{"id":25426,"date":"2026-07-01T11:43:53","date_gmt":"2026-07-01T02:43:53","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/?p=25426"},"modified":"2026-09-14T16:07:20","modified_gmt":"2026-09-14T07:07:20","slug":"case-introduction-elemental-analysis-cmd-26021","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/","title":{"rendered":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6750\u6599\u3084\u30c7\u30d0\u30a4\u30b9\u306e\u7279\u6027\u3092\u8a55\u4fa1\u3059\u308b\u4e0a\u3067\u3001\u88fd\u54c1\u3092\u69cb\u6210\u3059\u308b\u5143\u7d20\u304c\u300c\u3069\u3053\u306b\u300d\u300c\u3069\u306e\u7a0b\u5ea6\u300d\u300c\u3069\u306e\u3088\u3046\u306b\u300d\u5b58\u5728\u3057\u3066\u3044\u308b\u304b\u3092\u628a\u63e1\u3059\u308b\u3053\u3068\u306f\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\u306f\u3001\u8a66\u6599\u4e2d\u306e\u5143\u7d20\u5206\u5e03\u3092\u53ef\u8996\u5316\u3059\u308b\u624b\u6cd5\u3067\u3042\u308a\u3001\u8a66\u4f5c\u8a55\u4fa1\u3084\u6545\u969c\u89e3\u6790\u306b\u304a\u3044\u3066\u6709\u76ca\u306a\u60c5\u5831\u3092\u5f97\u3089\u308c\u308b\u6280\u8853\u3068\u8a00\u3048\u307e\u3059\u3002<br>\u56fa\u4f53\u8a66\u6599\u4e2d\u306e\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\u306b\u306f\u8907\u6570\u306e\u624b\u6cd5\u304c\u5b58\u5728\u3057\u307e\u3059\u304c\u3001\u305d\u308c\u305e\u308c\u9069\u7528\u53ef\u80fd\u306a\u7a7a\u9593\u30b9\u30b1\u30fc\u30eb\u3084\u6fc3\u5ea6\u30ec\u30f3\u30b8\u304c\u7570\u306a\u308a\u307e\u3059\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u6982\u8981\u3092\u6574\u7406\u3057\u305f\u3046\u3048\u3067\u3001LA-ICP-MS\u306e\u7279\u9577\u3068\u3001\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u3078\u306e\u9069\u7528\u4e8b\u4f8b\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002 <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25bc\u3053\u306e\u3088\u3046\u306a\u65b9\u306b\u304a\u3059\u3059\u3081\u3067\u3059\uff01<br>\u30fb\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u306e\u89e3\u6790\u3092\u62c5\u5f53\u3055\u308c\u3066\u3044\u308b\u65b9<br>\u30fb\u03bcm\uff5emm\u30ec\u30d9\u30eb\u306e\u5e83\u57df\u306e\u5143\u7d20\u5206\u5e03\u3092\u8a55\u4fa1\u3057\u305f\u3044\u65b9<br>\u30fbEDX\u3084EPMA\u5206\u6790\u4ee5\u4e0a\u306e\u9ad8\u611f\u5ea6\u304c\u5fc5\u8981\u306a\u65b9<br>\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\u306e\u5b9a\u91cf\u6027\u306b\u8ab2\u984c\u3092\u611f\u3058\u3066\u3044\u308b\u65b9 |<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u6750\u6599\u8a55\u4fa1\u306b\u7528\u3044\u3089\u308c\u308b\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\">\u6750\u6599\u8a55\u4fa1\u306b\u7528\u3044\u3089\u308c\u308b\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\u306f\u3001\u8a66\u6599\u4e2d\u306e\u5143\u7d20\u5206\u5e03\u3092\u9762\u5185\u65b9\u5411\uff082D\uff09\u304a\u3088\u3073\u6df1\u3055\u65b9\u5411\u306b\u53d6\u5f97\u3059\u308b\u624b\u6cd5\u3067\u3001\u5de5\u696d\u6750\u6599\u3084\u30c7\u30d0\u30a4\u30b9\u306e\u8a66\u4f5c\u8a55\u4fa1\u3001\u6545\u969c\u89e3\u6790\u306a\u3069\u306b\u6d3b\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br>\u5fc5\u8981\u3068\u3055\u308c\u308b\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u30b9\u30b1\u30fc\u30eb\u306f\u3001\u8a66\u6599\u3084\u5206\u6790\u76ee\u7684\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u7a7a\u9593\u30b9\u30b1\u30fc\u30eb\u306f\u30c7\u30d0\u30a4\u30b9\u5168\u4f53\u306e\u5e83\u57df\u304b\u3089\u30ca\u30ce\u30ec\u30d9\u30eb\u306e\u5fae\u5c0f\u9818\u57df\u307e\u3067\u3001\u6fc3\u5ea6\u30b9\u30b1\u30fc\u30eb\u306f\u4e3b\u6210\u5206\u304b\u3089\u5fae\u91cf\u4e0d\u7d14\u7269\u307e\u3067\u5e45\u5e83\u3044\u30ec\u30f3\u30b8\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