{"id":18873,"date":"2025-01-21T14:52:41","date_gmt":"2025-01-21T05:52:41","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=18873"},"modified":"2025-01-21T15:58:51","modified_gmt":"2025-01-21T06:58:51","slug":"protein-expression-cloning-3-bid-ts-mbr-25003","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/","title":{"rendered":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61"},"content":{"rendered":"<p>\u3055\u3066\u3001\u7b2c3\u56de\u3067\u3059\u3002\u6700\u7d42\u56de\u306e\u4e88\u5b9a\u3067\u3057\u305f\u304c\u3001\u5c11\u3057\u9577\u304f\u306a\u3063\u305f\u306e\u30672\u56de\u306b\u5206\u3051\u308b\u3053\u3068\u306b\u3044\u305f\u3057\u307e\u3057\u305f\u3002\u6b21\u56de\u306e\u5b9f\u4f8b\u96c62\u304c\u6700\u7d42\u56de\u3068\u306a\u308b\u306f\u305a\u3067\u3059\u3002\u3088\u308d\u3057\u3051\u308c\u3070\u3082\u3046\u5c11\u3057\u304a\u4ed8\u304d\u5408\u3044\u304f\u3060\u3055\u3044\u3002<br \/>\n2\u56de\u306b\u308f\u305f\u308a\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092\u8aac\u660e\u3057\u307e\u3059\u3002\u4f9b\u7d66\u5143\uff08\u30e1\u30fc\u30ab\u30fc\u3084\u7814\u7a76\u8005\u306a\u3069\uff09\u306b\u805e\u3051\u308c\u3070\u3044\u3044\u306e\u3067\u3059\u304c\u3001\u3082\u308d\u3082\u308d\u5927\u4eba\u306e\u4e8b\u60c5\u3067\u805e\u304f\u306e\u304c\u96e3\u3057\u3044\u3053\u3068\u3082\u3042\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u305d\u3093\u306a\u6642\u306e\u305f\u3081\u306b\u3053\u306e\u30d6\u30ed\u30b0\u3092\u66f8\u3044\u3066\u3044\u307e\u3059\u3002\u5c11\u3057\u3067\u3082\u304a\u5f79\u306b\u7acb\u3066\u305f\u3089\u5e78\u3044\u3067\u3059\u3002\u306a\u304a\u3001\u3068\u3053\u308d\u3069\u3053\u308d\u88dc\u8db3\u8aac\u660e\u3092\u5165\u308c\u307e\u3059\u304c\u3001\u3082\u3057\u3053\u306e\u8a18\u4e8b\u3060\u3051\u3067\u5206\u304b\u308a\u306b\u304f\u3044\u3068\u3053\u308d\u304c\u3042\u308c\u3070<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-bid-ts-1\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">\u7b2c1\u56de<\/a>\u30fb<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-2-bid-ts-mbr-24076\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">\u7b2c2\u56de<\/a>\u306e\u8a18\u4e8b\u3092\u898b\u76f4\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<br \/>\n\u6700\u521d\u306b\u5fa9\u7fd2\u3082\u517c\u306d\u3066\u4e00\u822c\u7684\u306a\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u3069\u306e\u3088\u3046\u306a\u30a8\u30ec\u30e1\u30f3\u30c8\u304c\u542b\u307e\u308c\u308b\u304b\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u5e7e\u3064\u304b\u5225\u306e\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u624b\u9806\u3092\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u3064\u3044\u3066<\/h2>\n<p>\u4e00\u822c\u7684\u306a\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc\u306e\u30de\u30c3\u30d7\uff08\u4ee5\u4e0b\uff09\u3092\u4f8b\u306b\u3001\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/90146ca85070b45cca5bc52525e51775.png\" alt=\"\" width=\"481\" height=\"498\" class=\"aligncenter size-full wp-image-18876\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/90146ca85070b45cca5bc52525e51775.png 572w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/90146ca85070b45cca5bc52525e51775-289x300.png 289w\" sizes=\"auto, (max-width: 481px) 100vw, 481px\" \/><br \/>\n\u307e\u305a\u3001\u591a\u304f\u306e\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306f\u4e0a\u8a18\u306e\u3088\u3046\u306b\uff08\u30a2\uff09\u30fb\uff08\u30a4\uff09\u30fb\uff08\u30a6\uff09\u306e3\u3064\u306e\u9818\u57df\u306b\u5206\u3051\u3089\u308c\u307e\u3059\u3002<br \/>\n\uff08\u30a2\uff09\u5927\u8178\u83cc\u5185\u3067\u306e\u30d9\u30af\u30bf\u30fc\u306e\u8907\u88fd\u30fb\u7dad\u6301\u306b\u95a2\u308f\u308b\u9818\u57df<br \/>\n\uff08\u30a4\uff09\u76ee\u7684\u907a\u4f1d\u5b50\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u767a\u73fe\u306b\u95a2\u308f\u308b\u9818\u57df<br \/>\n\uff08\u30a6\uff09\u305d\u306e\u4ed6\u5927\u8178\u83cc\u4ee5\u5916\u306e\u751f\u7269\u5185\u3067\u306e\u6a5f\u80fd\uff08\u9078\u5225\u30fb\u30b2\u30ce\u30e0\u3078\u306e\u7d44\u307f\u8fbc\u307f\u306a\u3069\uff09\u306b\u95a2\u308f\u308b\u9818\u57df<\/p>\n<p>\uff08\u30a2\uff09\u306b\u306f\u5927\u8178\u83cc\u5185\u3067\u306e\u30d7\u30e9\u30b9\u30df\u30c9\u30d9\u30af\u30bf\u30fc\u306e\u8907\u88fd\u306b\u95a2\u308f\u308borigin\uff08\u2460\uff09\u3001\u5927\u8178\u83cc\u5185\u3067\u767a\u73fe\u30fb\u6a5f\u80fd\u3059\u308b\u6297\u751f\u7269\u8cea\u8010\u6027\u907a\u4f1d\u5b50\uff08\u2461\uff09\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u306a\u304a\u3001\u2461\u306e\u5468\u8fba\u306b\u306f\u5927\u8178\u83cc\u5185\u3067\u306e\u767a\u73fe\u306b\u5fc5\u8981\u306a\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3084\u30bf\u30fc\u30df\u30cd\u30fc\u30bf\u30fc\u306a\u3069\u306e\u30a8\u30ec\u30e1\u30f3\u30c8\u304c\u5fc5\u9808\u3067\u3059\u304c\u3001\u8a18\u8f09\u304c\u7701\u7565\u3055\u308c\u3066\u3044\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u3002<\/p>\n<p>\uff08\u30a4\uff09\u306b\u306f\u76ee\u7684\u907a\u4f1d\u5b50\u3092\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3059\u308b\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\uff08\u2463\uff09\u3068\u3001\u305d\u306e\u4e21\u7aef\u306b\u76ee\u7684\u907a\u4f1d\u5b50\u306e\u8ee2\u5199\u30fb\u7ffb\u8a33\u306b\u4fc2\u308f\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\uff08\u2462\uff1a\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3001\u2465\uff1a\u30dd\u30eaA \u4ed8\u52a0\u30b7\u30b0\u30ca\u30eb\u306a\u3069\uff09\u304c\u914d\u7f6e\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u8fd1\u8fba\u306b\u306f\u878d\u5408\u30bf\u30b0\u914d\u5217\uff08\u2464\uff09\u3084\u30b7\u30fc\u30b1\u30f3\u30b9\u7528\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u30b5\u30a4\u30c8\uff08\u2466\uff09\u304c\u5b58\u5728\u3059\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u306a\u304a\u3001\u771f\u6838\u751f\u7269\uff08\u54fa\u4e73\u985e\u3001\u6606\u866b\u3001\u9175\u6bcd\u306a\u3069\uff09\u3068\u539f\u6838\u751f\u7269\uff08\u5927\u8178\u83cc\u306a\u3069\uff09\u3067\u8ee2\u5199\u30fb\u7ffb\u8a33\u306b\u5fc5\u8981\u306a\u30a8\u30ec\u30e1\u30f3\u30c8\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u8a73\u3057\u304f\u306f<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-bid-ts-1?