{"id":22926,"date":"2025-09-10T07:37:35","date_gmt":"2025-09-09T22:37:35","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=22926"},"modified":"2025-11-05T15:29:59","modified_gmt":"2025-11-05T06:29:59","slug":"nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/","title":{"rendered":"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5"},"content":{"rendered":"\n<p>\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u6cd5\u306f\u3001PCR\u7523\u7269\u3084\u5236\u9650\u9175\u7d20\u6d88\u5316\u65ad\u7247\u306a\u3069\u4e8c\u672c\u9396DNA\u306e\u89e3\u6790\u306b\u4f7f\u3048\u308b\u7c21\u5358\u3067\u4fbf\u5229\u306a\u65b9\u6cd5\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u306fRNA\u306e\u6cf3\u52d5\u306b\u3082\u4f7f\u3048\u307e\u3059\u304c\u3001\u4ee5\u4e0b\u306a\u3069\u306e\u7406\u7531\u3067DNA\u3068\u6bd4\u3079\u3066\u624b\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>RNA\u306f\u4e00\u672c\u9396\u3067\u3042\u308b\u305f\u3081\u4e8c\u6b21\u69cb\u9020\u3092\u5f62\u6210\u3057\u3084\u3059\u304f\u3001\u5909\u6027\u30b2\u30eb\u3092\u4f7f\u3063\u3066\u5909\u6027\u6761\u4ef6\u3067\u96fb\u6c17\u6cf3\u52d5\u3092\u884c\u3046\u306e\u304c\u4e00\u822c\u7684\u3067\u3042\u308b<\/li>\n\n\n\n<li>\u7279\u306b\u30db\u30eb\u30e0\u30a2\u30eb\u30c7\u30d2\u30c9\u3092\u6dfb\u52a0\u3057\u305f\u5909\u6027\u30b2\u30eb\u306e\u5834\u5408\u3001\u30b2\u30eb\u306e\u4f5c\u6210\u3084\u96fb\u6c17\u6cf3\u52d5\u3092\u30c9\u30e9\u30d5\u30c8\u30c1\u30e3\u30f3\u30d0\u30fc\u5185\u3067\u884c\u3046\u5fc5\u8981\u304c\u3042\u308b<\/li>\n\n\n\n<li>RNase\u306b\u3088\u308b\u5206\u89e3\u306b\u6ce8\u610f\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b<\/li>\n<\/ul>\n\n\n\n<p>\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u6613\u7684\u306aRNA\u96fb\u6c17\u6cf3\u52d5\u30d7\u30ed\u30c8\u30b3\u30eb\u3068\u3001\u305d\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u4f5c\u6210\u306e\u53c2\u8003\u306b\u3057\u305f\u691c\u8a0e\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u975e\u5e38\u306b\u7c21\u5358\u306a\u65b9\u6cd5\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u304b\u3089\u64ae\u5f71\u307e\u3067\u7d0430\u5206\u3067\u884c\u3048\u307e\u3059\u3002\u307e\u305f\u3001\u672c\u30b2\u30eb\u306f\u5909\u6027\u30b2\u30eb\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u4ee5\u4e0b\u306e\u7528\u9014\u3067\u3057\u305f\u3089\u5341\u5206\u304a\u52e7\u3081\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Total RNA\u62bd\u51fa\u5f8c\u306e\u30c1\u30a7\u30c3\u30af\uff08\u3068\u308c\u3066\u3044\u308b\u304b\u3001\u660e\u3089\u304b\u306a\u5206\u89e3\u304c\u8d77\u3053\u3063\u3066\u3044\u306a\u3044\u304b\uff09<\/li>\n\n\n\n<li><em>in vitro<\/em>\u8ee2\u5199RNA\u306e\u30c1\u30a7\u30c3\u30af\uff08\u305d\u308c\u3089\u3057\u3044\u30b5\u30a4\u30ba\u306eRNA\u304c\u3067\u304d\u3066\u3044\u308b\u304b\u3001\u660e\u3089\u304b\u306a\u5206\u89e3\u304c\u8d77\u3053\u3063\u3066\u3044\u306a\u3044\u304b\uff09<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-e-gel-ex-agarose-gels\u3092\u7528\u3044\u305f\u7c21\u5358rna\u96fb\u6c17\u6cf3\u52d5\u30d7\u30ed\u30c8\u30b3\u30eb\">E-Gel EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5\u30d7\u30ed\u30c8\u30b3\u30eb<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u4e3b\u306a\u4f7f\u7528\u88fd\u54c1\">\u4e3b\u306a\u4f7f\u7528\u88fd\u54c1<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30b2\u30eb-\u4f7f\u7528\u3067\u304d\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u305f\u3082\u306e\"><span style=\"text-decoration: underline\">\u30b2\u30eb\uff08\u4f7f\u7528\u3067\u304d\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u305f\u3082\u306e\uff09<\/span><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/G401001?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">G401001 Invitrogen\u2122 E-Gel\u2122 EX Agarose Gels, 1%<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/G401002?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">G401002 Invitrogen\u2122 E-Gel\u2122 EX Agarose Gels, 2%<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size\">\uff08\u6ce8\u610f\uff09E-Gel\u306b\u306fSYBR\u2122 Gold II\u8272\u7d20\u3092\u6dfb\u52a0\u3057\u305fE-Gel EX\u30b2\u30eb\uff08\u4e0a\u8a18\uff09\u306e\u4ed6\u306b\u3001SYBR\u2122 Safe\u8272\u7d20\u3092\u6dfb\u52a0\u3057\u305f\u30b2\u30eb\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u305d\u308c\u3089\u306b\u3064\u3044\u3066\u306f\u672c\u7528\u9014\u3067\u306e\u4f7f\u7528\u3092\u304a\u52e7\u3081\u3067\u304d\u307e\u305b\u3093\uff08\u6dfb\u52a0\u8272\u7d20\u306e\u611f\u5ea6\u304c\u4f4e\u3044\u305f\u3081RNA\u96fb\u6c17\u6cf3\u52d5\u306b\u306f\u5411\u304d\u307e\u305b\u3093\u3002\uff09\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u96fb\u6c17\u6cf3\u52d5\u304a\u3088\u3073\u64ae\u5f71\u88c5\u7f6e\"><span style=\"text-decoration: underline\">\u96fb\u6c17\u6cf3\u52d5\u304a\u3088\u3073\u64ae\u5f71\u88c5\u7f6e<\/span><\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/G8300?