{"id":314,"date":"2016-03-10T00:00:00","date_gmt":"2016-03-10T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/"},"modified":"2025-07-02T17:01:17","modified_gmt":"2025-07-02T08:01:17","slug":"pipetting-guide9","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/","title":{"rendered":"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f"},"content":{"rendered":"\n<h2>\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3<\/h2>\n<p>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u306f\u3001<strong>\u8a2d\u5b9a(\u8868\u793a)\u5bb9\u91cf\u3068\u5b9f\u969b\u306e\u5206\u6ce8\u5bb9\u91cf\u3068\u306e\u5dee\u3092\u691c\u5b9a\u3059\u308b\u3053\u3068<\/strong>\u3066\u3099\u3059\u3002\u8abf\u6574(\u30a2\u30b7\u3099\u30e3\u30b9\u30c8\u30e1\u30f3\u30c8) \u306f\u3001\u5b9f\u969b\u306e\u5206\u6ce8\u91cf\u304b\u3099\u898f\u683c\u306b\u9069\u5408\u3059\u308b\u3088\u3046\u306b\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3092\u8abf\u7bc0\u3059\u308b\u3053\u3068\u3066\u3099\u3059\u3002<strong>\u691c\u5b9a\u3068\u8abf\u6574\u3092\u5408\u308f\u305b\u3066\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u3044\u3046\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<\/strong><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-plasticware-supplies\/pipettes-pipette-tips.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Finnpipette<\/a>\u306f\u5168\u3066\u5de5\u5834\u51fa\u8377\u6642\u306b\u7cbe\u88fd\u6c34\u306b\u3088\u308b\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3044\u3001\u5206\u6ce8\u5bb9\u91cf\u304b\u3099\u8abf\u6574\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5de5\u5834\u3066\u3099\u306e\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u3001\u91cd\u91cf\u6cd5\u3066\u3099\u884c\u3044\u307e\u3059\u3002\u5404\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6700\u5927\u5bb9\u91cf\u3068\u6700\u5c0f\u5bb9\u91cf\u306b\u3064\u3044\u3066\u3001\u305d\u308c\u305d\u3099\u308c5\u56de\u3059\u3099\u3064\u5206\u6ce8\u6db2\u306e\u91cd\u91cf\u3092\u6e2c\u5b9a\u3057\u3066\u691c\u5b9a\u3092\u884c\u3044\u307e\u3059\u3002\u3053\u306e\u691c\u5b9a\u7d50\u679c\u306f\u300cCalibration Report\u300d\u3068\u3057\u3066\u5168\u3066\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-plasticware-supplies\/pipettes-pipette-tips.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Finnpipette<\/a>\u306b\u540c\u68b1\u3055\u308c\u307e\u3059\u3002 <strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-plasticware-supplies\/pipettes-pipette-tips.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Finnpipette<\/a>\u306f\u30e6\u30fc\u30b5\u3099\u30fc\u30b5\u30a4\u30c8\u3099\u3066\u3099\u7c21\u5358\u306b\u518d\u691c\u5b9a\u3068\u8abf\u6574\u304b\u3099\u884c\u3048\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/strong><\/p>\n<h3>\u54c1\u8cea\u30b7\u30b9\u30c6\u30e0\u306b\u304a\u3051\u308b\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3<\/h3>\n<p>\u54c1\u8cea\u30b7\u30b9\u30c6\u30e0\u306e\u4e2d\u3066\u3099\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u306e\u76ee\u7684\u306f\u3001\u610f\u56f3\u3057\u305f\u6b63\u78ba\u3055\u3066\u3099\u5206\u6ce8\u304b\u3099\u884c\u308f\u308c\u308b\u3053\u3068\u306e\u4fdd\u8a3c\u3066\u3099\u3059\u3002<strong>\u5b9f\u969b\u306e\u4f5c\u696d\u3066\u3099\u306f\u305d\u3053\u307e\u3066\u3099\u306e\u7cbe\u5ea6\u304b\u3099\u6c42\u3081\u3089\u308c\u3066\u3044\u306a\u3044\u306b\u3082\u304b\u304b\u308f\u3089\u3059\u3099\u3001\u8aa4\u5dee\u306e\u9650\u754c\u5024(\u7cbe\u5ea6\u898f\u683c)\u3092\u3001\u88fd\u9020\u5143\u306e\u898f\u683c\u3068\u540c\u69d8\u306b\u8a2d\u5b9a\u3057\u3066\u3044\u308b\u30b1\u30fc\u30b9\u304b\u3099\u3057\u306f\u3099\u3057\u306f\u3099\u3042\u308a\u307e\u3059\u3002<\/strong>\u3057\u304b\u3057\u3001\u6e29\u5ea6\u3084\u6e7f\u5ea6\u306a\u3068\u3099\u74b0\u5883\u3092\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3057\u3066\u3044\u306a\u3044\u901a\u5e38\