{"id":325,"date":"2020-04-01T00:00:00","date_gmt":"2020-03-31T15:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/"},"modified":"2025-08-12T17:27:48","modified_gmt":"2025-08-12T08:27:48","slug":"chemiluminescent-westernblotting-guide","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/","title":{"rendered":"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9"},"content":{"rendered":"<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\uff08Western Blotting\uff09\u306f\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u540c\u5b9a\u3084\u76f8\u5bfe\u5b9a\u91cf\u89e3\u6790\u3092\u76ee\u7684\u3068\u3057\u3066\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u308b\u5b9f\u9a13\u624b\u6cd5\u3067\u3059\u3002\u901a\u5e38\u3001\u30cb\u30c8\u30ed\u30bb\u30eb\u30fc\u30b9\u3084PVDF\u30e1\u30f3\u30d6\u30ec\u30f3\uff08\u819c\uff09\u4e0a\u306b\u7d50\u5408\u3057\u305f\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u3001\u6297\u539f\u6297\u4f53\u53cd\u5fdc\u3092\u5229\u7528\u3057\u3066\u9593\u63a5\u7684\u306b\u691c\u51fa\u3057\u307e\u3059\u3002\u5b9a\u6cd5\u3067\u306f\u307e\u305aSDS-\u30dd\u30ea\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\uff08SDS-PAGE\uff09\u3092\u7528\u3044\u3066\u30bf\u30f3\u30d1\u30af\u8cea\u8a66\u6599\u3092\u5206\u5b50\u91cf\u306e\u9055\u3044\u306b\u3088\u308a\u5206\u96e2\u3057\u305f\u5f8c\u3001\u30b2\u30eb\u304b\u3089\u30e1\u30f3\u30d6\u30ec\u30f3\u3078\u96fb\u6c17\u7684\u306b\u8ee2\u5199\u3055\u305b\u307e\u3059\u3002\u8ee2\u5199\u306b\u306f\u3001\u30bf\u30f3\u30af\u5f0f\uff08\u30a6\u30a7\u30c3\u30c8\u5f0f\uff09\u3084\u30bb\u30df\u30c9\u30e9\u30a4\u5f0f\u3068\u8a00\u308f\u308c\u308b\u65b9\u6cd5\u304c\u3042\u308a\u3001\u8ee2\u5199\u52b9\u7387\u3084\u8ee2\u5199\u6642\u9593\u3001\u64cd\u4f5c\u6027\u306a\u3069\u3092\u8003\u616e\u3057\u3066\u5404\u7a2e\u624b\u6cd5\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u7d50\u5408\u3057\u305f\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u30d6\u30ed\u30c3\u30c8\u9762\u306f\u3001\u9069\u5f53\u306a\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3067\u51e6\u7406\u3057\u305f\u5f8c\u3001\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306b\u5bfe\u3059\u308b\u4e00\u6b21\u6297\u4f53\uff08\u30dd\u30ea\u30af\u30ed\u30fc\u30ca\u30eb\u307e\u305f\u306f\u30e2\u30ce\u30af\u30ed\u30fc\u30ca\u30eb\uff09\u3092\u53cd\u5fdc\u3055\u305b\u307e\u3059\uff08\u30d7\u30ed\u30fc\u30d3\u30f3\u30b0\uff09\u3002\u6d17\u6d44\u30b9\u30c6\u30c3\u30d7\u306b\u3088\u308a\u672a\u53cd\u5fdc\u306e\u4e00\u6b21\u6297\u4f53\u3092\u53d6\u308a\u9664\u3044\u305f\u5f8c\u3001\u7d9a\u3044\u3066\u4e00\u6b21\u6297\u4f53\u3092\u8a8d\u8b58\u3059\u308b\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3068\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002\u6a19\u8b58\u9175\u7d20\u3068\u3057\u3066\u306f\u30a2\u30eb\u30ab\u30ea\u30d5\u30a9\u30b9\u30d5\u30a1\u30bf\u30fc\u30bc\uff08AP\uff09\u307e\u305f\u306f\u897f\u6d0b\u308f\u3055\u3073\u30d1\u30fc\u30aa\u30ad\u30b7\u30c0\u30fc\u30bc\uff08HRP\uff09\u304c\u6700\u3082\u4e00\u822c\u7684\u3067\u3059\u3002\u3055\u3089\u306b\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6d17\u6d44\u3057\u3066\u304b\u3089\u9175\u7d20\u306b\u5fdc\u3058\u305f\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002<\/p>\n<p>\u3053\u306e\u3088\u3046\u306b\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f\u6297\u539f\u3068\u6297\u4f53\u306e\u7279\u7570\u7684\u306a\u53cd\u5fdc\u3092\u5229\u7528\u3057\u3001\u9175\u7d20\u53cd\u5fdc\u306b\u3088\u308a\u751f\u3058\u308b\u30b7\u30b0\u30ca\u30eb\u3092\u5f97\u308b\u3053\u3068\u3067\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u9593\u63a5\u7684\u306b\u691c\u51fa\u3057\u307e\u3059\u3002\u5316\u5b66\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u306e\u5834\u5408\u306fCCD\u30ab\u30e1\u30e9\u306a\u3069\u3092\u642d\u8f09\u3057\u305f\u30a4\u30e1\u30fc\u30b8\u30f3\u30b0\u30b7\u30b9\u30c6\u30e0\u3084X\u7dda\u30d5\u30a3\u30eb\u30e0\u3078\u306e\u9732\u5149\u306b\u3088\u308a\u30d0\u30f3\u30c9\u3068\u3057\u3066\u691c\u51fa\u3057\u307e\u3059\u3002\u611f\u5ea6\u306e\u9ad8\u3044\u5316\u5b66\u767a\u5149\u57fa\u8cea\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u30d5\u30a7\u30e0\u30c8\u30b0\u30e9\u30e0\u30ec\u30d9\u30eb\u306e\u691c\u51fa\u3082\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u4eca\u56de\u306f\u3001<strong>\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u4e00\u822c\u539f\u7406\u3068\u5404\u30b9\u30c6\u30c3\u30d7\u3067\u7d50\u679c\u306b\u5f71\u97ff\u3059\u308b\u8981\u56e0<\/strong>\u306b\u95a2\u3057\u3066\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u5f0a\u793e\u88fd\u54c1\u3092\u5f15\u7528\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u7528\u3044\u308b\u4e00\u822c\u7684\u306a\u5897\u5f37\u5316\u5b66\u767a\u5149\u30a2\u30c3\u30bb\u30a4\u306b\u3082\u9069\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n<h2>\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u30bf\u30a4\u30d7\u3068\u5f71\u97ff\u3059\u308b\u8981\u56e0<\/h2>\n<p><strong>\u6700\u3082\u4e00\u822c\u7684\u306a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u57fa\u8cea\u306f\u30eb\u30df\u30ce\u30fc\u30eb\u30d9\u30fc\u30b9\u306e\u5316\u5b66\u767a\u5149\u57fa\u8cea\u3067\u3059\u3002<\/strong>\u5316\u5b66\u767a\u5149\u306f\u30a8\u30cd\u30eb\u30ae\u30fc\u3092\u5149\u3068\u3057\u3066\u653e\u51fa\u3059\u308b\u5316\u5b66\u53cd\u5fdc\u3067\u3059\u3002\u897f\u6d0b\u308f\u3055\u3073\u30d1\u30fc\u30aa\u30ad\u30b7\u30c0\u30fc\u30bc\uff08HRP\uff09\u3068\u904e\u9178\u5316\u6c34\u7d20\u306e\u5b58\u5728\u4e0b\u3067\u306f\u30eb\u30df\u30ce\u30fc\u30eb\u306f\u9178\u5316\u3055\u308c\u52b1\u8d77\u72b6\u614b\u306e\u53cd\u5fdc\u751f\u6210\u7269\u3092\u5f62\u6210\u3057\u307e\u3059\u3002\u3053\u306e\u53cd\u5fdc\u751f\u6210\u7269\u304c\u52b1\u8d77\u72b6\u614b\u304b\u3089\u57fa\u5e95\u72b6\u614b\u306b\u623b\u308b\u969b\u306e\u30a8\u30cd\u30eb\u30ae\u30fc\u304c\u5149\u3068\u3057\u3066\u653e\u51fa\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u653e\u51fa\u5149\u306f\u9175\u7d20\u57fa\u8cea\u53cd\u5fdc\u306e\u9593\u3060\u3051\u751f\u3058\u308b\u305f\u3081\u3001\u9175\u7d20\u306e\u8fd1\u508d\u306b\u5b58\u5728\u3059\u308b\u57fa\u8cea\u304c\u6d88\u8cbb\u3055\u308c\u308c\u3070\u653e\u51fa\u5149\u306f\u9014\u7d76\u3048\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u5bfe\u79f0\u7684\u306bDAB\u306a\u3069\u306e\u767a\u8272\u57fa\u8cea\u3067\u306f\u9175\u7d20\u57fa\u8cea\u53cd\u5fdc\u304c\u505c\u6b62\u3057\u305f\u5f8c\u3082\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u6b8b\u308b\u6c88\u964d\u7269\u3092\u751f\u3058\u307e\u3059\u3002<\/p>\n<h3>\u30b7\u30b0\u30ca\u30eb\u306e\u691c\u51fa<\/h3>\n<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u304c\u4e00\u822c\u7684\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u306a\u3063\u3066\u4e45\u3057\u3044\u3067\u3059\u304c\u3001<strong>S\/N\u6bd4\u306e\u9ad8\u3044\u6700\u9069\u306a\u30d0\u30f3\u30c9\u3092\u5f97\u308b\u306e\u306f\u7c21\u5358\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/strong>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306f\u624b\u6280\u3092\u8981\u3059\u308b\u4e00\u9023\u306e\u9023\u7d50\u3057\u305f\u30b9\u30c6\u30c3\u30d7\u304b\u3089\u69cb\u6210\u3055\u308c\u308b\u305f\u3081\u3001\u6700\u7d42\u7684\u306a\u30b7\u30b0\u30ca\u30eb\u7372\u5f97\u306b\u306f\u9014\u4e2d\u306e\u3055\u307e\u3056\u307e\u306a\u8981\u7d20\u304c\u95a2\u9023\u3059\u308b\u304b\u3089\u3067\u3059\u3002\u591a\u304f\u306e\u5909\u52d5\u7684\u306a\u8981\u7d20\u304c\u95a2\u4e0e\u3059\u308b\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306e\u554f\u984c\u3092\u89e3\u6c7a\u3059\u308b\u3053\u3068\u306f\u3001\u5e72\u3057\u8349\u306e\u5c71\u304b\u3089\u91dd\u3092\u63a2\u3057\u51fa\u3059\u3053\u3068\u306b\u3082\u4f3c\u3066\u3044\u307e\u3059\uff08\u88681\uff09\u3002\u65e2\u5b58\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u306b\u6cbf\u3063\u3066\u3044\u3066\u3082\u7279\u5b9a\u306e\u30b5\u30f3\u30d7\u30eb\u306e\u691c\u51fa\u304c\u96e3\u3057\u3044\u3053\u3068\u306f\u3088\u304f\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u305f\u3068\u3048\u3070\u3001native\u306a\u9ad8\u6b21\u69cb\u9020\u3092\u4fdd\u6301\u3057\u305f\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u8a8d\u8b58\u3059\u308b\u4e00\u6b21\u6297\u4f53\u3092\u7528\u3044\u305f\u5834\u5408\u306b\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u56fa\u5b9a\u3055\u308c\u3066\u5909\u6027\u3057\u305f\u6297\u539f\u3092\u8a8d\u8b58\u3057\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u96fb\u6c17\u6cf3\u52d5\u3092\u975e\u5909\u6027\u6761\u4ef6\u4e0b\u3067\u884c\u3063\u305f\u5834\u5408\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u5f8c\u306e\u6297\u539f\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u30cd\u30a4\u30c6\u30a3\u30d6\u306a\u69cb\u9020\u3092\u4fdd\u6301\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u691c\u51fa\u3067\u304d\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30d0\u30f3\u30c9\u3068\u3057\u3066\u691c\u51fa\u3067\u304d\u305f\u3068\u3057\u3066\u3082\u3001\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5206\u5b50\u91cf\u306e\u7279\u5b9a\u306f\u56f0\u96e3\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u3055\u3089\u306b\u975e\u5e38\u306b\u9ad8\u5206\u5b50\u91cf\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3084\u758e\u6c34\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u306f\u30e1\u30f3\u30d6\u30ec\u30f3\u3078\u306e\u52b9\u7387\u7684\u306a\u8ee2\u5199\u304c\u96e3\u3057\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3088\u308a\u78ba\u5b9f\u306b\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u691c\u51fa\u3067\u304d\u308b\u3088\u3046\u306b1979\u5e74\u306b\u306f\u3058\u3081\u3066\u7d39\u4ecb\u3055\u308c\u305fTowbin\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u306f\u3053\u308c\u307e\u3067\u4f55\u5ea6\u3082\u6539\u5909\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u3042\u3048\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u3078\u306e\u8ee2\u5199\u3092\u907f\u3051\u3066\u30b2\u30eb\u5185\u3067\u691c\u51fa\u3059\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<table>\n<caption>\u88681 