{"id":20248,"date":"2025-04-07T10:05:18","date_gmt":"2025-04-07T01:05:18","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=20248"},"modified":"2025-08-14T18:55:33","modified_gmt":"2025-08-14T09:55:33","slug":"battery-manufacturing-battery-development-cad-25021","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/","title":{"rendered":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u3001\u643a\u5e2f\u6a5f\u5668\u306e\u9032\u5316\u306b\u5f93\u3044\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u52b9\u7387\u306e\u5411\u4e0a\u3068\u74b0\u5883\u4fdd\u8b77\u3092\u4e21\u7acb\u3057\u305f\u30d0\u30c3\u30c6\u30ea\u30fc\u3068\u305d\u306e\u88fd\u9020\u65b9\u6cd5\u306e\u958b\u767a\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u3053\u306e\u300c\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u300d\u3067\u306f\u3001\u5f93\u6765\u306e\u96fb\u6975\u88fd\u9020\u624b\u6cd5\u3068\u306e\u6bd4\u8f03\u3084\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u308b\u3053\u3068\u306e\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\"><strong>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><b>\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306e\u52b9\u7387\u5316\u3001\u54c1\u8cea\u5b89\u5b9a\u5316\u3092\u884c\u3044\u305f\u3044<\/b><\/li>\n\n\n\n<li><b>\u7814\u7a76\u958b\u767a\u3092\u52a0\u901f\u3001\u751f\u7523\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u30c4\u30fc\u30eb\u3092\u63a2\u3057\u3066\u3044\u308b<\/b><\/li>\n\n\n\n<li><b>\u74b0\u5883\u3084\u30b3\u30b9\u30c8\u306b\u914d\u616e\u3057\u305f\u3001\u65b0\u305f\u306a\u88fd\u9020\u624b\u6cd5\u3092\u958b\u767a\u3057\u305f\u3044<\/b><\/li>\n<\/ul>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u521d\u56de\u306f\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3044\u3066\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u3069\u306e\u3088\u3046\u306b\u5229\u7528\u3067\u304d\u308b\u304b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u5229\u7528\">\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u5229\u7528<\/h2>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large wp-image-20249\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"490\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ad71c2596736847ca44941af47b51b53-1024x490.png\" alt=\"\" class=\"wp-image-20249\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ad71c2596736847ca44941af47b51b53-1024x490.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ad71c2596736847ca44941af47b51b53-300x144.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ad71c2596736847ca44941af47b51b53-768x368.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ad71c2596736847ca44941af47b51b53-1536x736.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ad71c2596736847ca44941af47b51b53-2048x981.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u5229\u7528<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u306e\u56f3\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306e\u3044\u304f\u3064\u304b\u306e\u5de5\u7a0b\u3067\u5229\u7528\u3059\u308b\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\n<ul class=\"wp-block-list\">\n<li><b>\u30b0\u30e9\u30d5\u30a1\u30a4\u30c8\u88fd\u9020<\/b><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30e9\u30d5\u30a1\u30a4\u30c8\u3068\u4ed6\u306e\u967d\u6975\u6750\u6599\u3068\u306e\u6df7\u5408\u9020\u7c92\u306b\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u56f3\u306e\u5de6\u5074\u306e\u5199\u771f\u306f\u3001\u958b\u653e\u62bc\u51fa\u578b\u306e\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3068\u3053\u308c\u306b\u3088\u3063\u3066\u9020\u7c92\u3055\u308c\u305f\u30ab\u30fc\u30dc\u30f3\u30d6\u30e9\u30c3\u30af\u30d1\u30a6\u30c0\u30fc\u3067\u3059\u3002\u9020\u7c92\u3055\u308c\u305f\u30ab\u30fc\u30dc\u30f3\u30d6\u30e9\u30c3\u30af\u30d1\u30a6\u30c0\u30fc\u306f\u7c89\u3058\u3093\u304c\u5c11\u306a\u304f\u3001\u9ad8\u3044\u6d41\u52d5\u6027\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u6df7\u5408\u9020\u7c92\u306f\u3001\u7121\u6eb6\u5a92\u96fb\u6975\u30da\u30fc\u30b9\u30c8\u306e\u88fd\u9020\u306b\u3082\u9069\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\n<ul