002<br>\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\u306b\u306f\u8907\u6570\u306e\u624b\u6cd5\u304c\u5b58\u5728\u3057\u3001\u305d\u308c\u305e\u308c\u5f97\u610f\u3068\u3059\u308b\u7a7a\u9593\u9818\u57df\u3084\u6fc3\u5ea6\u30ec\u30f3\u30b8\u304c\u7570\u306a\u308b\u305f\u3081\u3001\u76ee\u7684\u306b\u5fdc\u3058\u305f\u9078\u629e\u304c\u5fc5\u8981\u3067\u3059\u3002<br>\u305d\u306e\u4e2d\u3067\u3001\u30ec\u30fc\u30b6\u30fc\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u8a98\u5c0e\u7d50\u5408\u30d7\u30e9\u30ba\u30de\u8cea\u91cf\u5206\u6790\u6cd5\uff08LA-ICP-MS\uff09\u306f\u3001\u9762\u5185\u03bcm\uff5ecm\u30ec\u30d9\u30eb\u306b\u308f\u305f\u308b\u5e83\u3044\u7a7a\u9593\u30b9\u30b1\u30fc\u30eb\u306b\u9069\u7528\u3067\u304d\u3001\u9ad8\u611f\u5ea6\u304b\u3064\u5b9a\u91cf\u7684\u306a\u5206\u6790\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u70b9\u304b\u3089\u3001\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u306e\u8a55\u4fa1\u3078\u306e\u5fdc\u7528\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002 <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"439\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/df78cfacab99cc41faddca1dc0cc1574-1024x439.png\" alt=\"\u56f3_\u5404\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\u6cd5\u304c\u5f97\u610f\u3068\u3059\u308b\u5206\u6790\u9818\u57df\u304a\u3088\u3073\u6fc3\u5ea6\u30ec\u30f3\u30b8\" class=\"wp-image-25430\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/df78cfacab99cc41faddca1dc0cc1574-1024x439.png 1024w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/df78cfacab99cc41faddca1dc0cc1574-300x129.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/df78cfacab99cc41faddca1dc0cc1574-768x329.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/df78cfacab99cc41faddca1dc0cc1574-1536x658.png 1536w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/df78cfacab99cc41faddca1dc0cc1574-2048x878.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-la-icp-ms\u306e\u7279\u9577\">LA-ICP-MS\u306e\u7279\u9577<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5e83\u57df\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3068\u6df1\u3055\u65b9\u5411\u5206\u6790\u3078\u306e\u5bfe\u5fdc\">\u5e83\u57df\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3068\u6df1\u3055\u65b9\u5411\u5206\u6790\u3078\u306e\u5bfe\u5fdc<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">LA-ICP-MS\u3067\u306f\u3001\u30ec\u30fc\u30b6\u30fc\u7167\u5c04\u306b\u3088\u308a\u8a66\u6599\u8868\u9762\u3092\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3057\u3001\u751f\u6210\u3057\u305f\u30a8\u30a2\u30ed\u30be\u30eb\u3092ICP\u30a4\u30aa\u30f3\u6e90\u3067\u539f\u5b50\u5316\u30fb\u30a4\u30aa\u30f3\u5316\u3057\u3001\u8cea\u91cf\u5206\u6790\u8a08\u3067\u691c\u51fa\u3057\u307e\u3059\u3002<br>\u30ec\u30fc\u30b6\u30fc\u7167\u5c04\u4f4d\u7f6e\u3092\u6c34\u5e73\u65b9\u5411\u306b\u8d70\u67fb\u3059\u308b\u3053\u3068\u30672D\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u3092\u3001\u540c\u4e00\u4f4d\u7f6e\u306b\u7e70\u308a\u8fd4\u3057\u7167\u5c04\u3059\u308b\u3053\u3068\u3067\u6df1\u3055\u65b9\u5411\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u3092\u53d6\u5f97\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u30013D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306b\u3082\u5bfe\u5fdc\u53ef\u80fd\u3067\u3059\u3002<br>\u6e2c\u5b9a\u9818\u57df\u306f\u6700\u5c0f\u30d3\u30fc\u30e0\u5f84\u304b\u3089\u6570cm\u89d2\u307e\u3067\u5bfe\u5fdc\u3057\u3001\u6df1\u3055\u65b9\u5411\u306b\u3064\u3044\u3066\u3082\u6570\u5341nm\u304b\u3089\u6570\u767e\u00b5m\u4ee5\u4e0a\u306e\u7bc4\u56f2\u307e\u3067\u5206\u6790\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001\u9762\u5185\u65b9\u5411\u3068\u6df1\u3055\u65b9\u5411\u306e\u4e21\u65b9\u306b\u5bfe\u5fdc\u3059\u308b\u3053\u3068\u3067\u3001\u30c7\u30d0\u30a4\u30b9\u5168\u4f53\u306e\u69cb\u9020\u3084\u5185\u90e8\u5143\u7d20\u5206\u5e03\u3092\u628a\u63e1\u3067\u304d\u307e\u3059\u3002 <\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-\u5e83\u57df\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3068\u5b9a\u91cf\u8a55\u4fa1\u3092\u652f\u3048\u308b\u30ac\u30eb\u30d0\u30ce\u65b9\u5f0f\">\u5e83\u57df\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3068\u5b9a\u91cf\u8a55\u4fa1\u3092\u652f\u3048\u308b\u30ac\u30eb\u30d0\u30ce\u65b9\u5f0f<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306a\u5e83\u3044\u9818\u57df\u3092\u5206\u6790\u3059\u308b\u5834\u5408\u3001\u30ec\u30fc\u30b6\u30fc\u7167\u5c04\u4f4d\u7f6e\u3092\u7cbe\u5bc6\u304b\u3064\u9023\u7d9a\u7684\u306b\u5236\u5fa1\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u3002<br>LA-ICP-MS\u3067\u306f\u3001\u30ec\u30fc\u30b6\u30fc\u3092\u9762\u5185\u65b9\u5411\u306b\u8d70\u67fb\u3057\u306a\u304c\u3089\u5206\u6790\u3057\u307e\u3059\u304c\u3001\u305d\u306e\u8d70\u67fb\u65b9\u5f0f\u3068\u3057\u3066\u30ac\u30eb\u30d0\u30ce\u65b9\u5f0f\u3092\u7528\u3044\u308b\u3053\u3068\u304c\u6709\u52b9\u3067\u3059\u3002<br>\u30ac\u30eb\u30d0\u30ce\u65b9\u5f0f\u3067\u306f\u3001\u9ad8\u7e70\u308a\u8fd4\u3057\u5468\u6ce2\u6570\u30ec\u30fc\u30b6\u30fc\u3068\u30ac\u30eb\u30d0\u30ce\u30df\u30e9\u30fc\u5149\u5b66\u7cfb\u3092\u7d44\u307f\u5408\u308f\u305b\u305f\u300c\u9ad8\u901f\u591a\u70b9\u30a2\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u300d\u3092\u5b9f\u73fe\u3067\u304d\u3001\u30ec\u30fc\u30b6\u30fc\u5149\u3092\u9ad8\u901f\u53ef\u52d5\u30df\u30e9\u30fc\u3067\u8d70\u67fb\u3057\u306a\u304c\u3089\u3001\u7167\u5c04\u4f4d\u7f6e\u3092\u7cbe\u5bc6\u304b\u3064\u9023\u7d9a\u7684\u306b\u5236\u5fa1\u3057\u307e\u3059\u3002<br>\u3053\u306e\u65b9\u5f0f\u306b\u3088\u308a\u3001\u6570mm\u304b\u3089\u6570cm\u89d2\u307e\u3067\u306e\u6e2c\u5b9a\u9818\u57df\u306b\u5bfe\u5fdc\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5805\u7262\u306aThermo Scientific\u2122 ICP-MS\u3068\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u9ad8\u611f\u5ea6\u304b\u3064\u5b9a\u91cf\u7684\u306a\u8a55\u4fa1\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<br>\u30ac\u30eb\u30d0\u30ce\u65b9\u5f0fLA-ICP-MS\u306f\u3001\u5e83\u57df\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3068\u5b9a\u91cf\u8a55\u4fa1\u3092\u5b9f\u73fe\u3059\u308b\u6280\u8853\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e\u5206\u6790\u4e8b\u4f8b\">\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e\u5206\u6790\u4e8b\u4f8b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5168\u56fa\u4f53\u96fb\u6c60\u3067\u306f\u3001\u56fa\u4f53\u96fb\u89e3\u8cea\u5185\u90e8\u3084\u96fb\u6975\u754c\u9762\u306b\u304a\u3051\u308b\u5143\u7d20\u5206\u5e03\u304c\u3001\u51fa\u529b\u7279\u6027\u3084\u5bff\u547d\u306b\u5f71\u97ff\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u5c40\u6240\u7684\u306a\u89b3\u5bdf\u3060\u3051\u3067\u306a\u304f\u3001\u6df1\u3055\u65b9\u5411\u3092\u542b\u3080\u30c7\u30d0\u30a4\u30b9\u5168\u4f53\u306e\u5e83\u57df\u8a55\u4fa1\u304c\u91cd\u8981\u3068\u306a\u308a\u307e\u3059\u3002<br>\u672c\u4e8b\u4f8b\u3067\u306f\u3001\u5e83\u3055\u6570mm\u3001\u6df1\u3055\u7d04100 \u00b5m\u306e3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002<br>\u305d\u306e\u7d50\u679c\u3001\u96fb\u6975\u6d3b\u7269\u8cea\u3001\u96c6\u96fb\u4f53\u3001\u56fa\u4f53\u96fb\u89e3\u8cea\u304b\u3089\u306a\u308b\u591a\u5c64\u69cb\u9020\u30923\u6b21\u5143\u7684\u306b\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"940\" height=\"942\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/5c77ad1abea67ec12017cf2b37f06c8d.png\" alt=\"\u56f3_\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u4e2d\u306e\u4e3b\u306a\u5143\u7d20\u306e3D\u30a4\u30e1\u30fc\u30b8\" class=\"wp-image-25431\" style=\"width:538px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/5c77ad1abea67ec12017cf2b37f06c8d.png 940w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/5c77ad1abea67ec12017cf2b37f06c8d-300x300.