u306e\u30e9\u30db\u3099\u3066\u3099\u3001\u88fd\u9020\u5143\u306e\u898f\u683c\u3092\u6e80\u305f\u3059\u3053\u3068\u306f\u304b\u306a\u308a\u56f0\u96e3\u3066\u3099\u3042\u308b\u3053\u3068\u306b\u3053\u3099\u7559\u610f\u304f\u305f\u3099\u3055\u3044\u3002\u5de5\u5834\u3066\u3099\u306f\u3001\u6e29\u5ea6\u3084\u6e7f\u5ea6\u304b\u3099\u5b89\u5b9a\u3057\u305f\u74b0\u5883\u306b\u304a\u3044\u3066\u3001\u84b8\u7559\u6c34\u307e\u305f\u306f\u30a4\u30aa\u30f3\u4ea4\u63db\u6c34\u3092\u7528\u3044\u3066\u691c\u5b9a\u3092\u884c\u3063\u3066\u3044\u307e\u3059\u3002<strong>\u4f7f\u7528\u76ee\u7684\u3084\u30e9\u30db\u3099\u306e\u74b0\u5883\u3092\u8003\u616e\u3057\u3001\u8a31\u5bb9\u3066\u3099\u304d\u308b\u898f\u683c\u3092\u305d\u308c\u305d\u3099\u308c\u8a2d\u5b9a\u3059\u308b\u3078\u3099\u304d<\/strong>\u3066\u3099\u3057\u3087\u3046\u3002\u3042\u308b\u3044\u306f\u3001\u4f8b\u3048\u306f\u3099EN ISO8655\u306e\u3088\u3046\u306a\u898f\u683c\u306e\u5024\u30922\u500d\u3059\u308b\u3068\u3044\u3046\u3088\u3046\u306a\u65b9\u6cd5\u3082\u3042\u308a\u307e\u3059\u3002<strong>\u9ad8\u3044\u7cbe\u5ea6\u304b\u3099\u8981\u6c42\u3055\u308c\u308b\u3088\u3046\u306a\u5834\u5408\u306f\u3001\u5de5\u5834\u3068\u540c\u69d8\u306e\u691c\u5b9a\u74b0\u5883\u3092\u6574\u3048\u308b\u5fc5\u8981\u304b\u3099\u3042\u308b<\/strong>\u3066\u3099\u3057\u3087\u3046\u3002<\/p>\n<h3>EN ISO8655\u306b\u57fa\u3064\u3099\u304f\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u898f\u683c<\/h3>\n<p>EN ISO 8655\u898f\u683c\u306b\u306f\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6b63\u78ba\u5ea6\u3068\u7cbe\u5bc6\u5ea6\u306e\u8a31\u5bb9\u7bc4\u56f2\u304b\u3099\u7d76\u5bfe\u5024\u3068\u76f8\u5bfe\u5024\u3066\u3099\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u305d\u3099\u308c\u306e\u5024\u306f\u3001\u7a7a\u6c17\u7f6e\u63db\u65b9\u5f0f\u3066\u3099\u3001\u5bb9\u91cf\u56fa\u5b9a\u306e\u30b7\u30f3\u30af\u3099\u30eb\u30c1\u30e3\u30f3\u30cd\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5024\u3068\u3057\u3066\u898f\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5bb9\u91cf\u53ef\u5909\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5834\u5408\u3001\u540d\u76ee\u5bb9\u91cf(nominal volume)\u306f\u6700\u5927\u5bb9\u91cf\u306b\u8a72\u5f53\u3057\u307e\u3059\u3002\u540d\u76ee\u5bb9\u91cf\u306e\u898f\u683c(\u03bcl)\u304b\u3099\u305d\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5168\u3066\u306e\u5bb9\u91cf\u306b\u9069\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n<p>\u4f8b:10-100\u03bcl\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5834\u5408(100\u03bcl\u306e\u898f\u683c\u5024\u304b\u3099\u5168\u3066\u306e\u5bb9\u91cf\u306b\u9069\u7528\u3055\u308c\u308b)<br \/>\n\u6b63\u78ba\u5ea6(ACC)\u00b10.8\u03bcl<br \/>\n\u7cbe\u5bc6\u5ea6(SD)0.3\u03bcl<\/p>\n<h2>\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u306b\u5fc5\u8981\u306a\u6a5f\u5668\u3068\u691c\u5b9a\u74b0\u5883<\/h2>\n<h3>\u5929\u79e4<\/h3>\n<p>\u5206\u6790\u7528\u5929\u79e4\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u5929\u79e4\u306e\u611f\u91cf\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u691c\u5b9a\u5bb9\u91cf\u306b\u5408\u308f\u305b\u3066\u9078\u629e\u3057\u307e\u3059\u3002<\/p>\n<table>\n<tbody>\n<tr>\n<td>\u5bb9\u91cf\u7bc4\u56f2<\/td>\n<td>\u6700\u5c0f\u8868\u793a(\u611f\u91cf)<\/td>\n<\/tr>\n<tr>\n<td>10\u03bcl\u672a\u6e80<\/td>\n<td>0.001mg<\/td>\n<\/tr>\n<tr>\n<td>10-100\u03bcl<\/td>\n<td>0.01mg<\/td>\n<\/tr>\n<tr>\n<td>100\u03bcl\u8d85<\/td>\n<td>0.1mg<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u691c\u5b9a\u6db2<\/h3>\n<p>\u901a\u5e38\u3001<strong>\u84b8\u7559\u6c34\u307e\u305f\u306f\u30a4\u30aa\u30f3\u4ea4\u63db\u6c34\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/strong><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/lab-plasticware-supplies\/pipettes-pipette-tips.html?CID=Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Finnpipette<\/a>\u3066\u3099\u306fISO 