{"id":21407,"date":"2025-06-12T15:15:39","date_gmt":"2025-06-12T06:15:39","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=21407"},"modified":"2025-06-12T15:15:43","modified_gmt":"2025-06-12T06:15:43","slug":"protein-expression-cloning-bid-ts-mbr-25035","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/","title":{"rendered":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u3055\u3066\u3001\u7b2c4\u56de\u3067\u3059\u3002\u7b2c3\u56de\u306b\u5f15\u304d\u7d9a\u304d\u3001\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u54fa\u4e73\u985e\u7d30\u80de\u4ee5\u5916\u306e\u767a\u73fe\u7cfb\u7528\u30d9\u30af\u30bf\u30fc\u306e\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u6700\u521d\u306b\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u3064\u3044\u3066\u3067\u304d\u308b\u3060\u3051\u7c21\u5358\u306b\u307e\u3068\u3081\u305f\u8cc7\u6599\u3092\u8f09\u305b\u307e\u3059\u306e\u3067\u5b9f\u4f8b\u3068\u4e00\u7dd2\u306b\u3053\u3061\u3089\u3092\u898b\u3066\u3044\u305f\u3060\u304f\u3068\u3088\u308a\u308f\u304b\u308a\u3084\u3059\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u3082\u3057\u60c5\u5831\u304c\u8db3\u308a\u306a\u3044\u5834\u5408\u306f\u6700\u5f8c\u306b\u904e\u53bb\u30d6\u30ed\u30b0\u306e\u30ea\u30f3\u30af\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u306e\u3067\u3001\u3053\u3061\u3089\u3082\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u3064\u3044\u3066\">\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u3064\u3044\u3066<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u904e\u53bb\u30d6\u30ed\u30b0\u3067\u4f55\u5ea6\u304b\u3054\u8aac\u660e\u6e08\u307f\u3067\u3059\u304c\u3088\u308a\u7c21\u5358\u306b\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"633\" height=\"470\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/2f440b5c78de619eef9884b1b4cdb18e.png\" alt=\"3\u9818\u57df\u306b\u5206\u985e\uff1a\uff08\u30a2\uff09\u5927\u8178\u83cc\u5185\u3067\u306e\u30d9\u30af\u30bf\u30fc\u306e\u8907\u88fd\u30fb\u7dad\u6301\u306b\u95a2\u308f\u308b\u9818\u57df\uff08\u30a4\uff09\u76ee\u7684\u907a\u4f1d\u5b50\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u767a\u73fe\u306b\u95a2\u308f\u308b\u9818\u57df\uff08\u30a6\uff09\u305d\u306e\u4ed6\u5927\u8178\u83cc\u4ee5\u5916\u306e\u751f\u7269\u5185\u3067\u306e\u6a5f\u80fd\uff08\u9078\u5225\u30fb\u30b2\u30ce\u30e0\u3078\u306e\u7d44\u307f\u8fbc\u307f\u306a\u3069\uff09\u306b\u95a2\u308f\u308b\u9818\u57df\" class=\"wp-image-21413\" style=\"width:526px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/2f440b5c78de619eef9884b1b4cdb18e.png 633w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/2f440b5c78de619eef9884b1b4cdb18e-300x223.png 300w\" sizes=\"auto, (max-width: 633px) 100vw, 633px\" \/><figcaption class=\"wp-element-caption\">3\u9818\u57df\u306b\u5206\u985e\uff1a\uff08\u30a2\uff09\u5927\u8178\u83cc\u5185\u3067\u306e\u30d9\u30af\u30bf\u30fc\u306e\u8907\u88fd\u30fb\u7dad\u6301\u306b\u95a2\u308f\u308b\u9818\u57df\uff08\u30a4\uff09\u76ee\u7684\u907a\u4f1d\u5b50\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u767a\u73fe\u306b\u95a2\u308f\u308b\u9818\u57df\uff08\u30a6\uff09\u305d\u306e\u4ed6\u5927\u8178\u83cc\u4ee5\u5916\u306e\u751f\u7269\u5185\u3067\u306e\u6a5f\u80fd\uff08\u9078\u5225\u30fb\u30b2\u30ce\u30e0\u3078\u306e\u7d44\u307f\u8fbc\u307f\u306a\u3069\uff09\u306b\u95a2\u308f\u308b\u9818\u57df<\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<p class=\"wp-block-paragraph\" style=\"font-size:13px\"><strong>\u2460\uff5e\u246c\u306e\u8aac\u660e\uff1a<\/strong><br>\u2460\u5927\u8178\u83cc\u5185\u3067\u6a5f\u80fd\u3059\u308borigin<br>\u2461\u5927\u8178\u83cc\u5185\u3067\u6a5f\u80fd\u3059\u308b\u6297\u751f\u7269\u8cea\u8010\u6027\u907a\u4f1d\u5b50<br>\u2462\u76ee\u7684\u907a\u4f1d\u5b50\u767a\u73fe\u7528\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc<br>\u2463\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8<br>\u2464\u878d\u5408\u30bf\u30b0\u914d\u5217\uff08\u3053\u306e\u4f8b\u306fN\u672b\u7aef\u30bf\u30b0 + \u30d7\u30ed\u30c6\u30a2\u30fc\u30bc\u5207\u65ad\u914d\u5217\uff09<br>\u2465\u30dd\u30eaA\u4ed8\u52a0\u30b7\u30b0\u30ca\u30eb<br>\u2466\u30b7\u30fc\u30b1\u30f3\u30b9\u7528\u30d7\u30e9\u30a4\u30de\u30fc\u306e\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u30b5\u30a4\u30c8<br>\u2467\u5927\u8178\u83cc\u4ee5\u5916\u306e\u5bbf\u4e3b\u7528\u9078\u629e\u30de\u30fc\u30ab\u30fc\uff08\u4e3b\u306b\u6297\u751f\u7269\u8cea\u8010\u6027\u907a\u4f1d\u5b50\uff09<br>\u2468\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\uff08\u2467\u7528\uff09<br>\u2469\u30dd\u30eaA\u4ed8\u52a0\u30b7\u30b0\u30ca\u30eb\uff08\u2467\u7528\uff09<br>\u246a\u5927\u8178\u83cc\u7528\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\uff08\u2467\u7528\uff09<br>\u246b\u6a5f\u80fd\u4e0a\u4e0d\u8981\u306a\u914d\u5217\uff08f1 ori\uff09<br>\u246c\u767a\u73fe\u8abf\u7bc0\u30a8\u30ec\u30e1\u30f3\u30c8<\/p>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4f8b1-\u4e00\u822c\u7684\u306a\u5927\u8178\u83cc\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc-n\u672b\u7aef\u30bf\u30b0\u4ed8\u304d\">\u4f8b1\uff1a\u4e00\u822c\u7684\u306a\u5927\u8178\u83cc\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc\uff08N\u672b\u7aef\u30bf\u30b0\u4ed8\u304d\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u76ee\u7684\u907a\u4f1d\u5b50\uff08GOI\uff09\u3092\u5927\u8178\u83cc\u3067\u5927\u91cf\u767a\u73fe\u3055\u305b\u308b\u305f\u3081\u306b\u3053\u306e\u30d9\u30af\u30bf\u30fc\u3092\u5165\u624b\u3057\u3001\u30de\u30c3\u30d7\u3068\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u898b\u3066\u4f7f\u3044\u65b9\u3092\u8003\u3048\u3066\u3044\u308b\u3068\u3044\u3046\u72b6\u6cc1\u3092\u60f3\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\u30de\u30c3\u30d7\u306f\u4e0b\u8a18\u3067\u3059\u304c\u3001\u65e2\u306b\uff08\u30a2\uff09\u30fb\uff08\u30a4\uff09\u306e\u9818\u57df\u306b\u5206\u985e\u6e08\u307f\u3067\u3059\uff08\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306f\u5927\u8178\u83cc\u4ee5\u5916\u306e\u5bbf\u4e3b\u3067\u306f\u4f7f\u3044\u307e\u305b\u3093\u306e\u3067\uff08\u30a6\uff09\u306e\u9818\u57df\u306f\u3042\u308a\u307e\u305b\u3093\uff09\u3002\u307e\u305f\u3001\u30a8\u30ec\u30e1\u30f3\u30c8\u306e\u4e00\u90e8\u306b\u30ca\u30f3\u30d0\u30fc\u3092\u4ed8\u3051\u307e\u3057\u305f\u3002\u6570\u5b57\u306f\u30a8\u30ec\u30e1\u30f3\u30c8\u8aac\u660e\u7528\u306e\u56f3\u3068\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002\u3067\u304d\u308b\u3060\u3051\u81ea\u529b\u3067\u7406\u89e3\u3092\u6df1\u3081\u3089\u308c\u308b\u306e\u306f\u3044\u3044\u3053\u3068\u3067\u3059\u304c\u3001\u4f55\u304b\u308f\u304b\u3089\u306a\u3044\u3053\u3068\u306a\u3069\u3042\u308c\u3070\u5f53\u793e\u306e\u88fd\u54c1\u3067\u3059\u306e\u3067\u5f53\u793e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"612\" height=\"507\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/f3e73484135765705244bfdcac85b457.png\" alt=\"\" class=\"wp-image-21415\" style=\"width:518px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/f3e73484135765705244bfdcac85b457.png 