{"id":20713,"date":"2025-05-01T12:10:11","date_gmt":"2025-05-01T03:10:11","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=20713"},"modified":"2025-11-12T17:28:23","modified_gmt":"2025-11-12T08:28:23","slug":"twin-screw-extrusion-battery-development-cad-25026","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/","title":{"rendered":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u62bc\u51fa\u6210\u5f62\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\"><strong>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><b>\u306a\u3093\u3068\u306a\u304f\u4f7f\u3063\u3066\u3044\u308b\u3051\u308c\u3069\u3001\u3082\u3063\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u3053\u3068\u3092\u7406\u89e3\u3057\u305f\u3044<\/b><\/li>\n\n\n\n<li><b>\u88c5\u7f6e\u69cb\u6210\u3084\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u5909\u66f4\u3057\u305f\u3044\u3051\u3069\u3001\u3069\u3046\u3057\u305f\u3089\u3088\u3044\u304b\u4e0d\u5b89<\/b><\/li>\n\n\n\n<li><b>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u3082\u3063\u3068\u4f7f\u3044\u3053\u306a\u3057\u305f\u3044\u3001\u3082\u3063\u3068\u6d3b\u7528\u3057\u305f\u3044<\/b><\/li>\n<\/ul>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306f\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30d1\u30fc\u30c4\u3067\u3042\u308b\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\u306b\u3064\u3044\u3066\u3001Thermo Scientific\u2122 Process 11\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u4f8b\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full wp-image-20716\"><img loading=\"lazy\" decoding=\"async\" width=\"774\" height=\"581\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_Process-11-05.png\" alt=\"Thermo Scientific\u2122 Process 11\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\" class=\"wp-image-20716\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_Process-11-05.png 774w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_Process-11-05-300x225.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_Process-11-05-768x576.png 768w\" sizes=\"auto, (max-width: 774px) 100vw, 774px\" \/><figcaption class=\"wp-element-caption\"><br>Thermo Scientific\u2122 Process 11\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Process 11\u306f\u5c0f\u578b\u3001\u5353\u4e0a\u306e\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3067\u3059\u3002\u308f\u305a\u304b20 g\u7a0b\u5ea6\u306e\u5c11\u91cf\u306e\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u304b\u3089\u3001\u6700\u59272.5 kg\/h\u7a0b\u5ea6\u306e\u9023\u7d9a\u751f\u7523\u3082\u53ef\u80fd\u3067\u3059\u3002\u30bb\u30b0\u30e1\u30f3\u30c8\u5f0f\u30b9\u30af\u30ea\u30e5\u30fc\u30c7\u30b6\u30a4\u30f3\u3084\u3001\u30be\u30fc\u30f3\u6bce\u306b\u8a2d\u7f6e\u3055\u308c\u305f\u30aa\u30d7\u30b7\u30e7\u30f3\u30dd\u30fc\u30c8\u3084\u6e29\u8abf\u6a5f\u80fd\u3001\u591a\u5f69\u306a\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u306b\u3088\u308a\u3001\u3055\u307e\u3056\u307e\u306a\u6750\u6599\u306e\u6df7\u932c\u3001\u62bc\u51fa\u6210\u578b\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u4ed5\u7d44\u307f\">\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u4ed5\u7d44\u307f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u56f3\u306fProcess 11\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u6a19\u6e96\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u69cb\u6210\u3067\u3059\u3002\u3053\u306e\u69cb\u6210\u3067\u306f\u3001\u71b1\u53ef\u5851\u6027\u6a39\u8102\u306b\u6dfb\u52a0\u5264\u3092\u52a0\u3048\u3066\u6df7\u932c\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u305f\u8a2d\u8a08\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u203b\u753b\u50cf\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u62e1\u5927<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/91d9241e09e984ac595a2c36ef5b8f14-1024x166.png\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"166\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/91d9241e09e984ac595a2c36ef5b8f14-1024x166.png\" alt=\"Process 11\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u6a19\u6e96\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u69cb\u6210\" class=\"wp-image-20717\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/91d9241e09e984ac595a2c36ef5b8f14-1024x166.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/91d9241e09e984ac595a2c36ef5b8f14-300x49.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/91d9241e09e984ac595a2c36ef5b8f14-768x125.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/91d9241e09e984ac595a2c36ef5b8f14-1536x249.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/91d9241e09e984ac595a2c36ef5b8f14-2048x332.