{"id":24647,"date":"2026-02-09T18:08:40","date_gmt":"2026-02-09T09:08:40","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=24647"},"modified":"2026-02-09T18:08:43","modified_gmt":"2026-02-09T09:08:43","slug":"sanger-seq-mutational-analysis-gsd-ts-ce-26007","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","title":{"rendered":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2"},"content":{"rendered":"\n<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u7570\u691c\u51fa\u306f\u6975\u3081\u3066\u56f0\u96e3\u3067\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u816b\u760d\u5b66\u3084\u611f\u67d3\u75c7\u5b66\u306a\u3069\u306e\u7814\u7a76\u5206\u91ce\u306b\u304a\u3044\u3066\u3001\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u306f\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002<br>\u305d\u3053\u3067\u4eca\u56de\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30c7\u30fc\u30bf\u3067\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u305f\u3081\u306b\u958b\u767a\u3055\u308c\u305fApplied Biosystems\u2122 <a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-dna-sequencing\/sanger-sequencing-data-analysis\/minor-variant-finder-software.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_mutational_analysis_gsd_ts_ce_26007_Social_LAB\" target=\"_blank\" rel=\"noreferrer noopener\">Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2<\/a>\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u25bc\u3053\u3093\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br>\u30fb\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u89e3\u6790\u3057\u305f\u3044\u65b9<br>\u30fb\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5\uff08NGS\uff09\u3067\u691c\u51fa\u3057\u305f\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u78ba\u8a8d\u3057\u305f\u3044\u65b9<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bminor-variant-finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3068\u306f\">\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3068\u306f\uff1f<\/h2>\n\n\n\n<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30c7\u30fc\u30bf\u306b\u306f\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306b\u30ce\u30a4\u30ba\u304c\u751f\u3058\u307e\u3059\u3002\u5909\u7570\u306e\u5272\u5408\u304c\u4f4e\u3044\u5834\u5408\u306f\u5909\u7570\u30d4\u30fc\u30af\u304c\u5c0f\u3055\u304f\u3001\u30ce\u30a4\u30ba\u306b\u57cb\u3082\u308c\u3066\u3057\u307e\u3044\u3001\u30ce\u30a4\u30ba\u3068\u5909\u7570\u30d4\u30fc\u30af\u3092\u898b\u5206\u3051\u308b\u3053\u3068\u304c\u56f0\u96e3\u306b\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u5f93\u6765\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3067\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u306b\u306f\u300125\uff05\u7a0b\u5ea6\u4ee5\u4e0a\u306e\u5272\u5408\u3067\u5909\u7570\u30d4\u30fc\u30af\u304c\u5b58\u5728\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3057\u305f\u3002<br>Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u3001\u5f53\u793e\u306e\u9577\u5e74\u306b\u308f\u305f\u308b\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u6280\u8853\u306e\u84c4\u7a4d\u3092\u57fa\u306b\u958b\u767a\u3057\u305f\u9769\u65b0\u7684\u306a\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3092\u642d\u8f09\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u306b\u3088\u308a\u3001\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u30ce\u30a4\u30ba\u304c\u8b58\u5225\u3055\u308c\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u30b5\u30f3\u30d7\u30eb\u306e\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3059\u308b\u30d7\u30ed\u30bb\u30b9\u304c\u884c\u308f\u308c\u307e\u3059\u3002\u3053\u306e\u7d50\u679c\u3001\u8b58\u5225\u304c\u56f0\u96e3\u306a\u30de\u30a4\u30ca\u30fc\u5909\u7570\u306e\u30d4\u30fc\u30af\u3092\u8996\u899a\u7684\u306b\u6349\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u30d5\u30a9\u30ef\u30fc\u30c9\u304a\u3088\u3073\u30ea\u30d0\u30fc\u30b9\u914d\u5217\u306e\u4e21\u65b9\u306e\u30c7\u30fc\u30bf\u304b\u3089\u5909\u7570\u306e\u691c\u51fa\u3092\u884c\u3046\u3053\u3068\u3067\u3001\u30de\u30a4\u30ca\u30fc\u5909\u7570\uff085%\u7a0b\u5ea6\uff09\u306e\u691c\u51fa\u3092\u53ef\u80fd\u306b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"520\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/795316b92fc766b0181f6fef074f03fa-1024x520.jpg\" alt=\"\u56f31. \u30aa\u30ea\u30b8\u30ca\u30eb\u30c7\u30fc\u30bf\uff08\u4e0a\u6bb5\uff09\u3068Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u89e3\u6790\u3057\u305f\u30c7\u30fc\u30bf\uff08\u4e0b\u6bb5\uff09\" class=\"wp-image-24659\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/795316b92fc766b0181f6fef074f03fa-1024x520.