u304b\u308a\u30c7\u30a3\u30c3\u30b7\u30e5\u5e95\u9762\u306b\u63a5\u7740\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001Trypsin\u306760\u5206\u9593\u51e6\u7406\u3055\u308c\u305f\u7d30\u80de\u306f\u3001\u4e00\u6669\u57f9\u990a\u3057\u3066\u3082\u63a5\u7740\u304c\u4e0d\u5341\u5206\u3067\u3001\u307e\u305f\u3001\u63a5\u7740\u3067\u304d\u306a\u304b\u3063\u305f\u7d30\u80de\u3082\u591a\u6570\u898b\u3089\u308c\u307e\u3057\u305f\u3002\u904e\u5270\u306aTrypsin\u51e6\u7406\u306f\u751f\u304d\u6b8b\u3063\u305f\u7d30\u80de\u306e\u305d\u306e\u5f8c\u306e\u57f9\u990a\u306b\u60aa\u5f71\u97ff\u3092\u6b8b\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002<br \/>\n<div id=\"attachment_18571\" style=\"width: 546px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18571\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/86562140caece58c89421e74f3c6180e.png\" alt=\"\u56f37. \u904e\u5270\u306bTrypsin\u51e6\u7406\u3055\u308c\u305f\u7d30\u80de\u306f\u63a5\u7740\u3057\u306b\u304f\u304f\u306a\u308b\" width=\"536\" height=\"427\" class=\"size-full wp-image-18571\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/86562140caece58c89421e74f3c6180e.png 974w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/86562140caece58c89421e74f3c6180e-300x239.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/86562140caece58c89421e74f3c6180e-768x612.png 768w\" sizes=\"auto, (max-width: 536px) 100vw, 536px\" \/><p id=\"caption-attachment-18571\" class=\"wp-caption-text\">\u56f37. \u904e\u5270\u306bTrypsin\u51e6\u7406\u3055\u308c\u305f\u7d30\u80de\u306f\u63a5\u7740\u3057\u306b\u304f\u304f\u306a\u308b<\/p><\/div><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u3001\u672c\u6765\u306f\u5fc5\u8981\u6700\u5c0f\u9650\u3068\u3059\u3079\u304d\u7d30\u80de\u3078\u306eTrypsin\u51e6\u7406\u3092\u308f\u3056\u3068\u904e\u5270\u306b\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u751f\u5b58\u7387\u306e\u4f4e\u4e0b\u3001\u7d30\u80de\u6fc3\u5ea6\u306e\u4f4e\u4e0b\u3001\u63a5\u7740\u52b9\u7387\u306e\u4f4e\u4e0b\u306a\u3069\u3001\u4e88\u60f3\u901a\u308a\u306e\u60aa\u5f71\u97ff\u304c\u78ba\u304b\u3081\u3089\u308c\u307e\u3057\u305f\u3002\u57f9\u990a\u7d30\u80de\u306e\u7d99\u4ee3\u306e\u969b\u306f\u3001\u6700\u77ed\u6642\u9593\u3067Trypsin\u51e6\u7406\u3092\u884c\u3046\u3088\u3046\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u7d30\u80de\u306e\u751f\u5b58\u7387\u3084\u6fc3\u5ea6\u306e\u6e2c\u5b9a\u306b\u30c8\u30ea\u30d1\u30f3\u30d6\u30eb\u30fc\u3068\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fcCountess 3 FL\uff08\u660e\u8996\u91ce\u30e2\u30fc\u30c9\uff09\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u304c\u3001\u6b63\u3057\u304f\u6e2c\u5b9a\u3059\u308b\u306b\u306fCountess\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3082\u5927\u4e8b\u3067\u3042\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u624b\u52d5\u3067\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3059\u308b\u6642\u306b\u306f\u3001\u898b\u3066\u3044\u308b\u3082\u306e\u304c\u6e2c\u5b9a\u3059\u3079\u304d\u7d30\u80de\u304b\u9664\u5916\u3059\u3079\u304d\u7834\u7247\u304b\u3001\u30c8\u30ea\u30d1\u30f3\u30d6\u30eb\u30fc\u306e\u67d3\u307e\u308a\u5177\u5408\u306a\u3069\u3092\u6e2c\u5b9a\u8005\u306e\u57fa\u6e96\u3067\u77ac\u6642\u306b\u5224\u65ad\u3057\u3066\u3044\u308b\u306f\u305a\u3067\u3059\u3002Countess\u3092\u4f7f\u3044\u3053\u306a\u3059\u30b3\u30c4\u306f\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u306a\u3069\u3092\u901a\u3057\u3066\u6e2c\u5b9a\u8005\u306e\u5224\u65ad\u57fa\u6e96\u3092\u81ea\u52d5\u3067\u306e\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u3069\u308c\u3060\u3051\u53cd\u6620\u3055\u305b\u3089\u308c\u308b\u304b\u3001\u3068\u8a00\u3048\u307e\u3059\u3002Countess\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u3092\u30c7\u30d5\u30a9\u30eb\u30c8\u8a2d\u5b9a\u306e\u307e\u307e\u4f7f\u7528\u4e2d\u3067\u3001\u6e2c\u5b9a\u7d50\u679c\u306b\u9055\u548c\u611f\u304c\u3042\u308b\u5834\u5408\u306f\u3001\u305c\u3072\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3092\u898b\u76f4\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u7d30\u80de\u306e\u7d99\u4ee3\u3084\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u3064\u3044\u3066\u3082\u3063\u3068\u77e5\u308a\u305f\u3044\u65b9\u306f\u7121\u6599\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/cell-culture-basic.