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">\u7b2c1\u56de<\/a>\u306e\u300c2. \u8ee2\u5199\u3001\u7ffb\u8a33\u95a2\u9023\u30a8\u30ec\u30e1\u30f3\u30c8\u300d\u306b\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\uff08\u30a6\uff09\u306b\u306f\u54fa\u4e73\u985e\u7d30\u80de\u30fb\u6606\u866b\u7d30\u80de\u306a\u3069\u5927\u8178\u83cc\u4ee5\u5916\u306e\u5bbf\u4e3b\u5185\u3067\u767a\u73fe\u3059\u308b\u6297\u751f\u7269\u8cea\u8010\u6027\u907a\u4f1d\u5b50\uff08\u2467\uff09\u3001\u304a\u3088\u3073\u305d\u306e\u907a\u4f1d\u5b50\u306e\u767a\u73fe\u306b\u95a2\u308f\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\uff08\u2468\uff1a\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3001\u2469\uff1a\u30dd\u30eaA\u4ed8\u52a0\u30b7\u30b0\u30ca\u30eb\u306a\u3069\uff09\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u306a\u304a\u3001\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u306f\u8010\u6027\u907a\u4f1d\u5b50\u306e\u4e0a\u6d41\u306b\u5927\u8178\u83cc\u5185\u3067\u6a5f\u80fd\u3059\u308bEM7\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\uff08\u246a\uff09\u304c\u633f\u5165\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001bsd\uff08\u30d6\u30e9\u30b9\u30c8\u30b7\u30b8\u30f3\u8010\u6027\u907a\u4f1d\u5b50\uff09\u306f\u5927\u8178\u83cc\u5185\u3067\u3082\u767a\u73fe\u30fb\u6a5f\u80fd\u3057\u307e\u3059\u3002\u3088\u3063\u3066\u3001\u5f62\u8cea\u8ee2\u63db\u5f8c\u306e\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u3060\u3051\u3067\u306a\u304f\u30d6\u30e9\u30b9\u30c8\u30b7\u30b8\u30f3\u3082\u4f7f\u3048\u307e\u3059\u3002\u305d\u306e\u4ed6\u30d9\u30af\u30bf\u30fc\u306e\u30b2\u30ce\u30e0\uff08\u5927\u8178\u83cc\u4ee5\u5916\uff09\u3078\u306e\u7d44\u307f\u8fbc\u307f\u306b\u95a2\u308f\u308b\u914d\u5217\u3082\u3053\u3053\u306b\u5206\u985e\u3059\u308b\u3053\u3068\u306b\u3057\u307e\u3059\u3002<\/p>\n<p>\u306a\u304a\u3001\uff08\u30a4\uff09\u306e\u9818\u57df\u306b\u201c\u30b3\u30f3\u30bf\u30df\u201d\u3057\u3066\u3044\u308bf1 ori\uff08\u246b\uff09\u3067\u3059\u304c\u3001\u3053\u306e\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u6a5f\u80fd\u304c\u5229\u7528\u3055\u308c\u308b\u3053\u3068\u306f\u307b\u3068\u3093\u3069\u3042\u308a\u307e\u305b\u3093\u306e\u3067\u7121\u8996\u3057\u3066\u3082\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-2-bid-ts-mbr-24076\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">\u7b2c2\u56de<\/a>\u306e\u30a8\u30ec\u30e1\u30f3\u30ea\u30b9\u30c8\u3067f1 ori\u306b\u3064\u3044\u3066\u7c21\u5358\u306b\u8aac\u660e\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u6c17\u306b\u306a\u308b\u65b9\u306f\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u5404\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u6a5f\u80fd\u306b\u3064\u3044\u3066\u3082\u3046\u5c11\u3057\u5fa9\u7fd2\u3055\u308c\u305f\u3044\u65b9\u306f\u672c\u30b7\u30ea\u30fc\u30ba<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-bid-ts-1?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">\u7b2c1\u56de<\/a>\u306e1\uff5e3\u9805\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n<h2>\u4f8b1\uff1a\u4e00\u822c\u7684\u306a\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u30d9\u30af\u30bf\u30fc\uff08\u76ee\u7684\u907a\u4f1d\u5b50\u633f\u5165\u524d\uff09<\/h2>\n<p>\u6b21\u306b\u3001\u5148\u7a0b\u306e\u4f8b\u3068\u3088\u304f\u4f3c\u3066\u3044\u307e\u3059\u304c\u4e00\u822c\u7684\u306a\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc\uff08\u907a\u4f1d\u5b50\u633f\u5165\u524d\uff09\u306e\u30de\u30c3\u30d7\u3092\u4f8b\u306b\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u89e3\u8aad\u306e\u624b\u9806\u3092\u8aac\u660e\u3057\u307e\u3059\u3002\u4f8b\u984c\u306e\u30de\u30c3\u30d7\u306f\u4ee5\u4e0b\u3067\u3059\u304c\u3001\uff08\u30a2\uff09\u30fb\uff08\u30a4\uff09\u30fb\uff08\u30a6\uff09\u306e\u9818\u57df\u306b\u5206\u985e\u6e08\u307f\u3067\u3059\u3002\u7814\u7a76\u5bfe\u8c61\u306e\u907a\u4f1d\u5b50(GOI\uff1agene of interest)\u3092\u54fa\u4e73\u985e\u7d30\u80de\u3067\u767a\u73fe\u3055\u305b\u308b\u305f\u3081\u306b\u3053\u306e\u30d9\u30af\u30bf\u30fc\u3092\u5165\u624b\u3057\u305f\u304c\u3001\u4f7f\u3044\u65b9\u304c\u3044\u307e\u3044\u3061\u308f\u304b\u3089\u306a\u3044\u3068\u3044\u3046\u30b7\u30c1\u30e5\u30a8\u30fc\u30b7\u30e7\u30f3\u3092\u60f3\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/8009079f73326dff3e5b540c260df344.png\" alt=\"\" width=\"470\" height=\"508\" class=\"aligncenter size-full wp-image-18878\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/8009079f73326dff3e5b540c260df344.png 470w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/8009079f73326dff3e5b540c260df344-278x300.png 278w\" sizes=\"auto, (max-width: 470px) 100vw, 470px\" \/><\/p>\n<p><b><u>\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\u6700\u521d\u306b\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u304b\u3089\u8aad\u307f\u53d6\u3089\u306a\u3051\u308c\u3070\u3044\u3051\u306a\u3044\u306e\u306f\u3001\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u3048\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3053\u3053\u3067\u9593\u9055\u3048\u308b\u3068\u3001\u30d7\u30e9\u30b9\u30df\u30c9\u3092\u7528\u3044\u3066\u5927\u8178\u83cc\uff08\u30b3\u30f3\u30d4\u30c6\u30f3\u30c8\u30bb\u30eb\uff09\u3092\u5f62\u8cea\u8ee2\u63db\u3057\u3066\u3082\u30d7\u30ec\u30fc\u30c8\u4e0a\u3067\u5927\u8178\u83cc\u304c\u751f\u3048\u3066\u3053\u306a\u3044\u3068\u3044\u3046\u4e8b\u614b\u306b\u306a\u308a\u304b\u306d\u307e\u305b\u3093\u3002<br \/>\n\u3055\u3066\u3001\uff08\u30a2\uff09\u306e\u9818\u57df\u306b\u201cAmpicillin\u201d\u3001\u3064\u307e\u308a\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u8010\u6027\u907a\u4f1d\u5b50\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304c\u4f7f\u3048\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u307e\u305f\u3001\uff08\u30a6\uff09\u306b\u201cNeomycin\u201d\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u4e0a\u6d41\u306b\u3042\u308b\u306e\u306f\u54fa\u4e73\u985e\u7d30\u80de\u7528\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\uff08SV40 ori\uff09\u306e\u307f\u3067\u5927\u8178\u83cc\u7528\u306e\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u8a18\u8f09\u304c\u306a\u3044\u306e\u3067\u3001\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u30ab\u30ca\u30de\u30a4\u30b7\u30f3\u3092\u4f7f\u3048\u306a\u3044\u53ef\u80fd\u6027\u304c\u9ad8\u3044\u3067\u3059\u3002\u4e0a\u8a18\u306e\u3088\u3046\u306b\u30de\u30c3\u30d7\u4e0a\u304b\u3089\u6297\u751f\u7269\u8cea\u8010\u6027\u907a\u4f1d\u5b50\u3092\u6d17\u3044\u51fa\u3057\u3001\u305d\u308c\u3089\u304c\u5927\u8178\u83cc\u3067\u767a\u73fe\u3059\u308b\u304b\u3069\u3046\u304b\u3092\u5224\u5b9a\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u306a\u304a\u3001\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304c\u4f7f\u3048\u308b\u3053\u3068\u304c\u591a\u3044\u306e\u3067\u3001\u307e\u305a\u306f\u201cAmpicillin\u201d\u3001\u201cAmpR\u201d\u306a\u3069\u3092\u63a2\u3057\u3066\u3044\u305f\u3060\u304f\u306e\u304c\u304a\u52e7\u3081\u3067\u3059\u3002\u306a\u304a\u3001\u30cd\u30aa\u30de\u30a4\u30b7\u30f3\u8010\u6027\u907a\u4f1d\u5b50\u3068\u30ab\u30ca\u30de\u30a4\u30b7\u30f3\u306e\u95a2\u4fc2\u306b\u3064\u3044\u3066\u4ee5\u4e0b\u306b\u8aac\u660e\u3057\u307e\u3057\u305f\u306e\u3067\u3088\u308d\u3057\u3051\u308c\u3070\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<br \/>\n\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/vector-map-guide.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\u30ac\u30a4\u30c9<\/a>\u300d\u306e5\u30da\u30fc\u30b8\u300c\u6297\u751f\u7269\u8cea\u306b\u3064\u3044\u3066\uff5e\u5927\u8178\u83cc\u57f9\u990a\u6642\u306b\u4f7f\u3046\u6297\u751f\u7269\u8cea\u306e\u6c7a\u3081\u65b9\u300d  <\/p>\n<p><b><u>\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b\uff1f\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\uff08\u30a4\uff09\u306b\u30e6\u30cb\u30fc\u30af\u306a\u5236\u9650\u9175\u7d20\uff08\u3053\u306e\u30d9\u30af\u30bf\u30fc\u30921\u30ab\u6240\u3060\u3051\u3067\u5207\u65ad\u3059\u308b\u3082\u306e\uff09\u30b5\u30a4\u30c8\u304c\u4e26\u3093\u3060\u30de\u30eb\u30c1\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\uff08MCS\uff09\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u3053\u3053\u306bGOI\u3092\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001<i>Hind<\/i> III\u3068<i>Xba<\/i> I\u306e2\u30ab\u6240\u3067\u5207\u65ad\u3057\uff08GOI\u914d\u5217\u3092\u5207\u65ad\u3057\u306a\u3044\u9175\u7d20\u3092\u9078\u3073\u307e\u3059\uff09\u3001\u540c\u3058\u9175\u7d20\u30da\u30a2\u3067\u4e21\u7aef\u3092\u5207\u65ad\u3057\u305fGOI\u306ePCR\u7523\u7269\u3092DNA\u30ea\u30ac\u30fc\u30bc\u3067\u30e9\u30a4\u30b2\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u306e\u304c\u30aa\u30fc\u30bd\u30c9\u30c3\u30af\u30b9\u306a\u65b9\u6cd5\u3067\u3059\uff08\u4e0b\u56f3\u53c2\u7167\uff09\u3002\u305d\u306e\u4ed6\u3001Gibson\u306a\u3069\u306e\u30b7\u30fc\u30e0\u30ec\u30b9\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u6cd5\u3067GOI\u3092MCS\u306b\u5c0e\u5165\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/e6ccb241eaa7531073f7ae0b4d39a603.png\" alt=\"\" width=\"1210\" height=\"620\" class=\"aligncenter size-full wp-image-18879\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/e6ccb241eaa7531073f7ae0b4d39a603.png 1210w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/e6ccb241eaa7531073f7ae0b4d39a603-300x154.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/e6ccb241eaa7531073f7ae0b4d39a603-1024x525.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/e6ccb241eaa7531073f7ae0b4d39a603-768x394.png 768w\" sizes=\"auto, (max-width: 1210px) 100vw, 1210px\" \/><\/p>\n<p><b><u>\u30bf\u30b0\u914d\u5217\u3068GOI\u306e\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u305f\u3081\u306b\u306f\u3069\u3046\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\u6b21\u306b\u3001MCS\u306e\u4e0b\u6d41\uff08\u65b9\u5411\u306fCMV\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u77e2\u5370\u306e\u5411\u304d\u304b\u3089\u8003\u3048\u3066\u304f\u3060\u3055\u3044\uff09\u306b\u306fV5 epitope\u30bf\u30b0\u30686xHis\u30bf\u30b0\u306e\u914d\u5217\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30bf\u30b0\u3092GOI\u306eC\u672b\u7aef\u306b\u878d\u5408\u3055\u305b\u305f\u3044\u5834\u5408\u306fGOI\u306eStop\u30b3\u30c9\u30f3\u3092\u9664\u53bb\u3057\u3001\u304b\u3064GOI\u3068\u30bf\u30b0\u914d\u5217\u306e\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001Stop\u30b3\u30c9\u30f3\u3092\u9664\u53bb\u3057\u306a\u3051\u308c\u3070\u878d\u5408\u30bf\u30b0\u306a\u3057\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u767a\u73fe\u3055\u305b\u3089\u308c\u307e\u3059\u3002<br \/>\n\u306a\u304a\u3001\u4e21\u8005\u306e\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u305f\u3081\u306b\u306f\u30de\u30c3\u30d7\u306e\u60c5\u5831\u3060\u3051\u3067\u306f\u4e0d\u5341\u5206\u3067\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u5468\u8fba\u306e\u5869\u57fa\u914d\u5217\u60c5\u5831\u304c\u5fc5\u9808\u3067\u3059\u3002<br \/>\n\u307e\u305a\u3001\u5f53\u793e\u306e\u30d9\u30af\u30bf\u30fc\u306e\u591a\u304f\u306b\u3064\u3044\u3066\u306f\u3001Web\u30de\u30cb\u30e5\u30a2\u30eb\u306a\u3069\u3067\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u56f3\u3092\u3054\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u201cPolylinker\u201d\u3068\u8a18\u8f09\u3055\u308c\u305f\u8cc7\u6599\uff08\u30d5\u30a1\u30a4\u30eb\uff09\u304c\u3042\u308c\u3070\u305d\u3061\u3089\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002\u3082\u3057\u306a\u3051\u308c\u3070\u540c\u3058\u3088\u3046\u306a\u56f3\u3092\u4f5c\u3089\u308c\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u5869\u57fa\u914d\u5217\u304c\u8aad\u307f\u67a0\u3054\u3068\u306b\u533a\u5207\u3089\u308c\u3066\u3044\u308b\u3060\u3051\u3067\u3082\u6709\u7528\u3067\u3059\u3002\u304a\u624b\u6570\u3067\u306a\u3051\u308c\u3070\u305d\u306e\u4e0b\u306b\u5bfe\u5fdc\u3059\u308b\u30a2\u30df\u30ce\u9178\u540d\u3092\u8a18\u8f09\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/f021380614da264f162072aa473c7620.png\" alt=\"\" width=\"839\" height=\"345\" class=\"aligncenter size-full wp-image-18880\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/f021380614da264f162072aa473c7620.png 839w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/f021380614da264f162072aa473c7620-300x123.