612w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/f3e73484135765705244bfdcac85b457-300x249.png 300w\" sizes=\"auto, (max-width: 612px) 100vw, 612px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b\">\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\uff08\u30a2\uff09\u306b\u201dAmpicillinR\u201d\u304c\u3042\u308b\u306e\u3067\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304c\u4f7f\u3048\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u3061\u306a\u307f\u306b\uff08\u30a2\uff09\u306b\u3042\u308b\u201drop\u201d\u306forigin\uff08pBR322 ori\uff09\u306e\u5236\u5fa1\u56e0\u5b50\u3067\u3001origin\u306e\u4e00\u90e8\u3060\u3068\u8003\u3048\u3066\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002\u307e\u305f\u3001rop\u304c\u5b58\u5728\u3057\u3066\u3044\u3066\u3082\u30de\u30c3\u30d7\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u306a\u3044\u30b1\u30fc\u30b9\u304c\u591a\u3044\u3088\u3046\u3067\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b-\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b\">\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b\uff1f\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u2463\u306b\u3042\u308a\u307e\u3059\u3002\u5236\u9650\u9175\u7d20\u30b5\u30a4\u30c8\u306f\u4e26\u3093\u3067\u3044\u307e\u305b\u3093\u304c\u3001\u5207\u308c\u76ee\u304c\u5165\u3063\u3066\u3044\u308b\u306e\u3067\u308f\u304b\u308a\u3084\u3059\u3044\u3068\u601d\u3044\u307e\u3059\uff08\u4e0b\u56f3\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"369\" height=\"240\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/45e3045e0ebf599fe952f7b8d9c5342c.png\" alt=\"\" class=\"wp-image-21418\" style=\"width:409px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/45e3045e0ebf599fe952f7b8d9c5342c.png 369w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/45e3045e0ebf599fe952f7b8d9c5342c-300x195.png 300w\" sizes=\"auto, (max-width: 369px) 100vw, 369px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u5f53\u793e\u72ec\u81ea\u306eDirectional TOPO\u2122\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30d9\u30af\u30bf\u30fc\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3001\u3053\u306e\u4f4d\u7f6e\u3067\u4e88\u3081\u5207\u65ad\u30fb\u7dda\u72b6\u5316\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u5236\u9650\u9175\u7d20\u3067\u5207\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u3053\u306bPCR\u3067\u5897\u3084\u3057\u305fGOI\u3092\u30e9\u30a4\u30b2\u30fc\u30b7\u30e7\u30f3\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u88fd\u54c1\u306e\u8a73\u3057\u3044\u8aac\u660e\u306f\u63a7\u3048\u307e\u3059\u304c\u3001\u3082\u3057\u3054\u8208\u5473\u304c\u3042\u308c\u3070\u88fd\u54c1\u60c5\u5831\uff08\u88fd\u54c1\u756a\u53f7\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/K15101?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">K15101<\/a>\uff09\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u30b7\u30ea\u30fc\u30ba<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-bid-ts-1\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7b2c1\u56de<\/a>\u306e\u30e1\u30e23\u3067\u5c11\u3057\u3060\u3051\u8aac\u660e\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u3088\u308d\u3057\u3051\u308c\u3070\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u306a\u304a\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306b\u3088\u3063\u3066\u306f\u4f7f\u7528\u3059\u308bPCR\u9175\u7d20\u306e\u7a2e\u985e\u304c\u9650\u5b9a\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002Directional TOPO\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30d9\u30af\u30bf\u30fc\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306e\u5834\u5408\u306f\u3044\u308f\u3086\u308b\u30cf\u30a4\u30d5\u30a3\u30c7\u30ea\u30c6\u30a3\u30fcPCR\u9175\u7d20\u3092\u4f7f\u7528\u3057\u3066PCR\u3092\u884c\u3046\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u3064\u307e\u308a\u633f\u5165\u3059\u308b2\u672c\u9396DNA\u65ad\u7247\u306e\u672b\u7aef\u304c\u5e73\u6ed1\u3067\u3042\u308b\u3053\u3068\u304c\u5fc5\u9808\u3067\u30013\u2019A\u7a81\u51fa\u304c\u4ed8\u304fTaq DNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u306f\u5411\u304d\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30bf\u30b0\u914d\u5217\u3068goi\u306e\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u305f\u3081\u306b\u306f\u3069\u3046\u3057\u305f\u3089\u3044\u3044\u306e\u304b\">\u30bf\u30b0\u914d\u5217\u3068GOI\u306e\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u305f\u3081\u306b\u306f\u3069\u3046\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306e\u4e0a\u6d41\uff08T7\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u4e0b\u6d41\u30fb\u77e2\u5370\u306e\u5148\u306e\u65b9\uff09\u306bRBS + ATG + 6xHis + V5 epitope + TEV\u3068\u3044\u3046\u30a8\u30ec\u30e1\u30f3\u30c8\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u7ffb\u8a33\u306fRBS\uff08\u30ea\u30dc\u30bd\u30fc\u30e0\u30d0\u30a4\u30f3\u30c7\u30a3\u30f3\u30b0\u30b5\u30a4\u30c8\u3001\u5225\u540dSD\u914d\u5217\uff09\u306e\u5f8c\u306eATG\u304b\u3089\u59cb\u307e\u308a\u307e\u3059\u3002\u3053\u306e\u8aad\u307f\u67a0\u3068GOI\u306e\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4e88\u3081\u5207\u308c\u76ee\u304c\u5165\u3063\u305f\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u306f\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306bGOI\u306e\u5168\u9577\u3092\u5165\u308c\u308c\u3070\u554f\u984c\u306a\u3044\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u3002\u3064\u307e\u308a\u3001ATG\uff5e\u30b9\u30c8\u30c3\u30d7\u30b3\u30c9\u30f3\u307e\u3067\u306eORF\u5168\u9577\u3092\u305d\u306e\u307e\u307e\u5165\u308c\u308b\u3053\u3068\u304c\u591a\u3044\u3067\u3059\uff08C\u672b\u7aef\u30bf\u30b0\u914d\u5217\u3068\u878d\u5408\u3055\u305b\u308b\u5834\u5408\u306f\u30b9\u30c8\u30c3\u30d7\u30b3\u30c9\u30f3\u3092\u9664\u53bb\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001Directional TOPO\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u306f\u4f8b\u5916\u3067\u3001ATG\u306e\u524d\u306bCACC\u3068\u3044\u3046\u914d\u5217\u3092\u4ed8\u52a0\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u306e\u3067\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\uff08\u8a73\u3057\u304f\u306f\u88fd\u54c1\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\uff09\u3002\u306a\u304a\u3001GOI\u306e\u6700\u521d\u306eATG\u3092\u6b8b\u3059\u3068\u3053\u3053\u304b\u3089\u7ffb\u8a33\u304c\u59cb\u307e\u308b\u53ef\u80fd\u6027\u3092\u5426\u5b9a\u3067\u304d\u306a\u3044\u305f\u3081\u3001\u7279\u306b\u7406\u7531\u304c\u7121\u3051\u308c\u3070\u6700\u521d\u306eATG\u3082\u7701\u304f\u65b9\u304c\u30d9\u30bf\u30fc\u3060\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b\">\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u3069\u306e\u3088\u3046\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3092\u884c\u3046\u306e\u304b\u306b\u3064\u3044\u3066\u3082\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u304b\u3089\u8aad\u307f\u53d6\u308c\u307e\u3059\u3002\u307e\u305a\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306e\u4e0a\u6d41\u306bT7 