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u5f71\u97ff\u3059\u308b\u8981\u56e0<\/caption>\n<tbody>\n<tr>\n<td>\u8981\u56e0<\/td>\n<td>\u5909\u52d5\u7279\u6027<\/td>\n<\/tr>\n<tr>\n<td>\u6297\u539f\uff08\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\uff09<\/td>\n<td>\u7acb\u4f53\u69cb\u9020\u3001\u5b89\u5b9a\u6027\u3001\u30a8\u30d4\u30c8\u30fc\u30d7<\/td>\n<\/tr>\n<tr>\n<td>\u30dd\u30ea\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u30b2\u30eb<\/td>\n<td>\u30b2\u30eb\u88fd\u9020\u5143\u3001\u30a2\u30af\u30ea\u30eb\u30a2\u30df\u30c9\u6fc3\u5ea6\u3001\u4fdd\u5b58\u671f\u9593\u3001\u88fd\u9020\u30ed\u30c3\u30c8<\/td>\n<\/tr>\n<tr>\n<td>\u30e1\u30f3\u30d6\u30ec\u30f3<\/td>\n<td>\u30e1\u30f3\u30d6\u30ec\u30f3\u88fd\u9020\u5143\u3001\u30bf\u30a4\u30d7\u3001\u88fd\u9020\u30ed\u30c3\u30c8<\/td>\n<\/tr>\n<tr>\n<td>\u4e00\u6b21\u6297\u4f53<\/td>\n<td>\u7279\u7570\u6027\u3001\u529b\u4fa1\u3001\u89aa\u548c\u6027\u3001\u53cd\u5fdc\u6642\u9593\u304a\u3088\u3073\u53cd\u5fdc\u6e29\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>HRP\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53<\/td>\n<td>\u9175\u7d20\u6a19\u8b58\u30ec\u30d9\u30eb\u3068\u9175\u7d20\u6d3b\u6027\u3001\u30db\u30b9\u30c8\u52d5\u7269\u7a2e\u3001\u6fc3\u5ea6<\/td>\n<\/tr>\n<tr>\n<td>\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc<\/td>\n<td>\u30bf\u30a4\u30d7\u3001\u6fc3\u5ea6\u3001\u4ea4\u53c9\u53cd\u5fdc\u6027<\/td>\n<\/tr>\n<tr>\n<td>\u6d17\u6d44<\/td>\n<td>\u30d0\u30c3\u30d5\u30a1\u30fc\u3001\u4f7f\u7528\u91cf\u3001\u6d17\u6d44\u6642\u9593\u3001\u6d17\u6d44\u56de\u6570<\/td>\n<\/tr>\n<tr>\n<td>\u57fa\u8cea<\/td>\n<td>\u611f\u5ea6\u3001\u88fd\u9020\u30ed\u30c3\u30c8\u3001\u4fdd\u5b58\u671f\u9593<\/td>\n<\/tr>\n<tr>\n<td>\u691c\u51fa\u6cd5<\/td>\n<td>\u4fdd\u5b58\u671f\u9593\u3001\u88fd\u9020\u5143<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u3068\u30b7\u30b0\u30ca\u30eb\u7d99\u7d9a\u6642\u9593<\/h3>\n<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u5404\u6761\u4ef6\u304c\u4f7f\u7528\u3059\u308b\u57fa\u8cea\u306b\u81f3\u9069\u5316\u3055\u308c\u3066\u3044\u308c\u3070\u3001\u5316\u5b66\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u306f\u5c11\u306a\u304f\u3068\u30826-24\u6642\u9593\uff08\u5f0a\u793e\u88fd\u54c1\u306e<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/life-science\/protein-biology\/protein-assays-analysis\/western-blotting\/detect-proteins-western-blot\/western-blot-detection-reagents\/chemiluminescent-western-blot-detection\/chemiluminescent-substrates-performance-data.html?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">SuperSignal\u30b7\u30ea\u30fc\u30ba<\/a>\u306e\u5834\u5408\uff09\u7d99\u7d9a\u3057\u307e\u3059\u3002\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u3068\u7d99\u7d9a\u6642\u9593\u306f\u691c\u51fa\u306b\u7528\u3044\u3089\u308c\u308b\u7279\u5b9a\u306e\u5316\u5b66\u767a\u5149\u57fa\u8cea\u3068\u691c\u51fa\u7cfb\u306b\u5b58\u5728\u3059\u308b\u9175\u7d20-\u57fa\u8cea\u6bd4\u306b\u4f9d\u5b58\u3057\u307e\u3059\u3002<\/p>\n<p>\u30d6\u30ed\u30c3\u30c8\u4e0a\u306e\u5316\u5b66\u767a\u5149\u57fa\u8cea\u306f\u76f8\u5bfe\u7684\u306b\u4e00\u5b9a\u3067\u3059\u304c\u3001\u5b58\u5728\u3059\u308b\u9175\u7d20\u91cf\u306f\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306e\u6297\u539f\u91cf\u3068\u6dfb\u52a0\u3055\u308c\u305f\u4e00\u6b21\u6297\u4f53\u91cf\u3068\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306b\u4f9d\u5b58\u3057\u307e\u3059\uff08\u88681\uff09\u3002<strong>\u9175\u7d20\u6a19\u8b58\u7269\u304c\u691c\u51fa\u7cfb\u306b\u904e\u5270\u306b\u5b58\u5728\u3059\u308b\u3068\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u4e0a\u6607\u30fb\u30b7\u30b0\u30ca\u30eb\u7d99\u7d9a\u6642\u9593\u306e\u77ed\u7e2e\u30fb\u611f\u5ea6\u306e\u4f4e\u4e0b\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u6700\u3082\u983b\u5ea6\u306e\u9ad8\u3044\u4e0d\u5177\u5408\u306e\u539f\u56e0\u3067\u3059\u3002<\/strong>\u3086\u3063\u304f\u308a\u3068\u5f37\u5ea6\u6e1b\u8870\u3059\u308b\u30a8\u30df\u30c3\u30b7\u30e7\u30f3\u30ab\u30fc\u30d6\uff08\u56f31\uff09\u306f\u7406\u60f3\u7684\u3067\u3042\u308a\u3001\u3053\u308c\u306f\u691c\u51fa\u7cfb\u304c\u81f3\u9069\u5316\u3055\u308c\u4fe1\u983c\u3067\u304d\u308b\u7d50\u679c\u304c\u5f97\u3089\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002\u6025\u901f\u306b\u6e1b\u8870\u3059\u308b\u30b7\u30b0\u30ca\u30eb\u306f\u7d50\u679c\u306e\u5909\u52d5\u6027\u3084\u611f\u5ea6\u306e\u4f4e\u4e0b\u306e\u539f\u56e0\u3068\u306a\u308a\u3001\u30b7\u30b0\u30ca\u30eb\u306e\u753b\u50cf\u5316\u3055\u3048\u3067\u304d\u306a\u3044\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u9577\u304f\u5b89\u5b9a\u7684\u306b\u7d99\u7d9a\u3059\u308b\u30b7\u30b0\u30ca\u30eb\u306f\u8ee2\u5199\u52b9\u7387\u3084\u57fa\u8cea\u306e\u88fd\u9020\u30ed\u30c3\u30c8\u9593\u3067\u306e\u5909\u52d5\u3092\u6700\u5c11\u306b\u6291\u3048\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002HRP\u304c\u57fa\u8cea\u306b\u7279\u6709\u306a\u767a\u5149\u7d99\u7d9a\u6642\u9593\u5185\u305d\u306e\u6d3b\u6027\u3092\u7dad\u6301\u3067\u304d\u308b\u3068\u3057\u3066\u3082\u3001\u30eb\u30df\u30ce\u30fc\u30eb\u304cHRP\u3092\u56de\u8ee2\u3055\u305b\u5931\u6d3b\u3055\u305b\u308b\u3053\u3068\u304c\u6307\u6458\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u9178\u5316\u53cd\u5fdc\u306e\u969b\u306b\u751f\u3058\u308b\u30d5\u30ea\u30fc\u30e9\u30b8\u30ab\u30eb\u751f\u6210\u7269\u306fHRP\u306b\u7d50\u5408\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u305d\u3046\u306a\u308b\u3068HRP\u306f\u3082\u306f\u3084\u57fa\u8cea\u3068\u76f8\u4e92\u4f5c\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u306a\u304f\u306a\u308a\u307e\u3059\u3002\u691c\u51fa\u7cfb\u306b\u904e\u5270\u306b\u5b58\u5728\u3059\u308bHRP\u306f\u904e\u5270\u306a\u30d5\u30ea\u30fc\u30e9\u30b8\u30ab\u30eb\u3092\u751f\u307f\u51fa\u3057\u3001HRP\u5931\u6d3b\u306e\u53ef\u80fd\u6027\u3092\u9ad8\u3081\u307e\u3059\u3002\u3055\u3089\u306b\u30d5\u30ea\u30fc\u30e9\u30b8\u30ab\u30eb\u306f\u6297\u539f\u306b\u3082\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u305f\u3081\u518d\u30d7\u30ed\u30fc\u30d6\u306e\u969b\u306e\u691c\u51fa\u306b\u3082\u5f71\u97ff\u304c\u3067\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1028\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-fig1.jpg\" rel=\"attachment wp-att-1028\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1028\" class=\"size-full wp-image-1028\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-fig1.jpg\" alt=\"chemiluminescent-westernblotting-fig1\" width=\"500\" height=\"354\" \/><\/a><p id=\"caption-attachment-1028\" class=\"wp-caption-text\">\u56f31 \u5316\u5b66\u767a\u5149\u6cd5\u306b\u304a\u3044\u3066\u904e\u5270\u91cf\u306e\u9175\u7d20\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306b\u898b\u3089\u308c\u308b\u73fe\u8c61\u3002\u904e\u5270\u306e\u9175\u7d20\u6a19\u8b58\u6297\u4f53\u3092\u7528\u3044\u308b\u3068\u4e0b\u8a18\u306e\u3088\u3046\u306a\u73fe\u8c61\u304c\u307f\u3089\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u6642\u306f\u6297\u4f53\u6fc3\u5ea6\uff08\u5e0c\u91c8\u7387\uff09\u306e\u81f3\u9069\u5316\u3092\u884c\u3044\u307e\u3059\u3002<\/p><\/div>\n<h3>\u76f4\u63a5\u6cd5\u3068\u9593\u63a5\u6cd5<\/h3>\n<p><strong>\u76f4\u63a5\u6cd5\u3067\u306f\u6a19\u8b58\u4e00\u6b21\u6297\u4f53\u3092\u7528\u3044\u307e\u3059\u3002<\/strong>\u4e8c\u6b21\u6297\u4f53\u3068\u306e\u53cd\u5fdc\u304c\u7701\u304b\u308c\u308b\u305f\u3081\u3001\u9593\u63a5\u6cd5\u3068\u6bd4\u3079\u3066\u77ed\u6642\u9593\u3067\u7d42\u4e86\u3057\u307e\u3059\u3002\u3055\u3089\u306b\u4e8c\u6b21\u6297\u4f53\u306e\u4ea4\u53c9\u53cd\u5fdc\u306b\u7531\u6765\u3059\u308b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u306e\u5fc3\u914d\u3082\u3042\u308a\u307e\u305b\u3093\u3002\u540c\u6642\u306b\u8907\u6570\u306e\u6297\u539f\u3092\u30d7\u30ed\u30fc\u30d6\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd\u3067\u3059\u3002\u305f\u3060\u3057\u4e00\u6b21\u6297\u4f53\u3078\u306e\u6a19\u8b58\u306f\u6297\u539f\u8a8d\u8b58\u306b\u4e0d\u90fd\u5408\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u3055\u3089\u306b\u3059\u3079\u3066\u306e\u6761\u4ef6\u304c\u81f3\u9069\u5316\u3055\u308c\u3066\u3044\u305f\u3068\u3057\u3066\u3082\u9593\u63a5\u6cd5\u3067\u5f97\u3089\u308c\u308b\u3088\u3046\u306a\u30b7\u30b0\u30ca\u30eb\u306e\u5897\u5e45\u306f\u8d77\u3053\u308a\u307e\u305b\u3093\u3002<strong>\u5fc5\u7136\u7684\u306b\u76f4\u63a5\u6cd5\u3067\u5f97\u3089\u308c\u308b\u691c\u51fa\u611f\u5ea6\u306f\u9593\u63a5\u6cd5\u306b\u6bd4\u3079\u3066\u4f4e\u304f\u3001\u6297\u539f\u304c\u6bd4\u8f03\u7684\u8c4a\u5bcc\u306b\u5b58\u5728\u3059\u308b\u5834\u5408\u306b\u306e\u307f\u884c\u308f\u308c\u307e\u3059\u3002<\/strong>\u76f4\u63a5\u6cd5\u306e\u9078\u629e\u80a2\u3068\u3057\u3066\u306f\u4e00\u6b21\u6297\u4f53\u306e\u30d3\u30aa\u30c1\u30f3\u5316\u304c\u3042\u308a\u3001\u9593\u63a5\u6cd5\u3067\u3042\u308a\u306a\u304c\u3089\u4e8c\u6b21\u6297\u4f53\u3092\u4f7f\u7528\u305b\u305a\u306b\u30b7\u30b0\u30ca\u30eb\u306e\u5897\u5e45\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002\u30d3\u30aa\u30c1\u30f3\u5316\u8a66\u85ac\u306b\u3088\u308b\u6a19\u8b58\u3067\u306f\u4e00\u822c\u7684\u306b\u6297\u4f531\u5206\u5b50\u3042\u305f\u308a\u8907\u6570\u306e\u30d3\u30aa\u30c1\u30f3\u3092\u4fee\u98fe\u3059\u308b\u3088\u3046\u306a\u30d7\u30ed\u30c8\u30b3\u30eb\u3067\u884c\u308f\u308c\u307e\u3059\u3002\u30d3\u30aa\u30c1\u30f31\u5206\u5b50\u306b\u5bfe\u3057\u3066HRP\u304c\u6a19\u8b58\u3055\u308c\u305f\u30a2\u30d3\u30b8\u30f3\u3084\u30b9\u30c8\u30ec\u30d7\u30c8\u30a2\u30d3\u30b8\u30f3\u307e\u305f\u306f<a href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/references\/molecular-probes-the-handbook\/tables\/molecular-probes-selection-of-avidin-streptavidin-neutravidin-and-captavidin-conjugates.html?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">NeutrAvidin<\/a>\u304c\u7d50\u5408\u3059\u308b\u3053\u3068\u3067\u30b7\u30b0\u30ca\u30eb\u306e\u5897\u5e45\u3092\u304a\u3053\u306a\u3046\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001HRP\u6a19\u8b58\u30a2\u30d3\u30b8\u30f3\u306f\u4e8c\u6b21\u6297\u4f53\u306e\u4ee3\u308f\u308a\u306b\u4f7f\u7528\u3055\u308c\u3001\u307e\u305f\u4f7f\u7528\u6642\u306e\u30e2\u30eb\u6fc3\u5ea6\u306f\u57fa\u672c\u7684\u306b\u306f\u4e8c\u6b21\u6297\u4f53\u306e\u5834\u5408\u3068\u540c\u3058\u3067\u3059\u3002<\/p>\n<h3>\u30d5\u30a1\u30fc\u30a6\u30a7\u30b9\u30bf\u30f3\u6cd5<\/h3>\n<p>\u6297\u539f\u7279\u7570\u6297\u4f53\u306e\u4f7f\u7528\u304c\u9069\u5207\u3067\u306a\u3044\u5834\u5408\u3084\u5229\u7528\u3067\u304d\u308b\u6297\u4f53\u304c\u5b58\u5728\u3057\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<strong>\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea\u3068\u4f5c\u7528\u3059\u308b\u30bf\u30f3\u30d1\u30af\u8cea\uff08\u7d50\u5408\u30d1\u30fc\u30c8\u30ca\u30fc\uff09\u3092\u30d7\u30ed\u30fc\u30d6\u306b\u5229\u7528\u3067\u304d\u308c\u3070\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306f\u53ef\u80fd\u3067\u3059\u3002<\/strong>\u3053\u306e\u624b\u6cd5\u306f\u30d5\u30a1\u30fc\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\u3068\u547c\u3070\u308c\u30bf\u30f3\u30d1\u30af\u8cea-\u30bf\u30f3\u30d1\u30af\u8cea\u9593\u306e\u76f8\u4e92\u4f5c\u7528\uff08PPI; Protein:Protein Interaction\uff09\u691c\u51fa\u306b\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u76f8\u4e92\u4f5c\u7528\u691c\u51fa\u306b\u306f\u7121\u6570\u306e\u624b\u6cd5\u304c\u3042\u308a\u3001\u3055\u307e\u3056\u307e\u306a\u30b9\u30c8\u30e9\u30c6\u30b8\u30fc\u304c\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u6297\u4f53\u3092\u7528\u3044\u308b\u624b\u6cd5\u3068\u540c\u69d8\u306b\u3001\u6a19\u8b58\u3055\u308c\u305f\u7d50\u5408\u30d1\u30fc\u30c8\u30ca\u30fc\u304c\u7528\u3044\u3089\u308c\u3001\u6a19\u8b58\u306b\u306f35S\u306b\u3088\u308bin-vitro\u3067\u306e\u53cd\u5fdc\u3082\u5229\u7528\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u306f\u30d7\u30ed\u30fc\u30d6\u306e\u30d3\u30aa\u30c1\u30f3\u5316\u3068\u6a19\u8b58\u3055\u308c\u305f\u30a2\u30d3\u30b8\u30f3\u307e\u305f\u306f\u30a2\u30d3\u30b8\u30f3\u69d8\u30bf\u30f3\u30d1\u30af\u8cea\u304c\u4f7f\u7528\u3055\u308c\u3001\u30b7\u30b0\u30ca\u30eb\u306e\u5897\u5e45\u304c\u56f3\u3089\u308c\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u7d50\u5408\u30d1\u30fc\u30c8\u30ca\u30fc\u3078\u306e\u904e\u5270\u6a19\u8b58\u306b\u3088\u3063\u3066\u76f8\u4e92\u4f5c\u7528\u3092\u963b\u5bb3\u3057\u306a\u3044\u3088\u3046\u306b\u7d30\u5fc3\u306e\u6ce8\u610f\u3092\u306f\u3089\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002GST, HA, c-Myc, FLAG\u306a\u3069\u306e\u30bf\u30b0\u3068\u5171\u767a\u73fe\u3055\u305b\u305f\u7d44\u63db\u3048\u578b\u30d7\u30ed\u30fc\u30d6\u3068\u30bf\u30b0\u6297\u4f53\u3092\u7528\u3044\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u30a6\u30a7\u30b9\u30bf\u30f3\u540c\u69d8\u306b\u30d5\u30a1\u30fc\u30a6\u30a7\u30b9\u30bf\u30f3\u3067\u3082\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u307e\u305f\u306f\u30b2\u30eb\u5185\u3067\u691c\u51fa\u3055\u308c\u307e\u3059\u3002<\/p>\n<h2>\u5316\u5b66\u767a\u5149\u30a6\u30a8\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6700\u9069\u5316<\/h2>\n<p>\u5404\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\u3067\u4e00\u8cab\u3057\u305f\u826f\u597d\u306a\u7d50\u679c\u3092\u5f97\u308b\u306b\u306f\u5b9f\u9a13\u7cfb\u3092\u81f3\u9069\u5316\u3057\u306a\u3051\u308c\u3070\u3044\u3051\u307e\u305b\u3093\u3002\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u3084\u30b7\u30b0\u30ca\u30eb\u7d99\u7d9a\u6642\u9593\u306b\u306f\u3055\u307e\u3056\u307e\u306a\u8981\u56e0\u304c\u5f71\u97ff\u3059\u308b\u305f\u3081\u3001\u5404\u8981\u56e0\u3092\u305d\u308c\u305e\u308c\u81f3\u9069\u5316\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u3067\u306f\u5404\u8981\u56e0\u306e\u81f3\u9069\u5316\u306b\u3064\u3044\u3066\u89e6\u308c\u3001\u30d7\u30ed\u30c8\u30b3\u30eb\u30fb\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u306f\u81f3\u9069\u5316\u64cd\u4f5c\u306b\u95a2\u3059\u308b\u7c21\u5358\u306a\u30a4\u30f3\u30b9\u30c8\u30e9\u30af\u30b7\u30e7\u30f3\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n<h3>\u30e1\u30f3\u30d6\u30ec\u30f3<\/h3>\n<p>HRP-\u30eb\u30df\u30ce\u30fc\u30eb\u306e\u53cd\u5fdc\u3068\u767a\u751f\u3059\u308b\u30b7\u30b0\u30ca\u30eb\u306f\u4e00\u822c\u7684\u306b\u306f\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u7d44\u6210\u306b\u306f\u5f71\u97ff\u3055\u308c\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\uff08NC\uff09\u30e1\u30f3\u30d6\u30ec\u30f3\u3084PVDF\u30e1\u30f3\u30d6\u30ec\u30f3\u306f\u30bf\u30f3\u30d1\u30af\u7d50\u5408\u7279\u6027\u304c\u7570\u306a\u308a\u3001<strong>\u4e00\u822c\u7684\u306bPVDF\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u7d50\u5408\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u3082\u9ad8\u304f\u3001\u53d6\u6271\u3044\u3082\u5bb9\u6613\u3067\u3059\u304c\u3001\u6c34\u548c\u306b\u306f\u30e1\u30bf\u30ce\u30fc\u30eb\u51e6\u7406\u304c\u5fc5\u8981\u3067\u3059\u3002NC\u30e1\u30f3\u30d6\u30ec\u30f3\u306f\u7c21\u5358\u306b\u6c34\u548c\u3067\u304d\u3001\u30c9\u30c3\u30c8\u30d6\u30ed\u30c3\u30c8\u306b\u4fbf\u5229\u3067\u3059\u3002<\/strong>\u5404\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u7cfb\u3067\u30e1\u30f3\u30d6\u30ec\u30f3\u30bf\u30a4\u30d7\u3001\u88fd\u9020\u5143\u3001\u88fd\u9020\u30ed\u30c3\u30c8\u306b\u95a2\u3057\u3066\u7d4c\u9a13\u7684\u306b\u6700\u9069\u306a\u88fd\u54c1\u3092\u6c7a\u5b9a\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u4e00\u5ea6\u3001\u305d\u306e\u7cfb\u3067\u6700\u9069\u306a\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6c7a\u5b9a\u3057\u305f\u3089\u3001\u3067\u304d\u308b\u304b\u304e\u308a\u540c\u4e00\u30ed\u30c3\u30c8\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u4f7f\u3044\u7d9a\u3051\u308b\u3053\u3068\u3082\u5927\u5207\u3067\u3059\u3002<\/p>\n<h3>\u76ee\u7684\u30bf\u30f3\u30d1\u30af\u8cea<\/h3>\n<p>\u8ee2\u5199\u52b9\u7387\u306f\u30bf\u30f3\u30d1\u30af\u8cea\u9593\u3067\u5287\u7684\u306b\u7570\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30bf\u30f3\u30d1\u30af\u8cea\u306f\u30b2\u30eb\u304b\u3089\u306e\u79fb\u52d5\u5ea6\u3084\u30e1\u30f3\u30d6\u30ec\u30f3\u3078\u306e\u7d50\u5408\u7279\u6027\u3067\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u3002\u8ee2\u5199\u52b9\u7387\u306f\u30b2\u30eb\u306e\u7d44\u6210\u3001\u30b2\u30eb\u3068\u30e1\u30f3\u30d6\u30ec\u30f3\u3068\u306e\u63a5\u89e6\u3001\u96fb\u6975\u306e\u4f4d\u7f6e\u3001\u8ee2\u5199\u6642\u9593\u3001\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u5206\u5b50\u91cf\u3084\u7d44\u6210\u3001\u96fb\u5834\u306e\u5f37\u5ea6\u3001\u3055\u3089\u306b\u754c\u9762\u6d3b\u6027\u5264\u306e\u6709\u7121\u306a\u3069\u306e\u8981\u56e0\u306b\u4f9d\u5b58\u3057\u307e\u3059\u3002\u307b\u3068\u3093\u3069\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3067\u306f\u4f4e\u30a4\u30aa\u30f3\u5f37\u5ea6\u4e0b\u3068\u4f4e\u96fb\u6d41\u4e0b\u306e\u8ee2\u5199\u3067\u6700\u9069\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u8ee2\u5199\u52b9\u7387\u306f\u53ef\u9006\u7684\u306a\u30e1\u30f3\u30d6\u30ec\u30f3\u67d3\u8272\u306b\u3088\u308a\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n<h3>\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc<\/h3>\n<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u306f\u3055\u307e\u3056\u307e\u306a\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u304c\u5229\u7528\u3055\u308c\u307e\u3059\u3002<strong>\u3059\u3079\u3066\u306e\u691c\u51fa\u7cfb\u3067\u6700\u9069\u306a\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u306f\u5b58\u5728\u305b\u305a\u3001\u81f3\u9069\u5316\u306b\u306f\u4e88\u5099\u5b9f\u9a13\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/strong>\u81f3\u9069\u5316\u3055\u308c\u305f\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u306f\u30b7\u30b0\u30ca\u30eb\u30ce\u30a4\u30ba\u6bd4\u3092\u6700\u5927\u306b\u3057\u3066\u3001\u691c\u51fa\u7cfb\u3067\u7528\u3044\u3089\u308c\u308b\u6297\u4f53\u3084\u6297\u539f\u3068\u306e\u7d50\u5408\u3092\u6700\u5c11\u306b\u6291\u3048\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3068\u3057\u3066\u6c4e\u7528\u3055\u308c\u308b5% \u30ce\u30f3\u30d5\u30a1\u30c3\u30c8\u30df\u30eb\u30af\u3092\u30a2\u30d3\u30b8\u30f3\/\u30d3\u30aa\u30c1\u30f3\u7cfb\u3067\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u30df\u30eb\u30af\u306b\u542b\u307e\u308c\u308b\u5185\u5728\u6027\u306e\u30d3\u30aa\u30c1\u30f3\u304c\u30a2\u30d3\u30b8\u30f3\u3068\u7d50\u5408\u3057\u3066\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u304c\u8457\u3057\u304f\u4e0a\u6607\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u57fa\u8cea\u3001\u6297\u4f53\u3001\u307e\u305f\u306f\u6297\u539f\u3092\u5909\u66f4\u3057\u305f\u5834\u5408\u3001\u5358\u306b\u65b0\u3057\u3044\u7cfb\u306b\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u304c\u81f3\u9069\u3067\u306a\u3044\u3068\u3044\u3046\u7406\u7531\u3060\u3051\u3067\u3001\u7279\u7570\u7684\u306a\u30b7\u30b0\u30ca\u30eb\u306e\u4f4e\u4e0b\u3084\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u306e\u4e0a\u6607\u304c\u751f\u3058\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001<strong>Tween\u00ae-20\u306a\u3069\u306e\u754c\u9762\u6d3b\u6027\u5264\u3092\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u6dfb\u52a0\u3059\u308b\u3053\u3068\u3067\u7d50\u679c\u304c\u6539\u5584\u3055\u308c\u308b\u691c\u51fa\u7cfb\u3082\u3042\u308a\u307e\u3059\u3002<\/strong>\u754c\u9762\u6d3b\u6027\u5264\u306f\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u304c\u6297\u4f53\u3068\u975e\u7279\u7570\u7684\u306b\u7d50\u5408\u3059\u308b\u3053\u3068\u3092\u963b\u6b62\u3057\u3066\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u6700\u5c0f\u306b\u6291\u3048\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u904e\u5270\u306a\u754c\u9762\u6d3b\u6027\u5264\u306e\u6dfb\u52a0\u306f\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3092\u59a8\u3052\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<strong>\u6700\u7d42\u6fc3\u5ea60.05%\u3067\u306e\u754c\u9762\u6d3b\u6027\u5264\u304c\u4e00\u822c\u7684\u306b\u7528\u3044\u3089\u308c\u307e\u3059<\/strong>\u304c\u3001\u7279\u5b9a\u306e\u7cfb\u3067\u754c\u9762\u6d3b\u6027\u5264\u306e\u4f7f\u7528\u304c\u9069\u3057\u3066\u3044\u308b\u304b\u3001\u4f55%\u304c\u6700\u9069\u306a\u6fc3\u5ea6\u304b\u3092\u78ba\u304b\u3081\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3044\u305a\u308c\u306b\u305b\u3088\u4e0d\u7d14\u7269\u3092\u542b\u307e\u306a\u3044\u9ad8\u7d14\u5ea6\u306a\u754c\u9762\u6d3b\u6027\u5264\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u518d\u73fe\u6027\u306e\u9ad8\u3044\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u3082\u91cd\u8981\u3067\u3059\u3002<\/p>\n<h3>\u6297\u4f53<\/h3>\n<p>\u4e00\u6b21\u6297\u4f53\u306e\u6297\u539f\u306b\u5bfe\u3059\u308b\u89aa\u548c\u6027\u3060\u3051\u304c\u91cd\u8981\u3067\u306f\u306a\u304f\u3001<strong>\u4e00\u6b21\u6297\u4f53\u6fc3\u5ea6\u3068\u4e8c\u6b21\u6297\u4f53\u6fc3\u5ea6\u3082\u30b7\u30b0\u30ca\u30eb\u30a8\u30df\u30c3\u30b7\u30e7\u30f3\u306b\u306f\u5927\u304d\u304f\u5f71\u97ff\u3057\u307e\u3059<\/strong>\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u56fa\u5b9a\u3055\u308c\u308bHRP\u306f\u4e00\u6b21\u6297\u4f53\u6fc3\u5ea6\u3084\u4e8c\u6b21\u6297\u4f53\u6fc3\u5ea6\u306b\u4f9d\u5b58\u3057\u307e\u3059\u3002\u4e00\u6b21\u6297\u4f53\u3092\u6700\u5c11\u91cf\u306b\u6291\u3048\u308b\u3053\u3068\u306b\u306f\u6297\u539f\u7279\u7570\u7684\u306a\u7d50\u5408\u3092\u4fc3\u9032\u3057\u3066\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u4f4e\u304f\u6291\u5236\u3059\u308b\u3068\u3044\u3046\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3067\u9069\u5f53\u306a\u30b7\u30b0\u30ca\u30eb\u3092\u5f97\u308b\u3053\u3068\u306b\u5931\u6557\u3057\u305f\u5834\u5408\u3001\u691c\u51fa\u306b\u4f7f\u7528\u3055\u308c\u305f\u5168\u3066\u306e\u8a66\u85ac\u3092\u9664\u53bb\u3057\u3066\u304b\u3089\u4e00\u6b21\u6297\u4f53\u3092\u5909\u66f4\u3059\u308b\u304b\u6297\u4f53\u6fc3\u5ea6\u3092\u5909\u66f4\u3057\u3066\u518d\u30d7\u30ed\u30fc\u30d6\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u8cb4\u91cd\u306a\u30b5\u30f3\u30d7\u30eb\u3068\u518d\u6cf3\u52d5\u306b\u5fc5\u8981\u306a\u6642\u9593\u3092\u7bc0\u7d04\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u6297\u4f53\u5265\u96e2\u304c\u4e0d\u5341\u5206\u3060\u3068\u4e00\u6b21\u6297\u4f53\u3084HRP\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3092\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u6b8b\u3059\u3053\u3068\u306b\u306a\u308a\u3001HRP\u6d3b\u6027\u304c\u7dad\u6301\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u306b\u306f\u5265\u96e2\u5f8c\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u57fa\u8cea\u3092\u6dfb\u52a0\u3059\u308b\u3053\u3068\u3067\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u3066\u3057\u307e\u3044\u307e\u3059\u3002<\/p>\n<p>\u307e\u305f\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u6b8b\u5b58\u3059\u308bHRP\u304c\u4e0d\u6d3b\u6027\u3067\u3042\u3063\u3066\u3082\u7d9a\u3044\u3066\u6dfb\u52a0\u3055\u308c\u308b\u4e00\u6b21\u6297\u4f53\u306e\u6297\u539f\u8a8d\u8b58\u304c\u963b\u5bb3\u3055\u308c\u308b\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u6297\u4f53\u5265\u96e2\u3068\u518d\u30d7\u30ed\u30fc\u30d6\u306f\u7cfb\u306b\u7279\u7570\u7684\u306a\u60c5\u5831\u3092\u5f97\u308b\u52b9\u679c\u7684\u306a\u624b\u6cd5\u3067\u3059\u304c\u3001\u6700\u9069\u306a\u7cfb\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u6c7a\u5b9a\u3059\u308b\u305f\u3081\u306e\u65b9\u6cd5\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n<h3>\u691c\u51fa\u6cd5<\/h3>\n<p>\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u30b7\u30b0\u30ca\u30eb\u691c\u51fa\u306b\u306f\u30d5\u30a3\u30eb\u30e0\u304c\u5f93\u6765\u304b\u3089\u7528\u3044\u3089\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u30d5\u30a3\u30eb\u30e0\u306f\u9ad8\u4fa1\u306a\u6a5f\u5668\u3092\u5fc5\u8981\u3068\u305b\u305a\u611f\u5ea6\u306e\u9ad8\u3044\u691c\u51fa\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002\u6b8b\u5ff5\u306a\u304c\u3089\u30d5\u30a3\u30eb\u30e0\u306f\u4e00\u56de\u3057\u304b\u4f7f\u7528\u3067\u304d\u305a\u3001\u30b7\u30b0\u30ca\u30eb\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u306f\u73fe\u50cf\u304c\u5fc5\u8981\u3067\u3059\u3002\u5b9f\u969b\u306b\u73fe\u50cf\u3059\u308b\u307e\u3067\u884c\u308f\u308c\u305f\u9732\u5149\u6642\u9593\u304c\u9069\u5207\u304b\u3069\u3046\u304b\u3092\u77e5\u308b\u3053\u3068\u306f\u3067\u304d\u306a\u3044\u305f\u3081\u3001\u30c8\u30e9\u30a4\uff06\u30a8\u30e9\u30fc\uff08\u901a\u5e38\u3001\u6570\u679a\u306e\u30d5\u30a3\u30eb\u30e0\uff09\u304c\u5fc5\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<p>\u30d5\u30a3\u30eb\u30e0\u306e\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u306f\u5e83\u304f\u3001\u9732\u5149\u904e\u5270\u306a\u30d5\u30a3\u30eb\u30e0\u3067\u3082\u30b7\u30b0\u30ca\u30eb\u30ce\u30a4\u30ba\u6bd4\u306f\u7dad\u6301\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u9732\u5149\u904e\u5270\u306a\u30d5\u30a3\u30eb\u30e0\u3082<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/21065?