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">G8300 Invitrogen\u2122 E-Gel\u2122 Power Snap Electrophoresis System<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/G9311?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">G9311 Invitrogen\u2122 E-Gel\u2122 Power Snap Plus Electrophoresis Systems with 1-year Standard Warranty<\/a><\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size\">\uff08\u6ce8\u610f\uff09\u8ca9\u58f2\u3092\u7d42\u4e86\u3057\u305fInvitrogen\u2122 E-GelTM iBaseTM Power System\u3082\u4f7f\u7528\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-rna\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc-\u4f7f\u7528\u3067\u304d\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u305f\u3082\u306e\"><span style=\"text-decoration: underline\">RNA\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\uff08\u4f7f\u7528\u3067\u304d\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u305f\u3082\u306e\uff09<\/span><\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM7150?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">AM7150 Invitrogen\u2122 Millennium\u2122 RNA Markers<\/a>\uff1a0.5\u30011\u30011.5\u30012\u30012.5\u30013\u30014\u30015\u30016\u30019 k\u30d9\u30fc\u30b9\u306e10\u672c\u306e\u30d0\u30f3\u30c9\u3092\u542b\u3080\uff080.5\uff5e1 \u00b5g\u7a0b\u5ea6\/\u30a6\u30a7\u30eb\uff09<\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AM7145?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">AM7145 Invitrogen\u2122 Century\u2122-Plus RNA Markers<\/a>\uff1a100\u3001200\u3001300\u3001400\u3001500\u3001750\u30011,000\u30d9\u30fc\u30b9\u306e7\u672c\u306e\u30d0\u30f3\u30c9\u3092\u542b\u3080\uff081\uff5e2 \u00b5g\u7a0b\u5ea6\/\u30a6\u30a7\u30eb\uff09<\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/SM1821?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">SM1821 RiboRuler High Range RNA Ladder<\/a>\uff1a200\u3001500\u30011,000\u30011,500\u30012,000\u30013,000\u30014,000\u30016,000\u30d9\u30fc\u30b9\u306e8\u672c\u306e\u30d0\u30f3\u30c9\u3092\u542b\u3080\uff081 \u00b5g\u7a0b\u5ea6\/\u30a6\u30a7\u30eb\uff09<\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/SM1831?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">SM1831 RiboRuler Low Range RNA Ladder<\/a>\uff1a100\u3001200\u3001300\u3001400\u3001600\u3001800\u30011,000\u30d9\u30fc\u30b9\u306e7\u672c\u306e\u30d0\u30f3\u30c9\u3092\u542b\u3080\uff081 \u00b5g\u7a0b\u5ea6\/\u30a6\u30a7\u30eb\uff09<\/li>\n<\/ol>\n\n\n\n<p class=\"has-small-font-size\">\uff08\u6ce8\u610f\uff09\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\uff0b\u71b1\u51e6\u7406\u3092\u884c\u308f\u308c\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u71b1\u51e6\u7406\u306f\u4e0a\u8a181. \u30682. \u3067\u306f\u5fc5\u9808\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u30d7\u30ed\u30c8\u30b3\u30eb\">\u30d7\u30ed\u30c8\u30b3\u30eb<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd-\u5909\u6027\u51e6\u7406\"><span style=\"text-decoration: underline\">\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\uff08\u5909\u6027\u51e6\u7406\uff09<\/span><\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>RNA\u30b5\u30f3\u30d7\u30eb\u3092\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30d5\u30ea\u30fc\u6c34\u306710 \u00b5L\u306b\u306a\u308b\u3088\u3046\u306b\u5e0c\u91c8<\/li>\n\n\n\n<li>10 \u00b5L\u306e\u30db\u30eb\u30e0\u30a2\u30df\u30c9\uff08&gt;99%\u3001\u7d42\u6fc3\u5ea6\u7d0450%\uff09\u3092\u6dfb\u52a0\u3057\u3066\u30c8\u30fc\u30bf\u30eb20 \u00b5L\u3068\u3059\u308b<\/li>\n\n\n\n<li>70\u2103\u306710\u5206\u9593\u52a0\u6e29\u3057\u305f\u5f8c\u6c37\u4e0a\u3067\u51b7\u5374<\/li>\n<\/ol>\n\n\n\n<p class=\"has-small-font-size\">\uff08\u6ce8\u610f\uff09\u30b5\u30f3\u30d7\u30eb\u91cf\u306b\u95a2\u3057\u3066\uff1aTotal RNA\u306f100\uff5e500 ng\/\u30a6\u30a7\u30eb\u7a0b\u5ea6\uff0828S\u30fb18S\u306e\u30d0\u30f3\u30c9\u3092\u78ba\u8a8d\u3055\u308c\u308b\u969b\u306f100\uff5e250 ng\u7a0b\u5ea6\u30015.8S\u30fb5S\u306e\u30d0\u30f3\u30c9\u3082\u78ba\u8a8d\u3055\u308c\u305f\u3044\u5834\u5408\u306f250\uff5e500 ng\u7a0b\u5ea6\uff09\u3001<em>in