{"id":265,"date":"2016-01-31T00:00:00","date_gmt":"2016-01-31T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/"},"modified":"2025-02-10T11:56:41","modified_gmt":"2025-02-10T02:56:41","slug":"cell-image-analyzing1","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/","title":{"rendered":"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081"},"content":{"rendered":"<p>\u8fd1\u5e74\u3001\u7d30\u80de\u751f\u7269\u5b66\u5206\u91ce\u306e\u3055\u307e\u3056\u307e\u306a\u7814\u7a76\u306f\u3001\u6570\u3005\u306e\u75c5\u614b\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u6cbb\u7642\u6cd5\u306e\u691c\u7d22\u306b\u91cd\u8981\u306a\u6280\u8853\u3068\u3057\u3066\u3055\u3089\u306a\u308b\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u5f0a\u793e\u306e\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306f\u3001\u7d30\u80de\u64ae\u5f71\u753b\u50cf\u304b\u3089\u5404\u7a2e\u60c5\u5831\u3092\u6570\u5024\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9a\u91cf\u7684\u3067\u5ba2\u89b3\u7684\u306a\u7d30\u80de\u89e3\u6790\uff08HCA\/HCS\uff09\u3092\u53ef\u80fd\u3068\u3059\u308b\u6e2c\u5b9a\u6a5f\u5668\u3067\u3059\u3002\u4eca\u56de\u3068\u6b21\u56de\u306e2\u56de\u306b\u308f\u305f\u308a\u3001\u3053\u306e\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306b\u7126\u70b9\u3092\u5f53\u3066\u3066\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u6982\u8981\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u3001\u6b21\u56de\u306f\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<h2>\u7d30\u80de\u89e3\u6790\u6280\u8853\u307e\u3068\u3081<\/h2>\n<p>\u8fd1\u5e74\u306e\u6280\u8853\u306e\u9032\u6b69\u306b\u4f34\u3044\u3001\u7d30\u80de\u5206\u6790\u306e\u6280\u8853\u306f\u591a\u304f\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u305d\u308c\u306b\u3088\u3063\u3066\u3001\u4eca\u307e\u3067\u306e\u5206\u6790\u7d50\u679c\u306b\u52a0\u3048\u305f\u65b0\u3057\u3044\u30cb\u30fc\u30ba\u3082\u751f\u307e\u308c\u3066\u304d\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u305f\u3068\u3048\u3070<strong>\u86cd\u5149\u9855\u5fae\u93e1<\/strong>\u306f\u7d30\u80de\u89b3\u5bdf\u306b\u53e4\u304f\u304b\u3089\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001<strong>\u7d30\u80de\u5f62\u614b\u60c5\u5831\u3084\u86cd\u5149\u5f37\u5ea6\u6bd4\u8f03\u306a\u3069\u306f\u89b3\u5bdf\u8005\u306e\u4e3b\u89b3\u306b\u5de6\u53f3\u3055\u308c\u3066\u3057\u307e\u3044\u3001\u307e\u305f\u7d71\u8a08\u5b66\u7684\u306a\u51e6\u7406\u3092\u884c\u3046\u307b\u3069\u306e\u5927\u91cf\u306e\u7d30\u80de\u6570\u306e\u89b3\u5bdf\u306f\u96e3\u3057\u3044<\/strong>\u3053\u3068\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n<p>\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306b\u7d30\u80de\u304b\u3089\u306e\u86cd\u5149\u3092\u5b9a\u91cf\u3059\u308b\u306e\u3067\u3042\u308c\u3070\u3001<strong>\u86cd\u5149\u30d7\u30ec\u30fc\u30c8\u30ea\u30fc\u30c0\u30fc<\/strong>\u306e\u3088\u3046\u306a\u86cd\u5149\u8aad\u307f\u53d6\u308a\u88c5\u7f6e\u3092\u7528\u3044\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u304c\u3001<strong>\u57f9\u990a\u30d7\u30ec\u30fc\u30c8\u306e\uff11\u3064\uff11\u3064\u306e\u30a6\u30a7\u30eb\u306b\u3042\u308b\u7d30\u80de\u306e\u5f62\u614b\u3001\u7d30\u80de\u6570\u3001\u3042\u308b\u86cd\u5149\u5f37\u5ea6\u3092\u3082\u3064\u7d30\u80de\u304c\u3069\u306e\u304f\u3089\u3044\u5b58\u5728\u3059\u308b\u306e\u304b\u3001\u30b5\u30d6\u30dd\u30d4\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u89e3\u6790\u306a\u3069\u306e\u30cb\u30fc\u30ba\u306b\u306f\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u96e3\u3057\u3044<\/strong>\u3067\u3059\u3002<\/p>\n<p>\u7d30\u80de\u4e00\u3064\u4e00\u3064\u306e\u6301\u3064\u86cd\u5149\u5f37\u5ea6\u3092\u9ad8\u611f\u5ea6\u3067\u6e2c\u5b9a\u3059\u308b\u6a5f\u5668\u3068\u3057\u3066\u767b\u5834\u3057\u305f\u306e\u304c\u3001