{"id":23765,"date":"2025-11-04T10:15:28","date_gmt":"2025-11-04T01:15:28","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=23765"},"modified":"2025-11-04T10:15:34","modified_gmt":"2025-11-04T01:15:34","slug":"cell-culture-cell-count-bid-ts-mbr-25065","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","title":{"rendered":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f"},"content":{"rendered":"\n<p>\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u6e2c\u5b9a\u304c\u4e0d\u6b63\u78ba\u3060\u3068\u3001\u5b9f\u9a13\u304c\u5931\u6557\u3057\u305f\u308a\u518d\u73fe\u6027\u304c\u640d\u306a\u308f\u308c\u305f\u308a\u3059\u308b\u6050\u308c\u304c\u3042\u308a\u307e\u3059\u3002\u63a5\u7740\u6027\u306e\u57f9\u990a\u7d30\u80de\u3092\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3059\u308b\u5834\u5408\u3001Trypsin-EDTA\u306a\u3069\u306e\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3067\u57f9\u990a\u5bb9\u5668\u304b\u3089\u7d30\u80de\u3092\u5265\u304c\u3057\u3001\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u8abf\u88fd\u3057\u307e\u3059\u3002\u9069\u5207\u306a\u6761\u4ef6\u3067\u5265\u304c\u305b\u3066\u3044\u308c\u3070\u3001\u591a\u304f\u306e\u57f9\u990a\u7d30\u80de\u306f\u4e00\u3064\u4e00\u3064\u306e\u7d30\u80de\u304c\u30d0\u30e9\u30d0\u30e9\u306a\u72b6\u614b\u306b\u306a\u308a\u307e\u3059\u3002\u4e00\u65b9\u3001\u30d2\u30c8\u809d\u81d3\u764c\u7531\u6765\u306e\u7d30\u80de\u682a\u3067\u3042\u308bHep G2\u306a\u3069\u3001\u7d30\u80de\u540c\u58eb\u304c\u63a5\u7740\u3057\u305f\u307e\u307e\u306e\u72b6\u614b\u306b\u306a\u308a\u3084\u3059\u3044\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u308b\u7d30\u80de\u3082\u3042\u308a\u307e\u3059\u3002\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u969b\u306b\u51dd\u96c6\u3057\u3066\u3044\u308b\u7d30\u80de\u304c\u76ee\u7acb\u3064\u5834\u5408\u3001\u7686\u3055\u3093\u306f\u3069\u306e\u3088\u3046\u306b\u30ab\u30a6\u30f3\u30c8\u3057\u3066\u3044\u307e\u3059\u304b\uff1f<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u898b\u5206\u3051\u3089\u308c\u308b\u7bc4\u56f2\u3067\u3067\u304d\u308b\u3060\u3051\u30ab\u30a6\u30f3\u30c8\u3059\u308b<\/li>\n\n\n\n<li>\u51dd\u96c6\u4e00\u3064\u3092\u7d30\u80de\u4e00\u3064\u3068\u3057\u3066\u30ab\u30a6\u30f3\u30c8\u3059\u308b<\/li>\n\n\n\n<li>\u51dd\u96c6\u306f\u30ab\u30a6\u30f3\u30c8\u3057\u306a\u3044\uff08\u7121\u8996\u3059\u308b\uff09<\/li>\n<\/ul>\n\n\n\n<p>\u3044\u308d\u3044\u308d\u306a\u3084\u308a\u65b9\u304c\u8003\u3048\u3089\u308c\u307e\u3059\u304c\u3001\u3069\u306e\u65b9\u6cd5\u3067\u3082\u5b9f\u969b\u306e\u7d30\u80de\u6570\u3088\u308a\u3082\u5c11\u306a\u304f\u898b\u7a4d\u3082\u3063\u3066\u3057\u307e\u3046\u30ea\u30b9\u30af\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u57f9\u990a\u5bb9\u5668\u304b\u3089\u5265\u304c\u3057\u305fHep G2\u3092\u30d0\u30e9\u30d0\u30e9\u306b\u307b\u3050\u305b\u306a\u3044\u304b\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3092\u4f7f\u3063\u3066\u691c\u8a0e\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u7d50\u679c\u3068\u3057\u3066\u5b8c\u5168\u306b\u30d0\u30e9\u30d0\u30e9\u306b\u306f\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001\u7686\u3055\u3093\u306e\u4eca\u5f8c\u306e\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u30d2\u30f3\u30c8\u306b\u306a\u308c\u3070\u5e78\u3044\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"771\" height=\"580\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/5e1bf06b59c41a7df1f53946ef67736a.png\" alt=\"\" class=\"wp-image-23769\" style=\"width:550px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/5e1bf06b59c41a7df1f53946ef67736a.png 771w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/5e1bf06b59c41a7df1f53946ef67736a-300x226.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/5e1bf06b59c41a7df1f53946ef67736a-768x578.png 768w\" sizes=\"auto, (max-width: 771px) 100vw, 771px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\"><strong>\u56f31. Hep G2\u306f\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3068\u3057\u3066\u77e5\u3089\u308c\u3066\u3044\u308b<\/strong><br>\uff08\u5199\u771f\u306f\u30c7\u30a3\u30c3\u30b7\u30e5\u306b\u5f35\u308a\u4ed8\u3044\u3066\u3044\u308bHep G2\uff09<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3067\u304a\u56f0\u308a\u306e\u65b9<\/li>\n\n\n\n<li>\u63a5\u7740\u7d30\u80de\u306e\u5265\u304c\u3057\u65b9\u3067\u304a\u56f0\u308a\u306e\u65b9<\/li>\n\n\n\n<li>\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u8208\u5473\u306e\u3042\u308b\u65b9<\/li>\n<\/ul>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5b9f\u9a13\u65b9\u6cd5\">\u5b9f\u9a13\u65b9\u6cd5<\/h2>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u57fa\u672c\u624b\u9806\">\u25a0\u57fa\u672c\u624b\u9806<\/h4>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Hep G2\u309260 mm\u306eThermo Scientific\u2122 Nunc\u2122 EasYDish\u2122 Cell Culture Dish\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/150462?