{"id":21873,"date":"2025-06-26T12:08:16","date_gmt":"2025-06-26T03:08:16","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=21873"},"modified":"2025-08-14T18:52:54","modified_gmt":"2025-08-14T09:52:54","slug":"battery-manufacturing-battery-development-cad-25039","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/","title":{"rendered":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u3001\u643a\u5e2f\u6a5f\u5668\u306e\u9032\u5316\u306b\u5f93\u3044\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u52b9\u7387\u306e\u5411\u4e0a\u3068\u74b0\u5883\u4fdd\u8b77\u3092\u4e21\u7acb\u3057\u305f\u30d0\u30c3\u30c6\u30ea\u30fc\u3068\u305d\u306e\u88fd\u9020\u65b9\u6cd5\u306e\u958b\u767a\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u5f93\u6765\u306e\u96fb\u6975\u88fd\u9020\u624b\u6cd5\u3068\u306e\u6bd4\u8f03\u3084\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u308b\u3053\u3068\u306e\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\"><strong>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306e\u52b9\u7387\u5316\u3001\u54c1\u8cea\u5b89\u5b9a\u5316\u3092\u884c\u3044\u305f\u3044<\/strong><\/li>\n\n\n\n<li><strong>\u7814\u7a76\u958b\u767a\u3092\u52a0\u901f\u3001\u751f\u7523\u6027\u3092\u5411\u4e0a\u3055\u305b\u308b\u30c4\u30fc\u30eb\u3092\u63a2\u3057\u3066\u3044\u308b<\/strong><\/li>\n\n\n\n<li><strong>\u74b0\u5883\u3084\u30b3\u30b9\u30c8\u306b\u914d\u616e\u3057\u305f\u3001\u65b0\u305f\u306a\u88fd\u9020\u624b\u6cd5\u3092\u958b\u767a\u3057\u305f\u3044<\/strong><\/li>\n<\/ul>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306f\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\">\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d0\u30c3\u30c6\u30ea\u30fc\u30b9\u30e9\u30ea\u30fc\u306f\u3001\u901a\u5e38\u3001\u30d7\u30e9\u30cd\u30bf\u30ea\u30fc\u30df\u30ad\u30b5\u30fc\u306a\u3069\u306e\u64b9\u62cc\u5bb9\u5668\u5185\u3067\u6d3b\u7269\u8cea\u3001\u30ab\u30fc\u30dc\u30f3\u30d6\u30e9\u30c3\u30af\u3001\u6eb6\u5264\u3001\u30d0\u30a4\u30f3\u30c0\u30fc\u3001\u6dfb\u52a0\u5264\u3092\u30d0\u30c3\u30c1\u3054\u3068\u306b\u914d\u5408\u3057\u3066\u88fd\u9020\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306b\u306f\u30d0\u30c3\u30c1\u9593\u3067\u306e\u5909\u52d5\u306e\u30ea\u30b9\u30af\u304c\u3042\u308a\u3001\u52b4\u529b\u304c\u304b\u304b\u308b\u306e\u3067\u3001\u751f\u7523\u306b\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u304c\u767a\u751f\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30e9\u30dc\u30b9\u30b1\u30fc\u30eb\u3067\u958b\u767a\u3057\u305f\u65b0\u898f\u8abf\u5408\u3092\u751f\u7523\u30b9\u30b1\u30fc\u30eb\u306b\u79fb\u884c\u3059\u308b\u3053\u3068\u306f\u7c21\u5358\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3088\u308b\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\">\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3088\u308b\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u3001\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u30d0\u30c3\u30c1\u5f0f\u6df7\u5408\u3092\u7f6e\u304d\u63db\u3048\u308b\u6280\u8853\u3067\u3059\u3002\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u3067\u914d\u5408\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u6750\u6599\u305b\u3093\u65ad\u306e\u6b63\u78ba\u306a\u5236\u5fa1\u3001\u71b1\u4f1d\u9054\u3001\u6750\u6599\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3001\u304a\u3088\u3073\u6ede\u7559\u6642\u9593\u3092\u5099\u3048\u305f\u9023\u7d9a\u751f\u7523\u30d7\u30ed\u30bb\u30b9\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u518d\u73fe\u6027\u304c\u9ad8\u307e\u308a\u3001\u6d17\u6d44\u6642\u9593\u3092\u77ed\u7e2e\u3057\u3001\u6750\u6599\u52b9\u7387\u3092\u5411\u4e0a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"413\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/fca3d0968b59334a64a46347c3fecce8-1024x413.png\" alt=\"\" class=\"wp-image-21875\" style=\"width:736px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/fca3d0968b59334a64a46347c3fecce8-1024x413.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/fca3d0968b59334a64a46347c3fecce8-300x121.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/fca3d0968b59334a64a46347c3fecce8-768x310.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/fca3d0968b59334a64a46347c3fecce8-1536x619.