<strong>\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30fc\u30bf\u30fc<\/strong>\u3067\u3042\u308a\u307e\u3059\u304c\u3001<strong>\u7d30\u80de\u3092\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306b\u6eb6\u6db2\u4e2d\u306b\u6d6e\u904a\u3057\u3066\u3044\u308b\u72b6\u614b\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u3001\u307e\u305f\u7d30\u80de\u3092\u6bd4\u8f03\u7684\u5927\u91cf\u306b\u8abf\u6574\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u7d30\u80de\u5f62\u614b\u3084\u7d30\u80de\u5185\u306e\u5206\u5b50\u306e\u5c40\u5728\u3092\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u306b\u306f\u5411\u3044\u3066\u3044\u306a\u3044<\/strong>\u3053\u3068\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n<p class=\"al-c\">\u8868 \u7d30\u80de\u5206\u6790\u306b\u7528\u3044\u3089\u308c\u308b\u4ee3\u8868\u7684\u6a5f\u5668<\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u8a08\u6e2c\u53ef\u80fd\u306a\u9805\u76ee<\/td>\n<td>\u4eca\u307e\u3067\u306e\u5206\u6790\u7d50\u679c\u306b\u52a0\u3048\u305f\u65b0\u3057\u3044\u30cb\u30fc\u30ba<\/td>\n<\/tr>\n<tr>\n<td>\u9855\u5fae\u93e1\u30fb\u86cd\u5149\u9855\u5fae\u93e1<\/td>\n<td>\u30fb\u753b\u50cf\u30c7\u30fc\u30bf<br \/>\n\u30fb\u7d30\u80de\u5f62\u614b<br \/>\n\u30fb\u7d30\u80de\u5185\u5c40\u5728<br \/>\n\u30fb\u8a08\u6e2c\u5bfe\u8c61\uff1a\u7d30\u80de\u30fb\u7d44\u7e54\u306a\u3069<\/td>\n<td>\u30fb\u753b\u50cf\u30c7\u30fc\u30bf\u306e\u5b9a\u91cf\u6027<br \/>\n\uff08\u6570\u5024\u5316\uff1a\u7d71\u8a08\u89e3\u6790\uff09<br \/>\n\u30fb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8<\/td>\n<\/tr>\n<tr>\n<td>\u30d7\u30ec\u30fc\u30c8\u30ea\u30fc\u30c0\u30fc<\/td>\n<td>\u30fb\u30a6\u30a7\u30eb\u5185\u86cd\u5149\u30fb\u767a\u5149\u6570\u5024\u5316\u30c7\u30fc\u30bf<br \/>\n\u30fb\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u8a08\u6e2c<\/td>\n<td>\u30fb\u30b7\u30f3\u30b0\u30eb\u30bb\u30eb\u306e\u60c5\u5831<br \/>\n\u30fb\u7d30\u80de\u5f62\u614b<br \/>\n\u30fb\u7d30\u80de\u5185\u5c40\u5728<\/td>\n<\/tr>\n<tr>\n<td>\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30fc\u30bf\u30fc<\/td>\n<td>\u30fb\u86cd\u5149\u67d3\u8272\u3055\u308c\u305f\u30b7\u30f3\u30b0\u30eb\u30bb\u30eb\u306e\u60c5\u5831<br \/>\n\u30fb\u7d30\u80de\u96c6\u56e3\u30af\u30e9\u30b9\u30bf\u30fc\u89e3\u6790<\/td>\n<td>\u30fb\u7d30\u80de\u5185\u5c40\u5728<br \/>\n\u30fb\u5e45\u5e83\u3044\u8a08\u6e2c\u5bfe\u8c61\uff08\u63a5\u7740\u7d30\u80de\u30fb\u7d44\u7e54\uff09<br \/>\n\u30fb\u524d\u51e6\u7406\u306e\u7c21\u4fbf\u5316<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>High Content Analysis\u3068\u306f\uff1f<\/h2>\n<p>1990\u5e74\u4ee3\u306e\u5f8c\u534a\u306b\u78ba\u7acb\u3055\u308c\u305f\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u89e3\u6790\u306f\u3082\u3063\u3068\u3082\u9032\u5316\u3057\u305f\u7d30\u80de\u5206\u6790\u6280\u8853\u306e\u4e00\u3064\u3067\u3059\u3002\u57f9\u990a\u30d7\u30ec\u30fc\u30c8\u3084\u30b9\u30e9\u30a4\u30c9\u30b0\u30e9\u30b9\u304b\u3089\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\uff08\u753b\u50cf\uff09\u3092\u53d6\u5f97\u3057\u3001\u30b3\u30f3\u30d4\u30e5\u30fc\u30bf\u30fc\u89e3\u6790\u3059\u308b\u3053\u3068\u304b\u3089\u3001\u5ba2\u89b3\u7684\u304b\u3064\u5927\u91cf\u306e\u7d30\u80de\u60c5\u5831\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u4e00\u3064\u4e00\u3064\u306e\u7d30\u80de\u304b\u3089\u5f62\u614b\u3084\u86cd\u5149\u60c5\u5831\u306e\u5c40\u5728\u306b\u3044\u305f\u308b\u307e\u3067\u30c9\u30ea\u30eb\u30c0\u30a6\u30f3\u3057\u3066\u3044\u304f\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3057\u305f\u3002<strong>\u3053\u306e\u6280\u8853\u306f\u5f93\u6765\u306e\u65b9\u6cd5\u3068\u6bd4\u3079\u3066\u3001\u591a\u304f\u306e\u6709\u7528\u304b\u3064\u8a73\u7d30\uff08High Content\uff09\u306a\u60c5\u5831\u3092\u7814\u7a76\u8005\u306b\u63d0\u4f9b\u3059\u308b\u3053\u3068\u304b\u3089\u3001High