{"id":19837,"date":"2025-03-05T17:59:56","date_gmt":"2025-03-05T08:59:56","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=19837"},"modified":"2025-11-12T17:28:07","modified_gmt":"2025-11-12T08:28:07","slug":"twin-screw-extrusion-extruder-cad-25011","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/","title":{"rendered":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3001\u30b4\u30e0\u3001\u98df\u54c1\u3001\u98fc\u6599\u3001\u533b\u85ac\u54c1\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5206\u91ce\u3067\u306e\u6750\u6599\u6539\u8cea\u3001\u52a0\u5de5\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u62bc\u51fa\u6210\u5f62\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u521d\u56de\u306f\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u4ed5\u7d44\u307f\u3068\u7a2e\u985e\u3001\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\"><strong>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><b>\u306a\u3093\u3068\u306a\u304f\u4f7f\u3063\u3066\u3044\u308b\u3051\u308c\u3069\u3001\u3082\u3063\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u3053\u3068\u3092\u7406\u89e3\u3057\u305f\u3044<\/b><\/li>\n\n\n\n<li><b>\u88c5\u7f6e\u69cb\u6210\u3084\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u5909\u66f4\u3057\u305f\u3044\u3051\u3069\u3001\u3069\u3046\u3057\u305f\u3089\u3088\u3044\u304b\u4e0d\u5b89<\/b><\/li>\n\n\n\n<li><b>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u3082\u3063\u3068\u4f7f\u3044\u3053\u306a\u3057\u305f\u3044\u3001\u3082\u3063\u3068\u6d3b\u7528\u3057\u305f\u3044<\/b><\/li>\n<\/ul>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u62bc\u51fa\u6a5f-\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc-\u306e\u4ed5\u7d44\u307f\">\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u4ed5\u7d44\u307f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u3001\u5186\u7b52\u5f62\u306e\u30d0\u30ec\u30eb\u5185\u3067\u56de\u8ee2\u3059\u308b1\u3064\u4ee5\u4e0a\u306e\u30a2\u30eb\u30ad\u30e1\u30c7\u30b9\u30b9\u30af\u30ea\u30e5\u30fc\u3067\u69cb\u6210\u3055\u308c\u308b\u88c5\u7f6e\u3067\u3059\u3002\u6750\u6599\u306f\u30d0\u30ec\u30eb\u306b\u9023\u7d9a\u7684\u306b\u4f9b\u7d66\u3055\u308c\u307e\u3059\u3002\u30db\u30c3\u30c8\u30e1\u30eb\u30c8\u62bc\u51fa\u306e\u5834\u5408\u306f\u52a0\u71b1\u306b\u3088\u3063\u3066\u6eb6\u878d\u3055\u308c\u3001\u6e7f\u5f0f\u62bc\u51fa\u306e\u5834\u5408\u306f\u6eb6\u5a92\u3068\u3068\u3082\u306b\u5206\u6563\u3055\u308c\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u58c1\u9762\u3068\u306e\u9593\u3067\u305b\u3093\u65ad\u3055\u308c\u307e\u3059\u3002<br>\u6700\u7d42\u7684\u306b\u3001\u6d41\u4f53\u6750\u6599\u306f\u5727\u7e2e\u3055\u308c\u3001\u30c0\u30a4\u3092\u901a\u3057\u3066\u7279\u5b9a\u306e\u65ad\u9762\u5f62\u72b6\u3067\u62bc\u3057\u51fa\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"388\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/0758c32f7b441cfb146aaac2d0c98911-1024x388.png\" alt=\"\" class=\"wp-image-19844\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/0758c32f7b441cfb146aaac2d0c98911-1024x388.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/0758c32f7b441cfb146aaac2d0c98911-300x114.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/0758c32f7b441cfb146aaac2d0c98911-768x291.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/0758c32f7b441cfb146aaac2d0c98911-1536x582.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/0758c32f7b441cfb146aaac2d0c98911-2048x776.