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">150462<\/a>\uff09\u3067\u57f9\u990a<\/li>\n\n\n\n<li>Gibco\u2122 DPBS, no calcium, no magnesium\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/14190144?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">14190144<\/a>\uff09\u30924 mL\u6dfb\u52a0\u3057\u3066\u6d17\u6d44<\/li>\n\n\n\n<li>Gibco\u2122 TrypLE\u2122 Select Enzyme (1X)\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/12563011?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">12563011<\/a>\uff09\u30922 mL\u6dfb\u52a0<\/li>\n\n\n\n<li>CO2\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30bf\u30fc\u3067\u51e6\u7406\uff0837 \u2103\u300110\u5206\u9593\uff09<\/li>\n\n\n\n<li>2 mL\u306e\u8840\u6e05\u5165\u308aGibco\u2122 DMEM\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/11995065?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">11995065<\/a>\uff09\u3092\u6dfb\u52a0\u3057\u3066\u53cd\u5fdc\u505c\u6b62<\/li>\n\n\n\n<li>15 mL\u306e\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/339650?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">339650<\/a>\uff09\u306b\u56de\u53ce\u3057\u3001200 \u00d7g\u30673\u5206\u9593\u9060\u5fc3<\/li>\n\n\n\n<li>\u4e0a\u6f84\u307f\u3092\u9664\u53bb\u3057\u30011 mL\u306e\u8840\u6e05\u5165\u308aDMEM\u3067\u518d\u61f8\u6fc1<\/li>\n\n\n\n<li>\u7d30\u80de\u61f8\u6fc1\u6db2\u3068Gibco\u2122 Trypan Blue Solution\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/15250061?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">15250061<\/a>\uff09\u30921:1\u3067\u6df7\u5408<\/li>\n\n\n\n<li>\u6df7\u5408\u6db2\u3092Invitrogen\u2122 Countess\u2122 Cell Counting Chamber Slide\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/C10283?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">C10283<\/a>\uff09\u306b\u6ce8\u5165<\/li>\n\n\n\n<li>Invitrogen\u2122 Countess\u2122 3 FL \u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/AMQAF2000?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">AMQAF2000<\/a>\uff09\u306e\u660e\u8996\u91ce\u30e2\u30fc\u30c9\u3067\u7d30\u80de\u6fc3\u5ea6\u3001\u751f\u7d30\u80de\u7387\u3001\u6b7b\u7d30\u80de\u7387\u3001\u51dd\u96c6\u7387\u3092\u6e2c\u5b9a<\/li>\n<\/ol>\n\n\n\n<p>\u4eca\u56de\u306f\u3001\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3068\u3057\u3066TrypLE Select Enzyme\u3092\u4f7f\u3044\u307e\u3057\u305f\u3002Trypsin\u3068\u540c\u69d8\u306e\u9175\u7d20\u6d3b\u6027\u3092\u6301\u3064\u7d44\u307f\u63db\u3048\u9175\u7d20TrypLE Enzyme\u3068EDTA\u304c\u542b\u307e\u308c\u308b\u8a66\u85ac\u3067\u3001Trypsin-EDTA\u306e\u4ee3\u308f\u308a\u306b\u4f7f\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u8a73\u3057\u304f\u306f\u95a2\u9023\u8a18\u4e8b\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-separation-bid-ts-mbr-24001\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30b7\u30f3\u30b0\u30eb\u30bb\u30eb\u89e3\u6790\u3084\u521d\u4ee3\u57f9\u990a\u306b\u4f7f\u308f\u308c\u308b\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u306e\u9078\u629e\u30ac\u30a4\u30c9<\/a>\u300d\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p>\u307e\u305f\u3001\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3067\u306fCountess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306e\u660e\u8996\u91ce\u30e2\u30fc\u30c9\u3092\u4f7f\u3063\u3066\u3001\u7d30\u80de\u6fc3\u5ea6\u3001\u751f\u7d30\u80de\u7387\u3001\u6b7b\u7d30\u80de\u7387\u3001\u51dd\u96c6\u7387\u3092\u6e2c\u5b9a\u3057\u307e\u3057\u305f\u3002\u6a19\u6e96\u7684\u306a\u30d7\u30ed\u30c8\u30b3\u30eb\u3067Hep G2\u3092\u5265\u304c\u3059\u3068\u591a\u304f\u306e\u51dd\u96c6\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u3067\u306f\u3001\u56f32\u306e\u3088\u3046\u306b\u51dd\u96c6\u3057\u3066\u3044\u308b\u7d30\u80de\u96c6\u56e3\u3092\u8b58\u5225\u3057\u3066\u9ec4\u8272\u306e\u5186\u3067\u30de\u30fc\u30af\u3057\u3066\u305d\u306e\u6bd4\u7387\u3092\u8868\u793a\u3057\u307e\u3059\u3002\u3053\u306e\u4f8b\u3067\u306f\u3001\u5168\u4f53\u306e47%\u306e\u7d30\u80de\u304c\u51dd\u96c6\u3057\u305f\u96c6\u56e3\u306b\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u306a\u304a\u3001\u51dd\u96c6\u7387\u306f\u51dd\u96c6\u306b\u542b\u307e\u308c\u3066\u3044\u308b\u7d30\u80de\u6570\u3092\u5168\u7d30\u80de\u6570\u3067\u5272\u3063\u305f\u6bd4\u7387\u3067\u3059\u3002\u4eca\u56de\u306e\u691c\u8a0e\u3067\u306f\u3001\u3053\u306e\u51dd\u96c6\u7387\u3092\u4e0b\u3052\u3066\u3044\u304f\u3053\u3068\u304c\u76ee\u6a19\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"918\" height=\"577\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/4a58d66221d3eae6452ae34636194bbd.png\" alt=\"\u56f32. Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306f\u7d30\u80de\u6fc3\u5ea6\u3001\u751f\uff0f\u6b7b\u7d30\u80de\u7387\u3001\u51dd\u96c6\u7387\u3092\u6e2c\u5b9a\u3067\u304d\u308b\" class=\"wp-image-23796\" style=\"width:640px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/4a58d66221d3eae6452ae34636194bbd.png 918w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/4a58d66221d3eae6452ae34636194bbd-300x189.