vitro<\/em>\u8ee2\u5199RNA\u306a\u3069\u307b\u307c\u5358\u4e00\u306eRNA\u65ad\u7247\u306e\u5834\u5408\u306f50\uff5e100 ng\u7a0b\u5ea6\u304c\u9069\u91cf\u3067\u3059\u3002<br>\uff08\u6ce8\u610f\uff09\u4e0a\u8a18\u5909\u6027\u51e6\u7406\u306f\u5fc5\u9808\u3067\u306f\u306a\u304f\u30b5\u30f3\u30d7\u30eb\u306e\u7a2e\u985e\u30fb\u89e3\u6790\u76ee\u7684\u306b\u3088\u3063\u3066\u306f\u30b9\u30ad\u30c3\u30d7\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001\u5909\u6027\u51e6\u7406\u306b\u3088\u308b\u60aa\u5f71\u97ff\u306f\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u306e\u3067\u5168\u3066\u306e\u30b1\u30fc\u30b9\u3067\u884c\u308f\u308c\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u30ea\u30dc\u30be\u30fc\u30de\u30ebRNA\uff08rRNA\uff09\u306e\u5b58\u5728\u3092\u78ba\u8a8d\u3059\u308b\u76ee\u7684\u3067\u3042\u308c\u3070\u3001\u5909\u6027\u51e6\u7406\u306a\u3057\u3042\u308b\u3044\u306f\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u306e\u307f\uff08\u71b1\u51e6\u7406\u306a\u3057\uff09\u3067\u3082\u901a\u5e38\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002<br>\uff08\u6ce8\u610f\uff09\u4ed6\u306e\u5909\u6027\u5264\uff08\u30b0\u30ea\u30aa\u30ad\u30b5\u30fc\u30eb\u3001\u30db\u30eb\u30e0\u30a2\u30eb\u30c7\u30d2\u30c9\u3001\u5c3f\u7d20\uff09\u306b\u3064\u3044\u3066\u306f\u6709\u52b9\u6027\u304c\u78ba\u8a8d\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u96fb\u6c17\u6cf3\u52d5\"><span style=\"text-decoration: underline\">\u96fb\u6c17\u6cf3\u52d5<\/span><\/h4>\n\n\n\n<p>\u30b2\u30eb\uff08E-Gel EX Agarose Gels 1%\u3042\u308b\u3044\u306f2%\uff09\u306e\u5404\u30a6\u30a7\u30eb\u306b20 \u00b5L\u30b5\u30f3\u30d7\u30eb\u3092\u30a2\u30d7\u30e9\u30a4\u3057\u6a19\u6e96\u30d7\u30ed\u30c8\u30b3\u30eb\u3067\u96fb\u6c17\u6cf3\u52d5\uff0810\u5206\uff5e12\u5206\u7a0b\u5ea6\uff09<\/p>\n\n\n\n<p class=\"has-small-font-size\">\uff08\u6ce8\u610f\uff09\u30b2\u30eb\u306e\u5168\u30a6\u30a7\u30eb\u306b\u30b5\u30f3\u30d7\u30eb\u3001\u3042\u308b\u3044\u306f\u30cc\u30af\u30ec\u30a2\u30fc\u30bc\u30d5\u30ea\u30fc\u6c34\u7b49\u309220 \u00b5L\u30a2\u30d7\u30e9\u30a4\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br>\uff08\u6ce8\u610f\uff09rRNA\u306e28S\u30fb18S\u306e\u307f\u78ba\u8a8d\u3055\u308c\u305f\u3044\u5834\u5408\u306f1%\u30b2\u30eb\u304c\u304a\u52e7\u3081\u3067\u3059\u30025.8S\u30fb5S\u306e\u30d0\u30f3\u30c9\u3082\u78ba\u8a8d\u3055\u308c\u305f\u3044\u5834\u5408\u306f2%\u30b2\u30eb\u304c\u304a\u52e7\u3081\u3067\u3059\u3002<br>\uff08\u6ce8\u610f\uff09\u96fb\u6c17\u6cf3\u52d5\u5f8c\u6570\u5206\u9593\u5ba4\u6e29\u3067\u30b2\u30eb\u3092\u653e\u7f6e\u3059\u308b\u3068\u691c\u51fa\u611f\u5ea6\u304c\u4e0a\u304c\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<br>\uff08\u6ce8\u610f\uff09\u6cf3\u52d5\u5f8c\u30b2\u30eb\u3092\u6025\u51b7\u3001\u3042\u308b\u3044\u306f\u9577\u6642\u9593\u653e\u7f6e\u3059\u308b\u3068\u30b2\u30eb\u4e2d\u306e\u6ce1\u306e\u767a\u751f\u304c\u9855\u8457\u306b\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u30c7\u30fc\u30bf\u96c6\">\u53c2\u8003\u30c7\u30fc\u30bf\u96c6<\/h2>\n\n\n\n<p>\u4ee5\u4e0b2\u3064\u306e\u8cc7\u6599\u3092\u53c2\u8003\u306b\u4e0a\u8a18\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u4f5c\u6210\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u8a18\u4e8b\uff1a<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets%2FBID%2FApplication-Notes%2Foptimization-rna-electrophoresis-egel-ex-agarose-gels-app-note.pdf?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">Optimization of an RNA electrophoresis workflow for E-Gel EX agarose gels<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/LSG\/manuals\/MAN0017050_egel_powersnapsystem_UG.pdf?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u88fd\u54c1\u30de\u30cb\u30e5\u30a2\u30eb<\/a><\/li>\n<\/ol>\n\n\n\n<p>\u7279\u306b\u3054\u53c2\u8003\u306b\u306a\u308a\u305d\u3046\u306a\u691c\u8a0e\u30c7\u30fc\u30bf\u3092\u4e0a\u8a18\u8a18\u4e8b\u304b\u3089\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-rna\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\u306e\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u306e\u691c\u8a0e\">RNA\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\u306e\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u306e\u691c\u8a0e<\/h3>\n\n\n\n<p>\u4ee5\u4e0b2\u7a2e\u306e\u30de\u30fc\u30ab\u30fc\u3092\u4f7f\u3063\u3066\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u3092\u691c\u8a0e\u3057\u305f\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff08\u56f31\uff09\u3002<br>Millennium