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Process 11\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u6a19\u6e96\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u69cb\u6210<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><br>\u30b9\u30af\u30ea\u30e5\u30fc\u306f\u4e3b\u306b3\u3064\u306e\u6a5f\u80fd\u3092\u76ee\u7684\u306b\u5fdc\u3058\u3066\u7d44\u307f\u5408\u308f\u305b\u305f\u8a2d\u8a08\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\n<ul class=\"wp-block-list\">\n<li><b>\u30d5\u30a3\u30fc\u30c9\uff08\u642c\u9001\uff09\u30be\u30fc\u30f3<\/b><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e8c\u91cd\u3089\u305b\u3093\u69cb\u9020\u3092\u6301\u3061\u3001\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u6295\u5165\u3055\u308c\u305f\u6750\u6599\u3092\u30c0\u30a4\u65b9\u5411\u306b\u5411\u304b\u3063\u3066\u904b\u3076\u3068\u3068\u3082\u306b\u3001\u642c\u9001\u65b9\u5411\u306b\u6750\u6599\u3092\u5206\u914d\u3055\u305b\u308b\u5f79\u5272\u3092\u62c5\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\n<ul class=\"wp-block-list\">\n<li><b>\u30df\u30ad\u30b7\u30f3\u30b0\uff08\u6df7\u932c\uff09\u30be\u30fc\u30f3<\/b><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u6955\u5186\u5f62\u306e\u677f\u72b6\u306e\u30a8\u30ec\u30e1\u30f3\u30c8\u304c\u96a3\u540c\u58eb\u3067\u89d2\u5ea6\u3092\u5909\u3048\u3066\u914d\u7f6e\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30be\u30fc\u30f3\u3067\u306f\u3001\u6750\u6599\u3092\u6ede\u7559\u3055\u305b\u3001\u305b\u3093\u65ad\u5fdc\u529b\u3092\u4e0e\u3048\u308b\u5f79\u5272\u3092\u6301\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\n<ul class=\"wp-block-list\">\n<li><b>\u62bc\u51fa\u30be\u30fc\u30f3<\/b><\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u91cd\u3089\u305b\u3093\u69cb\u9020\u3092\u6301\u3061\u3001\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u306b\u5727\u529b\u3092\u304b\u3051\u3066\u3001\u7279\u5b9a\u306e\u5f62\u72b6\u3092\u3057\u305f\u30c0\u30a4\u304b\u3089\u62bc\u3057\u51fa\u3059\u5f79\u5272\u3092\u6301\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u5404\u30be\u30fc\u30f3\u306f\u305d\u308c\u305e\u308c\u306b\u6a5f\u80fd\u3092\u6301\u3063\u305f\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30ec\u30e1\u30f3\u30c8\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u53d6\u308a\u4ed8\u3051\u9806\u5e8f\u3084\u89d2\u5ea6\u3092\u5909\u66f4\u3059\u308b\u3053\u3068\u3067\u3001\u76ee\u7684\u306b\u5408\u3063\u305f\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u69cb\u6210\u3092\u4f5c\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u56f3\u306f\u4ee3\u8868\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30ec\u30e1\u30f3\u30c8\u3067\u3001\u3053\u306e\u307b\u304b\u306b\u3082\u3055\u307e\u3056\u307e\u306a\u5f62\u72b6\u306e\u30a8\u30ec\u30e1\u30f3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large wp-image-20721\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"362\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ef6d164a09d824cefd0b9282e32ced8d-1024x362.png\" alt=\"\u4ee3\u8868\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u5f62\u72b6\" class=\"wp-image-20721\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ef6d164a09d824cefd0b9282e32ced8d-1024x362.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ef6d164a09d824cefd0b9282e32ced8d-300x106.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ef6d164a09d824cefd0b9282e32ced8d-768x272.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ef6d164a09d824cefd0b9282e32ced8d-1536x543.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/ef6d164a09d824cefd0b9282e32ced8d-2048x724.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\"><br>\u4ee3\u8868\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u5f62\u72b6<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><br>\u30df\u30ad\u30b7\u30f3\u30b0\u30be\u30fc\u30f3\u3067\u306f\u6750\u6599\u306b\u305b\u3093\u65ad\u3092\u4e0e\u3048\u308b\u305f\u3081\u3001\u3053\u306e\u30be\u30fc\u30f3\u306e\u69cb\u6210\u304c\u6750\u6599\u306e\u5206\u6563\u6027\u3001\u6df7\u932c\u306e\u54c1\u8cea\u306b\u91cd\u8981\u306a\u8981\u7d20\u3068\u306a\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u56f3\u306f\u30df\u30ad\u30b7\u30f3\u30b0\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u7570\u306a\u308b\u30aa\u30d5\u30bb\u30c3\u30c8\u89d2\u5ea6\u3092\u793a\u3057\u305f\u3082\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large wp-image-20723\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"250\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/62b4c7c3244d2219889fbfbcc53061a8-1024x250.png\" alt=\"\u30df\u30ad\u30b7\u30f3\u30b0\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u7570\u306a\u308b\u30aa\u30d5\u30bb\u30c3\u30c8\u89d2\u5ea6\" class=\"wp-image-20723\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/62b4c7c3244d2219889fbfbcc53061a8-1024x250.