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u3053\u308c\u304b\u3089\u59cb\u3081\u308b\u4eba\u306f\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u30ad\u30db\u30f3\u306e\u30ad<\/a>\u300d\u3001\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/cell-count-basic.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\uff01\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u3092\u57fa\u672c\u304b\u3089\u5b66\u307c\u3046<\/a>\u300d\u3084\u8b1b\u7fa9\u3068\u5b9f\u7fd2\u3067\u7d30\u80de\u57f9\u990a\u306e\u57fa\u672c\u3092\u7fd2\u5f97\u3067\u304d\u308b\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/saibo_baiyo.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">1\u65e5\u30b3\u30fc\u30b9<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/saibo-baiyo2.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">2\u65e5\u9593\u30b3\u30fc\u30b9<\/a>\uff09\u306e\u53d7\u8b1b\u3092\u3054\u691c\u8a0e\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u3089\u306e\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u306e\u5185\u5bb9\u306e\u9055\u3044\u306b\u3064\u3044\u3066\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-stem-cell-bid-ts-mbr-24038\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u95a2\u9023\u8a18\u4e8b<\/a>\u3092\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4eca\u56de\u306e\u5185\u5bb9\u306b\u9650\u3089\u305a\u3001\u7d30\u80de\u57f9\u990a\u95a2\u9023\u306e\u88fd\u54c1\u30fb\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306a\u3069\u3067\u3054\u4e0d\u660e\u70b9\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\uff08<a href=\"mailto:jptech@thermofisher.com\">jptech@thermofisher.com<\/a>\uff09\u3078\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n<h3>Gibco\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\uff082021\u5e74\u30ea\u30cb\u30e5\u30fc\u30a2\u30eb\u7248\uff09<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_workshop_bid_ts_mbr_24080_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Trypsin\u306f\u63a5\u7740\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u3067\u3059\u3002\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306e\u6d88\u5316\u4f5c\u7528\u306b\u3088\u3063\u3066\u7d30\u80de\u540c\u58eb\u306e\u63a5\u7740\u3068\u7d30\u80de\u3068\u30c7\u30a3\u30c3\u30b7\u30e5\u3068\u306e\u63a5\u7740\u306e\u89e3\u96e2\u3092\u4fc3\u3057\u307e\u3059\uff08\u95a2\u9023\u8a18\u4e8b\uff09\u3002Trypsin\u306f\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306b\u9650\u3089\u305a\u7d30\u80de\u8868\u9762\u306e<\/p>\n","protected":false},"author":975,"featured_media":18564,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[97,23],"division":[],"class_list":["post-18561","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cell","tag-cell-count","tag-cell-culture","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f\" \/>\n<meta