{"id":24462,"date":"2025-12-17T15:59:44","date_gmt":"2025-12-17T06:59:44","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=24462"},"modified":"2026-02-20T14:01:32","modified_gmt":"2026-02-20T05:01:32","slug":"battery-development-microscopy-csm-25076","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","title":{"rendered":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u6cd5\u306f\u3001\u96fb\u6c60\u69cb\u6210\u8981\u7d20\u306e\u69cb\u9020\u304a\u3088\u3073\u7279\u6027\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306a\u77e5\u898b\u3092\u63d0\u4f9b\u3057\u3001\u3088\u308a\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3078\u306e\u9053\u3092\u5207\u308a\u958b\u304d\u307e\u3059\u3002<br>\u672c\u8a18\u4e8b\u3067\u306f\u3001\u5168\u56fa\u4f53\u96fb\u6c60\u7814\u7a76\u306b\u9769\u65b0\u3092\u3082\u305f\u3089\u3057\u3066\u3044\u308b\u3044\u304f\u3064\u304b\u306e\u5148\u9032\u7684\u306a\u8a55\u4fa1\u6280\u8853\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/blog\/materials\/exploring-advanced-characterization-techniques-for-solid-state-battery-innovation\/?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u539f\u6587\uff08\u82f1\u8a9e\uff09\uff1aExploring Advanced Characterization Techniques for Solid-State Battery Innovation<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u96fb\u5b50\u9855\u5fae\u93e1\">\u96fb\u5b50\u9855\u5fae\u93e1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. \u8d70\u67fb\u96fb\u5b50\u9855\u5fae\u93e1\uff08Scanning Electron Microscopy\uff1aSEM\uff09<br>SEM\u306f\u3001\u96fb\u6c60\u6750\u6599\u306e\u8868\u9762\u5f62\u614b\u304a\u3088\u3073\u69cb\u9020\u4e0a\u306e\u7279\u5fb4\u3092\u30df\u30af\u30ed\u30f3\u30ec\u30d9\u30eb\u3067\u89b3\u5bdf\u3059\u308b\u305f\u3081\u306e\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3067\u3059\u3002\u8a66\u6599\u306b\u96fb\u5b50\u3092\u7167\u5c04\u3057\u3001\u653e\u51fa\u3055\u308c\u308b\u4e8c\u6b21\u96fb\u5b50\u3084\u53cd\u5c04\u96fb\u5b50\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u3067\u3001SEM\u306f\u8868\u9762\u306e\u5f62\u72b6\u304a\u3088\u3073\u7d44\u6210\u3092\u660e\u3089\u304b\u306b\u3059\u308b\u9ad8\u89e3\u50cf\u5ea6\u753b\u50cf\u3092\u751f\u6210\u3057\u307e\u3059\u3002\u6b21\u4e16\u4ee3\u96fb\u6c60\u958b\u767a\u3067SEM\u304c\u6d3b\u7528\u3055\u308c\u308b\u4ee3\u8868\u7684\u306a\u4f8b\u3068\u3057\u3066\u3001\u6b63\u6975\u6d3b\u7269\u8cea\u8868\u9762\u306b\u65bd\u3055\u308c\u308b\u8584\u819c\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5c64\u306e\u89b3\u5bdf\u3068\u8a55\u4fa1\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0b\u306e\u56f31\u306f\u3001<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/electron-microscopy\/products\/scanning-electron-microscopes\/apreo-sem.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">Thermo Scientific\u2122 Apreo ChemiSEM\u2122<\/a> \u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u4f7f\u7528\u3057\u305f\u3001\u6975\u3081\u3066\u4f4e\u3044\u52a0\u901f\u96fb\u5727\uff08600 eV\uff09\u3067\u306eNMC\u6b63\u6975\u7c92\u5b50\u4e0a\u306e\u8d85\u8584\u819c\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306e\u89b3\u5bdf\u50cf\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-524f8de7 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"516\" height=\"345\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_1-2.jpg\" alt=\"\u56f31: NMC\u6b63\u6975\u7c92\u5b50\u306e600 eV\u53cd\u5c04\u96fb\u5b50\u50cf\uff08BSE\uff09\" class=\"wp-image-24476\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_1-2.jpg 516w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_1-2-300x201.