promoter\u304c\u3042\u308a\u3001\u4e0b\u6d41\u306bT7 terminator\u304c\u3042\u308b\u306e\u3067\u3001\u3044\u308f\u3086\u308bpET\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u5927\u8178\u83cc\u767a\u73fe\u7cfb\u3067\u4f7f\u7528\u3067\u304d\u308b\u30d9\u30af\u30bf\u30fc\u3060\u3068\u3044\u3046\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001T7 RNA\u30dd\u30ea\u30e1\u30e9\u30fc\u30bc\u3092\u8a98\u5c0e\u767a\u73fe\u3067\u304d\u308b\u3088\u3046\u306b\u6539\u5909\u3055\u308c\u305fBL21 (DE3)\u306a\u3069\u306e\u5927\u8178\u83cc\u3092\u7528\u3044\u3001IPTG\u3092\u4f7f\u3063\u3066\u8a98\u5c0e\u767a\u73fe\u3059\u308b\u305f\u3081\u306e\u30d9\u30af\u30bf\u30fc\u3067\u3042\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u246c\u2019\u304b\u3089\u767a\u73fe\u3059\u308blacI\u30bf\u30f3\u30d1\u30af\u8cea\uff08\u30e9\u30c3\u30af\u30ea\u30d7\u30ec\u30c3\u30b5\u30fc\uff09\u304c\u246c\u306elacO\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u7d50\u5408\u3057\u3066T7\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304b\u3089\u306eGOI\u306e\u8ee2\u5199\uff08mRNA\u5408\u6210\uff09\u3092\u963b\u5bb3\u3059\u308b\u304c\u3001IPTG\u3092\u6dfb\u52a0\u3059\u308b\u3068\u30e9\u30c3\u30af\u30ea\u30d7\u30ec\u30c3\u30b5\u30fc\u304clacO\u30a8\u30ec\u30e1\u30f3\u30c8\u304b\u3089\u5916\u308c\u3066mRNA\u5408\u6210\u304c\u958b\u59cb\u3055\u308c\u308b\u3068\u3044\u3046\u3057\u304f\u307f\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u306a\u304a\u3001BL21(DE3)\u306a\u3069\u306e\u5927\u8178\u83cc\u5185\u3067\u306fT7 promoter\u304b\u3089\u306e\u8ee2\u5199\u306b\u5fc5\u9808\u306eT7 RNA polymerase\u304c\u5408\u6210\u3055\u308c\u307e\u3059\u304c\u3001\u3053\u308c\u3082\u540c\u3058\u3057\u304f\u307f\u3067IPTG\u306b\u3088\u308a\u8a98\u5c0e\u3055\u308c\u307e\u3059\u3002\u3088\u3063\u3066\u3001lacI\u3001lacO\u30a8\u30ec\u30e1\u30f3\u30c8\u3092\u6301\u305f\u306a\u3044\u30d9\u30af\u30bf\u30fc\u3082\u3042\u308a\u307e\u3059\u304cIPTG\u306b\u3088\u308b\u767a\u73fe\u8a98\u5c0e\u306f\u8d77\u3053\u308a\u3001\u6a5f\u80fd\u7684\u306b\u5927\u304d\u306a\u554f\u984c\u306f\u306a\u3044\u3088\u3046\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4f8b2-\u4e00\u822c\u7684\u306a\u5927\u8178\u83cc\u7528\u767a\u73fe\u30d9\u30af\u30bf\u30fc-n\u672b\u7aef\u30bf\u30b0\u306a\u3057-c\u672b\u7aef\u30bf\u30b0\u4ed8\u304d\">\u4f8b2\uff1a\u4e00\u822c\u7684\u306a\u5927\u8178\u83cc\u7528\u767a\u73fe\u30d9\u30af\u30bf\u30fc\uff08N\u672b\u7aef\u30bf\u30b0\u306a\u3057\u3001C\u672b\u7aef\u30bf\u30b0\u4ed8\u304d\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5148\u7a0b\u3068\u540c\u3058pET\u30b7\u30b9\u30c6\u30e0\u3092\u7528\u3044\u305f\u5927\u8178\u83cc\u767a\u73fe\u7cfb\u7528\u30d9\u30af\u30bf\u30fc\u3067\u3059\u3002\u5927\u304d\u306a\u9055\u3044\u306fN\u672b\u30bf\u30b0\u306e\u4ee3\u308f\u308a\u306bC\u672b\u30bf\u30b0\uff086xHis\uff09\u3092\u4ed8\u3051\u3089\u308c\u308b\u70b9\u3068\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u304c\u7570\u306a\u308b\u70b9\u3067\u3059\u3002\u4f8b1\u3068\u540c\u69d8\uff08\u30a2\uff09\u3001\uff08\u30a4\uff09\u306e2\u9818\u57df\u306b\u5206\u985e\u6e08\u307f\u3067\u3059\u3002\u5404\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u4ed8\u3051\u305f\u756a\u53f7\u306b\u3064\u3044\u3066\u3082\u540c\u69d8\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"404\" height=\"500\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/d7ead3eadf6753e8250f605f8defdb70.png\" alt=\"\" class=\"wp-image-21419\" style=\"width:377px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/d7ead3eadf6753e8250f605f8defdb70.png 404w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/d7ead3eadf6753e8250f605f8defdb70-242x300.png 242w\" sizes=\"auto, (max-width: 404px) 100vw, 404px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b-0\">\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\uff08\u30a2\uff09\u306b\u201dAmpicillinR\u201d\u304c\u3042\u308b\u306e\u3067\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304c\u4f7f\u3048\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b-\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b-0\">\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b\uff1f\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u2463\u306b3\u3064\u3060\u3051\u3067\u3059\u304c\u5236\u9650\u9175\u7d20\u30b5\u30a4\u30c8\u304c\u4e26\u3093\u3067\u3044\u307e\u3059\uff08<em>Xba<\/em> I\u3001<em>Nsi<\/em> I\u3001<em>Xho<\/em> I\uff09\u3002\u3053\u3053\u306bGOI\u3092\u633f\u5165\u3057\u307e\u3059\u3002\u3053\u306e\u4f4d\u7f6e\u3067\u30d9\u30af\u30bf\u30fc\u3092\u5207\u65ad\u30fb\u7dda\u72b6\u5316\u3057\u3001DNA\u30ea\u30ac\u30fc\u30bc\u3092\u4f7f\u3063\u3066GOI\u3092\u30e9\u30a4\u30b2\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u3068\u3044\u3046\u306e\u304c\u6700\u3082\u4e00\u822c\u7684\u306a\u65b9\u6cd5\u3067\u3059\u3002\u3042\u308b\u3044\u306fGibson\u7b49\u306e\u30b7\u30fc\u30e0\u30ec\u30b9\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3067\u884c\u3046\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u306a\u304a\u3001\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u3001\u6ce8\u610f\u3059\u308b\u70b9\u306f\u3053\u306e\u5f8c\u306b\u793a\u30592\u70b9\u3067\u3059\u3002\u307e\u305f\u3001\u305d\u308c\u3089\u3092\u8003\u616e\u3059\u308b\u306b\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u5468\u8fba\u306e\u5869\u57fa\u914d\u5217\u60c5\u5831\u304c\u5fc5\u9808\u3067\u3059\u30026X His\u30bf\u30b0\u306e\u8aad\u307f\u67a0\u3092\u8d64\u7dda\u3067\u66f8\u304d\u8fbc\u307f\u3001\u7ffb\u8a33\u7d42\u6b62\u30b3\u30c9\u30f3\uff08Stop\uff09\u3092\u660e\u793a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"668\" height=\"259\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/d86a663121e9fad292533655a4ab7909.png\" alt=\"\" class=\"wp-image-21420\" style=\"width:787px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/d86a663121e9fad292533655a4ab7909.png 668w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/d86a663121e9fad292533655a4ab7909-300x116.png 300w\" sizes=\"auto, (max-width: 668px) 100vw, 