{"id":18677,"date":"2024-12-17T16:42:23","date_gmt":"2024-12-17T07:42:23","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=18677"},"modified":"2024-12-17T16:42:23","modified_gmt":"2024-12-17T07:42:23","slug":"sanger-seq-ce-4-gsd-ts-ce-24086","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/","title":{"rendered":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf"},"content":{"rendered":"<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u3088\u308a\u89e3\u8aad\u3067\u304d\u305f\u9577\u3055\u304c\u4e88\u60f3\u3088\u308a\u77ed\u3044\u5834\u5408\u3001\u3055\u307e\u3056\u307e\u306a\u539f\u56e0\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3088\u308a\u9577\u304f\u89e3\u8aad\u3059\u308b\u305f\u3081\u306e\u5bfe\u51e6\u6cd5\u306f\u3001\u539f\u56e0\u306b\u3088\u308a\u7570\u306a\u308b\u305f\u3081\u3001\u307e\u305aRaw Data\u3092\u78ba\u8a8d\u3057\u3001\u539f\u56e0\u3092\u8003\u5bdf\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002Applied Biosystems\u2122 Sequencing Analysis\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306eRaw Data\u306e\u78ba\u8a8d\u624b\u9806\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-gsd-ts-ce-24024\/?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_4_gsd_ts_ce_24086_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u3053\u3061\u3089<\/a>\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<br \/>\n\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001Raw Data\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u4e88\u60f3\u3088\u308a\u65e9\u3044\u6bb5\u968e\u3067\u30c9\u30ed\u30c3\u30d7\u3057\u305f\u5834\u5408\u3068\u3001\u6ce2\u5f62\u5e8f\u76e4\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u9ad8\u304f\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u306a\u72b6\u614b\u3068\u306a\u3063\u305f\u5834\u5408\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u6ce2\u5f62\u306e\u9014\u4e2d\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u30c9\u30ed\u30c3\u30d7\u3057\u3066\u3044\u308b<\/h2>\n<p>Raw Data\u306e\u30b7\u30b0\u30ca\u30eb\u304c\u4e88\u60f3\u3088\u308a\u65e9\u3044\u6bb5\u968e\u3067\u30c9\u30ed\u30c3\u30d7\u3057\u305f\u5834\u5408\uff08\u56f31\uff09\u3001\u89e3\u6790\u9818\u57df\u306e\u5869\u57fa\u914d\u5217\u304c\u539f\u56e0\u3067DNA\u306e\u4f38\u9577\u304c\u505c\u6b62\u3057\u305f\u53ef\u80fd\u6027\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u71b1\u51e6\u7406\u3084\u5909\u6027\u5264\u306e\u6dfb\u52a0\u306a\u3069\u304c\u5bfe\u51e6\u6cd5\u3068\u306a\u308a\u307e\u3059\u3002\u4e0b\u8868\u306b\u3001\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u3092\u307e\u3068\u3081\u307e\u3059\u3002<br \/>\n<div id=\"attachment_18679\" style=\"width: 2570px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18679\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/6faa239fef226e7f45e6b628bfeb0b4b-scaled.jpg\" alt=\"\u56f31. \u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u6025\u6fc0\u306b\u4f4e\u4e0b\u3057\u305f\u30c7\u30fc\u30bf\u4f8b \uff08Raw Data\uff09\" width=\"2560\" height=\"740\" class=\"size-full wp-image-18679\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/6faa239fef226e7f45e6b628bfeb0b4b-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/6faa239fef226e7f45e6b628bfeb0b4b-300x87.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/6faa239fef226e7f45e6b628bfeb0b4b-1024x296.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/6faa239fef226e7f45e6b628bfeb0b4b-768x222.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/6faa239fef226e7f45e6b628bfeb0b4b-1536x444.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/6faa239fef226e7f45e6b628bfeb0b4b-2048x592.