{"id":236,"date":"2016-01-13T00:00:00","date_gmt":"2016-01-13T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/"},"modified":"2025-10-16T18:23:42","modified_gmt":"2025-10-16T09:23:42","slug":"qpcr-basic21","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/","title":{"rendered":"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306f\u30e6\u30cb\u30d0\u30fc\u30b5\u30eb\u306aPCR\u6761\u4ef6\u306e\u5229\u70b9\u3092\u30d5\u30eb\u306b\u751f\u304b\u3057\u305f384\u30a6\u30a7\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306e\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u3001\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/pcr\/real-time-pcr\/real-time-pcr-assays\/taqman-gene-expression\/real-time-pcr-taqman-arrays.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr22_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">TaqMan\u00ae Array Card<\/a>\u300d\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-taqman-array-card\u3068\u306f\">TaqMan\u00ae Array Card\u3068\u306f\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">TaqMan\u00ae Array Card\u306f\u3001\u30d2\u30c8\u3001\u30de\u30a6\u30b9\u3001\u30e9\u30c3\u30c8\u30674\u4e07\u7a2e\u985e\u3092\u8d85\u3048\u308bTaqMan\u00ae Gene Expression Assays, Inventoried\u304b\u3089\u76ee\u7684\u306e\u30a2\u30c3\u30bb\u30a4\u3092\u9078\u629e\u3057\u3001\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306b\u5f93\u3063\u3066\u30ab\u30fc\u30c9\u3092\u4f5c\u6210\u3067\u304d\u308b\u30c4\u30fc\u30eb\u3067\u3059\u3002<strong>\u6700\u5927\u3067380\u3082\u306e\u907a\u4f1d\u5b50\u30921\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u4e0a\u3067\u7db2\u7f85\u7684\u306b\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3001TaqMan\u00ae\u30b1\u30df\u30b9\u30c8\u30ea\u3092\u63a1\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u4fe1\u983c\u3067\u304d\u308b\u9ad8\u3044\u5b9a\u91cf\u6027\u3082\u62c5\u4fdd\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u307e\u3067\u306e\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u3067\u306f\u3001\u7db2\u7f85\u6027\u304b\u5b9a\u91cf\u6027\u3001\u305d\u306e\u3069\u3061\u3089\u304b\u3092\u72a0\u7272\u306b\u305b\u3056\u308b\u3092\u5f97\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u6280\u8853\u3092\u5fdc\u7528\u3057\u3001<strong>\u76f8\u53cd\u3059\u308b\u4e8c\u3064\u306e\u30cb\u30fc\u30ba\u3092\u6e80\u305f\u3057\u305f\u753b\u671f\u7684\u306a\u65b9\u6cd5\u3001\u305d\u308c\u304cTaqMan\u00ae Card<\/strong>\u306a\u306e\u3067\u3059\u3002TaqMan\u00ae Card\u3092\u4f7f\u7528\u3057\u305f\u6587\u732e\u304c\u7d9a\u3005\u3068\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">TaqMan\u00ae Array Card\u306f\u3001\u73fe\u5728\u5229\u7528\u3067\u304d\u308b\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306e\u4e2d\u3067\u306f\u3001<strong>\u6700\u3082\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\u6027\u3092\u6709\u3059\u308b\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u3068\u3044\u3048\u308b<\/strong>\u3067\u3057\u3087\u3046\u3002&#8221;Time-to-Results&#8221;\u3001\u3059\u306a\u308f\u3061\u7814\u7a76\u6210\u679c\u3092\u5f97\u308b\u307e\u3067\u306b\u8981\u3059\u308b\u6642\u9593\u3092\u3044\u304b\u306b\u77ed\u7e2e\u3059\u308b\u304b\u3002\u6700\u8fd1\u306f\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u53cd\u5fdc\u6642\u9593\u3092\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u6ce8\u76ee\u3055\u308c\u3001\u5404\u793e\u304b\u3089\u3055\u307e\u3056\u307e\u306a\u6a5f\u68b0\u3084\u8a66\u85ac\u304c\u8ca9\u58f2\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u305d\u308c\u3089\u306e\u88fd\u54c1\u3092\u624b\u3063\u53d6\u308a\u65e9\u304f\u7528\u3044\u308c\u3070\u5b9f\u9a13\u7d50\u679c\u3092\u77ed\u7e2e\u3067\u304d\u308b\u3068\u306f\u9650\u308a\u307e\u305b\u3093\u3002\u907a\u4f1d\u5b50\u767a\u73fe\u89e3\u6790\u7814\u7a76\u306b\u3068\u3063\u3066\u3001\u771f\u306e\u30b9\u30d4\u30fc\u30c9\u30a2\u30c3\u30d7\u306b\u5fc5\u8981\u306a\u3053\u3068\u306f\u4f55\u304b\u3001\u3053\u308c\u307e\u3067\u306e\u56de\u3067\u89e3\u8aac\u3057\u307e\u3057\u305f\u3002\u3054\u7d39\u4ecb\u3057\u305f\u4fbf\u5229\u306a\u30c4\u30fc\u30eb\u3092\u5229\u7528\u3044\u305f\u3060\u304f\u3053\u3068\u3067\u3001\u3053\u308c\u307e\u3067\u5b9f\u9a13\u306b\u8981\u3057\u3066\u3044\u305f\u6642\u9593\u3092\u30c7\u30fc\u30bf\u306e\u8003\u5bdf\u3084\u4ed6\u306e\u5b9f\u9a13\u306b\u304a\u4f7f\u3044\u3044\u305f\u3060\u3051\u305f\u3089\u5e78\u3044\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u3055\u306b\u3001\u9032\u5316\u3057\u7d9a\u3051\u308b\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR \u3067\u3059\u306d\u3002\u6b21\u56de\u3082\u304a\u697d\u3057\u307f\u306b\uff01<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u53c2\u8003\u6587\u732e\">\u53c2\u8003\u6587\u732e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u69d8\u3005\u306a\u8ad6\u6587\u3067TaqMan\u00ae Card\u306b\u3088\u308b\u5b9f\u9a13\u7d50\u679c\u304c\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u3054\u53c2\u8003\u307e\u3067\u306b\u4f8b\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Gallagher WM, et al. 2005. <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15958521\" target=\"_blank\" rel=\"noopener noreferrer\">Multiple markers for melanoma progression regulated by DNA methylation: insights from transcriptomic studies. Carcinogenesis.<\/a> Nov;26(11):1856-67.<\/li>\n\n\n\n<li>Abruzzo LV, et al. 2005. <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15945375\" target=\"_blank\" rel=\"noopener noreferrer\">Validation of oligonucleotide microarray data using microfluidic low-density arrays: a new statistical method to normalize real-time RT-PCR data.<\/a> Biotechniques. May;38(5):785-92.<\/li>\n\n\n\n<li>Tenedini E, et al. 2004. <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15271793\" target=\"_blank\" rel=\"noopener noreferrer\">Gene expression profiling of normal and malignant CD34-derived megakaryocytic cells.<\/a> Blood. Nov 15;104(10):3126-35.<\/li>\n\n\n\n<li>Marionneau C, et al. 2005. <a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/15498808\" target=\"_blank\" rel=\"noopener noreferrer\">Specific pattern of ionic channel gene expression associated with pacemaker activity in the mouse heart.<\/a> J Physiol. Jan 1;562(Pt 1):223-34.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0pcr\u30cf\u30f3\u30c9\u30d6\u30c3\u30af-\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\" style=\"font-size:25px\">\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30cf\u30f3\u30c9\u30d6\u30c3\u30af \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u7406\u8ad6\u3084\u5b9f\u9a13\u30c7\u30b6\u30a4\u30f3\u306e\u8a2d\u8a08\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u57fa\u790e\u77e5\u8b58\u304c\u63b2\u8f09\u3055\u308c\u305f\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u3092\u59cb\u3081\u305f\u3070\u304b\u308a\u306e\u65b9\u3084\u3053\u308c\u304b\u3089\u5b9f\u9a13\u3092\u8003\u3048\u3066\u3044\u308b\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/real-time-pcr-handbook-form.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr22_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0pcr\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0-\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\" style=\"font-size:25px\">\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0 \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u7570\u5e38\u306aS\u5b57\u72b6\u306e\u5897\u5e45\u66f2\u7dda\u3001NTC\u3067\u306e\u5897\u5e45\u691c\u51fa\u3001\u5897\u5e45\u304c\u898b\u3089\u308c\u306a\u3044\u306a\u3069\u3001\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u306e\u5b9f\u9a13\u4e2d\u306b\u56f0\u3063\u305f\u969b\u306e\u624b\u52a9\u3051\u306b\u306a\u308b\u60c5\u5831\u3092\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/pcr-system-troubleshooting.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr22_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<h4 class=\"wp-block-heading\" id=\"h-taqman-gene-expression\u30a2\u30c3\u30bb\u30a4\u5c0e\u5165\u30ac\u30a4\u30c9-\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\" style=\"font-size:25px\">TaqMan Gene Expression\u30a2\u30c3\u30bb\u30a4\u5c0e\u5165\u30ac\u30a4\u30c9 \u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">TaqMan\u30a2\u30c3\u30bb\u30a4\u3092\u3053\u308c\u304b\u3089\u4f7f\u3046\u65b9\u3001\u4f7f\u3063\u3066\u3044\u308b\u3051\u3069\u3082\u3063\u3068\u3088\u304f\u77e5\u308a\u305f\u3044\u65b9\u306b\u3046\u3063\u3066\u3064\u3051\u306e\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u3067\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u3057\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/taqman-guide-download.html?CID=gsd_pcr_sbu_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_op_awa_oc_s00_qpcr22_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<\/div>\n\n\n\n<div