{"id":300,"date":"2016-02-25T00:00:00","date_gmt":"2016-02-25T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/"},"modified":"2025-07-02T17:08:14","modified_gmt":"2025-07-02T08:08:14","slug":"pipetting-guide7","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/","title":{"rendered":"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9"},"content":{"rendered":"<p>\u30d4\u30da\u30c3\u30c8\u3092\u7121\u83cc\u7684\u306b\u4f7f\u7528\u3059\u308b\u306b\u306f\u3001\u6ec5\u83cc\u4f5c\u696d\u304c\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u524d\u56de\u306f\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u304c\u6c5a\u308c\u3066\u3057\u307e\u3063\u305f\u969b\u306e\u6d17\u6d44\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u4eca\u56de\u306f\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099<\/h2>\n<p>\u8010\u71b1\u6027\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30cf\u309a\u30fc\u30c4\u306b\u3064\u3044\u3066\u306f\u3001<strong>\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u304b\u3099\u3082\u3063\u3068\u3082\u30b7\u30f3\u30d5\u309a\u30eb\u306a\u6ec5\u83cc\u6cd5<\/strong>\u3066\u3099\u3059\u3002 \u6ec5\u83cc\u306f\u3001\u53d6\u6271\u8aac\u660e\u66f8\u306e\u6307\u793a\u306b\u3057\u305f\u304b\u3099\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002 \u7121\u83cc\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u306f\u300120\u5206\u9593\u3001121\u00b0C\u3092\u7dad\u6301\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<ul>\n<li>Finnpipette\u306e\u30d5\u30eb\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u30e2\u30c6\u3099\u30eb:<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4642080?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">F2<\/a>(\u5206\u89e3\u3057\u306a\u304f\u3066\u3082\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059)<\/li>\n<li>\u30c1\u30c3\u30d5\u309a\u30b3\u30fc\u30f3\u304b\u3099\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u53ef\u80fd\u306a\u30e2\u30c6\u3099\u30eb:F1\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4661050N?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Novus<\/a><\/li>\n<\/ul>\n<p><strong>\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u6ec5\u83cc\u3092\u884c\u3046\u5834\u5408\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3084\u30c1\u30c3\u30d5\u309a\u3078\u306e\u30bf\u3099\u30e1\u30fc\u30b7\u3099\u3092\u907f\u3051\u308b\u305f\u3081\u3001\u4ee5\u4e0b\u306e\u624b\u9806\u306b\u3057\u305f\u304b\u3099\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/strong><\/p>\n<h3>Finnpipette<\/h3>\n<ol>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4642080?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Finnpipette F2<\/a>\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3092\u5206\u89e3\u3057\u306a\u304f\u3066\u3082121\u00b0C\u300120\u5206\u9593\u306e\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u304b\u3099\u53ef\u80fd\u3066\u3099\u3059\u3002 Finnpipette F1\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4661050N?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Novus<\/a>\u306a\u3068\u3099\u306e\u30e2\u30c6\u3099\u30eb\u306f\u30c1\u30c3\u30d5\u309a\u30b3\u30fc\u30f3\u306e\u307f\u3092\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u306b\u304b\u3051\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<li>\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u7d42\u4e86\u5f8c\u3001\u4f7f\u7528\u3059\u308b\u524d\u306b\u5c11\u306a\u304f\u3068\u30822\u6642\u9593\u4ee5\u4e0a\u9759\u7f6e\u3057\u3001\u5ba4\u6e29\u306b\u623b\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<li>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3092\u691c\u5b9a\u3057\u3001\u5fc5\u8981\u3066\u3099\u3042\u308c\u306f\u3099\u8abf\u6574\u3092\u884c\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<\/ol>\n<h3>Finntip<\/h3>\n<p>\u30e9\u30c3\u30af\u3053\u3099\u3068121\u00b0C\u300120\u5206\u9593\u306e\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u306b\u304b\u3051\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u76f4\u5f8c\u306f\u30c1\u30c3\u30d5\u309a\u304b\u3099\u6e7f\u3063\u3066\u3044\u307e\u3059\u3002 \u3066\u3099\u304d\u308c\u306f\u3099\u4e00\u6669\u4ee5\u4e0a\u304a\u3044\u3066\u30c1\u30c3\u30d5\u309a\u304b\u3099\u4e7e\u71e5\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u304b\u3089\u4f7f\u7528\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h2>\u85ac\u54c1\u306b\u3088\u308b\u6d88\u6bd2\u304a\u3088\u3072\u3099\u6ec5\u83cc<\/h2>\n<p><strong>\u85ac\u54c1\u306b\u3088\u308b\u6d88\u6bd2\u307e\u305f\u306f\u6ec5\u83cc\u306f\u3001\u8868\u9762\u306e\u6c5a\u67d3\u9664\u53bb\u3084\u3001\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u304b\u3099\u3066\u3099\u304d\u306a\u3044\u304b\u307e\u305f\u306f\u5b9f\u969b\u7684\u3066\u3099\u306a\u3044\u5099\u54c1\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/strong>\u6d88\u6bd2\u30fb\u6ec5\u83cc\u7528\u306e\u85ac\u54c1\u306e\u9078\u629e\u306f\u3001\u5bfe\u8c61\u3068\u306a\u308b\u5fae\u751f\u7269\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u307e\u305f\u3001<strong>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30cf\u309a\u30fc\u30c4\u306e\u6750\u8cea\u306e\u5316\u5b66\u7684\u9069\u5408\u6027(\u8010\u85ac\u54c1\u6027)\u3082\u8003\u616e\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/strong>\u4e0b\u8a18\u306b\u6d88\u6bd2\u30fb\u6ec5\u83cc\u6761\u4ef6\u306e\u4f8b\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<p>\u30c1\u30c3\u30d5\u309a\u30b3\u30fc\u30f3\u304a\u3088\u3072\u3099\u30c1\u30c3\u30d5\u309a\u30a4\u30b7\u3099\u30a7\u30af\u30bf\u306e\u4e0b\u90e8\u30cf\u309a\u30fc\u30c4\u3092\u85ac\u54c1\u3066\u3099\u6c5a\u67d3\u9664\u53bb\u3059\u308b\u5834\u5408\u3001\u53d6\u6271\u8aac\u660e\u66f8\u306b\u3057\u305f\u304b\u3099\u3063\u3066\u53d6\u308a\u5916\u3057\u3066\u304f\u3060\u3055\u3044\u3002Finnpipette F1\u306e\u30cf\u30f3\u30c8\u3099\u30eb\u304a\u3088\u3072\u3099\u30d5\u309a\u30c3\u30b7\u30e5\u30db\u3099\u30bf\u30f3\u306f\u6297\u83cc\u6027\u30db\u309a\u30ea\u30de\u30fc\u88fd\u3066\u3099\u3059\u3002 \u4e00\u822c\u7684\u306a\u30e9\u30db\u3099\u306e\u6d88\u6bd2\u5264\u3001\u4f8b\u3048\u306f\u309970%\u30a8\u30bf\u30ce\u30fc\u30eb\u30845%\u6b21\u4e9c\u5869\u7d20\u9178\u30ca\u30c8\u30ea\u30a6\u30e0\u3092\u8868\u9762\u306e\u6d88\u6bd2\u306b\u4f7f\u3046\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u3001\u6297\u83cc\u52b9\u679c\u306b\u5f71\u97ff\u3082\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<table>\n<tbody>\n<tr>\n<td><\/td>\n<td>\u6d88\u6bd2(20\u00b0C)<\/td>\n<td>\u6ec5\u83cc(20\u00b0C)<\/td>\n<td>Finnpipette\u306e\u8010\u85ac\u54c1\u6027<\/td>\n<\/tr>\n<tr>\n<td>\u904e\u9178\u5316\u6c34\u7d20(7.5%)<\/td>\n<td>30\u5206<\/td>\n<td>30\u5206<\/td>\n<td>\u25ce<\/td>\n<\/tr>\n<tr>\n<td>\u30af\u3099\u30eb\u30bf\u30fc\u30eb\u30a2\u30eb\u30c6\u3099\u30d2\u30c8\u3099(2.5%)<\/td>\n<td>20 \u301c 90\u5206<\/td>\n<td>10\u6642\u9593<\/td>\n<td>\u25ce<\/td>\n<\/tr>\n<tr>\n<td>\u6b21\u4e9c\u5869\u7d20\u9178\u30ca\u30c8\u30ea\u30a6\u30e0(5%)<\/td>\n<td>20\u5206<\/td>\n<td>&#8211;<\/td>\n<td>\u25ce<\/td>\n<\/tr>\n<tr>\n<td>\u30a8\u30bf\u30ce\u30fc\u30eb(70%)<\/td>\n<td>10 \u301c 30\u5206<\/td>\n<td>&#8211;<\/td>\n<td>\u25ce<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>\u305d\u306e\u4ed6\u306e\u6ec5\u83cc\u65b9\u6cd5<\/h2>\n<p>Finnpipette (\u96fb\u52d5\u30d2\u309a\u30d8\u309a\u30c3\u30c8<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4661050N?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Finnpipette Novus<\/a>\u306e\u30cf\u30f3\u30c8\u3099\u30eb\u306f\u9664\u304f) \u306f<strong>STERRAD (\u4f4e\u6e29\u30d5\u309a\u30e9\u30b9\u3099\u30de\u6ec5\u83cc\u30b7\u30b9\u30c6\u30e0) \u304a\u3088\u3072\u3099\u30a8\u30c1\u30ec\u30f3\u30aa\u30ad\u30b5\u30a4\u30c8\u3099\u51e6\u7406\u306b\u3088\u308b\u6ec5\u83cc\u304b\u3099\u53ef\u80fd<\/strong>\u3066\u3099\u3059\u3002\u6ec5\u83cc\u51e6\u7406\u306e\u524d\u306b\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3092\u5206\u89e3\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h2>UV\u8010\u6027<\/h2>\n<p>Finnpipette F1\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4642080?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">F2<\/a>\u306fUV\u8010\u6027\u306e\u6750\u6599\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u7d2b\u5916\u7dda\u306e\u5f71\u97ff\u306b\u3088\u3063\u3066\u30cf\u30f3\u30c8\u3099\u30eb\u90e8\u5206\u306e\u8272\u304b\u3099\u9ec4\u5909\u3059\u308b\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u5185\u90e8\u306e\u30cf\u309a\u30fc\u30c4\u306b\u7d2b\u5916\u7dda\u3092\u7167\u5c04\u3057\u305f\u3068\u304d\u306f\u3001\u30d2\u309a\u30b9\u30c8\u30f3\u3084O-\u30ea\u30f3\u30af\u3099\u306b\u30af\u3099\u30ea\u30fc\u30b9\u3092\u5857\u5e03\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<p>\u3044\u304b\u304c\u3067\u3057\u305f\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<p>\u7121\u83cc\u4f5c\u696d\u4e2d\u306b\u5927\u4e8b\u306a\u30b5\u30f3\u30d7\u30eb\u304c\u30b3\u30f3\u30bf\u30df\u3057\u3066\u3057\u307e\u3046\u524d\u306b\u3001\u30d4\u30da\u30c3\u30c8\u3092\u6ec5\u83cc\u3057\u3066\u304a\u304d\u307e\u3057\u3087\u3046\uff01<\/p>\n<h3>GLP\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/h3>\n<p>\u5f53\u793e\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c4\u30fc\u30eb\u306e\u9078\u629e\u3084\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u9069\u3057\u305f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c6\u30af\u30cb\u30c3\u30af\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u308b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/glp-guide-form.