RNA Markers\uff08\u56f31. A\uff09\u3001Century-Plus RNA Markers\uff08\u56f31. B\uff09<br>\u7dcfRNA\u91cf\u306f0.5\u30012\u30014 \u00b5g\u306e3\u901a\u308a\u3001\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u306e\u6709\u7121\u3001\u71b1\u51e6\u7406\u306e\u6709\u7121\u306b\u3064\u3044\u3066\u6cf3\u52d5\u7d50\u679c\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"651\" height=\"333\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/964799790001ed542cc3c3c34773ce24.png\" alt=\"\" class=\"wp-image-23997\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/964799790001ed542cc3c3c34773ce24.png 651w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/964799790001ed542cc3c3c34773ce24-300x153.png 300w\" sizes=\"auto, (max-width: 651px) 100vw, 651px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><strong>\u56f31. RNA\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\u306e\u96fb\u6c17\u6cf3\u52d5\u7d50\u679c<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\">A: Millenium RNA Markers\uff08E-Gel EX 1%\u30b2\u30eb\uff09\u3001B\uff1aCentury-Plus RNA Markers\uff08E-Gel EX 2%\u30b2\u30eb\uff09\u3002RNA\u91cf\u306f0.5\u30012\u30014 \u00b5g\u306e3\u30d1\u30bf\u30fc\u30f3\u3001\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u306f\u6dfb\u52a0\u30fb\u672a\u6dfb\u52a0\uff08\uff0b\u30fb\uff0d\uff09\u306e2\u30d1\u30bf\u30fc\u30f3\u3001\u71b1\u51e6\u7406\u3042\u308a\u30fb\u71b1\u51e6\u7406\u306a\u3057\uff08\uff0b\u30fb\uff0d\uff09\u306e2\u30d1\u30bf\u30fc\u30f3\u306b\u3064\u3044\u3066\u8a66\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306b\u3064\u3044\u3066\u8a66\u3057\u305f\u4e2d\u3067\u6700\u9069\u3068\u601d\u308f\u308c\u308b\u7d50\u679c\u3092\u8d64\u67a0\u3067\u56f2\u3063\u305f\u3002*\uff1a\u30b4\u30fc\u30b9\u30c8\u30d0\u30f3\u30c9\uff08RNA\u306e2\u6b21\u69cb\u9020\u5f62\u6210\u306b\u3088\u308a\u51fa\u73fe\u3057\u305f\u3068\u601d\u308f\u308c\u308b\u30d0\u30f3\u30c9\uff09\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u5909\u6027\u51e6\u7406\u306b\u3064\u3044\u3066\"><span style=\"text-decoration: underline\">\u5909\u6027\u51e6\u7406\u306b\u3064\u3044\u3066<\/span><\/h4>\n\n\n\n<p>\u5909\u6027\u51e6\u7406\u3092\u884c\u308f\u306a\u3044\u3068\u3001\u30b9\u30e1\u30a2\u3084\u30b4\u30fc\u30b9\u30c8\u30d0\u30f3\u30c9\u304c\u898b\u3089\u308c\u307e\u3057\u305f\uff08\u4f8b\uff1a\u30b9\u30e1\u30a2\u306fA\u306e\u30ec\u30fc\u30f32\u304a\u3088\u30735\u3001\u30b4\u30fc\u30b9\u30c8\u30d0\u30f3\u30c9\u306fB\u306e\u30ec\u30fc\u30f33\u304a\u3088\u30738\u306e\uff0a\u3067\u793a\u3057\u305f\u30d0\u30f3\u30c9\uff09\u3002\u3053\u308c\u3089\u306e\u554f\u984c\u306f\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u3092\u6dfb\u52a0\u3059\u308b\u3053\u3068\u3067\u89e3\u6d88\u3055\u308c\u307e\u3057\u305f\uff08\u4f8b\uff1aA\u306e\u30ec\u30fc\u30f31\u3001B\u306e\u30ec\u30fc\u30f31\uff09\u3002\u4e00\u65b9\u3001\u71b1\u51e6\u7406\u3060\u3051\u3067\u306f\u5b8c\u5168\u306b\u306f\u89e3\u6d88\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\uff08\u4f8b\uff1aB\u306e\u30ec\u30fc\u30f37\u300110\uff09\u3002\u306a\u304a\u3001\u4eca\u56de\u8a66\u3057\u305f\u4e21\u30de\u30fc\u30ab\u30fc\u3067\u306f\u3001\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u5f8c\u306e\u71b1\u51e6\u7406\u3067\u5927\u304d\u306a\u5909\u5316\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u304c\uff08\u4f8b\uff1aA\u306e\u30ec\u30fc\u30f31\u30683\uff09\u3001RiboRuler High Range RNA Ladder\u304a\u3088\u3073RiboRuler Low Range RNA Ladder\u3067\u306f\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u51e6\u7406\u5f8c\u3067\u3082\u30b4\u30fc\u30b9\u30c8\u30d0\u30f3\u30c9\u304c\u307f\u3089\u308c\u3001\u8ffd\u52a0\u306e\u71b1\u51e6\u7406\u306b\u3088\u308a\u6539\u5584\u3055\u308c\u307e\u3057\u305f\uff08\u30c7\u30fc\u30bf\u975e\u63b2\u8f09\uff09\u3002<\/p>\n\n\n\n<p>\u4ee5\u4e0a\u304b\u3089\u3001RNA\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\u306b\u306f\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u304c\u6709\u52b9\u3067\u3042\u308a\u3001\u8ffd\u52a0\u306e\u71b1\u51e6\u7406\u304c\u6709\u52b9\u306a\u30b1\u30fc\u30b9\u3082\u3042\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u305d\u308c\u305e\u308c\u306e\u30de\u30cb\u30e5\u30a2\u30eb\u8a18\u8f09\u306e\u5909\u6027\u30b2\u30eb\u3067\u306e\u6cf3\u52d5\u7d50\u679c\u3068\u6bd4\u8f03\u3057\u3066\u3001\u30d0\u30f3\u30c9\u306e\u6570\u304c\u7570\u306a\u308b\u7b49\u306e\u5927\u304d\u306a\u9055\u3044\u306f\u78ba\u8a8d\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u4ed6\u306eRNA\u30b5\u30a4\u30ba\u30de\u30fc\u30ab\u30fc\u3092\u3054\u4f7f\u7528\u3044\u305f\u3060\u304f\u5834\u5408\u306f\u5ff5\u306e\u305f\u3081\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\uff0b\u71b1\u51e6\u7406\u306e\u6761\u4ef6\u3092\u304a\u8a66\u3057\u3044\u305f\u3060\u304f\u306e\u304c\u304a\u52e7\u3081\u3067\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-rna\u91cf\u306b\u95a2\u3057\u3066\"><span