{"id":324,"date":"2016-03-17T00:00:00","date_gmt":"2016-03-17T00:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/"},"modified":"2025-07-02T17:00:51","modified_gmt":"2025-07-02T08:00:51","slug":"pipetting-guide10","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/","title":{"rendered":"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ)"},"content":{"rendered":"<p>\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n<h2>Finnpipette(\u30de\u30cb\u30e5\u30a2\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8)<\/h2>\n<h3>Q:\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6ec5\u83cc\u65b9\u6cd5\u306b\u3064\u3044\u3066\u6559\u3048\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/h3>\n<p>Finnpipette F2(<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4642020?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">4642<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4652000?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">4652<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4662010?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">4662<\/a>\u30b7\u30ea\u30fc\u30b9\u3099)\u304a\u3088\u3072\u3099Digital(<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4500080?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">4500<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4510040?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">4510<\/a>\u30b7\u30ea\u30fc\u30b9\u3099)\u306f\u30aa\u30fc \u30c8\u30af\u30ec\u30fc\u30d5\u3099\u5b8c\u5168\u5bfe\u5fdc\u3066\u3099\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u5168\u4f53\u3092\u5206\u89e3\u305b\u3059\u3099\u306b121\u00b0C 20\u5206\u9593\u306e\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u306b\u304b\u3051\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u4ed6\u306e\u30e2\u30c6\u3099\u30eb\u306f\u3001\u4e0b\u90e8\u30cf\u309a\u30fc\u30c4\u3092\u53d6\u308a\u5916\u3057\u3066\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u306b\u304b\u3051\u3066\u304f\u305f\u3099\u3055\u3044\u3002UV\u7167\u5c04\u3082\u53ef\u80fd\u3066\u3099\u3059\u304b\u3099\u3001\u30cf\u30f3\u30c8\u3099\u30eb\u306e\u8272\u304b\u3099\u9ec4\u8272\u307f\u3092\u304a\u3072\u3099\u3001\u9577\u671f\u9593\u7167\u5c04\u3092\u7d9a\u3051\u308b\u3068\u30d5\u309a\u30e9\u30b9\u30c6\u30a3\u30c3\u30af\u306e\u8868\u9762\u306b\u52a3\u5316\u3092\u751f\u3057\u3099\u308b\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>Q:Finnpipette\u306fUV\u8010\u6027\u304b\u3099\u3042\u308a\u307e\u3059\u304b?<\/h3>\n<p>Finnpipette F\u30b7\u30ea\u30fc\u30b9\u3099\u306fUV\u8010\u6027\u306e\u3042\u308b\u6750\u6599\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002UV\u7167\u5c04\u3092\u7e70\u308a\u8fd4\u3059\u3068\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u8272\u304b\u3099\u9ec4\u8272\u307f\u3092\u5e2f\u3072\u3099\u3066\u304d\u307e\u3059\u3002F1\u306e\u3088\u3046\u306a\u767d\u3044\u8272\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3066\u3099\u306f\u7279\u306b\u76ee\u7acb\u3061\u307e\u3059\u304b\u3099\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u6027\u80fd\u306b\u306f\u5f71\u97ff\u3042\u308a\u307e\u305b\u3093\u3002\u8272\u8abf\u306e\u7d4c\u6642\u5909\u5316\u306f\u3001\u5e02\u8ca9\u3055\u308c\u3066\u3044\u308b\u3068\u3099\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3066\u3099\u3082\u898b\u3089\u308c\u308b\u73fe\u8c61\u3066\u3099\u3059\u3002<\/p>\n<h3>Q:\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306b\u30bf\u3099\u30e1\u30fc\u30b7\u3099\u3092\u4e0e\u3048\u306a\u3044\u5316\u5b66\u85ac\u54c1\u306b\u306f\u3068\u3099\u306e\u3088\u3046\u306a\u3082\u306e\u304b\u3099\u3042\u308a\u307e\u3059\u304b?<\/h3>\n<p>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306b\u4f7f\u308f\u308c\u3066\u3044\u308b\u30d5\u309a\u30e9\u30b9\u30c6\u30a3\u30c3\u30af\u306e\u85ac\u54c1\u8010\u6027\u306e\u8868\u3092\u53c2\u7167\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002\u305f\u305f\u3099\u3057\u3001\u85ac\u54c1\u306e\u6fc3\u5ea6\u3001\u6e29\u5ea6\u3001\u85ac\u54c1\u306b\u63a5\u89e6\u3057\u3066\u3044\u305f\u6642\u9593\u306a\u3068\u3099\u306e\u30d5\u30a1\u30af\u30bf\u3082\u5f71\u97ff\u3057\u307e\u3059\u3002<\/p>\n<h3>Q:Finnpipette\u306f\u8efd\u304f\u3066\u64cd\u4f5c\u3057\u3084\u3059\u3044\u3068\u805e\u3044\u3066\u3044\u307e\u3059\u304b\u3099\u3001\u8efd\u91cf\u305f\u3099\u3068\u58ca\u308c\u3084\u3059\u304f\u306f\u3042\u308a\u307e\u305b\u3093\u304b?