{"id":22741,"date":"2025-08-22T10:19:32","date_gmt":"2025-08-22T01:19:32","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=22741"},"modified":"2025-11-12T17:29:50","modified_gmt":"2025-11-12T08:29:50","slug":"twin-screw-extrusion-battery-development-cad-25053","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/","title":{"rendered":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6"},"content":{"rendered":"\n<p>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u62bc\u51fa\u6210\u5f62\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p><strong>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u306a\u3093\u3068\u306a\u304f\u4f7f\u3063\u3066\u3044\u308b\u3051\u308c\u3069\u3001\u3082\u3063\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u3053\u3068\u3092\u7406\u89e3\u3057\u305f\u3044<\/strong><\/li>\n\n\n\n<li><strong>\u88c5\u7f6e\u69cb\u6210\u3084\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u5909\u66f4\u3057\u305f\u3044\u3051\u3069\u3001\u3069\u3046\u3057\u305f\u3089\u3088\u3044\u304b\u4e0d\u5b89<\/strong><\/li>\n\n\n\n<li><strong>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u3092\u3082\u3063\u3068\u4f7f\u3044\u3053\u306a\u3057\u305f\u3044\u3001\u3082\u3063\u3068\u6d3b\u7528\u3057\u305f\u3044<\/strong><\/li>\n<\/ul>\n<\/div>\n\n\n\n<p>\u4eca\u56de\u306f\u30d0\u30ec\u30eb\u3084\u30c0\u30a4\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027\">\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p>\u4e8c\u8ef8\u6df7\u932c\u62bc\u51fa\u306b\u304a\u3044\u3066\u9069\u5207\u306b\u6e29\u5ea6\u3092\u5236\u5fa1\u3059\u308b\u3053\u3068\u306f\u3068\u3066\u3082\u91cd\u8981\u306a\u8981\u7d20\u306e\u4e00\u3064\u3067\u3001\u4ee5\u4e0b\u306e\u9805\u76ee\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u6750\u6599\u306e\u5747\u4e00\u306a\u6eb6\u878d\">\u30fb\u6750\u6599\u306e\u5747\u4e00\u306a\u6eb6\u878d<\/h3>\n\n\n\n<p>\u6e29\u5ea6\u304c\u9069\u5207\u3067\u306a\u3044\u3068\u3001\u6750\u6599\u304c\u5747\u4e00\u306b\u6eb6\u878d\u305b\u305a\u3001\u88fd\u54c1\u306b\u4e0d\u5747\u4e00\u6027\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u71b1\u5206\u89e3\u306e\u9632\u6b62\">\u30fb\u71b1\u5206\u89e3\u306e\u9632\u6b62<\/h3>\n\n\n\n<p>\u904e\u5ea6\u306b\u9ad8\u3044\u6e29\u5ea6\u3067\u306f\u3001\u6750\u6599\u304c\u71b1\u5206\u89e3\u3092\u8d77\u3053\u3057\u3001\u7269\u6027\u306e\u4f4e\u4e0b\u3084\u5371\u967a\u7269\u8cea\u306e\u767a\u751f\u306a\u3069\u671b\u307e\u3057\u304f\u306a\u3044\u5316\u5b66\u5909\u5316\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u7c98\u5ea6\u306e\u5236\u5fa1\">\u30fb\u7c98\u5ea6\u306e\u5236\u5fa1<\/h3>\n\n\n\n<p>\u6e29\u5ea6\u306f\u6750\u6599\u306e\u7c98\u5ea6\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u9069\u5207\u306a\u7c98\u5ea6\u3092\u7dad\u6301\u3059\u308b\u3053\u3068\u3067\u3001\u62bc\u51fa\u30d7\u30ed\u30bb\u30b9\u304c\u5b89\u5b9a\u3057\u3001\u88fd\u54c1\u306e\u54c1\u8cea\u304c\u4fdd\u305f\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5316\u5b66\u53cd\u5fdc\u306e\u6700\u9069\u5316\">\u30fb\u5316\u5b66\u53cd\u5fdc\u306e\u6700\u9069\u5316<\/h3>\n\n\n\n<p>\u7279\u306b\u8907\u6570\u306e\u6210\u5206\u304b\u3089\u306a\u308b\u6750\u6599\u306e\u5834\u5408\u3001\u5404\u6210\u5206\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u6700\u9069\u5316\u3059\u308b\u6e29\u5ea6\u304c\u5fc5\u8981\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u6750\u6599\u306e\u7269\u7406\u7684\u7279\u6027\u3084\u6027\u80fd\u304c\u6700\u5927\u5316\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u306e\u78ba\u8a8d\">\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u306e\u78ba\u8a8d<\/h2>\n\n\n\n<p>\u6750\u6599\u6210\u5206\u306e\u7279\u6027\u306b\u95a2\u3059\u308b\u60c5\u5831\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3067\u3001\u6e29\u5ea6\u8a2d\u5b9a\u306e\u53c2\u8003\u306b\u3067\u304d\u307e\u3059\u3002\u57fa\u672c\u7684\u306a\u78ba\u8a8d\u4e8b\u9805\u306f\u6b21\u306e\u3068\u304a\u308a\