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/4a58d66221d3eae6452ae34636194bbd-768x483.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/4a58d66221d3eae6452ae34636194bbd-320x200.png 320w\" sizes=\"auto, (max-width: 918px) 100vw, 918px\" \/><\/figure>\n\n\n\n<p><strong>\u56f32. Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306f\u7d30\u80de\u6fc3\u5ea6\u3001\u751f\uff0f\u6b7b\u7d30\u80de\u7387\u3001\u51dd\u96c6\u7387\u3092\u6e2c\u5b9a\u3067\u304d\u308b<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u305f\u304f\u3055\u3093\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u307f\u305f\">\u305f\u304f\u3055\u3093\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u307f\u305f<\/h2>\n\n\n\n<p>\u7d30\u80de\u61f8\u6fc1\u6db2\u306b\u542b\u307e\u308c\u308b\u51dd\u96c6\u3092\u307b\u3050\u3059\u65b9\u6cd5\u3068\u3057\u3066\u3082\u3063\u3068\u3082\u30b7\u30f3\u30d7\u30eb\u306a\u306e\u306f\u3001\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u56de\u6570\u3092\u5897\u3084\u3059\u3053\u3068\u3067\u3059\u3002\u305d\u3053\u3067\u30011 mL\u306eHep G2\u7d30\u80de\u61f8\u6fc1\u6db2\u30921,000 \u00b5L\u306e\u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7\u30675\u56de\u300110\u56de\u300130\u56de\u300150\u56de\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3092\u56f33\u306b\u793a\u3057\u307e\u3059\u30025\u56de\u3088\u308a\u308210\u56de\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u51dd\u96c6\u7387\u304c\u4f4e\u4e0b\u3057\u307e\u3057\u305f\u304c\u3001\u305d\u308c\u4ee5\u4e0a\u3044\u304f\u3089\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u3082\u51dd\u96c6\u7387\u306f\u4f4e\u4e0b\u3057\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u306a\u304a\u3001\u3053\u306e\u6642\u306eHep G2\u306e\u751f\u7d30\u80de\u7387\u306f\u305d\u308c\u305e\u308c\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u56de\u6570\u306792.8%\u300190.3%\u300191.3%\u300190.5%\u3067\u3001\u7d71\u8a08\u7684\u306a\u6709\u610f\u5dee\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u56de\u6570\u304c\u751f\u7d30\u80de\u7387\u306b\u307b\u307c\u5f71\u97ff\u3057\u306a\u3044\u7d50\u679c\u306fHeLa\u3067\u884c\u3063\u305f\u4ee5\u524d\u306e\u691c\u8a3c\u7d50\u679c\uff08\u95a2\u9023\u8a18\u4e8b\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-cell-culture-bid-ts-mbr-25014\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u7d30\u80de\u3092100\u56de\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u307f\u305f<\/a>\u300d\uff09\u3067\u3082\u540c\u69d8\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"570\" height=\"547\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/3b0448cd13dd57886168dbe679cf3bc8.png\" alt=\"\u56f33. \u305f\u304f\u3055\u3093\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u3082Hep G2\u306f\u307b\u3050\u308c\u306a\u3044\" class=\"wp-image-23803\" style=\"width:420px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/3b0448cd13dd57886168dbe679cf3bc8.png 570w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/3b0448cd13dd57886168dbe679cf3bc8-300x288.png 300w\" sizes=\"auto, (max-width: 570px) 100vw, 570px\" \/><\/figure>\n\n\n\n<p><strong>\u56f33. \u305f\u304f\u3055\u3093\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3057\u3066\u3082Hep G2\u306f\u307b\u3050\u308c\u306a\u3044<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u3092\u901a\u3057\u3066\u307f\u305f\">\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u3092\u901a\u3057\u3066\u307f\u305f<\/h2>\n\n\n\n<p>\u7d30\u80de\u61f8\u6fc1\u6db2\u304b\u3089\u51dd\u96c6\u7269\u3084\u5927\u304d\u306a\u7570\u7269\u3092\u53d6\u308a\u9664\u304f\u6d88\u8017\u54c1\u3068\u3057\u3066\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u3068\u3044\u3046\u88fd\u54c1\u304c\u3042\u308a\u307e\u3059\u3002\u657010 \u00b5m\u7a0b\u5ea6\u306e\u7a74\u304c\u958b\u3044\u3066\u3044\u308b\u30e1\u30c3\u30b7\u30e5\u3092\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6\u306b\u30bb\u30c3\u30c8\u3057\u3001\u30e1\u30c3\u30b7\u30e5\u3092\u901a\u3057\u305f\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u30c1\u30e5\u30fc\u30d6\u306b\u56de\u53ce\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305d\u3053\u3067\u4eca\u56de\u306f\u30dd\u30a2\u30b5\u30a4\u30ba40 \u00b5m\u306e\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u306e\u52b9\u679c\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u51dd\u96c6\u7387\u30922\/3\u306b\u4f4e\u4e0b\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u304c\u3001\u51dd\u96c6\u3092\u5b8c\u5168\u306b\u9664\u304f\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\uff08\u56f34\uff09\u3002\u306a\u304a\u3001\u4eca\u56de\u306fFisherbrand\u2122\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/wexer-store.com\/fisher_product\/cell_strainer\/88\" target=\"_blank\" rel=\"noreferrer noopener\">22-363-547<\/a>\uff09\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u30e9\u30a4\u30f3\u30a2\u30c3\u30d7\u306e\u4e2d\u3067\u306f\u30dd\u30a2\u30b5\u30a4\u30ba\u304c\u4e00\u756a\u5c0f\u3055\u3044\u88fd\u54c1\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"378\" height=\"376\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/7af5f9952540f6c6e1204aa64e610f36.png\" alt=\"\u56f34. \u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u3092\u901a\u3059\u3053\u3053\u3068\u3067\u51dd\u96c6\u3057\u305f\u7d30\u80de\u306e\u4e00\u90e8\u3092\u9664\u3051\u308b\" class=\"wp-image-23808\" style=\"width:420px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/7af5f9952540f6c6e1204aa64e610f36.png 378w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/7af5f9952540f6c6e1204aa64e610f36-300x298.