<\/h3>\n<p>Finnpipette\u306e\u958b\u767a\u8a2d\u8a08\u306b\u304a\u3044\u3066\u306f\u5e38\u306b\u512a\u308c\u305f\u6027\u80fd\u3068\u8010\u4e45\u6027\u3092\u3082\u3064\u6750\u6599\u3092\u9078\u3093\u3066\u3099\u3044\u307e\u3059\u3002\u8fd1\u5e74\u3066\u3099\u306f\u3088\u308a\u4e08\u592b\u3066\u3099\u8010\u6027\u306b\u512a\u308c\u305f\u30d5\u309a\u30e9\u30b9\u30c6\u30a3\u30c3\u30af\u304b\u3099\u958b\u767a\u3055\u308c\u3066\u3044\u307e\u3059\u3002Finnpipette\u306f\u3001\u901a\u5e383\u5e74\u9593\u3001\u8cfc\u5165\u6642\u306bWeb\u767b\u9332\u3057\u3066\u3044\u305f\u305f\u3099\u304f\u30685\u5e74\u9593(\u30de\u30cb\u30e5\u30a2\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5834\u5408)\u306e\u4fdd\u8a3c\u671f\u9593\u304b\u3099\u3042\u308a\u3001\u5b89\u5fc3\u3057\u3066\u304a\u4f7f\u3044\u3044\u305f\u305f\u3099\u3051\u307e\u3059\u3002<\/p>\n<h2>Finnpipette F1(<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4641080N?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener\">4641<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4651080N?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener\">4651<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/4661010N?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener\">4661<\/a>\u30b7\u30ea\u30fc\u30b9\u3099)<\/h2>\n<h3>Q:F1\u306e\u30af\u30ea\u30fc\u30cb\u30f3\u30af\u3099\u65b9\u6cd5\u3092\u6559\u3048\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/h3>\n<p>\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u306b\u304b\u3051\u3089\u308c\u308b\u30cf\u309a\u30fc\u30c4\u306f\u5bb9\u91cf\u30e2\u30c6\u3099\u30eb\u306b\u3088\u308a\u7570\u306a\u308a\u307e\u3059\u306e\u3066\u3099\u3001\u53d6\u6271\u8aac\u660e\u66f8\u3066\u3099\u78ba\u8a8d\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002\u307e\u305f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3066\u3099\u5168\u4f53\u3092\u30af\u30ea\u30fc\u30cb\u30f3\u30af\u3099\u3059\u308b\u969b\u306f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u6d78\u3057\u305f\u30b3\u30c3\u30c8\u30f3\u3092\u56fa\u304f\u7d5e\u3063\u305f\u3082\u306e\u3066\u3099\u62ed\u3044\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h2>Finnpipette Novus(\u96fb\u52d5\u30d2\u309a\u30d8\u309a\u30c3\u30c8<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/46200000?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener\">4620<\/a>\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/46300000?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener\">4630<\/a>\u30b7\u30ea\u30fc\u30b9\u3099)<\/h2>\n<h3>Q:\u30cf\u3099\u30c3\u30c6\u30ea\u306e\u5bff\u547d\u306f\u3068\u3099\u306e\u304f\u3089\u3044\u3066\u3099\u3059\u304b?<\/h3>\n<p>\u7d043\u5e74\u3066\u3099\u3059\u3002\u4f7f\u7528\u983b\u5ea6\u306b\u3088\u3063\u3066\u3082\u7570\u306a\u308a\u307e\u3059\u3002<\/p>\n<h3>Q:\u30cf\u3099\u30c3\u30c6\u30ea\u3092\u4ea4\u63db\u3057\u305f\u3089\u300cERROR15\u300d\u3068\u8868\u793a\u3055\u308c\u307e\u3057\u305f\u3002 \u3068\u3099\u3093\u306a\u610f\u5473\u3066\u3099\u3057\u3087\u3046\u304b?<\/h3>\n<p>\u30cf\u3099\u30c3\u30c6\u30ea\u304b\u3099\u4e00\u5ea6\u5916\u3055\u308c\u305f\u3053\u3068\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059\u3002\u7570\u5e38\u3066\u3099\u306f\u3042\u308a\u307e\u305b\u3093\u306e\u3066\u3099\u753b\u9762\u53f3\u4e0b\u306eOK\u3092\u62bc\u3057\u3066\u30ea\u30bb\u30c3\u30c8\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h3>Q:\u30d5\u30eb\u5145\u96fb\u5f8c\u3001\u3068\u3099\u306e\u304f\u3089\u3044\u30d2\u309a\u30d8\u309a\u30c3\u30c6\u30a3\u30f3\u30af\u3099\u3066\u3099\u304d\u307e\u3059\u304b?<\/h3>\n<p>\u901a\u5e38\u7d044000\u56de\u4f7f\u7528\u3066\u3099\u304d\u307e\u3059\u3002\u5927\u5bb9\u91cf(10ml\u306a\u3068\u3099)\u3084\u30de\u30eb\u30c1\u30c1\u30e3\u30f3\u30cd\u30eb\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306f\u82e5\u5e72\u6d88\u8017\u304b\u3099\u65e9\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n<h3>Q:\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u6ec5\u83cc\u306f\u3066\u3099\u304d\u307e\u3059\u304b?