style=\"text-decoration: underline\">RNA\u91cf\u306b\u95a2\u3057\u3066<\/span><\/h4>\n\n\n\n<p>Millennium RNA Markers\u306e\u5834\u5408\u306f\u8a66\u3057\u305f\u4e2d\u30670.5 \u00b5g\u304c\u6700\u3082\u826f\u304f\u30012 \u00b5g\u306f\u5c11\u3057\u904e\u5270\u3067\u3042\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u4e00\u65b9Century-Plus RNA Markers\u306e\u5834\u5408\u306f2 \u00b5g\u304c\u6700\u3082\u826f\u304f\u30010.5 \u00b5g\u3067\u306f\u5c11\u3057\u5c11\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u306a\u304a\u3001\u30d0\u30f3\u30c9\u6bce\u306e\u6b63\u78ba\u306aRNA\u91cf\u306f\u4e0d\u660e\u3067\u3059\u304c\u3001Millennium RNA Markers\u306e\u5834\u5408\u306f10\u672c\u6bd4\u8f03\u7684\u540c\u3058\u5f37\u5ea6\u306e\u30b7\u30b0\u30ca\u30eb\u306e\u30d0\u30f3\u30c9\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u3053\u3068\u304b\u3089\u4e00\u672c\u3042\u305f\u308a50 ng\u7a0b\u5ea6\u304c\u9069\u91cf\u3060\u3068\u4e88\u6e2c\u3055\u308c\u307e\u3057\u305f\uff080.5 \u00b5g\/10 = 50 ng\u3068\u3044\u3046\u8a08\u7b97\uff09\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-total-rna\u306e\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u306e\u691c\u8a0e\">Total RNA\u306e\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u306e\u691c\u8a0e<\/h3>\n\n\n\n<p>\u6b21\u306b\u3001universal human reference RNA\uff08UHRR\uff09\u3092\u7528\u3044\u3066total RNA\u306e\u6cf3\u52d5\u6761\u4ef6\u3092\u691c\u8a0e\u3057\u305f\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff08\u56f32\uff09\u3002RNA\u91cf\u304c250\uff5e4,000 ng\u306e10\u30d1\u30bf\u30fc\u30f3\u306b\u306a\u308b\u3088\u3046\u306b\u3057\u30011%\u30682%\u306e\u30b2\u30eb\u306b\u30a2\u30d7\u30e9\u30a4\u3057\u307e\u3057\u305f\u3002\u5909\u6027\u51e6\u7406\u306f\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u306e\u307f\u3067\u71b1\u51e6\u7406\u306f\u884c\u3063\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"567\" height=\"286\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/1ba4998b89a38e94b5ee091f1a52d9fd.png\" alt=\"\" class=\"wp-image-22950\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/1ba4998b89a38e94b5ee091f1a52d9fd.png 567w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/1ba4998b89a38e94b5ee091f1a52d9fd-300x151.png 300w\" sizes=\"auto, (max-width: 567px) 100vw, 567px\" \/><\/figure>\n\n\n\n<p><strong>\u56f32. UHRR\u306e\u96fb\u6c17\u6cf3\u52d5\u7d50\u679c<\/strong><\/p>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\">A: E-Gel EX 1%\u30b2\u30eb\u3001B\uff1a E-Gel EX 2%\u30b2\u30eb\u3002RNA\u304c250\uff5e4,000 ng\u306b\u306a\u308b\u3088\u3046\u306b\u305d\u308c\u305e\u308c\u306e\u30b2\u30eb\u306b\u30a2\u30d7\u30e9\u30a4\u3057\u305f\u3002\u5168\u3066\u306b\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u3092\u6dfb\u52a0\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306b\u3064\u3044\u3066\u8a66\u3057\u305f\u4e2d\u3067\u6700\u9069\u3068\u601d\u308f\u308c\u308b\u7d50\u679c\u3092\u8d64\u67a0\u3067\u56f2\u3063\u305f\u3002A\u306eM\uff1aMillennium RNA Markers\u3092250 ng\u3001B\u306eM\uff1aCentury-Plus RNA Markers\u3092500 ng\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>28S\u306818S\u306e\u30d0\u30f3\u30c9\u3092\u78ba\u8a8d\u3059\u308b\u5834\u5408\u306f1%\u30b2\u30eb\u306b250 ng\u7a0b\u5ea6\u306eTotal RNA\u3092\u6d41\u3059\u306e\u304c\u826f\u3055\u305d\u3046\u3067\u3059\u3002\u307e\u305f\u30015.8S\u30015S\u306e\u30d0\u30f3\u30c9\u3082\u78ba\u8a8d\u3055\u308c\u305f\u3044\u5834\u5408\u306f2%\u30b2\u30eb\u306b250\uff5e500 