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce Background Eliminator Kit<\/a>\uff08\u56f32\uff09\u306a\u3069\u306e\u8a66\u85ac\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u30d5\u30a3\u30eb\u30e0\u5168\u4f53\u306e\u30b7\u30b0\u30ca\u30eb\u3092\u7b49\u3057\u304f\u4f4e\u6e1b\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u51b7\u5374CCD\u30ab\u30e1\u30e9\u3082\u73fe\u5728\u3067\u306f\u30b7\u30b0\u30ca\u30eb\u691c\u51fa\u306b\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<strong>\u3053\u308c\u3089\u306e\u30a4\u30e1\u30fc\u30b8\u30e3\u30fc\u3068\u95a2\u9023\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306b\u3088\u308b\u89e3\u6790\u306f\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u306e\u8abf\u6574\u3084\u30c7\u30f3\u30b7\u30c8\u30e1\u30c8\u30ea\u30fc\u89e3\u6790\uff08\u5199\u771f\u6fc3\u5ea6\u89e3\u6790\uff09\u3082\u53ef\u80fd\u3067\u3001\u30d5\u30a3\u30eb\u30e0\u30d9\u30fc\u30b9\u306e\u691c\u51fa\u306b\u6bd4\u3079\u3066\u5229\u70b9\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u5e83\u3044\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u3068\u9ad8\u5ea6\u306a\u9732\u5149\u5236\u5fa1\u306b\u3088\u308a\u3001\u30c7\u30fc\u30bf\u3092\u4e0d\u660e\u77ad\u306b\u3059\u308b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u3092\u88dc\u6b63\u3057\u305f\u30a4\u30e1\u30fc\u30b8\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3055\u3089\u306b\u9732\u5149\u6642\u9593\u306e\u81f3\u9069\u5316\u306b\u3088\u308a\u30b7\u30b0\u30ca\u30eb\u306e\u98fd\u548c\u3092\u9632\u304e\u308f\u305a\u304b\u306a\u6fc3\u5ea6\u5dee\u306e\u78ba\u8a8d\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002CCD\u30a4\u30e1\u30fc\u30b8\u30e3\u30fc\u306b\u6bd4\u3079\u308b\u3068\u30d5\u30a3\u30eb\u30e0\u306f\u30c0\u30a4\u30ca\u30df\u30c3\u30af\u30ec\u30f3\u30b8\u304c\u72ed\u304f\u3001\u3059\u3050\u306b\u30b7\u30b0\u30ca\u30eb\u304c\u98fd\u548c\u306b\u9054\u3059\u308b\u305f\u3081\u3001\u3057\u3070\u3057\u3070\u9732\u5149\u904e\u5270\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n<div id=\"attachment_1029\" style=\"width: 462px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-fig2.jpg\" rel=\"attachment wp-att-1029\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1029\" class=\"size-full wp-image-1029\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-fig2.jpg\" alt=\"chemiluminescent-westernblotting-fig2\" width=\"452\" height=\"347\" \/><\/a><p id=\"caption-attachment-1029\" class=\"wp-caption-text\">\u56f32 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/21065?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce Background Eliminator<\/a>\u306b\u3088\u308b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u8efd\u6e1b\u3002\u7d44\u63db\u3048\u578b\u30d2\u30c8TNF\u03b1\u30924-20% SDS-PAGE\u306b\u3088\u308a\u5206\u96e2\u3057\u3066\u30cb\u30c8\u30ed\u30bb\u30eb\u30ed\u30fc\u30b9\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3057\u307e\u3057\u305f\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u30d6\u30ed\u30c3\u30af\u5f8c\u3001Mouse anti-human TNF\u03b1 \u304a\u3088\u3073 Goat antimouse-HRP\u306b\u3088\u308a\u30d7\u30ed\u30fc\u30d6\u3001\u5316\u5b66\u767a\u5149\u57fa\u8cea<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/37071?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">SuperSignal West Dura Substrate<\/a>\u306b\u3088\u308a\u691c\u51fa\u3057\u307e\u3057\u305f\u3002\u9732\u5149\u6642\u959330\u79d2\u9593\u3067\u30d5\u30a3\u30eb\u30e0\u3092\u7528\u3044\u3066\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u3092\u753b\u50cf\u5316\uff08A\uff09\u3057\u3001\u3064\u3065\u3044\u3066\u30d5\u30a3\u30eb\u30e0\u3092Pierce Background Eliminator\u30672\u5206\u9593\u51e6\u7406(B)\u3057\u307e\u3057\u305f\u3002\u30d5\u30a3\u30eb\u30e0\u4e0a\u306e\u30b7\u30b0\u30ca\u30eb\u5f37\u5ea6\u3092\u5168\u4f53\u7684\u306b\u4e0b\u3052\u308b\u3053\u3068\u3067\u3001\u9732\u5149\u904e\u5270\u306a\u30d0\u30f3\u30c9\u3068\u30d0\u30c3\u30af\u30b0\u30e9\u30f3\u30c9\u4e0a\u306e\u30b7\u30df\u304c\u8efd\u6e1b\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3059\u3002<\/p><\/div>\n<h2>\u5316\u5b66\u767a\u5149\u30a6\u30a8\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u304a\u3051\u308b\u3088\u304f\u3042\u308b\u73fe\u8c61\u3068\u305d\u306e\u539f\u56e0<\/h2>\n<h3>\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u306a\u3044<\/h3>\n<p><strong>\u4e00\u56de\u76ee\u306e\u9732\u5149\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3067\u304d\u306a\u3044\u5834\u5408\u3001\u5b9f\u9a13\u7cfb\u304c\u81f3\u9069\u5316\u3055\u308c\u3066\u3044\u306a\u3044\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u30b7\u30b0\u30ca\u30eb\u306e\u6b20\u5982\u306f\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u5b58\u5728\u3059\u308b\u904e\u5270\u306aHRP\u304c\u539f\u56e0\u3068\u306a\u308b\u3053\u3068\u304c\u3088\u304f\u3042\u308a\u307e\u3059\u3002\u76f4\u89b3\u7684\u306b\u8003\u3048\u308b\u3068\u3001\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3067\u304d\u306a\u3044\u969b\u306bHRP\u91cf\u3092\u6e1b\u3089\u3059\u306e\u306f\u9006\u52b9\u679c\u306b\u611f\u3058\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001<strong>\u30b7\u30b0\u30ca\u30eb\u306e\u691c\u51fa\u3092\u6210\u529f\u3055\u305b\u308b\u306b\u306f\u9175\u7d20\u3068\u57fa\u8cea\u304c\u6b63\u3057\u3044\u30d0\u30e9\u30f3\u30b9\u3067\u5b58\u5728\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059<\/strong>\u3002\u9175\u7d20\u306b\u3088\u308b\u57fa\u8cea\u306e\u9178\u5316\u306f\u4e0d\u53ef\u9006\u306a\u53cd\u5fdc\u3067\u3042\u308a\u3001\u4e00\u5ea6\u9178\u5316\u3055\u308c\u305f\u57fa\u8cea\u306f\u9175\u7d20\u3068\u7d50\u5408\u3059\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u9175\u7d20\u6d3b\u6027\u306f\u9577\u6642\u9593\u7d99\u7d9a\u3059\u308b\u305f\u3081\u3001\u5316\u5b66\u767a\u5149\u3067\u306f\u57fa\u8cea\u304c\u6700\u5927\u306e\u5236\u9650\u56e0\u5b50\u3068\u306a\u308a\u3001\u57fa\u8cea\u304c\u5b8c\u5168\u306b\u6d88\u8cbb\u3055\u308c\u308c\u3070\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u3082\u505c\u6b62\u3057\u307e\u3059\u3002\u3082\u3061\u308d\u3093\u3001\u9175\u7d20\u91cf\u304c\u4e0d\u8db3\u3057\u3066\u3044\u308b\u3053\u3068\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3067\u304d\u306a\u3044\u5834\u5408\u3082\u7a00\u306b\u3042\u308a\u307e\u3059\u304c\u3001<strong>\u307b\u3068\u3093\u3069\u306e\u5834\u5408\u306f\u904e\u5270\u306a\u9175\u7d20\u304c\u7cfb\u306b\u5b58\u5728\u3059\u308b\u3053\u3068\u304c\u539f\u56e0\u3068\u306a\u3063\u3066\u3044\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u691c\u51fa\u53ef\u80fd\u306a\u30b7\u30b0\u30ca\u30eb\u3092\u5f97\u308b\u306b\u306f\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u8abf\u7bc0\u3057\u307e\u3059\u3002<strong>\u518d\u73fe\u6027\u306e\u3042\u308b\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u65b0\u3057\u3044\u30b2\u30eb\u3092\u7528\u610f\u3057\u3066\u30b5\u30f3\u30d7\u30eb\u91cf\u3092\u6e1b\u3089\u3057\u3066\u30a2\u30d7\u30e9\u30a4\u3059\u308b\u304b\u6297\u4f53\u306e\u81f3\u9069\u6fc3\u5ea6\u3092\u78ba\u8a8d\u3057\u307e\u3059<\/strong>\u3002<\/p>\n<p>\u6297\u4f53\u6fc3\u5ea6\u304c\u81f3\u9069\u5316\u3055\u308c\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u57fa\u8cea\u3068\u306e\u53cd\u5fdc\u3068\u9732\u5149\u30922\u56de\u884c\u3044\u307e\u3059\u30021\u56de\u76ee\u306e\u9732\u5149\u306f\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u305f\u76f4\u5f8c\u306b\u884c\u3044\u30012\u56de\u76ee\u306e\u9732\u5149\u306f\u57fa\u8cea\u3068\u306e\u53cd\u5fdc\u304b\u30891-2\u6642\u9593\u9593\u9694\u3092\u304a\u3044\u3066\u884c\u3044\u307e\u3059\u30022\u56de\u76ee\u306e\u9732\u5149\u304b\u3089\u306f\u6297\u4f53\u6fc3\u5ea6\u306e\u81f3\u9069\u5316\u306b\u5fc5\u8981\u306a\u60c5\u5831\u3092\u5f97\u3089\u308c\u308b\u306f\u305a\u3067\u3059\uff08\u6ce8\uff1b\u81f3\u9069\u5316\u306b\u95a2\u3059\u308b\u64cd\u4f5c\u3092\u53c2\u7167\uff09\u3002<\/p>\n<p>\u307e\u305f\u30011\u56de\u76ee\u306e\u9732\u5149\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u306a\u304b\u3063\u305f\u5834\u5408\u3067\u3082\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u30ea\u30f3\u30b9\u3057\u3066\u6539\u3081\u3066\u65b0\u3057\u3044\u57fa\u8cea\u3068\u306e\u53cd\u5fdc\u3092\u884c\u3046\u3053\u3068\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f1\u56de\u76ee\u306e\u53cd\u5fdc\u3067HRP\u306e\u5927\u90e8\u5206\u304c\u5931\u6d3b\u3057\u305f\u5834\u5408\u3067\u3082\u6d3b\u6027\u3092\u7dad\u6301\u3057\u305fHRP\u304c\u6b8b\u5b58\u3057\u3066\u3044\u308c\u3070\u3001\u65b0\u3057\u304f\u6dfb\u52a0\u3055\u308c\u305f\u57fa\u8cea\u3068\u306e2\u56de\u76ee\u306e\u53cd\u5fdc\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u653e\u51fa\u3055\u308c\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u304b\u3089\u691c\u51fa\u8a66\u85ac\u3092\u9664\u53bb\u3057\u3066\u518d\u30d7\u30ed\u30fc\u30d3\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u7121\u99c4\u306b\u6d88\u8cbb\u305b\u305a\u306b\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3092\u81f3\u9069\u5316\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u3002\u30d6\u30ed\u30c3\u30c8\u9593\u3067\u306e\u4e00\u8cab\u3057\u305f\u7d50\u679c\u3092\u5f97\u308b\u306b\u306f\u3001\u5404\u5b9f\u9a13\u306b\u304a\u3044\u3066\u540c\u4e00\u6761\u4ef6\u3067\u540c\u4e00\u64cd\u4f5c\u3092\u884c\u3046\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n<h3>\u30b7\u30b0\u30ca\u30eb\u304c\u6025\u901f\u306b\u6e1b\u8870\u3059\u308b<\/h3>\n<p>\u3082\u3057\u30b7\u30b0\u30ca\u30eb\u304c\u6025\u6fc0\u306b\u6e1b\u8870\u3057\u305f\u3089\u3001\u305d\u306e\u30a6\u30a8\u30a6\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u691c\u51fa\u7cfb\u306f\u81f3\u9069\u5316\u304c\u5fc5\u8981\u3067\u3059\u3002\u305f\u3060\u3057\u4e00\u6642\u7684\u306b\u3067\u3082\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