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6750\u6599\u304c\u901a\u904e\u3059\u308b\u30d0\u30ec\u30eb\u3084\u30c0\u30a4\u306f\u6e29\u5ea6\u306e\u5236\u5fa1\u304c\u53ef\u80fd\u3067\u3059\u3002\u307e\u305f\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u56de\u8ee2\u3084\u6750\u6599\u306e\u4f9b\u7d66\u901f\u5ea6\u3082\u5236\u5fa1\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6eb6\u878d\u6e29\u5ea6\uff08T\uff09\u3084\u6eb6\u878d\u5727\u529b\uff08P\uff09\u306f\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u30d0\u30ec\u30eb\u306e\u5404\u4f4d\u7f6e\u3084\u30c0\u30a4\u3067\u6e2c\u5b9a\u3067\u304d\u307e\u3059\u3002<br>\u30c8\u30eb\u30af\uff08M\uff09\u306f\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u30c9\u30e9\u30a4\u30d6\u30b7\u30e3\u30d5\u30c8\u3067\u6e2c\u5b9a\u3055\u308c\u307e\u3059\u3002<br>\u306a\u304a\u3001\u3053\u308c\u3089\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306f\u76f4\u63a5\u5236\u5fa1\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u304c\u3001\u8a2d\u5b9a\u6e29\u5ea6\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u901f\u5ea6\u3001\u304a\u3088\u3073\u6750\u6599\u306e\u4f9b\u7d66\u901f\u5ea6\u306b\u4f9d\u5b58\u3057\u3066\u5909\u5316\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u7a2e\u985e\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u7a2e\u985e<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e00\u8ef8\u30bf\u30a4\u30d7\">\u4e00\u8ef8\u30bf\u30a4\u30d7<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30af\u30ea\u30e5\u30fc\u304c1\u672c\u306e\u30bf\u30a4\u30d7\u3067\u3001\u4ed6\u306e\u30bf\u30a4\u30d7\u306b\u6bd4\u3079\u308b\u3068\u30b7\u30f3\u30d7\u30eb\u306a\u69cb\u9020\u3067\u3059\u3002<br>\u8907\u6570\u306e\u6750\u6599\u3092\u5747\u8cea\u306b\u6df7\u932c\u3059\u308b\u305f\u3081\u306e\u30b3\u30f3\u30d1\u30a6\u30f3\u30c9\u80fd\u529b\u304c\u6975\u3081\u3066\u4f4e\u3044\u305f\u3081\u3001\u6750\u6599\u306e\u958b\u767a\u3001\u88fd\u9020\u306b\u304a\u3044\u3066\u306f\u62bc\u51fa\u6210\u5f62\u306b\u7528\u9014\u304c\u9650\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7279\u6b8a\u30bf\u30a4\u30d7\">\u7279\u6b8a\u30bf\u30a4\u30d7<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">3\u672c\u4ee5\u4e0a\u306e\u30b9\u30af\u30ea\u30e5\u30fc\u3092\u6301\u3064\u3082\u306e\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u6b8a\u306a\u69cb\u9020\u306e\u305f\u3081\u3001\u88c5\u7f6e\u304c\u9ad8\u984d\u3067\u3001\u53d6\u308a\u6271\u3044\u304c\u8907\u96d1\u306b\u306a\u3063\u3066\u3057\u307e\u3046\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u30bf\u30a4\u30d7\">\u4e8c\u8ef8\u30bf\u30a4\u30d7<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6587\u5b57\u901a\u308a\u4e8c\u672c\u306e\u30b9\u30af\u30ea\u30e5\u30fc\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u69cb\u9020\u3067\u3059\u3002<br>2\u672c\u306e\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u56de\u8ee2\u65b9\u5411\u306e\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308a\u3001\u540c\u65b9\u5411\u56de\u8ee2\u3068\u7570\u65b9\u5411\u56de\u8ee2\u304c\u3042\u308a\u307e\u3059\u3002\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u69cb\u9020\u30822\u7a2e\u985e\u306e\u30bf\u30a4\u30d7\u304c\u3042\u308a\u307e\u3059\u3002\u6839\u5143\u304b\u3089\u5148\u7aef\u307e\u3067\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u76f4\u5f84\u304c\u540c\u3058\u30d1\u30e9\u30ec\u30eb\u578b\u3068\u3001\u6839\u5143\u304b\u3089\u5148\u7aef\u306b\u304b\u3051\u3066\u76f4\u5f84\u304c\u5c0f\u3055\u304f\u306a\u3063\u3066\u3044\u304f\u30b3\u30cb\u30ab\u30eb\u578b\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"833\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/a934c860c2b752d056ae5b3741814f64-1024x833.png\" alt=\"\" class=\"wp-image-19846\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/a934c860c2b752d056ae5b3741814f64-1024x833.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/a934c860c2b752d056ae5b3741814f64-300x244.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/a934c860c2b752d056ae5b3741814f64-768x625.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/a934c860c2b752d056ae5b3741814f64-1536x1249.