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/fca3d0968b59334a64a46347c3fecce8-2048x826.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>\u5199\u771f\uff1aProcess 11\u88c5\u7f6e\u69cb\u6210\u3068\u30b9\u30e9\u30ea\u30fc\u914d\u5408<\/strong><\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u5de6\u306e\u5199\u771f\u306f\u88c5\u7f6e\u306e\u69cb\u6210\u3067\u3059\u3002Thermo Scientific\u2122 Process\u2122 11\u5353\u4e0a\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3068\u7c89\u4f53\u6750\u6599\u3092\u4f9b\u7d66\u3059\u308b\u30d5\u30a3\u30fc\u30c0\u30fc\u3001\u6eb6\u5a92\u3092\u4f9b\u7d66\u3059\u308b\u30dd\u30f3\u30d7\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002Process 11\u306f\u5c0f\u578b\u306e\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306e\u305f\u3081\u3001\u5b89\u5168\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\u3084\u30b0\u30ed\u30fc\u30d6\u30dc\u30c3\u30af\u30b9\u5185\u306b\u8a2d\u7f6e\u3067\u304d\u30010.1\uff5e4.5 kg\/h\u306e\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3067\u30b5\u30f3\u30d7\u30eb\u3092\u4f5c\u88fd\u3067\u304d\u307e\u3059\u3002\u3053\u3053\u304b\u3089\u88c5\u7f6e\u3092\u30b9\u30b1\u30fc\u30eb\u30a2\u30c3\u30d7\u3059\u308b\u3053\u3068\u3067\u3001\u3088\u308a\u9ad8\u3044\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5b9f\u73fe\u3059\u308b\u3053\u3068\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u7528\u3044\u308b\u30e1\u30ea\u30c3\u30c8\">\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3092\u7528\u3044\u308b\u30e1\u30ea\u30c3\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d7\u30e9\u30cd\u30bf\u30ea\u30fc\u30df\u30ad\u30b5\u30fc\u3067\u306e\u30d0\u30c3\u30c1\u6df7\u5408\u3068\u6bd4\u8f03\u3059\u308b\u3068\u3001\u9023\u7d9a\u5f0f\u30d7\u30ed\u30bb\u30b9\u306e\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u3055\u307e\u3056\u307e\u306a\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u9ad8\u3044\u518d\u73fe\u6027\">\u30fb\u9ad8\u3044\u518d\u73fe\u6027<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u9023\u7d9a\u5f0f\u30d7\u30ed\u30bb\u30b9\u306b\u306f\u30d0\u30c3\u30c1\u304c\u306a\u3044\u305f\u3081\u3001\u30d0\u30c3\u30c1\u9593\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u304c\u767a\u751f\u3057\u307e\u305b\u3093\u3002\u5909\u52d5\u306e\u306a\u3044\u30b9\u30e9\u30ea\u30fc\u3092\u9023\u7d9a\u7684\u306b\u751f\u6210\u3057\u7d9a\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u9ad8\u3044\u5206\u6563\u54c1\u8cea\">\u30fb\u9ad8\u3044\u5206\u6563\u54c1\u8cea<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u6750\u6599\u306b\u4f5c\u7528\u3059\u308b\u305b\u3093\u65ad\u529b\u304c\u30d7\u30e9\u30cd\u30bf\u30ea\u30fc\u30df\u30ad\u30b5\u30fc\u3088\u308a\u3082\u9ad8\u3044\u305f\u3081\u3001\u30b9\u30e9\u30ea\u30fc\u306e\u5206\u6563\u54c1\u8cea\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u6642\u306e\u30b9\u30af\u30ea\u30fc\u30f3\u30d5\u30a3\u30eb\u30bf\u30fc\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3082\u4f4e\u6e1b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"363\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/62312df3225732fa5ae13d5630efb4a2-1024x363.png\" alt=\"\" class=\"wp-image-21891\" style=\"width:700px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/62312df3225732fa5ae13d5630efb4a2-1024x363.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/62312df3225732fa5ae13d5630efb4a2-300x106.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/62312df3225732fa5ae13d5630efb4a2-768x272.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/62312df3225732fa5ae13d5630efb4a2-1536x544.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/62312df3225732fa5ae13d5630efb4a2-2048x726.