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/62b4c7c3244d2219889fbfbcc53061a8-300x73.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/62b4c7c3244d2219889fbfbcc53061a8-768x188.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/62b4c7c3244d2219889fbfbcc53061a8-1536x375.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/62b4c7c3244d2219889fbfbcc53061a8-2048x500.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">\u30df\u30ad\u30b7\u30f3\u30b0\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u7570\u306a\u308b\u30aa\u30d5\u30bb\u30c3\u30c8\u89d2\u5ea6<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u6df7\u932c\u80fd\u529b\u306f\u30aa\u30d5\u30bb\u30c3\u30c8\u89d2\u5ea6\u304c\u5927\u304d\u304f\u306a\u308b\u307b\u3069\u5f37\u304f\u306a\u308a\u307e\u3059\u3002\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u30aa\u30d5\u30bb\u30c3\u30c8\u89d2\u5ea6\u3001\u6570\u3001\u4f4d\u7f6e\u3092\u5909\u66f4\u3059\u308b\u3053\u3068\u3067\u3001\u6df7\u932c\u6761\u4ef6\u3092\u6700\u9069\u5316\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30af\u30ea\u30e5\u30fc\u306e\u9577\u3055\u3082\u91cd\u8981\u306a\u8981\u7d20\u306e\u4e00\u3064\u3067\u3059\u3002\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u30b9\u30af\u30ea\u30e5\u30fc\u9577\u3055\u306f\u76f4\u5f84\u306b\u5bfe\u3059\u308b\u9577\u3055\u306e\u6bd4\u3001L\/D\u3067\u8868\u3055\u308c\u307e\u3059\u3002Process 11\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u5834\u5408\u306f\u5f84\u304c11 mm\u3001\u9577\u3055\u304c440 mm\u306e\u305f\u3081\u3001L\/D = 40\u3068\u306a\u308a\u307e\u3059\u3002L\/D\u306e\u5927\u304d\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u306f\u3001\u3088\u308a\u591a\u304f\u306e\u30a8\u30ec\u30e1\u30f3\u30c8\u3092\u5fc5\u8981\u3068\u3057\u307e\u3059\u304c\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u69cb\u6210\u306e\u9ad8\u3044\u81ea\u7531\u5ea6\u304c\u3001\u3055\u307e\u3056\u307e\u306a\u6750\u6599\u306b\u5bfe\u3059\u308b\u6df7\u932c\u6761\u4ef6\u306e\u6700\u9069\u5316\u3092\u5bb9\u6613\u306b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\">\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u30d0\u30ec\u30eb\u306f\u30b9\u30af\u30ea\u30e5\u30fc\u304c\u683c\u7d0d\u3055\u308c\u308b\u5186\u7b52\u5f62\u69cb\u9020\u3067\u3059\u3002<br>\u3053\u306e\u30d0\u30ec\u30eb\u306f\u3001\u96fb\u4f4d\u5dee\u306b\u3088\u308b\u8150\u98df\u3092\u9632\u3050\u305f\u3081\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u540c\u3058\u91d1\u5c5e\u3067\u4f5c\u3089\u308c\u308b\u3053\u3068\u304c\u57fa\u672c\u3067\u3059\u3002\u30b9\u30af\u30ea\u30e5\u30fc\u306b\u6bd4\u3079\u308b\u3068\u4e00\u898b\u30b7\u30f3\u30d7\u30eb\u306a\u69cb\u9020\u3067\u3059\u304c\u3001\u6df7\u932c\u306e\u54c1\u8cea\u3084\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u6a5f\u80fd\u62e1\u5f35\u6027\u306b\u5927\u304d\u304f\u5f71\u97ff\u3059\u308b\u30d1\u30fc\u30c4\u3067\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u6280\u8853\u3084\u6a5f\u80fd\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u306e\u30af\u30ea\u30a2\u30e9\u30f3\u30b9\uff08\u9699\u9593\uff09\u3092\u4e00\u5b9a\u306b\u4fdd\u3064\u9ad8\u3044\u8a2d\u8a08\u30fb\u88fd\u4f5c\u7cbe\u5ea6<\/li>\n\n\n\n<li>\u6750\u6599\u306b\u71b1\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u4e0e\u3048\u308b\u305f\u3081\u306e\u6b63\u78ba\u3067\u7d20\u65e9\u3044\u6e29\u8abf\u6a5f\u80fd<\/li>\n\n\n\n<li>\u8010\u5727\u3001\u8010\u71b1\u3001\u8010\u98df\u3001\u8010\u6469\u8017\u6027\u80fd<\/li>\n\n\n\n<li>\u6750\u6599\u6dfb\u52a0\uff08\u30b5\u30a4\u30c9\u30d5\u30a3\u30fc\u30c9\uff09\u3084\u8131\u6c17\uff08\u30d9\u30f3\u30c8\uff09\u306e\u305f\u3081\u306e\u62e1\u5f35\u6027<\/li>\n\n\n\n<li>\u5206\u89e3\u3068\u6d17\u6d44\u306e\u3057\u3084\u3059\u3055<\/li>\n<\/ul>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u203b\u753b\u50cf\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u62e1\u5927<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter\"><a href=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/bf2355984361fa6d45ad1c3494fc0c24-1024x767.png\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"767\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/bf2355984361fa6d45ad1c3494fc0c24-1024x767.png\" alt=\"Process 11\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u30d0\u30ec\u30eb\u3068\u30b9\u30af\u30ea\u30e5\u30fc\" class=\"wp-image-20724\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/bf2355984361fa6d45ad1c3494fc0c24-1024x767.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/bf2355984361fa6d45ad1c3494fc0c24-300x225.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/bf2355984361fa6d45ad1c3494fc0c24-768x575.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/bf2355984361fa6d45ad1c3494fc0c24-1536x1150.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/bf2355984361fa6d45ad1c3494fc0c24-2048x1534.