3696\u898f\u683c\u201cGrade 3\u201d\u306b\u9069\u5408\u3059\u308b\u7cbe\u88fd\u6c34\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002<strong>\u691c\u5b9a\u6db2\u306f\u30012\u6642\u9593\u4ee5\u4e0a\u524d\u304b\u3089\u691c\u5b9a\u5ba4(\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u30eb\u30fc\u30e0)\u306b\u7f6e\u304d\u3001\u6db2\u6e29\u304b\u3099\u5b89\u5b9a\u3057\u3066\u304b\u3089\u691c\u5b9a\u3092\u884c\u3044\u307e\u3059\u3002<\/strong><\/p>\n<h3>\u691c\u5b9a\u74b0\u5883<\/h3>\n<p>\u691c\u5b9a\u306f\u3001\u901a<strong>\u6c17\u306e\u306a\u3044\u300120\u00b0C\u301c25\u00b0C\u306e\u6052\u6e29\u5ba4(\u00b10.5\u00b0C)\u3066\u3099\u5b9f\u65bd<\/strong>\u3057\u307e\u3059\u3002<strong>\u76f8\u5bfe\u6e7f\u5ea6\u306f50%\u4ee5\u4e0a\u5fc5\u8981<\/strong>\u3066\u3099\u3059\u3002\u7279\u306b50\u03bcl\u4ee5\u4e0b\u306e\u5bb9\u91cf\u3066\u3099\u306f\u3001\u3066\u3099\u304d\u308b\u305f\u3099\u3051\u9ad8\u6e7f\u5ea6\u306e\u74b0\u5883\u306b\u3057\u3066\u3001\u84b8\u767a\u306e\u5f71\u97ff\u3092\u9632\u3044\u3066\u3099\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<ul>\n<li>\u691c\u5b9a\u3059\u308b\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3001\u691c\u5b9a\u306b\u4f7f\u7528\u3059\u308b\u30c1\u30c3\u30d5\u309a\u3084\u691c\u5b9a\u6db2\u306f\u691c\u5b9a\u5ba4\u3068\u540c\u3057\u3099\u6e29\u5ea6\u306b\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<li>\u6b63\u78ba\u306a\u691c\u5b9a\u3092\u884c\u3046\u305f\u3081\u3001\u65b0\u3057\u3044\u30c1\u30c3\u30d5\u309a\u3092\u4f7f\u7528\u3057\u3001\u6700\u521d\u306b3-5\u56de\u3001\u691c\u5b9a\u6db2\u306e\u5438\u6392\u3092\u884c\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<li>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u306f\u5b9a\u671f\u7684\u306b\u5b9f\u65bd\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u4f7f\u7528\u983b\u5ea6\u3084\u4f7f\u7528\u76ee\u7684\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u304b\u3099\u3001\u5c11\u306a\u304f\u3068\u3082\u5e74\u306b1\u56de\u4ee5\u4e0a\u884c\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<\/ul>\n<h3>\u691c\u5b9a<\/h3>\n<ul>\n<li>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3001\u30c1\u30c3\u30d5\u309a\u3001\u691c\u5b9a\u6db2\u306f\u30012\u6642\u9593\u4ee5\u4e0a\u524d\u304b\u3089\u691c\u5b9a\u5ba4\u306b\u7f6e\u304d\u3001\u6e29\u5ea6\u3092\u5b89\u5b9a\u3055\u305b\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<li>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306f\u5b9f\u969b\u306b\u4f7f\u7528\u3059\u308b\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u6cd5\u3066\u3099\u691c\u5b9a\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<li>\u5bb9\u91cf\u53ef\u5909\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5834\u5408\u3001\u4e0b\u8a18\u306e2\u3064\u306e\u5bb9\u91cf\u3066\u3099\u691c\u5b9a\u3057\u307e\u3059\u3002\n<ul>\n<li>\u6700\u5927\u5bb9\u91cf(\u540d\u76ee\u5bb9\u91cf)<\/li>\n<li>\u6700\u5c0f\u5bb9\u91cf\u307e\u305f\u306f\u6700\u5927\u5bb9\u91cf\u306e10%\u306e\u3046\u3061\u3044\u3059\u3099\u308c\u304b\u5927\u304d\u3044\u65b9\uff08\u4f8b:\u5bb9\u91cf\u30ec\u30f3\u30b7\u30990.5-10\u03bcl\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5834\u5408\u300110\u03bcl\u304a\u3088\u3072\u30991\u03bcl\u3066\u3099\u691c\u5b9a\uff09<\/li>\n<\/ul>\n<\/li>\n<li>\u30de\u30eb\u30c1\u30c1\u30e3\u30f3\u30cd\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3066\u3099\u306f\u3001\u5de6\u53f3\u4e21\u7aef\u306e\u30c1\u30e3\u30f3\u30cd\u30eb\u3092\u305d\u308c\u305d\u3099\u308c\u4e0a\u8a18\u306e2\u3064\u306e\u5bb9\u91cf\u3066\u3099\u691c\u5b9a\u3057\u307e\u3059\u3002<\/li>\n<li>\u305d\u308c\u305d\u3099\u308c\u306e\u691c\u5b9a\u5bb9\u91cf\u3066\u30994~10\u56de\u3059\u3099\u3064\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u3092\u884c\u3044\u30011\u56de\u3053\u3099\u3068\u306b\u5929\u79e4\u3066\u3099\u91cd\u91cf\u3092\u6e2c\u5b9a\u3057\u307e\u3059\u3002