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u9ad8\u3044\u751f\u7523\u6027-\u30b9\u30da\u30fc\u30b9-\u6750\u6599-\u52b4\u529b-\u6642\u9593\u306e\u7bc0\u7d04\">\u30fb\u9ad8\u3044\u751f\u7523\u6027\uff08\u30b9\u30da\u30fc\u30b9\u3001\u6750\u6599\u3001\u52b4\u529b\u3001\u6642\u9593\u306e\u7bc0\u7d04\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u9023\u7d9a\u5f0f\u30d7\u30ed\u30bb\u30b9\u306f\u6750\u6599\u640d\u5931\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u308b\u305f\u3081\u3001\u3088\u308a\u901f\u304f\u3001\u3088\u308a\u6750\u6599\u52b9\u7387\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u30b9\u30e9\u30ea\u30fc\u306e\u30d0\u30c3\u30c1\u306f\u30d7\u30e9\u30cd\u30bf\u30ea\u30fc\u30df\u30ad\u30b5\u30fc\u3067\u6df7\u5408\u3059\u308b\u306e\u306b4\u6642\u9593\u304b\u30898\u6642\u9593\u304b\u304b\u308a\u307e\u3059\u304c\u3001\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3067\u306f\u6570\u5206\u4ee5\u5185\u3067\u88fd\u9020\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"400\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/befca60c38b522268234edddafc0880c-1024x400.png\" alt=\"\" class=\"wp-image-21880\" style=\"width:700px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/befca60c38b522268234edddafc0880c-1024x400.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/befca60c38b522268234edddafc0880c-300x117.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/befca60c38b522268234edddafc0880c-768x300.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/befca60c38b522268234edddafc0880c-1536x600.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/befca60c38b522268234edddafc0880c-2048x800.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u306b\u5bfe\u3057\u3066\u3001\u9023\u7d9a\u30d7\u30ed\u30bb\u30b9\u65b9\u5f0f\u3067\u306f\u3001\u30b9\u30e9\u30ea\u30fc\u56de\u53ce\u306e\u305f\u3081\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u304c\u3042\u308a\u307e\u305b\u3093\u3002\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3088\u308b\u9023\u7d9a\u30d7\u30ed\u30bb\u30b9\u306f\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\uff08\u6750\u6599\u914d\u5408\u6bd4\u3001\u6750\u6599\u4f9b\u7d66\u901f\u5ea6\u3001\u6e29\u5ea6\u3001\u30b9\u30af\u30ea\u30e5\u30fc\u56de\u8ee2\u901f\u5ea6\uff09\u3092\u30d7\u30ed\u30bb\u30b9\u4e2d\u3067\u3082\u5bb9\u6613\u306b\u5909\u66f4\u3067\u304d\u308b\u305f\u3081\u30011\u5ea6\u306e\u30d7\u30ed\u30bb\u30b9\u3067\u8907\u6570\u306e\u7279\u6027\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u4f5c\u88fd\u3001\u6bd4\u8f03\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"984\" height=\"610\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/8afa2bd33300bbff89d47519bd74d34a.jpg\" alt=\"\" class=\"wp-image-21881\" style=\"width:560px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/8afa2bd33300bbff89d47519bd74d34a.jpg 984w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/8afa2bd33300bbff89d47519bd74d34a-300x186.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/8afa2bd33300bbff89d47519bd74d34a-768x476.jpg 768w\" sizes=\"auto, (max-width: 984px) 100vw, 984px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"499\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/abd494de1dec95297fc2c1f0bf6cc9e0-1024x499.jpg\" alt=\"\" class=\"wp-image-21882\" style=\"width:700px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/abd494de1dec95297fc2c1f0bf6cc9e0-1024x499.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/abd494de1dec95297fc2c1f0bf6cc9e0-300x146.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/abd494de1dec95297fc2c1f0bf6cc9e0-768x374.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/06\/abd494de1dec95297fc2c1f0bf6cc9e0.jpg 1306w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u306e\u5199\u771f\u306f\u7570\u306a\u308b\u30d7\u30ed\u30bb\u30b9\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3067\u4f5c\u6210\u3057\u305f\u30b9\u30e9\u30ea\u30fc\u306e\u30b0\u30e9\u30a4\u30f3\u30c9\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u7c92\u5b50\u30b5\u30a4\u30ba\u306e\u6bd4\u8f03\u3068\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u306b\u3088\u308b\u30ec\u30aa\u30ed\u30b8\u30fc\u7279\u6027\u306e\u6bd4\u8f03\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u88fd\u9020\u306b\u304a\u3044\u3066\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306f\u30d0\u30c3\u30c1\u5f0f\u88fd\u9020\u306b\u7f6e\u304d\u63db\u3048\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u624b\u6cd5\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u958b\u767a\u306b\u304a\u3044\u3066\u9ad8\u3044\u54c1\u8cea\u3001\u518d\u73fe\u6027\u306e\u30b9\u30e9\u30ea\u30fc\u88fd\u9020\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