ng\u7a0b\u5ea6\u6d41\u3059\u306e\u304c\u826f\u3055\u305d\u3046\u3067\u3059\u3002\u306a\u304a\u3001\u5c11\u306a\u304f\u3068\u3082rRNA\u306e\u30d0\u30f3\u30c9\u3092\u78ba\u8a8d\u3059\u308b\u4e8b\u304c\u76ee\u7684\u3067\u3042\u308c\u3070\u3001\u5909\u6027\u51e6\u7406\u306f\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u306e\u307f\u3067\u5341\u5206\u305d\u3046\u3067\u3059\u3002\u306a\u304a\u3001\u30c7\u30fc\u30bf\u306f\u793a\u3057\u307e\u305b\u3093\u304c\u3001\u5909\u6027\u51e6\u7406\u306a\u3057\uff08\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u3082\u306a\u3057\uff09\u3067\u3082\u8ffd\u52a0\u306e\u71b1\u51e6\u7406\u3092\u884c\u3063\u3066\u3082\u7d50\u679c\u306f\u307b\u3068\u3093\u3069\u5909\u308f\u308a\u307e\u305b\u3093\u3002rRNA\u306e\u7c21\u6613\u7684\u306a\u30c1\u30a7\u30c3\u30af\u304c\u76ee\u7684\u3067\u3042\u308c\u3070\u305d\u306e\u307e\u307e\u5909\u6027\u51e6\u7406\u306a\u3057\u3067\u6d41\u3057\u3066\u3082\u554f\u984c\u7121\u3055\u305d\u3046\u3067\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-rna\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306e\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u306e\u691c\u8a0e\">RNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306e\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u306e\u691c\u8a0e<\/h3>\n\n\n\n<p>\u6700\u5f8c\u306b\u3001<em>in vitro<\/em>\u8ee2\u5199\u3067\u5408\u6210\u3057\u305fRNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306e\u96fb\u6c17\u6cf3\u52d5\u6761\u4ef6\u3092\u691c\u8a0e\u3057\u305f\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\uff08\u56f33\uff09\u3002\u30b5\u30a4\u30ba\u306e\u7570\u306a\u308b4\u7a2e\u306eRNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\uff08868\u30011,017\u30012,716\u30014,525\u30d9\u30fc\u30b9\u306e4\u7a2e\u985e\uff09\u30921%\u30b2\u30eb\u306b\u6d41\u3057\u307e\u3057\u305f\u3002\u5909\u6027\u51e6\u7406\u306f\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u51e6\u7406\u3057\u305f\u3082\u306e\uff08\u56f33. A\uff09\u3068\u3001\u305d\u306e\u5f8c\u306b\u71b1\u51e6\u7406\u3082\u884c\u3063\u305f\u3082\u306e\uff08\u56f33. B\uff09\u306e2\u901a\u308a\u3092\u8a66\u3057\u307e\u3057\u305f\u3002\u5408\u6210\u5f8c\u7c21\u6613\u7cbe\u88fd\u3092\u884c\u3063\u305f\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u3068\u672a\u7cbe\u88fd\u306e\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u4e21\u65b9\u3092\u6d41\u3057\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"567\" height=\"295\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/db508cefef62d3cd7d130339c75b896f.png\" alt=\"\" class=\"wp-image-22955\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/db508cefef62d3cd7d130339c75b896f.png 567w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/db508cefef62d3cd7d130339c75b896f-300x156.png 300w\" sizes=\"auto, (max-width: 567px) 100vw, 567px\" \/><\/figure>\n\n\n\n<p><strong>\u56f33. \u30b5\u30a4\u30ba\u306e\u7570\u306a\u308b4\u7a2e\u306eRNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306e\u96fb\u6c17\u6cf3\u52d5\u7d50\u679c<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\">A: \u71b1\u51e6\u7406\u306a\u3057B\uff1a \u71b1\u51e6\u7406\u3042\u308a\u3002\u5171\u306bE-Gel EX 1%\u30b2\u30eb\u3002RNA\u30d5\u30e9\u30b0\u30e1\u30f3\u30c8\u306e\u30b5\u30a4\u30ba\u306f868\u30011,017\u30012,716\u30014,525\u30d9\u30fc\u30b9\u306e4\u7a2e\u985e\u3002\u5168\u3066100 ng\u3002M\uff1aRiboRuler High Range RNA Ladder\uff081 \u00b5g\uff09\u30019\uff1aMillennium\u2122 RNA Markers\uff081 \u00b5g\uff09\u30021\u30013\u30015\u30017\uff1a\u672a\u7cbe\u88fd\u30b5\u30f3\u30d7\u30eb\u30012\u30014\u30016\u30018\uff1a\u7cbe\u88fd\u30b5\u30f3\u30d7\u30eb\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u6dfb\u52a0\u5f8c\u306b\u71b1\u51e6\u7406\u3092\u884c\u3063\u305f\u5834\u5408\u3001\u30de\u30fc\u30ab\u30fc\u3068\u6bd4\u8f03\u3057\u30664\u7a2e\u3068\u3082\u305d\u308c\u3089\u3057\u3044\u30b5\u30a4\u30ba\u306e\u30d0\u30f3\u30c9\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002E-Gel EX\u30b2\u30eb\u306f\u5909\u6027\u30b2\u30eb\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u524d\u51e6\u7406\u3092\u884c\u3046\u3053\u3068\u306b\u3088\u308a\u3001\u3042\u308b\u7a0b\u5ea6RNA\u306e\u30b5\u30a4\u30ba\u306b\u5fdc\u3058\u305f\u5206\u753b\u304c\u53ef\u80fd\u3060\u3068\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u306a\u304a\u3001\u71b1\u51e6\u7406\u3092\u884c\u308f\u306a\u3044\u5834\u5408\u306f\u884c\u3063\u305f\u5834\u5408\u3068\u6bd4\u3079\u3066\u5168\u4f53\u7684\u306b\u3046\u3059\u304f\u3001\u4e00\u90e8\u30d0\u30f3\u30c9\u306e\u78ba\u8a8d\u304c\u96e3\u3057\u3044\u3082\u306e\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u672a\u7cbe\u88fd\u30b5\u30f3\u30d7\u30eb\u3067\u305d\u306e\u50be\u5411\u304c\u5f37\u3044\u7d50\u679c\u3067\u3057\u305f\u304c\u3001\u305d\u306e\u7406\u7531\u306f\u4e0d\u660e\u3067\u3059\u3002\u914d\u5217\u4f9d\u5b58\u3067\u30d0\u30f3\u30c9\u304c\u3046\u3059\u304f\u306a\u308b\u306e\u304b\u3069\u3046\u304b\u306f\u3063\u304d\u308a\u3057\u307e\u305b\u3093\u304c\u3001\u30db\u30eb\u30e0\u30a2\u30df\u30c9\u51e6\u7406\uff0b\u71b1\u51e6\u7406\u306b\u3088\u308a\u305d\u306e\u554f\u984c\u306f\u89e3\u6d88\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p>E-Gel