Content Analysis (HCA) \u3068\u547d\u540d\u3055\u308c\u305f\u6700\u65b0\u306e\u7d30\u80de\u5206\u6790\u624b\u6cd5<\/strong>\u3067\u3059\u3002<\/p>\n<p>\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306f\u3001\u86cd\u5149\u30e9\u30d9\u30eb\u3057\u305f\u7d30\u80de\u753b\u50cf\u3092\u5168\u81ea\u52d5\u3067\u53d6\u308a\u8fbc\u3093\u3067\u89e3\u6790\u3059\u308b\u6a5f\u5668\u3067\u3001\u4e0a\u8a18\u306b\u6319\u3052\u305f\u86cd\u5149\u9855\u5fae\u93e1\u3001\u30d7\u30ec\u30fc\u30c8\u30ea\u30fc\u30c0\u30fc\u304a\u3088\u3073\u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30fc\u30bf\u30fc\u3068\u3044\u3063\u305f\u4eca\u307e\u3067\u306e\u5206\u6790\u624b\u6cd5\u304b\u3089\u4e00\u6b69\u9032\u3093\u3060HCA\u3092\u5b9f\u73fe\u3059\u308b\u6a5f\u5668\u3067\u3059\u3002\u3053\u306e\u6a5f\u5668\u30fb\u6280\u8853\u306b\u3088\u3063\u3066\u3001<strong>\u5927\u91cf\u306e\u57f9\u990a\u30d7\u30ec\u30fc\u30c8\u3084\u30b9\u30e9\u30a4\u30c9\u4e0a\u306e\u7d30\u80de\u306e\u86cd\u5149\u5f37\u5ea6\u3092\u306f\u3058\u3081\u3001\u86cd\u5149\u5206\u5e03\u3084\u5171\u5c40\u5728\u306e\u60c5\u5831\u3001\u7d30\u80de\u5f62\u614b\u3092\u6570\u5024\u5316\u3059\u308b\u3053\u3068\u304c\u7c21\u5358\u306b\u3067\u304d\u308b<\/strong>\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n<div id=\"attachment_792\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing1-fig.jpg\" rel=\"attachment wp-att-792\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-792\" class=\"size-full wp-image-792\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing1-fig.jpg\" alt=\"cell-image-analyzing1-fig\" width=\"500\" height=\"365\" \/><\/a><p id=\"caption-attachment-792\" class=\"wp-caption-text\">\u56f3 \u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306b\u3088\u3063\u3066\u53d6\u5f97\u3057\u305f\u7d30\u80de\u753b\u50cf\u3092\u89e3\u6790\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b\u3088\u3063\u3066\u89e3\u6790\u3057\u305f\u4f8b\u3002\u86cd\u5149\u9855\u5fae\u93e1\u306e\u753b\u50cf\u306b\u3042\u308b\u6838\u3001\u7d30\u80de\u8cea\u90e8\u5206\u3092\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u8a8d\u8b58\u3057\uff08\u56f3\u4e2d\u6bb5\uff09\u3001\u7d30\u80de\u3072\u3068\u3064\u3072\u3068\u3064\u304b\u3089\u5f97\u305f\u86cd\u5149\u5f37\u5ea6\u3092\u6570\u5024\u5b9a\u91cf\u5316\u3057\u307e\u3059\uff08\u56f3\u4e0b\u6bb5\uff09\u3002\u3053\u306e\u3088\u3046\u306b\u5b9a\u91cf\u5316\u3055\u308c\u305f\u60c5\u5831\u3092\u30d7\u30ed\u30c3\u30c8\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u30c7\u30fc\u30bf\u30b0\u30e9\u30d5\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\uff08\u56f3\u4e0a\u6bb5\uff09\u3002<\/p><\/div>\n<p>\u3053\u306eHCA\u306f\u3001<strong>\u5275\u85ac\u306b\u304a\u3051\u308b\u85ac\u52b9\u5224\u5b9a\u3084\u5b89\u5168\u6027\u8a66\u9a13\u7b49\u306e\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u89e3\u6790\u7b49\u306e\u81a8\u5927\u306a\u91cf\u306e\u30c7\u30fc\u30bf\u89e3\u6790\u306b\u5229\u7528\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd<\/strong>\u3067\u3059\u3002HCA\u3092\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306b\u5fdc\u7528\u3059\u308b\u624b\u6cd5\u306fHigh Content Screening(HCS)\u3068\u547d\u540d\u3055\u308c\u3066\u3044\u307e\u3059\u300290\u5e74\u4ee3\u5f8c\u534a\u306b\u306f\u3001\u7c73\u56fdCellomics\u793e\uff08\u73fe \u30b5\u30fc\u30e2\u30d5\u30a3\u30c3\u30b7\u30e3\u30fc\u30b5\u30a4\u30a8\u30f3\u30c6\u30a3\u30d5\u30a3\u30c3\u30af\u793e\uff09\u304c\u4e16\u754c\u3067\u6700\u521d\u306b\u958b\u767a\u3057\u305f\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306b\u3088\u3063\u3066\u3001HCS\u306b\u304a\u3051\u308b\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u304a\u3088\u3073\u7cbe\u5ea6\u304c\u98db\u8e8d\u7684\u306b\u5411\u4e0a\u3057\u307e\u3057\u305f\u3002<\/p>\n<p>\u6b21\u56de\u306f\u3001\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h1>\u7d30\u80de\u89e3\u6790\u30fb\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\u306b\u3064\u3044\u3066<\/h1>\n<p>\u7d30\u80de\u89e3\u6790\u6a5f\u5668\u306b\u3064\u3044\u3066<\/p>\n<ul