<\/h3>\n<p>\u30c1\u30c3\u30d5\u309a\u30b3\u30fc\u30f3\u306a\u3068\u3099\u4e0b\u90e8\u30cf\u309a\u30fc\u30c4\u3092\u53d6\u308a\u5916\u3057\u3066121\u00b0C\u3066\u309920\u5206\u9593\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u306b\u304b\u3051\u308b\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002\u53d6\u5916\u3057\u306f\u5fc5\u3059\u3099SERVICE\u30e2\u30fc\u30c8\u3099 (OPTIONS&gt;SERVICE)\u3066\u3099\u884c\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002\u8a73\u7d30\u306f\u53d6\u6271\u8aac\u660e\u66f8\u3092\u53c2\u7167\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002\u30cf\u30f3\u30c8\u3099\u30eb(\u672c\u4f53)\u90e8\u5206\u306f\u96fb\u5b50\u90e8\u54c1\u3092\u542b\u3080\u305f\u3081\u3001\u30aa\u30fc\u30c8\u30af\u30ec\u30fc\u30d5\u3099\u3066\u3099\u304d\u307e\u305b\u3093\u3002<\/p>\n<h3>Q:\u5bb9\u91cf\u8abf\u6574\u3092\u3057\u305f\u3044\u306e\u3066\u3099\u3059\u304b\u3099&#8230;<\/h3>\n<p>CALIBRATE\u30e2\u30fc\u30c8\u3099(OPTIONS&gt;CALIBRATE)\u3066\u3099\u884c\u3046\u3053\u3068\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u3002\u8a73\u7d30\u306f\u300c\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u300d\u306e\u9805\u3084\u53d6\u6271\u8aac\u660e\u66f8\u3092\u53c2\u7167\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h2>\u30c1\u30c3\u30d5\u309a<\/h2>\n<h3>Q:Finntip\u4ee5\u5916\u306e\u30c1\u30c3\u30d5\u309a\u3092\u4f7f\u7528\u3066\u3099\u304d\u307e\u3059\u304b?<\/h3>\n<p>\u57fa\u672c\u7684\u306b\u7d14\u6b63\u30d5\u30a3\u30f3\u30c1\u30c3\u30d5\u309a\u306e\u4f7f\u7528\u3092\u304a\u3059\u3059\u3081\u3057\u307e\u3059\u3002\u4ed6\u306e\u30d5\u3099\u30e9\u30f3\u30c8\u3099\u306e\u30c1\u30c3\u30d5\u309a\u3082\u4f7f\u7528\u53ef\u80fd\u3066\u3099\u3059\u304b\u3099\u3001\u30c1\u30c3\u30d5\u309a\u30b3\u30fc\u30f3\u3078\u306e\u9069\u5408\u6027\u304b\u3099\u539f\u56e0\u3066\u3099\u4e0b\u8a18\u306e\u3088\u3046\u306a\u554f\u984c\u3092\u751f\u3057\u3099\u308b\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u7cbe\u5ea6\u304b\u3099\u4f4e\u4e0b\u3059\u308b<\/li>\n<li>\u30c1\u30c3\u30d5\u309a\u3092\u3057\u3063\u304b\u308a\u5bc6\u7740\u3055\u305b\u3088\u3046\u3068\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3092\u30c1\u30c3\u30d5\u309a\u306b\u5f37\u304f\u62bc\u3057\u8fbc\u3093\u305f\u3099\u308a\u3001\u30e9\u30c3\u30af\u4e0a\u306e\u30c1\u30c3\u30d5\u309a\u306b\u305f\u305f\u304d\u3064\u3051\u305f\u308a\u3057\u3066\u3001\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u640d\u50b7\u3084\u6545\u969c\u306e\u539f\u56e0\u306b\u306a\u308b<\/li>\n<li>\u30c1\u30c3\u30d5\u309a\u30b3\u30fc\u30f3\u3078\u306e\u88c5\u7740\u304b\u3099\u6d45\u304f\u3001\u30c1\u30c3\u30d5\u309a\u30a4\u30b7\u3099\u30a7\u30af\u30bf\u304b\u3099\u5c4a\u304d\u306b\u304f\u3044\u305f\u3081\u3001\u30c1\u30c3\u30d5\u309a\u304b\u3099\u3046\u307e\u304f\u53d6\u308a\u5916\u305b\u306a\u3044<\/li>\n<\/ul>\n<h2>\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3068\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30b5\u30fc\u30d2\u3099\u30b9<\/h2>\n<h3>Q:\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306f\u3068\u3099\u306e\u304f\u3089\u3044\u306e\u983b\u5ea6\u3066\u3099\u884c\u3063\u305f\u3089\u3044\u3044\u3066\u3099\u3057\u3087\u3046\u304b?<\/h3>\n<p>\u4f7f\u7528\u3059\u308b\u6db2\u4f53\u3084\u8981\u6c42\u3055\u308c\u308b\u7cbe\u5ea6\u306b\u3088\u3063\u3066\u3082\u7570\u306a\u308a\u307e\u3059\u3002\u901a\u5e38\u3001\u6c34\u6eb6\u6db2\u3066\u3099\u6bce\u65e5\u4f7f\u7528\u3059\u308b\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5834\u5408\u30013 \u30f6\u6708\u306b1\u5ea6\u306f\u5206\u89e3\u3057\u3066\u5185\u90e8\u306e\u6383\u9664\u3092\u884c\u3044\u3001\u691c\u5b9a\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u8a73\u7d30\u306f\u53d6\u6271\u8aac\u660e\u66f8\u3092\u3053\u3099\u53c2\u7167\u304f\u305f\u3099\u3055\u3044\u3002\u307e\u305f\u3001O-\u30ea\u30f3\u30af\u3099\u7b49\u306e\u6d88\u8017\u90e8\u54c1\u306f\u5b9a\u671f\u7684(\u5e741\u56de\u7a0b\u5ea6)\u306b\u4ea4\u63db\u3059\u308b\u5fc5\u8981\u304b\u3099\u3042\u308a\u307e\u3059\u3002\u5f0a\u793e\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30b5\u30fc\u30d2\u3099\u30b9\u3066\u3099\u306f\u3001\u5b9a\u671f\u70b9\u691c\u306b\u9069\u3057\u305f\u30cf\u309a\u30c3\u30b1\u30fc\u30b7\u3099(\u70b9\u691c\u3068\u30af\u30ea\u30fc\u30cb\u30f3\u30af\u3099\u3001\u6d88\u8017\u90e8\u54c1\u306e\u4ea4\u63db\u3001\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3057\u3001Calibration