{"id":272,"date":"2016-02-04T00:00:00","date_gmt":"2016-02-04T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/"},"modified":"2025-07-02T17:09:08","modified_gmt":"2025-07-02T08:09:08","slug":"pipetting-guide4","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/","title":{"rendered":"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081"},"content":{"rendered":"<p>\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u306f\u3001\u7cbe\u5bc6\u5ea6\u3068\u6b63\u78ba\u5ea6\u306e\u4e21\u65b9\u3066\u3099\u8aa4\u5dee\u306e\u306a\u3044\u3053\u3068\u304b\u3099\u91cd\u8981\u3066\u3099\u3059\u3002\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30b9\u30d8\u309a\u30c3\u30af\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u30d5\u30a1\u30af\u30bf\u304b\u3099\u5f71\u97ff\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u3092\u8a55\u4fa1\u3059\u308b\u4e0a\u3066\u3099\u4e3b\u8981\u306a\u5b9a\u91cf\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3066\u3099\u3059\u3002<\/p>\n<p>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306f\u3001\u6db2\u4f53\u3092\u8a08\u91cf\u3057\u5206\u6ce8\u3059\u308b\u305f\u3081\u306e\u4f53\u7a4d\u8a08\u3066\u3099\u3059\u3002\u5b9f\u9a13\u3084\u8a66\u9a13\u691c\u67fb\u3092\u884c\u3046\u4e0a\u3066\u3099\u3001\u8aa4\u5dee\u306e\u5c11\u306a\u3044\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u304b\u3099\u5fc5\u8981\u3068\u3055\u308c\u307e\u3059\u3002\u3057\u305f\u304b\u3099\u3063\u3066\u3001<strong>\u8aa4\u5dee\u306e\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3066\u3099\u3042\u308b\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u304b\u3099\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u8a55\u4fa1\u306e\u57fa\u672c<\/strong>\u3068\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001<strong>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u4ee5\u5916\u306b\u3001\u6e29\u5ea6\u3084\u6e7f\u5ea6\u306a\u3068\u3099\u3055\u307e\u3055\u3099\u307e\u306a\u30d5\u30a1\u30af\u30bf\u304b\u3099\u8aa4\u5dee\u306b\u5f71\u97ff\u3092\u53ca\u307b\u3099\u3057\u307e\u3059<\/strong>\u306e\u3066\u3099\u3001\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3046\u5834\u5408\u306b\u306f\u3001\u305d\u308c\u3089\u306e\u30d5\u30a1\u30af\u30bf\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>\u6b63\u78ba\u5ea6\u3001\u7cbe\u5bc6\u5ea6\u3068\u306f?<\/h2>\n<ul>\n<li><strong>\u6b63\u78ba\u5ea6\uff1a\u8a2d\u5b9a\u3057\u305f\u5bb9\u91cf(\u5206\u6ce8\u3057\u305f\u3044\u5bb9\u91cf)\u3068\u5b9f\u969b\u306e\u5206\u6ce8\u91cf\u3068\u306e\u5dee<\/strong><\/li>\n<li><strong>\u7cbe\u5bc6\u5ea6\uff1a1\u56de\u3053\u3099\u3068\u306e\u5206\u6ce8\u91cf\u306e\u306f\u3099\u3089\u3064\u304d<\/strong><\/li>\n<\/ul>\n<div id=\"attachment_800\" style=\"width: 904px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig1.png\" rel=\"attachment wp-att-800\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-800\" class=\"size-full wp-image-800\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig1.png\" alt=\"pipetting-guide4-fig1\" width=\"894\" height=\"376\" \/><\/a><p id=\"caption-attachment-800\" class=\"wp-caption-text\">\u56f31 \u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306e\u9055\u3044<\/p><\/div>\n<h2>\u6b63\u78ba\u5ea6\u3084\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf<\/h2>\n<h3>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u4f4d\u7f6e\u3068\u89d2\u5ea6 (\u4f8b:1-10ml)<\/h3>\n<div id=\"attachment_801\" style=\"width: 800px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig2.png\" rel=\"attachment wp-att-801\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-801\" class=\"size-full wp-image-801\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig2.png\" alt=\"pipetting-guide4-fig2\" width=\"790\" height=\"388\" \/><\/a><p id=\"caption-attachment-801\" class=\"wp-caption-text\">\u56f32 \u30d4\u30da\u30c3\u30c8\u306e\u4f4d\u7f6e\u3068\u78ba\u5ea6\u306b\u3088\u308b\u6b63\u78ba\u5ea6\u3078\u306e\u5f71\u97ff<\/p><\/div>\n<h3>\u6e29\u5ea6<\/h3>\n<p>\u5206\u6ce8\u3059\u308b\u6db2\u4f53\u306e\u6e29\u5ea6\u306f\u3001<strong>\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u306e\u6b63\u78ba\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u6700\u3082\u91cd\u8981\u306a\u30d5\u30a1\u30af\u30bf<\/strong>\u3066\u3099\u3059\u3002\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3068\u5206\u6ce8\u6db2\u306e\u9593\u306b\u6e29\u5ea6\u5dee\u304b\u3099\u3042\u308b\u5834\u5408\u3001\u975e\u5e38\u306b\u5927\u304d\u306a\u5f71\u97ff\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u56f3\u306b\u300122\u00b0C\u3066\u3099\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3057\u305f\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3066\u3099\u3001\u6e29\u5ea6\u304b\u3099\u7570\u306a\u308b\u6db2\u4f53\u306e\u5206\u6ce8\u3092\u884c\u3063\u305f\u3068\u304d\u306e\u6b63\u78ba\u5ea6\u306e\u5909\u5316\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u30c1\u30c3\u30d5\u309a\u5185\u306e\u6db2\u9762\u3068\u30d2\u309a\u30b9\u30c8\u30f3\u306e\u9593\u306b\u3042\u308b\u4e00\u5b9a\u91cf\u306e\u7a7a\u6c17(\u30a8\u30a2\u30ad\u3099\u30e3\u30c3\u30d5\u309a)\u306e\u4f53\u7a4d\u304b\u3099\u6e29\u5ea6\u5909\u5316\u306b\u4f34\u3063\u3066\u81a8\u5f35\u307e\u305f\u306f\u53ce\u7e2e\u3057\u305f\u305f\u3081\u3066\u3099\u3059\u3002\u307e\u305f\u3001\u5206\u6ce8\u3059\u308b\u6db2\u4f53\u81ea\u4f53\u306e\u4f53\u7a4d\u3082\u6e29\u5ea6\u306b\u3088\u3063\u3066\u5909\u52d5\u3057\u307e\u3059\u3002<\/p>\n<div id=\"attachment_802\" style=\"width: 557px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig3.png\" rel=\"attachment wp-att-802\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-802\" class=\"size-full wp-image-802\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig3.png\" alt=\"pipetting-guide4-fig3\" width=\"547\" height=\"324\" \/><\/a><p id=\"caption-attachment-802\" class=\"wp-caption-text\">\u56f33 \u6db2\u4f53\u306e\u6e29\u5ea6\u306b\u3088\u308b\u6b63\u78ba\u5ea6\u306e\u5909\u5316<\/p><\/div>\n<h3>\u5bc6\u5ea6<\/h3>\n<p>\u5bc6\u5ea6\u3082\u30c1\u30c3\u30d5\u309a\u5185\u306b\u5438\u5f15\u3055\u308c\u308b\u6db2\u4f53\u306e\u5bb9\u91cf\u306b\u5f71\u97ff\u3057\u307e\u3059\u3002\u5bc6\u5ea6\u306f\u3001\u6db2\u4f53\u306e\u91cd\u91cf\/\u5bb9\u91cf\u306e\u6bd4\u3066\u3099\u3001\u4f8b\u3048\u306f\u3099<strong>\u84b8\u7559\u6c34\u306b\u6bd4\u3078\u3099\u3066\u5bc6\u5ea6\u304b\u3099\u9ad8\u3044(\u201c\u91cd\u3044\u201d)\u6db2\u4f53\u304b\u3099\u30c1\u30c3\u30d5\u309a\u306b\u5438\u5f15\u3055\u308c\u308b\u91cf\u306f\u6c34\u3088\u308a\u5c11\u306a\u304f\u3001\u5bc6\u5ea6\u306e\u4f4e\u3044(\u201c\u8efd\u3044\u201d)\u6db2\u4f53\u3066\u3099\u306f\u9006\u306b\u306a\u308a\u307e\u3059<\/strong>\u3002\u3053\u308c\u306f\u3001\u6db2\u9762\u3068\u30d2\u309a\u30b9\u30c8\u30f3\u306e\u9593\u306b\u5b58\u5728\u3059\u308b\u7a7a\u6c17(\u30a8\u30a2\u30ad\u3099\u30e3\u30c3\u30d5\u309a)\u306e\u4f53\u7a4d\u304b\u3099\u5f15\u529b\u306b\u3088\u3063\u3066\u5909\u5316\u3059\u308b\u305f\u3081\u3066\u3099\u3059\u3002\u5bc6\u5ea6\u306f\u3001\u6e29\u5ea6\u3084\u6c17\u5727\u306b\u3088\u3063\u3066\u5909\u5316\u3057\u307e\u3059\u300220\u00b0C\u306b\u304a\u3051\u308b\u4e3b\u306a\u6db2\u4f53\u306e\u5bc6\u5ea6\u306f\u3001\u6c34 0.998 kg\/dm<sup>3<\/sup>\u3001\u30a8\u30bf\u30ce\u30fc\u30eb 0.79 kg\/dm<sup>3<\/sup>\u3001\u786b\u9178(95-98%H<sub>2<\/sub>SO<br \/>\n<sub>4<\/sub>) 1.84 kg\/dm<sup>3<\/sup>\u306a\u3068\u3099\u3066\u3099\u3059\u3002<\/p>\n<div id=\"attachment_803\" style=\"width: 546px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig4.png\" rel=\"attachment wp-att-803\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-803\" class=\"size-full wp-image-803\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig4.png\" alt=\"pipetting-guide4-fig4\" width=\"536\" height=\"321\" \/><\/a><p id=\"caption-attachment-803\" class=\"wp-caption-text\">\u56f34 \u6db2\u4f53\u306e\u5bc6\u5ea6\u306b\u3088\u308b\u6b63\u78ba\u5ea6\u306e\u5909\u5316<\/p><\/div>\n<h3>\u6a19\u9ad8<\/h3>\n<p><strong>\u5730\u7406\u7684\u306a\u6a19\u9ad8\u306b\u3088\u3063\u3066\u6c17\u5727\u304b\u3099\u7570\u306a\u308a\u3001\u6b63\u78ba\u5ea6\u306b\u5f71\u97ff\u3092\u53ca\u307b\u3099\u3057\u307e\u3059<\/strong>\u3002\u6c17\u5727\u306f\u3001\u6a19\u9ad8\u304b\u3099\u9ad8\u3044\u307b\u3068\u3099\u4f4e\u304f\u306a\u308a\u3001\u5909\u63db\u4fc2\u6570Z\u3082\u540c\u69d8\u306b\u5c0f\u3055\u304f\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u6db2\u4f53\u306b\u3088\u3063\u3066\u306f\u6cb8\u70b9\u304b\u3099\u5ba4\u6e29\u8fd1\u304f\u306b\u307e\u3066\u3099\u4e0b\u304b\u3099\u308a\u3001\u84b8\u767a\u306b\u3088\u308b\u6e1b\u5c11\u304b\u3099\u8457\u3057\u304f\u5897\u5927\u3059\u308b\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_804\" style=\"width: 548px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig5.png\" rel=\"attachment wp-att-804\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-804\" class=\"size-full wp-image-804\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide4-fig5.png\" alt=\"pipetting-guide4-fig5\" width=\"538\" height=\"320\" \/><\/a><p id=\"caption-attachment-804\" class=\"wp-caption-text\">\u56f35 \u6a19\u9ad8\u306b\u3088\u308b\u6b63\u78ba\u5ea6\u306e\u5909\u5316<\/p><\/div>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u4e0a\u8a18\u306e\u3088\u3046\u306a\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u3092\u8003\u616e\u3057\u3066\u3001\u6b63\u78ba\u306a\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3044\u307e\u3057\u3087\u3046\uff01<\/p>\n<h3>GLP\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/h3>\n<p>\u5f53\u793e\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c4\u30fc\u30eb\u306e\u9078\u629e\u3084\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u9069\u3057\u305f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c6\u30af\u30cb\u30c3\u30af\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u308b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/glp-guide-form.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc4_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h3>\u3010\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u5c55\u958b\u4e2d\u3011\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u53ef\u80fd\u3067\u3059\uff01<\/h3>\n<p>\u666e\u6bb5\u306e\u5b9f\u9a13\u306b\u6b20\u304b\u305b\u306a\u3044\u30d4\u30da\u30c3\u30c8\u306e\u6821\u6b63\u306b\u3064\u3044\u3066\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u60a9\u307f\u3092\u304a\u6301\u3061\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<ul>\n<li>\u300c\u5404\u30e1\u30fc\u30ab\u30fc\u3078\u306e\u500b\u5225\u4f9d\u983c\u304c\u9762\u5012\u300d<\/li>\n<li>\u300c\u4fa1\u683c\u3001\u7d0d\u671f\u304c\u30d0\u30e9\u30d0\u30e9\u3067\u7ba1\u7406\u304c\u5927\u5909\u300d<\/li>\n<li>\u300c\u30e1\u30fc\u30ab\u30fc\u3054\u3068\u3067\u57fa\u6e96\u3084\u66f8\u985e\u304c\u7570\u306a\u308b\u305f\u3081\u5185\u5bb9\u3092\u628a\u63e1\u3067\u304d\u306a\u3044\u300d<\/li>\n<\/ul>\n<p>Thermo Fisher Scientific\u3067\u306f\u3001<strong>\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/strong><\/p>\n<p>\u307e\u305f\u3001<strong>ISO,GLP,GMP\u306a\u3069\u54c1\u8cea\u4fdd\u8a3c\u3092\u5fc5\u8981\u3068\u3055\u308c\u308b\u304a\u5ba2\u69d8\u306b\u5f53\u793e\u306e\u8cea\u306e\u9ad8\u3044\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u30b5\u30fc\u30d3\u30b9\u3092\u63d0\u4f9b<\/strong>\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306b\u3064\u3044\u3066\u3001\u300c<strong>\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044<\/strong>\u300d\u3001\u300c<strong>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u30ab\u30bf\u30ed\u30b0\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u305f\u3044<\/strong>\u300d<\/p>\n<p>\u3068\u304a\u8003\u3048\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u306e\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-inquiry.