3042\u308c\u3070\u3001\u7cfb\u306f\u304b\u306a\u308a\u81f3\u9069\u6761\u4ef6\u306b\u8fd1\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<strong>\u8ee2\u5199\u52b9\u7387\u3084\u30b5\u30f3\u30d7\u30eb\u306e\u308f\u305a\u304b\u306a\u5dee\u7570\u3001\u4fdd\u5b58\u4e2d\u3084\u64cd\u4f5c\u4e2d\u306b\u751f\u3058\u305f\u6297\u4f53\u6d3b\u6027\u306e\u308f\u305a\u304b\u306a\u5909\u5316\u304c\u539f\u56e0\u3067\u3059<\/strong>\u3002<\/p>\n<h3>\u65b0\u3057\u3044\u30ed\u30c3\u30c8\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u306a\u3044<\/h3>\n<p>\u57fa\u8cea\u306e\u30dc\u30c8\u30eb\u5909\u66f4\u3084\u88fd\u9020\u30ed\u30c3\u30c8\u5909\u66f4\u3060\u3051\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u306a\u304f\u306a\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3082<strong>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u304c\u5b8c\u5168\u306b\u81f3\u9069\u5316\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u306b\u751f\u3058\u308b\u73fe\u8c61\u3067\u3059<\/strong>\u3002\u57fa\u8cea\u3082\u57fa\u672c\u7684\u306b\u306f\u5909\u52d5\u3057\u307e\u3059\u3002\u591a\u304f\u306e\u57fa\u8cea\u88fd\u9020\u30e1\u30fc\u30ab\u30fc\u3067\u306f\u57fa\u8cea\u306e\u54c1\u8cea\u3092\u53b3\u5bc6\u306b\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3057\u3066\u88fd\u9020\u3057\u3066\u3044\u307e\u3059\u304c\u3001<strong>\u65b0\u3057\u304f\u958b\u5c01\u3057\u305f\u3070\u304b\u308a\u306e\u30dc\u30c8\u30eb\u3067\u306f\u3001\u53e4\u304f\u306a\u3063\u305f\u57fa\u8cea\u3088\u308a\u3082\u611f\u5ea6\u304c\u9ad8\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059<\/strong>\u3002\u5b8c\u5168\u306b\u81f3\u9069\u5316\u3055\u308c\u305f\u691c\u51fa\u7cfb\u3067\u306f\u3001\u3053\u306e\u3088\u3046\u306a\u30dc\u30c8\u30eb\u9593\u3084\u88fd\u9020\u30ed\u30c3\u30c8\u9593\u3067\u306e\u308f\u305a\u304b\u306a\u5dee\u306b\u306f\u6709\u610f\u306e\u5f71\u97ff\u306f\u53d7\u3051\u307e\u305b\u3093\u3002<\/p>\n<p>\u307e\u305f\u3001\u6975\u3081\u3066\u9ad8\u611f\u5ea6\u306e\u691c\u51fa\u304c\u3067\u304d\u308b\u30ed\u30c3\u30c8\u3067\u81f3\u9069\u5316\u3057\u305f\u5b9f\u9a13\u7cfb\u3067\u3082\u3001\u30ed\u30c3\u30c8\u3092\u5909\u3048\u305f\u5834\u5408\u306b\u307e\u3063\u305f\u304f\u691c\u51fa\u3055\u308c\u306a\u304f\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u591a\u304f\u306e\u30e1\u30fc\u30ab\u30fc\u304c\u54c1\u8cea\u4fdd\u8a3c\u3057\u3066\u3044\u308b\u88fd\u54c1\u306e\u611f\u5ea6\u306f\u6700\u4f4e\u691c\u51fa\u611f\u5ea6\u306e\u307f\u3067\u3042\u308a\u3001\u6700\u9ad8\u611f\u5ea6\u306b\u3064\u3044\u3066\u306f\u4fdd\u8a3c\u3092\u3057\u3066\u304a\u3089\u305a\u3001\u304d\u308f\u3081\u3066\u767a\u73fe\u91cf\u306e\u5c11\u306a\u3044\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u304e\u308a\u304e\u308a\u691c\u51fa\u3067\u304d\u305f\u3068\u3057\u3066\u3082\u3001\u5225\u306e\u30ed\u30c3\u30c8\u3067\u306f\u691c\u51fa\u3067\u304d\u306a\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<h3>\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u8336\u8272\u307e\u305f\u306f\u9ec4\u8272\u306e\u30d0\u30f3\u30c9\u304c\u307f\u3048\u308b<\/h3>\n<p>HRP\u306f\u9178\u5316\u3057\u3066\u4e0d\u6d3b\u6027\u306b\u306a\u308b\u3068\u8336\u8272\u306b\u5909\u8272\u3057\u307e\u3059\u3002HRP\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306b\u306f\u4f4e\u3044\u5272\u5408\u3067\u3059\u304c\u9178\u5316\u578b\u306e\u9175\u7d20\u304c\u542b\u307e\u308c\u307e\u3059\u3002\u9178\u5316\u578bHRP\u306e\u5b58\u5728\u7387\u306f\u975e\u5e38\u306b\u4f4e\u304f\u3001\u81f3\u9069\u5316\u3055\u308c\u305f\u7cfb\u3067\u306fHRP\u306e\u8272\u306f\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u3067\u898b\u3048\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002<strong>\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306e\u30d0\u30f3\u30c9\u304c\u9ec4\u8272\uff5e\u8336\u8272\u306b\u898b\u3048\u308b\u306e\u306f\u5927\u91cf\u306eHRP\u304c\u56fa\u5b9a\u3055\u308c\u3066\u3001\u9178\u5316\u3055\u308c\u305f\u4e0d\u6d3b\u6027\u306aHRP\u304c\u5b58\u5728\u3059\u308b\u8a3c\u62e0\u3067\u3059<\/strong>\u3002<\/p>\n<p>\u3055\u3089\u306b\u57fa\u8cea\u306e\u5b58\u5728\u4e0b\u3067\u306f\u904e\u5270\u306aHRP\u304c\u5c40\u5728\u3059\u308b\u7b87\u6240\u306b\u30d5\u30ea\u30fc\u30e9\u30b8\u30ab\u30eb\u304c\u904e\u5270\u306b\u767a\u751f\u3057\u307e\u3059\u3002\u3053\u306e\u30d5\u30ea\u30fc\u30e9\u30b8\u30ab\u30eb\u306fHRP\u3092\u4e0d\u6d3b\u6027\u306b\u3057\u3066\u6297\u4f53\u3001\u6297\u539f\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u3066\u3057\u307e\u3044\u52b9\u679c\u7684\u306a\u518d\u30d7\u30ed\u30fc\u30d6\u3092\u96e3\u3057\u304f\u3057\u307e\u3059\u3002<\/p>\n<h3>\u30d0\u30f3\u30c9\u3084\u30e1\u30f3\u30d6\u30ec\u30f3\u5168\u4f53\u304c\u6697\u5ba4\u3067\u767a\u5149\u3057\u3066\u3044\u308b<\/h3>\n<p>\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u305f\u30e1\u30f3\u30d6\u30ec\u30f3\u304b\u3089\u6697\u5ba4\u5185\u3067\uff08\u30d0\u30f3\u30c9\u30d1\u30bf\u30fc\u30f3\u3084\u30e1\u30f3\u30d6\u30ec\u30f3\u5168\u4f53\u306e\uff09\u767a\u5149\u304c\u8089\u773c\u3067\u78ba\u8a8d\u3055\u308c\u305f\u3089\u3001\u904e\u5270\u306aHRP\u304c\u5b58\u5728\u3059\u308b\u8a3c\u62e0\u3067\u3059\u3002<strong>\u3053\u306e\u73fe\u8c61\u306f\u5c11\u306a\u304f\u3068\u3082\u4e8c\u6b21\u6297\u4f53\u306e\u5e0c\u91c8\u304c\u5fc5\u8981\u3067\u3001\u3082\u3057\u304b\u3057\u305f\u3089\u4e00\u6b21\u6297\u4f53\u306e\u5e0c\u91c8\u3082\u540c\u69d8\u306b\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u3066\u3044\u307e\u3059<\/strong>\u3002HRP\u904e\u5270\u306b\u306f\u591a\u304f\u306e\u8981\u56e0\u304c\u95a2\u4e0e\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30d6\u30ed\u30c3\u30c8\u5168\u4f53\u306e\u767a\u5149\u304c\u78ba\u8a8d\u3055\u308c\u305f\u306e\u3067\u3042\u308c\u3070\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3068\u6d17\u6d44\u306e\u81f3\u9069\u5316\u3082\u5fc5\u8981\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/p>\n<h3>\u30b4\u30fc\u30b9\u30c8\u30d0\u30f3\u30c9\u3084\u767d\u306c\u3051\u30d0\u30f3\u30c9<\/h3>\n<p>\u4e2d\u5fc3\u90e8\u3060\u3051\u767d\u304f\u629c\u3051\u305f\u30d0\u30f3\u30c9\u3084\u30b4\u30fc\u30b9\u30c8\u30d0\u30f3\u30c9\uff08\u9ad8\u3044\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u4e2d\u3067\u30d0\u30f3\u30c9\u5168\u4f53\u304c\u767d\u304f\u629c\u3051\u305f\u30d0\u30f3\u30c9\uff09\u306f\u767d\u304f\u629c\u3051\u305f\u90e8\u5206\u3067\u57fa\u8cea\u304c\u5c40\u6240\u7684\u306b\u6d88\u8cbb\u3055\u308c\u305f\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002<strong>\u30b2\u30eb\u306b\u6dfb\u52a0\u3055\u308c\u305f\u6297\u539f\u91cf\u304c\u904e\u5270\u3067\u3042\u308a\u3001\u4f7f\u7528\u3055\u308c\u305fHRP\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u6fc3\u5ea6\u304c\u9ad8\u3044\u3053\u3068\u304c\u6700\u3082\u5178\u578b\u7684\u306a\u539f\u56e0\u3068\u3055\u308c\u307e\u3059<\/strong>\u3002<\/p>\n<h3>\u9ad8\u3044\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9<\/h3>\n<p><strong>\u4e0d\u5341\u5206\u306a\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3001\u6297\u4f53\u306e\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3068\u306e\u4ea4\u53c9\u53cd\u5fdc\u3001\u904e\u5270\u306b\u4f7f\u7528\u3055\u308c\u305f\u9175\u7d20\u6a19\u8b58\u7269\u306e\u3069\u308c\u3082\u304c\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u4e0a\u6607\u306e\u539f\u56e0\u3068\u306a\u308a\u307e\u3059<\/strong>\u3002\u7279\u5b9a\u306e\u57fa\u8cea\u81ea\u4f53\u304c\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u539f\u56e0\u3068\u306a\u308a\u3046\u308b\u3068\u8003\u3048\u308b\u7814\u7a76\u8005\u3084\u3001\u57fa\u8cea\u81ea\u4f53\u304c\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u4e0a\u6607\u3055\u305b\u308b\u3068\u8003\u3048\u3066\u3044\u308b\u7814\u7a76\u8005\u3082\u3044\u307e\u3059\u304c\u3001\u9175\u7d20\u306e\u89e6\u5a92\u4f5c\u7528\u304c\u306a\u3051\u308c\u3070\u57fa\u8cea\u304c\u30b7\u30b0\u30ca\u30eb\u3092\u767a\u751f\u3055\u305b\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u4ee5\u524d\u306b\u4f7f\u7528\u3057\u3066\u3044\u305f\u57fa\u8cea\u3088\u308a\u611f\u5ea6\u304c\u306f\u308b\u304b\u306b\u9ad8\u3044\u57fa\u8cea\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u9ad8\u611f\u5ea6\u306a\u57fa\u8cea\u3092\u88dc\u3046\u3060\u3051\u306b\u5341\u5206\u306a\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u306e\u5909\u66f4\u304c\u884c\u308f\u308c\u3066\u3044\u306a\u3044\u3068\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u4e0a\u6607\u3057\u307e\u3059\u3002\u6700\u9069\u306a\u6fc3\u5ea6\u306e\u6297\u4f53\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u6297\u539f\u7279\u7570\u7684\u306a\u7d50\u5408\u304c\u4fc3\u9032\u3055\u308c\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u306f\u6291\u5236\u3055\u308c\u307e\u3059\u3002<\/p>\n<h2>\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3068\u6297\u4f53\u5265\u96e2\u306b\u95a2\u3059\u308b\u4e00\u822c\u30d7\u30ed\u30c8\u30b3\u30eb<\/h2>\n<p>\u3053\u306e\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u306f\