{"id":23098,"date":"2025-10-02T15:40:45","date_gmt":"2025-10-02T06:40:45","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=23098"},"modified":"2025-11-04T15:25:39","modified_gmt":"2025-11-04T06:25:39","slug":"cell-culture-cell-culture-basic-bid-ts-mbr-25059","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","title":{"rendered":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4"},"content":{"rendered":"\n<p>\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u3084\u6e96\u5099\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u524d\u56de\u306e\u300c\u305d\u306e3\u300d\u3067\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u88c5\u7f6e\u306f\u63c3\u3044\u307e\u3057\u305f\u3002\u4eca\u56de\u304b\u3089\u6570\u56de\u306b\u5206\u3051\u3066\u6d88\u8017\u54c1\u306b\u3064\u3044\u3066\u53d6\u308a\u4e0a\u3052\u307e\u3059\u3002\u307e\u305a\u306f\u3001\u7d30\u80de\u306e\u6210\u9577\u3068\u7dad\u6301\u306b\u4e0d\u53ef\u6b20\u306a\u57f9\u5730\u306b\u3064\u3044\u3066\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"330\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/2a1601d026bba16b6ebaafde583db461.jpg\" alt=\"\" class=\"wp-image-23101\" style=\"width:580px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/2a1601d026bba16b6ebaafde583db461.jpg 800w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/2a1601d026bba16b6ebaafde583db461-300x124.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/2a1601d026bba16b6ebaafde583db461-768x317.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u57f9\u5730\u306f\u3001\u7d30\u80de\u304c\u5065\u5eb7\u306b\u80b2\u3064\u305f\u3081\u306b\u6700\u9069\u306a\u74b0\u5883\u3092\u63d0\u4f9b\u3059\u308b\u751f\u547d\u7dda\u3067\u3059\u3002\u9069\u5207\u306a\u57f9\u5730\u3092\u9078\u3076\u3053\u3068\u306f\u3001\u7d30\u80de\u57f9\u990a\u306e\u6210\u529f\u3092\u5de6\u53f3\u3059\u308b\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u3067\u306f\u3001\u57f9\u5730\u3068\u3057\u3066\u4f55\u3092\u7528\u610f\u3059\u308c\u3070\u3088\u3044\u306e\u304b\u3001\u3069\u306e\u3088\u3046\u306b\u9078\u3079\u3070\u3088\u3044\u306e\u304b\u3001\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u57f9\u5730-\u3068\u306f\">\u300c\u57f9\u5730\u300d\u3068\u306f\uff1f<\/h2>\n\n\n\n<p>\u57f9\u5730\u3092\u9078\u3076\u524d\u306b\u3001\u7d30\u80de\u57f9\u990a\u306e\u5b9f\u9a13\u3092\u3057\u3066\u3044\u308b\u65b9\u3005\u304c\u8a71\u3059\u300c\u57f9\u5730\u300d\u3068\u306f\u4f55\u3092\u6307\u3057\u3066\u3044\u308b\u306e\u304b\u3001\u78ba\u8a8d\u3057\u307e\u3057\u3087\u3046\u3002\u57f9\u5730\u306b\u306f\u3001\u5927\u304d\u304f\u5206\u3051\u3066\u57fa\u790e\u57f9\u5730\u3068\u5b8c\u5168\u57f9\u5730\u304c\u3042\u308a\u3001\u3069\u3061\u3089\u3092\u6307\u3059\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u57fa\u790e\u57f9\u5730<\/strong>\uff1a\u30a2\u30df\u30ce\u9178\u985e\u3001\u30d3\u30bf\u30df\u30f3\u985e\u3001\u7121\u6a5f\u5869\u985e\u3001\u305d\u306e\u4ed6\u306e\u5316\u5408\u7269\u306a\u3069\u3001\u57fa\u672c\u7684\u306a\u6210\u5206\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u4ee3\u8868\u7684\u306a\u57fa\u790e\u57f9\u5730\u306b\u306f\u3001MEM\uff08Minimum Essential Medium\uff09\u3001DMEM\uff08Dulbecco&#8217;s Modified Eagle Medium\uff09\u3001RPMI \uff08Roswell Park Memorial Institute\uff091640 Medium\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002<br>\u57fa\u790e\u57f9\u5730\u3060\u3051\u3067\u306f\u3001\u591a\u304f\u306e\u7d30\u80de\u682a\u306b\u304a\u3044\u3066\u3001\u5897\u6b96\u3084\u7dad\u6301\u304c\u56f0\u96e3\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u5b8c\u5168\u57f9\u5730<\/strong>\uff1a\u57fa\u790e\u57f9\u5730\u306b\u8840\u6e05\u3084\u305d\u306e\u4ed6\u306e\u6210\u9577\u56e0\u5b50\u3001\u30db\u30eb\u30e2\u30f3\u3001\u8ffd\u52a0\u306e\u6804\u990a\u7d20\u3092\u52a0\u3048\u3001\u7d30\u80de\u304c\u5897\u6b96\u3067\u304d\u308b\u6700\u9069\u306a\u74b0\u5883\u3092\u6574\u3048\u305f\u57f9\u5730\u3092\u6307\u3057\u307e\u3059\u3002<br>\u3064\u307e\u308a\u3001\u7d30\u80de\u306e\u5897\u6b96\u3084\u7dad\u6301\u304c\u3067\u304d\u308bReady-to-use\u306e\u57f9\u5730\u3092\u6307\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p>\u6b74\u53f2\u3042\u308b\u30d6\u30e9\u30f3\u30c9\u306eGibco<sup>TM<\/sup> \u88fd\u54c1\u3067\u306f\u3001\u57fa\u790e\u57f9\u5730\u3092\u8ca9\u58f2\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u5b8c\u5168\u57f9\u5730\uff08\u8840\u6e05\u306a\u3069\u5fc5\u8981\u306a\u6210\u5206\u3092\u52a0\u3048\u305f\u57f9\u5730\uff09\u306f\u8ca9\u58f2\u3057\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p>\u305d\u306e\u305f\u3081\u3001Gibco\u88fd\u54c1\u3067\u7d30\u80de\u57f9\u990a\u3092\u884c\u3046\u5834\u5408\u3001\u57fa\u790e\u57f9\u5730\u306b\u8840\u6e05\u3092\u52a0\u3048\u3066\u5b8c\u5168\u57f9\u5730\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u305f\u3081\u3001\u4e0b\u8a182\u70b9\u304c\u5fc5\u9808\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u57fa\u790e\u57f9\u5730<\/strong><\/li>\n\n\n\n<li><strong>\u8840\u6e05<\/strong><\/li>\n<\/ul>\n\n\n\n<p>\u3053\u308c\u3089\u306b\u52a0\u3048\u3001\u6297\u751f\u7269\u8cea\u3082\u72b6\u6cc1\u306b\u5fdc\u3058\u3066\u6dfb\u52a0\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u7d30\u80de\u57f9\u990a\u3092\u306f\u3058\u3081\u308b\u524d\u306b\u3001<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u57fa\u790e\u57f9\u5730<\/strong><\/li>\n\n\n\n<li><strong>\u8840\u6e05<\/strong><\/li>\n\n\n\n<li><strong>\u6297\u751f\u7269\u8cea<\/strong><\/li>\n<\/ul>\n\n\n\n<p>\u306e3\u30bb\u30c3\u30c8\u3092\u305d\u308d\u3048\u3066\u304a\u304f\u3088\u3046\u306b\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"455\" height=\"340\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/4f93a20f6bbae257035c51712af56db8.jpg\" alt=\"\u57f9\u5730\u306e\u30dc\u30c8\u30eb\" class=\"wp-image-23111\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/4f93a20f6bbae257035c51712af56db8.jpg 455w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/4f93a20f6bbae257035c51712af56db8-300x224.jpg 300w\" sizes=\"auto, (max-width: 455px) 100vw, 