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_1-2-96x65.jpg 96w\" sizes=\"auto, (max-width: 516px) 100vw, 516px\" \/><\/figure>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-524f8de7 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\">\u56f31: NMC\u6b63\u6975\u7c92\u5b50\u306e600 eV\u53cd\u5c04\u96fb\u5b50\u50cf\uff08BSE\uff09<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fbChemiSEM\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\uff1a<br>ChemiSEM\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u306f\u3001\u5f93\u6765\u306eSEM\u3092\u62e1\u5f35\u3057\u3001\u3088\u308a\u9ad8\u901f\u3067\u9ad8\u7cbe\u5ea6\u3001\u304b\u3064\u52b9\u7387\u7684\u306aEDS\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u9769\u65b0\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3059\u3002\u30e9\u30a4\u30d6\u30ab\u30e9\u30fc\u753b\u50cf\u306b\u3088\u3063\u3066\u5316\u5b66\u5143\u7d20\u3092\u8996\u899a\u7684\u306b\u533a\u5225\u3067\u304d\u308b\u305f\u3081\u3001\u8a66\u6599\u5185\u306e\u7570\u306a\u308b\u6750\u6599\u3092\u5373\u5ea7\u306b\u8b58\u5225\u3057\u3001\u8ffd\u52a0\u306e\u5206\u6790\u624b\u6cd5\u3092\u5fc5\u8981\u3068\u305b\u305a\u306b\u7d44\u6210\u306b\u95a2\u3059\u308b\u77e5\u898b\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3053\u308c\u306f\u3001ChemiSEM\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u304cSEM\u306b\u5b8c\u5168\u306b\u7d71\u5408\u3055\u308c\u5e38\u6642\u4f5c\u52d5\u3057\u3066\u3044\u308b\u305f\u3081\u5b9f\u73fe\u3067\u304d\u308b\u3053\u3068\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/materials-science\/battery-research\/technologies.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB#imaging-analysis\" target=\"_blank\" rel=\"noreferrer noopener\">\u8a73\u7d30\u306f\u3053\u3061\u3089\uff1a\u96fb\u6c60\u79d1\u5b66\u306b\u304a\u3051\u308bSEM\u6280\u8853<\/a><br><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/electron-microscopy\/products\/scanning-electron-microscopes.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u5f53\u793e\u306eSEM\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u8a73\u7d30<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. \u30c7\u30e5\u30a2\u30eb\u30d3\u30fc\u30e0\u96c6\u675f\u30a4\u30aa\u30f3\u30d3\u30fc\u30e0\uff08Focused Ion Beam\uff1aFIB\uff09-SEM\u30b7\u30b9\u30c6\u30e0<br>FIB\u3092SEM\u3068\u7d44\u307f\u5408\u308f\u305b\u305fDualBeam\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3068\u8a66\u6599\u52a0\u5de5\u3092\u540c\u6642\u306b\u5b9f\u884c\u3067\u304d\u308b\u88c5\u7f6e\u3067\u3059\u3002\u3053\u308c\u3089\u306f\u7279\u306b\u3001\u9ad8\u901f\u304b\u3064\u7279\u5b9a\u90e8\u4f4d\u306e\u65ad\u9762\u8a66\u6599\u306e\u4f5c\u88fd\u30013D\u6750\u6599\u7279\u6027\u8a55\u4fa1\u3001S\uff0fTEM\u30e9\u30e1\u30e9\u4f5c\u88fd\u306a\u3069\u306b\u6709\u7528\u3067\u3042\u308a\u3001\u96fb\u6c60\u90e8\u54c1\u306e\u5185\u90e8\u69cb\u9020\u3092\u7cbe\u5bc6\u306b\u89e3\u6790\u3067\u304d\u307e\u3059\u3002<br>\u56f32\u306f\u3001DualBeam\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308b\u65ad\u9762\u8a66\u6599\u306e\u4f5c\u88fd\u65b9\u6cd5\uff082a\uff09\u3068\u65ad\u9762\u52a0\u5de5\u3057\u305f\u56fa\u4f53\u96fb\u6c60\u6b63\u6975\u306e\u4f8b\uff082b\uff09\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-524f8de7 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"543\" height=\"208\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_2.jpg\" alt=\"\u56f32\uff1a2a \u2013 DualBeam\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308bFIB\u3068SEM\u8a66\u6599\u306e\u4f4d\u7f6e\u95a2\u4fc2\u306e\u6a21\u5f0f\u56f3\n2b \u2013 PFIB\u3067\u4f5c\u88fd\u3057\u305f\u56fa\u4f53\u96fb\u6c60\u6b63\u6975\u65ad\u9762\n\" class=\"wp-image-24477\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_2.jpg 543w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_2-300x115.jpg 300w\" sizes=\"auto, (max-width: 543px) 100vw, 543px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56f32\uff1a2a &#8211; DualBeam\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308bFIB\u3068SEM\u8a66\u6599\u306e\u4f4d\u7f6e\u95a2\u4fc2\u306e\u6a21\u5f0f\u56f3<br>2b &#8211; PFIB\u3067\u4f5c\u88fd\u3057\u305f\u56fa\u4f53\u96fb\u6c60\u6b63\u6975\u65ad\u9762<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fb\u30d7\u30e9\u30ba\u30deFIB\uff08PFIB\uff09\uff1a<br>PFIB\u3067\u306f\u3001\u30ad\u30bb\u30ce\u30f3\u3084\u30a2\u30eb\u30b4\u30f3\u306a\u3069\u306e\u4e0d\u6d3b\u6027\u5e0c\u30ac\u30b9\u3092\u4e00\u6b21\u30a4\u30aa\u30f3\u6e90\u3068\u3057\u3066\u4f7f\u7528\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u3088\u308a\u5927\u304d\u306a\u4f53\u7a4d\u306e\u6750\u6599\u3092\u89b3\u5bdf\u3067\u304d\u308b\u305f\u3081\u3001\u96fb\u6c60\u306e\u30d0\u30eb\u30af\u7279\u6027\u3084\u5927\u898f\u6a21\u69cb\u9020\u306e\u7814\u7a76\u306b\u975e\u5e38\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u4e0d\u6d3b\u6027\u30ac\u30b9\u3092\u4e00\u6b21\u30a4\u30aa\u30f3\u6e90\u3068\u3057\u3066\u7528\u3044\u308b\u3053\u3068\u3067\u3001\u30ea\u30c1\u30a6\u30e0\u542b\u6709\u6750\u6599\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u308b\u3068\u3044\u3046\u5229\u70b9\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fb\u30ac\u30ea\u30a6\u30e0FIB\uff1a<br>\u4e00\u65b9\u3001\u30ac\u30ea\u30a6\u30e0FIB\u306f\u5fae\u7d30\u69cb\u9020\u3084\u754c\u9762\u306e\u9ad8\u5206\u89e3\u80fd\u89b3\u5bdf\u306b\u9069\u3057\u3066\u304a\u308a\u3001\u3088\u308a\u5c0f\u3055\u306a\u30b9\u30b1\u30fc\u30eb\u3067\u306e\u8a73\u7d30\u89e3\u6790\u306b\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30ac\u30ea\u30a6\u30e0\u3068\u30ea\u30c1\u30a6\u30e0\u304c\u5ba4\u6e29\u3067\u5f37\u304f\u76f8\u4e92\u4f5c\u7528\u3059\u308b\u305f\u3081\u3001\u30ea\u30c1\u30a6\u30e0\u3092\u542b\u3080\u69cb\u9020\u306b\u308f\u305a\u304b\u306a\u5909\u5316\u3092\u5f15\u304d\u8d77\u3053\u3059\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/materials-science\/battery-research\/technologies.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB#multi-modal-analysis\" target=\"_blank\" rel=\"noreferrer noopener\">\u8a73\u7d30\u306f\u3053\u3061\u3089\uff1a\u96fb\u6c60\u79d1\u5b66\u306b\u304a\u3051\u308bDualBeam\u6280\u8853<\/a><br><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/electron-microscopy\/products\/dualbeam-fib-sem-microscopes.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u5f53\u793e\u306eDualBeam\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u8a73\u7d30<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fb\u900f\u904e\u96fb\u5b50\u9855\u5fae\u93e1\uff08Transmission Electron Microscopy\uff1aTEM\uff09<br>TEM\u306f\u3001\u30b5\u30d6\u30ca\u30ce\u30e1\u30fc\u30c8\u30eb\u30b9\u30b1\u30fc\u30eb\u306e\u9ad8\u5206\u89e3\u80fd\u306a\u69cb\u9020\u89e3\u6790\u3092\u53ef\u80fd\u306b\u3057\u3001\u539f\u5b50\u30ec\u30d9\u30eb\u3067\u306e\u6319\u52d5\u306e\u89e3\u660e\u306b\u8ca2\u732e\u3057\u307e\u3059\u3002TEM\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u79d1\u5b66\u8005\u3084\u6280\u8853\u8005\u306f\u539f\u5b50\u914d\u5217\u3084\u7d50\u6676\u69cb\u9020\u3068\u3044\u3063\u305f\u5fae\u7d30\u306a\u69cb\u9020\u60c5\u5831\u3092\u53d6\u5f97\u3057\u3001TEM\u4ee5\u5916\u306e\u5206\u6790\u624b\u6cd5\u3067\u306f\u7406\u89e3\u3057\u306b\u304f\u3044\u69cb\u9020\u3068\u6a5f\u80fd\u6027\u306e\u95a2\u4fc2\u3092\u7406\u89e3\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u96fb\u6c60\u6750\u6599\u306e\u5206\u6790\u3067\u306f\u3001TEM\uff08\u9ad8\u5206\u89e3\u80fd\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3001\u96fb\u5b50\u56de\u6298\u3001EDS\u3001EELS\u306a\u3069\uff09\u306f\u3001\u5f62\u614b\u30fb\u7d50\u6676\u69cb\u9020\u30fb\u5316\u5b66\u60c5\u5831\u306b\u95a2\u3059\u308b\u8cb4\u91cd\u306a\u30c7\u30fc\u30bf\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002\u7279\u306b\u3001\u56fa\u4f53\u96fb\u89e3\u8cea\u754c\u9762\uff08Solid Electrolyte