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u304b\u3089\u306e\u6297\u4f53\u5265\u96e2\u3001\u81f3\u9069\u5316\u3001\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306b\u3064\u3044\u3066\u4e00\u822c\u7684\u306a\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u3053\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u306f\u4e00\u822c\u7684\u306a\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u30d7\u30ed\u30c8\u30b3\u30eb\u3067\u3042\u308a\u3001\u3055\u307e\u3056\u307e\u306a\u6761\u4ef6\u306b\u3064\u3044\u3066\u7db2\u7f85\u7684\u306b\u8a18\u8ff0\u3057\u3066\u3044\u307e\u305b\u3093\u304c\u3001\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u5b9f\u969b\u306e\u64cd\u4f5c\u6982\u8981\u306f\u7406\u89e3\u3067\u304d\u307e\u3059\u3002<\/p>\n<p>\u5f0a\u793e\u88fd\u54c1\u306b\u306f\u30d7\u30ec\u30ad\u30e3\u30b9\u30c8\u30b2\u30eb\u3001\u96fb\u6c17\u6cf3\u52d5\u30d0\u30c3\u30d5\u30a1\u30fc\u3001\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u3001\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3001\u4e00\u6b21\u6297\u4f53\u3001\u4e8c\u6b21\u6297\u4f53\u3001\u5316\u5b66\u767a\u5149\u57fa\u8cea\u3001\u30d5\u30a3\u30eb\u30e0\u306a\u3069\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306b\u5fc5\u8981\u306a\u8a66\u85ac\u304c\u63c3\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n<h3>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u30fb\u30d7\u30ed\u30c8\u30b3\u30eb<\/h3>\n<ol>\n<li>\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u30b2\u30eb\u96fb\u6c17\u6cf3\u52d5\u3067\u5206\u96e2\u3057\u307e\u3059\u3002<\/li>\n<li>\u8ee2\u5199\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u8abf\u88fd: 400ml\u306e\u30c8\u30ea\u30b9\u30b0\u30ea\u30b7\u30f3\u8ee2\u5199\u30d0\u30c3\u30d5\u30a1\u30fc\u306b100ml\u30e1\u30bf\u30ce\u30fc\u30eb\u3092\u6dfb\u52a0\u3057\u307e\u3059\u3002(25 mM Tris, 192 mM glycine, pH 8.0, 20% methanol). \u8ee2\u5199\u30d0\u30c3\u30d5\u30a1\u30fc\u306f4\u2103\u3067\u4f7f\u7528\u30fb\u4fdd\u5b58\u3057\u307e\u3059\u3002<\/li>\n<li>\u30bf\u30f3\u30af\u5f0f\u306f\u56f33\u306e\u3088\u3046\u306b\u30b2\u30eb\u3092\u30b5\u30f3\u30c9\u30a4\u30c3\u30c1\u72b6\u306b\u30bb\u30c3\u30c8\u3057\u307e\u3059\u3002\u30bb\u30df\u30c9\u30e9\u30a4\u5f0f\u3082\u540c\u69d8\u306b\u6b63\u6975\u3068\u8ca0\u6975\u306e\u9593\u306b\u30b2\u30eb\u3092\u30bb\u30c3\u30c8\u3057\u307e\u3059\u3002<\/li>\n<li>\u30b2\u30eb\u304b\u3089\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u8ee2\u5199\u3057\u307e\u3059\u3002\u30df\u30cb\u30b2\u30eb\u7528\u306e\u30bf\u30f3\u30af\u5f0f\u8ee2\u5199\u88c5\u7f6e\u3067\u306f\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u6e29\u5ea6\u30924\u2103\u306b\u7dad\u6301\u3057\u306a\u304c\u308940V\u306790\u5206\u9593\u3001\u30bb\u30df\u30c9\u30e9\u30a4\u5f0f\u3067\u306f15V\u306790\u5206\u9593\u306a\u3069\u3001\u8ee2\u5199\u88c5\u7f6e\u306e\u63a8\u5968\u6761\u4ef6\u306b\u5f93\u3044\u307e\u3059\u3002<\/li>\n<li>\u8ee2\u5199\u5f8c\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u53d6\u308a\u51fa\u3057\u3001\u5ba4\u6e29\u3067\u652a\u62cc\u3057\u306a\u304c\u308920-60\u5206\u9593\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u4e2d\u3067\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u975e\u7279\u7570\u7684\u7d50\u5408\u30b5\u30a4\u30c8\u3092\u30d6\u30ed\u30c3\u30af\u3057\u307e\u3059\u3002<\/li>\n<li>\u6700\u7d42\u6fc3\u5ea610%\u3067\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u6dfb\u52a0\u3057\u305f\u4e00\u6b21\u6297\u4f53\u6eb6\u6db2\u4e2d\uff08\u88682\uff09\u3068\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u652a\u62cc\u3057\u306a\u304c\u3089\u5ba4\u6e29\u30671\u6642\u9593\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30c8\u3057\u307e\u3059\u30022-8\u2103\u3067\u30aa\u30fc\u30d0\u30fc\u30ca\u30a4\u30c8\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u3082\u53ef\u80fd\u3067\u3059\u3002<\/li>\n<li>0.05% Tween-20\u3092\u542b\u3080TBS\u3084PBS\u306a\u3069\u306e\u751f\u7406\u7684\u6761\u4ef6\u306e\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u3067\u30e1\u30f3\u30d6\u30ec\u30f3\u30923\u56de\uff08\u54045\u5206\u9593\uff09\u6d17\u6d44\u3057\u307e\u3059\u3002\u9175\u7d20\u6a19\u8b58\u4e00\u6b21\u6297\u4f53\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u30b9\u30c6\u30c3\u30d710\u306b\u9032\u307f\u307e\u3059\u3002<\/li>\n<li>\u6700\u7d42\u6fc3\u5ea610%\u3067\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u6dfb\u52a0\u3057\u305f\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\uff08\u88682\uff09\u3068\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u652a\u62cc\u3057\u306a\u304c\u3089\u5ba4\u6e29\u30671\u6642\u9593\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u3057\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u30675\u56de\uff08\u54045\u5206\u9593\uff09\u6d17\u6d44\u3057\u3066\u672a\u53cd\u5fdc\u306a\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3092\u9664\u53bb\u3057\u307e\u3059\u3002\u3053\u3053\u3067\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u5341\u5206\u306b\u6d17\u6d44\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/li>\n<li>\u57fa\u8cea\u3092\u8abf\u88fd\u3057\u307e\u3059\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u304c\u5b8c\u5168\u306b\u6d78\u308b\u7a0b\u5ea6\u306e\u5341\u5206\u91cf\uff080.125 ml\/cm2\uff09\u3092\u7528\u3044\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u51e6\u7406\u3057\u307e\u3059\u3002<\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/32106?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce Western Blotting Substrate<\/a>\u306e\u5834\u5408\u306f1\u5206\u9593\u3001SuperSignal\u306e\u5834\u5408\u306f5\u5206\u9593\u3001\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u57fa\u8cea\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30d7\u30ed\u30c6\u30af\u30bf\u30fc\u306b\u30bb\u30c3\u30c8\u3057\u307e\u3059\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u30fb\u30d7\u30ed\u30c6\u30af\u30bf\u30fc\u304c\u304a\u3059\u3059\u3081\u3067\u3059\u304c\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30e9\u30c3\u30d7\u3067\u3082\u4ee3\u7528\u3067\u304d\u307e\u3059\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u3068\u30d7\u30ed\u30c6\u30af\u30bf\u30fc\u306e\u9593\u306e\u6c17\u6ce1\u3092\u9664\u53bb\u3057\u307e\u3059\u3002<\/li>\n<li>\u30d5\u30a3\u30eb\u30e0\u307e\u305f\u306fCCD\u30ab\u30e1\u30e9\u3067\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u3092\u753b\u50cf\u5316\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n<div id=\"attachment_1030\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-fig3.jpg\" rel=\"attachment wp-att-1030\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-1030\" class=\"size-full wp-image-1030\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-fig3.jpg\" alt=\"chemiluminescent-westernblotting-fig3\" width=\"500\" height=\"306\" \/><\/a><p id=\"caption-attachment-1030\" class=\"wp-caption-text\">\u56f33 \u8ee2\u5199\u88c5\u7f6e<\/p><\/div>\n<table>\n<caption>\u88682 Pierce \u5316\u5b66\u767a\u5149\u57fa\u8cea\u3067\u306e\u4e00\u6b21\u6297\u4f53\u6fc3\u5ea6\u3068\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u6fc3\u5ea6<\/caption>\n<tbody>\n<tr>\n<td>\u57fa\u8cea<\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/32106?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Pierce Western Blotting Substrate<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/34080?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">SuperSignal West Pico<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/34075?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">SuperSignal West Dura<\/a><\/td>\n<td><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/34095?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">SuperSignal West Femto<\/a><\/td>\n<\/tr>\n<tr>\n<td>\u4e00\u6b21\u6297\u4f53\u6fc3\u5ea6<\/td>\n<td>0.2 &#8211; 10 \u03bcg\/ml<\/td>\n<td>0.2 &#8211; 1 \u03bcg\/ml<\/td>\n<td>0.02 &#8211; 1 \u03bcg\/ml<\/td>\n<td>0.01 &#8211; 0.2 \u03bcg\/ml<\/td>\n<\/tr>\n<tr>\n<td>\u4e8c\u6b21\u6297\u4f53\u6fc3\u5ea6<\/td>\n<td>67 &#8211; 1,000 ng\/ml<\/td>\n<td>10 &#8211; 50 ng\/ml<\/td>\n<td>4 &#8211; 20 ng\/ml<\/td>\n<td>2 &#8211; 10 ng\/ml<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>\u6297\u4f53\u5265\u96e2\u30d7\u30ed\u30c8\u30b3\u30eb<\/h3>\n<ol>\n<li>\u6297\u4f53\u5265\u96e2\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u8abf\u88fd\u3057\u307e\u3059\u3002\u4e0b\u8a18\u306e4\u3064\u306e\u6297\u4f53\u5265\u96e2\u30d0\u30c3\u30d5\u30a1\u30fc\u304b\u3089\u3072\u3068\u3064\u3092\u9078\u629e\u3057\u307e\u3059\u3002\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/21059?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Restore\u2122 Western Blot Stripping Buffer<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/46428?