class=\"wp-block-list\">\n<li><b>\u30bb\u30d1\u30ec\u30fc\u30bf\u30fc\u88fd\u9020<\/b><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u30bb\u30d1\u30ec\u30fc\u30bf\u30fc\u30d5\u30a9\u30a4\u30eb\u306f\u62bc\u51fa\u6210\u5f62\u306b\u3088\u308a\u88fd\u9020\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u88fd\u9020\u30d7\u30ed\u30bb\u30b9\u306f\u3059\u3067\u306b\u958b\u767a\u3001\u78ba\u7acb\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3001\u5168\u56fa\u4f53\u96fb\u6c60\u306a\u3069\u306e\u65b0\u3057\u3044\u30b3\u30f3\u30bb\u30d7\u30c8\u306e\u30d0\u30c3\u30c6\u30ea\u30fc\u3067\u306f\u3001\u65b0\u305f\u306a\u30b2\u30eb\u30dd\u30ea\u30de\u30fc\u30bb\u30d1\u30ec\u30fc\u30bf\u30fc\u3084\u96fb\u89e3\u8cea\u306e\u958b\u767a\u304c\u9032\u3093\u3067\u304a\u308a\u3001\u30e9\u30dc\u30b9\u30b1\u30fc\u30eb\u306e\u5c0f\u578b\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u304c\u5f79\u7acb\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\n<ul class=\"wp-block-list\">\n<li><b>\u96fb\u6975\u88fd\u9020<\/b><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u96fb\u6975\u306e\u88fd\u9020\u306b\u304a\u3044\u3066\u306f\u3001\u9670\u6975\u3084\u967d\u6975\u306b\u7528\u3044\u308b\u30b9\u30e9\u30ea\u30fc\u306e\u9023\u7d9a\u6df7\u5408\u306b\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u304c\u5f79\u7acb\u3061\u307e\u3059\u3002\u5f93\u6765\u3001\u96fb\u6975\u30da\u30fc\u30b9\u30c8\u3092\u6df7\u5408\u3059\u308b\u305f\u3081\u306b\u30d0\u30c3\u30c1\u5f0f\u306e\u30d7\u30e9\u30cd\u30bf\u30ea\u30fc\u30df\u30ad\u30b5\u30fc\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u308c\u3092\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u7f6e\u304d\u63db\u3048\u308b\u3053\u3068\u3067\u5927\u304d\u306a\u30a2\u30c9\u30d0\u30f3\u30c6\u30fc\u30b8\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30d0\u30c3\u30c6\u30ea\u30fc\u7814\u7a76\u958b\u767a\u306b\u304a\u3051\u308b\u30e9\u30dc\u30b9\u30b1\u30fc\u30eb\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u5229\u70b9\">\u30d0\u30c3\u30c6\u30ea\u30fc\u7814\u7a76\u958b\u767a\u306b\u304a\u3051\u308b\u30e9\u30dc\u30b9\u30b1\u30fc\u30eb\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u5229\u70b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u306b\u7814\u7a76\u958b\u767a\u306e\u6bb5\u968e\u306b\u304a\u3044\u3066\u306f\u5c0f\u578b\u3067\u5353\u4e0a\u306b\u8a2d\u7f6e\u3067\u304d\u308b\u30e9\u30dc\u30b9\u30b1\u30fc\u30eb\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u304c\u6709\u7528\u3067\u3059\u3002\u30e9\u30dc\u30b9\u30b1\u30fc\u30eb\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u657010 g\uff5e\u3068\u3044\u3046\u5fae\u91cf\u3067\u306e\u6df7\u932c\u304c\u53ef\u80fd\u306a\u305f\u3081\u3001\u5c11\u91cf\u591a\u54c1\u7a2e\u306e\u8a66\u4f5c\u3084\u3001\u9ad8\u4fa1\u306a\u6750\u6599\u3092\u52b9\u7387\u7684\u306b\u5229\u7528\u3059\u308b\u3053\u3068\u306b\u5411\u3044\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u5c0f\u578b\u306e\u88c5\u7f6e\u3092\u30b0\u30ed\u30fc\u30d6\u30dc\u30c3\u30af\u30b9\u5185\u3067\u8a2d\u7f6e\u30fb\u904b\u7528\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u53b3\u3057\u3044\u88fd\u9020\u74b0\u5883\u3067\u3082\u9ad8\u3044\u5b89\u5168\u6027\u3068\u6027\u80fd\u3092\u767a\u63ee\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-20250\"><img loading=\"lazy\" decoding=\"async\" width=\"423\" height=\"338\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_.png\" alt=\"\" class=\"wp-image-20250\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_.png 423w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_-300x240.png 300w\" sizes=\"auto, (max-width: 423px) 100vw, 423px\" \/><figcaption class=\"wp-element-caption\">\u30b0\u30ed\u30fc\u30d6\u30dc\u30c3\u30af\u30b9<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30ed\u30fc\u30d6\u30dc\u30c3\u30af\u30b9\u306e\u5229\u70b9\u306f\u3001\u9ad8\u4fa1\u306a\u30c9\u30e9\u30a4\u30eb\u30fc\u30e0\u3092\u5fc5\u8981\u3068\u305b\u305a\u306b\u3001\u5c0f\u898f\u6a21\u3067\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u7814\u7a76\u958b\u767a\u3092\u53ef\u80fd\u306b\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u30c9\u30e9\u30a4\u30eb\u30fc\u30e0\u3067\u306e\u64cd\u4f5c\u3068\u306f\u5bfe\u7167\u7684\u306b\u3001\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u304c\u30b0\u30ed\u30fc\u30d6\u30dc\u30c3\u30af\u30b9\u5185\u306b\u8a2d\u7f6e\u3055\u308c\u3066\u3044\u308c\u3070\u3001\u6d17\u6d44\u306e\u305f\u3081\u306b\u88c5\u