<\/li>\n<li>\u6e2c\u5b9a\u5024\u304b\u3089\u3001\u5f8c\u8ff0\u306e\u5f0f\u306b\u3088\u308a\u6b63\u78ba\u5ea6(A)\u3068\u7cbe\u5bc6\u5ea6(\u518d\u73fe\u6027\u3001S\u307e\u305f\u306fCV)\u3092\u7b97\u51fa\u3057\u307e\u3059\u3002<\/li>\n<li>\u7d50\u679c\u304b\u3099\u898f\u683c\u7bc4\u56f2\u306b\u5165\u3089\u306a\u3044\u5834\u5408\u306f\u3001\u8abf\u6574\u3092\u884c\u3063\u305f\u5f8c\u3001\u518d\u5ea6\u691c\u5b9a\u3092\u884c\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n<h2>\u8a08\u7b97\u5f0f<\/h2>\n<h3>\u91cd\u91cf\u304b\u3089\u5bb9\u91cf\u3078\u306e\u5909\u63db<\/h3>\n<p>$${ V }=\\left( w+{ e } \\right) \\times Z$$<br \/>\nV = \u5bb9\u91cf(\u03bcl)<br \/>\nw = \u91cd\u91cf(mg)<br \/>\ne = \u84b8\u767a\u306b\u3088\u308b\u6e1b\u91cf(mg)<br \/>\nZ = \u5909\u63db\u4fc2\u6570<\/p>\n<p>\u84b8\u767a\u306b\u3088\u308b\u6e1b\u91cf\u306f\u3001\u7279\u306b\u4f4e\u5bb9\u91cf\u3066\u3099\u6709\u610f\u306e\u5f71\u97ff\u3092\u53ca\u307b\u3099\u3059\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u6e1b\u91cf\u5206\u3092\u6e2c\u5b9a\u3059\u308b\u306b\u306f\u3001\u98a8\u888b\u3092\u6e2c\u5b9a\u3057\u305f\u5bb9\u5668\u306b\u7cbe\u88fd\u6c34\u3092\u5206\u6ce8\u3057\u3001\u91cd\u91cf\u3092\u8a18\u9332\u3057\u3001\u30b9\u30c8\u30c3\u30d5\u309a\u30a6\u30a9\u30c3\u30c1\u3092\u62bc\u3057\u307e\u3059\u300230\u79d2\u5f8c\u306e\u91cd\u91cf\u3092\u8aad\u307f\u53d6\u308a\u3001\u6e1b\u5c11\u304b\u3099\u3068\u3099\u306e\u304f\u3089\u3044\u306b\u306a\u308b\u304b\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002\u901a\u5e38\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u64cd\u4f5c\u306f10\u79d2\u7a0b\u5ea6\u3066\u3099\u3001\u91cd\u91cf\u306e\u6e1b\u5c11\u306f2mg\u524d\u5f8c\u3066\u3099\u3059\u3002\u84b8\u767a\u30c8\u30e9\u30c3\u30d5\u309a\u3084\u5bb9\u5668\u306e\u30ab\u30cf\u3099\u30fc\u3092\u4f7f\u7528\u3059\u308c\u306f\u3099\u3001\u84b8\u767a\u5206\u306e\u88dc\u6b63\u306f\u5fc5\u8981\u3042\u308a\u307e\u305b\u3093\u3002\u5909\u63db\u4fc2\u6570Z\u306f\u3001\u691c\u5b9a\u74b0\u5883\u306e\u6c17\u6e29\u3068\u6c17\u5727\u306b\u3088\u3063\u3066\u7570\u306a\u308b\u5bc6\u5ea6\u3092\u7b97\u5b9a\u3059\u308b\u305f\u3081\u306e\u4fc2\u6570\u3066\u3099\u3059\u3002\u4e0b\u8a18\u306e\u5909\u63db\u4fc2\u6570\u8868\u3092\u53c2\u7167\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h3>\u6b63\u78ba\u5ea6(Accuracy)<\/h3>\n<p>\u6b63\u78ba\u5ea6\u306f\u3001\u305d\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5b9f\u969b\u306e\u5206\u6ce8\u91cf\u3068\u3001\u8a2d\u5b9a(\u8868\u793a)\u5bb9\u91cf\u3068\u306e\u5dee\u7570\u3092\u793a\u3057\u307e\u3059\u3002<br \/>\n$$A=V-{ V }_{ 0 }$$<br \/>\nA = \u6b63\u78ba\u5ea6<br \/>\nV = \u5e73\u5747\u5024<br \/>\nV<sub>0<\/sub>=\u8868\u793a\u5bb9\u91cf<\/p>\n<p>\u6b63\u78ba\u5ea6\u306f\u3001\u76f8\u5bfe\u7684\u306a\u5024\u3068\u3057\u3066\u8868\u3059\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<br \/>\n$$A\uff05=100\uff05\\times \\frac { A }{ { V }_{ 0 } } $$<\/p>\n<h3>\u7cbe\u5bc6\u5ea6(Precision)<\/h3>\n<p>\u7cbe\u5bc6\u5ea6\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u306e\u518d\u73fe\u6027\u3092\u793a\u3059\u3082\u306e\u3066\u3099\u3001\u6a19\u6e96\u504f\u5dee(S)\u307e\u305f\u306f\u5909\u52d5\u4fc2\u6570(CV)\u3068\u3057\u3066\u8868\u3055\u308c\u307e\u3059\u3002\u7cbe\u5bc6\u5ea6\u306b\u306f\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u305f\u3099\u3051\u3066\u3099\u306a\u304f\u3001\u5404\u65bd\u8a2d\u3066\u3099\u5b9f\u65bd\u3055\u308c\u3066\u3044\u308b\u64cd\u4f5c\u624b\u9806\u3084\u3001\u62c5\u5f53\u8005\u306e\u719f\u7df4\u5ea6\u3082\u5927\u304d\u306a\u5f71\u97ff\u3092\u53ca\u307b\u3099\u3057\u307e\u3059\u3002<br \/>\n$$S=\\sqrt { \\frac { { \\sum _{ i=1 }^{ n } }{ \\left( { V }_{ i }-\\bar { V } \\right) }^{ 2 } }{ n-1 } }$$<br \/>\n\u6a19\u6e96\u504f\u5dee\u306f\u3001CV\u5024\u3068\u3057\u3066\u76f8\u5bfe\u7684\u306b\u8868\u3059\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002<br \/>\n$$CV=100\uff05\\times \\frac { S }{ { V } }$$<\/p>\n<h2>\u30d4\u30da\u30c3\u30c8\u306e\u8abf\u6574\u65b9\u6cd5<\/h2>\n<p>\u691c\u5b9a\u7d50\u679c\u304b\u3099\u898f\u683c\u5185\u306b\u5165\u3089\u306a\u3044\u5834\u5408\u3001\u8abf\u6574\u3092\u884c\u3044\u307e\u3059(\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u53d6\u6271\u8aac\u660e\u66f8\u3092\u53c2\u7167\u3057\u3066\u304f\u305f\u3099\u3055\u3044)\u3002<\/p>\n<h3>\u30de\u30cb\u30e5\u30a2\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8<\/h3>\n<ul>\n<li>\u6700\u5c0f\u5bb9\u91cf\u306b\u30bb\u30c3\u30c8\u3057\u307e\u3059\u3002<\/li>\n<li>\u4ed8\u5c5e\u306e\u30b5\u30fc\u30d2\u3099\u30b9\u30c4\u30fc\u30eb\u3092\u30cf\u30f3\u30c8\u3099\u30eb\u4e0a\u7aef\u306b\u3042\u308b\u6e9d\u306b\u5dee\u3057\u8fbc\u307f\u307e\u3059\u3002<\/li>\n<li>\u5bb9\u91cf\u3092\u5897\u3084\u3059\u5834\u5408\u306f\u6642\u8a08\u56de\u308a\u3001\u6e1b\u3089\u3059\u5834\u5408\u306f\u53cd\u6642\u8a08\u56de\u308a\u306b\u30b5\u30fc\u30d2\u3099\u30b9\u30c4\u30fc\u30eb\u3092\u56de\u3057\u307e\u3059\u3002<\/li>\n<li>\u518d\u5ea6\u691c\u5b9a\u3092\u884c\u3063\u3066\u898f\u683c\u306b\u9069\u5408\u3059\u308b\u304b\u3068\u3099\u3046\u304b\u78ba\u8a8d\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<\/ul>\n<h3>\u96fb\u52d5\u30d2\u309a\u30d8\u309a\u30c3\u30c8(Finnpipette Novus)<\/h3>\n<ul>\n<li>MENU&gt;OPTIONS&gt;CALIBRATE\u3092\u9078\u629e\u3057\u307e\u3059\u3002<\/li>\n<li>\u901a\u5e38\u306fTWO POINTS(\u7279\u5b9a\u306e\u5bb9\u91cf\u3066\u3099\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u5834\u5408\u306fONE POINT)\u3092\u9078\u629e\u3057\u307e\u3059\u3002<\/li>\n<li>\u753b\u9762\u306bTARGET\u306e\u5024\u304b\u3099\u8868\u793a\u3055\u308c\u307e\u3059\u3002<\/li>\n<li>EDIT\u3092\u62bc\u3059\u3068\u8868\u793a\u304b\u3099ACTUAL\u306b\u304b\u308f\u308a\u3001\u5bb9\u91cf\u306e\u6570\u5b57\u304b\u3099\u70b9\u6ec5\u3057\u307e\u3059\u3002\u30b9\u30af\u30ed\u30fc\u30eb\u30ad\u30fc\u3066\u3099\u691c\u5b9a\u3066\u3099\u5f97\u3089\u308c\u305f\u5024\u306b\u5909\u66f4\u3057\u3001OK\u3092\u62bc\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<li>SAVE?\u3068\u8868\u793a\u3055\u308c\u307e\u3059\u306e\u3066\u3099\u3001YES\u3092\u62bc\u3057\u307e\u3059\u3002<\/li>\n<li>\u518d\u5ea6\u691c\u5b9a\u3092\u884c\u3063\u3066\u898f\u683c\u306b\u9069\u5408\u3059\u308b\u304b\u3068\u3099\u3046\u304b\u78ba\u8a8d\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/li>\n<\/ul>\n<h2>\u5909\u63db\u4fc2\u6570\u8868<\/h2>\n<p>\u5909\u63db\u4fc2\u6570Z(\u03bcl\/mg)\u306e\u5024\u306f\u6e29\u5ea6\u3068\u6c17\u5727\u306e\u95a2\u6570\u3068\u306a\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u306b\u84b8\u7559\u6c34\u306e\u5909\u63db\u4fc2\u6570\u3092\u793a\u3057\u307e\u3059\u3002<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-17908\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/795316b92fc766b0181f6fef074f03fa.jpg\" alt=\"\" width=\"635\" height=\"772\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/795316b92fc766b0181f6fef074f03fa.jpg 635w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/795316b92fc766b0181f6fef074f03fa-247x300.jpg 247w\" sizes=\"auto, (max-width: 635px) 100vw, 635px\" \/><\/p>\n<h2>ISO8655 \u8aa4\u5dee\u306e\u8a31\u5bb9\u7bc4\u56f2<\/h2>\n<h3>\u30b7\u30f3\u30af\u3099\u30eb\u30c1\u30e3\u30f3\u30cd\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-17910\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/2b530e80c7d0de90885e285c5d798063-1.jpg\" alt=\"\" width=\"552\" height=\"713\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/2b530e80c7d0de90885e285c5d798063-1.jpg 552w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/2b530e80c7d0de90885e285c5d798063-1-232x300.jpg 232w\" sizes=\"auto, (max-width: 552px) 100vw, 