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\">Process 11\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u30d0\u30ec\u30eb\u3068\u30b9\u30af\u30ea\u30e5\u30fc<\/figcaption><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u306e\u56f3\u306fProcess 11\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u30d0\u30ec\u30eb\u3092\u5206\u89e3\u3057\u305f\u69d8\u5b50\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u4e0a\u4e0b\u306b\u5206\u5272\u3059\u308b\u3053\u3068\u3067\u3001\u6d17\u6d44\u304c\u5bb9\u6613\u306b\u306a\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u30d0\u30ec\u30eb\u5185\u3067\u306e\u6750\u6599\u306e\u72b6\u614b\u3092\u76f4\u63a5\u89b3\u5bdf\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30d0\u30ec\u30eb\u306b\u306f\u591a\u6570\u306e\u30aa\u30d7\u30b7\u30e7\u30f3\u30dd\u30fc\u30c8\u3092\u8a2d\u5b9a\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u30dd\u30fc\u30c8\u6bce\u306b\u5206\u5272\u3055\u308c\u3066\u3044\u308b\u30be\u30fc\u30f3\u3067\u306f\u500b\u5225\u306b\u6e29\u8abf\u8a2d\u5b9a\u304c\u3067\u304d\u3001\u3053\u308c\u306b\u3088\u308a\u591a\u69d8\u306a\u6df7\u932c\u51e6\u65b9\u306b\u5bfe\u5fdc\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306b\u3001\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u304a\u3051\u308b\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306f\u3001\u6df7\u932c\u3068\u62bc\u51fa\u6210\u578b\u306e\u54c1\u8cea\u306b\u76f4\u63a5\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u30d1\u30fc\u30c4\u3067\u3059\u3002\u6750\u6599\u3084\u76ee\u7684\u306b\u5fdc\u3058\u305f\u9069\u5207\u306a\u6750\u8cea\u3084\u69cb\u6210\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3042\u308a\u3001\u7279\u306b\u591a\u69d8\u306a\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u6761\u4ef6\u3092\u8a66\u3059\u3053\u3068\u304c\u5fc5\u8981\u306a\u7814\u7a76\u958b\u767a\u306b\u5229\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u6a5f\u80fd\u3084\u62e1\u5f35\u6027\u3082\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u95a2\u9023\u60c5\u5831\">\u95a2\u9023\u60c5\u5831<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment.html?CID=twin_screw_extrusion_battery_development_cad_25026_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u304a\u3088\u3073\u6df7\u932c\u62bc\u51fa<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/resources.html#e-learning?CID=twin_screw_extrusion_battery_development_cad_25026_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3064\u3044\u3066\u5b66\u3079\u308be-learning<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<br>\u5f53\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u88fd\u54c1\u3092\u53d6\u308a\u6271\u3063\u3066\u3044\u307e\u3059\u3002\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3053\u3061\u3089\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/extruder.html?CID=twin_screw_extrusion_battery_development_cad_25026_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba-\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\uff0f\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089<\/h4>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/?CID=twin_screw_extrusion_battery_development_cad_25026_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780 \u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/?CID=twin_screw_extrusion_battery_development_cad_25026_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780 \u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9<\/a><\/li>\n<\/ul>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<br>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u62bc\u51fa\u6210\u5f62\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002 \u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u4eca\u56de\u306f\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30d1\u30fc\u30c4\u3067\u3042\u308b\u30b9\u30af\u30ea\u30e5\u30fc<\/p>\n","protected":false},"author":975,"featured_media":20715,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155],"tags":[242,233,236],"division":[],"class_list":["post-20713","post","type-post","status-publish","format-standard","has-post-thumbnail","category-else","tag-extruder-basic","tag-233","tag-battery-development","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\u3092\u3001\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u4f8b\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\" \/>\n<meta property=\"og:description\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\u3092\u3001\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u4f8b\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-05-01T03:10:11+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-12T08:28:23+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1218\" \/>\n\t<meta