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/795316b92fc766b0181f6fef074f03fa-300x152.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/795316b92fc766b0181f6fef074f03fa-768x390.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/795316b92fc766b0181f6fef074f03fa.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56f31. \u30aa\u30ea\u30b8\u30ca\u30eb\u30c7\u30fc\u30bf\uff08\u4e0a\u6bb5\uff09\u3068Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u89e3\u6790\u3057\u305f\u30c7\u30fc\u30bf\uff08\u4e0b\u6bb5\uff09<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u30b7\u30f3\u30d7\u30eb\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3067\u5909\u7570\u3092\u691c\u51fa\">\u30b7\u30f3\u30d7\u30eb\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3067\u5909\u7570\u3092\u691c\u51fa\uff01<\/h2>\n\n\n\n<p>Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u89e3\u6790\u3059\u308b\u305f\u3081\u306b\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u5909\u66f4\u3059\u308b\u5fc5\u8981\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u7279\u5225\u306a\u8a66\u85ac\u3092\u4f7f\u7528\u3057\u305f\u308a\u3001\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u5909\u66f4\u3057\u305f\u308a\u3059\u308b\u3053\u3068\u306a\u304f\u3001\u5f53\u793e\u306e\u30b8\u30a7\u30cd\u30c6\u30a3\u30c3\u30af\u30a2\u30ca\u30e9\u30a4\u30b6\u3067\u53d6\u5f97\u3057\u305f\u30b7\u30fc\u30b1\u30f3\u30b9\u30c7\u30fc\u30bf\u30d5\u30a1\u30a4\u30eb\u3092\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u89e3\u6790\u3044\u305f\u3060\u3051\u307e\u3059\u3002<br>\u6ce8\u610f\u4e8b\u9805\uff1a \u89e3\u6790\u3067\u304d\u306a\u3044\u6a5f\u7a2e\u304c\u3054\u3056\u3044\u307e\u3059\u306e\u3067\u3001\u89e3\u6790\u306e\u524d\u306b\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"204\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/2b530e80c7d0de90885e285c5d798063-1024x204.jpg\" alt=\"\u56f32. \u89e3\u6790\u30d5\u30ed\u30fc\" class=\"wp-image-24662\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/2b530e80c7d0de90885e285c5d798063-1024x204.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/2b530e80c7d0de90885e285c5d798063-300x60.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/2b530e80c7d0de90885e285c5d798063-768x153.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/2b530e80c7d0de90885e285c5d798063-1536x306.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/2b530e80c7d0de90885e285c5d798063.jpg 1700w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56f32. \u89e3\u6790\u30d5\u30ed\u30fc<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong>Step 1\uff1a\u30b5\u30f3\u30d7\u30eb\u3092\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0<\/strong><br>\u30bf\u30fc\u30b2\u30c3\u30c8\u30b5\u30f3\u30d7\u30eb\u3068\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u3092\u3001\u30d5\u30a9\u30ef\u30fc\u30c9\u30d7\u30e9\u30a4\u30de\u30fc\u3068\u30ea\u30d0\u30fc\u30b9\u30d7\u30e9\u30a4\u30de\u30fc\u3067\u305d\u308c\u305e\u308c\u30b7\u30fc\u30b1\u30f3\u30b7\u30f3\u30b0\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p>\u6ce8\u610f\u4e8b\u9805\uff1a\u3053\u308c\u3089\u306e\u30b5\u30f3\u30d7\u30eb\u306f\u5168\u3066\u540c\u3058\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u306b\u3066\u30e9\u30f3\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u7570\u306a\u308b\u30a4\u30f3\u30b8\u30a7\u30af\u30b7\u30e7\u30f3\u306e\u5834\u5408\u3001\u30ce\u30a4\u30ba\u306e\u6700\u5c0f\u5316\u30d7\u30ed\u30bb\u30b9\u306b\u5f71\u97ff\u3057\u3001\u9069\u5207\u306b\u89e3\u6790\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p><strong>Step 2\uff1aMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u7c21\u5358\u306b\u89e3\u6790<\/strong><br>Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u3092\u4f5c\u6210\u3057\u305f\u5f8c\u3001\u30b7\u30fc\u30b1\u30f3\u30b9\u30c7\u30fc\u30bf\u3092\u6307\u5b9a\u3057\u3066\u89e3\u6790\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002<br>\u89e3\u6790\u5f8c\u306f\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3057\u305f\u30bf\u30fc\u30b2\u30c3\u30c8\u30b5\u30f3\u30d7\u30eb\u306e\u6ce2\u5f62\u3084\u3001\u691c\u51fa\u3055\u308c\u305f\u5909\u7570\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"376\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/c8856789ec11ab8b1013037cef6929f9-1024x376.jpg\" alt=\"\u56f33. Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306e\u89e3\u6790\u7d50\u679c\" class=\"wp-image-24663\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/c8856789ec11ab8b1013037cef6929f9-1024x376.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/c8856789ec11ab8b1013037cef6929f9-300x110.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/c8856789ec11ab8b1013037cef6929f9-768x282.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/c8856789ec11ab8b1013037cef6929f9.jpg 1236w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56f33. Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306e\u89e3\u6790\u7d50\u679c<\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:0px\" aria-hidden=\"true\" class=\"wp-block-spacer wp-container-content-cf2db169\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"425\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/3a4f695a458cb0ac0aceaa2eb13ac2dd-1024x425.jpg\" alt=\"\u56f34. Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306e\u89e3\u6790\u7d50\u679c\uff1a\u6ce2\u5f62\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d\" class=\"wp-image-24664\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/3a4f695a458cb0ac0aceaa2eb13ac2dd-1024x425.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/3a4f695a458cb0ac0aceaa2eb13ac2dd-300x125.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/3a4f695a458cb0ac0aceaa2eb13ac2dd-768x319.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/3a4f695a458cb0ac0aceaa2eb13ac2dd-1536x637.jpg 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/3a4f695a458cb0ac0aceaa2eb13ac2dd-2048x850.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56f34. Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3067\u306e\u89e3\u6790\u7d50\u679c\uff1a\u6ce2\u5f62\u30c7\u30fc\u30bf\u306e\u78ba\u8a8d<\/p>\n<\/div>\n\n\n\n<p><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5-ngs-\u3068\u306e\u6bd4\u8f03\u3082\u7c21\u5358\u306b\">\u6b21\u4e16\u4ee3\u30b7\u30fc\u30b1\u30f3\u30b5(NGS)\u3068\u306e\u6bd4\u8f03\u3082\u7c21\u5358\u306b\uff01<\/h2>\n\n\n\n<p>Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u306f\u3001NGS\u306e\u30c7\u30fc\u30bf\uff08.vcf\u30d5\u30a1\u30a4\u30eb\uff09\u3092\u30a4\u30f3\u30dd\u30fc\u30c8\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u5f97\u3089\u308c\u305f\u5909\u7570\u306b\u30a2\u30ce\u30c6\u30fc\u30b7\u30e7\u30f3\u4ed8\u3051\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30a2\u30e9\u30a4\u30e1\u30f3\u30c8\u753b\u9762\u3068\u30d9\u30f3\u30c0\u30a4\u30a2\u30b0\u30e9\u30e0\u3067\u30c7\u30fc\u30bf\u3092\u53ef\u8996\u5316\u3057\u3001NGS\u30c7\u30fc\u30bf\u306e\u8fc5\u901f\u306a\u691c\u8a3c\u3092\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-content-justification-center is-layout-flex wp-container-core-group-is-layout-4b2eccd6 wp-block-group-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"268\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/f96d9b4281f6d16b3c7589aed5a17be5-1024x268.jpg\" alt=\"\u56f35. NGS\u3068\u306e\u6bd4\u8f03\" class=\"wp-image-24666\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/f96d9b4281f6d16b3c7589aed5a17be5-1024x268.jpg 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/f96d9b4281f6d16b3c7589aed5a17be5-300x78.