668px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-rbs\u304b\u3089atg\u307e\u3067\u306e\u8ddd\u96e2\u304c5-13\u5869\u57fa\u306b\u306a\u308b\u3088\u3046\u306b\u3059\u308b\">RBS\u304b\u3089ATG\u307e\u3067\u306e\u8ddd\u96e2\u304c5\uff5e13\u5869\u57fa\u306b\u306a\u308b\u3088\u3046\u306b\u3059\u308b<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u52b9\u7387\u7684\u306a\u7ffb\u8a33\u306b\u306f\u3001RBS\u304b\u3089\u7ffb\u8a33\u958b\u59cb\u30b3\u30c9\u30f3\uff08ATG\uff09\u307e\u3067\u306e\u8ddd\u96e2\u304c\u91cd\u8981\u3067\u3059\u3002\u6240\u8aac\u3042\u308a\u307e\u3059\u304c5\uff5e13\u5869\u57fa\u304c\u9069\u5207\u3060\u3068\u8a00\u308f\u308c\u3066\u3044\u307e\u3059\u3002\u3067\u304d\u308b\u3060\u3051\u8ddd\u96e2\u304c5\uff5e13\u5869\u57fa\u306b\u306a\u308b\u3088\u3046\u306bGOI\u3092\u633f\u5165\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u3001<em>Xba<\/em> I\u30b5\u30a4\u30c8\uff08TCTAGA\uff09\u3092\u4f7f\u3044\u3001GOI\u914d\u5217\u3092\u30ea\u30f3\u30ab\u30fc\u7121\u3057\u3067\u76f4\u7d50\u3059\u308b\u3068RBS\u3068ATG\u306e\u8ddd\u96e2\u306f6\u5869\u57fa\uff08\u9593\u306b6\u5869\u57fa\u5165\u308b\uff09\u3067\u3059\u3002\u306a\u304a\u3001<em>Nsi<\/em> I\u30b5\u30a4\u30c8\uff08ATGCAT\uff09\u3092\u5229\u7528\u3055\u308c\u308b\u5834\u5408\u306f\u5c11\u3057\u7279\u6b8a\u306a\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002<em>Nsi<\/em> I\u30b5\u30a4\u30c8\u4e2d\u306bATG\u304c\u3042\u308a\u3001\u7ffb\u8a33\u958b\u59cb\u30b3\u30c9\u30f3\u3068\u3057\u3066\u6a5f\u80fd\u3059\u308b\u305f\u3081\u3067\u3059\u3002<em>Nsi<\/em> I\u30b5\u30a4\u30c8\u306e\u4e0b\u6d41\u306bGOI\u914d\u5217\u3001\u3042\u308b\u3044\u306fGOI\u914d\u5217\u304b\u3089ATG\u3092\u9664\u53bb\u3057\u305f\u914d\u5217\u3092\u76f4\u63a5\u3064\u306a\u3050\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u304c\u3001<em>Nsi<\/em> I\u30b5\u30a4\u30c8\u4e2d\u306eATG\u304b\u3089\u7ffb\u8a33\u304c\u59cb\u307e\u308b\u305f\u3081\u3001ATGCAT\u304c\u7ffb\u8a33\u3055\u308c\u305f\u30e1\u30c1\u30aa\u30cb\u30f3\u3000\u30d2\u30b9\u30c1\u30b8\u30f3\u304c\u982d\u306b\u3064\u304d\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3082RBS\u3068ATG\u306e\u9593\u306e\u5869\u57fa\u6570\u306f6\u3067\u3059\u304c\u3001\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u5185\u90e8\u914d\u5217\u306b<em>Xba<\/em> I\u30b5\u30a4\u30c8\u304c\u306a\u3051\u308c\u3070<em>Xba<\/em> I\u30b5\u30a4\u30c8\u3092\u5229\u7528\u3057\u305f\u65b9\u304c\u3088\u3055\u305d\u3046\u3067\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-c\u672b\u30bf\u30b0-6xhis-\u3068\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b-\u30b9\u30c8\u30c3\u30d7\u30b3\u30c9\u30f3\u3092\u9664\u53bb\u3059\u308b\">C\u672b\u30bf\u30b0\uff086xHis\uff09\u3068\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u30fb\u30b9\u30c8\u30c3\u30d7\u30b3\u30c9\u30f3\u3092\u9664\u53bb\u3059\u308b<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f8b\u3048\u3070<em>Xba<\/em> I\u30b5\u30a4\u30c8\u3068<em>Xho<\/em> I\u30b5\u30a4\u30c8\uff08CTCGAG\uff09\u306e\u9593\u306bGOI\u3092\u633f\u5165\u3059\u308b\u5834\u5408\u306b\u3064\u3044\u3066\u3067\u3059\u3002<em>Xho<\/em> I\u914d\u5217\u3092C\u672b\u7aef\u306e6xHis\u30bf\u30b0\u306b\u5408\u308f\u305b\u305f\u8aad\u307f\u67a0\u3067\u533a\u5207\u308b\u3068CTC GAG\u3067\u3059\u306e\u3067\u3001\u30b9\u30c8\u30c3\u30d7\u30b3\u30c9\u30f3\u3092\u9664\u53bb\u3057\u305fGOI\u3092\u30ea\u30f3\u30ab\u30fc\u7121\u3057\u3067<em>Xho<\/em> I\u30b5\u30a4\u30c8\u306b\u76f4\u7d50\u3059\u308b\u3068C\u672b\u30bf\u30b0\uff086xHis\u30bf\u30b0\uff09\u3068\u8aad\u307f\u67a0\u304c\u5408\u3044\u307e\u3059\u3002\u3082\u3057C\u672b\u30bf\u30b0\u3092\u878d\u5408\u3055\u305b\u305f\u304f\u306a\u3044\u5834\u5408\u306f\u907a\u4f1d\u5b50\u306e\u30b9\u30c8\u30c3\u30d7\u30b3\u30c9\u30f3\u3092\u6b8b\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u306a\u304a\u30012\u304b\u6240\u3067\u5207\u65ad\u3059\u308b\u5834\u5408\u3001\u4e21\u30b5\u30a4\u30c8\u306e\u8ddd\u96e2\u304c\u6700\u4f4e2\u5869\u57fa\u7a0b\u96e2\u308c\u3066\u3044\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306e\u5834\u5408\u306f<em>Xba<\/em> I\u3068<em>Xho<\/em> I\u306e\u8ddd\u96e2\u304c6\u5869\u57fa\u4ee5\u4e0a\u6163\u308c\u3066\u3044\u308b\u306e\u3067\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b-0\">\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f8b1\u3068\u540c\u3058pET\u7cfb\u5927\u8178\u83cc\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc\u3067\u3059\u306e\u3067\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u65b9\u6cd5\u306f\u5168\u304f\u540c\u3058\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4f8b3-\u6606\u866b\u7d30\u80de\u767a\u73fe\u3067\u4f7f\u3046\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u4f5c\u6210\u7528\u30d9\u30af\u30bf\u30fc-bac-to-bac-baculovirus-expression-system\u7528\">\u4f8b3\uff1a\u6606\u866b\u7d30\u80de\u767a\u73fe\u3067\u4f7f\u3046\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u4f5c\u6210\u7528\u30d9\u30af\u30bf\u30fc\uff08Bac-to-Bac Baculovirus Expression System\u7528\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6606\u866b\u7d30\u80de\u767a\u73fe\u306b\u4f7f\u7528\u3059\u308b\u7d44\u307f\u63db\u3048\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u4f5c\u6210\u7528\u30d9\u30af\u30bf\u30fc\u3067\u3059\u3002\u7d44\u307f\u63db\u3048\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u3092\u4f5c\u6210\u3059\u308b\u65b9\u6cd5\u306f\u8907\u6570\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306f\u5f53\u793e\u306eGibco\u2122 Bac-to-Bac\u2122 Baculovirus Expression System\u7528\u3067\u3059\u3002\u6606\u866b\u7d30\u80de\u3067\u6a5f\u80fd\u3059\u308b\u30dd\u30ea\u30d8\u30c9\u30ea\u30f3\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\uff08pPH\uff09\u3068\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u30b2\u30ce\u30e0\uff08Bacmid\uff09\u3068\u306e\u7d44\u307f\u63db\u3048\u30b5\u30a4\u30c8\uff08Tn7R\u3001Tn7L\uff09\u304c\u3042\u308b\u3053\u3068\u304c\u7279\u5fb4\u3067\u3059\u3002\u306a\u304a\u3001\uff08\u30a2\uff09\u3068\uff08\u30a6\uff09\u304c\u4e8c\u304b\u6240\u305a\u3064\u3042\u308a\u8907\u96d1\u3067\u3059\u304c\u30013\u9818\u57df\u306b\u5206\u985e\u6e08\u307f\u3067\u3059\u3002\u756a\u53f7\u306f\u5148\u7a0b\u306e\u4f8b\u3068\u540c\u69d8\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"423\" height=\"518\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/78bef0b2747c7495b84e87b7f06cd117.png\" alt=\"\" class=\"wp-image-21421\" style=\"width:381px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/78bef0b2747c7495b84e87b7f06cd117.png 423w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/78bef0b2747c7495b84e87b7f06cd117-245x300.png 245w\" sizes=\"auto, (max-width: 423px) 100vw, 