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><p id=\"caption-attachment-18679\" class=\"wp-caption-text\">\u56f31. \u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u6025\u6fc0\u306b\u4f4e\u4e0b\u3057\u305f\u30c7\u30fc\u30bf\u4f8b \uff08Raw Data\uff09<\/p><\/div><\/p>\n<table>\n<tbody style=\"border-bottom: none\">\n<tr bgcolor=\"silver\">\n<td style=\"text-align: center\" width=\"300\"><b>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0<\/b><\/td>\n<td style=\"text-align: center\" width=\"400\"><b>\u5bfe\u51e6\u6cd5<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"300\">\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306b\u304a\u3044\u3066\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u7279\u5b9a\u9818\u57df\u3067\u3001DNA \u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306b\u3088\u308bDNA\u306e\u4f38\u9577\u304c\u505c\u6b62\u3057\u305f<\/td>\n<td style=\"text-align: left\" width=\"400\">\n<ul>\n<li>\u30d8\u30a2\u30d4\u30f3\u306a\u3069\u306e\u4e8c\u6b21\u69cb\u9020\u304c\u539f\u56e0\u306e\u5834\u5408\u3001\u554f\u984c\u306e\u9818\u57df\u5468\u8fba\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u518d\u8a2d\u8a08\u3059\u308b\u3002\u6dfb\u52a0\u5264\uff085\uff5e10% DMSO\u3084\u30d9\u30bf\u30a4\u30f3\u3001\u30b0\u30ea\u30bb\u30ed\u30fc\u30eb\u306a\u3069\uff09\u306e\u4f7f\u7528\u3084\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u6700\u521d\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u30921\u5206\u304b\u308910\u5206\u306b\u5ef6\u9577\u3059\u308b\u3053\u3068\u3067\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u5909\u6027\u304c\u4fc3\u9032\u3055\u308c\u308b\u3068\u306e\u5831\u544a\u3082\u3042\u308b<sup>\u203b1<\/sup><\/li>\n<li>G\u30ea\u30c3\u30c1\u306a\u5869\u57fa\u914d\u5217\u306e\u5834\u5408\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4307175?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_4_gsd_ts_ce_24086_Social_LAB\" rel=\"noopener\" target=\"_blank\">Applied Biosystems\u2122 dGTP BigDye\u2122 Terminator Ready Reaction Cycle Sequencing Kit<\/a>\u306e\u4f7f\u7528\u3082\u9078\u629e\u80a2\u306e\u3072\u3068\u3064<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"300\">\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306b\u4f7f\u7528\u3057\u305fApplied Biosystems\u2122 BigDye\u2122 Terminator Ready Reaction Mix\u306e\u91cf\u304c\u5c11\u306a\u3044<\/td>\n<td style=\"text-align: left\" width=\"400\">BigDye Terminator Ready Reaction Mix\u3092\u5e0c\u91c8\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u6a19\u6e96\u30d7\u30ed\u30c8\u30b3\u30eb\u3078\u623b\u3059<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"300\">\u203b1 \u5f53\u793e\u3067\u306e\u30c6\u30b9\u30c8\u306f\u5b9f\u65bd\u3057\u3066\u304a\u308a\u307e\u305b\u3093\u3002<\/td>\n<td style=\"text-align: left\" width=\"400\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf<\/h2>\n<p>Raw Data\u306e\u6700\u521d\u304b\u3089\u5f8c\u534a\u306b\u5411\u304b\u3044\u5f90\u3005\u306b\u30d4\u30fc\u30af\u9ad8\u3055\u304c\u4f4e\u4e0b\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u6db2\u306e\u7d44\u6210\u304c\u9069\u5207\u3067\u306a\u3044\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n<div id=\"attachment_18681\" style=\"width: 2570px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18681\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/f4ec69db6bac07842e89ffb62b684980-scaled.jpg\" alt=\"\u56f32. \u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u5f90\u3005\u306b\u4f4e\u4e0b\u3057\u305f\u30c7\u30fc\u30bf\u4f8b \uff08Raw Data\uff09\" width=\"2560\" height=\"830\" class=\"size-full wp-image-18681\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/f4ec69db6bac07842e89ffb62b684980-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/f4ec69db6bac07842e89ffb62b684980-300x97.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/f4ec69db6bac07842e89ffb62b684980-1024x332.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/f4ec69db6bac07842e89ffb62b684980-768x249.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/f4ec69db6bac07842e89ffb62b684980-1536x498.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/f4ec69db6bac07842e89ffb62b684980-2048x664.