552px\" \/><\/p>\n<h3>\u30de\u30eb\u30c1\u30c1\u30e3\u30f3\u30cd\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-17911\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/c8856789ec11ab8b1013037cef6929f9.jpg\" alt=\"\" width=\"662\" height=\"754\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/c8856789ec11ab8b1013037cef6929f9.jpg 662w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/c8856789ec11ab8b1013037cef6929f9-263x300.jpg 263w\" sizes=\"auto, (max-width: 662px) 100vw, 662px\" \/><\/p>\n<h3>\u30b7\u30f3\u30af\u3099\u30eb\u30c1\u30e3\u30f3\u30cd\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8(\u5bb9\u91cf\u56fa\u5b9a)<\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-17912\" src=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg\" alt=\"\" width=\"926\" height=\"506\" srcset=\"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/3a4f695a458cb0ac0aceaa2eb13ac2dd.jpg 926w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/3a4f695a458cb0ac0aceaa2eb13ac2dd-300x164.jpg 300w, https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2016\/03\/3a4f695a458cb0ac0aceaa2eb13ac2dd-768x420.jpg 768w\" sizes=\"auto, (max-width: 926px) 100vw, 926px\" \/><\/p>\n<h3>GLP\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/h3>\n<p>\u5f53\u793e\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c4\u30fc\u30eb\u306e\u9078\u629e\u3084\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u9069\u3057\u305f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c6\u30af\u30cb\u30c3\u30af\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u308b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/glp-guide-form.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc9_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h3>\u3010\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u5c55\u958b\u4e2d\u3011\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u53ef\u80fd\u3067\u3059\uff01<\/h3>\n<p>\u666e\u6bb5\u306e\u5b9f\u9a13\u306b\u6b20\u304b\u305b\u306a\u3044\u30d4\u30da\u30c3\u30c8\u306e\u6821\u6b63\u306b\u3064\u3044\u3066\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u60a9\u307f\u3092\u304a\u6301\u3061\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<ul>\n<li>\u300c\u5404\u30e1\u30fc\u30ab\u30fc\u3078\u306e\u500b\u5225\u4f9d\u983c\u304c\u9762\u5012\u300d<\/li>\n<li>\u300c\u4fa1\u683c\u3001\u7d0d\u671f\u304c\u30d0\u30e9\u30d0\u30e9\u3067\u7ba1\u7406\u304c\u5927\u5909\u300d<\/li>\n<li>\u300c\u30e1\u30fc\u30ab\u30fc\u3054\u3068\u3067\u57fa\u6e96\u3084\u66f8\u985e\u304c\u7570\u306a\u308b\u305f\u3081\u5185\u5bb9\u3092\u628a\u63e1\u3067\u304d\u306a\u3044\u300d<\/li>\n<\/ul>\n<p>Thermo Fisher Scientific\u3067\u306f\u3001<strong>\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/strong><\/p>\n<p>\u307e\u305f\u3001<strong>ISO,GLP,GMP\u306a\u3069\u54c1\u8cea\u4fdd\u8a3c\u3092\u5fc5\u8981\u3068\u3055\u308c\u308b\u304a\u5ba2\u69d8\u306b\u5f53\u793e\u306e\u8cea\u306e\u9ad8\u3044\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u30b5\u30fc\u30d3\u30b9\u3092\u63d0\u4f9b<\/strong>\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306b\u3064\u3044\u3066\u3001\u300c<strong>\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044<\/strong>\u300d\u3001\u300c<strong>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u30ab\u30bf\u30ed\u30b0\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u305f\u3044<\/strong>\u300d<\/p>\n<p>\u3068\u304a\u8003\u3048\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u306e\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-inquiry.