style=\"height:60px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u6700\u5927\u3067380\u3082\u306e\u907a\u4f1d\u5b50\u30921\u679a\u306e\u30d7\u30ec\u30fc\u30c8\u4e0a\u3067\u7db2\u7f85\u7684\u306b\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306a\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u300cTaqMan\u00ae Array Card\u300d\u3002\u7db2\u7f85\u6027\u3068\u5b9a\u91cf\u6027\u3001\u76f8\u53cd\u3059\u308b\u4e8c\u3064\u306e\u30cb\u30fc\u30ba\u3092\u6e80\u305f\u3059\u3053\u3068\u3092\u53ef\u80fd\u306b\u3057\u305f\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":975,"featured_media":2364,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[7],"division":[],"class_list":["post-236","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-qpcr","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u30e6\u30cb\u30d0\u30fc\u30b5\u30eb\u306aPCR\u6761\u4ef6\u306e\u5229\u70b9\u3092\u30d5\u30eb\u306b\u751f\u304b\u3057\u305f384\u30a6\u30a7\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306e\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u300cTaqMan\u00ae Array Card\u300d\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7\u3010\u7b2c21\u56de\u3011\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de\" \/>\n<meta property=\"og:description\" content=\"\u30e6\u30cb\u30d0\u30fc\u30b5\u30eb\u306aPCR\u6761\u4ef6\u306e\u5229\u70b9\u3092\u30d5\u30eb\u306b\u751f\u304b\u3057\u305f384\u30a6\u30a7\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306e\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u300cTaqMan\u00ae Array Card\u300d\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7\u3010\u7b2c21\u56de\u3011\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-01-13T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-10-16T09:23:42+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de\",\"datePublished\":\"2016-01-13T00:00:00+00:00\",\"dateModified\":\"2025-10-16T09:23:42+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/\"},\"wordCount\":135,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-20.jpg\",\"keywords\":[\"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/\",\"name\":\"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-20.jpg\",\"datePublished\":\"2016-01-13T00:00:00+00:00\",\"dateModified\":\"2025-10-16T09:23:42+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"description\":\"\u30e6\u30cb\u30d0\u30fc\u30b5\u30eb\u306aPCR\u6761\u4ef6\u306e\u5229\u70b9\u3092\u30d5\u30eb\u306b\u751f\u304b\u3057\u305f384\u30a6\u30a7\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306e\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u300cTaqMan\u00ae Array Card\u300d\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7\u3010\u7b2c21\u56de\u3011\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-20.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/qpcr-basic-title-20.jpg\",\"width\":1200,\"height\":630,\"caption\":\"qpcr-basic-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/qpcr-basic21\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de - Learning at the Bench","description":"\u30e6\u30cb\u30d0\u30fc\u30b5\u30eb\u306aPCR\u6761\u4ef6\u306e\u5229\u70b9\u3092\u30d5\u30eb\u306b\u751f\u304b\u3057\u305f384\u30a6\u30a7\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306e\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u300cTaqMan\u00ae Array Card\u300d\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7\u3010\u7b2c21\u56de\u3011","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/","og_locale":"ja_JP","og_type":"article","og_title":"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de","og_description":"\u30e6\u30cb\u30d0\u30fc\u30b5\u30eb\u306aPCR\u6761\u4ef6\u306e\u5229\u70b9\u3092\u30d5\u30eb\u306b\u751f\u304b\u3057\u305f384\u30a6\u30a7\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306e\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u300cTaqMan\u00ae Array