Interphase\uff1aSEI\uff09\u306e\u3088\u3046\u306a\u96fb\u5b50\u7dda\u306b\u654f\u611f\u306a\u6750\u6599\u306e\u30ca\u30ce\u30b9\u30b1\u30fc\u30eb\u8a55\u4fa1\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002SEI\u5c64\u306e\u7d44\u6210\u3068\u69cb\u9020\u3092\u660e\u3089\u304b\u306b\u3059\u308b\u3053\u3068\u306f\u3001\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u306e\u96fb\u6975\u3078\u306e\u51fa\u5165\u308a\u306e\u6319\u52d5\u3092\u7406\u89e3\u3059\u308b\u4e0a\u3067\u91cd\u8981\u3067\u3042\u308a\u3001\u30b5\u30a4\u30af\u30eb\u3092\u91cd\u306d\u308b\u306b\u3064\u308c\u3066\u5bb9\u91cf\u4fdd\u6301\u7387\u304c\u4f4e\u4e0b\u3059\u308b\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u628a\u63e1\u3059\u308b\u52a9\u3051\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u3046\u3057\u305f\u77e5\u898b\u306f\u3001\u6b21\u4e16\u4ee3\u96fb\u6c60\u306e\u958b\u767a\u3084\u52a3\u5316\u30fb\u6545\u969c\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u89e3\u660e\u306b\u6b20\u304b\u305b\u307e\u305b\u3093\u3002\u56f33\u3067\u306f\u3001TEM\u3092\u7528\u3044\u3066\u30ea\u30c1\u30a6\u30e0\u91d1\u5c5e\u8a66\u6599\u3092\u89b3\u5bdf\u3057\u305f\u69d8\u5b50\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-524f8de7 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"574\" height=\"259\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_3.jpg\" alt=\"\u56f33\uff1a3a \u2013 HAADF\u691c\u51fa\u5668\u3092\u7528\u3044\u305f200 keV\u3067\u306e\u30ea\u30c1\u30a6\u30e0\u91d1\u5c5e\u306e\u4f4e\u500d\u7387\u50cf\n3b \u2013 \u30ea\u30c1\u30a6\u30e0\u683c\u5b50\u69cb\u9020\u306e\u9ad8\u5206\u89e3\u80fdTEM\u50cf\" class=\"wp-image-24479\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_3.jpg 574w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_3-300x135.jpg 300w\" sizes=\"auto, (max-width: 574px) 100vw, 574px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56f33\uff1a3a &#8211; HAADF\u691c\u51fa\u5668\u3092\u7528\u3044\u305f200 keV\u3067\u306e\u30ea\u30c1\u30a6\u30e0\u91d1\u5c5e\u306e\u4f4e\u500d\u7387\u50cf<br>3b &#8211; \u30ea\u30c1\u30a6\u30e0\u683c\u5b50\u69cb\u9020\u306e\u9ad8\u5206\u89e3\u80fdTEM\u50cf<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/materials-science\/battery-research\/technologies.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB#atomic-scale-imaging-analysis\" target=\"_blank\" rel=\"noreferrer noopener\">\u8a73\u7d30\u306f\u3053\u3061\u3089\uff1a\u96fb\u6c60\u79d1\u5b66\u306b\u304a\u3051\u308bTEM\u6280\u8853<\/a><br><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/electron-microscopy\/products\/transmission-electron-microscopes\/instruments.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u5f53\u793e\u306eTEM\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u8a73\u7d30<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-x\u7dda\u5149\u96fb\u5b50\u5206\u5149\u6cd5-x-ray-photoelectron-spectroscopy-xps\">X\u7dda\u5149\u96fb\u5b50\u5206\u5149\u6cd5\uff08X-ray Photoelectron Spectroscopy\uff1aXPS\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">XPS\u306f\u3001\u8a66\u6599\u8868\u9762\u306e\u6700\u8868\u5c64\u306b\u304a\u3051\u308b\u5143\u7d20\u7d44\u6210\u30fb\u96fb\u5b50\u72b6\u614b\u30fb\u5316\u5b66\u7d50\u5408\u72b6\u614b\u3092\u5b9a\u91cf\u7684\u306b\u5206\u6790\u3067\u304d\u308b\u8868\u9762\u5206\u6790\u6280\u8853\u3067\u3059\u3002\u96fb\u6c60\u5206\u91ce\u3067\u306f\u3001\u754c\u9762\u53cd\u5fdc\u3001\u8868\u9762\u6c5a\u67d3\u3001SEI\u5f62\u6210\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u89e3\u660e\u306a\u3069\u306b\u6709\u52b9\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u30ea\u30c1\u30a6\u30e0\u30a4\u30aa\u30f3\u96fb\u6c60\u306e\u6b63\u6975\u30fb\u8ca0\u6975\u6750\u6599\u3092\u5206\u6790\u3057\u3001\u30b5\u30a4\u30af\u30eb\u5f8c\u306e\u7d44\u6210\u5909\u5316\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3067\u3001\u96fb\u6975\u306e\u5316\u5b66\u5909\u5316\u3084SEI\u5c64\u306e\u6df1\u3055\u65b9\u5411\u306e\u6210\u9577\u3092\u7406\u89e3\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001XPS\u306f\u9ed2\u925b\u96fb\u6975\u6750\u6599\u8868\u9762\u306e\u524d\u51e6\u7406\u306b\u3088\u3063\u3066\u3001\u5145\u653e\u96fb\u4e2d\u306e\u4e0d\u53ef\u9006\u7684\u306a\u96fb\u6975\u640d\u8017\u3092\u6291\u5236\u3059\u308b\u7814\u7a76\u306b\u3082\u5fdc\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u56f34\u306f\u3001\u65b0\u54c1\uff08\u9752\uff09\u3068\u30b5\u30a4\u30af\u30eb\u5f8c\uff08\u8d64\uff09\u306e\u6b63\u6975\u6d3b\u7269\u8cea\u306e\u5316\u5b66\u5909\u5316\u3092\u793a\u3059XPS\u306b\u3088\u308b\u5206\u6790\u7d50\u679c\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-524f8de7 