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc9_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u30fb\u30ab\u30bf\u30ed\u30b0\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u5e0c\u671b\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u4e0b\u8a18\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc9_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u3092\u307f\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u306f\u3001\u8a2d\u5b9a(\u8868\u793a)\u5bb9\u91cf\u3068\u5b9f\u969b\u306e\u5206\u6ce8\u5bb9\u91cf\u3068\u306e\u5dee\u3092\u691c\u5b9a\u3057\u3001\u5b9f\u969b\u306e\u5206\u6ce8\u91cf\u304c\u898f\u683c\u306b\u9069\u5408\u3059\u308b\u3088\u3046\u306b\u30d4\u30da\u30c3\u30c8\u3092\u8abf\u7bc0\u3059\u308b\u3053\u3068\u3067\u3059\u3002Finnpipette\u306f\u30e6\u30fc\u30b6\u30fc\u30b5\u30a4\u30c9\u3067\u7c21\u5358\u306b\u518d\u691c\u5b9a\u3068\u8abf\u6574\u304c\u884c\u3048\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u305d\u306e\u8a08\u7b97\u5f0f\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2500,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[41],"division":[],"class_list":["post-314","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-pipetting","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f\" \/>\n<meta property=\"og:description\" content=\"\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u306f\u3001\u8a2d\u5b9a(\u8868\u793a)\u5bb9\u91cf\u3068\u5b9f\u969b\u306e\u5206\u6ce8\u5bb9\u91cf\u3068\u306e\u5dee\u3092\u691c\u5b9a\u3057\u3001\u5b9f\u969b\u306e\u5206\u6ce8\u91cf\u304c\u898f\u683c\u306b\u9069\u5408\u3059\u308b\u3088\u3046\u306b\u30d4\u30da\u30c3\u30c8\u3092\u8abf\u7bc0\u3059\u308b\u3053\u3068\u3067\u3059\u3002Finnpipette\u306f\u30e6\u30fc\u30b6\u30fc\u30b5\u30a4\u30c9\u3067\u7c21\u5358\u306b\u518d\u691c\u5b9a\u3068\u8abf\u6574\u304c\u884c\u3048\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u305d\u306e\u8a08\u7b97\u5f0f\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-03-10T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T08:01:17+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"11\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f\",\"datePublished\":\"2016-03-10T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:01:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/\"},\"wordCount\":123,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-8.jpg\",\"keywords\":[\"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/\",\"name\":\"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-8.jpg\",\"datePublished\":\"2016-03-10T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:01:17+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-8.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-8.jpg\",\"width\":1200,\"height\":630,\"caption\":\"pipetting-guide-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide9\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/","og_locale":"ja_JP","og_type":"article","og_title":"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f","og_description":"\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3068\u306f\u3001\u8a2d\u5b9a(\u8868\u793a)\u5bb9\u91cf\u3068\u5b9f\u969b\u306e\u5206\u6ce8\u5bb9\u91cf\u3068\u306e\u5dee\u3092\u691c\u5b9a\u3057\u3001\u5b9f\u969b\u306e\u5206\u6ce8\u91cf\u304c\u898f\u683c\u306b\u9069\u5408\u3059\u308b\u3088\u3046\u306b\u30d4\u30da\u30c3\u30c8\u3092\u8abf\u7bc0\u3059\u308b\u3053\u3068\u3067\u3059\u3002Finnpipette\u306f\u30e6\u30fc\u30b6\u30fc\u30b5\u30a4\u30c9\u3067\u7c21\u5358\u306b\u518d\u691c\u5b9a\u3068\u8abf\u6574\u304c\u884c\u3048\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u306f\u3001\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u305d\u306e\u8a08\u7b97\u5f0f\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-03-10T00:00:00+00:00","article_modified_time":"2025-07-02T08:01:17+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"11\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f","datePublished":"2016-03-10T00:00:00+00:00","dateModified":"2025-07-02T08:01:17+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/"},"wordCount":123,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8.jpg","keywords":["\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/","name":"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8.jpg","datePublished":"2016-03-10T00:00:00+00:00","dateModified":"2025-07-02T08:01:17+