Report(\u691c\u5b9a\u30c6\u3099\u30fc\u30bf\u30b7\u30fc\u30c8\u30fb\u82f1\u6587)\u3092\u6dfb\u4ed8\u3057\u3066\u304a\u8fd4\u3057\u3057\u307e\u3059)\u3092\u30ea\u30fc\u30b9\u3099\u30ca\u30d5\u3099\u30eb\u306a\u6599\u91d1\u3066\u3099\u63d0\u4f9b\u3057\u3066\u304a\u308a\u307e\u3059\u3002<\/p>\n<h3>Q:\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30b5\u30fc\u30d2\u3099\u30b9(\u70b9\u691c\u30fb\u4fee\u7406)\u3092\u4f9d\u983c\u3057\u305f\u3044\u306e\u3066\u3099\u3059\u304b\u3099&#8230;<\/h3>\n<p>\u300c\u30b5\u30fc\u30d2\u3099\u30b9\u4f9d\u983c\u66f8\u300d\u3068\u300c\u6c5a\u67d3\u9664\u53bb\u8a3c\u660e\u66f8\u300d\u306b\u8a18\u5165\u3057\u3001\u30b5\u30fc\u30d2\u3099\u30b9\u3092\u4f9d\u983c\u3059\u308b\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306b\u6dfb\u4ed8\u3092\u304a\u9858\u3044\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n<ul>\n<li>\u300c\u30b5\u30fc\u30d2\u3099\u30b9\u4f9d\u983c\u66f8\u300d\u3068\u300c\u6c5a\u67d3\u9664\u53bb\u8a3c\u660e\u66f8\u300d\u306f\u30bb\u30c3\u30c8\u306b\u306a\u3063\u3066\u3044\u3066\u3001<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u5f0a\u793e\u30a6\u30a7\u30d6\u30b5\u30a4\u30c8<\/a>\u304b\u3089\u30bf\u3099\u30a6\u30f3\u30ed\u30fc\u30c8\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/li>\n<li>\u300c\u30b5\u30fc\u30d2\u3099\u30b9\u4f9d\u983c\u66f8\u300d\u306f\u4ee5\u4e0b\u306e\u4e2d\u304b\u3089\u3053\u3099\u4f9d\u983c\u5185\u5bb9\u306b\u3042\u308f\u305b\u3066\u304a\u9078\u3072\u3099\u304f\u305f\u3099\u3055\u3044\u3002\n<ul>\n<li>ISO\/IEC 17025\u306b\u57fa\u3064\u3099\u304f\u6821\u6b63\u30b5\u30fc\u30d2\u3099\u30b9\u4f9d\u983c\u66f8<\/li>\n<li>\u30d5\u30a3\u30f3\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30b5\u30fc\u30d2\u3099\u30b9\u4f9d\u983c\u66f8<\/li>\n<li>\u30cf\u3099\u30ea\u30c6\u3099\u30fc\u30b7\u30e7\u30f3\u30b5\u30db\u309a\u30fc\u30c8\u7533\u8fbc\u66f8<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u30b5\u30fc\u30d2\u3099\u30b9\u4f9d\u983c\u66f8\u5f0a\u793e\u3066\u3099\u306f\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u8f38\u9001\u7528\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30b5\u30fc\u30d2\u3099\u30b9\u30cf\u3099\u30c3\u30af\u3099\u3092\u3053\u3099\u7528\u610f\u3057\u3066\u304a\u308a\u307e\u3059\u3002\u304a\u6c17\u8efd\u306b\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u30b5\u30fc\u30d2\u3099\u30b9\u30bb\u30f3\u30bf\u30fc\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u4e0b\u3055\u3044\u3002<\/p>\n<h3>Q:ISO8655\u306b\u5f93\u3063\u305f\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u304b\u3099\u3066\u3099\u304d\u307e\u3059\u304b?<\/h3>\n<p>\u5f0a\u793e\u306fISO\/IEC17025\u3092\u53d6\u5f97\u3057\u3066\u304a\u308a\u3001\u305d\u306e\u624b\u9806\u306fISO8655\u306b\u6e96\u62e0\u3057\u3066\u304a\u308a\u307e\u3059\u306e\u3066\u3099\u53ef\u80fd\u3066\u3099\u3059\u3002<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-iso.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">ISO\u6821\u6b63\u30b5\u30fc\u30d2\u3099\u30b9<\/a>\u306f\u5c02\u7528\u306e\u30b5\u30fc\u30d2\u3099\u30b9\u4f9d\u983c\u66f8\u3092\u3053\u3099\u5229\u7528\u4e0b\u3055\u3044\u3002 \u4f9d\u983c\u66f8\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-iso.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u5f0a\u793e\u30db\u30fc\u30e0\u30d8\u309a\u30fc\u30b7\u3099<\/a>\u304b\u3089\u30bf\u3099\u30a6\u30f3\u30ed\u30fc\u30c8\u3099\u3066\u3099\u304d\u307e\u3059\u3002<\/p>\n<h3>Q:\u54c1\u8cea\u30b7\u30b9\u30c6\u30e0\u3092\u5c0e\u5165\u3057\u3066\u3044\u307e\u3059\u3002\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u4fee\u7406\u3084\u70b9\u691c\u3092\u4f9d\u983c\u3057\u305f\u5834\u5408\u3001\u54c1\u8cea\u8a3c\u660e\u66f8\u306e\u767a\u884c\u306f\u53ef\u80fd\u3066\u3099\u3059\u304b?<\/h3>\n<p><a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-iso.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30cf\u3099\u30ea\u30c6\u3099\u30fc\u30b7\u30e7\u30f3\u30b5\u30db\u309a\u30fc\u30c8<\/a>\u306e\u30b5\u30fc\u30d2\u3099\u30b9\u3092\u304a\u7533\u8fbc\u307f\u304f\u305f\u3099\u3055\u3044\u3002\u30cf\u3099\u30ea\u30c6\u3099\u30fc\u30b7\u30e7\u30f3\u30b5\u30db\u309a\u30fc\u30c8\u306f\u3001GLP\u3001GMP\u306a\u3068\u3099\u54c1\u8cea\u4fdd\u8a3c\u30b7\u30b9\u30c6\u30e0\u3078\u306e\u5bfe\u5fdc\u3092\u652f\u63f4\u3059\u308b\u30b5\u30fc\u30d2\u3099\u30b9\u3066\u3099\u3001ISO\/IEC17025\u306b\u57fa\u3064\u3099\u304f\u6821\u6b63\u30b5\u30fc\u30d2\u3099\u30b9\u3092\u5b9f\u65bd\u3057\u3066\u304a\u308a\u3001\u300cISO\u6821\u6b63\u8a3c\u660e\u66f8\u300d\u3092\u767a\u884c\u3057\u307e\u3059\u3002\u5e74\u9593\u5951\u7d04\u30b3\u30fc\u30b9(Finnpipette10\u672c\u4ee5\u4e0a)\u3068\u30b9\u30db\u309a\u30c3\u30c8\u30b5\u30fc\u30d2\u3099\u30b9(10\u672c\u672a\u6e80)\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<h2>\u305d\u306e\u4ed6<\/h2>\n<h3>Q:\u7a7a\u6c17\u7f6e\u63db\u65b9\u5f0f\u3068\u5f37\u5236\u7f6e\u63db\u65b9\u5f0f\u306e\u9055\u3044\u306f\u4f55\u3066\u3099\u3059\u304b?