455px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u672c\u30d6\u30ed\u30b0\u3067\u306f\u3001\u3053\u308c\u30893\u3064\u306e\u3046\u3061\u300c\u57fa\u790e\u57f9\u5730\u300d\u306b\u30d5\u30a9\u30fc\u30ab\u30b9\u3057\u3001\u8840\u6e05\u3084\u6297\u751f\u7269\u8cea\u306b\u3064\u3044\u3066\u306f\u300c\u305d\u306e5\u300d\u3067\u8a73\u3057\u304f\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u57fa\u790e\u57f9\u5730\u306e\u9078\u3073\u65b9\">\u57fa\u790e\u57f9\u5730\u306e\u9078\u3073\u65b9<\/h2>\n\n\n\n<p>\u7d30\u80de\u306b\u6700\u9069\u306a\u57fa\u790e\u57f9\u5730\u306e\u60c5\u5831\u306f\u3001\u7d30\u80de\u306e\u5165\u624b\u5143\uff08JCRB\u306a\u3069\u306e\u7d30\u80de\u30d0\u30f3\u30af\uff09\u306e\u30c7\u30fc\u30bf\u30b7\u30fc\u30c8\u3084Web\u306a\u3069\u306b\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u60c5\u5831\u306b\u5f93\u3063\u3066\u6e96\u5099\u3092\u6574\u3048\u307e\u3059\u3002\u7d30\u80de\u3092\u8b72\u6e21\u3055\u308c\u308b\u5834\u5408\u3082\u3001\u6700\u9069\u306a\u57fa\u790e\u57f9\u5730\u3092\u8b72\u6e21\u5143\u306b\u5fc5\u305a\u78ba\u8a8d\u3057\u3066\u304a\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p>\u7d30\u80de\u306b\u6700\u9069\u306a\u57fa\u790e\u57f9\u5730\u306e\u60c5\u5831\u306f\u3001\u7d30\u80de\u306e\u5165\u624b\u5143\uff08JCRB\u306a\u3069\u306e\u7d30\u80de\u30d0\u30f3\u30af\uff09\u306e\u30c7\u30fc\u30bf\u30b7\u30fc\u30c8\u3084Web\u306a\u3069\u306b\u63b2\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u60c5\u5831\u306b\u5f93\u3063\u3066\u6e96\u5099\u3092\u6574\u3048\u307e\u3059\u3002\u7d30\u80de\u3092\u8b72\u6e21\u3055\u308c\u308b\u5834\u5408\u3082\u3001\u6700\u9069\u306a\u57fa\u790e\u57f9\u5730\u3092\u8b72\u6e21\u5143\u306b\u5fc5\u305a\u78ba\u8a8d\u3057\u3066\u304a\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p>\u4f8b\uff1a\u7d30\u80de\u8cfc\u5165\u5143\u306e\u300c\u57f9\u5730\u300d\u6b04\u306b\u3001\u300cEagle&#8217;s minimum essential medium \uff08Earle&#8217;s salts, containing L-glutamine\uff09 with non essential amino acids and 10% fetal bovine serum.\u300d\u3068\u8a18\u8f09\u3055\u308c\u3066\u3044\u305f\u3068\u3057\u307e\u3059\u3002 \u3053\u3053\u306b\u306f3\u3064\u306e\u60c5\u5831\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Eagle&#8217;s minimum essential medium \uff08Earle&#8217;s salts, containing L-glutamine\uff09<\/strong>\uff1a\u57fa\u790e\u57f9\u5730\u3068\u3057\u3066\uff08E\uff09MEM\u57f9\u5730\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>with non essential amino acids<\/strong>\uff1a\u975e\u5fc5\u9808\u30a2\u30df\u30ce\u9178\u3092\u542b\u3093\u3067\u3044\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>10% fetal bovine serum<\/strong>\uff1a10%\u306eFBS\uff08\u30a6\u30b7\u80ce\u4ed4\u8840\u6e05\uff09\u3092\u52a0\u3048\u308b\u3053\u3068\u3092\u6307\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p>\u3053\u306e\u3088\u3046\u306b\u3001\u63d0\u4f9b\u3055\u308c\u305f\u60c5\u5831\u3092\u8aad\u307f\u89e3\u304f\u3053\u3068\u3067\u3001\u9069\u5207\u306a\u57f9\u5730\u3084\u5fc5\u8981\u306a\u6d88\u8017\u54c1\u3092\u628a\u63e1\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u3055\u3089\u306b\u3001\u7d30\u80de\u306e\u5165\u624b\u5143\u306b\u306f\u57f9\u5730\u3084\u30b5\u30d7\u30ea\u30e1\u30f3\u30c8\u306e\u30e1\u30fc\u30ab\u30fc\u540d\u3084\u88fd\u54c1\u756a\u53f7\u304c\u66f8\u304b\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u5834\u5408\u3001\u57fa\u672c\u7684\u306b\u306f\u3001\u305d\u306e\u30e1\u30fc\u30ab\u30fc\u306e\u305d\u306e\u88fd\u54c1\u756a\u53f7\u306e\u88fd\u54c1\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u5225\u306e\u30e1\u30fc\u30ab\u30fc\u3084\u88fd\u54c1\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u7d44\u6210\u304c\u540c\u7b49\u304b\u5426\u304b\u3001\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u307e\u305f\u3001\u57f9\u990a\u6761\u4ef6\u3084\u7d99\u4ee3\u65b9\u6cd5\u3001\u7d99\u4ee3\u6642\u7d30\u80de\u6570\u3082\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u57f9\u990a\u3092\u59cb\u3081\u308b\u524d\u306b\u3057\u3063\u304b\u308a\u628a\u63e1\u3057\u3066\u304a\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u57fa\u790e\u57f9\u5730\u306e\u77e5\u8b58\">\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u57fa\u790e\u57f9\u5730\u306e\u77e5\u8b58<\/h2>\n\n\n\n<p>\u524d\u7ae0\u3067\u57fa\u790e\u57f9\u5730\u306e\u9078\u3073\u65b9\u306f\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u57fa\u790e\u57f9\u5730\u306b\u95a2\u3059\u308b\u57fa\u672c\u7684\u306a\u77e5\u8b58\u3092\u6301\u3063\u3066\u304a\u304f\u3053\u3068\u3067\u3001\u4f55\u304b\u56f0\u3063\u305f\u3068\u304d\u3084\u8ff7\u3063\u305f\u3068\u304d\u306b\u67d4\u8edf\u306b\u5bfe\u5fdc\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u30681-\u540c\u3058\u57fa\u790e\u57f9\u5730\u3067\u3082-\u7a2e\u985e\u306f\u591a\u5c90\u306b\u308f\u305f\u308b\">\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u30681\uff1a \u540c\u3058\u57fa\u790e\u57f9\u5730\u3067\u3082\u3001\u7a2e\u985e\u306f\u591a\u5c90\u306b\u308f\u305f\u308b<\/h3>\n\n\n\n<p>\u305f\u3068\u3048\u3070\u3001\u7d30\u80de\u682a\u306e\u5165\u624b\u5143\u306e\u63a8\u5968\u57f9\u5730\u60c5\u5831\u3068\u3057\u3066\u300cDulbecco&#8217;s modified Eagle medium with 10% fetal bovine serum\u300d\u3068\u8a18\u8f09\u304c\u3042\u3063\u305f\u3068\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u300cDMEM\u306b10% FBS\u3092\u52a0\u3048\u305f\u3082\u306e\u300d\u3092\u5b8c\u5168\u57f9\u5730\u3068\u3057\u3066\u4f7f\u3063\u3066\u304f\u3060\u3055\u3044\u3068\u3044\u3046\u610f\u5473\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u300cDMEM\u300d\u300cFBS\u300d\u306e2\u3064\u3092\u7528\u610f\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30e1\u30fc\u30ab\u30fc\u540d\u3084\u88fd\u54c1\u756a\u53f7\u306e\u60c5\u5831\u304c\u306a\u304b\u3063\u305f\u3068\u3057\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u3054\u81ea\u8eab\u3067\u5fc5\u8981\u306a\u6d88\u8017\u54c1\u306e\u88fd\u54c1\u756a\u53f7\u3092\u7279\u5b9a\u3057\u306a\u304f\u3066\u306f\u306a\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p>FBS\u306a\u3069\u306e\u8840\u6e05\u306b\u3064\u3044\u3066\u306f\u300c\u305d\u306e5\u300d\u3067\u8aac\u660e\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u57fa\u790e\u57f9\u5730\u306e\u7279\u5b9a\u306e\u4ed5\u65b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u307e\u305a\u3001<a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/BID\/brochures\/gibco-sku-list-brochure-ja.pdf?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">Gibco<sup>TM<\/sup> \u57fa\u790e\u57f9\u5730<\/a> \u65e9\u898b\u8868\u304b\u3089\u4e0a\u8a18\u4f8b\u306e\u57fa\u790e\u57f9\u5730\u3067\u3042\u308b\u300cDMEM\uff08D-MEM\uff09\u300d\u3092\u63a2\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u88681\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<p class=\"has-text-align-center has-medium-font-size\"><strong>\u88681. Gibco\u57fa\u790e\u57f9\u5730\u65e9\u898b\u8868\u306e\u4e00\u90e8<\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center\" style=\"font-size:15px\">\uff08\u6700\u65b0\u306e\u88fd\u54c1\u30e9\u30a4\u30f3\u30a2\u30c3\u30d7\u306f\u3001\u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u306eWeb\u30b5\u30a4\u30c8\u306b\u3066\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\uff09<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<p class=\"has-text-align-center has-small-font-size\">\u203b\u753b\u50cf\u3092\u30af\u30ea\u30c3\u30af\u3059\u308b\u3068Gibco\u57fa\u790e\u57f9\u5730\u65e9\u898b\u8868\u304cPDF\u3067\u8868\u793a<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/BID\/brochures\/gibco-sku-list-brochure-ja.pdf#page=4?