u751f\u7523\u6027\u306e\u9ad8\u3044\u30d7\u30ed\u30bb\u30b9\u3092\u63d0\u4f9b\u3067\u304d\u3001\u7814\u7a76\u958b\u767a\u3092\u52a0\u901f\u3055\u305b\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u30e9\u30dc\u3067\u78ba\u7acb\u3055\u308c\u305f\u30d7\u30ed\u30bb\u30b9\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u751f\u7523\u898f\u6a21\u306e\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u3078\u5bb9\u6613\u306b\u79fb\u884c\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u95a2\u9023\u60c5\u5831\">\u95a2\u9023\u60c5\u5831<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment.html?CID=battery_manufacturing_battery_development_cad_25039_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u304a\u3088\u3073\u6df7\u932c\u62bc<\/a><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment.html?CID=battery_manufacturing_battery_development_cad_25039_Social_LAB\">\u51fa<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/resources.html#e-learning?CID=battery_manufacturing_battery_development_cad_25039_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3064\u3044\u3066\u5b66\u3079\u308be-learning<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f53\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u88fd\u54c1\u3092\u53d6\u308a\u6271\u3063\u3066\u3044\u307e\u3059\u3002\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3053\u3061\u3089\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/extruder.html?CID=battery_manufacturing_battery_development_cad_25039_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba-\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\uff0f\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089<\/h4>\n\n\n\n<ul style=\"background-color:#f7f7f7\" class=\"wp-block-list has-background\">\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/?CID=battery_manufacturing_battery_development_cad_25039_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780 \u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/?CID=battery_manufacturing_battery_development_cad_25039_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461 \u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/?CID=battery_manufacturing_battery_development_cad_25039_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9<\/a><\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u3001\u643a\u5e2f\u6a5f\u5668\u306e\u9032\u5316\u306b\u5f93\u3044\u3001\u30a8\u30cd\u30eb\u30ae\u30fc\u52b9\u7387\u306e\u5411\u4e0a\u3068\u74b0\u5883\u4fdd\u8b77\u3092\u4e21\u7acb\u3057\u305f\u30d0\u30c3\u30c6\u30ea\u30fc\u3068\u305d\u306e\u88fd\u9020\u65b9\u6cd5\u306e\u958b\u767a\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u3053\u306e\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u3001\u5f93\u6765\u306e\u96fb\u6975\u88fd\u9020\u624b\u6cd5\u3068\u306e\u6bd4\u8f03<\/p>\n","protected":false},"author":975,"featured_media":20253,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155],"tags":[235,236],"division":[],"class_list":["post-21873","post","type-post","status-publish","format-standard","has-post-thumbnail","category-else","tag-235","tag-battery-development","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u3001\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u30b7\u30ea\u30fc\u30ba\u7b2c2\u56de\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\" \/>\n<meta property=\"og:description\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u3001\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u30b7\u30ea\u30fc\u30ba\u7b2c2\u56de\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-26T03:08:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-14T09:52:54+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2107\" \/>\n\t<meta