<\/h3>\n<p>\u3044\u3059\u3099\u308c\u306e\u30bf\u30a4\u30d5\u309a\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3082\u3001\u30d2\u309a\u30b9\u30c8\u30f3\u304b\u3099\u30b7\u30ea\u30f3\u30bf\u3099\u307e\u305f\u306f\u30ad\u30e3\u30d2\u309a\u30e9\u30ea\u5185\u3092\u52d5\u304f\u69cb\u9020\u3066\u3099\u3059\u3002\u7a7a\u6c17\u7f6e\u63db\u65b9\u5f0f\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u5185\u3066\u3099\u306f\u3001\u4e00\u5b9a\u306e\u91cf\u306e\u7a7a\u6c17\u304b\u3099\u30d2\u309a\u30b9\u30c8\u30f3\u3068\u6db2\u4f53\u306e\u9593\u306b\u6b8b\u308a\u307e\u3059\u3002\u5f37\u5236\u7f6e\u63db\u65b9\u5f0f\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3066\u3099\u306f\u3001\u30d2\u309a\u30b9\u30c8\u30f3\u304b\u3099\u76f4\u63a5\u6db2\u4f53\u306b\u63a5\u89e6\u3057\u307e\u3059\u3002\u7a7a\u6c17\u304b\u3099\u30c1\u30c3\u30d5\u309a\u306e\u4e2d\u306b\u5165\u3089\u3059\u3099\u3001\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u9632\u6b62\u306b\u52b9\u679c\u7684\u3066\u3099\u3059\u3002\u7a7a\u6c17\u7f6e\u63db\u65b9\u5f0f\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306f\u6c34\u6eb6\u6db2\u306e\u5206\u6ce8\u306b\u4e00\u822c\u7684\u306b\u4f7f\u308f\u308c\u307e\u3059\u3002\u5f37\u5236\u7f6e\u63db\u65b9\u5f0f\u306f\u7c98\u6027\u306e\u9ad8\u3044\u6db2\u4f53\u3084\u63ee\u767a\u6027\u306e\u6db2\u4f53\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<h3>Q:\u7c98\u6027\u306e\u9ad8\u3044\u6db2\u4f53\u306e\u5206\u6ce8\u306f\u3068\u3099\u3046\u3057\u305f\u3089\u3044\u3044\u3066\u3099\u3059\u304b?<\/h3>\n<p>\u7a7a\u6c17\u7f6e\u63db\u65b9\u5f0f\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3066\u3099\u3001\u30b9\u30bf\u30f3\u30bf\u3099\u30fc\u30c8\u3099\u307e\u305f\u306f\u30ef\u30a4\u30c8\u3099\u30c1\u30c3\u30d5\u309a\u3092\u4f7f\u7528\u3057\u3001\u30ea\u30cf\u3099\u30fc\u30b9\u6cd5\u3066\u3099\u3086\u3063\u304f\u308a\u64cd\u4f5c\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u6b63\u78ba\u306b\u5206\u6ce8\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u305d\u306e\u6db2\u4f53\u3092\u4f7f\u3063\u3066\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002\u6c34\u4ee5\u5916\u306e\u6db2\u4f53\u3066\u3099\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3046\u3068\u304d\u306f\u3001\u305d\u306e\u6db2\u4f53\u306e\u5bc6\u5ea6\u3066\u3099\u691c\u5b9a\u7d50\u679c\u3092\u88dc\u6b63\u3057\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h3>Q:\u63ee\u767a\u3057\u3084\u3059\u3044\u6db2\u4f53\u3092\u5206\u6ce8\u3059\u308b\u3068\u304d\u3001\u6db2\u4f53\u304b\u3099\u30c1\u30c3\u30d5\u309a\u304b\u3089\u5782\u308c\u843d\u3061\u308b\u306e\u3092\u9632\u304f\u3099\u306b\u306f\u3068\u3099\u3046\u3057\u305f\u3089\u3044\u3044\u3066\u3099\u3059\u304b?<\/h3>\n<p>\u7a7a\u6c17\u7f6e\u63db\u65b9\u5f0f\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u30c1\u30c3\u30d5\u309a\u306e\u5148\u3092\u6db2\u4f53\u306b\u6d78\u3057\u305f\u307e\u307e\u6570\u56de\u5438\u6392\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30c1\u30c3\u30d5\u309a\u5185\u90e8\u306e\u7a7a\u6c17\u304b\u3099\u63ee\u767a\u6027\u7269\u8cea\u306e\u84b8\u6c17\u3066\u3099\u98fd\u548c\u72b6\u614b\u306b\u306a\u308a\u3001\u6db2\u305f\u3099\u308c\u3092\u6291\u5236\u3057\u307e\u3059\u3002\u64cd\u4f5c\u306f\u3066\u3099\u304d\u308b\u305f\u3099\u3051\u3059\u306f\u3099\u3084\u304f\u884c\u3063\u3066\u304f\u305f\u3099\u3055\u3044\u3002<\/p>\n<h3>Q:\u6e29\u304b\u3044\u6db2\u4f53\u3084\u51b7\u305f\u3044\u6db2\u4f53\u3092\u5206\u6ce8\u3059\u308b\u3068\u7cbe\u5ea6\u306b\u3068\u3099\u306e\u3088\u3046\u306a\u5f71\u97ff\u304b\u3099\u3042\u308a\u307e\u3059\u304b?