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/f96d9b4281f6d16b3c7589aed5a17be5-768x201.jpg 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/f96d9b4281f6d16b3c7589aed5a17be5.jpg 1125w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">\u56f35. NGS\u3068\u306e\u6bd4\u8f03<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p>\u4eca\u56de\u306f\u30b3\u30b9\u30c8\u52b9\u7387\u306e\u826f\u3044\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u3067\u30de\u30a4\u30ca\u30fc\u5909\u7570\u306e\u691c\u51fa\u3092\u53ef\u80fd\u306b\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u3054\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p>\u30fb\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u306e\u30c7\u30fc\u30bf\u3092\u7528\u3044\u3066\u30bf\u30fc\u30b2\u30c3\u30c8\u30b5\u30f3\u30d7\u30eb\u306e\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316<br>\u30fb5%\u7a0b\u5ea6\u306e\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa<br>\u30fb\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u306e\u5909\u66f4\u306f\u4e0d\u8981<br>\u30fbNGS\u3068\u306e\u6bd4\u8f03\u3084\u30a2\u30ce\u30c6\u30fc\u30b7\u30e7\u30f3\u3082\u7c21\u5358\u306b\u884c\u3048\u308b<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u30de\u30a4\u30ca\u30fc\u5909\u7570\u306e\u78ba\u8a8d\u3092\u884c\u3044\u305f\u3044\u65b9\u306f-\u7121\u6599\u306eminor-variant-finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u305c\u3072\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u30de\u30a4\u30ca\u30fc\u5909\u7570\u306e\u78ba\u8a8d\u3092\u884c\u3044\u305f\u3044\u65b9\u306f\u3001\u7121\u6599\u306eMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u305c\u3072\u3054\u6d3b\u7528\u304f\u3060\u3055\u3044\u3002<\/h4>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/sequencing\/sanger-sequencing\/sanger-dna-sequencing\/sanger-sequencing-data-analysis\/minor-variant-finder-software.html?CID=gsd_cap_r04_jp_cp0000_pjt0000_gsd00000_0so_blg_sanger_seq_mutational_analysis_gsd_ts_ce_26007_Social_LAB\n\" target=\"_blank\" rel=\"noreferrer noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u3067\u306f\u300125%\u7a0b\u5ea6\u306e\u5272\u5408\u306e\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u3053\u308c\u3088\u308a\u3082\u4f4e\u3044\u5272\u5408\u306e\u5909\u7570\u691c\u51fa\u306f\u6975\u3081\u3066\u56f0\u96e3\u3067\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u816b\u760d\u5b66\u3084\u611f\u67d3\u75c7\u5b66\u306a\u3069\u306e\u7814\u7a76\u5206\u91ce\u306b\u304a\u3044\u3066\u3001\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308b\u3053\u3068\u306f\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059<\/p>\n","protected":false},"author":975,"featured_media":24648,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[183,184],"division":[],"class_list":{"0":"post-24647","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-sanger-seq","9":"tag-mutational-analysis","10":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30675%\u306e\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7d39\u4ecb\u3002\u72ec\u81ea\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3057\u3001NGS\u691c\u8a3c\u3082\u5bb9\u6613\u306b\u3002\u7121\u6599\u30c4\u30fc\u30eb\u3067\u89e3\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\" \/>\n<meta property=\"og:description\" content=\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30675%\u306e\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7d39\u4ecb\u3002\u72ec\u81ea\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3057\u3001NGS\u691c\u8a3c\u3082\u5bb9\u6613\u306b\u3002\u7121\u6599\u30c4\u30fc\u30eb\u3067\u89e3\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2026-02-09T09:08:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-09T09:08:43+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1128\" \/>\n\t<meta property=\"og:image:height\" content=\"512\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"headline\":\"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\",\"datePublished\":\"2026-02-09T09:08:40+00:00\",\"dateModified\":\"2026-02-09T09:08:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/\"},\"wordCount\":50,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/01\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg\",\"keywords\":[\"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9\",\"\u5909\u7570\u89e3\u6790\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/\",\"name\":\"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/01\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg\",\"datePublished\":\"2026-02-09T09:08:40+00:00\",\"dateModified\":\"2026-02-09T09:08:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\"},\"description\":\"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30675%\u306e\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7d39\u4ecb\u3002\u72ec\u81ea