423px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b-1\">\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u4f7f\u7528\u3059\u308b\u6297\u751f\u7269\u8cea\u306f\u4f55\u304c\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\uff08\u30a2\uff09\u306b\u201dAmpicillin<sup>R<\/sup>\u201d\u304c\u3042\u308b\u306e\u3067\u30a2\u30f3\u30d4\u30b7\u30ea\u30f3\u304c\u4f7f\u3048\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u306a\u304a\u3001\u5b9f\u306f\u30b2\u30f3\u30bf\u30de\u30a4\u30b7\u30f3\u3082\u4f7f\u7528\u53ef\u80fd\u3067\u3059\u3002\u2461\u2019\u306e\u30b2\u30f3\u30bf\u30de\u30a4\u30b7\u30f3\u8010\u6027\u907a\u4f1d\u5b50\uff08Gentamicin<sup>R<\/sup>\uff09\u306e\u4e0a\u6d41\u306b\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u306e\u8a18\u8f09\u304c\u306a\u304f\u5206\u304b\u308a\u306b\u304f\u3044\u3067\u3059\u304c\u3001\u4f55\u3082\u8a18\u8f09\u304c\u306a\u3051\u308c\u3070\u5927\u8178\u83cc\u7528\u306e\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304c\u7701\u7565\u3055\u308c\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u975e\u5e38\u306b\u9ad8\u304f\u3001\u3053\u306e\u30d9\u30af\u30bf\u30fc\u3082\u7136\u308a\u3067\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b-\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b-1\">\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b\uff1f\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u2463\u306b\u30de\u30eb\u30c1\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\uff08MCS\uff09\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u3053\u3053\u306b\u5236\u9650\u9175\u7d20\u3068DNA\u30ea\u30ac\u30fc\u30bc\u3092\u7528\u3044\u305f\u65b9\u6cd5\u3001\u3042\u308b\u3044\u306fGibson\u7b49\u306e\u30b7\u30fc\u30e0\u30ec\u30b9\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u6cd5\u3067GOI\u3092\u633f\u5165\u53ef\u80fd\u3067\u3059\u3002\u30d9\u30af\u30bf\u30fc\u306b\u878d\u5408\u30bf\u30b0\u914d\u5217\u306f\u3042\u308a\u307e\u305b\u3093\u306e\u3067\u3001\u7279\u306b\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u5de5\u592b\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u3002MCS\u306e\u3069\u3053\u3067\u3082\u3044\u3044\u308f\u3051\u3067\u3059\u304c\u3001\u4ee5\u4e0b\u306e\u57fa\u6e96\u3067\u633f\u5165\u5834\u6240\u3092\u9078\u3070\u308c\u308b\u306e\u304c\u304a\u52e7\u3081\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>GOI\u306b\u5b58\u5728\u3057\u306a\u3044\u5236\u9650\u9175\u7d20\u3092\u9078\u629e\uff08DNA\u30ea\u30ac\u30fc\u30bc\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\uff09<\/li>\n\n\n\n<li>\u30e9\u30dc\u306b\u3042\u308b\u30fb\u5b89\u4fa1\u306a\u30fb\u591a\u304f\u306e\u30e1\u30fc\u30ab\u30fc\u304b\u3089\u8ca9\u58f2\u3055\u308c\u3066\u3044\u308b\u5236\u9650\u9175\u7d20\u3092\u9078\u629e<\/li>\n\n\n\n<li>\u3067\u304d\u308c\u3070MCS\u306e\u4e0a\u6d41\u3068\u4e0b\u6d41\u306e\u4e8c\u30ab\u6240\uff08\u3067\u304d\u308b\u3060\u3051\u4f59\u5206\u306a\u914d\u5217\u3092\u6b8b\u3055\u306a\u3044\u65b9\u304c\u4f59\u8a08\u306a\u53ef\u80fd\u6027\u3092\u8003\u3048\u308b\u5fc5\u8981\u304c\u306a\u3044\u306e\u3067\u5b89\u5fc3\u3068\u3044\u3046\u7a0b\u5ea6\u306e\u7406\u7531\uff09<\/li>\n<\/ul>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b-1\">\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u793e\u306eBac-to-Bac\u2122 Baculovirus Expression System\u7528\u30d9\u30af\u30bf\u30fc\u3067\u3059\u306e\u3067\u4ee5\u4e0b\u306e\u6d41\u308c\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>pFastBac1\u306e\u3088\u3046\u306a\u5c02\u7528\u30d9\u30af\u30bf\u30fc\u306bGOI\u3092\u7d44\u307f\u8fbc\u3080<\/li>\n\n\n\n<li>\u5c02\u7528\u5927\u8178\u83cc\uff08DH10Bac\uff09\u306b\u4e0a\u8a18\u3092\u5c0e\u5165\u3057\u3001\u5927\u8178\u83cc\u5185\u90e8\u3067GOI\u3092\u7d44\u307f\u8fbc\u3093\u3060\u7d44\u307f\u63db\u3048Bacmid\u3092\u8abf\u88fd\u3059\u308b<\/li>\n\n\n\n<li>\u7cbe\u88fd\u7d44\u307f\u63db\u3048Bamid\u3092\u6606\u866b\u7d30\u80de\u3078\u30c8\u30e9\u30f3\u30b9\u30d5\u30a7\u30af\u30b7\u30e7\u30f3\u3067\u5c0e\u5165\u3057\u3001\u7d44\u307f\u63db\u3048\u30d0\u30ad\u30e5\u30ed\u30a6\u30a4\u30eb\u30b9\u3092\u4f5c\u6210<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3089\u306b\u8a73\u3057\u304f\u304a\u77e5\u308a\u306b\u306a\u308a\u305f\u3044\u65b9\u306f\u88fd\u54c1\u30de\u30cb\u30e5\u30a2\u30eb\uff08\u88fd\u54c1\u756a\u53f7\uff1a<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10359016?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">10359016<\/a>\uff09\u3092\u3054\u78ba\u8a8d\u3044\u305f\u3060\u304f\u304b\u3001\u5f53\u793e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u306b\u304a\u554f\u5408\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4f8b4-\u9175\u6bcdpichia\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc\">\u4f8b4\uff1a\u9175\u6bcdPichia\u767a\u73fe\u7528\u30d9\u30af\u30bf\u30fc<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306f<em>Pichia pastoris<\/em>\u3068\u3044\u3046\u9175\u6bcd\u3092\u7528\u3044\u305f\u767a\u73fe\u7cfb\u7528\u30d9\u30af\u30bf\u30fc\u306e\u4f8b\u3067\u3059\u3002<em>Pichia pastoris<\/em>\u306f\u771f\u6838\u751f\u7269\u3067\u3059\u304c\u6bd4\u8f03\u7684\u5b89\u4fa1\u3067\u304b\u3064\u9ad8\u767a\u73fe\u3092\u671f\u5f85\u3067\u304d\u308b\u305f\u3081\u3001\u5927\u8178\u83cc\u767a\u73fe\u7cfb\u3067\u53ef\u6eb6\u6027\u767a\u73fe\u304c\u53f6\u308f\u306a\u304b\u3063\u305f\u5834\u5408\u306a\u3069\u306b\u8a66\u3055\u308c\u308b\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u3002\u307e\u305f\u3001\u5927\u8178\u83cc\u3068\u9055\u3044\u5206\u6ccc\u767a\u73fe\u304c\u5f97\u610f\u3067\u3001\u4f8b\u3048\u3070\u30b5\u30a4\u30c8\u30ab\u30a4\u30f3\u306a\u3069\u306e\u5927\u91cf\u8abf\u88fd\u3067\u5b9f\u7e3e\u304c\u3042\u308a\u307e\u3059\u3002\u3061\u306a\u307f\u306b\u3053\u306e\u30d9\u30af\u30bf\u30fc\u306f\u5206\u6ccc\u767a\u73fe\u7528\u3067\u3059\u3002\u306a\u304a\u3001\u2460\uff5e\u2462\u306e\u9818\u57df\u306b\u5206\u985e\u6e08\u307f\u3067\u3059\u3002\u308f\u304b\u308a\u306b\u304f\u3044\u3067\u3059\u304c5\u2019 AOX1\u304cGOI\u767a\u73fe\u7528\u306e\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u3067\u3001\u305d\u306e\u4e0b\u6d41\u306e\u03b1-factor\u304c\u5206\u6ccc\u30b7\u30b0\u30ca\u30eb\u3067\u3059\u3002\u756a\u53f7\u306f\u30a8\u30ec\u30e1\u30f3\u30c8\u8aac\u660e\u306e\u56f3\u3068\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"612\" height=\"508\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/01291942f22dc52f7137d93d31bc667e.png\" alt=\"\" class=\"wp-image-21422\" style=\"width:516px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/01291942f22dc52f7137d93d31bc667e.png 612w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/01291942f22dc52f7137d93d31bc667e-300x249.png 300w\" sizes=\"auto, (max-width: 612px) 100vw, 