{"id":18597,"date":"2024-11-28T15:02:52","date_gmt":"2024-11-28T06:02:52","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=18597"},"modified":"2024-11-28T15:02:52","modified_gmt":"2024-11-28T06:02:52","slug":"raman-ir-msd-24082","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/","title":{"rendered":"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf"},"content":{"rendered":"<p>\u30e9\u30de\u30f3\u5206\u5149\u6cd5\u306f\u30b5\u30f3\u30d7\u30eb\u306b\u30ec\u30fc\u30b6\u30fc\u5149\u3092\u7167\u5c04\u3057\u3001\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u5f97\u308b\u6e2c\u5b9a\u624b\u6cd5\u3067\u3059\u3002\u6e2c\u5b9a\u306e\u969b\u306b\u306f\u3001\u53ef\u8996\u50cf\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u89b3\u5bdf\u3057\u3001\u6e2c\u5b9a\u7b87\u6240\u306b\u30ec\u30fc\u30b6\u30fc\u304c\u7167\u5c04\u3055\u308c\u308b\u3088\u3046\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u76ee\u7684\u306e\u5834\u6240\u306b\u30d4\u30f3\u30dd\u30a4\u30f3\u30c8\u3067\u30ec\u30fc\u30b6\u30fc\u3092\u7167\u5c04\u3059\u308b\u305f\u3081\u3001\u306a\u308b\u3079\u304f\u30af\u30ea\u30a2\u306b\u53ef\u8996\u89b3\u5bdf\u3067\u304d\u308b\u3053\u3068\u304c\u7406\u60f3\u7684\u3067\u3059\u3002<br \/>\n<div id=\"attachment_18599\" style=\"width: 470px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18599\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04.png\" alt=\"\u56f31. DXR3\u9855\u5fae\u30e9\u30de\u30f3\" width=\"460\" height=\"289\" class=\"size-full wp-image-18599\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04.png 460w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-300x188.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-320x200.png 320w\" sizes=\"auto, (max-width: 460px) 100vw, 460px\" \/><p id=\"caption-attachment-18599\" class=\"wp-caption-text\">\u56f31. DXR3\u9855\u5fae\u30e9\u30de\u30f3<\/p><\/div><\/p>\n<h2>DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3\u306e\u89b3\u5bdf\u6a5f\u80fd\u306e\u3054\u7d39\u4ecb<\/h2>\n<p>Thermo Scientific\u2122 DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3\u306f\u660e\u8996\u91ce\u89b3\u5bdf\u304a\u3088\u3073\u6697\u8996\u91ce\u89b3\u5bdf\u304c\u53ef\u80fd\u3067\u3059\u3002\u660e\u8996\u91ce\u89b3\u5bdf\u306f\u5168\u4f53\u3092\u6bd4\u8f03\u7684\u660e\u308b\u3044\u72b6\u614b\u3067\u89b3\u5bdf\u3067\u304d\u3001\u6697\u8996\u91ce\u89b3\u5bdf\u306f\u660e\u8996\u91ce\u89b3\u5bdf\u3067\u306f\u8996\u8a8d\u3057\u306b\u304f\u3044\u51f8\u51f9\u306a\u3069\u306e\u69d8\u5b50\u3092\u898b\u3084\u3059\u304f\u89b3\u5bdf\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u30aa\u30d7\u30b7\u30e7\u30f3\u3068\u3057\u3066MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u642d\u8f09\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002MIX\u89b3\u5bdf\u306f\u660e\u8996\u91ce\u89b3\u5bdf\u3068\u6697\u8996\u91ce\u89b3\u5bdf\u306e\u7279\u5fb4\u3092\u5408\u308f\u305b\u305f\u753b\u50cf\u3092\u89b3\u5bdf\u3067\u304d\u307e\u3059\u3002\u3044\u304f\u3064\u304b\u306e\u30b5\u30f3\u30d7\u30eb\u306eMIX\u89b3\u5bdf\u753b\u50cf\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<br \/>\n<div id=\"attachment_18602\" style=\"width: 529px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18602\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/b628a91b81da56ba5a64c164f9231907.png\" alt=\"\u56f32. MIX\u89b3\u5bdf\u30aa\u30d7\u30b7\u30e7\u30f3\" width=\"519\" height=\"306\" class=\"size-full wp-image-18602\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/b628a91b81da56ba5a64c164f9231907.png 519w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/b628a91b81da56ba5a64c164f9231907-300x177.png 300w\" sizes=\"auto, (max-width: 519px) 100vw, 519px\" \/><p