EX\u30b2\u30eb\u306f\u5909\u6027\u30b2\u30eb\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001DNA\u3060\u3051\u3067\u306a\u304fRNA\u306e\u96fb\u6c17\u6cf3\u52d5\u306b\u3082\u3042\u308b\u7a0b\u5ea6\u4f7f\u3048\u305d\u3046\u306a\u3053\u3068\u304c\u308f\u304b\u3063\u3066\u3044\u305f\u3060\u3051\u305f\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<p>\u3082\u3057Total RNA\u3001<em>in vitro<\/em>\u8ee2\u5199RNA\u306e\u30c1\u30a7\u30c3\u30af\u3092\u96fb\u6c17\u6cf3\u52d5\u3067\u884c\u308f\u308c\u305f\u3044\u5834\u5408\u306f\u3001\u305c\u3072\u4e00\u5ea6\u304a\u8a66\u3057\u304f\u3060\u3055\u3044\u3002\u7d50\u679c\u306e\u3054\u5831\u544a\u3092\u304a\u5f85\u3061\u3057\u3066\u304a\u308a\u307e\u3059\uff01<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-e-gel-power-snap-e-gel-power-snap-plus\u306e\u30c7\u30e2\u4f9d\u983c-\u8a2a\u554f\u4f9d\u983c\u306f\u3053\u3061\u3089\u304b\u3089\">E-Gel Power Snap\u30fb E-Gel Power Snap Plus\u306e\u30c7\u30e2\u4f9d\u983c\u30fb\u8a2a\u554f\u4f9d\u983c\u306f\u3053\u3061\u3089\u304b\u3089<\/h4>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/e-gel-power-snap-system-demo-request-visit.html?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30c7\u30e2\u4f9d\u983c\u30fb\u8a2a\u554f\u4f9d\u983c\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-\u672c\u8a18\u4e8b\u306b\u95a2\u9023\u3059\u308b\u30d6\u30ed\u30b0\u8a18\u4e8b\">\u672c\u8a18\u4e8b\u306b\u95a2\u9023\u3059\u308b\u30d6\u30ed\u30b0\u8a18\u4e8b<\/h4>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/e-gel_mb_bid_ts_1\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u4fbf\u5229\u3059\u304e\u3066\u7656\u306b\u306a\u308b\u96fb\u6c17\u6cf3\u52d5\u30b7\u30b9\u30c6\u30e0\uff5e\u601d\u3044\u7acb\u3063\u3066\u304b\u308920\u5206\u3067\u64ae\u5f71\u5b8c\u4e86<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/agarose_gel_electrophoresis_workshop_bid_ts_1\/?CID=bid_mol_r04_jp_cp0000_pjt0000_bid00000_0so_blg_nucleic_acid_purification_in_vitro_transcription_bid_ts_mbr_25055_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u3067DNA\u304c\u5206\u96e2\u3057\u3066\u3044\u304f\u52d5\u753b\u3092\u64ae\u5f71\u3057\u3066\u307f\u305f<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a2\u30ac\u30ed\u30fc\u30b9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u6cd5\u306f\u3001PCR\u7523\u7269\u3084\u5236\u9650\u9175\u7d20\u6d88\u5316\u65ad\u7247\u306a\u3069\u4e8c\u672c\u9396DNA\u306e\u89e3\u6790\u306b\u4f7f\u3048\u308b\u7c21\u5358\u3067\u4fbf\u5229\u306a\u65b9\u6cd5\u3067\u3059\u3002\u3053\u306e\u6280\u8853\u306fRNA\u306e\u6cf3\u52d5\u306b\u3082\u4f7f\u3048\u307e\u3059\u304c\u3001\u4ee5\u4e0b\u306a\u3069\u306e\u7406\u7531\u3067DNA\u3068\u6bd4\u3079\u3066\u624b\u9593\u304c\u304b\u304b\u308a\u307e\u3059\u3002 \u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001E-Gel<\/p>\n","protected":false},"author":975,"featured_media":22928,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[225,77],"division":[],"class_list":{"0":"post-22926","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-in-vitro-transcription","9":"tag-nucleic-acid-purification","10":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"RNA\u96fb\u6c17\u6cf3\u52d5\u3092\u7c21\u5358\u30fb\u8fc5\u901f\u306b\u884c\u3046E-Gel\u2122 EX Agarose Gels\u306e\u6d3b\u7528\u6cd5\u3092\u7d39\u4ecb\u3002\u5f93\u6765\u306e\u624b\u9593\u3092\u7701\u304d\u3001\u308f\u305a\u304b30\u5206\u3067Total RNA\u3084in vitro\u8ee2\u5199RNA\u306e\u54c1\u8cea\u78ba\u8a8d\u304c\u53ef\u80fd\u3067\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5\" \/>\n<meta property=\"og:description\" content=\"RNA\u96fb\u6c17\u6cf3\u52d5\u3092\u7c21\u5358\u30fb\u8fc5\u901f\u306b\u884c\u3046E-Gel\u2122 EX Agarose Gels\u306e\u6d3b\u7528\u6cd5\u3092\u7d39\u4ecb\u3002\u5f93\u6765\u306e\u624b\u9593\u3092\u7701\u304d\u3001\u308f\u305a\u304b30\u5206\u3067Total RNA\u3084in vitro\u8ee2\u5199RNA\u306e\u54c1\u8cea\u78ba\u8a8d\u304c\u53ef\u80fd\u3067\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-09-09T22:37:35+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-05T06:29:59+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png\" \/>\n\t<meta property=\"og:image:width\" content=\"619\" \/>\n\t<meta property=\"og:image:height\" content=\"402\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"14\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5\",\"datePublished\":\"2025-09-09T22:37:35+00:00\",\"dateModified\":\"2025-11-05T06:29:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/\"},\"wordCount\":295,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png\",\"keywords\":[\"in