612px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\uff08\u30a2\uff09\u306b\u6297\u751f\u7269\u8cea\u8010\u6027\u907a\u4f1d\u5b50\u304c\u898b\u5f53\u305f\u308a\u307e\u305b\u3093\u3002\u305d\u306e\u5834\u5408\u306f\u7126\u3089\u305a\u306b\uff08\u30a6\uff09\u3092\u898b\u3066\u304f\u3060\u3055\u3044\u3002\u9175\u6bcd\u7528\u306e\u8010\u6027\u907a\u4f1d\u5b50Zeocin<sup>R<\/sup>\u306e\uff08\u77e2\u5370\u306e\u982d\u304c\u7701\u7565\uff1f\u3055\u308c\u3066\u3044\u3066\u308f\u304b\u308a\u306b\u304f\u3044\u3067\u3059\u304c\uff09\u4e0a\u6d41\u306b\u5927\u8178\u83cc\u7528\u306eEM7\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u304c\u3042\u308b\u3053\u3068\u304b\u3089\u3001\u5927\u8178\u83cc\u306e\u9078\u5225\u306b\u3082Zeocin\u3092\u4f7f\u7528\u3067\u304d\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u672c\u30d9\u30af\u30bf\u30fc\u306e\u3088\u3046\u306b\u3001\u30d9\u30af\u30bf\u30fc\u30b5\u30a4\u30ba\u3092\u5c0f\u3055\u304f\u3059\u308b\u305f\u3081\u306b\u5927\u8178\u83cc\u4ee5\u5916\u306e\u30db\u30b9\u30c8\u7528\u9078\u629e\u30de\u30fc\u30ab\u30fc\u3068\u5927\u8178\u83cc\u7528\u9078\u629e\u30de\u30fc\u30ab\u30fc\u3092\u5171\u7528\u3057\u3066\u3044\u308b\u30b1\u30fc\u30b9\u306f\u3057\u3070\u3057\u3070\u898b\u53d7\u3051\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b-\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b-2\">\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\u306f\u3069\u3053\u304b\uff1f\u3069\u306e\u3088\u3046\u306b\u907a\u4f1d\u5b50\u3092\u633f\u5165\u3057\u305f\u3089\u3044\u3044\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u2463\u306b\u30de\u30eb\u30c1\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30b5\u30a4\u30c8\uff08MCS\uff09\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u3053\u3053\u306b\u5236\u9650\u9175\u7d20\u3068DNA\u30ea\u30ac\u30fc\u30bc\u3092\u7528\u3044\u305f\u65b9\u6cd5\u3001\u3042\u308b\u3044\u306fGibson\u7b49\u30b7\u30fc\u30e0\u30ec\u30b9\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u6cd5\u3067GOI\u3092\u633f\u5165\u53ef\u80fd\u3067\u3059\u3002\u6ce8\u610f\u304c\u5fc5\u8981\u306a\u306e\u306fGOI\u306e\u4e21\u5074\u3067\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u5fc5\u8981\u304c\u3042\u308b\u70b9\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u56f3\u3092\u53c2\u8003\u306b\u3057\u3066\u3001N\u672b\u5074\u306e\u5206\u6ccc\u7528\u30b7\u30b0\u30ca\u30eb\u30da\u30d7\u30c1\u30c9\u914d\u5217\uff08\u03b1-factor signal sequence\uff5eSte13 signal cleavage\u914d\u5217\u307e\u3067\uff09\u3068C\u672b\u5074\u306e\u878d\u5408\u30bf\u30b0\uff08c-myc epitope + polyhistidine tag\uff09\u306e\u4e21\u65b9\u3068GOI\u306e\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3082\u3061\u308d\u3093C\u672b\u7aef\u30bf\u30b0\u3092\u878d\u5408\u3055\u305b\u306a\u3044\u5834\u5408\u306fGOI\u306e\u30b9\u30c8\u30c3\u30d7\u30b3\u30c9\u30f3\u3092\u6b8b\u3057\u3001\u304b\u3064\u8aad\u307f\u67a0\u306f\u6c17\u306b\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u56f3\u306b\u306fN\u672b\u5074\u306e\u8aad\u307f\u67a0\u3092\u8d64\u7dda\u3001C\u672b\u5074\u306e\u8aad\u307f\u67a0\u3092\u9752\u7dda\u3067\u793a\u3057\u307e\u3057\u305f\u3002\u7ffb\u8a33\u306f\u03b1-factor signal sequence\u306e\u982d\u306eATG\u304b\u3089\u59cb\u307e\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center has-small-font-size wp-block-paragraph\">\u203b\u30af\u30ea\u30c3\u30af\u3057\u3066\u753b\u50cf\u3092\u62e1\u5927<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><a href=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/1622b792ca371f2fcb63fe983221c1d5.png\"><img loading=\"lazy\" decoding=\"async\" width=\"710\" height=\"796\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/1622b792ca371f2fcb63fe983221c1d5.png\" alt=\"\" class=\"wp-image-21423\" style=\"width:494px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/1622b792ca371f2fcb63fe983221c1d5.png 710w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/1622b792ca371f2fcb63fe983221c1d5-268x300.png 268w\" sizes=\"auto, (max-width: 710px) 100vw, 710px\" \/><\/a><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u306a\u304a\u3001\u3069\u3046\u3057\u3066\u3082GOI\u306eN\u672b\u7aef\u306b\u4f59\u8a08\u306a\u914d\u5217\u3092\u4ed8\u3051\u305f\u304f\u306a\u3044\u5834\u5408\u306b\u3068\u308b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u4ee5\u4e0b\u306b\u7c21\u5358\u306b\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f8b\u3048\u3070<em>EcoR<\/em> I\u30b5\u30a4\u30c8\uff08GAATTC\uff09\u306bGOI\u3092\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3059\u308b\u5834\u5408\u306fGAA TTC GOI\u914d\u5217\u3068\u306a\u308a\u3001GOI\u914d\u5217\u306eN\u672b\u306bGlu Phe\u306e2\u30a2\u30df\u30ce\u9178\u304c\u4ed8\u52a0\u3055\u308c\u307e\u3059\u3002\u3067\u304d\u308b\u3060\u3051GOI\u306eN\u672b\u306b\u4f55\u3082\u4ed8\u3051\u305f\u304f\u306a\u3044\u5834\u5408\u306e\u304a\u52e7\u3081\u306e\u65b9\u6cd5\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30d9\u30af\u30bf\u30fc\u3092Kex2 signal cleavage\u306e\u5c11\u3057\u4e0a\u6d41\u306e<em>Xho<\/em> I\u30b5\u30a4\u30c8\u3067\u5207\u65ad\uff08MCS\u306b\u3082\u4e00\u3064<em>Xho<\/em> I\u30b5\u30a4\u30c8\u304c\u3042\u308b\u70b9\u8981\u6ce8\u610f\uff09<\/li>\n\n\n\n<li>GOI\u306e5\u2019\u672b\u306bPCR\u3067<em>Xho<\/em> I\u304b\u3089Kex2 signal cleavage\u30b5\u30a4\u30c8\uff08AAA AGA\u307e\u3067\uff09\u3092\u4ed8\u52a0<\/li>\n\n\n\n<li>\u4e0a\u8a18\u3092Xho I\u3067\u5207\u65ad\u3057\u305f\u3082\u306e\u3092\u30d9\u30af\u30bf\u30fc\u306b\u30e9\u30a4\u30b2\u30fc\u30b7\u30e7\u30f3<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8a18\u306e\u65b9\u6cd5\u3067\u884c\u3046\u3068\u3001Kex2 singal cleavage\u306e\u76f4\u5f8c\u306bGOI\u304c\u633f\u5165\u3055\u308c\u3001Kex2\u306b\u3088\u308b\u30d7\u30ed\u30bb\u30b7\u30f3\u30b0\uff08\u5207\u65ad\uff09\u304c\u3046\u307e\u304f\u3044\u3051\u3070\u3001GOI\u306eN\u672b\u7aef\u306b\u4f59\u8a08\u306a\u914d\u5217\u304c\u4ed8\u304b\u306a\u3044\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b-2\">\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306f\u3069\u306e\u3088\u3046\u306b\u884c\u3046\u306e\u304b\uff1f<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30de\u30c3\u30d7\u304b\u3089\u3069\u306e\u3088\u3046\u306b\u6271\u3046\u304b\u3092\u8aad\u307f\u53d6\u308c\u307e\u3059\u304c\u3001\u5168\u304f<em>Pichia<\/em>\u767a\u73fe\u7cfb\u306b\u3064\u3044\u3066\u3054\u5b58\u3058\u306a\u3044\u5834\u5408\u306f\u304a\u624b\u6570\u3067\u3059\u304c\u30de\u30cb\u30e5\u30a2\u30eb\u3092\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u4e0d\u660e\u70b9\u3042\u308c\u3070\u5f53\u793e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u3092\u3054\u5229\u7528\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306b\u7c21\u5358\u306b\u6d41\u308c\u3092\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30d9\u30af\u30bf\u30fc\u306eMCS\u306bGOI\u3092\u30af\u30ed\u30fc\u30cb\u30f3\u30b0<\/li>\n\n\n\n<li>5\u2019AOX1\u306e\u4e00\u304b\u6240\u3067\u5236\u9650\u9175\u7d20\u5207\u65ad\u2192\u7c21\u6613\u7cbe\u88fd<\/li>\n\n\n\n<li><em>Pichia