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\" noreferrer noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"346\" height=\"351\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/a7df2c3bfb8b0ad72f731feca05b6798.jpg\" alt=\"\" class=\"wp-image-23119\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/a7df2c3bfb8b0ad72f731feca05b6798.jpg 346w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/a7df2c3bfb8b0ad72f731feca05b6798-296x300.jpg 296w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/a7df2c3bfb8b0ad72f731feca05b6798-80x80.jpg 80w\" sizes=\"auto, (max-width: 346px) 100vw, 346px\" \/><\/a><\/figure>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u5b9f\u306f\u3001\u88681\u306e\u3088\u3046\u306b\u3001\u300cDMEM\u300d\u3060\u3051\u3067\u3082\u305f\u304f\u3055\u3093\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u304c\u5b58\u5728\u3057\u3066\u3044\u308b\u306e\u3067\u3059\u3002\u88681\u306f\u3054\u304f\u4e00\u90e8\u3067\u3059\u304c\u30012025\u5e74\u73fe\u5728\u3001Gibco<sup>TM<\/sup> DMEM\u306b\u306f20\u7a2e\u985e\u4ee5\u4e0a\u3082\u306e\u30e9\u30a4\u30f3\u30a2\u30c3\u30d7\u304c\u5b58\u5728\u3057\u307e\u3059\uff08\u5bb9\u91cf\u9055\u3044\u3092\u9664\u304f\uff09\u3002<\/p>\n\n\n\n<p>\u3057\u304b\u3057\u7d30\u80de\u682a\u306e\u5165\u624b\u5143\u306e\u63a8\u5968\u57f9\u5730\u306b\u306f\u300cDulbecco&#8217;s modified Eagle&#8217;s medium with 10% fetal bovine serum\u300d\u3068\u3057\u304b\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u3067\u306f\u4e00\u4f53\u3001\u3069\u306e\u300cDMEM\u300d\u3092\u8cfc\u5165\u3059\u308c\u3070\u3088\u3044\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<p>\u7b54\u3048\u306f\u3001\u300c\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306a\u7d44\u6210\u306eDMEM\u3092\u8cfc\u5165\u3059\u308b\u300d\u3067\u3059\u3002\u306a\u305c\u306a\u3089\u3070\u3001\u6539\u5909\u3055\u308c\u305f\u57f9\u5730\u304c\u63a8\u5968\u306e\u3068\u304d\u306f\u3001\u305d\u306e\u65e8\u304c\u7d30\u80de\u5143\u306e\u60c5\u5831\u3068\u3057\u3066\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u591a\u3044\u305f\u3081\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u7279\u306b\u4f55\u3082\u8ffd\u8a18\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u306f\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306a\u7d44\u6210\u306e\u57f9\u5730\u3092\u8cfc\u5165\u3059\u308b\u3053\u3068\u304c\u307b\u3068\u3093\u3069\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u3067\u306f\u3001\u6b21\u306e\u7591\u554f\u3067\u3059\u3002\u305a\u3089\u308a\u3068\u4e26\u3093\u3060DMEM\u306e\u3046\u3061\u3001\u3069\u308c\u304c\u300c\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u7d44\u6210\u300d\u306a\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u30682-\u57fa\u790e\u57f9\u5730\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u7d44\u6210\u3092\u628a\u63e1\u3059\u308b\">\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u30682\uff1a \u57fa\u790e\u57f9\u5730\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u7d44\u6210\u3092\u628a\u63e1\u3059\u308b<\/h3>\n\n\n\n<p>\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306e\u7d44\u6210\u306e\u78ba\u8a8d\u306b\u306f\u539f\u8457\u8ad6\u6587\u306e\u53c2\u7167\u304c\u304a\u3059\u3059\u3081\u3067\u3059\u3002\u88682\u306b\u4e3b\u306a\u57f9\u5730\u306e\u3046\u3061\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306a\u7d44\u6210\u306eGibco<sup>TM<\/sup>\u57f9\u5730\u306e\u88fd\u54c1\u756a\u53f7\u306a\u3069\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u305f\u3060\u3001\u300c\u539f\u8457\u8ad6\u6587\u3067\u306f\u3007\u3007\u306e\u7d44\u6210\u304c\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3060\u3051\u308c\u3069\u3001\u5b9f\u969b\u306f\u2715\u2715\u306e\u7d44\u6210\u306e\u3082\u306e\u304c\u3088\u304f\u4f7f\u308f\u308c\u3066\u3044\u308b\u300d\u30b1\u30fc\u30b9\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u306a\u57f9\u5730\u306f\u3001\u5099\u8003\u6b04\u306b\u8a18\u8f09\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center\"><strong>\u88682. \u4e3b\u306a\u57f9\u5730\u306e\u3046\u3061\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306a\u7d44\u6210\u306eGibco\u57f9\u5730\u306e\u88fd\u54c1\u756a\u53f7\u3068\u7d44\u6210<\/strong><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<figure style=\"font-size:13px\" class=\"wp-block-table\">\n  <table class=\"has-fixed-layout\">\n    <colgroup>\n      <col style=\"width: 14%\">\n      <col style=\"width: 20%\">\n      <col style=\"width: 9%\">\n      <col style=\"width: 9%\">\n      <col style=\"width: 10%\">\n      <col style=\"width: 38%\">\n    <\/colgroup>\n    <thead>\n      <tr>\n        <th class=\"has-text-align-center\" data-align=\"center\"><font size=\"2\"><strong>\u57f9\u5730\u306e\u4e00\u822c\u540d<\/strong><\/font><\/th>\n        <th class=\"has-text-align-center\" data-align=\"center\"><font size=\"2\"><strong>\u6b63\u5f0f\u540d\u79f0<\/strong><\/font><\/th>\n        <th class=\"has-text-align-center\" data-align=\"center\"><font size=\"2\"><strong>\u88fd\u54c1\u756a\u53f7<sup>\u203b1<\/sup><\/strong><\/font><\/th>\n        <th class=\"has-text-align-center\" data-align=\"center\"><font size=\"2\"><strong>\u7d44\u6210<br>\u30ea\u30f3\u30af<\/strong><\/font><\/th>\n        <th class=\"has-text-align-center\" data-align=\"center\"><font size=\"2\"><strong>\u539f\u8457\u8ad6\u6587<strong>PMID<\/strong><\/font><\/th>\n        <th class=\"has-text-align-center\" data-align=\"center\"><font size=\"2\"><strong>\u5099\u8003<\/strong><\/font><\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">DMEM<br>\uff08D-MEM\uff09<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Dulbecco\u2019s Modified Eagle Medium<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11885084?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11885<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.48.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/13669362\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">13669362<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">\u539f\u8457\u8ad6\u6587\u306f\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u306e\u305f\u3081\u300111885\u3082\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u88fd\u54c1\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u73fe\u5728\u306f\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\u88fd\u54c1\uff0811965\uff09\u304c\u6bd4\u8f03\u7684\u3088\u304f\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">RPMI1640<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Roswell Park Memorial Institute 1640 Medium<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11875093?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11875<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.114.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/5218782\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">5218782<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">MEM<br>\uff08EMEM\uff09<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">(Eagle&#8217;s ) Minimum Essential Medium<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11095080?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11095<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.92.