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/7af5f9952540f6c6e1204aa64e610f36-150x150.png 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/7af5f9952540f6c6e1204aa64e610f36-80x80.png 80w\" sizes=\"auto, (max-width: 378px) 100vw, 378px\" \/><\/figure>\n\n\n\n<p><strong>\u56f34. \u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u3092\u901a\u3059\u3053\u3053\u3068\u3067\u51dd\u96c6\u3057\u305f\u7d30\u80de\u306e\u4e00\u90e8\u3092\u9664\u3051\u308b<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Countess 3 FL \u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306f\u3001\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3068\u540c\u6642\u306b\u7d30\u80de\u306e\u30b5\u30a4\u30ba\u3082\u8a08\u6e2c\u3057\u3066\u3044\u307e\u3059\u3002\u30c7\u30fc\u30bf\u3092PDF\u5f62\u5f0f\u306e\u30ec\u30dd\u30fc\u30c8\u3067\u51fa\u529b\u3059\u308b\u3068\u3001\u5e73\u5747\u30b5\u30a4\u30ba\u3084\u30b5\u30a4\u30ba\u5206\u5e03\u306e\u30d2\u30b9\u30c8\u30b0\u30e9\u30e0\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08\u56f35\uff09\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"537\" height=\"402\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/9b05939e00c3567acf6d1c7e56f22be5.png\" alt=\"\u56f35. Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306f\u7d30\u80de\u30b5\u30a4\u30ba\u306e\u5206\u5e03\u3092\u30d2\u30b9\u30c8\u30b0\u30e9\u30e0\u8868\u793a\u3067\u304d\u308b\" class=\"wp-image-23813\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/9b05939e00c3567acf6d1c7e56f22be5.png 537w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/9b05939e00c3567acf6d1c7e56f22be5-300x225.png 300w\" sizes=\"auto, (max-width: 537px) 100vw, 537px\" \/><\/figure>\n\n\n\n<p><strong>\u56f35. Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306f\u7d30\u80de\u30b5\u30a4\u30ba\u306e\u5206\u5e03\u3092\u30d2\u30b9\u30c8\u30b0\u30e9\u30e0\u8868\u793a\u3067\u304d\u308b<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u304b\u3089\u51fa\u529b\u3055\u308c\u308b\u30d2\u30b9\u30c8\u30b0\u30e9\u30e0\u306e\u5de6\u4e0b\u3068\u53f3\u4e0b\u306b\u3001\u751f\u7d30\u80de\u3068\u6b7b\u7d30\u80de\u306e\u305d\u308c\u305e\u308c\u306e\u5e73\u5747\u30b5\u30a4\u30ba\u304c\u8868\u793a\u3055\u308c\u307e\u3059\u3002\u30d2\u30b9\u30c8\u30b0\u30e9\u30e0\u304b\u3089\u3001\u6d6e\u904a\u72b6\u614b\u306eHep G2\u306e\u307b\u3068\u3093\u3069\u306f10\uff5e20 \u00b5m\u7a0b\u306e\u30b5\u30a4\u30ba\u3067\u3042\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002\u4eca\u56de\u4f7f\u7528\u3057\u305f\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u306e\u30dd\u30a2\u30b5\u30a4\u30ba\u306f40 \u00b5m\u306a\u306e\u3067\u30012\uff5e\u6570\u500b\u306e\u7d30\u80de\u3067\u3067\u304d\u305f\u51dd\u96c6\u306f\u30e1\u30c3\u30b7\u30e5\u3092\u901a\u904e\u3057\u3066\u3082\u304a\u304b\u3057\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u305d\u306e\u7d50\u679c\u3057\u3066\u3001\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u3067\u306f\u51dd\u96c6\u3092\u9664\u304d\u304d\u308c\u306a\u304b\u3063\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3067\u9577\u304f\u51e6\u7406\u3057\u3066\u307f\u305f\">\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3067\u9577\u304f\u51e6\u7406\u3057\u3066\u307f\u305f<\/h2>\n\n\n\n<p>\u3053\u3053\u307e\u3067\u306e\u7d50\u679c\u304b\u3089\u3001\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u7269\u7406\u7684\u306b\u5f8c\u51e6\u7406\u3057\u3066\u51dd\u96c6\u7387\u3092\u4e0b\u3052\u308b\u306e\u306f\u96e3\u3057\u3044\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u305d\u3053\u3067\u3001\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3067\u306e\u51e6\u7406\u6642\u9593\u3092\u5ef6\u9577\u3057\u3066\u5206\u6563\u4f5c\u7528\u3092\u5f37\u3081\u3066\u307f\u308b\u3053\u3068\u306b\u3057\u307e\u3057\u305f\u3002\u5177\u4f53\u7684\u306b\u306f\u3001TrypLE Select Enzyme\u3067\u306e\u51e6\u7406\u6642\u9593\u309210\u5206\u304b\u308920\u5206\u300130\u5206\u306b\u5ef6\u9577\u3057\u3066\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u306a\u304a\u3001\u4ee5\u964d\u306e\u5b9f\u9a13\u3067\u306f\u3001\u56de\u53ce\u3057\u305f\u7d30\u80de\u61f8\u6fc1\u6db2\u306f\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u3092\u901a\u3057\u3066\u304b\u3089\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"446\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/c5144732a8f5b8587e91209485d2ef47-1024x446.png\" alt=\"\u56f36. TrypLE Select Enzyme\u306b\u3088\u308b\u51e6\u7406\u6642\u9593\u3092\u5ef6\u3070\u3059\u3068\u51dd\u96c6\u7387\u304c\u4f4e\u4e0b\u3059\u308b\" class=\"wp-image-23819\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/c5144732a8f5b8587e91209485d2ef47-1024x446.