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u30fb\u30ab\u30bf\u30ed\u30b0\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u5e0c\u671b\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u4e0b\u8a18\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc4_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u3092\u307f\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u306f\u3001\u7cbe\u5bc6\u5ea6\u3068\u6b63\u78ba\u5ea6\u306e\u4e21\u65b9\u3066\u3099\u8aa4\u5dee\u306e\u306a\u3044\u3053\u3068\u304b\u3099\u91cd\u8981\u3066\u3099\u3059\u3002\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30b9\u30d8\u309a\u30c3\u30af\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u30d5\u30a1\u30af\u30bf\u304b\u3099\u5f71\u97ff\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u3092\u8a55\u4fa1\u3059\u308b\u4e0a\u3066\u3099\u4e3b\u8981\u306a\u5b9a\u91cf\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3066\u3099\u3059\u3002\u4eca\u56de\u306f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2426,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[41],"division":[],"class_list":{"0":"post-272","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-pipetting","9":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081\" \/>\n<meta property=\"og:description\" content=\"\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u306f\u3001\u7cbe\u5bc6\u5ea6\u3068\u6b63\u78ba\u5ea6\u306e\u4e21\u65b9\u3066\u3099\u8aa4\u5dee\u306e\u306a\u3044\u3053\u3068\u304b\u3099\u91cd\u8981\u3066\u3099\u3059\u3002\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30b9\u30d8\u309a\u30c3\u30af\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u30d5\u30a1\u30af\u30bf\u304b\u3099\u5f71\u97ff\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u3092\u8a55\u4fa1\u3059\u308b\u4e0a\u3066\u3099\u4e3b\u8981\u306a\u5b9a\u91cf\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3066\u3099\u3059\u3002\u4eca\u56de\u306f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-02-04T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T08:09:08+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081\",\"datePublished\":\"2016-02-04T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:09:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/\"},\"wordCount\":56,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-3.jpg\",\"keywords\":[\"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/\",\"name\":\"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-3.jpg\",\"datePublished\":\"2016-02-04T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:09:08+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-3.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-3.jpg\",\"width\":1200,\"height\":630,\"caption\":\"pipetting-guide-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide4\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/","og_locale":"ja_JP","og_type":"article","og_title":"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081","og_description":"\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u306f\u3001\u7cbe\u5bc6\u5ea6\u3068\u6b63\u78ba\u5ea6\u306e\u4e21\u65b9\u3066\u3099\u8aa4\u5dee\u306e\u306a\u3044\u3053\u3068\u304b\u3099\u91cd\u8981\u3066\u3099\u3059\u3002\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30b9\u30d8\u309a\u30c3\u30af\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u30d5\u30a1\u30af\u30bf\u304b\u3099\u5f71\u97ff\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u3092\u8a55\u4fa1\u3059\u308b\u4e0a\u3066\u3099\u4e3b\u8981\u306a\u5b9a\u91cf\u30cf\u309a\u30e9\u30e1\u30fc\u30bf\u3066\u3099\u3059\u3002\u4eca\u56de\u306f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-02-04T00:00:00+00:00","article_modified_time":"2025-07-02T08:09:08+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"7\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081","datePublished":"2016-02-04T00:00:00+00:00","dateModified":"2025-07-02T08:09:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/"},"wordCount":56,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3.jpg","keywords":["\