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><p id=\"caption-attachment-18681\" class=\"wp-caption-text\">\u56f32. \u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u304c\u5f90\u3005\u306b\u4f4e\u4e0b\u3057\u305f\u30c7\u30fc\u30bf\u4f8b \uff08Raw Data\uff09<\/p><\/div><\/p>\n<table>\n<tbody>\n<tr bgcolor=\"silver\">\n<td style=\"text-align: center\" width=\"300\"><b>\u4e88\u6e2c\u3055\u308c\u308b\u539f\u56e0<\/b><\/td>\n<td style=\"text-align: left\" width=\"10\">\u3000<\/td>\n<td style=\"text-align: center\" width=\"400\"><b>\u5bfe\u51e6\u6cd5<\/b><\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"300\">\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306e\u4f38\u9577\u6642\u9593\u304c\u77ed\u3044\u3001\u307e\u305f\u306f\u4f38\u9577\u6e29\u5ea6\u304c\u9ad8\u3044<\/td>\n<td style=\"text-align: left\" width=\"10\">\u3000<\/td>\n<td style=\"text-align: left\" width=\"400\">\u4f38\u9577\u6642\u9593\u3092\u5ef6\u3070\u3059\u304b\u3001\u4f38\u9577\u6e29\u5ea6\u3092\u4e0b\u3052\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"300\">\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u53cd\u5fdc\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u5bfe\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u6bd4\u7387\u304c\u4e0d\u9069\u5207<\/td>\n<td style=\"text-align: left\" width=\"10\">\u3000<\/td>\n<td style=\"text-align: left\" width=\"400\">\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u5bfe\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u6bd4\u7387\u3092\u691c\u8a0e\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"300\">\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306b\u3001DNA \u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u6d3b\u6027\u3092\u963b\u5bb3\u3059\u308b\u3082\u306e\u304c\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3057\u3066\u3044\u308b<\/td>\n<td style=\"text-align: left\" width=\"10\">\u3000<\/td>\n<td style=\"text-align: left\" width=\"400\">\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u306e\u8abf\u88fd\u65b9\u6cd5\u3092\u78ba\u8a8d\u3057\u3001\u5225\u306e\u65b9\u6cd5\u3092\u8a66\u3059\u304b\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3092\u7cbe\u88fd\u3059\u308b<\/td>\n<\/tr>\n<tr>\n<td style=\"text-align: left\" width=\"300\">\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u306b\u4f7f\u7528\u3057\u305fBigDye Terminator Ready Reaction Mix\u306e\u91cf\u304c\u5c11\u306a\u3044<\/td>\n<td style=\"text-align: left\" width=\"10\">\u3000<\/td>\n<td style=\"text-align: left\" width=\"400\">BigDye Terminator Ready Reaction Mix\u3092\u5e0c\u91c8\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u6a19\u6e96\u30d7\u30ed\u30c8\u30b3\u30eb\u3078\u623b\u3059<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Raw Data\u304c\u3001\u56f33\u306b\u793a\u3059\u3088\u3046\u306a\u6ce2\u5f62\u3068\u306a\u3063\u3066\u3044\u308b\u5834\u5408\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u53cd\u5fdc\u3067\u3001\u77ed\u3044\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u304c\u512a\u5148\u7684\u306b\u751f\u6210\u3055\u308c\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u77ed\u3044\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u306f\u3001\u30c6\u30f3\u30d7\u30ec\u30fc\u30c8\u3068\u3057\u305fPCR\u7523\u7269\u4e2d\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u306b\u8d77\u56e0\u3059\u308b\u3053\u3068\u304c\u61f8\u5ff5\u3055\u308c\u308b\u305f\u3081\u3001PCR\u30d7\u30e9\u30a4\u30de\u30fc\u3092\u518d\u8a2d\u8a08\u3057\u3001\u30d7\u30e9\u30a4\u30de\u30fc\u30c0\u30a4\u30de\u30fc\u304c\u5f62\u6210\u3055\u308c\u308b\u30c7\u30b6\u30a4\u30f3\u3092\u9664\u5916\u3059\u308b\u3053\u3068\u304c\u5bfe\u51e6\u6cd5\u3068\u306a\u308a\u307e\u3059\u3002<br \/>\n<div id=\"attachment_18682\" style=\"width: 2570px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-18682\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/bc16be35435cd554eb846eb1909002de-scaled.jpg\" alt=\"\u56f33. \u77ed\u3044\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u304c\u512a\u5148\u7684\u306b\u751f\u6210\u3057\u305f\u5834\u5408\u306e\u30c7\u30fc\u30bf\u4f8b \uff08Raw Data\uff09\" width=\"2560\" height=\"686\" class=\"size-full wp-image-18682\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/bc16be35435cd554eb846eb1909002de-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/bc16be35435cd554eb846eb1909002de-300x80.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/bc16be35435cd554eb846eb1909002de-1024x274.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/bc16be35435cd554eb846eb1909002de-768x206.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/bc16be35435cd554eb846eb1909002de-1536x411.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/12\/bc16be35435cd554eb846eb1909002de-2048x549.