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h3>\u3010\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u5c55\u958b\u4e2d\u3011\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u53ef\u80fd\u3067\u3059\uff01<\/h3>\n<p>\u666e\u6bb5\u306e\u5b9f\u9a13\u306b\u6b20\u304b\u305b\u306a\u3044\u30d4\u30da\u30c3\u30c8\u306e\u6821\u6b63\u306b\u3064\u3044\u3066\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u60a9\u307f\u3092\u304a\u6301\u3061\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<ul>\n<li>\u300c\u5404\u30e1\u30fc\u30ab\u30fc\u3078\u306e\u500b\u5225\u4f9d\u983c\u304c\u9762\u5012\u300d<\/li>\n<li>\u300c\u4fa1\u683c\u3001\u7d0d\u671f\u304c\u30d0\u30e9\u30d0\u30e9\u3067\u7ba1\u7406\u304c\u5927\u5909\u300d<\/li>\n<li>\u300c\u30e1\u30fc\u30ab\u30fc\u3054\u3068\u3067\u57fa\u6e96\u3084\u66f8\u985e\u304c\u7570\u306a\u308b\u305f\u3081\u5185\u5bb9\u3092\u628a\u63e1\u3067\u304d\u306a\u3044\u300d<\/li>\n<\/ul>\n<p>Thermo Fisher Scientific\u3067\u306f\u3001<strong>\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/strong><\/p>\n<p>\u307e\u305f\u3001<strong>ISO,GLP,GMP\u306a\u3069\u54c1\u8cea\u4fdd\u8a3c\u3092\u5fc5\u8981\u3068\u3055\u308c\u308b\u304a\u5ba2\u69d8\u306b\u5f53\u793e\u306e\u8cea\u306e\u9ad8\u3044\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u30b5\u30fc\u30d3\u30b9\u3092\u63d0\u4f9b<\/strong>\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306b\u3064\u3044\u3066\u3001\u300c<strong>\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044<\/strong>\u300d\u3001\u300c<strong>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u30ab\u30bf\u30ed\u30b0\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u305f\u3044<\/strong>\u300d<\/p>\n<p>\u3068\u304a\u8003\u3048\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u306e\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-inquiry.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u30fb\u30ab\u30bf\u30ed\u30b0\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u5e0c\u671b\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u4e0b\u8a18\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc7_Social_LAB\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u3092\u307f\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u3092\u7121\u83cc\u7684\u306b\u4f7f\u7528\u3059\u308b\u306b\u306f\u3001\u6ec5\u83cc\u4f5c\u696d\u304c\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2470,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[41],"division":[],"class_list":["post-300","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-pipetting","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9\" \/>\n<meta property=\"og:description\" content=\"\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u3092\u7121\u83cc\u7684\u306b\u4f7f\u7528\u3059\u308b\u306b\u306f\u3001\u6ec5\u83cc\u4f5c\u696d\u304c\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-02-25T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T08:08:14+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"6\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9\",\"datePublished\":\"2016-02-25T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:08:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/\"},\"wordCount\":38,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-6.jpg\",\"keywords\":[\"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/\",\"name\":\"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-6.jpg\",\"datePublished\":\"2016-02-25T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:08:14+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-6.