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6750\u6599\u304c\u52a0\u71b1\u3055\u308c\u308b\u3068\u4f55\u304c\u8d77\u3053\u308b\u306e\u304b\uff1f<\/li>\n\n\n\n<li>\u6eb6\u878d\u70b9\uff0f\u30ac\u30e9\u30b9\u8ee2\u79fb\u306f\u4f55\u5ea6\u304b\uff1f<\/li>\n\n\n\n<li>\u6750\u6599\u304c\u5206\u89e3\u3059\u308b\u306e\u306f\u3069\u306e\u6e29\u5ea6\u304b\uff1f<\/li>\n\n\n\n<li>\u62bc\u51fa\u306b\u6700\u9069\u306a\u6e29\u5ea6\u7bc4\u56f2\u306f\u3069\u3053\u304b\uff1f<\/li>\n<\/ul>\n\n\n\n<p>\u3053\u308c\u3089\u306e\u60c5\u5831\u306f\u3001\u591a\u304f\u306e\u5834\u5408\u3001\u6750\u6599\u306e\u30b5\u30d7\u30e9\u30a4\u30e4\u30fc\u304b\u3089\u5165\u624b\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u4e00\u65b9\u3067\u3001\u8907\u6570\u306e\u6210\u5206\u304c\u914d\u5408\u3055\u308c\u305f\u6750\u6599\u306e\u5834\u5408\u306f\u5358\u4e00\u6210\u5206\u306e\u5834\u5408\u3068\u7570\u306a\u308b\u71b1\u7684\u7279\u6027\u3092\u793a\u3059\u305f\u3081\u3001\u914d\u5408\u3055\u308c\u305f\u72b6\u614b\u3067\u306e\u6750\u6599\u306e\u7279\u6027\u3092\u78ba\u8a8d\u3001\u7406\u89e3\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"377\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/f1c454576d726c54ee1140681a241bf9-1024x377.jpg\" alt=\"\" class=\"wp-image-22748\" style=\"width:600px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/f1c454576d726c54ee1140681a241bf9-1024x377.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/f1c454576d726c54ee1140681a241bf9-300x110.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/f1c454576d726c54ee1140681a241bf9-768x283.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/f1c454576d726c54ee1140681a241bf9-1536x565.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/f1c454576d726c54ee1140681a241bf9-2048x754.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u8907\u5408\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u306e\u78ba\u8a8d-\u71b1\u5206\u6790\">\u8907\u5408\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u306e\u78ba\u8a8d \u71b1\u5206\u6790<\/h2>\n\n\n\n<p>\u793a\u5dee\u8d70\u67fb\u71b1\u5206\u6790\u8a08\uff08DSC\uff09\u306f\u3001\u5358\u4e00\u306e\u6210\u5206\u3068\u914d\u5408\u7269\u306e\u76f8\u5909\u5316\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4e0b\u306e\u56f3\u306f\u3001\u533b\u85ac\u54c1\u6709\u52b9\u6210\u5206\uff08API\uff09\u306e\u30a4\u30d6\u30d7\u30ed\u30d5\u30a7\u30f3\u3068\u6c34\u6eb6\u6027\u30dd\u30ea\u30de\u30fc\u306eSoluplus\u00ae\uff08BASF\u3001Ludwigshafen\u3001 Germany\uff09\u3092\u3001\u305d\u308c\u305e\u308c\u306e\u5358\u4e00\u6210\u5206\u3068\u914d\u5408\u3057\u305f\u6750\u6599\u306eDSC\u6e2c\u5b9a\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"561\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_figure-5-hi-res-1024x561.png\" alt=\"\" class=\"wp-image-22752\" style=\"width:699px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_figure-5-hi-res-1024x561.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_figure-5-hi-res-300x164.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_figure-5-hi-res-768x420.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_figure-5-hi-res-1536x841.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_figure-5-hi-res-2048x1121.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Soluplus\u306e\u30ac\u30e9\u30b9\u8ee2\u79fb\u306f\u304a\u304a\u3088\u305d70\u2103\u3001\u914d\u5408\u3057\u305f\u6750\u6599\u306e\u6eb6\u878d\u70b9\u306f73 \u2103\u3067\u3001\u3053\u308c\u304c\u6eb6\u878d\u4f53\u3092\u5f97\u308b\u305f\u3081\u306e\u6700\u4f4e\u6e29\u5ea6\u3067\u3059\u3002\u30a4\u30d6\u30d7\u30ed\u30d5\u30a7\u30f3\u306f145\u2103\u304b\u3089\u5206\u89e3\u304c\u59cb\u307e\u308a\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u3053\u306e\u914d\u5408\u6750\u6599\u306e\u6eb6\u878d\u6df7\u932c\u53ef\u80fd\u306a\u7bc4\u56f2\u306f70 \u2103\u304b\u3089145 \u2103\u306e\u9593\u3068\u63a8\u5b9a\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u8907\u5408\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u306e\u78ba\u8a8d-\u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790\">\u8907\u5408\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u306e\u78ba\u8a8d \u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790<\/h2>\n\n\n\n<p>\u6e29\u5ea6\u30b9\u30a4\u30fc\u30d7\u6e2c\u5b9a\u6a5f\u80fd\u3092\u6301\u3064\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3067\u71b1\u7684\u7279\u6027\u306e\u5206\u6790\u3092\u3059\u308b\u3053\u3068\u3067\u3001\u3088\u308a\u8a73\u7d30\u306a\u77e5\u898b\u3092\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u4e0b\u306e\u56f3\u306fSoluplus\u5358\u4f53\uff08\u8d64\uff09\u304a\u3088\u3073\u30a4\u30d6\u30d7\u30ed\u30d5\u30a7\u30f3\u3068\u306e\u6df7\u5408\u7269\uff08\u7dd1\uff09\u306e\u6e29\u5ea6\u3068\u7c98\u5ea6\u306e\u95a2\u4fc2\u3092\u5206\u6790\u3057\u305f\u7d50\u679c\u3068\u5206\u6790\u306b\u7528\u3044\u305fThermo Scientific\u2122 HAAKE\u2122 MARS 60\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center has-small-font-size\">\u203b\u753b\u50cf\u3092\u30af\u30ea\u30c3\u30af\u3067\u62e1\u5927<\/p>\n\n\n\n<div class=\"wp-block-group is-content-justification-center is-nowrap is-layout-flex wp-container-core-group-is-layout-94bc23d7 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><a href=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu.jpg\" target=\"_blank\" rel=\" noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"686\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu-1024x686.jpg\" alt=\"Soluplus\u5358\u4f53\uff08\u8d64\uff09\u304a\u3088\u3073\u30a4\u30d6\u30d7\u30ed\u30d5\u30a7\u30f3\u3068\u306e\u6df7\u5408\u7269\uff08\u7dd1\uff09\u306e\u6e29\u5ea6\u3068\u7c98\u5ea6\u306e\u95a2\u4fc2\u3092\u5206\u6790\u3057\u305f\u7d50\u679c\" class=\"wp-image-22757\" style=\"width:520px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu-1024x686.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu-300x201.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu-768x515.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu-1536x1029.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu-96x65.jpg 96w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_fig9_b_soluplus_neu.jpg 1567w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure>\n\n\n\n<figure class=\"wp-block-image size-medium\"><a href=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-scaled.jpg\" target=\"_blank\" rel=\" noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"225\" height=\"300\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-225x300.jpg\" alt=\"Thermo Scientific\u2122 HAAKE\u2122 MARS 60\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\" class=\"wp-image-22758\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-225x300.jpg 225w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-767x1024.jpg 767w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-768x1026.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-1150x1536.jpg 1150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-1533x2048.jpg 1533w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/08\/twin-screw-extrusion-battery-development-cad-25053_Mars_40_60-scaled.jpg 1917w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u6e29\u5ea6\u306e\u4e0a\u6607\u3068\u3068\u3082\u306b\u7c98\u5ea6\u304c\u4f4e\u4e0b\u3057\u3066\u3044\u304f\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6df7\u5408\u7269\u306e\u7c98\u5ea6\u66f2\u7dda\u306f\u30dd\u30ea\u30de\u30fc\u5358\u4f53\u3088\u308a\u3082\u4f4e\u6e29\u5074\u306b\u30b7\u30d5\u30c8\u3057\u3066\u304a\u308a\u3001\u30a4\u30d6\u30d7\u30ed\u30d5\u30a7\u30f3\uff08API\uff09\u306fSoluplus\uff08\u30dd\u30ea\u30de\u30fc\uff09\u306b\u5bfe\u3057\u3066\u53ef\u5851\u5316\u52b9\u679c\u3092\u4e0e\u3048\u3001\u30dd\u30ea\u30de\u30fc\u5358\u4f53\u306e\u6642\u3088\u308a\u3082\u4f4e\u3044\u6e29\u5ea6\u3067\u7c98\u5ea6\u304c\u4e0b\u304c\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u6eb6\u878d\u6df7\u932c\u62bc\u51fa\u306b\u9069\u3057\u305f\u7c98\u5ea6\u306e\u7bc4\u56f2\u306f600\uff5e10,000 