property=\"og:image:height\" content=\"911\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"8\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\",\"datePublished\":\"2025-05-01T03:10:11+00:00\",\"dateModified\":\"2025-11-12T08:28:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/\"},\"wordCount\":27,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png\",\"keywords\":[\"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8\",\"\u4e8c\u8ef8\u62bc\u51fa\",\"\u96fb\u6c60\u958b\u767a\"],\"articleSection\":[\"\u305d\u306e\u4ed6\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/\",\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png\",\"datePublished\":\"2025-05-01T03:10:11+00:00\",\"dateModified\":\"2025-11-12T08:28:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"description\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\u3092\u3001\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u4f8b\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png\",\"width\":1218,\"height\":911},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25026\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f - Learning at the Bench","description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\u3092\u3001\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u4f8b\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/","og_locale":"ja_JP","og_type":"article","og_title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f","og_description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\u3092\u3001\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u4f8b\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-05-01T03:10:11+00:00","article_modified_time":"2025-11-12T08:28:23+00:00","og_image":[{"width":1218,"height":911,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"8\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f","datePublished":"2025-05-01T03:10:11+00:00","dateModified":"2025-11-12T08:28:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/"},"wordCount":27,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png","keywords":["\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8","\u4e8c\u8ef8\u62bc\u51fa","\u96fb\u6c60\u958b\u767a"],"articleSection":["\u305d\u306e\u4ed6"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/","name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png","datePublished":"2025-05-01T03:10:11+00:00","dateModified":"2025-11-12T08:28:23+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u4e2d\u5fc3\u7684\u306a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f\u3092\u3001\u30d1\u30e9\u30ec\u30eb\u578b\u540c\u65b9\u5411\u56de\u8ee2\u4e8c\u8ef8\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u4f8b\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png","width":1218,"height":911},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461\uff1a\u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"\u305d\u306e\u4ed6"}],"post_tag":[{"value":242,"label":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8"},{"value":233,"label":"\u4e8c\u8ef8\u62bc\u51fa"},{"value":236,"label":"\u96fb\u6c60\u958b\u767a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch-1024x766.png",760,569,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":6,"category_info":[{"term_id":155,"name":"\u305d\u306e\u4ed6","slug":"else","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":63,"filter":"raw","meta":[],"cat_ID":155,"category_count":63,"category_description":"","cat_name":"\u305d\u306e\u4ed6","category_nicename":"else","category_parent":0}],"tag_info":[{"term_id":242,"name":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8","slug":"extruder-basic","term_group":0,"term_taxonomy_id":242,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw","meta":[]},{"term_id":233,"name":"\u4e8c\u8ef8\u62bc\u51fa","slug":"%e4%ba%8c%e8%bb%b8%e6%8a%bc%e5%87%ba","term_group":0,"term_taxonomy_id":233,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]},{"term_id":236,"name":"\u96fb\u6c60\u958b\u767a","slug":"battery-development","term_group":0,"term_taxonomy_id":236,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/twin-screw-extrusion-battery-development-cad-25026_eyecatch.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/20713","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=20713"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/20713\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/20715"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=20713"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=20713"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=20713"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=20713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}