<\/h3>\n<p>\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306f\u901a\u5e3820-25\u00b0C\u306e\u84b8\u7559\u6c34\u307e\u305f\u306f\u30a4\u30aa\u30f3\u4ea4\u63db\u6c34\u3092\u7528\u3044\u3066\u91cd\u91cf\u6cd5\u3066\u3099\u30ad\u30e3\u30ea\u30d5\u3099\u30ec\u30fc\u30b7\u30e7\u30f3\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u540c\u3057\u3099\u5bb9\u91cf\u3066\u3099\u3082\u3001\u6e29\u304b\u3044\u6db2\u4f53\u306e\u5834\u5408\u8cea\u91cf\u304b\u3099\u5c0f\u3055\u304f\u3001\u51b7\u305f\u3044\u6db2\u4f53\u306e\u5834\u5408\u8cea\u91cf\u304b\u3099\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u7a7a\u6c17\u7f6e\u63db\u65b9\u5f0f\u306e\u30d2\u309a\u30d8\u309a\u30c3\u30c8\u306e\u5834\u5408\u3001\u30d2\u309a\u30b9\u30c8\u30f3\u3068\u6db2\u4f53\u306e\u9593\u306b\u3042\u308b\u7a7a\u6c17\u306e\u5bb9\u7a4d\u304b\u3099\u6e29\u5ea6\u5909\u5316\u306b\u3088\u3063\u3066\u81a8\u5f35\u307e\u305f\u306f\u53ce\u7e2e\u3059\u308b\u305f\u3081\u3001\u5206\u6ce8\u91cf\u304b\u3099\u4e0d\u6b63\u78ba\u306b\u306a\u3063\u305f\u308a\u3001\u306f\u3099\u3089\u3064\u3044\u305f\u308a\u3059\u308b\u3053\u3068\u304b\u3099\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>GLP\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/h3>\n<p>\u5f53\u793e\u306e\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c4\u30fc\u30eb\u306e\u9078\u629e\u3084\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u9069\u3057\u305f\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30c6\u30af\u30cb\u30c3\u30af\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u308b\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30b0\u30ac\u30a4\u30c9<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/glp-guide-form.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n<h3>\u3010\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u5c55\u958b\u4e2d\u3011\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u53ef\u80fd\u3067\u3059\uff01<\/h3>\n<p>\u666e\u6bb5\u306e\u5b9f\u9a13\u306b\u6b20\u304b\u305b\u306a\u3044\u30d4\u30da\u30c3\u30c8\u306e\u6821\u6b63\u306b\u3064\u3044\u3066\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u60a9\u307f\u3092\u304a\u6301\u3061\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n<ul>\n<li>\u300c\u5404\u30e1\u30fc\u30ab\u30fc\u3078\u306e\u500b\u5225\u4f9d\u983c\u304c\u9762\u5012\u300d<\/li>\n<li>\u300c\u4fa1\u683c\u3001\u7d0d\u671f\u304c\u30d0\u30e9\u30d0\u30e9\u3067\u7ba1\u7406\u304c\u5927\u5909\u300d<\/li>\n<li>\u300c\u30e1\u30fc\u30ab\u30fc\u3054\u3068\u3067\u57fa\u6e96\u3084\u66f8\u985e\u304c\u7570\u306a\u308b\u305f\u3081\u5185\u5bb9\u3092\u628a\u63e1\u3067\u304d\u306a\u3044\u300d<\/li>\n<\/ul>\n<p>Thermo Fisher Scientific\u3067\u306f\u3001<strong>\u3042\u3089\u3086\u308b\u30e1\u30fc\u30ab\u30fc\u306e\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u304c\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/strong><\/p>\n<p>\u307e\u305f\u3001<strong>ISO,GLP,GMP\u306a\u3069\u54c1\u8cea\u4fdd\u8a3c\u3092\u5fc5\u8981\u3068\u3055\u308c\u308b\u304a\u5ba2\u69d8\u306b\u5f53\u793e\u306e\u8cea\u306e\u9ad8\u3044\u30d4\u30da\u30c3\u30c8\u6821\u6b63\u30b5\u30fc\u30d3\u30b9\u3092\u63d0\u4f9b<\/strong>\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<p>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306b\u3064\u3044\u3066\u3001\u300c<strong>\u8a71\u3092\u805e\u3044\u3066\u307f\u305f\u3044<\/strong>\u300d\u3001\u300c<strong>\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u30ab\u30bf\u30ed\u30b0\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u305f\u3044<\/strong>\u300d<\/p>\n<p>\u3068\u304a\u8003\u3048\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u306e\u30dc\u30bf\u30f3\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services\/pipette-inquiry.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u304a\u554f\u3044\u5408\u308f\u305b\u30fb\u30ab\u30bf\u30ed\u30b0\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u5e0c\u671b\u3059\u308b<\/a><\/p>\n<p>\u307e\u305f\u3001\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u4e0b\u8a18\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff01<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/products-and-services\/services\/pipette-services.html?CID=lpd_lpe_lhs_r04_jp_cp0000_pjt0000_lpd00000_0so_blg_op_awa_oc_s00_lhc10_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30d4\u30da\u30c3\u30c8\u30b5\u30fc\u30d3\u30b9\u306e\u8a73\u7d30\u3092\u307f\u308b<\/a><\/p>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u76ee\u7684\u304a\u3088\u3073\u305d\u306e\u624b\u7d9a\u304d\u4e0a\u3067\u306e\u4f7f\u7528\u306f\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n","protected":false},"author":988,"featured_media":2514,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[41],"division":[],"class_list":["post-324","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mol-bio","tag-pipetting","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ) - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ)\" \/>\n<meta