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"597\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_4-768x597-1.jpg\" alt=\"\u56f34\uff1a \u65b0\u54c1\u306e\u6b63\u6975\uff08\u9752\uff09\u3068\u30b5\u30a4\u30af\u30eb\u5f8c\u306e\u6b63\u6975\uff08\u8d64\uff09\u306e\u30b9\u30da\u30af\u30c8\u30eb\" class=\"wp-image-24482\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_4-768x597-1.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_4-768x597-1-300x233.jpg 300w\" sizes=\"auto, (max-width: 768px) 100vw, 768px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56f34\uff1a \u65b0\u54c1\u306e\u6b63\u6975\uff08\u9752\uff09\u3068\u30b5\u30a4\u30af\u30eb\u5f8c\u306e\u6b63\u6975\uff08\u8d64\uff09\u306e\u30b9\u30da\u30af\u30c8\u30eb<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/materials-science\/battery-research\/technologies.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB#xps-surface-analysis\" target=\"_blank\" rel=\"noreferrer noopener\">\u8a73\u7d30\u306f\u3053\u3061\u3089\uff1a\u96fb\u6c60\u79d1\u5b66\u306b\u304a\u3051\u308bXPS\u6280\u8853<\/a><br><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/electron-microscopy\/products\/xps-instruments\/instruments.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u5f53\u793e\u306eXPS\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u8a73\u7d30<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u753b\u50cf\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\">\u753b\u50cf\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1. \u751f\u30c7\u30fc\u30bf\u304b\u3089\u77e5\u898b\u3092\u751f\u307f\u51fa\u3059<br>\u5148\u9032\u7684\u306a\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u6280\u8853\u306f\u81a8\u5927\u306a\u30c7\u30fc\u30bf\u3092\u751f\u6210\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u30c7\u30fc\u30bf\u3092\u6709\u52b9\u6d3b\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u753b\u50cf\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u3002\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3088\u3063\u3066\u30c7\u30fc\u30bf\u3092\u51e6\u7406\u30fb\u53ef\u8996\u5316\u3057\u3001\u6750\u6599\u7279\u6027\u306b\u95a2\u3059\u308b\u5b9a\u91cf\u7684\u306a\u77e5\u898b\u3092\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30fb3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\uff1a<br>Thermo Scientific\u2122 Avizo\u2122 \u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306e\u3088\u3046\u306a\u30c4\u30fc\u30eb\u3067\u306f\u3001\u6750\u6599\u69cb\u9020\u30922D\u304a\u3088\u30733D\u306e\u4e21\u9762\u304b\u3089\u89e3\u6790\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u88fd\u9020\u30d7\u30ed\u30bb\u30b9\u306e\u54c1\u8cea\u8a55\u4fa1\u52a3\u5316\u5206\u6790\u3001\u96fb\u6975\u5185\u90e8\u306e\u63a5\u7d9a\u6027\u3084\u66f2\u8def\u7387\u306e\u7406\u89e3\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. \u5b9a\u91cf\u7684\u89e3\u6790<br><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/electron-microscopy\/products\/software-em-3d-vis\/avizo-software\/avizo-trueput-software-battery-quality-control.html?icid=CAD_blog_materials_2025June&amp;CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">Thermo Scientific\u2122 Avizo Trueput\u2122 \u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/a>\u306e\u3088\u3046\u306a\u89e3\u6790\u30c4\u30fc\u30eb\u3067\u306f\u3001\u96fb\u6975\u6750\u6599\u3084\u30bb\u30eb\u5168\u4f53\u306b\u542b\u307e\u308c\u308b\u8907\u96d1\u306a\u69cb\u9020\u3092\u7279\u5b9a\u3057\u3001\u7a7a\u9699\u5f84\u30fb\u5206\u5e03\u30fb\u63a5\u7d9a\u6027\u3068\u3044\u3063\u305f\u7279\u6027\u3092\u5b9a\u91cf\u7684\u306b\u6e2c\u5b9a\u3067\u304d\u307e\u3059\u3002<br>\u3053\u308c\u3089\u306e\u7d50\u679c\u3092\u96fb\u6c60\u6027\u80fd\u6307\u6a19\u3068\u76f8\u95a2\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u69cb\u9020\u7279\u6027\u3068\u96fb\u6c60\u6027\u80fd\u306e\u95a2\u4fc2\u3092\u660e\u78ba\u306b\u3057\u3001\u8a2d\u8a08\u6539\u826f\u3078\u3068\u3064\u306a\u3052\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-524f8de7 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"519\" height=\"344\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_5.jpg\" alt=\"\u56f35\uff1a Avizo Trueput\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3088\u3063\u3066\u7c92\u5b50\u5272\u308c\u3092\u30bb\u30b0\u30e1\u30f3\u30c8\u5316\u3057\u305fNMC\u6b63\u6975\u65ad\u9762\u306e\u4f8b\n\n\" class=\"wp-image-24484\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_5.jpg 519w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_5-300x199.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_BatteryCharacterization_5-96x65.jpg 96w\" sizes=\"auto, (max-width: 519px) 100vw, 519px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56f35\uff1a Avizo Trueput\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306b\u3088\u3063\u3066\u7c92\u5b50\u5272\u308c\u3092\u30bb\u30b0\u30e1\u30f3\u30c8\u5316\u3057\u305fNMC\u6b63\u6975\u65ad\u9762\u306e\u4f8b<\/p>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">3. \u4e88\u6e2c\u30e2\u30c7\u30ea\u30f3\u30b0<br>\u3055\u3089\u306b\u3001\u4e00\u90e8\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306f\u3001\u4e88\u6e2c\u30e2\u30c7\u30ea\u30f3\u30b0\u3092\u901a\u3058\u3066\u3001\u6750\u6599\u304c\u3055\u307e\u3056\u307e\u306a\u6761\u4ef6\u4e0b\u3067\u3069\u306e\u3088\u3046\u306b\u6319\u52d5\u3059\u308b\u304b\u3092\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u69cb\u9020\u3084\u7d44\u6210\u306e\u5909\u5316\u304c\u96fb\u6c60\u6027\u80fd\u306b\u53ca\u307c\u3059\u5f71\u97ff\u3092\u4e8b\u524d\u306b\u4e88\u6e2c\u3067\u304d\u3001\u6700\u9069\u5316\u3084\u958b\u767a\u306e\u52a0\u901f\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/electron-microscopy\/products\/software-em-3d-vis\/avizo-software\/batteries.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u8a73\u7d30\u306f\u3053\u3061\u3089\uff1aAvizo\u306b\u3088\u308b\u96fb\u6c60\u79d1\u5b66\u5411\u3051\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5148\u7aef\u7684\u306a\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306f\u3001\u5168\u56fa\u4f53\u96fb\u6c60\u7814\u7a76\u3092\u5927\u304d\u304f\u524d\u9032\u3055\u305b\u3001\u96fb\u6c60\u5185\u90e8\u306e\u6750\u6599\u3084\u305d\u306e\u76f8\u4e92\u4f5c\u7528\u306b\u95a2\u3059\u308b\u6df1\u3044\u7406\u89e3\u3092\u53ef\u80fd\u306b\u3057\u3066\u3044\u307e\u3059\u3002SEM\u3001TEM\u3001FIB\u3001XPS\u3068\u3044\u3063\u305f\u5206\u6790\u624b\u6cd5\u3068\u3001\u9ad8\u5ea6\u306a\u753b\u50cf\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u7814\u7a76\u8005\u306f\u96fb\u6c60\u6750\u6599\u3092\u6700\u9069\u5316\u3057\u3001\u6027\u80fd\u3068\u5b89\u5168\u6027\u306e\u4e21\u7acb\u3092\u56f3\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u5206\u6790\u624b\u6cd5\u306b\u3064\u3044\u3066\u306e\u3088\u308a\u8a73\u7d30\u306a\u60c5\u5831\u63d0\u4f9b\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u305c\u3072\u5f53\u793e\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/industrial\/green-energy-battery-join-our-community-registration-form.html?erpType=Global_E1&amp;CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u304a\u554f\u3044\u5408\u308f\u305b\u30d5\u30a9\u30fc\u30e0<\/a>\u3088\u308a\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u3053\u308c\u3089\u4ee5\u5916\u306e\u96fb\u6c60\u7814\u7a76\u958b\u767a\u30fb\u88fd\u9020\u6642\u306e\u5206\u6790\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u306f\u3001\u5f53\u793e\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/industrial\/battery.html?CID=csm_cdi_r04_jp_cp0000_pjt0000_csm00000_0so_blg_battery_development_microscopy_csm_25076_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">\u96fb\u6c60\u5206\u6790\u30c8\u30c3\u30d7\u30da\u30fc\u30b8<\/a>\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7a3f\u306e\u4f5c\u6210\u306b\u3042\u305f\u308a\u3001\u4ee5\u4e0b\u306e\u7814\u7a76\u8005\u306e\u5354\u529b\u306b\u611f\u8b1d\u3044\u305f\u3057\u307e\u3059\u3002<br>Dr. Chengge