pastoris<\/em>\u306b\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u7b49\u3067\u5c0e\u5165<\/li>\n\n\n\n<li>Zocin\u3067\u9078\u5225<\/li>\n\n\n\n<li>\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\uff08\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u8a98\u5c0e\uff09<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Pichia\u30b2\u30ce\u30e0\u306eAOX1\u30b5\u30a4\u30c8\uff08\u30e1\u30bf\u30ce\u30fc\u30eb\u8cc7\u5316\u306b\u95a2\u308f\u308b\u9175\u7d20\u306e\u30d7\u30ed\u30e2\u30fc\u30bf\u30fc\u9818\u57df\uff09\u306b\u76f8\u540c\u7d44\u307f\u63db\u3048\u3067\u30d9\u30af\u30bf\u30fc\u4e38\u3054\u3068\u3092\u633f\u5165\u3057\u307e\u3059\u3002\u30d9\u30af\u30bf\u30fc\u3092\u5207\u3089\u306a\u304f\u3066\u3082\u5165\u308b\u306f\u305a\u3067\u3059\u304c\u3001\u52b9\u7387\u3092\u4e0a\u3052\u308b\u305f\u3081\u3068\u3001\u4e88\u671f\u305b\u306c\u5834\u6240\u306b\u5165\u308b\u78ba\u7387\u3092\u4e0b\u3052\u308b\u305f\u3081\u306b\u3001\u4e88\u3081\u30d9\u30af\u30bf\u30fc\u306eAOX1\u914d\u5217\u4e0a\u3067\u30ab\u30c3\u30c8\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u3066\u3044\u307e\u3059\u3002\u5f62\u8cea\u8ee2\u63db\u5f8cZeocin\u3067\u5f62\u8cea\u8ee2\u63db\u682a\u3092\u9078\u5225\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6700\u5f8c\u306b\">\u6700\u5f8c\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2\u56de\u306b\u308f\u305f\u3063\u3066\u3001\u30de\u30c3\u30d7\u304b\u3089\u30d9\u30af\u30bf\u30fc\u306e\u4f7f\u3044\u65b9\u3092\u8aad\u307f\u53d6\u308b\u65b9\u6cd5\u3092\u3054\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u5c11\u3057\u3067\u3082\u3054\u53c2\u8003\u306b\u306a\u3063\u305f\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30de\u30c3\u30d7\u3092\u898b\u308b\u3068\u3001\u624b\u5143\u306e\u30d9\u30af\u30bf\u30fc\u304c\u3069\u3093\u306a\u3082\u306e\u304b\u3060\u3051\u3067\u306a\u304f\u3001\u6271\u3044\u65b9\u3084\u5b9f\u9a13\u306e\u9032\u3081\u65b9\u3082\u8aad\u307f\u53d6\u308c\u307e\u3059\u3002\u8a00\u3044\u63db\u3048\u308b\u3068\u3001\u30de\u30c3\u30d7\u306f\u30d9\u30af\u30bf\u30fc\u3092\u7528\u3044\u305f\u5b9f\u9a13\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u3067\u3001\u30de\u30c3\u30d7\u304b\u3089\u5b9f\u9a13\u306e\u9032\u3081\u65b9\u307e\u3067\u8aad\u307f\u53d6\u308b\u5fc5\u8981\u304c\u3042\u308b\u3068\u3082\u8a00\u3048\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u8aad\u307f\u67a0\u3092\u5408\u308f\u305b\u308b\u5834\u5408\u306a\u3069\u30de\u30c3\u30d7\u4ee5\u5916\u306e\u60c5\u5831\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u3082\u3054\u7406\u89e3\u3044\u305f\u3060\u3051\u305f\u304b\u3068\u601d\u3044\u307e\u3059\u3002\u3053\u306e4\u56de\u306e\u30d6\u30ed\u30b0\u3092\u901a\u3057\u3066\u3001\u30de\u30c3\u30d7\u304b\u3089\u30d9\u30af\u30bf\u30fc\u3092\u6271\u3046\u4e0a\u3067\u306e\u6700\u4f4e\u9650\u306e\u60c5\u5831\u3092\u8aad\u307f\u53d6\u308c\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u3044\u305f\u3060\u304d\u3001\u305d\u306e\u4ed6\u5fc5\u8981\u306a\u60c5\u5831\u3092\u88fd\u54c1\u30de\u30cb\u30e5\u30a2\u30eb\u306b\u63a2\u3057\u306b\u884c\u3051\u308b\u3088\u3046\u306b\u306a\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u30e1\u30fc\u30ab\u30fc\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u3082\u4e0a\u624b\u306b\u6d3b\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001\u3054\u5229\u7528\u3044\u305f\u3060\u304f\u767a\u73fe\u7cfb\u306b\u3064\u3044\u3066\u3054\u7406\u89e3\u3044\u305f\u3060\u304f\u3053\u3068\u306f\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u3092\u3088\u308a\u8a73\u3057\u304f\u30fb\u30b9\u30de\u30fc\u30c8\u306b\u7406\u89e3\u3059\u308b\u305f\u3081\u306e\u65e9\u9053\u3067\u3059\u3002\u305d\u306e\u3042\u305f\u308a\u306b\u3064\u3044\u3066\u307e\u305f\u5225\u306e\u30d6\u30ed\u30b0\u3067\u304a\u8a71\u3067\u308c\u3070\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3054\u610f\u898b\u7b49\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u672b\u5c3e\u306e\u30d5\u30a9\u30fc\u30e0\u3067\u304a\u5831\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9f\u969b\u304a\u6301\u3061\u306e\u30d7\u30e9\u30b9\u30df\u30c9\u30d9\u30af\u30bf\u30fc\u306e\u89e3\u8aad\u30b5\u30dd\u30fc\u30c8\u3044\u305f\u3057\u307e\u3059\uff01\u3082\u3061\u308d\u3093\u5f53\u793e\u306e\u3082\u306e\u3067\u306a\u304f\u3066\u3082\u69cb\u3044\u307e\u305b\u3093\u3002\u30de\u30c3\u30d7\u3092\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u5b9b\u3066\uff08<a href=\"mailto:jptech@thermofisher.com\" target=\"_blank\" rel=\"noreferrer noopener\">jptech@<\/a><a href=\"mailto:jptech@thermofisher.com?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">thermofisher<\/a><a href=\"mailto:jptech@thermofisher.com\" target=\"_blank\" rel=\"noreferrer noopener\">.com<\/a>\uff09\u306b\u304a\u9001\u308a\u3044\u305f\u3060\u304f\u304b\u3001\u672c\u8a18\u4e8b\u306e\u4e00\u756a\u4e0b\u306b\u3042\u308b\u30d5\u30a9\u30fc\u30e0\u304b\u3089\u3054\u4f9d\u983c\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\"><\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-\u30c6\u30af\u30cb\u30ab\u30eb\u30bb\u30df\u30ca\u30fc-\u7121\u6599\">\u30c6\u30af\u30cb\u30ab\u30eb\u30bb\u30df\u30ca\u30fc\uff08\u7121\u6599\uff09<\/h4>\n\n\n\n<p>\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b<br \/><br \/><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/vector-maps.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u304a\u7533\u8fbc\u307f\u306f\u3053\u3061\u3089<\/a><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0-\u6709\u511f\">\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\uff08\u6709\u511f\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u521d\u3081\u3066\u306e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0 \u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0<br><br><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/cloning.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u304a\u7533\u8fbc\u307f\u306f\u3053\u3061\u3089<\/a><\/p>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\u30ac\u30a4\u30c9-\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\">\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\u30ac\u30a4\u30c9 \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h4>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/vector-map-guide.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-\u7121\u6599\u516c\u958b\u4e2d-protein-expression\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\">\u3010\u7121\u6599\u516c\u958b\u4e2d\u3011Protein Expression\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30bf\u30f3\u30d1\u30af\u767a\u73fe\u306e\u5b9f\u9a13\u3092\u691c\u8a0e\u3057\u3066\u3044\u308b\u65b9\u3084\u3001\u8a73\u7d30\u60c5\u5831\u3092\u78ba\u8a8d\u3057\u305f\u3044\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002<br><br><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/protein-expression-handbook-download.