property=\"og:image:height\" content=\"1117\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\",\"datePublished\":\"2025-06-26T03:08:16+00:00\",\"dateModified\":\"2025-08-14T09:52:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/\"},\"wordCount\":9,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"keywords\":[\"\u96fb\u6975\u88fd\u9020\",\"\u96fb\u6c60\u958b\u767a\"],\"articleSection\":[\"\u305d\u306e\u4ed6\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/\",\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"datePublished\":\"2025-06-26T03:08:16+00:00\",\"dateModified\":\"2025-08-14T09:52:54+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"description\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u3001\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u30b7\u30ea\u30fc\u30ba\u7b2c2\u56de\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/04\\\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg\",\"width\":2107,\"height\":1117},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-manufacturing-battery-development-cad-25039\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408 - Learning at the Bench","description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u3001\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u30b7\u30ea\u30fc\u30ba\u7b2c2\u56de\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/","og_locale":"ja_JP","og_type":"article","og_title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408","og_description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u3001\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u30b7\u30ea\u30fc\u30ba\u7b2c2\u56de\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-06-26T03:08:16+00:00","article_modified_time":"2025-08-14T09:52:54+00:00","og_image":[{"width":2107,"height":1117,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408","datePublished":"2025-06-26T03:08:16+00:00","dateModified":"2025-08-14T09:52:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/"},"wordCount":9,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","keywords":["\u96fb\u6975\u88fd\u9020","\u96fb\u6c60\u958b\u767a"],"articleSection":["\u305d\u306e\u4ed6"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/","name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","datePublished":"2025-06-26T03:08:16+00:00","dateModified":"2025-08-14T09:52:54+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u7528\u3044\u305f\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u96fb\u6975\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u518d\u751f\u53ef\u80fd\u30a8\u30cd\u30eb\u30ae\u30fc\u3084EV\u306e\u666e\u53ca\u306b\u4f34\u3044\u9032\u5316\u3059\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u88fd\u9020\u306b\u304a\u3051\u308b\u3001\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff08\u4e8c\u8ef8\u30b9\u30af\u30ea\u30e5\u30fc\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u96fb\u6975\u88fd\u9020\u30e1\u30ea\u30c3\u30c8\u3092\u7d39\u4ecb\u3059\u308b\u30b7\u30ea\u30fc\u30ba\u7b2c2\u56de\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","width":2107,"height":1117},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"\u305d\u306e\u4ed6"}],"post_tag":[{"value":235,"label":"\u96fb\u6975\u88fd\u9020"},{"value":236,"label":"\u96fb\u6c60\u958b\u767a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch-1024x543.jpg",760,403,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":155,"name":"\u305d\u306e\u4ed6","slug":"else","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":63,"filter":"raw","meta":[],"cat_ID":155,"category_count":63,"category_description":"","cat_name":"\u305d\u306e\u4ed6","category_nicename":"else","category_parent":0}],"tag_info":[{"term_id":235,"name":"\u96fb\u6975\u88fd\u9020","slug":"%e9%9b%bb%e6%a5%b5%e8%a3%bd%e9%80%a0","term_group":0,"term_taxonomy_id":235,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":236,"name":"\u96fb\u6c60\u958b\u767a","slug":"battery-development","term_group":0,"term_taxonomy_id":236,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/04\/battery-manufacturing-battery-development-cad-25021_eyecatch.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/21873","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=21873"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/21873\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/20253"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=21873"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=21873"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=21873"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=21873"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}