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/f021380614da264f162072aa473c7620-768x316.png 768w\" sizes=\"auto, (max-width: 839px) 100vw, 839px\" \/><\/p>\n<p>\u4e0a\u8a18\u306f\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306eMCS\u5468\u8fba\u306e\u5869\u57fa\u914d\u5217\u3092\u8a18\u8f09\u3057\u305f\u56f3\u3067\u3059\u3002\u4e0b\u7dda\uff08\u8d64\uff09\u306f<i>Hind<\/i> III\u30fb<i>Xba<\/i> I\u306e\u8a8d\u8b58\u30fb\u5207\u65ad\u914d\u5217\uff086\u5869\u57fa\uff09\u3067\u3059\u3002\u5869\u57fa\u914d\u5217\u306f\u30bf\u30b0\u914d\u5217\uff08V5 epitope\u30fbPolyhistidine tag\uff09\u306b\u5408\u308f\u305b\u305f\u8aad\u307f\u67a0\uff083\u5869\u57fa\uff09\u3054\u3068\u306b\u533a\u5207\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u5869\u57fa\u914d\u5217\u306e\u4e0b\u306b\u5404\u30b3\u30c9\u30f3\u304c\u6307\u5b9a\u3059\u308b\u30a2\u30df\u30ce\u9178\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u8aad\u307f\u67a0\u3092\u58ca\u3055\u306a\u3044\u3088\u3046\u306b\uff08\u305a\u308c\u306a\u3044\u3088\u3046\u306b\uff09\u4f7f\u7528\u3059\u308b\u5236\u9650\u9175\u7d20\u30b5\u30a4\u30c8\u306e\u524d\u306bGOI\u914d\u5217\u3092\u633f\u5165\u3059\u308c\u3070\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002<br \/>\n\u4f8b\u3048\u3070<i>Xba<\/i> I\u30b5\u30a4\u30c8\uff08TCTAGA\uff09\u3092\u5229\u7528\u3059\u308b\u5834\u5408\u3067\u3059\u304c\u3001Stop\u30b3\u30c9\u30f3\u3092\u9664\u53bb\u3057\u305fGOI\u914d\u5217\u3068\u30ea\u30f3\u30ab\u30fc\u306a\u3057\u3067\u76f4\u7d50\u3059\u308c\u3070\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u8aad\u307f\u67a0\u3054\u3068\u306b\u533a\u5207\u3063\u3066\u66f8\u3044\u3066\u307f\u305f\u3089\u308f\u304b\u308a\u3084\u3059\u3044\u3067\u3059\u3002GOI\u306e\u8aad\u307f\u67a0\u3068V5 epitope\u30bf\u30b0\u306e\u8aad\u307f\u67a0\u304c\u305a\u308c\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u4ee5\u4e0b\u4f8b\u306eGOI\u306e3\u2019\u672b\u7aef\u306e\u5869\u57fa\u914d\u5217\u3068\u8aad\u307f\u67a0\u306fGAC GAG CTG TAT AAG TAG\u3067\u3059\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/4740bdd0be7c4d9f417c02e7e7e017d2.png\" alt=\"\" width=\"982\" height=\"129\" class=\"aligncenter size-full wp-image-18881\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/4740bdd0be7c4d9f417c02e7e7e017d2.png 982w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/4740bdd0be7c4d9f417c02e7e7e017d2-300x39.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/4740bdd0be7c4d9f417c02e7e7e017d2-768x101.png 768w\" sizes=\"auto, (max-width: 982px) 100vw, 982px\" \/><\/p>\n<p>\u3061\u306a\u307f\u306b\u3001\u3082\u3057Xba I\u306e\u8aad\u307f\u67a0\u304cT\u3000CTA\u3000GA\u306e\u5834\u5408\u306f\u3001GOI\u914d\u5217\u306e3\u2019\u672b\u7aef\u306b\u4f55\u304b\u9069\u5f53\u306a2\u5869\u57fa\u3092\u633f\u5165\u3057\u3066\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/b0c76a912dbbce1994e9e4d648bb2301.png\" alt=\"\" width=\"995\" height=\"165\" class=\"aligncenter size-full wp-image-18882\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/b0c76a912dbbce1994e9e4d648bb2301.png 995w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/b0c76a912dbbce1994e9e4d648bb2301-300x50.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/b0c76a912dbbce1994e9e4d648bb2301-768x127.png 768w\" sizes=\"auto, (max-width: 995px) 100vw, 995px\" \/><\/p>\n<p>\u306a\u304a\u4e0a\u8a18\u4f8b\u3067\u306f<i>Xba<\/i> I\u3068V5 epitope\u30bf\u30b0\u914d\u5217\u306e\u9593\u306e\u5869\u57fa\u30922\u5869\u57fa\u524a\u9664\u3057\u3066\u8aad\u307f\u67a0\u3092\u3042\u3048\u3066\u305a\u3089\u3057\u305f\u306e\u3067\u5bfe\u5fdc\u3059\u308b\u30a2\u30df\u30ce\u9178\u3082\u5909\u308f\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<p><b><u>\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u5f8c\u306e\u914d\u5217\u78ba\u8a8d\u306f\u3069\u3046\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u5f8c\u306b\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u914d\u5217\u3068\u305d\u306e\u5468\u8fba\u306b\u3064\u3044\u3066DNA\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u914d\u5217\u78ba\u8a8d\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002PCR\u30a8\u30e9\u30fc\u304c\u8d77\u3053\u3063\u3066\u3044\u306a\u3044\u304b\u3001\u3064\u306a\u304e\u76ee\u304c\u6b63\u3057\u3044\u304b\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u3067\u3059\u3002\u305d\u306e\u969b\u306b\u4f7f\u7528\u3067\u304d\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u914d\u5217\u304cMCS\u5468\u8fba\u306b\u6e96\u5099\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u307e\u305a\u306f\u305d\u308c\u3089\u306e\u4f7f\u7528\u3092\u3054\u691c\u8a0e\u3044\u305f\u3060\u304f\u306e\u304c\u304a\u52e7\u3081\u3067\u3059\u3002\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u306fMCS\u306e\u4e0a\u6d41\u306bT7 promoter\/priming site\u3001\u4e0b\u6d41\u306bBGH reveres priming site\u304c\u6e96\u5099\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u4ed6\u3001\u56f3\u306b\u306f\u8a18\u8f09\u304c\u3042\u308a\u307e\u305b\u3093\u304c\u3001V5 