style=\"list-style-type: disc\">\n<li><strong>\u30c7\u30e2<\/strong>\u3092\u4f9d\u983c\u3057\u305f\u3044<\/li>\n<li><strong>\u898b\u7a4d\u3082\u308a<\/strong>\u304c\u307b\u3057\u3044<\/li>\n<li>\u305d\u306e\u4ed6\uff08<strong>\u8cc7\u6599\u304c\u307b\u3057\u3044\u3001\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044\u3001\u62c5\u5f53\u8005\u304b\u3089\u9023\u7d61\u304c\u307b\u3057\u3044<\/strong> \u7b49\uff09<\/li>\n<\/ul>\n<p>\u7b49\u306e\u3054\u8981\u671b\u304c\u3042\u308a\u307e\u3057\u305f\u3089\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u6c17\u8efd\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red ext-link wpel-icon-right\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/cell-analysis-demo.html?CID=bid_pca_cx7_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_hcs1_Social_LAB\" target=\"_blank\" rel=\"external noopener noreferrer\" data-wpel-link=\"external\">\u7d30\u80de\u89e3\u6790\u306b\u95a2\u3059\u308b\u304a\u554f\u3044\u5408\u308f\u305b\u306f\u3053\u3061\u3089<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u8fd1\u5e74\u3001\u7d30\u80de\u751f\u7269\u5b66\u5206\u91ce\u306e\u3055\u307e\u3056\u307e\u306a\u7814\u7a76\u306f\u3001\u6570\u3005\u306e\u75c5\u614b\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u6cbb\u7642\u6cd5\u306e\u691c\u7d22\u306b\u91cd\u8981\u306a\u6280\u8853\u3068\u3057\u3066\u3055\u3089\u306a\u308b\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u5f0a\u793e\u306e\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306f\u3001\u7d30\u80de\u64ae\u5f71\u753b\u50cf\u304b\u3089\u5404\u7a2e\u60c5\u5831\u3092\u6570\u5024\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9a\u91cf\u7684\u3067\u5ba2\u89b3\u7684\u306a\u7d30\u80de\u89e3\u6790\uff08HCA\/HCS\uff09\u3092\u53ef\u80fd\u3068\u3059\u308b\u6e2c\u5b9a\u6a5f\u5668\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u6982\u8981\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2412,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[159],"tags":[42],"division":[],"class_list":["post-265","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cell","tag-cell-imaging","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081\" \/>\n<meta property=\"og:description\" content=\"\u8fd1\u5e74\u3001\u7d30\u80de\u751f\u7269\u5b66\u5206\u91ce\u306e\u3055\u307e\u3056\u307e\u306a\u7814\u7a76\u306f\u3001\u6570\u3005\u306e\u75c5\u614b\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u6cbb\u7642\u6cd5\u306e\u691c\u7d22\u306b\u91cd\u8981\u306a\u6280\u8853\u3068\u3057\u3066\u3055\u3089\u306a\u308b\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u5f0a\u793e\u306e\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306f\u3001\u7d30\u80de\u64ae\u5f71\u753b\u50cf\u304b\u3089\u5404\u7a2e\u60c5\u5831\u3092\u6570\u5024\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9a\u91cf\u7684\u3067\u5ba2\u89b3\u7684\u306a\u7d30\u80de\u89e3\u6790\uff08HCA\/HCS\uff09\u3092\u53ef\u80fd\u3068\u3059\u308b\u6e2c\u5b9a\u6a5f\u5668\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u6982\u8981\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-01-31T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-02-10T02:56:41+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081\",\"datePublished\":\"2016-01-31T00:00:00+00:00\",\"dateModified\":\"2025-02-10T02:56:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/\"},\"wordCount\":29,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-image-analyzing-title.jpg\",\"keywords\":[\"\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"articleSection\":[\"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/\",\"name\":\"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-image-analyzing-title.jpg\",\"datePublished\":\"2016-01-31T00:00:00+00:00\",\"dateModified\":\"2025-02-10T02:56:41+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-image-analyzing-title.