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/a934c860c2b752d056ae5b3741814f64-2048x1666.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u304c\u6700\u3082\u591a\u304f\u4f7f\u308f\u308c\u3066\u304a\u308a\u3001\u3053\u306e\u65b9\u5f0f\u3092\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3068\u547c\u3093\u3067\u3044\u308b\u3053\u3068\u304c\u4e00\u822c\u7684\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u62bc\u51fa\u6a5f-\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc-\u306e\u7279\u9577\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u7279\u9577<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u540c\u65b9\u5411\u56de\u8ee2\u3068\u7570\u65b9\u5411\u56de\u8ee2\">\u540c\u65b9\u5411\u56de\u8ee2\u3068\u7570\u65b9\u5411\u56de\u8ee2<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u540c\u65b9\u5411\u56de\u8ee2\u30bf\u30a4\u30d7\u306f\u3001\u6750\u6599\u306b\u5f37\u3044\u305b\u3093\u65ad\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u30b3\u30f3\u30d1\u30a6\u30f3\u30c9\u80fd\u529b\u304c\u975e\u5e38\u306b\u512a\u308c\u3066\u3044\u307e\u3059\u3002\u7570\u65b9\u5411\u56de\u8ee2\u30bf\u30a4\u30d7\u306f\u3001\u6750\u6599\u306b\u9ad8\u3044\u5727\u529b\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u305b\u3093\u65ad\u529b\u306f\u5f31\u304f\u3001\u30b3\u30f3\u30d1\u30a6\u30f3\u30c9\u80fd\u529b\u304c\u4f4e\u3044\u3068\u3044\u3046\u7279\u5fb4\u304c\u3042\u308a\u307e\u3059\u3002\u30b3\u30f3\u30d1\u30a6\u30f3\u30c9\u80fd\u529b\u306f\u4f4e\u3044\u3082\u306e\u306e\u3001\u305b\u3093\u65ad\u529b\u304c\u5f31\u3044\u3086\u3048\u306b\u305b\u3093\u65ad\u767a\u71b1\u3082\u4f4e\u304f\u3001\u71b1\u306b\u5f31\u3044\u6750\u6599\u306e\u6df7\u932c\u306b\u9069\u3057\u3066\u3044\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u30d1\u30e9\u30ec\u30eb\u578b\u3068\u30b3\u30cb\u30ab\u30eb\u578b\">\u30d1\u30e9\u30ec\u30eb\u578b\u3068\u30b3\u30cb\u30ab\u30eb\u578b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d1\u30e9\u30ec\u30eb\u578b\u306f\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u69cb\u9020\u3092\u30bb\u30b0\u30e1\u30f3\u30c8\u5316\u3001\u3064\u307e\u308a\u3001\u7d30\u304b\u306a\u90e8\u54c1\u3092\u3064\u306a\u3052\u3066\u3044\u304f\u3053\u3068\u3067\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u30c7\u30b6\u30a4\u30f3\u3092\u5909\u66f4\u3067\u304d\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u6750\u6599\u3084\u76ee\u7684\u306b\u5fdc\u3058\u305f\u6700\u9069\u5316\u3084\u5fdc\u7528\u7bc4\u56f2\u304c\u5e83\u304c\u308a\u307e\u3059\u3002<br>\u30b3\u30cb\u30ab\u30eb\u578b\u306f\u5148\u7aef\u306b\u5411\u304b\u3063\u3066\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u5f84\u304c\u5c0f\u3055\u304f\u306a\u3063\u3066\u3044\u308b\u69cb\u9020\u306a\u306e\u3067\u3001\u5148\u7aef\u306b\u5411\u304b\u3063\u3066\u9ad8\u3044\u5727\u529b\u3092\u304b\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u5186\u9310\u5f62\u306e\u69cb\u9020\u306e\u305f\u3081\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u3092\u30bb\u30b0\u30e1\u30f3\u30c8\u5316\u3059\u308b\u3053\u3068\u304c\u96e3\u3057\u304f\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u76f4\u5f84\u306b\u5bfe\u3057\u3066\u9577\u3055\u304c\u77ed\u3044\u305f\u3081\u3001\u62e1\u5f35\u6027\u3084\u6a5f\u80fd\u6027\u306f\u30d1\u30e9\u30ec\u30eb\u578b\u306b\u52a3\u308a\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u77ed\u3055\u3068\u3044\u3046\u7279\u5fb4\u3092\u751f\u304b\u3057\u3001\u88c5\u7f6e\u306e\u5c0f\u578b\u5316\u306b\u3088\u308b\u5fae\u91cf\u3067\u306e\u6df7\u932c\u3084\u30d0\u30a4\u30d1\u30b9\u6d41\u8def\u306e\u4f75\u8a2d\u306b\u3088\u308b\u9084\u6d41\u30d0\u30c3\u30c1\u6df7\u7df4\u3092\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u7279\u9577\u306b\u3088\u308a\