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8.jpg","width":1200,"height":630,"caption":"pipetting-guide-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide9\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u96e3\u3057\u305d\u3046\u3067\u96e3\u3057\u304f\u306a\u3044\u5c11\u3057\u96e3\u3057\u3044\u30d4\u30da\u30c3\u30c8\u306e\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u65b9\u6cd5\u3068\u8a08\u7b97\u5f0f"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":41,"label":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":41,"name":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099","slug":"pipetting","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":314,"position":0},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24026,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/twin-screw-extrusion-extruder-cad-25071\/","url_meta":{"origin":314,"position":1},"title":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u2466\uff1a\u6750\u6599\u4f9b\u7d66\u306e\u30dd\u30a4\u30f3\u30c8","author":"LatB Staff","date":"2025\u5e7411\u670819\u65e5","format":false,"excerpt":"\u4e8c\u8ef8\u62bc\u51fa\u6a5f\u306e\u57fa\u790e\u30b7\u30ea\u30fc\u30ba\u3067\u306f\u88c5\u7f6e\u306e\u4ed5\u7d44\u307f\u3084\u7279\u9577\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u8a2d\u5b9a\u3084\u305d\u306e\u610f\u5473\u3001\u5f8c\u5de5\u7a0b\u30aa\u30d7\u30b7\u30e7\u30f3\u3092\u7d44\u307f\u5408\u2026","rel":"","context":"\u305d\u306e\u4ed6","block_context":{"text":"\u305d\u306e\u4ed6","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/else\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/twin-screw-extrusion-extruder-cad-25071_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":314,"position":2},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25623,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-flow-cytometry-ts-r-25069\/","url_meta":{"origin":314,"position":3},"title":"\u3010\u7b2c9\u56de\u3011 \u30d5\u30ed\u30fc\u30b5\u30a4\u30c8\u30e1\u30c8\u30ea\u30fc\u89e3\u6790\u7528\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u56de\u53ce","author":"LatB Staff","date":"2026\u5e7410\u670830\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30ca\u30ce\u30b5\u30a4\u30ba\u306e\u5c0f\u80de\uff08\u76f4\u5f8430\uff5e100 nm\uff09\u3067\u3042\u308b\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u3092\u3001\u78c1\u6c17\u30d3\u30fc\u30ba\uff08Invitro\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":20129,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-therapy-ts-r-25016\/","url_meta":{"origin":314,"position":4},"title":"\u3010\u7b2c2\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce","author":"LatB Staff","date":"2026\u5e744\u670828\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u306e\u6fc3\u7e2e\u30fb\u56de\u53ce\u306b\u3064\u3044\u3066\u3054\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u5b9f\u969b\u306e\u64cd\u4f5c\u3067\u5f79\u7acb\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u56de\u53ce\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u5c0f\u80de\u4f53\u30b5\u30a4\u30ba","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/03\/251d14a615127ecd8e0dac1beeb32074.jpg?resize=350%2C200&ssl=1","width":350,"height":200},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":314,"position":5},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-8.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/314","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=314"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/314\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2500"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=314"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=314"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=314"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=314"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}