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/c5144732a8f5b8587e91209485d2ef47-300x131.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/c5144732a8f5b8587e91209485d2ef47-768x334.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/c5144732a8f5b8587e91209485d2ef47.png 1188w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p><strong>\u56f36. TrypLE Select Enzyme\u306b\u3088\u308b\u51e6\u7406\u6642\u9593\u3092\u5ef6\u3070\u3059\u3068\u51dd\u96c6\u7387\u304c\u4f4e\u4e0b\u3059\u308b<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u305d\u306e\u7d50\u679c\u3001TrypLE Select Enzyme\u306b\u3088\u308b\u51e6\u7406\u309230\u5206\u9593\u307e\u3067\u5ef6\u9577\u3059\u308b\u3053\u3068\u3067\u3001\u51dd\u96c6\u7387\u3092\u5f53\u521d\u306e\u534a\u5206\u4ee5\u4e0b\u306b\u307e\u3067\u4e0b\u3052\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\uff08\u56f36\u5de6\uff09\u3002\u307e\u305f\u3001\u3053\u306e\u3068\u304d\u306b\u5fc3\u914d\u3055\u308c\u308b\u751f\u7d30\u80de\u7387\u306f\u5f71\u97ff\u3092\u53d7\u3051\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\uff08\u56f36\u53f3\uff09\u3002\u3053\u308c\u3089\u7d50\u679c\u304b\u3089\u3001\u7d30\u80de\u306e\u51dd\u96c6\u7387\u3092\u4e0b\u3052\u308b\u306b\u306f\u89e3\u96e2\u9175\u7d20\u51e6\u7406\u306e\u6761\u4ef6\u3092\u5f37\u3081\u308b\u3053\u3068\u304c\u6709\u52b9\u3067\u3042\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u300130\u5206\u51e6\u7406\u3057\u3066\u3082\u5b8c\u5168\u306b\u306f\u5206\u6563\u3055\u305b\u3089\u308c\u305a\u3001\u65e5\u5e38\u7684\u306b\u306f10\u5206\u4ee5\u4e0b\u306e\u51e6\u7406\u3067\u7d99\u4ee3\u3055\u308c\u3066\u3044\u308b\u3067\u3042\u308d\u3046Hep G2\u306e\u89e3\u96e2\u64cd\u4f5c\u306b\u3053\u308c\u4ee5\u4e0a\u306e\u6642\u9593\u3092\u304b\u3051\u308b\u306e\u306f\u73fe\u5b9f\u7684\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3057\u3001\u7d30\u80de\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3082\u61f8\u5ff5\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u3082\u3063\u3068\u5f37\u3044\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3067\u9577\u304f\u51e6\u7406\u3057\u3066\u307f\u305f\">\u3082\u3063\u3068\u5f37\u3044\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u3067\u9577\u304f\u51e6\u7406\u3057\u3066\u307f\u305f<\/h2>\n\n\n\n<p>\u305d\u3053\u3067\u4eca\u5ea6\u306fTrypLE Select Enzyme\u306e10\u500d\u6fc3\u7e2e\u7248\uff08\u88fd\u54c1\u756a\u53f7 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/A1217701?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">A1217701<\/a>\uff09\u3092\u4f7f\u3046\u3053\u3068\u306b\u3057\u307e\u3057\u305f\u3002\u3053\u3061\u3089\u3092\u4f7f\u3048\u3070\u3001\u51e6\u7406\u6642\u9593\u3092\u5ef6\u9577\u305b\u305a\u306b\u9175\u7d20\u51e6\u7406\u3092\u5f37\u3081\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002TrypLE Select Enzyme\u306e\u901a\u5e38\u7248(1X)\u306730\u5206\u9593\u300110\u500d\u6fc3\u7e2e\u7248\uff0810X)\u306710\u5206\u9593\u306830\u5206\u9593\u3067\u51e6\u7406\u3057\u3066\u7d30\u80de\u61f8\u6fc1\u6db2\u3092\u56de\u53ce\u3057\u3001\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"713\" height=\"507\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/452bc0b3dfe460b825c4af72aa8dc13a.png\" alt=\"\u56f37. TrypLE Select Enzyme\u51e6\u7406\u3092\u5f37\u3081\u3066\u3082\u51dd\u96c6\u7387\u306e\u4f4e\u6e1b\u52b9\u679c\u306f\u5c0f\u3055\u3044\" class=\"wp-image-23825\" style=\"width:480px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/452bc0b3dfe460b825c4af72aa8dc13a.png 713w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/452bc0b3dfe460b825c4af72aa8dc13a-300x213.png 300w\" sizes=\"auto, (max-width: 713px) 100vw, 713px\" \/><\/figure>\n\n\n\n<p><strong>\u56f37. TrypLE Select Enzyme\u51e6\u7406\u3092\u5f37\u3081\u3066\u3082\u51dd\u96c6\u7387\u306e\u4f4e\u6e1b\u52b9\u679c\u306f\u5c0f\u3055\u3044<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u305d\u306e\u7d50\u679c\u300110\u500d\u6fc3\u7e2e\u7248\u306eTrypLE Select Enzyme\u3092\u4f7f\u7528\u3057\u3066\u3082\u3001\u51dd\u96c6\u7387\u3092\u9855\u8457\u306b\u4e0b\u3052\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002Hep G2\u306e\u51dd\u96c6\u306e\u3057\u3084\u3059\u3055\u306b\u306f\u3001TrypLE Enzyme\u306e\u9175\u7d20\u6d3b\u6027\u3067\u306f\u89e3\u6c7a\u3067\u304d\u306a\u3044\u8981\u56e0\u304c\u3042\u308a\u305d\u3046\u3067\u3059\u3002\u306a\u304a\u3001\u3053\u306e\u6642\u306e\u751f\u7d30\u80de\u7387\u306f\u3069\u306e\u6761\u4ef6\u3067\u308290%\u4ee5\u4e0a\u3067\u6709\u610f\u5dee\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001\u305d\u306e\u7d30\u80de\u3092\u57f9\u990a\u3057\u3066\u307f\u308b\u306810\u500d\u6fc3\u7e2e\u7248\u306eTrypLE Select