7f6e\u3092\u5206\u89e3\u3057\u3066\u3082\u3001\u30e9\u30dc\u74b0\u5883\u306b\u30c0\u30b9\u30c8\u3084\u6eb6\u5264\u304c\u6f0f\u308c\u51fa\u3055\u306a\u3044\u3088\u3046\u306b\u4fdd\u305f\u308c\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u6709\u5bb3\u7269\u8cea\u306e\u53d6\u308a\u6271\u3044\u3092\u4f34\u3046\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u64cd\u4f5c\u304c\u3088\u308a\u5b89\u5168\u306b\u306a\u308a\u307e\u3059\u3002\u6750\u6599\u3084\u88c5\u7f6e\u306e\u72b6\u614b\u3082\u3001\u3088\u308a\u5b89\u5b9a\u3055\u305b\u3089\u308c\u308b\u305f\u3081\u3001\u4eba\u306b\u3088\u308b\u6c5a\u67d3\u306e\u5fc3\u914d\u3082\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u6750\u6599\u306e\u958b\u767a\u3001\u88fd\u9020\u306b\u5229\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u5b89\u5168\u6027\u3084\u52b9\u7387\u3001\u751f\u7523\u6027\u3067\u306e\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u6b21\u56de\u304b\u3089\u306f\u96fb\u6975\u6750\u6599\u306e\u88fd\u9020\u306b\u3064\u3044\u3066\u5177\u4f53\u7684\u306a\u4f8b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u95a2\u9023\u60c5\u5831\">\u95a2\u9023\u60c5\u5831<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment.html?CID=battery_manufacturing_battery_development_cad_25021_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u304a\u3088\u3073\u6df7\u932c\u62bc\u51fa<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/resources.html#e-learning?CID=battery_manufacturing_battery_development_cad_25021_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3064\u3044\u3066\u5b66\u3079\u308be-learning<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/?CID=battery_manufacturing_battery_development_cad_25021_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780 \u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u88fd\u54c1\u3092\u53d6\u308a\u6271\u3063\u3066\u3044\u307e\u3059\u3002\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3053\u3061\u3089\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/extruder.html?CID=battery_manufacturing_battery_development_cad_25021_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba-\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\uff0f\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/?CID=battery_manufacturing_battery_development_cad_25021_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780 \u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/?CID=battery_manufacturing_battery_development_cad_25021_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461 \u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f<\/a><\/li>\n<\/ul>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u3001\u643a\u5e2f\u6a5f\u5668\u306e\u9032\u5316\u306b\u5f93\u3044\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u52b9\u7387\u306e\u5411\u4e0a\u3068\u74b0\u5883\u4fdd\u8b77\u3092\u4e21\u7acb\u3057\u305f\u30d0\u30c3\u30c6\u30ea\u30fc\u3068\u305d\u306e\u88fd\u9020\u65b9\u6cd5\u306e\u958b\u767a\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u3053\u306e\u300c\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u300d\u3067\u306f\u3001\u5f93\u6765\u306e\u96fb\u6975\u88fd\u9020\u624b\u6cd5\u3068\u306e<\/p>\n","protected":false},"author":975,"featured_media":20253,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155],"tags":[235,236],"division":[],"class_list":["post-20248","post","type-post","status-publish","format-standard","has-post-thumbnail","category-else","tag-235","tag-battery-development","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u3002\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c1\u56de\u306f\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u5229\u7528\u65b9\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9\" \/>\n<meta property=\"og:description\" content=\"\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u3002\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c1\u56de\u306f\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u5229\u7528\u65b9\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-04-07T01:05:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-14T09:55:33+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2107\" \/>\n\t<meta