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/13675766\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">13675766<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">\u03b1MEM<br>\uff08alpha-MEM<br>,MEM\u03b1\uff09<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Minimum Essential Medium Eagle Alpha Modification<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/12571063?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">12571<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.94.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/5279808\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">5279808<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">DMEM\/F-12<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Dulbecco\u2019s Modified Eagle Medium : Nutrient Mixture F-12<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11320033?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11320<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.55.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/6774812\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">6774812<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">\u539f\u8457\u8ad6\u6587\u306e\u57f9\u5730\uff0811320\uff09\u306fHEPES\u4e0d\u542b\u3067\u3059\u304c\u3001\u6804\u990a\u8c4a\u5bcc\u306a\u57f9\u5730\u306e\u305f\u3081\u3001pH\u306e\u5b89\u5b9a\u5316\u3092\u76ee\u7684\u3068\u3057\u3066HEPES\u3092\u52a0\u3048\u305f\u7d44\u6210\u306e\u57f9\u5730\uff0811330\uff09\u3082\u3088\u304f\u4f7f\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">Ham&#8217;s F-10<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Ham\u2019s F-10 Nutrient Mixture<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11550043?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11550<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.61.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/13952250\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">13952250<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">Ham&#8217;s F-12<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Ham\u2019s F-12 Nutrient Mixture<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11765054?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11765<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.64.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/14294058\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">14294058<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">\u539f\u8457\u8ad6\u6587\u306e\u7d44\u6210\u304b\u3089\u6539\u5909\u3055\u308c\u305f\u57f9\u5730\uff0811765\uff09\u304c\u73fe\u5728\u306e\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">IMDM<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Iscove\u2019s Modified Dulbecco\u2019s\u2019 Medium<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/12440046?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">12440<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.76.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/305462\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">305462<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">Medium 199<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">Medium 199<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/jp\/ja\/11150059?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11150<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.86.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/15402504\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">15402504<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><\/td>\n      <\/tr>\n      <tr>\n        <td class=\"has-text-align-center\" data-align=\"center\">McCoy&#8217;s 5A<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">McCoy\u2019s 5A\uff08Modified\uff09Medium<\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/jp\/ja\/16600082?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">16600<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/media-formulation.83.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d44\u6210<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\"><a href=\"https:\/\/pubmed.ncbi.nlm.nih.gov\/13634054\/\" target=\"_blank\" rel=\"noreferrer noopener nofollow\">13634054<\/a><\/td>\n        <td class=\"has-text-align-center\" data-align=\"center\">\u539f\u8457\u8ad6\u6587\u3067\u306fBacto-Peptone\u304c\u4e0d\u542b\u3067\u3059\u304c\u3001\u305d\u306e\u5f8c\u3001\u6a19\u6e96\u7684\u306a\u7d44\u6210\u306bBacto-Peptone\u3092\u542b\u3080\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u300216600\u306fBacto-Peptone\u3092\u542b\u3080\u7d44\u6210\u3067\u3059\u3002<\/td>\n      <\/tr>\n    <\/tbody>\n  <\/table>\n<\/figure>\n\n\n\n<p class=\"has-small-font-size\"><strong>\u203b1 <\/strong>Gibco\u57f9\u5730\u306e\u88fd\u54c1\u756a\u53f7\u306f\u3001\u6570\u5b575\u6841-\u6570\u5b573\u6841\u306e\u8a088\u6841\u3068\u306a\u3063\u3066\u304a\u308a\u3001\u524d\u534a\u306e5\u6841\u304c\u88fd\u54c1\u306e\u7a2e\u985e\u3092\u3001\u5f8c\u534a\u306e3\u6841\u306f\u5bb9\u91cf\u3092\u8868\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u8868\u3067\u306f\u524d\u534a\u306e\u6570\u5b575\u6841\u306e\u307f\u3092\u8868\u8a18\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u88682\u306b\u5f93\u3046\u3068\u3001DMEM\u306e\u3046\u3061\u3001\u30b9\u30bf\u30f3\u30c0\u30fc\u30c9\u306a\u7d44\u6210\u306e\u88fd\u54c1\u306f\u30ab\u30bf\u30ed\u30b0\u5185\u306e\u8d64\u3067\u56f2\u3063\u305f\u57f9\u5730\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"716\" height=\"335\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_4_D-MEM.jpg\" alt=\"\" class=\"wp-image-23148\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_4_D-MEM.jpg 716w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_4_D-MEM-300x140.jpg 300w\" sizes=\"auto, (max-width: 716px) 100vw, 716px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u3064\u307e\u308a\u3001\u8cfc\u5165\u3057\u305f\u7d30\u80de\u306e\u7d30\u80de\u5143\u306b\u3001\u63a8\u5968\u57f9\u5730\u3068\u3057\u3066\u300cDulbecco&#8217;s modified Eagle&#8217;s medium with 10% fetal bovine serum\u300d\u3068\u66f8\u304b\u308c\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u57fa\u790e\u57f9\u5730\u3068\u3057\u3066\u4e0a\u8a18\u8d64\u67a0\u5185\u306e\u88fd\u54c1\u3092\u7528\u610f\u3057\u3001\u305d\u306e\u5f8c\u300110%\u306eFBS\u3092\u52a0\u3048\u3066\u7d30\u80de\u57f9\u990a\u7528\u306e\u5b8c\u5168\u57f9\u5730\u3068\u3057\u3066\u7528\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u306a\u304a\u3001\u88682\u306e\u5099\u8003\u6b04\u306b\u3082\u3042\u308a\u307e\u3059\u304c\u3001DMEM\u306f\u3001\u539f\u8457\u8ad6\u6587\u3067\u306f\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u3067\u3059\u3002\u3057\u304b\u3057\u3001DMEM\u3067\u306f\u3001\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\u3082\u5927\u5909\u3088\u304f\u4f7f\u308f\u308c\u307e\u3059\u3002\u3082\u3057DMEM\u306e\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\u30bf\u30a4\u30d7\u304c\u63a8\u5968\u3055\u308c\u308b\u3068\u304d\u306f\u3001\u7d30\u80de\u682a\u306e\u5165\u624b\u5143\u306e\u60c5\u5831\u306b\u306f\u300cDMEM (high glucose)\u300d\u306e\u3088\u3046\u306b\u3001\u30ab\u30c3\u30b3\u66f8\u304d\u3084with\u3001\uff0b\u3092\u4f7f\u3063\u3066\u66f8\u304b\u308c\u308b\u3053\u3068\u304c\u591a\u3044\u3067\u3059\u3002\u7d30\u80de\u5143\u306e\u60c5\u5831\u3092\u4e00\u5b57\u4e00\u53e5\u9003\u3055\u305a\u3001\u3057\u3063\u304b\u308a\u78ba\u8a8d\u3092\u3057\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p>\u3068\u3053\u308d\u3067\u3001\u63a8\u5968\u57f9\u5730\u3067\u306f\u306a\u3044\u7d44\u6210\u306f\u7d76\u5bfe\u306b\u4f7f\u3063\u3066\u306f\u3044\u3051\u306a\u3044\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u3082\u3061\u308d\u3093\u3001\u305d\u3093\u306a\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308b\u304b\u3089\u3053\u305d\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u3068\u3042\u308b\u6210\u5206\u3060\u3051\u5225\u306e\u6210\u5206\u306b\u5909\u66f4\u3057\u3066\u3044\u308b\u57f9\u5730\u3084\u3001\u3068\u3042\u308b\u6210\u5206\u3060\u3051\u3042\u3048\u3066\u9664\u3044\u3066\u3044\u308b\u57f9\u5730\u3082\u3042\u308a\u307e\u3059\u3002\u3067\u306f\u3001\u3053\u308c\u3089\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u306b\u306f\u3069\u3046\u3044\u3046\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308b\u306e\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u30683-\u305d\u308c\u305e\u308c\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u306e\u610f\u5473\u3068\u30e1\u30ea\u30c3\u30c8\u3092\u7406\u89e3\u3059\u308b\">\u77e5\u3063\u3066\u304a\u304d\u305f\u3044\u3053\u30683\uff1a\u305d\u308c\u305e\u308c\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u306e\u610f\u5473\u3068\u30e1\u30ea\u30c3\u30c8\u3092\u7406\u89e3\u3059\u308b<\/h3>\n\n\n\n<p>\u57f9\u5730\u306e\u30d0\u30ea\u30a8\u30fc\u30b7\u30e7\u30f3\u3067\u3088\u304f\u767b\u5834\u3059\u308b\u9805\u76ee\u306b\u3064\u3044\u3066\u3001\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u3068\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\">\u30fb\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u3068\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9<\/h4>\n\n\n\n<p>\u30b0\u30eb\u30b3\u30fc\u30b9\u306f\u7d30\u80de\u306e\u4e3b\u8981\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u6e90\u3067\u3059\u3002DMEM\u306b\u306f\u3001\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u30bf\u30a4\u30d7\u3068\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\u30bf\u30a4\u30d7\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u306f1,000 mg\/L\u3001\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\u306f4,500 mg\/L\u3067\u3001DMEM\u306e\u6a19\u6e96\u7d44\u6210\u306f\u300c\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u300d\u30bf\u30a4\u30d7\u3067\u3059\u304c\u3001\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\u30bf\u30a4\u30d7\u3082\u983b\u7e41\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p>\u9ad8\u30b0\u30eb\u30b3\u30fc\u30b9\u30bf\u30a4\u30d7\u306f\u3001\u30d2\u30c8\u306e\u304c\u3093\u7d30\u80de\u306e\u57f9\u990a\u3067\u3088\u304f\u4f7f\u308f\u308c\u307e\u3059\u3002\u304c\u3093\u7d30\u80de\u3067\u306f\u89e3\u7cd6\u7cfb\u306e\u4ee3\u8b1d\u304c\u6d3b\u767a\u306a\u305f\u3081\u3001\u30b0\u30eb\u30b3\u30fc\u30b9\u6fc3\u5ea6\u3092\u9ad8\u3081\u308b\u3053\u3068\u3067\u5897\u6b96\u304c\u4fc3\u9032\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3067\u3059\u3002<br>\u4f4e\u30b0\u30eb\u30b3\u30fc\u30b9\u30bf\u30a4\u30d7\u306f\u3001\u7d30\u80de\u306e\u4ee3\u8b1d\u304c\u65e9\u304f\u3001\u4ee3\u8b1d\u306e\u30b9\u30d4\u30fc\u30c9\u3092\u4e0b\u3052\u305f\u3044\u5834\u5408\u3001\u5206\u5316\u8a98\u5c0e\u6642\u3001\u9577\u671f\u57f9\u990a\u6642\u306a\u3069\u306b\u4f7f\u308f\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-l-\u30b0\u30eb\u30bf\u30df\u30f3\">\u30fbL-\u30b0\u30eb\u30bf\u30df\u30f3<\/h4>\n\n\n\n<p>L-\u30b0\u30eb\u30bf\u30df\u30f3\u306fTCA\u56de\u8def\u306b\u5165\u3063\u3066ATP\u306e\u7523\u751f\u306b\u95a2\u4e0e\u3059\u308b\u3001\u57f9\u5730\u306b\u306f\u6b20\u304b\u305b\u306a\u3044\u6210\u5206\u3067\u3059\u3002\u6b20\u304b\u305b\u306a\u3044\u306b\u3082\u95a2\u308f\u3089\u305a\u3001\u3053\u308c\u304c\u542b\u307e\u308c\u3066\u3044\u306a\u3044\u57f9\u5730\u304c\u5b58\u5728\u3059\u308b\u7406\u7531\u306f\u3001L-\u30b0\u30eb\u30bf\u30df\u30f3\u304c\u5c11\u3005\u4e0d\u5b89\u5b9a\u306a\u7269\u8cea\u306e\u305f\u3081\u3067\u3059\u300237 \u2103\u3067\u5206\u89e3\u3057\u3066\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u30a4\u30aa\u30f3\u3092\u767a\u751f\u3055\u305b\u3001\u7d30\u80de\u6bd2\u6027\u306e\u539f\u56e0\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001L-\u30b0\u30eb\u30bf\u30df\u30f3\u304c\u542b\u307e\u308c\u3066\u3044\u306a\u3044\u57f9\u5730\u3092\u8cfc\u5165\u3057\u3001\u7121\u83cc\u7684\u306b\u5f8c\u304b\u3089L-\u30b0\u30eb\u30bf\u30df\u30f3\u3092\u52a0\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002L-\u30b0\u30eb\u30bf\u30df\u30f3\u306e\u5358\u54c1\u8ca9\u58f2\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/25030081?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a>\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p>\u3057\u304b\u3057\u3001\u5f8c\u304b\u3089\u7121\u83cc\u7684\u306b\u52a0\u3048\u308b\u306e\u306f\u3084\u306f\u308a\u9762\u5012\u3067\u3059\u3002\u305d\u3053\u3067\u3001\u300cL-\u30b0\u30eb\u30bf\u30df\u30f3\u3068\u540c\u3058\u50cd\u304d\u3092\u3057\u3066\u3001\u304b\u3064\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u30a4\u30aa\u30f3\u306e\u7523\u751f\u3092\u4f4e\u6e1b\u3055\u305b\u308b\u300d\u3082\u306e\u304cL-\u30b0\u30eb\u30bf\u30df\u30f3\u306e\u4ee3\u308f\u308a\u306b\u4f7f\u308f\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u308c\u304cGibco\u2122 GlutaMAX\u2122 Supplement\u3067\u3059\u3002\u3042\u3089\u304b\u3058\u3081GlutaMax Supplement\u304c\u6dfb\u52a0\u3055\u308c\u305f\u57f9\u5730\uff08\u30ea\u30b9\u30c8\u306f<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/BID\/brochures\/glutamax-product-brochure.pdf?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a>\uff09\u3082\u3042\u308c\u3070\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/35050079?