epitope\u30bf\u30b0\u914d\u5217\u4e0a\u306b\u3082\u78ba\u8a8d\u6e08\u307f\u306e\u30d7\u30e9\u30a4\u30de\u30fc\u914d\u5217\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><b><u>\u5b89\u5b9a\u767a\u73fe\u682a\u3092\u9078\u5225\u3059\u308b\u969b\u306f\u3069\u3046\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\u5b89\u5b9a\u767a\u73fe\u682a\u3092\u4f5c\u6210\u3059\u308b\u969b\u306f\u3001\u7d30\u80de\u306e\u9078\u5225\u306b\u4f7f\u7528\u53ef\u80fd\u306a\u6297\u751f\u7269\u8cea\u3092\u30de\u30c3\u30d7\u304b\u3089\u8aad\u307f\u53d6\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u306f\uff08\u30a6\uff09\u306b\u201cNeomycin\u201d\u3068\u3042\u308b\u306e\u3067\u3001\u30cd\u30aa\u30de\u30a4\u30b7\u30f3\u8010\u6027\u907a\u4f1d\u5b50\u3067\u7121\u6bd2\u5316\u3067\u304d\u308bG418\u7cfb\u6297\u751f\u7269\u8cea\uff08Geneticin\u306a\u3069\uff09\u304c\u4f7f\u3048\u308b\u53ef\u80fd\u6027\u304c\u9ad8\u305d\u3046\u3067\u3059\u3002\u5ff5\u306e\u305f\u3081\u4e0a\u6d41\u306b\u54fa\u4e73\u985e\u7d30\u80de\u3067\u6a5f\u80fd\u3059\u308b\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\uff08\u308f\u304b\u308a\u306b\u304f\u3044\u540d\u524d\u3067\u3059\u304cSV40 origin\uff09\u3001\u304a\u3088\u3073\u30dd\u30eaA\u4ed8\u52a0\u30b7\u30b0\u30ca\u30eb\uff08SV40 pA\uff09\u304c\u3042\u308b\u3053\u3068\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002\u306a\u304a\u3001\uff08\u30a2\uff09\u306b\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u8010\u6027\u907a\u4f1d\u5b50\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u4ee5\u4e0b\u306e\u7406\u7531\u3067\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u306f\u5b89\u5b9a\u682a\u306e\u9078\u5225\u306b\u306f\u4f7f\u3048\u307e\u305b\u3093\u3002<\/p>\n<ul>\n<li>\u54fa\u4e73\u985e\u7d30\u80de\u3067\u306f\u767a\u73fe\u3057\u306a\u3044\u53ef\u80fd\u6027\u304c\u9ad8\u3044\uff08\u54fa\u4e73\u985e\u7d30\u80de\u3067\u6a5f\u80fd\u3059\u308b\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304c\u306a\u3055\u305d\u3046\uff09<\/li>\n<li>\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u306f\u54fa\u4e73\u985e\u7d30\u80de\u306b\u306f\u52b9\u304b\u306a\u3044<\/li>\n<\/ul>\n<h2>\u4f8b2\uff1a\u4e00\u822c\u7684\u306a\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u30d9\u30af\u30bf\u30fc\uff08\u76ee\u7684\u907a\u4f1d\u5b50\u633f\u5165\u6e08\u307f\uff09<\/h2>\n<p>\u4f8b1\u3068\u540c\u3058\u304f\u54fa\u4e73\u985e\u7d30\u80de\u3092\u4f7f\u3063\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3092\u884c\u3044\u305f\u3044\u30b1\u30fc\u30b9\u3067\u3059\u304c\u3001\u4eca\u56de\u306f<i>TFS1<\/i>\u3068\u3044\u3046\u907a\u4f1d\u5b50\u304c\u3059\u3067\u306b\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3055\u308c\u3066\u3044\u308b\u30d9\u30af\u30bf\u30fc\u306e\u4f8b\u3067\u3059\u3002\u77e5\u308a\u5408\u3044\u306e\u5148\u751f\u304b\u3089\u300c<i>TFS1<\/i>\u907a\u4f1d\u5b50\u3042\u3052\u308b\u3088\u300d\u3068\u8b72\u308a\u53d7\u3051\u305f\u304c\u3069\u3046\u6271\u3063\u305f\u3089\u3044\u3044\u304b\u308f\u304b\u3089\u306a\u3044\u3001\u304b\u3064\u5c11\u3057\u3057\u304b\u3082\u3089\u3048\u306a\u304b\u3063\u305f\u306e\u3067\u5897\u3084\u3055\u306a\u3044\u3068\u3044\u3051\u306a\u3044\u3001\u3068\u3044\u3046\u30b7\u30c1\u30e5\u30a8\u30fc\u30b7\u30e7\u30f3\u3092\u60f3\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30b1\u30fc\u30b9\u3082\u7d50\u69cb\u3042\u308b\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u30d7\u30e9\u30b9\u30df\u30c9\u6eb6\u6db2\u3068\u4e00\u7dd2\u306b\u5c4a\u3044\u305f\u306e\u304c\u4e0b\u8a18\u30de\u30c3\u30d7\u3067\u3059\u3002\u53d7\u3051\u53d6\u308a\u5f8c\u3001\u65e9\u901f\uff08\u30a2\uff09\u3001\uff08\u30a4\uff09\u3001\uff08\u30a6\uff09\u306b\u5206\u985e\u3057\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/8ebf2931546608abe801d064518445e7.png\" alt=\"\" width=\"462\" height=\"514\" class=\"aligncenter size-full wp-image-18884\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/8ebf2931546608abe801d064518445e7.png 462w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/8ebf2931546608abe801d064518445e7-270x300.png 270w\" sizes=\"auto, (max-width: 462px) 100vw, 462px\" \/><\/p>\n<p><b><u>\u5927\u8178\u83cc\u306e\u57f9\u990a\u6642\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\uff08\u30a2\uff09\u306b\u201cAmpicillin\u201d\u3068\u3044\u3046\u6587\u5b57\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304c\u4f7f\u3048\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u307e\u305f\u3001\uff08\u30a6\uff09\u306e\u201cZeocin\u201d\u306e\u4e0a\u6d41\u306bEM7\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304c\u3042\u308b\u306e\u3067ZeocinTM\u3082\u4f7f\u3048\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u7279\u306b\u7406\u7531\u304c\u306a\u3051\u308c\u3070\u5b89\u4fa1\u306a\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u3092\u4f7f\u3046\u306e\u304c\u304a\u52e7\u3081\u3067\u3059\u3002\u306a\u304a\u3001\u30ab\u30eb\u30d9\u30cb\u30b7\u30ea\u30f3\u3092\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u306e\u4ee3\u308f\u308a\u306b\u4f7f\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30d7\u30ec\u30fc\u30c8\u4e0a\u3067\u306e\u5b89\u5b9a\u6027\u304c\u9ad8\u304f\u3001\u30b5\u30c6\u30e9\u30a4\u30c8\u30b3\u30ed\u30cb\u30fc\u304c\u51fa\u306b\u304f\u3044\u306e\u3067\u4f7f\u3044\u3084\u3059\u3044\u3067\u3059\u3002<br \/>\n\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304c\u4f7f\u3048\u308b\u3053\u3068\u304c\u5206\u304b\u3063\u305f\u306e\u3067\u3001DH5\u03b1\u306a\u3069\u306e\u5927\u8178\u83cc\uff08\u30b3\u30f3\u30d4\u30c6\u30f3\u30c8\u30bb\u30eb\uff09\u306b\u5c0e\u5165\u3057\u3001\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u8010\u6027\u3092\u6301\u3064\u30b3\u30ed\u30cb\u30fc\u3092\u9078\u5225\u3057\u305f\u3089\u3001\u30d4\u30c3\u30af\u3057\u305f\u30b3\u30ed\u30cb\u30fc\u306e\u57f9\u990a\u6db2\u304b\u3089\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u30b0\u30ec\u30fc\u30c9\u306e\u30ad\u30c3\u30c8\u3092\u4f7f\u3063\u3066\u30d7\u30e9\u30b9\u30df\u30c9\u8abf\u88fd\u3068\u3044\u3046\u6d41\u308c\u306b\u306a\u308b\u306f\u305a\u3067\u3059\u3002\u306a\u304a\u3001\u3082\u3046\u5c11\u3057\u30de\u30c3\u30d7\u3092\u8abf\u3079\u3066\u304b\u3089\u5148\u306b\u9032\u307f\u305f\u3044\u65b9\u306f\u4ee5\u4e0b\u3082\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><b><u>\u54fa\u4e73\u985e\u7d30\u80de\u306b\u5165\u308c\u305f\u3089\u767a\u73fe\u3059\u308b\u306e\u304b\uff1f<\/u><\/b><br \/>\n  \u5ff5\u306e\u305f\u3081\u672c\u5f53\u306b\u54fa\u4e73\u985e\u7d30\u80de\u3067\u767a\u73fe\u3059\u308b\u306e\u304b\u78ba\u8a8d\u3057\u305f\u3044\u3053\u3068\u3082\u3042\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u805e\u304d\u9593\u9055\u3044\u3068\u3044\u3046\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3057\u3001\u81ea\u5206\u306e\u52c9\u5f37\u306e\u305f\u3081\u3067\u3082\u3042\u308a\u307e\u3059\u3002\u305d\u3093\u306a\u6642\u306f\u307e\u305aTFS1\u907a\u4f1d\u5b50\u306e\u4e0a\u6d41\u306b\u54fa\u4e73\u985e\u7d30\u80de\u7528\u306e\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304c\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002TFS1\u306e\u77e2\u5370\u306e\u5411\u304d\u304b\u3089\u4e0a\u6d41\u30fb\u4e0b\u6d41\u3092\u5224\u65ad\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3069\u3046\u3067\u3057\u3087\u3046\u304b\uff1fPEF-1\u03b1 = EF1\u03b1\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304c\u898b\u3064\u304b\u3063\u305f\u3067\u3057\u3087\u3046\u304b\u3002\u5ff5\u306e\u305f\u3081\u7b2c2\u56de\u306e\u30a8\u30ec\u30e1\u30f3\u30c8\u30ea\u30b9\u30c8\u3067\u3001EF1\u03b1\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304c\u54fa\u4e73\u985e\u7d30\u80de\u3067\u6a5f\u80fd\u3059\u308b\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u6700\u3082\u4e00\u822c\u7684\u306aCMV\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3088\u308a\u3082\u8ee2\u5199\u6d3b\u6027\u306f\u5f31\u3081\u306e\u3088\u3046\u3067\u3059\u304c\u3001\u5341\u5206\u4f7f\u3048\u305d\u3046\u3067\u3059\u3002\u3055\u3089\u306b\u3001<i>TFS1<\/i>\u907a\u4f1d\u5b50\u306e\u4e0b\u6d41\u306b\u306f\u30dd\u30eaA\u4ed8\u52a0\u30b7\u30b0\u30ca\u30eb\uff08BGH pA\uff09\u304c\u3042\u308b\u306e\u3067\u3055\u3089\u306b\u5b89\u5fc3\u3067\u304d\u305d\u3046\u3067\u3059\u3002\u306a\u304a\u3001\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7cfb\u306e\u5834\u5408\u3001\u7ffb\u8a33\u958b\u59cb\u30b3\u30c9\u30f3\uff08ATG\uff09\u306e\u524d\u30fb\u5468\u8fba\u306b\u30b3\u30b6\u30c3\u30af\uff08Kozak\uff09\u30b3\u30f3\u30bb\u30f3\u30b5\u30b9\u914d\u5217\u3092\u4ed8\u52a0\u3059\u308b\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u304c\u3001\u901a\u5e38\u30de\u30c3\u30d7\u306b\u306f\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u4ed8\u3051\u306a\u3044\u3068\u767a\u73fe\u3057\u306a\u3044\u3068\u3044\u3046\u3053\u3068\u306f\u306a\u3044\u306f\u305a\u3067\u3059\u304c\u3001\u6c17\u306b\u306a\u308b\u5834\u5408\u306f\u5869\u57fa\u914d\u5217\u60c5\u5831\u3092\u3082\u3089\u3063\u3066\u78ba\u8a8d\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p><b><u>C\u672b\u7aef\u30bf\u30b0\u914d\u5217\u306f\u4ed8\u304f\u306e\u304b\uff1f<\/u><\/b><br \/>\n\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u3001MCS\u306e\u4e0b\u6d41\u306bmyc epitope\u30bf\u30b0\u30fb6 x His\u30bf\u30b0\u914d\u5217\u304c\u3042\u308a\u307e\u3059\u3002<i>TFS1<\/i>\u907a\u4f1d\u5b50\u3068\u30bf\u30b0\u914d\u5217\u306e\u8aad\u307f\u67a0\u304c\u5408\u3063\u3066\u3044\u3066\u3001\u304b\u3064<i>TFS1<\/i>\u306eStop\u30b3\u30c9\u30f3\u304c\u9664\u53bb\u3055\u308c\u3066\u3044\u305f\u3089\u3001\u4f8b\u3048\u3070myc\u6297\u4f53\u3092\u4f7f\u3063\u305f\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3001\u514d\u75ab\u86cd\u5149\u67d3\u8272\u3001\u3042\u308b\u3044\u306f6 x His\u30bf\u30b0\u914d\u5217\u3068\u7279\u7570\u7684\u306b\u7d50\u5408\u3059\u308bNi-NTA\u30ab\u30e9\u30e0\u3092\u4f7f\u3063\u305f\u767a\u73fe\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7cbe\u88fd\u3092\u884c\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<br \/>\n\u6b8b\u5ff5\u306a\u304c\u3089\u30de\u30c3\u30d7\u304b\u3089\u306f\u8aad\u307f\u67a0\u304a\u3088\u3073Stop\u30b3\u30c9\u30f3\u306e\u6709\u7121\u3092\u78ba\u8a8d\u3067\u304d\u307e\u305b\u3093\u306e\u3067\u3001\u5148\u751f\u306b\u805e\u3044\u3066\u307f\u308b\u304b\u3001<i>TFS1<\/i>\u907a\u4f1d\u5b50\u5468\u8fba\u306e\u914d\u5217\u3092\u3082\u3089\u3046\u3057\u304b\u3042\u308a\u307e\u305b\u3093\u3002\u914d\u5217\u304c\u624b\u306b\u5165\u308c\u3070\u3001<i>TFS1<\/i>\u907a\u4f1d\u5b50\u3068\u30bf\u30b0\u914d\u5217\u306e\u8aad\u307f\u67a0\u304c\u5408\u3063\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u3001Stop\u30b3\u30c9\u30f3\u304c\u524a\u9664\u3055\u308c\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u3044\u3044\u6297<i>TFS1<\/i>\u6297\u4f53\u304c\u624b\u5143\u306b\u3042\u308b\u5834\u5408\u3067\u3082\u3001\u4e88\u6e2c\u5206\u5b50\u91cf\u3092\u7b97\u51fa\u3059\u308b\u305f\u3081\u306b\u30bf\u30b0\u304c\u4ed8\u304f\u304b\u3069\u3046\u304b\u306e\u78ba\u8a8d\u306f\u5fc5\u8981\u3067\u3059\u3002<\/p>\n<p><b><u>\u5b89\u5b9a\u767a\u73fe\u682a\u3092\u9078\u5225\u3059\u308b\u969b\u306f\u3069\u3046\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\uff08\u30a6\uff09\u306b\u201cZeocin\u201d\u304c\u3042\u308b\u306e\u3067\u5b89\u5b9a\u767a\u73fe\u682a\u306e\u9078\u5225\u306b\u306fZeocin\u304c\u4f7f\u3048\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u5b89\u5b9a\u767a\u73fe\u682a\u306e\u4f5c\u6210\u3092\u8a66\u307f\u3089\u308c\u308b\u5834\u5408\u306f\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u5f8cZeocin\u3092\u7528\u3044\u3066\u8010\u6027\u7d30\u80de\u306e\u9078\u5225\u3092\u884c\u3048\u307e\u3059\u3002<\/p>\n<p><b><u><i>TFS1<\/i>\u907a\u4f1d\u5b50\u3092\u4ed6\u306e\u30d9\u30af\u30bf\u30fc\u306b\u79fb\u3057\u305f\u3044\u5834\u5408\u306f\u3069\u3046\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/u><\/b><br \/>\n\u54fa\u4e73\u985e\u7d30\u80de\u4ee5\u5916\u3067\u3082\u767a\u73fe\u3055\u305b\u305f\u3044\u5834\u5408\u306a\u3069\u3001<i>TFS1<\/i>\u907a\u4f1d\u5b50\u3092\u4ed6\u306e\u30d9\u30af\u30bf\u30fc\u306b\u79fb\u3059\u5fc5\u8981\u304c\u51fa\u3066\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u30de\u30c3\u30d7\u3092\u8abf\u3079\u305f\u3068\u3053\u308d\u5b9f\u306f\u54fa\u4e73\u985e\u7d30\u80de\u3067\u306f\u767a\u73fe\u3057\u305d\u3046\u306b\u306a\u3044\u3053\u3068\u304c\u5206\u304b\u3063\u305f\u5834\u5408\u3082\u5fc5\u8981\u306a\u64cd\u4f5c\u3067\u3059\u3002\u4e00\u822c\u7684\u306b\u306f\u4ee5\u4e0b\u306e\u65b9\u6cd5\u3067\u5225\u306e\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306b\u79fb\u3059\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<br \/>\n\u65b9\u6cd51<br \/>\n<i>TFS1<\/i>\u907a\u4f1d\u5b50\u306e\u4e21\u7aef\u306b\u3042\u308b\u5236\u9650\u9175\u7d20\u30b5\u30a4\u30c8\u3067\u5207\u65ad<br \/>\n\u2192\u3067\u304d\u308c\u3070\u540c\u3058\u5236\u9650\u9175\u7d20\u3067\u5207\u65ad\u3057\u305f\u4e57\u305b\u63db\u3048\u305f\u3044\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306b\u30e9\u30a4\u30b2\u30fc\u30b7\u30e7\u30f3<br \/>\n\u65b9\u6cd52<br \/>\n<i>TFS1<\/i>\u907a\u4f1d\u5b50\u3092PCR\u3067\u5897\u5e45\uff08\u4f7f\u7528\u3059\u308b\u30d7\u30e9\u30a4\u30de\u30fc\u30da\u30a2\u306e\u4e21\u7aef\u306b\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u306b\u4f7f\u7528\u3059\u308b\u5236\u9650\u9175\u7d20\u30b5\u30a4\u30c8\u3092\u4ed8\u52a0\uff09<br \/>\n\u2192\u5236\u9650\u9175\u7d20\u5207\u65ad\u2192\u540c\u3058\u5236\u9650\u9175\u7d20\u3067\u5207\u65ad\u3057\u305f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306b\u30e9\u30a4\u30b2\u30fc\u30b7\u30e7\u30f3<br \/>\n\u65b9\u6cd53<br \/>\n<i>TFS1<\/i>\u907a\u4f1d\u5b50\u306e\u5408\u6210\u304b\u3089\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u3078\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u307e\u3067\u3092\u5f53\u793e\u306e\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u3067\u4f9d\u983c\u3059\u308b<\/p>\n<p>\u3044\u305a\u308c\u304b\u3084\u308a\u3084\u3059\u305d\u3046\u306a\u65b9\u6cd5\u3092\u9078\u3093\u3067\u304f\u3060\u3055\u3044\u3002\u306a\u304a\u3001\u4f7f\u3048\u308b\u5236\u9650\u9175\u7d20\u30b5\u30a4\u30c8\u304c\u5b58\u5728\u3057\u306a\u3044\u30b1\u30fc\u30b9\u3082\u591a\u3044\u305f\u3081\u3001\u65b9\u6cd51\u306f\u56f0\u96e3\u306a\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u3002\u6700\u8fd1\u306ePCR\u7528\u9175\u7d20\u306f\u30a8\u30e9\u30fc\u7387\u304c\u304b\u306a\u308a\u4e0b\u304c\u308a\u6210\u529f\u7387\u3082\u4e0a\u304c\u3063\u305f\u306e\u3067\u65b9\u6cd52\u3001\u3042\u308b\u3044\u306f\u4ee5\u524d\u3088\u308a\u304b\u306a\u308a\u5b89\u304f\u306a\u308a\u6ce8\u6587\u3057\u3084\u3059\u304f\u306a\u3063\u305f\u306e\u3067\u65b9\u6cd53\u304c\u9078\u3070\u308c\u308b\u3053\u3068\u304c\u591a\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n<h2>\u307e\u3068\u3081<\/h2>\n<p>\u5b9f\u4f8b\u96c61\u3067\u306f\u54fa\u4e73\u985e\u7d30\u80de\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc\u3092\u4f8b\u306b\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u304a\u6301\u3061\u306e\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u5f79\u306b\u7acb\u3061\u305d\u3046\u3067\u3057\u3087\u3046\u304b\uff1f<br \/>\n\u6b21\u56de\u7b2c4\u56de\u3067\u306f\u4ed6\u306e\u767a\u73fe\u7cfb\u7528\u306e\u30d9\u30af\u30bf\u30fc\u304a\u3088\u3073\u3001\u5c11\u3057\u5909\u308f\u3063\u305f\u30d9\u30af\u30bf\u30fc\u306e\u4f8b\u3092\u3054\u7d39\u4ecb\u3059\u308b\u4e88\u5b9a\u3067\u3059\u3002\u3088\u308d\u3057\u3051\u308c\u3070\u305d\u3061\u3089\u3082\u4f75\u305b\u3066\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u5b9f\u969b\u304a\u6301\u3061\u306e\u30d7\u30e9\u30b9\u30df\u30c9\u30d9\u30af\u30bf\u30fc\u306e\u89e3\u8aad\u30b5\u30dd\u30fc\u30c8\u3044\u305f\u3057\u307e\u3059\uff01<br \/>\n\u3082\u3061\u308d\u3093\u5f53\u793e\u306e\u3082\u306e\u3067\u306a\u304f\u3066\u3082\u69cb\u3044\u307e\u305b\u3093\u3002<br \/>\n\u30de\u30c3\u30d7\u3092\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u5b9b\u3066\u306b\u304a\u9001\u308a\u304f\u3060\u3055\u3044\u3002<br \/>\n<a href=\"mailto:jptech@thermofisher.com\">jptech@thermofisher.com<\/a><br \/>\n\u3042\u308b\u3044\u306f\u3001\u4ee5\u4e0b\u306e\u30d5\u30a9\u30fc\u30e0\u304b\u3089\u3054\u4f9d\u983c\u304f\u3060\u3055\u3044\u3002<\/p>\n<p>\u672c\u30d6\u30ed\u30b0\u306b\u95a2\u9023\u3059\u308b\u30ea\u30f3\u30af<br \/>\n\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b<br \/>\n\u7b2c1\u56de \u30d7\u30e9\u30b9\u30df\u30c9\u30d9\u30af\u30bf\u30fc\u306e\u69cb\u9020\u3068\u30de\u30c3\u30d7\u304b\u3089\u5206\u304b\u308b\u3053\u3068<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-bid-ts-1\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-bid-ts-1\/<\/a><\/p>\n<p>\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b<br \/>\n\u7b2c2\u56de \u30d7\u30e9\u30b9\u30df\u30c9\u30d9\u30af\u30bf\u30fc\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u30ea\u30b9\u30c8<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-2-bid-ts-mbr-24076\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-2-bid-ts-mbr-24076\/<\/a>   <\/p>\n<p>\u30c6\u30af\u30cb\u30ab\u30eb\u30bb\u30df\u30ca\u30fc\uff08\u7121\u6599\uff09<br \/>\n\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/vector-maps.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/vector-maps.html<\/a><\/p>\n<p>\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\uff08\u6709\u511f\uff09<br \/>\n\u521d\u3081\u3066\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0 \u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/cloning.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\">https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/cloning.html<\/a><\/p>\n<h3>\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\u30ac\u30a4\u30c9 \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h3>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/vector-map-guide.