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/5c77ad1abea67ec12017cf2b37f06c8d-150x150.png 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/5c77ad1abea67ec12017cf2b37f06c8d-768x770.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/5c77ad1abea67ec12017cf2b37f06c8d-80x80.png 80w\" sizes=\"auto, (max-width: 940px) 100vw, 940px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3089\u306b\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30de\u30c3\u30c1\u30f3\u30b0\u3068\u7d44\u307f\u5408\u308f\u305b\u305f\u3001\u5b9a\u91cf\u6fc3\u5ea6\u306b\u57fa\u3065\u304f\u30de\u30c3\u30d4\u30f3\u30b0\u3082\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001\u4e0d\u7d14\u7269\u5143\u7d20\u304c\u9ad8\u6fc3\u5ea6\u306b\u5b58\u5728\u3059\u308b\u7b87\u6240\u3092\u660e\u77ad\u306b\u78ba\u8a8d\u3067\u304d\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u4e0d\u7d14\u7269\u304c\u5c40\u5728\u3059\u308b\u7570\u5e38\u7b87\u6240\u3092\u628a\u63e1\u3057\u3084\u3059\u304f\u306a\u308a\u3001\u8a66\u4f5c\u8a55\u4fa1\u3084\u6545\u969c\u89e3\u6790\u3092\u30b7\u30f3\u30d7\u30eb\u304b\u3064\u6b63\u78ba\u306b\u884c\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"779\" height=\"780\" src=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/2999f7473d683f60032b8df8d9c9cab4.png\" alt=\" \u56f3\uff1a\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u4e2d\u306eFe\u306e\u5b9a\u91cf\u6fc3\u5ea6\u30de\u30c3\u30d4\u30f3\u30b0\" class=\"wp-image-25432\" style=\"width:538px\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/2999f7473d683f60032b8df8d9c9cab4.png 779w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/2999f7473d683f60032b8df8d9c9cab4-300x300.png 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/2999f7473d683f60032b8df8d9c9cab4-150x150.png 150w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/2999f7473d683f60032b8df8d9c9cab4-768x769.png 768w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/2999f7473d683f60032b8df8d9c9cab4-80x80.png 80w\" sizes=\"auto, (max-width: 779px) 100vw, 779px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-\u307e\u3068\u3081\">\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30eb\u30d0\u30ce\u65b9\u5f0fLA-ICP-MS\u306f\u3001<br>\u30fb\u5e83\u57df3D\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0<br>\u30fb\u30b5\u30d6ppb\u30ec\u30d9\u30eb\u306e\u9ad8\u611f\u5ea6\u691c\u51fa<br>\u30fb\u5b9a\u91cf\u6fc3\u5ea6\u306b\u57fa\u3065\u304f\u5206\u5e03\u8a55\u4fa1<br>\u306b\u5bfe\u5fdc\u53ef\u80fd\u306a\u5206\u6790\u624b\u6cd5\u3067\u3059\u3002<br>\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e\u4e8b\u4f8b\u306e\u3088\u3046\u306b\u3001\u6750\u6599\u3084\u30c7\u30d0\u30a4\u30b9\u4e2d\u306e\u5e83\u57df\u306e\u5143\u7d20\u5206\u5e03\u3092\u5b9a\u91cf\u7684\u306b\u8a55\u4fa1\u3067\u304d\u307e\u3059\u3002 <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3088\u308a\u8a73\u7d30\u306a\u6280\u8853\u60c5\u5831\u306b\u3064\u3044\u3066\u306f\u3001\u4e0b\u8a18\u8cc7\u6599\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\" id=\"h-la-icp-ms\u306b\u3088\u308b\u5e83\u57df-\u5b9a\u91cf\u7684\u306a\u6df1\u3055\u65b9\u5411\u5206\u6790\u304a\u3088\u3073\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\">LA-ICP-MS\u306b\u3088\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u7684\u306a\u6df1\u3055\u65b9\u5411\u5206\u6790\u304a\u3088\u3073\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790<\/h4>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/about-us\/events\/schedule\/la-icp-ms-oes-registration.html?cid=E.25CMD.JP102.28222.01&amp;ICID=cmd_xxx_r04_jp_cp0000_pjt0000_cmd00000_0so_blg_case_introduction_elemental_analysis_cmd_26021_Social_LAB\n\" target=\"_blank\" rel=\"noreferrer