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u304c\u6700\u3082\u591a\u304f\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306f\u6750\u6599\u306b\u5f37\u3044\u305b\u3093\u65ad\u3092\u304b\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u9ad8\u3044\u5206\u6563\u6027\u3084\u5206\u914d\u6027\u3092\u5fc5\u8981\u3068\u3059\u308b\u6750\u6599\u306e\u4f5c\u6210\u306b\u5411\u3044\u3066\u304a\u308a\u3001\u6750\u6599\u306e\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u3068\u62bc\u51fa\u6210\u578b\u30921\u53f0\u306e\u88c5\u7f6e\u3067\u540c\u6642\u306b\u9023\u7d9a\u7684\u306b\u884c\u3048\u307e\u3059\u3002\u6e29\u5ea6\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u56de\u8ee2\u901f\u5ea6\u3001\u6750\u6599\u4f9b\u7d66\u901f\u5ea6\u306e\u5236\u5fa1\u3084\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u69cb\u6210\u3001\u30c0\u30a4\u306e\u5f62\u72b6\u5909\u66f4\u3082\u5bb9\u6613\u306a\u3053\u3068\u304b\u3089\u3001\u3055\u307e\u3056\u307e\u306a\u5206\u91ce\u3067\u306e\u6750\u6599\u306e\u6539\u8cea\u3001\u52a0\u5de5\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u95a2\u9023\u60c5\u5831\">\u95a2\u9023\u60c5\u5831<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment.html?CID=twin_screw_extrusion_extruder_cad_25011_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u304a\u3088\u3073\u6df7\u932c\u62bc\u51fa<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/resources.html#e-learning?CID=twin_screw_extrusion_extruder_cad_25011_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3064\u3044\u3066\u5b66\u3079\u308be-learning<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u88fd\u54c1\u3092\u53d6\u308a\u6271\u3063\u3066\u3044\u307e\u3059\u3002\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3053\u3061\u3089\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/extruder.html?CID=twin_screw_extrusion_extruder_cad_25011_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba-\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\uff0f\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/?CID=twin_screw_extrusion_extruder_cad_25011_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/?CID=twin_screw_extrusion_extruder_cad_25011_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780 \u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9<\/a><\/li>\n<\/ul>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3001\u30b4\u30e0\u3001\u98df\u54c1\u3001\u98fc\u6599\u3001\u533b\u85ac\u54c1\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5206\u91ce\u3067\u306e\u6750\u6599\u6539\u8cea\u3001\u52a0\u5de5\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1<\/p>\n","protected":false},"author":975,"featured_media":19869,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155],"tags":[234,242,233],"division":[],"class_list":["post-19837","post","type-post","status-publish","format-standard","has-post-thumbnail","category-else","tag-extruder","tag-extruder-basic","tag-233","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577\" \/>\n<meta property=\"og:description\" content=\"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3001\u30b4\u30e0\u3001\u98df\u54c1\u3001\u98fc\u6599\u3001\u533b\u85ac\u54c1\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5206\u91ce\u3067\u306e\u6750\u6599\u6539\u8cea\u3001\u52a0\u5de5\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-03-05T08:59:56+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-12T08:28:07+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\" \/>\n\t<meta property=\"og:image:width\" content=\"778\" \/>\n\t<meta