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<h3>Protein Expression\u30cf\u30f3\u30c9\u30d6\u30c3\u30af \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h3>\n<p>\u30bf\u30f3\u30d1\u30af\u767a\u73fe\u306e\u5b9f\u9a13\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u65b9\u3084\u3001\u8a73\u7d30\u60c5\u5831\u3092\u78ba\u8a8d\u3057\u305f\u3044\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/protein-expression-handbook-download.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_3_bid_ts_mbr_25003_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<br \/>\nZeocin is a trademark of InvivoGen.<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3055\u3066\u3001\u7b2c3\u56de\u3067\u3059\u3002\u6700\u7d42\u56de\u306e\u4e88\u5b9a\u3067\u3057\u305f\u304c\u3001\u5c11\u3057\u9577\u304f\u306a\u3063\u305f\u306e\u30672\u56de\u306b\u5206\u3051\u308b\u3053\u3068\u306b\u3044\u305f\u3057\u307e\u3057\u305f\u3002\u6b21\u56de\u306e\u5b9f\u4f8b\u96c62\u304c\u6700\u7d42\u56de\u3068\u306a\u308b\u306f\u305a\u3067\u3059\u3002\u3088\u308d\u3057\u3051\u308c\u3070\u3082\u3046\u5c11\u3057\u304a\u4ed8\u304d\u5408\u3044\u304f\u3060\u3055\u3044\u3002 2\u56de\u306b\u308f\u305f\u308a\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092<\/p>\n","protected":false},"author":975,"featured_media":18874,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[14,168],"division":[],"class_list":["post-18873","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-cloning","tag-protein-expression","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61\" \/>\n<meta property=\"og:description\" content=\"\u3055\u3066\u3001\u7b2c3\u56de\u3067\u3059\u3002\u6700\u7d42\u56de\u306e\u4e88\u5b9a\u3067\u3057\u305f\u304c\u3001\u5c11\u3057\u9577\u304f\u306a\u3063\u305f\u306e\u30672\u56de\u306b\u5206\u3051\u308b\u3053\u3068\u306b\u3044\u305f\u3057\u307e\u3057\u305f\u3002\u6b21\u56de\u306e\u5b9f\u4f8b\u96c62\u304c\u6700\u7d42\u56de\u3068\u306a\u308b\u306f\u305a\u3067\u3059\u3002\u3088\u308d\u3057\u3051\u308c\u3070\u3082\u3046\u5c11\u3057\u304a\u4ed8\u304d\u5408\u3044\u304f\u3060\u3055\u3044\u3002 2\u56de\u306b\u308f\u305f\u308a\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-01-21T05:52:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-01-21T06:58:51+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png\" \/>\n\t<meta property=\"og:image:width\" content=\"549\" \/>\n\t<meta property=\"og:image:height\" content=\"569\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"21\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61\",\"datePublished\":\"2025-01-21T05:52:41+00:00\",\"dateModified\":\"2025-01-21T06:58:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/\"},\"wordCount\":201,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/01\\\/7d646e9c0381dce3159cba0ead88fb90.png\",\"keywords\":[\"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\",\"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/\",\"name\":\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/01\\\/7d646e9c0381dce3159cba0ead88fb90.png\",\"datePublished\":\"2025-01-21T05:52:41+00:00\",\"dateModified\":\"2025-01-21T06:58:51+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/01\\\/7d646e9c0381dce3159cba0ead88fb90.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/01\\\/7d646e9c0381dce3159cba0ead88fb90.png\",\"width\":549,\"height\":569},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-3-bid-ts-mbr-25003\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61","og_description":"\u3055\u3066\u3001\u7b2c3\u56de\u3067\u3059\u3002\u6700\u7d42\u56de\u306e\u4e88\u5b9a\u3067\u3057\u305f\u304c\u3001\u5c11\u3057\u9577\u304f\u306a\u3063\u305f\u306e\u30672\u56de\u306b\u5206\u3051\u308b\u3053\u3068\u306b\u3044\u305f\u3057\u307e\u3057\u305f\u3002\u6b21\u56de\u306e\u5b9f\u4f8b\u96c62\u304c\u6700\u7d42\u56de\u3068\u306a\u308b\u306f\u305a\u3067\u3059\u3002\u3088\u308d\u3057\u3051\u308c\u3070\u3082\u3046\u5c11\u3057\u304a\u4ed8\u304d\u5408\u3044\u304f\u3060\u3055\u3044\u3002 2\u56de\u306b\u308f\u305f\u308a\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-01-21T05:52:41+00:00","article_modified_time":"2025-01-21T06:58:51+00:00","og_image":[{"width":549,"height":569,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"21\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61","datePublished":"2025-01-21T05:52:41+00:00","dateModified":"2025-01-21T06:58:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/"},"wordCount":201,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png","keywords":["\u30af\u30ed\u30fc\u30cb\u30f3\u30b0","\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/","name":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png","datePublished":"2025-01-21T05:52:41+00:00","dateModified":"2025-01-21T06:58:51+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png","width":549,"height":569},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b \u7b2c3\u56de \u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c61"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":14,"label":"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0"},{"value":168,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png",549,569,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":14,"name":"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0","slug":"cloning","term_group":0,"term_taxonomy_id":14,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":168,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe","slug":"protein-expression","term_group":0,"term_taxonomy_id":168,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/01\/7d646e9c0381dce3159cba0ead88fb90.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18873","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=18873"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/18873\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/18874"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=18873"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=18873"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=18873"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=18873"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}