Jiao\u3001Dr. Eric Goergen\u3001Dr. Lin Jiang\u3001Dr. Letian Li\u3001Dr. Zhao Liu\u3001Dr. Maria Meledina\u3001Dr. Tim Nunney\u3001Dr. Luigi Raspolini<\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u958b\u767a\u3067\u306f\u3001\u4f7f\u7528\u3055\u308c\u308b\u6750\u6599\u306e\u7406\u89e3\u3092\u6df1\u3081\u308b\u305f\u3081\u306b\u3001\u5148\u7aef\u7684\u306a\u6027\u8a55\u4fa1\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u624b\u6cd5\u306f\u3001\u96fb\u6c60\u69cb\u6210\u8981\u7d20\u306e\u69cb\u9020\u304a\u3088\u3073\u7279\u6027\u306b\u95a2\u3059\u308b\u8a73\u7d30\u306a\u77e5\u898b\u3092\u63d0\u4f9b\u3057\u3001\u3088\u308a\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3078\u306e\u9053\u3092\u5207\u308a<\/p>\n","protected":false},"author":975,"featured_media":24463,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[249,236,245],"division":[],"class_list":["post-24462","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-clean-energy","tag-battery-development","tag-microscopy","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u6750\u6599\u7406\u89e3\u306b\u4e0d\u53ef\u6b20\u306a\u5148\u7aef\u8a55\u4fa1\u6280\u8853\u3092\u89e3\u8aac\u3057\u3001\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u306e\u5b9f\u73fe\u306b\u5411\u3051\u305f\u7814\u7a76\u52d5\u5411\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76\" \/>\n<meta property=\"og:description\" content=\"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u6750\u6599\u7406\u89e3\u306b\u4e0d\u53ef\u6b20\u306a\u5148\u7aef\u8a55\u4fa1\u6280\u8853\u3092\u89e3\u8aac\u3057\u3001\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u306e\u5b9f\u73fe\u306b\u5411\u3051\u305f\u7814\u7a76\u52d5\u5411\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-17T06:59:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-20T05:01:32+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2048\" \/>\n\t<meta property=\"og:image:height\" content=\"1536\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"21\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76\",\"datePublished\":\"2025-12-17T06:59:44+00:00\",\"dateModified\":\"2026-02-20T05:01:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/\"},\"wordCount\":140,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/12\\\/battery-development-microscopy-csm-25076_eyecatch.jpg\",\"keywords\":[\"\u30af\u30ea\u30fc\u30f3\u30a8\u30ca\u30b8\u30fc\",\"\u96fb\u6c60\u958b\u767a\",\"\u9855\u5fae\u93e1\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/\",\"name\":\"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/12\\\/battery-development-microscopy-csm-25076_eyecatch.jpg\",\"datePublished\":\"2025-12-17T06:59:44+00:00\",\"dateModified\":\"2026-02-20T05:01:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"description\":\"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u6750\u6599\u7406\u89e3\u306b\u4e0d\u53ef\u6b20\u306a\u5148\u7aef\u8a55\u4fa1\u6280\u8853\u3092\u89e3\u8aac\u3057\u3001\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u306e\u5b9f\u73fe\u306b\u5411\u3051\u305f\u7814\u7a76\u52d5\u5411\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/12\\\/battery-development-microscopy-csm-25076_eyecatch.