id=\"caption-attachment-18602\" class=\"wp-caption-text\">\u56f32. MIX\u89b3\u5bdf\u30aa\u30d7\u30b7\u30e7\u30f3<\/p><\/div> <\/p>\n<h2>\u91d1\u5c5e\u677f\u4e0a\u4ed8\u7740\u7269\u306e\u53ef\u8996\u89b3\u5bdf\u753b\u50cf<\/h2>\n<p>\u91d1\u5c5e\u677f\u4e0a\u306b\u4ed8\u7740\u7269\u304c\u898b\u3089\u308c\u3066\u3044\u308b\u30b5\u30f3\u30d7\u30eb\u306b\u3064\u3044\u3066\u3001\u2460\u660e\u8996\u91ce\u89b3\u5bdf\u3001\u2461\u6697\u8996\u91ce\u89b3\u5bdf\u3001\u2462MIX\u89b3\u5bdf\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306e\u753b\u50cf\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u6697\u8996\u91ce\u89b3\u5bdf\u304a\u3088\u3073MIX\u89b3\u5bdf\u3067\u306f\u4ed8\u7740\u3057\u3066\u3044\u308b\u7c92 \u5b50\u306a\u3069\u3092\u7acb\u4f53\u7684\u306b\u89b3\u5bdf\u3067\u304d\u307e\u3057\u305f\u3002<br \/>\n<div id=\"attachment_18603\" style=\"width: 978px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18603\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/5eb67d9170492e922e7addca8af4c342.png\" alt=\"\u56f33. \u91d1\u5c5e\u677f\u4e0a\u4ed8\u7740\u7269\u306e\u53ef\u8996\u89b3\u5bdf\u753b\u50cf\" width=\"968\" height=\"341\" class=\"size-full wp-image-18603\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/5eb67d9170492e922e7addca8af4c342.png 968w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/5eb67d9170492e922e7addca8af4c342-300x106.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/5eb67d9170492e922e7addca8af4c342-768x271.png 768w\" sizes=\"auto, (max-width: 968px) 100vw, 968px\" \/><p id=\"caption-attachment-18603\" class=\"wp-caption-text\">\u56f33. \u91d1\u5c5e\u677f\u4e0a\u4ed8\u7740\u7269\u306e\u53ef\u8996\u89b3\u5bdf\u753b\u50cf<\/p><\/div><\/p>\n<h2>\u30dd\u30ea\u30de\u30fc\u7c92\u5b50\u5206\u6563\u30d5\u30a3\u30eb\u30e0\u4e0a\u306b\u4ed8\u7740\u3057\u305f\u30a4\u30f3\u30af\u306e\u53ef\u8996\u89b3\u5bdf\u753b\u50cf<\/h2>\n<p>\u30dd\u30ea\u30de\u30fc\u7c92\u5b50\u5206\u6563\u30d5\u30a3\u30eb\u30e0\u4e0a\u306b\u30a4\u30f3\u30af\u304c\u4ed8\u7740\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u3001\u2460\u660e\u8996\u91ce\u89b3\u5bdf\u3001\u2461\u6697\u8996\u91ce\u89b3\u5bdf\u3001\u2462MIX\u89b3\u5bdf\u3067\u89b3\u5bdf\u3057\u307e\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306e\u753b\u50cf\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u660e\u8996\u91ce\u89b3\u5bdf\u3067\u306f\u8272\u306e\u9055\u3044\u304c\u306f\u3063\u304d\u308a\u3068\u308f\u304b\u308b\u753b\u50cf\u3068\u306a\u308a\u3001\u6697\u8996\u91ce\u89b3\u5bdf\u3067\u306f\u8272\u306f\u3042\u307e\u308a\u660e\u77ad\u3067\u306f\u306a\u3044\u3082\u306e\u306e\u7acb\u4f53\u7684\u306a\u753b\u50cf\u3068\u306a\u308a\u307e\u3057\u305f\u3002MIX\u89b3\u5bdf\u3067\u306f\u3001\u3053\u306e\u4e21\u65b9\u306e\u7279\u5fb4\u3092\u3082\u3064\u753b\u50cf\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<br \/>\n<div id=\"attachment_18604\" style=\"width: 974px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18604\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/cf5a9617a917b4ff86bfea7668928b2f.png\" alt=\"\u56f34. \u30dd\u30ea\u30de\u30fc\u7c92\u5b50\u5206\u6563\u30d5\u30a3\u30eb\u30e0\u4e0a\u306b\u4ed8\u7740\u3057\u305f\u30a4\u30f3\u30af\u306e\u53ef\u8996\u89b3\u5bdf\u753b\u50cf\" width=\"964\" height=\"337\" class=\"size-full wp-image-18604\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/cf5a9617a917b4ff86bfea7668928b2f.png 964w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/cf5a9617a917b4ff86bfea7668928b2f-300x105.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/cf5a9617a917b4ff86bfea7668928b2f-768x268.