property=\"og:description\" content=\"\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2016-03-17T00:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-07-02T08:00:51+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"12\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"headline\":\"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ)\",\"datePublished\":\"2016-03-17T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:00:51+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/\"},\"wordCount\":81,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-9.jpg\",\"keywords\":[\"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/\",\"name\":\"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ) - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-9.jpg\",\"datePublished\":\"2016-03-17T00:00:00+00:00\",\"dateModified\":\"2025-07-02T08:00:51+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-9.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/pipetting-guide-title-9.jpg\",\"width\":1200,\"height\":630,\"caption\":\"pipetting-guide-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/pipetting-guide10\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ)\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/201e6a5abb838fa34e8ff0174b015d36\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ) - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ)","og_description":"\u666e\u6bb5\u3001\u304a\u5ba2\u69d8\u304b\u3089\u3044\u305f\u3060\u304f\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u306e\u3054\u8cea\u554f\u306b\u3064\u3044\u3066\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3068\u305d\u306e\u89e3\u6c7a\u65b9\u6cd5\u3092\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u3067\u304a\u56f0\u308a\u306e\u969b\u306f\u305c\u3072\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2016-03-17T00:00:00+00:00","article_modified_time":"2025-07-02T08:00:51+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9.jpg","type":"image\/jpeg"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"12\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"headline":"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ)","datePublished":"2016-03-17T00:00:00+00:00","dateModified":"2025-07-02T08:00:51+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/"},"wordCount":81,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9.jpg","keywords":["\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/","name":"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ) - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9.jpg","datePublished":"2016-03-17T00:00:00+00:00","dateModified":"2025-07-02T08:00:51+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9.jpg","width":1200,"height":630,"caption":"pipetting-guide-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/pipetting-guide10\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3010\u307e\u3068\u3081\u3011\u30d5\u30a3\u30f3\u30d4\u30da\u30c3\u30c8\u306b\u3064\u3044\u3066\u3088\u304f\u3042\u308b\u8cea\u554f\u3068\u56de\u7b54\u3092\u307e\u3068\u3081\u3066\u307f\u305f(Finnpipette FAQ)"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/201e6a5abb838fa34e8ff0174b015d36","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":41,"label":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9-1024x538.jpg",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":540,"filter":"raw","meta":[],"cat_ID":156,"category_count":540,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":41,"name":"\u30d4\u30da\u30c3\u30c6\u30a3\u30f3\u30af\u3099","slug":"pipetting","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":16,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":25540,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cloning-cell-separation-bid-ts-mbr-26023\/","url_meta":{"origin":324,"position":0},"title":"\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b92\uff5e\u5b9f\u969b\u306b\u57f9\u990a\u3057\u3066\u307f\u3088\u3046","author":"LatB Staff","date":"2026\u5e748\u670826\u65e5","format":false,"excerpt":"\u30d6\u30ed\u30b0\u300c\u5927\u8178\u83cc\u306e\u98fc\u3044\u65b9\uff5e\u5b9f\u9a13\u306b\u5fc5\u8981\u306a\u8a2d\u5099\u3092\u305d\u308d\u3048\u3088\u3046\u300d\u3067\u306f\u3001\u30af\u30ed\u30fc\u30cb\u30f3\u30b0\u3084\u7d44\u307f\u63db\u3048\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u306e\u7528\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/08\/cloning-cell-separation-bid-ts-mbr-26023_eyecatch.