property=\"og:description\" content=\"Trypsin\u306f\u63a5\u7740\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u3067\u3059\u3002\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306e\u6d88\u5316\u4f5c\u7528\u306b\u3088\u3063\u3066\u7d30\u80de\u540c\u58eb\u306e\u63a5\u7740\u3068\u7d30\u80de\u3068\u30c7\u30a3\u30c3\u30b7\u30e5\u3068\u306e\u63a5\u7740\u306e\u89e3\u96e2\u3092\u4fc3\u3057\u307e\u3059\uff08\u95a2\u9023\u8a18\u4e8b\uff09\u3002Trypsin\u306f\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306b\u9650\u3089\u305a\u7d30\u80de\u8868\u9762\u306e\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-20T08:17:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-12-25T06:53:22+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"667\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"14\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f\",\"datePublished\":\"2024-11-20T08:17:17+00:00\",\"dateModified\":\"2024-12-25T06:53:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/\"},\"wordCount\":150,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/41789586a8be141b64ccc0ea9cd8961b.jpg\",\"keywords\":[\"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\",\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/41789586a8be141b64ccc0ea9cd8961b.jpg\",\"datePublished\":\"2024-11-20T08:17:17+00:00\",\"dateModified\":\"2024-12-25T06:53:22+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/41789586a8be141b64ccc0ea9cd8961b.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/41789586a8be141b64ccc0ea9cd8961b.jpg\",\"width\":1000,\"height\":667},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f","og_description":"Trypsin\u306f\u63a5\u7740\u7d30\u80de\u306e\u7d99\u4ee3\u306b\u4f7f\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u5206\u89e3\u9175\u7d20\u3067\u3059\u3002\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306e\u6d88\u5316\u4f5c\u7528\u306b\u3088\u3063\u3066\u7d30\u80de\u540c\u58eb\u306e\u63a5\u7740\u3068\u7d30\u80de\u3068\u30c7\u30a3\u30c3\u30b7\u30e5\u3068\u306e\u63a5\u7740\u306e\u89e3\u96e2\u3092\u4fc3\u3057\u307e\u3059\uff08\u95a2\u9023\u8a18\u4e8b\uff09\u3002Trypsin\u306f\u7d30\u80de\u63a5\u7740\u5206\u5b50\u306b\u9650\u3089\u305a\u7d30\u80de\u8868\u9762\u306e","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-11-20T08:17:17+00:00","article_modified_time":"2024-12-25T06:53:22+00:00","og_image":[{"width":1000,"height":667,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"14\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f","datePublished":"2024-11-20T08:17:17+00:00","dateModified":"2024-12-25T06:53:22+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/"},"wordCount":150,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg","keywords":["\u7d30\u80de\u30ab\u30a6\u30f3\u30c8","\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg","datePublished":"2024-11-20T08:17:17+00:00","dateModified":"2024-12-25T06:53:22+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg","width":1000,"height":667},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-workshop-bid-ts-mbr-24080\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092Trypsin\u3067\u51e6\u7406\u3057\u3059\u304e\u3066\u307f\u305f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":97,"label":"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8"},{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg",760,507,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":104,"filter":"raw","meta":[],"cat_ID":159,"category_count":104,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":97,"name":"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8","slug":"cell-count","term_group":0,"term_taxonomy_id":97,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]},{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":65,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/41789586a8be141b64ccc0ea9cd8961b.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=18561"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18561\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/18564"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=18561"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=18561"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=18561"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=18561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}