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/cf5a9617a917b4ff86bfea7668928b2f-960x337.png 960w\" sizes=\"auto, (max-width: 964px) 100vw, 964px\" \/><p id=\"caption-attachment-18604\" class=\"wp-caption-text\">\u56f34. \u30dd\u30ea\u30de\u30fc\u7c92\u5b50\u5206\u6563\u30d5\u30a3\u30eb\u30e0\u4e0a\u306b\u4ed8\u7740\u3057\u305f\u30a4\u30f3\u30af\u306e\u53ef\u8996\u89b3\u5bdf\u753b\u50cf<\/p><\/div><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u30e9\u30de\u30f3\u5206\u6790\u306b\u304a\u3044\u3066\u306f\u3001\u30af\u30ea\u30a2\u306a\u53ef\u8996\u89b3\u5bdf\u753b\u50cf\u304c\u5f97\u3089\u308c\u308b\u3053\u3068\u3067\u30b9\u30e0\u30fc\u30ba\u306b\u6e2c\u5b9a\u7b87\u6240\u306e\u9078\u629e\u304c\u3067\u304d\u307e\u3059\u3002DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3\u306b\u306f\u8907\u6570\u306e\u89b3\u5bdf\u6a5f\u80fd\u3092\u642d\u8f09\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u6e2c\u5b9a\u6642\u306b\u3054\u6d3b\u7528\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<h3>\u95a2\u9023\u60c5\u5831<\/h3>\n<p>\u95a2\u9023\u88fd\u54c1Web\u30da\u30fc\u30b8\u3000DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/raman-microscopy\/instruments\/dxr3-raman-microscope.html?CID=foreign_materialraman_ir_msd_24082_Social_LAB\" rel=\"noopener\" target=\"_blank\">https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/molecular-spectroscopy\/raman-microscopy\/instruments\/dxr3-raman-microscope.html<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30e9\u30de\u30f3\u5206\u5149\u6cd5\u306f\u30b5\u30f3\u30d7\u30eb\u306b\u30ec\u30fc\u30b6\u30fc\u5149\u3092\u7167\u5c04\u3057\u3001\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u5f97\u308b\u6e2c\u5b9a\u624b\u6cd5\u3067\u3059\u3002\u6e2c\u5b9a\u306e\u969b\u306b\u306f\u3001\u53ef\u8996\u50cf\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u89b3\u5bdf\u3057\u3001\u6e2c\u5b9a\u7b87\u6240\u306b\u30ec\u30fc\u30b6\u30fc\u304c\u7167\u5c04\u3055\u308c\u308b\u3088\u3046\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u76ee\u7684\u306e\u5834\u6240\u306b\u30d4\u30f3\u30dd\u30a4\u30f3\u30c8\u3067\u30ec\u30fc\u30b6\u30fc\u3092\u7167\u5c04\u3059\u308b\u305f\u3081\u3001\u306a\u308b<\/p>\n","protected":false},"author":975,"featured_media":18601,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[222,194],"division":[],"class_list":{"0":"post-18597","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-analysis","8":"tag-raman","9":"tag-ir","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf\" \/>\n<meta property=\"og:description\" content=\"\u30e9\u30de\u30f3\u5206\u5149\u6cd5\u306f\u30b5\u30f3\u30d7\u30eb\u306b\u30ec\u30fc\u30b6\u30fc\u5149\u3092\u7167\u5c04\u3057\u3001\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u5f97\u308b\u6e2c\u5b9a\u624b\u6cd5\u3067\u3059\u3002\u6e2c\u5b9a\u306e\u969b\u306b\u306f\u3001\u53ef\u8996\u50cf\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u89b3\u5bdf\u3057\u3001\u6e2c\u5b9a\u7b87\u6240\u306b\u30ec\u30fc\u30b6\u30fc\u304c\u7167\u5c04\u3055\u308c\u308b\u3088\u3046\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u76ee\u7684\u306e\u5834\u6240\u306b\u30d4\u30f3\u30dd\u30a4\u30f3\u30c8\u3067\u30ec\u30fc\u30b6\u30fc\u3092\u7167\u5c04\u3059\u308b\u305f\u3081\u3001\u306a\u308b\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-28T06:02:52+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"460\" \/>\n\t<meta