Pa\u30fbs\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u3053\u306e\u3053\u3068\u304b\u3089\u7d0470 \u2103\u304b\u3089105 \u2103\u307e\u3067\u306e\u7bc4\u56f2\u304c\u6eb6\u878d\u6df7\u932c\u30d7\u30ed\u30bb\u30b9\u306b\u9069\u3057\u305f\u6e29\u5ea6\u7bc4\u56f2\u3067\u3042\u308b\u3068\u5206\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p>\u4e8c\u8ef8\u6df7\u932c\u62bc\u51fa\u306b\u304a\u3044\u3066\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u3001\u9069\u5207\u306a\u30d7\u30ed\u30bb\u30b9\u6e29\u5ea6\u8a2d\u5b9a\u3092\u3059\u308b\u3053\u3068\u306f\u3001\u9ad8\u54c1\u8cea\u306a\u30b5\u30f3\u30d7\u30eb\u3092\u5f97\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u5b89\u5168\u6027\u3084\u52b9\u7387\u3068\u3044\u3063\u305f\u70b9\u3067\u3082\u5927\u304d\u306a\u52b9\u679c\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u71b1\u5206\u6790\u88c5\u7f6e\u3084\u30ec\u30aa\u30e1\u30fc\u30bf\u30fc\u3067\u6750\u6599\u306e\u5206\u6790\u3092\u884c\u3046\u3053\u3068\u3067\u3001\u6750\u6599\u306b\u95a2\u3059\u308b\u77e5\u898b\u3092\u6df1\u3081\u3001\u6df7\u932c\u62bc\u51fa\u306e\u30d7\u30ed\u30bb\u30b9\u8a2d\u5b9a\u306e\u6700\u9069\u5316\u3092\u52b9\u7387\u3088\u304f\u5b9f\u884c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-\u95a2\u9023\u60c5\u5831\">\u95a2\u9023\u60c5\u5831<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment.html?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30b3\u30f3\u30d1\u30a6\u30f3\u30c7\u30a3\u30f3\u30b0\u304a\u3088\u3073\u6df7\u932c\u62bc\u51fa<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/manufacturing-processing\/extrusion-compounding-equipment\/resources.html#e-learning?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u306b\u3064\u3044\u3066\u5b66\u3079\u308be-learning<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<p>\u5f53\u793e\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\u88fd\u54c1\u3092\u53d6\u308a\u6271\u3063\u3066\u3044\u307e\u3059\u3002\u3054\u8208\u5473\u306e\u3042\u308b\u65b9\u306f\u3053\u3061\u3089\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/extruder.html?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba-\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\uff0f\u958b\u767a\u30b7\u30ea\u30fc\u30ba\u306f\u3053\u3061\u3089<\/h4>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul style=\"background-color:#f7f7f7\" class=\"wp-block-list has-background\">\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25011\/?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2780 \u62bc\u51fa\u6a5f\uff08\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff09\u306e\u539f\u7406\u3068\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u7279\u9577<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25026\/?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2461 \u30b9\u30af\u30ea\u30e5\u30fc\u3068\u30d0\u30ec\u30eb\u306e\u4ed5\u7d44\u307f<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25047\/?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2462 \u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u30b9\u30af\u30ea\u30e5\u30fc\u306e\u56de\u8ee2\u6570<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25021\/?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2780\uff1a\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u88fd\u9020\u306b\u304a\u3051\u308b\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u5229\u70b9<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-cad-25039\/?CID=twin_screw_extrusion_battery_development_cad_25053_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306b\u3088\u308b\u30d0\u30c3\u30c6\u30ea\u30fc\u96fb\u6975\u306e\u958b\u767a\u2461\uff1a\u30b9\u30e9\u30ea\u30fc\u306e\u914d\u5408<\/a><\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u62bc\u51fa\u6210\u5f62\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002 \u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01 \u4eca\u56de\u306f\u30d0\u30ec\u30eb\u3084\u30c0\u30a4\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306b\u3064\u3044\u3066\u7d39\u4ecb\u3057\u307e\u3059\u3002 <\/p>\n","protected":false},"author":975,"featured_media":19869,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[155],"tags":[234,242,233],"division":[],"class_list":{"0":"post-22741","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-else","8":"tag-extruder","9":"tag-extruder-basic","10":"tag-233","11":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027\u3068\u6700\u9069\u5316\u65b9\u6cd5\u3092\u89e3\u8aac\u3002\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u3001DSC\u3084\u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790\u3092\u6d3b\u7528\u3057\u3066\u9069\u5207\u306a\u6e29\u5ea6\u7bc4\u56f2\u3092\u898b\u6975\u3081\u3001\u9ad8\u54c1\u8cea\u306a\u88fd\u54c1\u3092\u5b89\u5b9a\u3057\u3066\u751f\u7523\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6\" \/>\n<meta property=\"og:description\" content=\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027\u3068\u6700\u9069\u5316\u65b9\u6cd5\u3092\u89e3\u8aac\u3002\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u3001DSC\u3084\u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790\u3092\u6d3b\u7528\u3057\u3066\u9069\u5207\u306a\u6e29\u5ea6\u7bc4\u56f2\u3092\u898b\u6975\u3081\u3001\u9ad8\u54c1\u8cea\u306a\u88fd\u54c1\u3092\u5b89\u5b9a\u3057\u3066\u751f\u7523\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-08-22T01:19:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-12T08:29:50+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\" \/>\n\t<meta property=\"og:image:width\" content=\"778\" \/>\n\t<meta property=\"og:image:height\" content=\"582\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6\",\"datePublished\":\"2025-08-22T01:19:32+00:00\",\"dateModified\":\"2025-11-12T08:29:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/\"},\"wordCount\":18,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"keywords\":[\"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\",\"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8\",\"\u4e8c\u8ef8\u62bc\u51fa\"],\"articleSection\":[\"\u305d\u306e\u4ed6\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/\",\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"datePublished\":\"2025-08-22T01:19:32+00:00\",\"dateModified\":\"2025-11-12T08:29:50+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"description\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027\u3068\u6700\u9069\u5316\u65b9\u6cd5\u3092\u89e3\u8aac\u3002\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u3001DSC\u3084\u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790\u3092\u6d3b\u7528\u3057\u3066\u9069\u5207\u306a\u6e29\u5ea6\u7bc4\u56f2\u3092\u898b\u6975\u3081\u3001\u9ad8\u54c1\u8cea\u306a\u88fd\u54c1\u3092\u5b89\u5b9a\u3057\u3066\u751f\u7523\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/03\\\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png\",\"width\":778,\"height\":582},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/twin-screw-extrusion-battery-development-cad-25053\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6 - Learning at the Bench","description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027\u3068\u6700\u9069\u5316\u65b9\u6cd5\u3092\u89e3\u8aac\u3002\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u3001DSC\u3084\u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790\u3092\u6d3b\u7528\u3057\u3066\u9069\u5207\u306a\u6e29\u5ea6\u7bc4\u56f2\u3092\u898b\u6975\u3081\u3001\u9ad8\u54c1\u8cea\u306a\u88fd\u54c1\u3092\u5b89\u5b9a\u3057\u3066\u751f\u7523\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/","og_locale":"ja_JP","og_type":"article","og_title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6","og_description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027\u3068\u6700\u9069\u5316\u