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u5358\u54c1\u8ca9\u58f2<\/a>\u3082\u3042\u308a\u307e\u3059\u3002\u3088\u308a\u7d30\u80de\u6bd2\u6027\u306b\u654f\u611f\u306a\u7d30\u80de\u3084\u3001\u9577\u671f\u57f9\u990a\u306e\u5834\u5408\u306b\u304a\u3059\u3059\u3081\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-\u30d5\u30a7\u30ce\u30fc\u30eb\u30ec\u30c3\u30c9\">\u30fb\u30d5\u30a7\u30ce\u30fc\u30eb\u30ec\u30c3\u30c9<\/h4>\n\n\n\n<p>\u57f9\u5730\u3068\u8a00\u3048\u3070\u3001\u8d64\u3044\u8272\u306e\u6db2\u4f53\u3067\u3059\u3002\u3042\u306e\u8d64\u306f\u30d5\u30a7\u30ce\u30fc\u30eb\u30ec\u30c3\u30c9\u306e\u8272\u3067\u3001pH\u306b\u3088\u3063\u3066\u8272\u304c\u5909\u308f\u308a\u307e\u3059\u3002\u4e2d\u6027\uff08pH 7\uff5e8\uff09\u3060\u3068\u8d64\u8272\u3001\u9178\u6027\uff08pH 6\u4ee5\u4e0b\uff09\u3060\u3068\u9ec4\u8272\u3001\u30a2\u30eb\u30ab\u30ea\u6027\uff08pH 8\u4ee5\u4e0a\uff09\u3060\u3068\u30d4\u30f3\u30af\uff5e\u7d2b\u8272\u306b\u306a\u308a\u307e\u3059\u306e\u3067\u3001\u57f9\u5730\u306e\u72b6\u614b\u3092\u76ee\u8996\u3067\u3059\u3050\u306b\u898b\u6975\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"724\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/6d67e560fbd245af105c5de5f3ac269a-scaled.jpg\" alt=\"\" class=\"wp-image-23266\" style=\"width:633px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/6d67e560fbd245af105c5de5f3ac269a-scaled.jpg 2560w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/6d67e560fbd245af105c5de5f3ac269a-300x85.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/6d67e560fbd245af105c5de5f3ac269a-1024x290.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/6d67e560fbd245af105c5de5f3ac269a-768x217.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/6d67e560fbd245af105c5de5f3ac269a-1536x434.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/6d67e560fbd245af105c5de5f3ac269a-2048x579.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><strong>\u56f31. pH\u306b\u3088\u308b\u30d5\u30a7\u30ce\u30fc\u30eb\u30ec\u30c3\u30c9\u306e\u8272\u306e\u5909\u5316\u30a4\u30e1\u30fc\u30b8<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u3057\u304b\u3057\u3001\u30d5\u30a7\u30ce\u30fc\u30eb\u30ec\u30c3\u30c9\u306f\u86cd\u5149\u3092\u767a\u3057\u307e\u3059\u306e\u3067\u3001\u57f9\u5730\u4e2d\u306e\u7d30\u80de\u306e\u86cd\u5149\u89b3\u5bdf\u3092\u884c\u3046\u3068\u304d\u306b\u306f\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u3092\u4e0a\u3052\u3066\u3057\u307e\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u86cd\u5149\u691c\u51fa\u6642\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u8efd\u6e1b\u3055\u305b\u308b\u305f\u3081\u306b\u4e0d\u542b\u306e\u57f9\u5730\u3092\u4f7f\u3046\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0\">\u30fb\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0<\/h4>\n\n\n\n<p>\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0\u306f\u57f9\u5730\u306b\u5fc5\u9808\u306e\u6210\u5206\u3067\u3001\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u4e2d\u306eCO<sub>2<\/sub>\u3068\u5e73\u8861\u3092\u4fdd\u3064\u3053\u3068\u3067\u3001\u57f9\u5730\u4e2dpH\u3092\u5b89\u5b9a\u5316\u3055\u305b\u308b\u5f79\u5272\u3092\u62c5\u3063\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u52a0\u71b1\u306b\u3088\u308a\u975e\u5e38\u306b\u5206\u89e3\u3057\u3084\u3059\u3044\u7269\u8cea\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u8abf\u88fd\u5f8c\u306b\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d6\u6ec5\u83cc\u3092\u3059\u308b\u3053\u3068\u306e\u3042\u308b\u7c89\u672b\u57f9\u5730\u306b\u306f\u305f\u3044\u3066\u3044\u542b\u307e\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u30d5\u30a3\u30eb\u30bf\u30fc\u6ec5\u83cc\u306e\u3068\u304d\u306f\u6ec5\u83cc\u524d\u306b\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0\u3092\u52a0\u3048\u3066\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d6\u6ec5\u83cc\u3092\u3059\u308b\u3068\u304d\u306f\u3001\u6ec5\u83cc\u5f8c\u306b\u7121\u83cc\u7684\u306b\u52a0\u3048\u3066\u304f\u3060\u3055\u3044\u3002\u5358\u54c1\u8ca9\u58f2\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/25080094?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a>\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-hepes\">\u30fbHEPES<\/h4>\n\n\n\n<p>HEPES\u306f\u751f\u5316\u5b66\u5b9f\u9a13\u3067\u306f\u304a\u306a\u3058\u307f\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u3067\u3059\u304c\u3001\u7d30\u80de\u57f9\u990a\u306b\u304a\u3044\u3066\u3082\u3001pH\u3092\u5b89\u5b9a\u5316\u3055\u305b\u308b\u305f\u3081\u306b\u4f7f\u308f\u308c\u307e\u3059\u3002 \u7d30\u80de\u57f9\u990a\u306b\u304a\u3044\u3066\u3001pH\u306e\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u306b\u306fCO<sub>2<\/sub>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u3068\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0\u304c\u91cd\u8981\u306a\u5f79\u5272\u3092\u62c5\u3063\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u305f\u3068\u3048\u3070\u3001\u7d30\u80de\u3092CO<sub>2<\/sub>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u306e\u5916\u306b\u51fa\u3057\u3066\u9577\u6642\u9593\u306e\u4f5c\u696d\u3092\u3057\u3066\u3044\u308b\u3068\u3001\u91cd\u70ad\u9178\u30a4\u30aa\u30f3\u3068CO<sub>2<\/sub>\u306e\u30d0\u30e9\u30f3\u30b9\u304c\u5d29\u308c\u3066\u57f9\u5730\u304c\u30a2\u30eb\u30ab\u30ea\u6027\u306b\u50be\u304f\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u70ad\u9178\u6c34\u7d20\u30ca\u30c8\u30ea\u30a6\u30e0\u3088\u308a\u3082\u7de9\u885d\u80fd\u529b\u306e\u9ad8\u3044HEPES\u3092\u52a0\u3048\u308b\u3053\u3068\u3067\u3001CO<sub>2<\/sub>\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u5916\u3067\u306e\u4f5c\u696d\u3067\u3082pH\u304c\u5b89\u5b9a\u5316\u3057\u3084\u3059\u304f\u306a\u308b\u3068\u3044\u3046\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002HEPES\u306e\u5358\u54c1\u8ca9\u58f2\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/jp\/ja\/15630130?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a>\u3067\u3059\u3002<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<h4 class=\"wp-block-heading\" id=\"h-\u30d4\u30eb\u30d3\u30f3\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\">\u30fb\u30d4\u30eb\u30d3\u30f3\u9178\u30ca\u30c8\u30ea\u30a6\u30e0<\/h4>\n\n\n\n<p>\u30d4\u30eb\u30d3\u30f3\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\u306f\u70ad\u7d20\u6e90\u306e\u3072\u3068\u3064\u3067\u3042\u308a\u3001\u7d30\u80de\u306e\u89e3\u7cd6\u7d4c\u8def\u306e\u4e2d\u9593\u4ee3\u8b1d\u7269\u3068\u3057\u3066\u7523\u751f\u3055\u308c\u308b\u305f\u3081\u3001\u7d30\u80de\u57f9\u990a\u306b\u5fc5\u9808\u3067\u306f\u306a\u3044\u3068\u3082\u8a00\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u7d30\u80de\u306e\u5897\u6b96\u3084\u4ee3\u8b1d\u3092\u30b5\u30dd\u30fc\u30c8\u3059\u308b\u305f\u3081\u306b\u542b\u307e\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3092\u542b\u307e\u306a\u3044\u57f9\u5730\u3082\u5e02\u8ca9\u3055\u308c\u3066\u304a\u308a\u3001\u5f8c\u304b\u3089\u52a0\u3048\u308b\u305f\u3081\u306e<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11360070?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u5358\u54c1\u8ca9\u58f2<\/a>\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u975e\u5fc5\u9808\u30a2\u30df\u30ce\u9178-non-essential-amino-acids-neaa\">\u30fb\u975e\u5fc5\u9808\u30a2\u30df\u30ce\u9178\uff08non-essential amino acids\u3001NEAA\uff09<\/h4>\n\n\n\n<p>\u975e\u5fc5\u9808\u30a2\u30df\u30ce\u9178\u306f\u3001Glycine\u3001L-Alanine\u3001L-Asparagine\u3001L-Aspartic acid\u3001L-Glutamic Acid\u3001L-Proline\u3001L-Serine\u306e\u3053\u3068\u3067\u3001\u3053\u308c\u3089\u306e\u30a2\u30df\u30ce\u9178\u306f\u4f53\u5185\u3067\u5408\u6210\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u300c\u975e\u5fc5\u9808\u300d\u3068\u547c\u3070\u308c\u307e\u3059\u3002\u5897\u6b96\u306e\u901f\u3044\u7d30\u80de\u306e\u5834\u5408\u306b\u6dfb\u52a0\u304c\u63a8\u5968\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306f\u975e\u5fc5\u9808\u30a2\u30df\u30ce\u9178\u3092\u7523\u751f\u3057\u307e\u3059\u304c\u3001\u5897\u6b96\u304c\u901f\u3044\u3068\u4e0d\u8db3\u3059\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3067\u3059\u3002\u5358\u54c1\u8ca9\u58f2\u306f<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11140050?