Enzyme\u3067\u51e6\u7406\u3057\u305f\u7d30\u80de\u306e\u5897\u6b96\u7387\u304c\u308f\u305a\u304b\u306b\u4f4e\u4e0b\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u89e3\u96e2\u76f4\u5f8c\u306e\u751f\u7d30\u80de\u7387\u306b\u554f\u984c\u304c\u306a\u304f\u3068\u3082\u3001\u305d\u306e\u5f8c\u306e\u5897\u6b96\u306b\u60aa\u5f71\u97ff\u304c\u8d77\u3053\u308a\u3046\u308b\u3053\u3068\u306f\u5ff5\u982d\u306b\u304a\u3044\u3066\u304f\u3060\u3055\u3044\u3002\u306a\u304a\u3001HeLa\u3067\u884c\u3063\u305f\u4ee5\u524d\u306e\u691c\u8a3c\u3067\u3082\u985e\u4f3c\u306e\u7d50\u679c\u304c\u5f97\u3089\u308c\u3066\u3044\u307e\u3057\u305f\uff08\u95a2\u9023\u8a18\u4e8b\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25012\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u201d\u3084\u3055\u3057\u3044\u201d\u7d30\u80de\u89e3\u96e2\u8a66\u85ac\u300cTrypLE\u300d\u3067\u7d30\u80de\u3092\u304d\u3073\u3057\u304f\u51e6\u7406\u3057\u3066\u307f\u305f<\/a>\u300d\uff09\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p>\u4eca\u56de\u306f\u3001\u51dd\u96c6\u3057\u3084\u3059\u3044\u6027\u8cea\u304c\u3042\u308bHep G2\u3092\u7528\u3044\u3066\u3001\u51dd\u96c6\u3092\u307b\u3050\u3059\u305f\u3081\u306b\u3042\u306e\u624b\u3053\u306e\u624b\u3092\u8a66\u3057\u3066\u307f\u307e\u3057\u305f\u3002\u5b8c\u5168\u306b\u307b\u3050\u3059\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u3059\u308c\u3070\u3059\u308b\u307b\u3069\u307b\u3050\u308c\u308b\u308f\u3051\u3067\u306f\u306a\u3044<\/li>\n\n\n\n<li>\u30bb\u30eb\u30b9\u30c8\u30ec\u30fc\u30ca\u30fc\u306f\u591a\u5c11\u306e\u52b9\u679c\u304c\u3042\u308b<\/li>\n\n\n\n<li>\u89e3\u96e2\u9175\u7d20\u51e6\u7406\u306e\u5ef6\u9577\u306f\u52b9\u679c\u304c\u3042\u308b\u304c\u3001\u5b8c\u5168\u3067\u306f\u306a\u3044<\/li>\n<\/ul>\n\n\n\n<p>\u306a\u3069\u306e\u7d50\u679c\u3092\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p>Hep G2\u306e\u3088\u3046\u306b\u5b8c\u5168\u306b\u5206\u6563\u3055\u305b\u308b\u3053\u3068\u304c\u96e3\u3057\u3044\u7d30\u80de\u3092\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3059\u308b\u5834\u5408\u306f\u3001\u7d30\u80de\u304c\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u306a\u3044\u7a0b\u5ea6\u306b\u3057\u3063\u304b\u308a\u3068\u89e3\u96e2\u9175\u7d20\u3092\u52b9\u304b\u305b\u3066\u3067\u304d\u308b\u3060\u3051\u5206\u6563\u3055\u305b\u3001\u51dd\u96c6\u306b\u542b\u307e\u308c\u308b\u7d30\u80de\u3082\u3067\u304d\u308b\u3060\u3051\u30ab\u30a6\u30f3\u30c8\u3057\u305f\u65b9\u304c\u5b9f\u969b\u306e\u6fc3\u5ea6\u306b\u8fd1\u3044\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u4eca\u56de\u306e\u691c\u8a3c\u3067\u4f7f\u7528\u3057\u305fCountess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306f\u3001\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u306e\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u3082\u3042\u308b\u7a0b\u5ea6\u5bfe\u5fdc\u3067\u304d\u307e\u3059\uff08\u56f38\uff09\u3002\u305f\u3060\u3057\u3001\u753b\u50cf\u89e3\u6790\u3067\u30ab\u30a6\u30f3\u30c8\u3057\u3066\u3044\u308b\u4ed5\u7d44\u307f\u3067\u3059\u306e\u3067\u3001\u4eba\u9593\u306e\u76ee\u3067\u898b\u3066\u3082\u898b\u5206\u3051\u3089\u308c\u306a\u3044\u3088\u3046\u306a\u5927\u304d\u306a\u51dd\u96c6\u306e\u30ab\u30a6\u30f3\u30c8\u306b\u306f\u5bfe\u5fdc\u3067\u304d\u307e\u305b\u3093\u3002\u81ea\u5206\u306e\u5224\u5b9a\u3068\u4e00\u81f4\u3057\u3066\u3044\u308b\u304b\u3069\u3046\u304b\u3092\u3001\u6e2c\u5b9a\u753b\u9762\u3092\u898b\u3066\u78ba\u8a8d\u3057\u306a\u304c\u3089\u4e0a\u624b\u306b\u6d3b\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u65e5\u5e38\u306e\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u304c\u8ca0\u62c5\u306b\u611f\u3058\u3066\u3044\u308b\u65b9\u3084\u6b63\u78ba\u6027\u306b\u4e0d\u5b89\u304c\u3042\u308b\u65b9\u306f\u3001\u305c\u3072\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\uff08<a href=\"mailto:jptech@thermofisher.com?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">jptech@thermofisher.com<\/a>\uff09\u3078\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"832\" height=\"511\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/fc8bdc8ab731852b565dc58b0cd876b7.png\" alt=\"\" class=\"wp-image-23830\" style=\"width:628px;height:auto\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/fc8bdc8ab731852b565dc58b0cd876b7.png 832w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/fc8bdc8ab731852b565dc58b0cd876b7-300x184.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/fc8bdc8ab731852b565dc58b0cd876b7-768x472.png 768w\" sizes=\"auto, (max-width: 832px) 100vw, 832px\" \/><\/figure>\n\n\n\n<p><strong>\u56f38. Countess 3 FL\u81ea\u52d5\u30bb\u30eb\u30ab\u30a6\u30f3\u30bf\u30fc\u306f\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u8ca0\u62c5\u3092\u8efd\u6e1b\u3059\u308b<\/strong><\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u3064\u3044\u3066\u3082\u3063\u3068\u77e5\u308a\u305f\u3044\u65b9\u306f\u7121\u6599\u306e\u30aa\u30f3\u30e9\u30a4\u30f3\u30bb\u30df\u30ca\u30fc\u300c<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/seminars\/cell-count-basic.