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><p id=\"caption-attachment-18682\" class=\"wp-caption-text\">\u56f33. \u77ed\u3044\u30b7\u30fc\u30b1\u30f3\u30b9\u7523\u7269\u304c\u512a\u5148\u7684\u306b\u751f\u6210\u3057\u305f\u5834\u5408\u306e\u30c7\u30fc\u30bf\u4f8b \uff08Raw Data\uff09<\/p><\/div><\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u4eca\u56de\u306f\u3001\u30b7\u30b0\u30ca\u30eb\u304c\u4e88\u60f3\u3088\u308a\u65e9\u304f\u30c9\u30ed\u30c3\u30d7\u3057\u305f\u5834\u5408\u3068\u3001\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf\u3068\u306a\u3063\u305f\u5834\u5408\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u5bfe\u51e6\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u7d50\u679c\u3001\u89e3\u8aad\u3067\u304d\u305f\u9577\u3055\u304c\u60f3\u5b9a\u3088\u308a\u77ed\u3044\u3068\u304d\u306f\u3001\u672c\u30d6\u30ed\u30b0\u306e\u5185\u5bb9\u3092\u53c2\u8003\u306b\u3057\u3066\u3044\u305f\u3060\u3051\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308b\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u3064\u3044\u3066\u3001\u3088\u308a\u8a73\u3057\u304f\u77e5\u308a\u305f\u3044\u65b9\u306f\u3001\u4e0b\u8a18\u3088\u308a\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u57fa\u672c\u539f\u5247\u3092\u5b66\u3079\u308b\u8cc7\u6599\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n<h3>\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3000\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/sanger-sequencing-guide-download.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_4_gsd_ts_ce_24086_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sequencing-learning-center.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_4_gsd_ts_ce_24086_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u30e9\u30fc\u30cb\u30f3\u30b0\u30bb\u30f3\u30bf\u30fc<\/a>\u304b\u3089\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u95a2\u3059\u308b\u5404\u7a2e\u6280\u8853\u60c5\u5831\u306b\u30a2\u30af\u30bb\u30b9\u3044\u305f\u3060\u304f\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u57fa\u790e\u30bb\u30df\u30ca\u30fc\u3084\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3082\u3054\u3056\u3044\u307e\u3059\u306e\u3067\u3001\u305c\u3072\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/dna-sequencing.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_4_gsd_ts_ce_24086_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u57fa\u790e\u30bb\u30df\u30ca\u30fc\uff081\uff09\u57fa\u672c\u539f\u7406<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/dna-sequencing2.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_4_gsd_ts_ce_24086_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u57fa\u790e\u30bb\u30df\u30ca\u30fc\uff082\uff09\u30c7\u30fc\u30bf\u78ba\u8a8d\u3068\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8<\/a><br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/ab-dna-sequencing3130-3130xL.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_ce_4_gsd_ts_ce_24086_Social_LAB\" rel=\"noopener\" target=\"_blank\">\u5b8c\u5168\u30de\u30b9\u30bf\u30fc\uff01\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30b3\u30fc\u30b9\u3000\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\uff081\uff09 \u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u304b\u3089\u30c7\u30fc\u30bf\u78ba\u8a8d\u307e\u3067<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u3088\u308a\u89e3\u8aad\u3067\u304d\u305f\u9577\u3055\u304c\u4e88\u60f3\u3088\u308a\u77ed\u3044\u5834\u5408\u3001\u3055\u307e\u3056\u307e\u306a\u539f\u56e0\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3088\u308a\u9577\u304f\u89e3\u8aad\u3059\u308b\u305f\u3081\u306e\u5bfe\u51e6\u6cd5\u306f\u3001\u539f\u56e0\u306b\u3088\u308a\u7570\u306a\u308b\u305f\u3081\u3001\u307e\u305aRaw Data\u3092\u78ba\u8a8d\u3057\u3001\u539f\u56e0\u3092\u8003\u5bdf\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002Applied Bio<\/p>\n","protected":false},"author":975,"featured_media":18175,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[172,183],"division":[],"class_list":{"0":"post-18677","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-ce","9":"tag-sanger-seq","10":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf\" \/>\n<meta