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":324,"position":1},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":23765,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065\/","url_meta":{"origin":324,"position":2},"title":"\u3010\u3084\u3063\u3066\u307f\u305f\u3011\u51dd\u96c6\u3057\u3084\u3059\u3044\u7d30\u80de\u3092\u3042\u306e\u624b\u3053\u306e\u624b\u3067\u307b\u3050\u3057\u3066\u307f\u305f","author":"LatB Staff","date":"2025\u5e7411\u67084\u65e5","format":false,"excerpt":"\u7d30\u80de\u57f9\u990a\u5b9f\u9a13\u306b\u304a\u3044\u3066\u3001\u7d30\u80de\u6570\u3084\u751f\u7d30\u80de\u7387\u30fb\u6b7b\u7d30\u80de\u7387\u306e\u6e2c\u5b9a\uff08\u3044\u308f\u3086\u308b\u30bb\u30eb\u30ab\u30a6\u30f3\u30c8\uff09\u306f\u91cd\u8981\u306a\u30b9\u30c6\u30c3\u30d7\u3067\u3059\u3002\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":23864,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-expression-cloning-bid-ts-mbr-25070\/","url_meta":{"origin":324,"position":3},"title":"\u521d\u5fc3\u8005\u3067\u3082\u5b89\u5fc3\uff01\u7c21\u5358\u306b\u3067\u304d\u308b\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u306e\u4f5c\u308a\u65b9\uff1a\u4eba\u5de5\u907a\u4f1d\u5b50\u5408\u6210\u30b5\u30fc\u30d3\u30b9\u306e\u5229\u7528\u6cd5","author":"LatB Staff","date":"2025\u5e7411\u670813\u65e5","format":false,"excerpt":"\u30bf\u30f3\u30d1\u30af\u8cea\u767a\u73fe\u5b9f\u9a13\u306b\u306f\u767a\u73fe\u30d9\u30af\u30bf\u30fc\u304c\u6b20\u304b\u305b\u307e\u305b\u3093\u304c\u3001\u4e00\u304b\u3089\u4f5c\u308b\u3068\u306a\u308b\u3068\u3001\u304b\u306a\u308a\u306e\u624b\u9593\u3068\u7d4c\u9a13\u304c\u5fc5\u8981\u3067\u3059\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/10\/protein-expression-cloning-bid-ts-mbr-25070_eyecatch.png?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24152,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-protein-expression-bid-ts-mbr-25074\/","url_meta":{"origin":324,"position":4},"title":"\u30bf\u30f3\u30d1\u30af\u7523\u751f\u3084\u30a6\u30a4\u30eb\u30b9\u7523\u751f\u3092\u76ee\u7684\u3068\u3057\u305f\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u5c0e\u5165\u306e\u7b2c\u4e00\u6b69\uff1a\u7d30\u80de\u682a\u306e\u7d99\u4ee3\u3068\u51cd\u7d50\u4fdd\u5b58\u7de8","author":"LatB Staff","date":"2025\u5e7412\u67083\u65e5","format":false,"excerpt":"\u9ad8\u5bc6\u5ea6\u7d30\u80de\u57f9\u990a\u30b7\u30b9\u30c6\u30e0\u3067\u306f\u3001\u5c02\u7528\u306e\u6d6e\u904a\u7d30\u80de\u682a\u3092\u7528\u3044\u3066\u6c7a\u3081\u3089\u308c\u305f\u624b\u9806\u3067\u57f9\u990a\u3057\u307e\u3059\u3002\u5b89\u5b9a\u7684\u306b\u904b\u7528\u3059\u308b\u305f\u3081\u2026","rel":"","context":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","block_context":{"text":"\u7d30\u80de\u57f9\u990a\u30fb\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/cell\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-protein-expression-bid-ts-mbr-25074_eycatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":24695,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/environmental-analysis-laboratory-lpd-26008\/","url_meta":{"origin":324,"position":5},"title":"Orion Pro Star pH\uff0fISE\u30e1\u30fc\u30bf\u30fc\u3067\u5b9f\u73fe\u3059\u308b\u30a2\u30f3\u30e2\u30cb\u30a2\u30a4\u30aa\u30f3\u306e\u8fc5\u901f\u30fb\u9ad8\u7cbe\u5ea6\u6e2c\u5b9a\u5165\u9580","author":"LatB Staff","date":"2026\u5e742\u670818\u65e5","format":false,"excerpt":"\u6c34\u8cea\u30fb\u5ec3\u6c34\u51e6\u7406\u306e\u73fe\u5834\u3067\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6fc3\u5ea6\u306e\u7ba1\u7406\u306f\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u6b63\u5e38\u306b\u4fdd\u3061\u3001\u6cd5\u898f\u5236\u306b\u9069\u5408\u3059\u308b\u305f\u3081\u306b\u6b20\u304b\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/environmental-analysis-laboratory-lpd-26008_eyecatch_.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/pipetting-guide-title-9.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=324"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/324\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2514"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=324"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}