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u3044\u307e\u3055\u3089\u805e\u3051\u306a\u3044\uff01\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\u3092\u57fa\u672c\u304b\u3089\u5b66\u307c\u3046<\/a>\u300d\u3084\u8b1b\u7fa9\u3068\u5b9f\u7fd2\u3067\u7d30\u80de\u57f9\u990a\u306e\u57fa\u672c\u3092\u7fd2\u5f97\u3067\u304d\u308b\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30ba\u30aa\u30f3\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\uff08<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/saibo_baiyo.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">1\u65e5\u30b3\u30fc\u30b9<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/technical-resources\/trainings\/saibo-baiyo2.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">2\u65e5\u9593\u30b3\u30fc\u30b9<\/a>\uff09\u306e\u53d7\u8b1b\u3092\u3054\u691c\u8a0e\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u3089\u306e\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3067\u5b66\u3079\u308b\u5185\u5bb9\u306e\u9055\u3044\u306b\u3064\u3044\u3066\u306f\u95a2\u9023\u8a18\u4e8b\u300c<a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-stem-cell-bid-ts-mbr-24038\/?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d30\u80de\u57f9\u990a\u95a2\u9023\u306e\u5b66\u7fd2\u30ea\u30bd\u30fc\u30b9\u307e\u3068\u3081\uff5e\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u30fb\u30bb\u30df\u30ca\u30fc\u30fb\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u306a\u3069\uff5e<\/a>\u300d\u3067\u6574\u7406\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306b\u9650\u3089\u305a\u3001\u7d30\u80de\u57f9\u990a\u95a2\u9023\u306e\u8a66\u85ac\u30fb\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306a\u3069\u3067\u3054\u4e0d\u660e\u70b9\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\uff08<a href=\"mailto:jptech@thermofisher.com?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">jptech@thermofisher.com<\/a>\uff09\u3078\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-gibco\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9-2021\u5e74\u30ea\u30cb\u30e5\u30fc\u30a2\u30eb\u7248\">Gibco\u7d30\u80de\u57f9\u990a\u30cf\u30f3\u30c9\u30d6\u30c3\u30af\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\uff082021\u5e74\u30ea\u30cb\u30e5\u30fc\u30a2\u30eb\u7248\uff09<\/h4>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/gibco-cell-culture-basics-handbook-form.html?CID=bid_clb_r04_jp_cp0000_pjt0000_bid00000_0so_blg_cell_culture_cell_count_bid_ts_mbr_25065_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u6e2c\u5b9a\u304c\u4e0d\u6b63\u78ba\u3060\u3068\u3001\u5b9f\u9a13\u304c\u5931\u6557\u3057\u305f\u308a\u518d\u73fe\u6027\u304c\u640d\u306a\u308f\u308c\u305f\u308a\u3059\u308b\u6050\u308c\u304c\u3042\u308a\u307e\u3059\u3002\u63a5\u7740\u6027\u306e\u57f9\u990a\u7d30\u80de\u3092\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u3059\u308b\u5834\u5408<\/p>\n","protected":false},"author":975,"featured_media":23768,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[97,23],"division":[],"class_list":{"0":"post-23765","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-cell","8":"tag-cell-count","9":"tag-cell-culture","10":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3051\u308b\u6b63\u78ba\u306a\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u91cd\u8981\u6027\u3068\u3001Hep G2\u306e\u3088\u3046\u306a\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u306e\u8a08\u6e2c\u65b9\u6cd5\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u305f\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u5b9f\u9a13\u306e\u518d\u73fe\u6027\u5411\u4e0a\u306e\u30d2\u30f3\u30c8\u306b\u304a\u5f79\u7acb\u3066\u304f\u3060\u3055\u3044\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f\" \/>\n<meta property=\"og:description\" content=\"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3051\u308b\u6b63\u78ba\u306a\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u91cd\u8981\u6027\u3068\u3001Hep G2\u306e\u3088\u3046\u306a\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u306e\u8a08\u6e2c\u65b9\u6cd5\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u305f\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u5b9f\u9a13\u306e\u518d\u73fe\u6027\u5411\u4e0a\u306e\u30d2\u30f3\u30c8\u306b\u304a\u5f79\u7acb\u3066\u304f\u3060\u3055\u3044\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-11-04T01:15:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-11-04T01:15:34+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1707\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"28\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f\",\"datePublished\":\"2025-11-04T01:15:28+00:00\",\"dateModified\":\"2025-11-04T01:15:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/\"},\"wordCount\":146,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/10\\\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg\",\"keywords\":[\"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8\",\"\u7d30\u80de\u57f9\u990a\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/\",\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/10\\\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg\",\"datePublished\":\"2025-11-04T01:15:28+00:00\",\"dateModified\":\"2025-11-04T01:15:34+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"description\":\"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3051\u308b\u6b63\u78ba\u306a\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u91cd\u8981\u6027\u3068\u3001Hep