property=\"og:description\" content=\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u3088\u308a\u89e3\u8aad\u3067\u304d\u305f\u9577\u3055\u304c\u4e88\u60f3\u3088\u308a\u77ed\u3044\u5834\u5408\u3001\u3055\u307e\u3056\u307e\u306a\u539f\u56e0\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3088\u308a\u9577\u304f\u89e3\u8aad\u3059\u308b\u305f\u3081\u306e\u5bfe\u51e6\u6cd5\u306f\u3001\u539f\u56e0\u306b\u3088\u308a\u7570\u306a\u308b\u305f\u3081\u3001\u307e\u305aRaw Data\u3092\u78ba\u8a8d\u3057\u3001\u539f\u56e0\u3092\u8003\u5bdf\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002Applied Bio\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-17T07:42:23+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1351\" \/>\n\t<meta property=\"og:image:height\" content=\"1356\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf\",\"datePublished\":\"2024-12-17T07:42:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/\"},\"wordCount\":84,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"keywords\":[\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5\",\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/\",\"name\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"datePublished\":\"2024-12-17T07:42:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2024\\\/09\\\/0e97e4007672f35cab08c05598910782.jpg\",\"width\":1351,\"height\":1356},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-ce-4-gsd-ts-ce-24086\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf","og_description":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u3088\u308a\u89e3\u8aad\u3067\u304d\u305f\u9577\u3055\u304c\u4e88\u60f3\u3088\u308a\u77ed\u3044\u5834\u5408\u3001\u3055\u307e\u3056\u307e\u306a\u539f\u56e0\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3088\u308a\u9577\u304f\u89e3\u8aad\u3059\u308b\u305f\u3081\u306e\u5bfe\u51e6\u6cd5\u306f\u3001\u539f\u56e0\u306b\u3088\u308a\u7570\u306a\u308b\u305f\u3081\u3001\u307e\u305aRaw Data\u3092\u78ba\u8a8d\u3057\u3001\u539f\u56e0\u3092\u8003\u5bdf\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002Applied Bio","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2024-12-17T07:42:23+00:00","og_image":[{"width":1351,"height":1356,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf","datePublished":"2024-12-17T07:42:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/"},"wordCount":84,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","keywords":["\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/","name":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","datePublished":"2024-12-17T07:42:23+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","width":1351,"height":1356},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-ce-4-gsd-ts-ce-24086\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c8\uff1a\u30b7\u30b0\u30ca\u30eb\u306e\u30c9\u30ed\u30c3\u30d7\u3068\u30c8\u30c3\u30d7\u30d8\u30d3\u30fc\u30c7\u30fc\u30bf"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":172,"label":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5"},{"value":183,"label":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782-1020x1024.jpg",760,763,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":172,"name":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u96fb\u6c17\u6cf3\u52d5","slug":"ce","term_group":0,"term_taxonomy_id":172,"taxonomy":"post_tag","description":"","parent":0,"count":34,"filter":"raw","meta":[]},{"term_id":183,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","slug":"sanger-seq","term_group":0,"term_taxonomy_id":183,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2024\/09\/0e97e4007672f35cab08c05598910782.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18677","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=18677"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18677\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/18175"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=18677"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=18677"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=18677"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=18677"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}