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/cell-image-analyzing-title.jpg\",\"width\":1200,\"height\":630,\"caption\":\"cell-image-analyzing-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/cell-image-analyzing1\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/","og_locale":"ja_JP","og_type":"article","og_title":"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081","og_description":"\u8fd1\u5e74\u3001\u7d30\u80de\u751f\u7269\u5b66\u5206\u91ce\u306e\u3055\u307e\u3056\u307e\u306a\u7814\u7a76\u306f\u3001\u6570\u3005\u306e\u75c5\u614b\u306b\u5bfe\u3059\u308b\u65b0\u3057\u3044\u6cbb\u7642\u6cd5\u306e\u691c\u7d22\u306b\u91cd\u8981\u306a\u6280\u8853\u3068\u3057\u3066\u3055\u3089\u306a\u308b\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u5f0a\u793e\u306e\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306f\u3001\u7d30\u80de\u64ae\u5f71\u753b\u50cf\u304b\u3089\u5404\u7a2e\u60c5\u5831\u3092\u6570\u5024\u5316\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u5b9a\u91cf\u7684\u3067\u5ba2\u89b3\u7684\u306a\u7d30\u80de\u89e3\u6790\uff08HCA\/HCS\uff09\u3092\u53ef\u80fd\u3068\u3059\u308b\u6e2c\u5b9a\u6a5f\u5668\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u6982\u8981\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-01-31T00:00:00+00:00","article_modified_time":"2025-02-10T02:56:41+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081","datePublished":"2016-01-31T00:00:00+00:00","dateModified":"2025-02-10T02:56:41+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/"},"wordCount":29,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title.jpg","keywords":["\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"articleSection":["\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/","name":"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title.jpg","datePublished":"2016-01-31T00:00:00+00:00","dateModified":"2025-02-10T02:56:41+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title.jpg","width":1200,"height":630,"caption":"cell-image-analyzing-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-image-analyzing1\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u308f\u304b\u308a\u3084\u3059\u3044\uff01\u7d30\u80de\u89e3\u6790\u6280\u8853\u3068\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30a2\u30ca\u30e9\u30a4\u30b6\u30fc\u306e\u307e\u3068\u3081"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":159,"label":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}],"post_tag":[{"value":42,"label":"\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":159,"name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell","term_group":0,"term_taxonomy_id":159,"taxonomy":"category","description":"","parent":0,"count":104,"filter":"raw","meta":[],"cat_ID":159,"category_count":104,"category_description":"","cat_name":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","category_nicename":"cell","category_parent":0}],"tag_info":[{"term_id":42,"name":"\u7d30\u80de\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","slug":"cell-imaging","term_group":0,"term_taxonomy_id":42,"taxonomy":"post_tag","description":"","parent":0,"count":13,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24382,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075\/","url_meta":{"origin":265,"position":0},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066 (Hoechst\u3092\u7528\u3044\u305f\u6838\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670810\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u7d30\u80de\u306b\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-imaging-fluorescent-dye-bid-ts-mbr-25075_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24416,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076\/","url_meta":{"origin":265,"position":1},"title":"Cell Painting Assay\u3067\u7528\u3044\u3089\u308c\u308b\u8a66\u85ac\u306b\u3064\u3044\u3066\uff08MitoTracker\u3092\u7528\u3044\u305f\u30df\u30c8\u30b3\u30f3\u30c9\u30ea\u30a2\u67d3\u8272\uff09","author":"LatB Staff","date":"2025\u5e7412\u670819\u65e5","format":false,"excerpt":"\u8fd1\u5e74\u3001\u30bb\u30eb\u30da\u30a4\u30f3\u30c6\u30a3\u30f3\u30b0\uff08Cell Painting\uff09\u3068\u3044\u3046\u30a2\u30c3\u30bb\u30a4\u65b9\u6cd5\u304c\u5e83\u307e\u308a\u3064\u3064\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/12\/cell-imaging-fluorescent-dye-bid-ts-mbr-25076_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25608,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-basic-cell-culture-bpg-26026\/","url_meta":{"origin":265,"position":2},"title":"\u3010\u7b2c3\u56de\u3011Gibco\u57f9\u5730 60\u5e74\u306e\u30a4\u30ce\u30d9\u30fc\u30b7\u30e7\u30f3\u3002\u7d30\u80de\u57f9\u990a\u306e\u6b74\u53f2\u306f\u57f9\u5730\u306e\u6b74\u53f2\u3002","author":"LatB Staff","date":"2026\u5e7410\u67087\u65e5","format":false,"excerpt":"\u3053\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001\u30d0\u30a4\u30aa\u30d7\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\u30c1\u30fc\u30e0\u304c\u533b\u85ac\u54c1\u88fd\u9020\u306b\u95a2\u9023\u3059\u308b\u3055\u307e\u3056\u307e\u306a\u30c8\u30d4\u30c3\u30af\u3092\u30b7\u30ea\u30fc\u30ba\u3067\u3054\u7d39\u4ecb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cell-culture-basic-cell-culture-bpg-26026_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20124,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25015\/","url_meta":{"origin":265,"position":3},"title":"\u3010\u7b2c1\u56de\u3011Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u3068\u306f\uff1f","author":"LatB Staff","date":"2026\u5e744\u670815\u65e5","format":false,"excerpt":"Exosome\uff08\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff0f\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306e\u7814\u7a76\u304c\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u8208\u5473\u306f\u3042\u3063\u3066\u3082\u3001\u3069\u306e\u3088\u3046\u306b\u7814\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/6fae859c8c1eacdaa39f3ae843ae1bda-scaled.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":265,"position":4},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25472,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-ts-r-25067\/","url_meta":{"origin":265,"position":5},"title":"\u3010\u7b2c7\u56de\u3011 \u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u306e\u6982\u8981","author":"LatB Staff","date":"2026\u5e748\u670813\u65e5","format":false,"excerpt":"\u7d30\u80de\u304c\u5206\u6ccc\u3059\u308b\u7d30\u80de\u5916\u5c0f\u80de\u306e\u4e2d\u3067\u3082\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306f\u305d\u306e\u60c5\u5831\u4f1d\u9054\u6a5f\u80fd\u3084\u75be\u60a3\u3068\u306e\u95a2\u9023\u6027\u304b\u3089\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/cell-image-analyzing-title.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/265","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=265"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/265\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2412"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=265"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=265"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=265"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=265"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}