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2025\\\/12\\\/battery-development-microscopy-csm-25076_eyecatch.jpg\",\"width\":2048,\"height\":1536},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/battery-development-microscopy-csm-25076\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76 - Learning at the Bench","description":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u6750\u6599\u7406\u89e3\u306b\u4e0d\u53ef\u6b20\u306a\u5148\u7aef\u8a55\u4fa1\u6280\u8853\u3092\u89e3\u8aac\u3057\u3001\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u306e\u5b9f\u73fe\u306b\u5411\u3051\u305f\u7814\u7a76\u52d5\u5411\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","og_locale":"ja_JP","og_type":"article","og_title":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","og_description":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u6750\u6599\u7406\u89e3\u306b\u4e0d\u53ef\u6b20\u306a\u5148\u7aef\u8a55\u4fa1\u6280\u8853\u3092\u89e3\u8aac\u3057\u3001\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u306e\u5b9f\u73fe\u306b\u5411\u3051\u305f\u7814\u7a76\u52d5\u5411\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2025-12-17T06:59:44+00:00","article_modified_time":"2026-02-20T05:01:32+00:00","og_image":[{"width":2048,"height":1536,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"21\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76","datePublished":"2025-12-17T06:59:44+00:00","dateModified":"2026-02-20T05:01:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/"},"wordCount":140,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg","keywords":["\u30af\u30ea\u30fc\u30f3\u30a8\u30ca\u30b8\u30fc","\u96fb\u6c60\u958b\u767a","\u9855\u5fae\u93e1"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/","name":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg","datePublished":"2025-12-17T06:59:44+00:00","dateModified":"2026-02-20T05:01:32+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"description":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u6750\u6599\u7406\u89e3\u306b\u4e0d\u53ef\u6b20\u306a\u5148\u7aef\u8a55\u4fa1\u6280\u8853\u3092\u89e3\u8aac\u3057\u3001\u9ad8\u52b9\u7387\u3067\u5b89\u5168\u306a\u30a8\u30cd\u30eb\u30ae\u30fc\u8caf\u8535\u306e\u5b9f\u73fe\u306b\u5411\u3051\u305f\u7814\u7a76\u52d5\u5411\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg","width":2048,"height":1536},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-microscopy-csm-25076\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u5168\u56fa\u4f53\u96fb\u6c60\u306e\u9769\u65b0\u3092\u652f\u3048\u308b\u5148\u7aef\u7684\u7279\u6027\u8a55\u4fa1\u6280\u8853\u306e\u63a2\u7a76"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":249,"label":"\u30af\u30ea\u30fc\u30f3\u30a8\u30ca\u30b8\u30fc"},{"value":236,"label":"\u96fb\u6c60\u958b\u767a"},{"value":245,"label":"\u9855\u5fae\u93e1"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch-1024x768.jpg",760,570,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":249,"name":"\u30af\u30ea\u30fc\u30f3\u30a8\u30ca\u30b8\u30fc","slug":"clean-energy","term_group":0,"term_taxonomy_id":249,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw","meta":[]},{"term_id":236,"name":"\u96fb\u6c60\u958b\u767a","slug":"battery-development","term_group":0,"term_taxonomy_id":236,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]},{"term_id":245,"name":"\u9855\u5fae\u93e1","slug":"microscopy","term_group":0,"term_taxonomy_id":245,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/battery-development-microscopy-csm-25076_eyecatch.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/24462","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=24462"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/24462\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/24463"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=24462"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=24462"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=24462"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=24462"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}