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/","name":"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3.jpg","datePublished":"2016-02-04T00:00:00+00:00","dateModified":"2025-07-02T08:09:08+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3.jpg","width":1200,"height":630,"caption":"pipetting-guide-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide4\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u307f\u3093\u306a\u306b\u4f1d\u3048\u305f\u3044\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306b\u5f71\u97ff\u3059\u308b\u30d5\u30a1\u30af\u30bf\u307e\u3068\u3081"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":41,"label":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":41,"name":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099","slug":"pipetting","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24707,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-manufacturing-battery-development-csm-26009\/","url_meta":{"origin":272,"position":0},"title":"\u96fb\u6c60\u88fd\u9020\u306b\u5411\u3051\u305f\u591a\u5c64\u96fb\u6975\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u6280\u8853\u306e\u9032\u5c55","author":"LatB Staff","date":"2026\u5e742\u670824\u65e5","format":false,"excerpt":"\u9ad8\u5ea6\u306a\u96fb\u6975\u8a2d\u8a08\u3068\u3001\u305d\u308c\u304c\u96fb\u6c60\u96fb\u6975\u306e\u6027\u80fd\u304a\u3088\u3073\u52b9\u7387\u306b\u4e0e\u3048\u308b\u5f71\u97ff8inks \u5171\u540c\u5275\u696d\u8005\u517c CEO Dr.\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/02\/battery-manufacturing-battery-development-csm-26009_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":272,"position":1},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":272,"position":2},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24026,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25071\/","url_meta":{"origin":272,"position":3},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2466\uff1a\u6750\u6599\u4f9b\u7d66\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670819\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24627,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/battery-development-semiconductors-lpd-26006\/","url_meta":{"origin":272,"position":4},"title":"\u9078\u3070\u308c\u308b\u7406\u7531\u304c\u3042\u308b\uff1aThermo Scientific\u771f\u7a7a\u30aa\u30fc\u30d6\u30f3\uff5e\u9ad8\u6e29\u30fb\u9ad8\u771f\u7a7a\u304c\u751f\u307f\u51fa\u3059\u3001\u7cbe\u5bc6\u30d7\u30ed\u30bb\u30b9\u3068\u4fe1\u983c\u6027\uff5e","author":"LatB Staff","date":"2026\u5e741\u670830\u65e5","format":false,"excerpt":"\u88fd\u54c1\u3084\u6750\u6599\u306e\u54c1\u8cea\u3092\u9ad8\u3081\u308b\u3046\u3048\u3067\u3001\u4e7e\u71e5\u30fb\u52a0\u71b1\u30fb\u8131\u6ce1\u3068\u3044\u3063\u305f\u30d7\u30ed\u30bb\u30b9\u306f\u6b20\u304b\u305b\u306a\u3044\u8981\u7d20\u3067\u3059\u3002\u305d\u306e\u4e2d\u3067\u3082\u3001\u6e29\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/battery-development_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23425,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25062\/","url_meta":{"origin":272,"position":5},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2465\uff1a\u30d7\u30ed\u30bb\u30b9\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc","author":"LatB Staff","date":"2025\u5e7410\u670820\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/09\/twin-screw-extrusion-extruder-cad-25057_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-3.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/272","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=272"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/272\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2426"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=272"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=272"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=272"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=272"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}