\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3057\u3001NGS\u691c\u8a3c\u3082\u5bb9\u6613\u306b\u3002\u7121\u6599\u30c4\u30fc\u30eb\u3067\u89e3\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/01\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/01\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg\",\"width\":1128,\"height\":512},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/bdbe319a2001f279ddce6ab8eaad1253\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench","description":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30675%\u306e\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7d39\u4ecb\u3002\u72ec\u81ea\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3057\u3001NGS\u691c\u8a3c\u3082\u5bb9\u6613\u306b\u3002\u7121\u6599\u30c4\u30fc\u30eb\u3067\u89e3\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","og_description":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30675%\u306e\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7d39\u4ecb\u3002\u72ec\u81ea\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3057\u3001NGS\u691c\u8a3c\u3082\u5bb9\u6613\u306b\u3002\u7121\u6599\u30c4\u30fc\u30eb\u3067\u89e3\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2026-02-09T09:08:40+00:00","article_modified_time":"2026-02-09T09:08:43+00:00","og_image":[{"width":1128,"height":512,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg","type":"image\/jpeg"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"headline":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2","datePublished":"2026-02-09T09:08:40+00:00","dateModified":"2026-02-09T09:08:43+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/"},"wordCount":50,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg","keywords":["\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","\u5909\u7570\u89e3\u6790"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/","name":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg","datePublished":"2026-02-09T09:08:40+00:00","dateModified":"2026-02-09T09:08:43+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253"},"description":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30b7\u30fc\u30b1\u30f3\u30b5\u30675%\u306e\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\u3059\u308bMinor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2\u3092\u7d39\u4ecb\u3002\u72ec\u81ea\u30a2\u30eb\u30b4\u30ea\u30ba\u30e0\u3067\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u5316\u3057\u3001NGS\u691c\u8a3c\u3082\u5bb9\u6613\u306b\u3002\u7121\u6599\u30c4\u30fc\u30eb\u3067\u89e3\u6790\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg","width":1128,"height":512},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/sanger-seq-mutational-analysis-gsd-ts-ce-26007\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30de\u30a4\u30ca\u30fc\u5909\u7570\u3092\u691c\u51fa\uff01Minor Variant Finder\u30bd\u30d5\u30c8\u30a6\u30a8\u30a2"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/bdbe319a2001f279ddce6ab8eaad1253","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":183,"label":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9"},{"value":184,"label":"\u5909\u7570\u89e3\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch-1024x465.jpg",760,345,true],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":183,"name":"\u30b5\u30f3\u30ac\u30fc\u30b7\u30fc\u30b1\u30f3\u30b9","slug":"sanger-seq","term_group":0,"term_taxonomy_id":183,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]},{"term_id":184,"name":"\u5909\u7570\u89e3\u6790","slug":"mutational-analysis","term_group":0,"term_taxonomy_id":184,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/sanger-seq-mutational-analysis-gsd-ts-ce-26007_eyecatch.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/24647","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=24647"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/24647\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/24648"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=24647"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=24647"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=24647"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=24647"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}