property=\"og:image:height\" content=\"582\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577\",\"datePublished\":\"2025-03-05T08:59:56+00:00\",\"dateModified\":\"2025-11-12T08:28:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/\"},\"wordCount\":6,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"keywords\":[\"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\",\"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8\",\"\u4e8c\u8ef8\u62bc\u51fa\"],\"articleSection\":[\"\u305d\u306e\u4ed6\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/\",\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"datePublished\":\"2025-03-05T08:59:56+00:00\",\"dateModified\":\"2025-11-12T08:28:07+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"width\":778,\"height\":582},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-extruder-cad-25011\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/","og_locale":"ja_JP","og_type":"article","og_title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577","og_description":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3001\u30b4\u30e0\u3001\u98df\u54c1\u3001\u98fc\u6599\u3001\u533b\u85ac\u54c1\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5206\u91ce\u3067\u306e\u6750\u6599\u6539\u8cea\u3001\u52a0\u5de5\u306b\u5229\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-03-05T08:59:56+00:00","article_modified_time":"2025-11-12T08:28:07+00:00","og_image":[{"width":778,"height":582,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577","datePublished":"2025-03-05T08:59:56+00:00","dateModified":"2025-11-12T08:28:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/"},"wordCount":6,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","keywords":["\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc","\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8","\u4e8c\u8ef8\u62bc\u51fa"],"articleSection":["\u305d\u306e\u4ed6"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/","name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","datePublished":"2025-03-05T08:59:56+00:00","dateModified":"2025-11-12T08:28:07+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","width":778,"height":582},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780\uff1a\u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"\u305d\u306e\u4ed6"}],"post_tag":[{"value":234,"label":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc"},{"value":242,"label":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8"},{"value":233,"label":"\u4e8c\u8ef8\u62bc\u51fa"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png",760,569,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":155,"name":"\u305d\u306e\u4ed6","slug":"else","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":63,"filter":"raw","meta":[],"cat_ID":155,"category_count":63,"category_description":"","cat_name":"\u305d\u306e\u4ed6","category_nicename":"else","category_parent":0}],"tag_info":[{"term_id":234,"name":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc","slug":"extruder","term_group":0,"term_taxonomy_id":234,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":242,"name":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8","slug":"extruder-basic","term_group":0,"term_taxonomy_id":242,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw","meta":[]},{"term_id":233,"name":"\u4e8c\u8ef8\u62bc\u51fa","slug":"%e4%ba%8c%e8%bb%b8%e6%8a%bc%e5%87%ba","term_group":0,"term_taxonomy_id":233,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/19837","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=19837"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/19837\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/19869"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=19837"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=19837"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=19837"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=19837"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}