Card\u300d\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7\u3010\u7b2c21\u56de\u3011","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-01-13T00:00:00+00:00","article_modified_time":"2025-10-16T09:23:42+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de","datePublished":"2016-01-13T00:00:00+00:00","dateModified":"2025-10-16T09:23:42+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/"},"wordCount":135,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20.jpg","keywords":["\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/","name":"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20.jpg","datePublished":"2016-01-13T00:00:00+00:00","dateModified":"2025-10-16T09:23:42+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"description":"\u30e6\u30cb\u30d0\u30fc\u30b5\u30eb\u306aPCR\u6761\u4ef6\u306e\u5229\u70b9\u3092\u30d5\u30eb\u306b\u751f\u304b\u3057\u305f384\u30a6\u30a7\u30eb\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306e\u30ab\u30b9\u30bf\u30e0\u30a2\u30ec\u30a4\u300cTaqMan\u00ae Array Card\u300d\u3092\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7\u3010\u7b2c21\u56de\u3011","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20.jpg","width":1200,"height":630,"caption":"qpcr-basic-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/qpcr-basic21\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u7db2\u7f85\u7684\u89e3\u6790\u306b\u306f\u3053\u308c! TaqMan\u00ae Array Card\uff5c\u4eca\u3053\u305d\u672c\u6c17\u3067\u5fb9\u5e95\u7406\u89e3! \u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR\u8b1b\u5ea7 \u7b2c21\u56de"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":7,"label":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20-1024x538.jpg",760,399,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":7,"name":"\u30ea\u30a2\u30eb\u30bf\u30a4\u30e0PCR","slug":"qpcr","term_group":0,"term_taxonomy_id":7,"taxonomy":"post_tag","description":"","parent":0,"count":91,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":236,"position":0},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":236,"position":1},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24545,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/digital-pcr-gene-expression-gsd-ts-sd-25082\/","url_meta":{"origin":236,"position":2},"title":"\u3010Absolute Q\u30c7\u30b8\u30bf\u30ebPCR\u30b7\u30b9\u30c6\u30e0\u306e\u6d3b\u7528\u4f8b\u3011\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2DNA\u306e\u5b9a\u91cf","author":"LatB Staff","date":"2026\u5e741\u670816\u65e5","format":false,"excerpt":"Applied Biosystems\u2122 QuantStudio\u2122 Absolute Q\u2122 \u30c7\u30b8\u30bf\u30ebP\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/digital-pcr-gene-expression-gsd-ts-sd-25082_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":236,"position":3},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24187,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/ngs-gene-expression-csd-ts-ion-25073\/","url_meta":{"origin":236,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u5fae\u91cf\u30fb\u5206\u89e3RNA\u306b\u3088\u308b\u767a\u73fe\u89e3\u6790\u306e\u6700\u9069\u89e3\u306f\uff1fRNA-Seq\u3068Ion AmpliSeq Transcriptome\u3092\u6bd4\u3079\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u670828\u65e5","format":false,"excerpt":"\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306e\u767a\u73fe\u89e3\u6790\u306b\u53d6\u308a\u7d44\u3080\u969b\u3001RNA\u30b5\u30f3\u30d7\u30eb\u304c\u300c\u5c11\u306a\u3059\u304e\u308b\u300d\u300c\u5206\u89e3\u3057\u3066\u3044\u308b\u300d\u3068\u3044\u3046\u72b6\u6cc1\u306f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/ngs-gene-expression-csd-ts-ion-25073_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":236,"position":5},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/qpcr-basic-title-20.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/236","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=236"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/236\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2364"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=236"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=236"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=236"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}