noopener\">\u8a73\u7d30\u3092\u898b\u308b<\/a><\/p>\n\n\n\n<div class=\"wp-block-group is-layout-constrained wp-block-group-is-layout-constrained\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u6750\u6599\u3084\u30c7\u30d0\u30a4\u30b9\u306e\u7279\u6027\u3092\u8a55\u4fa1\u3059\u308b\u4e0a\u3067\u3001\u88fd\u54c1\u3092\u69cb\u6210\u3059\u308b\u5143\u7d20\u304c\u300c\u3069\u3053\u306b\u300d\u300c\u3069\u306e\u7a0b\u5ea6\u300d\u300c\u3069\u306e\u3088\u3046\u306b\u300d\u5b58\u5728\u3057\u3066\u3044\u308b\u304b\u3092\u628a\u63e1\u3059\u308b\u3053\u3068\u306f\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u5206\u6790\u306f\u3001\u8a66\u6599\u4e2d\u306e\u5143\u7d20\u5206\u5e03\u3092\u53ef\u8996\u5316\u3059\u308b\u624b\u6cd5\u3067\u3042\u308a\u3001\u8a66\u4f5c\u8a55\u4fa1\u3084\u6545\u969c\u89e3\u6790<\/p>\n","protected":false},"author":975,"featured_media":25428,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[157],"tags":[228,244],"division":[],"class_list":["post-25426","post","type-post","status-publish","format-standard","has-post-thumbnail","category-analysis","tag-228","tag-elemental-analysis","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0 - Learning at the Bench<\/title>\n<meta name=\"description\" content=\"LA-ICP-MS\u3092\u7528\u3044\u305f\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u89e3\u8aac\u8a18\u4e8b\u3067\u3059\u3002EDX\u3084EPMA\u3067\u306f\u611f\u5ea6\u304c\u8db3\u308a\u306a\u3044\u3001\u5b9a\u91cf\u6027\u3084\u6570mm\u301ccm\u30ec\u30d9\u30eb\u306e\u5e83\u57df\u8a55\u4fa1\u306b\u8ab2\u984c\u304c\u3042\u308b\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u89e3\u6790\u62c5\u5f53\u8005\u69d8\u306b\u304a\u3059\u3059\u3081\u3002\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3084\u9244\uff08Fe\uff09\u306e\u5b9a\u91cf\u30de\u30c3\u30d4\u30f3\u30b0\u4e8b\u4f8b\u3082\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\" \/>\n<meta property=\"og:description\" content=\"LA-ICP-MS\u3092\u7528\u3044\u305f\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u89e3\u8aac\u8a18\u4e8b\u3067\u3059\u3002EDX\u3084EPMA\u3067\u306f\u611f\u5ea6\u304c\u8db3\u308a\u306a\u3044\u3001\u5b9a\u91cf\u6027\u3084\u6570mm\u301ccm\u30ec\u30d9\u30eb\u306e\u5e83\u57df\u8a55\u4fa1\u306b\u8ab2\u984c\u304c\u3042\u308b\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u89e3\u6790\u62c5\u5f53\u8005\u69d8\u306b\u304a\u3059\u3059\u3081\u3002\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3084\u9244\uff08Fe\uff09\u306e\u5b9a\u91cf\u30de\u30c3\u30d4\u30f3\u30b0\u4e8b\u4f8b\u3082\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2026-07-01T02:43:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-09-14T07:07:20+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png\" \/>\n\t<meta property=\"og:image:width\" content=\"680\" \/>\n\t<meta