vitro\u8ee2\u5199\",\"\u6838\u9178\u7cbe\u88fd\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/\",\"name\":\"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png\",\"datePublished\":\"2025-09-09T22:37:35+00:00\",\"dateModified\":\"2025-11-05T06:29:59+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"description\":\"RNA\u96fb\u6c17\u6cf3\u52d5\u3092\u7c21\u5358\u30fb\u8fc5\u901f\u306b\u884c\u3046E-Gel\u2122 EX Agarose Gels\u306e\u6d3b\u7528\u6cd5\u3092\u7d39\u4ecb\u3002\u5f93\u6765\u306e\u624b\u9593\u3092\u7701\u304d\u3001\u308f\u305a\u304b30\u5206\u3067Total RNA\u3084in vitro\u8ee2\u5199RNA\u306e\u54c1\u8cea\u78ba\u8a8d\u304c\u53ef\u80fd\u3067\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png\",\"width\":619,\"height\":402},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5 - Learning at the Bench","description":"RNA\u96fb\u6c17\u6cf3\u52d5\u3092\u7c21\u5358\u30fb\u8fc5\u901f\u306b\u884c\u3046E-Gel\u2122 EX Agarose Gels\u306e\u6d3b\u7528\u6cd5\u3092\u7d39\u4ecb\u3002\u5f93\u6765\u306e\u624b\u9593\u3092\u7701\u304d\u3001\u308f\u305a\u304b30\u5206\u3067Total RNA\u3084in vitro\u8ee2\u5199RNA\u306e\u54c1\u8cea\u78ba\u8a8d\u304c\u53ef\u80fd\u3067\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5","og_description":"RNA\u96fb\u6c17\u6cf3\u52d5\u3092\u7c21\u5358\u30fb\u8fc5\u901f\u306b\u884c\u3046E-Gel\u2122 EX Agarose Gels\u306e\u6d3b\u7528\u6cd5\u3092\u7d39\u4ecb\u3002\u5f93\u6765\u306e\u624b\u9593\u3092\u7701\u304d\u3001\u308f\u305a\u304b30\u5206\u3067Total RNA\u3084in vitro\u8ee2\u5199RNA\u306e\u54c1\u8cea\u78ba\u8a8d\u304c\u53ef\u80fd\u3067\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-09-09T22:37:35+00:00","article_modified_time":"2025-11-05T06:29:59+00:00","og_image":[{"width":619,"height":402,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"14\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5","datePublished":"2025-09-09T22:37:35+00:00","dateModified":"2025-11-05T06:29:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/"},"wordCount":295,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png","keywords":["in vitro\u8ee2\u5199","\u6838\u9178\u7cbe\u88fd"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/","name":"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png","datePublished":"2025-09-09T22:37:35+00:00","dateModified":"2025-11-05T06:29:59+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"description":"RNA\u96fb\u6c17\u6cf3\u52d5\u3092\u7c21\u5358\u30fb\u8fc5\u901f\u306b\u884c\u3046E-Gel\u2122 EX Agarose Gels\u306e\u6d3b\u7528\u6cd5\u3092\u7d39\u4ecb\u3002\u5f93\u6765\u306e\u624b\u9593\u3092\u7701\u304d\u3001\u308f\u305a\u304b30\u5206\u3067Total RNA\u3084in vitro\u8ee2\u5199RNA\u306e\u54c1\u8cea\u78ba\u8a8d\u304c\u53ef\u80fd\u3067\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png","width":619,"height":402},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u304a\u5f79\u7acb\u3061\u30d7\u30ed\u30c8\u30b3\u30eb\uff1aInvitrogen\u2122 E-Gel\u2122 EX Agarose Gels\u3092\u7528\u3044\u305f\u7c21\u5358RNA\u96fb\u6c17\u6cf3\u52d5"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":225,"label":"in vitro\u8ee2\u5199"},{"value":77,"label":"\u6838\u9178\u7cbe\u88fd"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png",619,402,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":536,"filter":"raw","meta":[],"cat_ID":156,"category_count":536,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":225,"name":"in vitro\u8ee2\u5199","slug":"in-vitro-transcription","term_group":0,"term_taxonomy_id":225,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":77,"name":"\u6838\u9178\u7cbe\u88fd","slug":"nucleic-acid-purification","term_group":0,"term_taxonomy_id":77,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/nucleic-acid-purification-in-vitro-transcription-bid-ts-mbr-25055_eyecatch.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/22926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=22926"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/22926\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/22928"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=22926"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=22926"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=22926"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=22926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}