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-6.jpg\",\"width\":1200,\"height\":630,\"caption\":\"pipetting-guide-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide7\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/","og_locale":"ja_JP","og_type":"article","og_title":"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9","og_description":"\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u3092\u7121\u83cc\u7684\u306b\u4f7f\u7528\u3059\u308b\u306b\u306f\u3001\u6ec5\u83cc\u4f5c\u696d\u304c\u5fc5\u8981\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u30de\u30a4\u30af\u30ed\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u6ce8\u610f\u70b9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-02-25T00:00:00+00:00","article_modified_time":"2025-07-02T08:08:14+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"6\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9","datePublished":"2016-02-25T00:00:00+00:00","dateModified":"2025-07-02T08:08:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/"},"wordCount":38,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6.jpg","keywords":["\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/","name":"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6.jpg","datePublished":"2016-02-25T00:00:00+00:00","dateModified":"2025-07-02T08:08:14+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6.jpg","width":1200,"height":630,"caption":"pipetting-guide-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide7\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u30b3\u30f3\u30bf\u30df\u3059\u308b\u524d\u306b\u8aad\u3093\u3067\u304a\u304f\u3079\u304d\u3001\u30d4\u30da\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u3068\u305d\u306e\u6ce8\u610f\u70b9"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":41,"label":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":41,"name":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099","slug":"pipetting","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":300,"position":0},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24968,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-protein-expression-bid-ts-mbr-26012_\/","url_meta":{"origin":300,"position":1},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046","author":"LatB Staff","date":"2026\u5e743\u670816\u65e5","format":false,"excerpt":"\u5206\u5b50\u751f\u7269\u5b66\u306e\u9ece\u660e\u671f\u3092\u652f\u3048\u3066\u304d\u305f\u5927\u8178\u83cc\uff08Escherichia coli\uff09\u3067\u3059\u304c\u3001\u8fd1\u5e74\u3067\u306f\u5168\u304f\u6271\u308f\u306a\u3044\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/cloning-protein-expression-bid-ts-mbr-26012_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25000,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/nalgene-safety-control-lpd-26013\/","url_meta":{"origin":300,"position":2},"title":"\u30e9\u30dc\u30dc\u30c8\u30eb\u306e\u8010\u85ac\u54c1\u6027\u3068\u6c17\u5bc6\u6027\u3068\u306f\uff1f\uff5e \u610f\u5916\u3068\u77e5\u3089\u306a\u3044\u57fa\u672c\u306e\u8a71\uff5e","author":"LatB Staff","date":"2026\u5e743\u670826\u65e5","format":false,"excerpt":"\u30dc\u30c8\u30eb\u9078\u3073\u3001\u306a\u3093\u3068\u306a\u304f\u3067\u5927\u4e08\u592b\uff1f \u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30dc\u30c8\u30eb\u306f\u3001\u30dc\u30c8\u30eb\u306e\u6a39\u8102\u3068\u5185\u5bb9\u7269\u306e\u76f8\u6027\u304c\u9069\u5207\u3067\u306a\u3044\u5834\u5408\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/03\/nalgene-safety-control-lpd-26013_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":300,"position":3},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":300,"position":4},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25623,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-flow-cytometry-ts-r-25069\/","url_meta":{"origin":300,"position":5},"title":"\u3010\u7b2c9\u56de\u3011 \u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u89e3\u6790\u7528\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u56de\u53ce","author":"LatB Staff","date":"2026\u5e7410\u670830\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30ca\u30ce\u30b5\u30a4\u30ba\u306e\u5c0f\u80de\uff08\u76f4\u5f8430\uff5e100 nm\uff09\u3067\u3042\u308b\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u3092\u3001\u78c1\u6c17\u30d3\u30fc\u30ba\uff08Invitro\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-6.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/300","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=300"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/300\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2470"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=300"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=300"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=300"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}