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u672c\u30d6\u30ed\u30b0\u306b\u95a2\u9023\u3059\u308b\u30ea\u30f3\u30af\">\u672c\u30d6\u30ed\u30b0\u306b\u95a2\u9023\u3059\u308b\u30ea\u30f3\u30af<\/h4>\n\n\n\n<ul style=\"background-color:#c2c2c221\" class=\"wp-block-list has-background\">\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-bid-ts-1\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u3000 \u7b2c1\u56de\u3000\u30d7\u30e9\u30b9\u30df\u30c9\u30d9\u30af\u30bf\u30fc\u306e\u69cb\u9020\u3068\u30de\u30c3\u30d7\u304b\u3089\u5206\u304b\u308b\u3053\u3068<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-2-bid-ts-mbr-24076\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u3000 \u7b2c2\u56de\u3000\u30d7\u30e9\u30b9\u30df\u30c9\u30d9\u30af\u30bf\u30fc\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u30ea\u30b9\u30c8<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-3-bid-ts-mbr-25003\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_protein_expression_cloning_bid_ts_mbr_25035_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u3000 \u7b2c3\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\u30fb\u5b9f\u4f8b\u96c61<\/a><\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Zeocin is a trademark of InvivoGen.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u3055\u3066\u3001\u7b2c4\u56de\u3067\u3059\u3002\u7b2c3\u56de\u306b\u5f15\u304d\u7d9a\u304d\u3001\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u54fa\u4e73\u985e\u7d30\u80de\u4ee5\u5916\u306e\u767a\u73fe\u7cfb\u7528\u30d9\u30af\u30bf\u30fc\u306e\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u307e\u305a\u6700\u521d\u306b\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u3064\u3044\u3066\u3067\u304d\u308b\u3060\u3051\u7c21\u5358\u306b\u307e\u3068<\/p>\n","protected":false},"author":975,"featured_media":21409,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[14,168],"division":[],"class_list":["post-21407","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-cloning","tag-protein-expression","entry"],"_selected_authors":[],"_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62\" \/>\n<meta property=\"og:description\" content=\"\u3055\u3066\u3001\u7b2c4\u56de\u3067\u3059\u3002\u7b2c3\u56de\u306b\u5f15\u304d\u7d9a\u304d\u3001\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u54fa\u4e73\u985e\u7d30\u80de\u4ee5\u5916\u306e\u767a\u73fe\u7cfb\u7528\u30d9\u30af\u30bf\u30fc\u306e\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u307e\u305a\u6700\u521d\u306b\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u3064\u3044\u3066\u3067\u304d\u308b\u3060\u3051\u7c21\u5358\u306b\u307e\u3068\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-12T06:15:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-12T06:15:43+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png\" \/>\n\t<meta property=\"og:image:width\" content=\"549\" \/>\n\t<meta property=\"og:image:height\" content=\"569\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"22\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62\",\"datePublished\":\"2025-06-12T06:15:39+00:00\",\"dateModified\":\"2025-06-12T06:15:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/\"},\"wordCount\":294,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/06\\\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png\",\"keywords\":[\"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\",\"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/\",\"name\":\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/06\\\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png\",\"datePublished\":\"2025-06-12T06:15:39+00:00\",\"dateModified\":\"2025-06-12T06:15:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/06\\\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/06\\\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png\",\"width\":549,\"height\":569},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/protein-expression-cloning-bid-ts-mbr-25035\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62","og_description":"\u3055\u3066\u3001\u7b2c4\u56de\u3067\u3059\u3002\u7b2c3\u56de\u306b\u5f15\u304d\u7d9a\u304d\u3001\u5b9f\u4f8b\u3092\u4f7f\u3063\u3066\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u89e3\u8aad\u306e\u6d41\u308c\u3092\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u4eca\u56de\u306f\u54fa\u4e73\u985e\u7d30\u80de\u4ee5\u5916\u306e\u767a\u73fe\u7cfb\u7528\u30d9\u30af\u30bf\u30fc\u306e\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 \u307e\u305a\u6700\u521d\u306b\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306b\u542b\u307e\u308c\u308b\u30a8\u30ec\u30e1\u30f3\u30c8\u306b\u3064\u3044\u3066\u3067\u304d\u308b\u3060\u3051\u7c21\u5358\u306b\u307e\u3068","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-06-12T06:15:39+00:00","article_modified_time":"2025-06-12T06:15:43+00:00","og_image":[{"width":549,"height":569,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"22\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62","datePublished":"2025-06-12T06:15:39+00:00","dateModified":"2025-06-12T06:15:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/"},"wordCount":294,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png","keywords":["\u30af\u30ed\u30fc\u30cb\u30f3\u30b0","\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/","name":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png","datePublished":"2025-06-12T06:15:39+00:00","dateModified":"2025-06-12T06:15:43+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png","width":549,"height":569},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25035\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff5e\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u30fb\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u3067\u8ff7\u5b50\u306b\u306a\u3089\u306a\u3044\u305f\u3081\u306b\u7b2c4\u56de\u3000\u30d9\u30af\u30bf\u30fc\u30de\u30c3\u30d7\u306e\u8aad\u307f\u65b9\uff1a\u5b9f\u4f8b\u96c62"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":14,"label":"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0"},{"value":168,"label":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png",549,569,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":14,"name":"\u30af\u30ed\u30fc\u30cb\u30f3\u30b0","slug":"cloning","term_group":0,"term_taxonomy_id":14,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]},{"term_id":168,"name":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe","slug":"protein-expression","term_group":0,"term_taxonomy_id":168,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/protein-expression-cloning-bid-ts-mbr-25035_eyecatch.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/21407","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=21407"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/21407\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/21409"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=21407"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=21407"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=21407"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=21407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}