property=\"og:image:height\" content=\"1117\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"5\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9\",\"datePublished\":\"2025-04-07T01:05:18+00:00\",\"dateModified\":\"2025-08-14T09:55:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/\"},\"wordCount\":3,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"keywords\":[\"\u96fb\u6975\u88fd\u9020\",\"\u96fb\u6c60\u958b\u767a\"],\"articleSection\":[\"\u305d\u306e\u4ed6\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/\",\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"datePublished\":\"2025-04-07T01:05:18+00:00\",\"dateModified\":\"2025-08-14T09:55:33+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"description\":\"\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u3002\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c1\u56de\u306f\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u5229\u7528\u65b9\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"width\":2107,\"height\":1117},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25021\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9 - Learning at the Bench","description":"\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u3002\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c1\u56de\u306f\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u5229\u7528\u65b9\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/","og_locale":"ja_JP","og_type":"article","og_title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9","og_description":"\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u3002\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c1\u56de\u306f\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u5229\u7528\u65b9\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-04-07T01:05:18+00:00","article_modified_time":"2025-08-14T09:55:33+00:00","og_image":[{"width":2107,"height":1117,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"5\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9","datePublished":"2025-04-07T01:05:18+00:00","dateModified":"2025-08-14T09:55:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/"},"wordCount":3,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","keywords":["\u96fb\u6975\u88fd\u9020","\u96fb\u6c60\u958b\u767a"],"articleSection":["\u305d\u306e\u4ed6"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/","name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","datePublished":"2025-04-07T01:05:18+00:00","dateModified":"2025-08-14T09:55:33+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"description":"\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u3002\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u672c\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c1\u56de\u306f\u3001\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u5229\u7528\u65b9\u6cd5\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","width":2107,"height":1117},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"\u305d\u306e\u4ed6"}],"post_tag":[{"value":235,"label":"\u96fb\u6975\u88fd\u9020"},{"value":236,"label":"\u96fb\u6c60\u958b\u767a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch-1024x543.jpg",760,403,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":155,"name":"\u305d\u306e\u4ed6","slug":"else","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":63,"filter":"raw","meta":[],"cat_ID":155,"category_count":63,"category_description":"","cat_name":"\u305d\u306e\u4ed6","category_nicename":"else","category_parent":0}],"tag_info":[{"term_id":235,"name":"\u96fb\u6975\u88fd\u9020","slug":"%e9%9b%bb%e6%a5%b5%e8%a3%bd%e9%80%a0","term_group":0,"term_taxonomy_id":235,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":236,"name":"\u96fb\u6c60\u958b\u767a","slug":"battery-development","term_group":0,"term_taxonomy_id":236,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/20248","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=20248"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/20248\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/20253"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=20248"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=20248"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=20248"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=20248"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}