G2\u306e\u3088\u3046\u306a\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u306e\u8a08\u6e2c\u65b9\u6cd5\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u305f\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u5b9f\u9a13\u306e\u518d\u73fe\u6027\u5411\u4e0a\u306e\u30d2\u30f3\u30c8\u306b\u304a\u5f79\u7acb\u3066\u304f\u3060\u3055\u3044\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/10\\\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/10\\\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg\",\"width\":2560,\"height\":1707},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-culture-cell-count-bid-ts-mbr-25065\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f - Learning at the Bench","description":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3051\u308b\u6b63\u78ba\u306a\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u91cd\u8981\u6027\u3068\u3001Hep G2\u306e\u3088\u3046\u306a\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u306e\u8a08\u6e2c\u65b9\u6cd5\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u305f\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u5b9f\u9a13\u306e\u518d\u73fe\u6027\u5411\u4e0a\u306e\u30d2\u30f3\u30c8\u306b\u304a\u5f79\u7acb\u3066\u304f\u3060\u3055\u3044\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","og_description":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3051\u308b\u6b63\u78ba\u306a\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u91cd\u8981\u6027\u3068\u3001Hep G2\u306e\u3088\u3046\u306a\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u306e\u8a08\u6e2c\u65b9\u6cd5\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u305f\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u5b9f\u9a13\u306e\u518d\u73fe\u6027\u5411\u4e0a\u306e\u30d2\u30f3\u30c8\u306b\u304a\u5f79\u7acb\u3066\u304f\u3060\u3055\u3044\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-11-04T01:15:28+00:00","article_modified_time":"2025-11-04T01:15:34+00:00","og_image":[{"width":2560,"height":1707,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"28\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","datePublished":"2025-11-04T01:15:28+00:00","dateModified":"2025-11-04T01:15:34+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/"},"wordCount":146,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg","keywords":["\u7d30\u80de\u30ab\u30a6\u30f3\u30c8","\u7d30\u80de\u57f9\u990a"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg","datePublished":"2025-11-04T01:15:28+00:00","dateModified":"2025-11-04T01:15:34+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"description":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3051\u308b\u6b63\u78ba\u306a\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\u306e\u91cd\u8981\u6027\u3068\u3001Hep G2\u306e\u3088\u3046\u306a\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u306e\u8a08\u6e2c\u65b9\u6cd5\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u305f\u7d50\u679c\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\u5b9f\u9a13\u306e\u518d\u73fe\u6027\u5411\u4e0a\u306e\u30d2\u30f3\u30c8\u306b\u304a\u5f79\u7acb\u3066\u304f\u3060\u3055\u3044\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg","width":2560,"height":1707},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":97,"label":"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8"},{"value":23,"label":"\u7d30\u80de\u57f9\u990a"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-1024x683.jpg",760,507,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":103,"filter":"raw","meta":[],"cat_ID":159,"category_count":103,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":97,"name":"\u7d30\u80de\u30ab\u30a6\u30f3\u30c8","slug":"cell-count","term_group":0,"term_taxonomy_id":97,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]},{"term_id":23,"name":"\u7d30\u80de\u57f9\u990a","slug":"cell-culture","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":64,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/23765","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=23765"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/23765\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/23768"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=23765"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=23765"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=23765"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=23765"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}