property=\"og:image:height\" content=\"681\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LatB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LatB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/\"},\"author\":{\"name\":\"LatB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"headline\":\"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\",\"datePublished\":\"2026-07-01T02:43:53+00:00\",\"dateModified\":\"2026-09-14T07:07:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/\"},\"wordCount\":32,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/06\\\/bdbfcee1bc3be8134db57d427e40ddb9.png\",\"keywords\":[\"\u4e8b\u4f8b\u7d39\u4ecb\",\"\u5143\u7d20\u5206\u6790\"],\"articleSection\":[\"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/\",\"name\":\"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/06\\\/bdbfcee1bc3be8134db57d427e40ddb9.png\",\"datePublished\":\"2026-07-01T02:43:53+00:00\",\"dateModified\":\"2026-09-14T07:07:20+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\"},\"description\":\"LA-ICP-MS\u3092\u7528\u3044\u305f\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u89e3\u8aac\u8a18\u4e8b\u3067\u3059\u3002EDX\u3084EPMA\u3067\u306f\u611f\u5ea6\u304c\u8db3\u308a\u306a\u3044\u3001\u5b9a\u91cf\u6027\u3084\u6570mm\u301ccm\u30ec\u30d9\u30eb\u306e\u5e83\u57df\u8a55\u4fa1\u306b\u8ab2\u984c\u304c\u3042\u308b\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u89e3\u6790\u62c5\u5f53\u8005\u69d8\u306b\u304a\u3059\u3059\u3081\u3002\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3084\u9244\uff08Fe\uff09\u306e\u5b9a\u91cf\u30de\u30c3\u30d4\u30f3\u30b0\u4e8b\u4f8b\u3082\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/06\\\/bdbfcee1bc3be8134db57d427e40ddb9.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2026\\\/06\\\/bdbfcee1bc3be8134db57d427e40ddb9.png\",\"width\":680,\"height\":681},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/case-introduction-elemental-analysis-cmd-26021\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/8fb77bfc3606f049738f28976032baa7\",\"name\":\"LatB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g\",\"caption\":\"LatB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/lgbadmin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0 - Learning at the Bench","description":"LA-ICP-MS\u3092\u7528\u3044\u305f\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u89e3\u8aac\u8a18\u4e8b\u3067\u3059\u3002EDX\u3084EPMA\u3067\u306f\u611f\u5ea6\u304c\u8db3\u308a\u306a\u3044\u3001\u5b9a\u91cf\u6027\u3084\u6570mm\u301ccm\u30ec\u30d9\u30eb\u306e\u5e83\u57df\u8a55\u4fa1\u306b\u8ab2\u984c\u304c\u3042\u308b\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u89e3\u6790\u62c5\u5f53\u8005\u69d8\u306b\u304a\u3059\u3059\u3081\u3002\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3084\u9244\uff08Fe\uff09\u306e\u5b9a\u91cf\u30de\u30c3\u30d4\u30f3\u30b0\u4e8b\u4f8b\u3082\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/","og_locale":"ja_JP","og_type":"article","og_title":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","og_description":"LA-ICP-MS\u3092\u7528\u3044\u305f\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u89e3\u8aac\u8a18\u4e8b\u3067\u3059\u3002EDX\u3084EPMA\u3067\u306f\u611f\u5ea6\u304c\u8db3\u308a\u306a\u3044\u3001\u5b9a\u91cf\u6027\u3084\u6570mm\u301ccm\u30ec\u30d9\u30eb\u306e\u5e83\u57df\u8a55\u4fa1\u306b\u8ab2\u984c\u304c\u3042\u308b\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u89e3\u6790\u62c5\u5f53\u8005\u69d8\u306b\u304a\u3059\u3059\u3081\u3002\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3084\u9244\uff08Fe\uff09\u306e\u5b9a\u91cf\u30de\u30c3\u30d4\u30f3\u30b0\u4e8b\u4f8b\u3082\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2026-07-01T02:43:53+00:00","article_modified_time":"2026-09-14T07:07:20+00:00","og_image":[{"width":680,"height":681,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png","type":"image\/png"}],"author":"LatB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LatB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/"},"author":{"name":"LatB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"headline":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","datePublished":"2026-07-01T02:43:53+00:00","dateModified":"2026-09-14T07:07:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/"},"wordCount":32,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png","keywords":["\u4e8b\u4f8b\u7d39\u4ecb","\u5143\u7d20\u5206\u6790"],"articleSection":["\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/","name":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png","datePublished":"2026-07-01T02:43:53+00:00","dateModified":"2026-09-14T07:07:20+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7"},"description":"LA-ICP-MS\u3092\u7528\u3044\u305f\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u306e\u89e3\u8aac\u8a18\u4e8b\u3067\u3059\u3002EDX\u3084EPMA\u3067\u306f\u611f\u5ea6\u304c\u8db3\u308a\u306a\u3044\u3001\u5b9a\u91cf\u6027\u3084\u6570mm\u301ccm\u30ec\u30d9\u30eb\u306e\u5e83\u57df\u8a55\u4fa1\u306b\u8ab2\u984c\u304c\u3042\u308b\u6750\u6599\u30fb\u30c7\u30d0\u30a4\u30b9\u89e3\u6790\u62c5\u5f53\u8005\u69d8\u306b\u304a\u3059\u3059\u3081\u3002\u5168\u56fa\u4f53\u96fb\u6c60\u30bb\u30eb\u306e3D\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u3084\u9244\uff08Fe\uff09\u306e\u5b9a\u91cf\u30de\u30c3\u30d4\u30f3\u30b0\u4e8b\u4f8b\u3082\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png","width":680,"height":681},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/case-introduction-elemental-analysis-cmd-26021\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"LA-ICP-MS\u3067\u5b9f\u73fe\u3059\u308b\u5e83\u57df\u30fb\u5b9a\u91cf\u5143\u7d20\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/8fb77bfc3606f049738f28976032baa7","name":"LatB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/2b3fdaccc53ad9dae08baccbcf9e8774350bd5682b89e353a9b7a999834e9306?s=96&d=mm&r=g","caption":"LatB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"}]}},"taxonomy_info":{"category":[{"value":157,"label":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023"}],"post_tag":[{"value":228,"label":"\u4e8b\u4f8b\u7d39\u4ecb"},{"value":244,"label":"\u5143\u7d20\u5206\u6790"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png",680,681,false],"author_info":{"display_name":"LatB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/lgbadmin\/"},"comment_info":0,"category_info":[{"term_id":157,"name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","slug":"analysis","term_group":0,"term_taxonomy_id":157,"taxonomy":"category","description":"","parent":0,"count":107,"filter":"raw","meta":[],"cat_ID":157,"category_count":107,"category_description":"","cat_name":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","category_nicename":"analysis","category_parent":0}],"tag_info":[{"term_id":228,"name":"\u4e8b\u4f8b\u7d39\u4ecb","slug":"%e4%ba%8b%e4%be%8b%e7%b4%b9%e4%bb%8b","term_group":0,"term_taxonomy_id":228,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":244,"name":"\u5143\u7d20\u5206\u6790","slug":"elemental-analysis","term_group":0,"term_taxonomy_id":244,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"amp_enabled":false,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/06\/bdbfcee1bc3be8134db57d427e40ddb9.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/25426","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/975"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=25426"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/25426\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/25428"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=25426"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=25426"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=25426"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=25426"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}