property=\"og:image:height\" content=\"289\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf\",\"datePublished\":\"2024-11-28T06:02:52+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/\"},\"wordCount\":64,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/fbc1f90593a1dae96636cde40126ce04-1.png\",\"keywords\":[\"\u30e9\u30de\u30f3\u5206\u5149\u6cd5\",\"\u8d64\u5916\u5206\u5149\u6cd5\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/\",\"name\":\"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/fbc1f90593a1dae96636cde40126ce04-1.png\",\"datePublished\":\"2024-11-28T06:02:52+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/fbc1f90593a1dae96636cde40126ce04-1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/11\\\/fbc1f90593a1dae96636cde40126ce04-1.png\",\"width\":460,\"height\":289},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/raman-ir-msd-24082\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/","og_locale":"ja_JP","og_type":"article","og_title":"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf","og_description":"\u30e9\u30de\u30f3\u5206\u5149\u6cd5\u306f\u30b5\u30f3\u30d7\u30eb\u306b\u30ec\u30fc\u30b6\u30fc\u5149\u3092\u7167\u5c04\u3057\u3001\u30e9\u30de\u30f3\u30b9\u30da\u30af\u30c8\u30eb\u3092\u5f97\u308b\u6e2c\u5b9a\u624b\u6cd5\u3067\u3059\u3002\u6e2c\u5b9a\u306e\u969b\u306b\u306f\u3001\u53ef\u8996\u50cf\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u89b3\u5bdf\u3057\u3001\u6e2c\u5b9a\u7b87\u6240\u306b\u30ec\u30fc\u30b6\u30fc\u304c\u7167\u5c04\u3055\u308c\u308b\u3088\u3046\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u76ee\u7684\u306e\u5834\u6240\u306b\u30d4\u30f3\u30dd\u30a4\u30f3\u30c8\u3067\u30ec\u30fc\u30b6\u30fc\u3092\u7167\u5c04\u3059\u308b\u305f\u3081\u3001\u306a\u308b","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-11-28T06:02:52+00:00","og_image":[{"width":460,"height":289,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf","datePublished":"2024-11-28T06:02:52+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/"},"wordCount":64,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png","keywords":["\u30e9\u30de\u30f3\u5206\u5149\u6cd5","\u8d64\u5916\u5206\u5149\u6cd5"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/","name":"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png","datePublished":"2024-11-28T06:02:52+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png","width":460,"height":289},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/raman-ir-msd-24082\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"Thermo Scientific DXR3\u9855\u5fae\u30ec\u30fc\u30b6\u30fc\u30e9\u30de\u30f3 MIX\u89b3\u5bdf\u6a5f\u80fd\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u53ef\u8996\u50cf\u89b3\u5bdf"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":222,"label":"\u30e9\u30de\u30f3\u5206\u5149\u6cd5"},{"value":194,"label":"\u8d64\u5916\u5206\u5149\u6cd5"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png",460,289,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":105,"filter":"raw","meta":[],"cat_ID":157,"category_count":105,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":222,"name":"\u30e9\u30de\u30f3\u5206\u5149\u6cd5","slug":"raman","term_group":0,"term_taxonomy_id":222,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":194,"name":"\u8d64\u5916\u5206\u5149\u6cd5","slug":"ir","term_group":0,"term_taxonomy_id":194,"taxonomy":"post_tag","description":"","parent":0,"count":15,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/11\/fbc1f90593a1dae96636cde40126ce04-1.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18597","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=18597"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18597\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/18601"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=18597"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=18597"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=18597"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=18597"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}