65b9\u6cd5\u3092\u89e3\u8aac\u3002\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u3001DSC\u3084\u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790\u3092\u6d3b\u7528\u3057\u3066\u9069\u5207\u306a\u6e29\u5ea6\u7bc4\u56f2\u3092\u898b\u6975\u3081\u3001\u9ad8\u54c1\u8cea\u306a\u88fd\u54c1\u3092\u5b89\u5b9a\u3057\u3066\u751f\u7523\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-08-22T01:19:32+00:00","article_modified_time":"2025-11-12T08:29:50+00:00","og_image":[{"width":778,"height":582,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6","datePublished":"2025-08-22T01:19:32+00:00","dateModified":"2025-11-12T08:29:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/"},"wordCount":18,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","keywords":["\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc","\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8","\u4e8c\u8ef8\u62bc\u51fa"],"articleSection":["\u305d\u306e\u4ed6"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/","name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","datePublished":"2025-08-22T01:19:32+00:00","dateModified":"2025-11-12T08:29:50+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"description":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u6e29\u5ea6\u8a2d\u5b9a\u306e\u91cd\u8981\u6027\u3068\u6700\u9069\u5316\u65b9\u6cd5\u3092\u89e3\u8aac\u3002\u6750\u6599\u306e\u71b1\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u3001DSC\u3084\u30ec\u30aa\u30ed\u30b8\u30fc\u5206\u6790\u3092\u6d3b\u7528\u3057\u3066\u9069\u5207\u306a\u6e29\u5ea6\u7bc4\u56f2\u3092\u898b\u6975\u3081\u3001\u9ad8\u54c1\u8cea\u306a\u88fd\u54c1\u3092\u5b89\u5b9a\u3057\u3066\u751f\u7523\u3059\u308b\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","width":778,"height":582},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-battery-development-cad-25053\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2463\uff1a\u30d7\u30ed\u30bb\u30b9\u5909\u6570\u8a2d\u5b9a \u6e29\u5ea6"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":155,"label":"\u305d\u306e\u4ed6"}],"post_tag":[{"value":234,"label":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc"},{"value":242,"label":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8"},{"value":233,"label":"\u4e8c\u8ef8\u62bc\u51fa"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png",760,569,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":155,"name":"\u305d\u306e\u4ed6","slug":"else","term_group":0,"term_taxonomy_id":155,"taxonomy":"category","description":"","parent":0,"count":63,"filter":"raw","meta":[],"cat_ID":155,"category_count":63,"category_description":"","cat_name":"\u305d\u306e\u4ed6","category_nicename":"else","category_parent":0}],"tag_info":[{"term_id":234,"name":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc","slug":"extruder","term_group":0,"term_taxonomy_id":234,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":242,"name":"\u30a8\u30af\u30b9\u30c8\u30eb\u30fc\u30c0\u30fc\uff08\u4e8c\u8ef8\u62bc\u51fa\u6a5f\uff09\u57fa\u790e\u7de8","slug":"extruder-basic","term_group":0,"term_taxonomy_id":242,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw","meta":[]},{"term_id":233,"name":"\u4e8c\u8ef8\u62bc\u51fa","slug":"%e4%ba%8c%e8%bb%b8%e6%8a%bc%e5%87%ba","term_group":0,"term_taxonomy_id":233,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/twin-screw-extrusion-extruder-cad-25011_eyecatch.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/22741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=22741"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/22741\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/19869"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=22741"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=22741"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=22741"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=22741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}