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a>\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u53c2\u8003\u30d6\u30ed\u30b0\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-environment-2-bid-ts\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u610f\u5916\u3068\u77e5\u3089\u306a\u3044\u57fa\u790e\u57f9\u5730\u306e\u4e16\u754c<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-stem-cell-bid-ts-mbr-24019\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u5b9a\u756a\u4e2d\u306e\u5b9a\u756a\uff01\u57fa\u790e\u57f9\u5730DMEM\u3068\u4ef2\u9593\u305f\u3061<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-history-2-bid-ts-6\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u57fa\u790e\u57f9\u5730\u306e\u958b\u767a\u3068\u682a\u7d30\u80de\u306e\u8a95\u751f\u306e\u6df1\u3044\u95a2\u4fc2<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u57fa\u790e\u57f9\u5730\u3092\u5b8c\u5168\u57f9\u5730\u306b\u3059\u308b\">\u57fa\u790e\u57f9\u5730\u3092\u5b8c\u5168\u57f9\u5730\u306b\u3059\u308b<\/h2>\n\n\n\n<p>\u6700\u5f8c\u306b\u3001\u5c11\u3057\u3060\u3051\u5b9f\u8df5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u3087\u3046\u3002\u57fa\u790e\u57f9\u5730\u306bFBS\u3068\u6297\u751f\u7269\u8cea\u3092\u52a0\u3048\u3001\u5b8c\u5168\u57f9\u5730\u3068\u3059\u308b\u305f\u3081\u306e\u65b9\u6cd5\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u5b8c\u5168\u57f9\u5730\uff08\u57fa\u790e\u57f9\u5730\uff0b10% FBS\uff0b\u6297\u751f\u7269\u8cea\uff09\u306e\u4e00\u822c\u7684\u306a\u8abf\u88fd\u65b9\u6cd5\uff1a<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u51b7\u51cd\u4fdd\u5b58\u3057\u3066\u3044\u305fFBS\u3084\u6297\u751f\u7269\u8cea\u3092\u89e3\u51cd\u3057\u307e\u3059\u3002<br>\u51b7\u8535\u5eab\u3067\u4e00\u6669\u7f6e\u3044\u3066\u304a\u304d\u3001\u3086\u3063\u304f\u308a\u3068\u89e3\u51cd\u3059\u308b\u3053\u3068\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\u3002<br>\u6025\u304e\u306e\u5834\u5408\u306f\u5e38\u6e29\u3067\u306e\u89e3\u51cd\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001\u5fc5\u8981\u4ee5\u4e0a\u306b\u6e29\u3081\u306a\u3044\u3088\u3046\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br><\/li>\n\n\n\n<li>500 mL\u306e\u57f9\u5730\u3092\u4f7f\u3046\u5834\u5408\u3001500 mL\u306e\u57f9\u5730\u30dc\u30c8\u30eb\u306b50 mL\u306eFBS\u3068\u3001\u898f\u5b9a\u91cf\u306e\u6297\u751f\u7269\u8cea\u3092\u7121\u83cc\u7684\u306b\u52a0\u3048\u3001\u3088\u304f\u6df7\u5408\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p>\u3053\u3053\u3067\u3001\u7d42\u6fc3\u5ea610%\u3068\u3059\u308b\u306e\u306a\u3089\u3001\u672c\u6765\u306f450 mL\u306e\u57f9\u5730\u306b50 mL\u306eFBS\u3092\u52a0\u3048\u307e\u3059\u304c\u3001\u6163\u4f8b\u7684\u306b\u3001500 mL\u306e\u30dc\u30c8\u30eb\u306b\u76f4\u63a5\u52a0\u3048\u308b\u3053\u3068\u3082\u3088\u304f\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u8abf\u88fd\u3057\u305f\u5b8c\u5168\u57f9\u5730\u306f\u3001\u51b7\u8535\u5eab\u3067\u4fdd\u7ba1\u3057\u3001\u3067\u304d\u308b\u3060\u3051\u65e9\u3081\u306b\u4f7f\u3044\u5207\u308a\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p>\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u3067\u6210\u679c\u3092\u51fa\u3059\u306b\u3042\u305f\u3063\u3066\u3001\u9069\u5207\u306a\u57f9\u5730\u3092\u9078\u3076\u3053\u3068\u306f\u975e\u5e38\u306b\u5927\u5207\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u7d30\u80de\u306f\u3057\u3083\u3079\u308c\u307e\u305b\u3093\u304c\u3001\u751f\u304d\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7d30\u80de\u305f\u3061\u304c\u3069\u3046\u3044\u3046\u6027\u8cea\u3092\u6301\u3063\u3066\u3044\u3066\u3069\u3046\u3044\u3063\u305f\u57f9\u5730\u3092\u597d\u307f\u3001\u3069\u3046\u3044\u3046\u6804\u990a\u5206\u304c\u5fc5\u9808\u306a\u306e\u304b\u3001\u79c1\u305f\u3061\u304c\u3057\u3063\u304b\u308a\u628a\u63e1\u3057\u3001\u6700\u9069\u306a\u74b0\u5883\u3092\u63d0\u4f9b\u3057\u3066\u3042\u3052\u308b\u3053\u3068\u304c\u5927\u5207\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u6b21\u56de\u306f\u3001\u8840\u6e05\u3084\u6297\u751f\u7269\u8cea\u306b\u3064\u3044\u3066\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u7d30\u80de\u57f9\u990a\u306e\u7406\u89e3\u3092\u6df1\u3081\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u30b7\u30ea\u30fc\u30ba\u305d\u306e\u4ed6\u306e\u8a18\u4e8b\u306f\u3053\u3061\u3089\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25031\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d30\u80de\u57f9\u990a\u306e\u57fa\u790e\u3068\u30dd\u30a4\u30f3\u30c8\uff5e\u305d\u306e1\uff1a\u8a2d\u5099\u306e\u6e96\u5099<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25044\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d30\u80de\u57f9\u990a\u306e\u57fa\u790e\u3068\u30dd\u30a4\u30f3\u30c8\uff5e\u305d\u306e2\uff1a\u57f9\u5730\u306e\u6e96\u5099<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25051\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d30\u80de\u57f9\u990a\u306e\u57fa\u790e\u3068\u30dd\u30a4\u30f3\u30c8\uff5e\u305d\u306e3\uff1a\u89b3\u5bdf\u3068\u4fdd\u5b58\u306b\u5fc5\u8981\u306a\u88c5\u7f6e<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u3082\u3063\u3068\u5b66\u3073\u305f\u3044\u4eba\u5411\u3051\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-stem-cell-bid-ts-mbr-24038\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d30\u80de\u57f9\u990a\u95a2\u9023\u306e\u5b66\u7fd2\u30ea\u30bd\u30fc\u30b9\u307e\u3068\u3081\uff5e\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30fb\u30bb\u30df\u30ca\u30fc\u30fb\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u306a\u3069\uff5e<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-gibco-tm-\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9-\u30d5\u30a9\u30fc\u30e0\">Gibco<sup>TM<\/sup> \u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\uff08\u30d5\u30a9\u30fc\u30e0\uff09<\/h4>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_culture_basic_bid_ts_mbr_25059_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u300c\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9\u300d\u306f\u3001\u7d30\u80de\u57f9\u990a\u306b\u521d\u3081\u3066\u6311\u6226\u3055\u308c\u308b\u65b9\u3084\u3001\u307e\u3060\u7d4c\u9a13\u306e\u6d45\u3044\u65b9\u306b\u5411\u3051\u3066\u3001\u57fa\u790e\u77e5\u8b58\u3084\u6e96\u5099\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002 \u524d\u56de\u306e\u300c\u305d\u306e3\u300d\u3067\u3001\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u88c5\u7f6e\u306f\u63c3\u3044\u307e\u3057\u305f\u3002\u4eca\u56de\u304b\u3089\u6570\u56de\u306b\u5206\u3051\u3066\u6d88\u8017\u54c1\u306b<\/p>\n","protected":false},"author":975,"featured_media":23100,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[23,239],"division":[],"class_list":{"0":"post-23098","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell","8":"tag-cell-culture","9":"tag-cell-culture-basic","10":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u7d30\u80de\u306e\u6210\u9577\u3068\u7dad\u6301\u306b\u4e0d\u53ef\u6b20\u306a\u57f9\u5730\u306e\u91cd\u8981\u6027\u3068\u9078\u3073\u65b9\u3092\u89e3\u8aac\u3059\u308b\u3001\u7d30\u80de\u57f9\u990a\u521d\u5fc3\u8005\u5411\u3051\u30ac\u30a4\u30c9\u306e\u7b2c4\u56de\u3002\u9069\u5207\u306a\u57f9\u5730\u9078\u629e\u304c\u5b9f\u9a13\u6210\u529f\u306e\u9375\u3068\u306a\u308b\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u60c5\u5831\u3067\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4\" \/>\n<meta property=\"og:description\" content=\"\u7d30\u80de\u306e\u6210\u9577\u3068\u7dad\u6301\u306b\u4e0d\u53ef\u6b20\u306a\u57f9\u5730\u306e\u91cd\u8981\u6027\u3068\u9078\u3073\u65b9\u3092\u89e3\u8aac\u3059\u308b\u3001\u7d30\u80de\u57f9\u990a\u521d\u5fc3\u8005\u5411\u3051\u30ac\u30a4\u30c9\u306e\u7b2c4\u56de\u3002\u9069\u5207\u306a\u57f9\u5730\u9078\u629e\u304c\u5b9f\u9a13\u6210\u529f\u306e\u9375\u3068\u306a\u308b\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u60c5\u5831\u3067\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-10-02T06:40:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-04T06:25:39+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"330\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"20\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4\",\"datePublished\":\"2025-10-02T06:40:45+00:00\",\"dateModified\":\"2025-11-04T06:25:39+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/\"},\"wordCount\":267,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg\",\"keywords\":[\"\u7d30\u80de\u57f9\u990a\",\"\u7d30\u80de\u57f9\u990a\u306e\u57fa\u790e\u3068\u6e96\u5099\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/\",\"name\":\"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg\",\"datePublished\":\"2025-10-02T06:40:45+00:00\",\"dateModified\":\"2025-11-04T06:25:39+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"description\":\"\u7d30\u80de\u306e\u6210\u9577\u3068\u7dad\u6301\u306b\u4e0d\u53ef\u6b20\u306a\u57f9\u5730\u306e\u91cd\u8981\u6027\u3068\u9078\u3073\u65b9\u3092\u89e3\u8aac\u3059\u308b\u3001\u7d30\u80de\u57f9\u990a\u521d\u5fc3\u8005\u5411\u3051\u30ac\u30a4\u30c9\u306e\u7b2c4\u56de\u3002\u9069\u5207\u306a\u57f9\u5730\u9078\u629e\u304c\u5b9f\u9a13\u6210\u529f\u306e\u9375\u3068\u306a\u308b\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u60c5\u5831\u3067\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/09\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg\",\"width\":800,\"height\":330},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4 - Learning at the Bench","description":"\u7d30\u80de\u306e\u6210\u9577\u3068\u7dad\u6301\u306b\u4e0d\u53ef\u6b20\u306a\u57f9\u5730\u306e\u91cd\u8981\u6027\u3068\u9078\u3073\u65b9\u3092\u89e3\u8aac\u3059\u308b\u3001\u7d30\u80de\u57f9\u990a\u521d\u5fc3\u8005\u5411\u3051\u30ac\u30a4\u30c9\u306e\u7b2c4\u56de\u3002\u9069\u5207\u306a\u57f9\u5730\u9078\u629e\u304c\u5b9f\u9a13\u6210\u529f\u306e\u9375\u3068\u306a\u308b\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u60c5\u5831\u3067\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","og_locale":"ja_JP","og_type":"article","og_title":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","og_description":"\u7d30\u80de\u306e\u6210\u9577\u3068\u7dad\u6301\u306b\u4e0d\u53ef\u6b20\u306a\u57f9\u5730\u306e\u91cd\u8981\u6027\u3068\u9078\u3073\u65b9\u3092\u89e3\u8aac\u3059\u308b\u3001\u7d30\u80de\u57f9\u990a\u521d\u5fc3\u8005\u5411\u3051\u30ac\u30a4\u30c9\u306e\u7b2c4\u56de\u3002\u9069\u5207\u306a\u57f9\u5730\u9078\u629e\u304c\u5b9f\u9a13\u6210\u529f\u306e\u9375\u3068\u306a\u308b\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u60c5\u5831\u3067\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-10-02T06:40:45+00:00","article_modified_time":"2025-11-04T06:25:39+00:00","og_image":[{"width":800,"height":330,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"20\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4","datePublished":"2025-10-02T06:40:45+00:00","dateModified":"2025-11-04T06:25:39+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/"},"wordCount":267,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg","keywords":["\u7d30\u80de\u57f9\u990a","\u7d30\u80de\u57f9\u990a\u306e\u57fa\u790e\u3068\u6e96\u5099"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/","name":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg","datePublished":"2025-10-02T06:40:45+00:00","dateModified":"2025-11-04T06:25:39+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"description":"\u7d30\u80de\u306e\u6210\u9577\u3068\u7dad\u6301\u306b\u4e0d\u53ef\u6b20\u306a\u57f9\u5730\u306e\u91cd\u8981\u6027\u3068\u9078\u3073\u65b9\u3092\u89e3\u8aac\u3059\u308b\u3001\u7d30\u80de\u57f9\u990a\u521d\u5fc3\u8005\u5411\u3051\u30ac\u30a4\u30c9\u306e\u7b2c4\u56de\u3002\u9069\u5207\u306a\u57f9\u5730\u9078\u629e\u304c\u5b9f\u9a13\u6210\u529f\u306e\u9375\u3068\u306a\u308b\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u60c5\u5831\u3067\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg","width":800,"height":330},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-culture-basic-bid-ts-mbr-25059\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u7d30\u80de\u57f9\u990a\u7528\u306e\u57f9\u5730\uff5e\u521d\u5fc3\u8005\u5fc5\u898b\uff01\u7d30\u80de\u57f9\u990a\u306e\u5b8c\u5168\u30b5\u30dd\u30fc\u30c8\u30ac\u30a4\u30c9 \u305d\u306e4"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":23,"label":"\u7d30\u80de\u57f9\u990a"},{"value":239,"label":"\u7d30\u80de\u57f9\u990a\u306e\u57fa\u790e\u3068\u6e96\u5099"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg",760,314,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":63,"filter":"raw","meta":[]},{"term_id":239,"name":"\u7d30\u80de\u57f9\u990a\u306e\u57fa\u790e\u3068\u6e96\u5099","slug":"cell-culture-basic","term_group":0,"term_taxonomy_id":239,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/cell-culture-cell-culture-basic-bid-ts-mbr-25059_eycatch.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/23098","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=23098"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/23098\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/23100"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=23098"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=23098"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=23098"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=23098"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}