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">Restore\u2122 Plus Western Blot Stripping Buffer<\/a><\/li>\n<li>0.1 M glycine\u2022HCl (pH 2.5-3.0)<\/li>\n<li>50 mM Tris\u2022HCl (pH 7), 2% sodium dodecyl sulfate (SDS), 50 mM dithiothreitol (DTT)<\/li>\n<\/ul>\n<\/li>\n<li>\u6297\u4f53\u3092\u5265\u96e2\u3059\u308b\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6297\u4f53\u5265\u96e2\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u6d78\u3057\u307e\u3059\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u304c\u6d78\u308b\u7a0b\u5ea6\u306e\u5341\u5206\u91cf\uff088\u00d710 cm\u30e1\u30f3\u30d6\u30ec\u30f3\u3067\u306f\u7d0420ml\uff09\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002<\/li>\n<li>\u5ba4\u6e29\u30675-15\u5206\u9593\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002\u6700\u9069\u306a\u7d50\u679c\u3092\u5f97\u308b\u306b\u306f\u53cd\u5fdc\u6642\u9593\u304a\u3088\u3073\u53cd\u5fdc\u6e29\u5ea6\u306e\u81f3\u9069\u5316\u304c\u5fc5\u8981\u3067\u3059\u3002\u6297\u4f53\u306e\u89aa\u548c\u6027\u306b\u3088\u3063\u3066\u306f37\u2103\u3067\u306e15\u5206\u9593\u4ee5\u4e0a\u306e\u53cd\u5fdc\u304c\u5fc5\u8981\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u30d0\u30c3\u30d5\u30a1\u30fc C)\u3092\u7528\u3044\u308b\u5834\u5408\u300170\u2103\u3067\u306e30\u5206\u9593\u306e\u53cd\u5fdc\u304c\u5fc5\u8981\u3067\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u5265\u96e2\u30d0\u30c3\u30d5\u30a1\u30fc\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc(0.05% Tween-20\u3092\u542b\u3080PBS\/TBS\u307e\u305f\u306f\u751f\u7406\u7684\u6761\u4ef6\u306e\u30d0\u30c3\u30d5\u30a1\u30fc)\u3067\u6d17\u6d44\u3057\u307e\u3059\u3002<\/li>\n<li>\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3068\u4e00\u6b21\u6297\u4f53\u304c\u5b8c\u5168\u306b\u9664\u53bb\u3055\u308c\u305f\u3053\u3068\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u4ee5\u4e0b\u306e\u8a66\u9a13\u3092\u884c\u3044\u307e\u3059\u3002\u3044\u305a\u308c\u304b\u306e\u8a66\u9a13\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u305f\u5834\u5408\u3001\u3055\u3089\u306b5-15\u5206\u9593\u306e\u3042\u3044\u3060\u6e29\u5ea6\u309237\u2103\u307e\u3067\u4e0a\u6607\u3055\u305b\u3001\u64cd\u4f5c2-4\u3092\u7e70\u308a\u8fd4\u3057\u307e\u3059\u3002\u6297\u539f\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u305a\u6297\u4f53\u3092\u5b8c\u5168\u306b\u9664\u53bb\u3067\u304d\u308b\u53cd\u5fdc\u6642\u9593\u3068\u53cd\u5fdc\u6e29\u5ea6\u306b\u81f3\u9069\u5316\u3057\u307e\u3059\u3002\n<ul>\n<li>\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u304c\u5b8c\u5168\u306b\u30e1\u30f3\u30d6\u30ec\u30f3\u304b\u3089\u9664\u53bb\u3055\u308c\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u3001\u6297\u4f53\u5265\u96e2\u5f8c\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u3066\u30d5\u30a3\u30eb\u30e0\u306a\u3069\u3067\u753b\u50cf\u5316\u3057\u307e\u3059\u3002\u3082\u3057\u30015\u5206\u9593\u306e\u9732\u5149\u3067\u30d5\u30a3\u30eb\u30e0\u306b\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u306a\u3051\u308c\u3070\u3001\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306f\u5b8c\u5168\u306b\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u304b\u3089\u9664\u53bb\u3055\u308c\u3066\u3044\u308b\u306f\u305a\u3067\u3059\u3002<\/li>\n<li>\u4e00\u6642\u6297\u4f53\u304c\u5b8c\u5168\u306b\u30e1\u30f3\u30d6\u30ec\u30f3\u304b\u3089\u9664\u53bb\u3055\u308c\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3059\u308b\u306b\u306f\u3001\u6297\u4f53\u5265\u96e2\u5f8c\u306e\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3068\u53cd\u5fdc\u3055\u305b\u305f\u5f8c\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u3067\u6d17\u6d44\u3057\u307e\u3059\u3002\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u3066\u30d5\u30a3\u30eb\u30e0\u306a\u3069\u3067\u753b\u50cf\u5316\u3057\u307e\u3059\u3002\u3082\u3057\u30015\u5206\u9593\u306e\u9732\u5149\u3067\u30d5\u30a3\u30eb\u30e0\u306b\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u306a\u3051\u308c\u3070\u3001\u4e00\u6b21\u6297\u4f53\u306f\u5b8c\u5168\u306b\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u304b\u3089\u9664\u53bb\u3055\u308c\u3066\u3044\u308b\u306f\u305a\u3067\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n<li>\u6297\u4f53\u304c\u30e1\u30f3\u30d6\u30ec\u30f3\u304b\u3089\u9069\u5207\u306b\u5265\u96e2\u3055\u308c\u308b\u6761\u4ef6\u3092\u78ba\u8a8d\u3057\u305f\u3089\u3001\u518d\u30d7\u30ed\u30fc\u30d3\u30f3\u30b0\u3092\u958b\u59cb\u3057\u307e\u3059\u3002\u4e00\u822c\u306b\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u6297\u4f53\u5265\u96e2\u304a\u3088\u3073\u518d\u30d7\u30ed\u30fc\u30d3\u30f3\u30b0\u306f\u6570\u56de\u307e\u3067\u53ef\u80fd\u3067\u3059\u304c\u3001\u518d\u30d7\u30ed\u30fc\u30d3\u30f3\u30b0\u3067\u306f\u9577\u6642\u9593\u306e\u30a4\u30f3\u30ad\u30e5\u30d9\u30fc\u30b7\u30e7\u30f3\u3084\u9ad8\u611f\u5ea6\u306a\u57fa\u8cea\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n<\/ol>\n<h2>\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u6761\u4ef6\u81f3\u9069\u5316\u306b\u95a2\u3059\u308b\u64cd\u4f5c<\/h2>\n<h3>\u6297\u539f\u6fc3\u5ea6\u306e\u81f3\u9069\u5316<\/h3>\n<ol>\n<li>SDS-PAGE\u30b5\u30f3\u30d7\u30eb\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u7528\u3044\u3066\u30bf\u30f3\u30d1\u30af\u8cea\u8a66\u6599\u3092\u7570\u306a\u308b\u6fc3\u5ea6\u3067\u8abf\u88fd\u3057\u307e\u3059\u3002\u5e83\u7bc4\u56f2\u306e\u6fc3\u5ea6\u3092\u8a66\u9a13\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u304c\u3001\u304b\u306a\u3089\u305a\u4f7f\u7528\u3059\u308b\u57fa\u8cea\u306e\u691c\u51fa\u4e0b\u9650\u4ee5\u4e0a\u306e\u6fc3\u5ea6\u3067\u8abf\u88fd\u3057\u307e\u3059\u3002<\/li>\n<li>\u5404\u6fc3\u5ea6\u306e\u8a66\u6599\u3092\u7b49\u91cf\u3067\u30b2\u30eb\u306b\u30a2\u30d7\u30e9\u30a4\u3001\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308a\u5206\u96e2\u3057\u305f\u5f8c\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3057\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6a19\u6e96\u7684\u306a\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u3088\u308a\u30d6\u30ed\u30c3\u30af\u3001\u4e00\u6b21\u6297\u4f53\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u305f\u5f8c\u3001\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u307e\u3059\u3002\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306e\u81f3\u9069\u5316\u6fc3\u5ea6\u304c\u6c7a\u5b9a\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u306b\u306f\u4f7f\u7528\u3059\u308b\u57fa\u8cea\u306b\u5fdc\u3058\u305f\u63a8\u5968\u6fc3\u5ea6\u57df\u306e\u4e2d\u9593\u6fc3\u5ea6\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6d17\u6d44\u3057\u3066\u57fa\u8cea\u3092\u6dfb\u52a0\u3057\u307e\u3059\u3002\u9069\u5f53\u306a\u65b9\u6cd5\u3067\u30b7\u30b0\u30ca\u30eb\u3092\u753b\u50cf\u5316\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n<h3>\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u306e\u81f3\u9069\u5316<\/h3>\n<ol>\n<li>\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308a\u30bf\u30f3\u30d1\u30af\u8cea\u8a66\u6599\u3092\u5206\u96e2\u3057\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3059\u308b\u304b\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u30c9\u30c3\u30c8\u30d6\u30ed\u30c3\u30c8\u3057\u307e\u3059\u3002<\/li>\n<li>\u8a66\u9a13\u3059\u308b\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u306e\u6761\u4ef6\u691c\u8a0e\u6570\u306b\u5fdc\u3058\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u30b9\u30c8\u30ea\u30c3\u30d7\u72b6\u306b\u30ab\u30c3\u30c8\u3057\u307e\u3059\u3002\u5404\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u6761\u4ef6\u306b\u3064\u3044\u3066\u4ee5\u4e0b\u306e\u7d44\u307f\u5408\u308f\u305b\u3067\u884c\u3044\u307e\u3059\u3002\n<ul>\n<li>\u30d6\u30ed\u30c3\u30ab\u30fc + \u4e00\u6b21\u6297\u4f53 + \u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53+ \u57fa\u8cea<\/li>\n<li>\u30d6\u30ed\u30c3\u30ab\u30fc + \u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53 + \u57fa\u8cea<\/li>\n<li>\u30d6\u30ed\u30c3\u30ab\u30fc + \u57fa\u8cea<\/li>\n<\/ul>\n<\/li>\n<li>\u5404\u30b9\u30c8\u30ea\u30c3\u30d7\u3092\u5341\u5206\u91cf\u306e\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u7528\u3044\u652a\u62cc\u3057\u306a\u304c\u3089\u5ba4\u6e29\u30671\u6642\u9593\u30d6\u30ed\u30c3\u30af\u3057\u307e\u3059\u3002<\/li>\n<li>\u6700\u7d42\u6fc3\u5ea610%\u3067\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u6dfb\u52a0\u3057\u305f\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\/\u307e\u305f\u306f\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3092\u8a66\u9a13\u3059\u308b\u30b9\u30c8\u30ea\u30c3\u30d7\u306b\u5fdc\u3058\u3066\u6dfb\u52a0\u3057\u307e\u3059\u3002\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306e\u81f3\u9069\u5316\u6fc3\u5ea6\u304c\u6c7a\u5b9a\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u306b\u306f\u4f7f\u7528\u3059\u308b\u57fa\u8cea\u306b\u5fdc\u3058\u305f\u63a8\u5968\u6fc3\u5ea6\u57df\u306e\u4e2d\u9593\u6fc3\u5ea6\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6d17\u6d44\u3057\u3066\u57fa\u8cea\u3092\u6dfb\u52a0\u3057\u307e\u3059\u3002\u9069\u5f53\u306a\u65b9\u6cd5\u3067\u30b7\u30b0\u30ca\u30eb\u3092\u753b\u50cf\u5316\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n<h3>\u4e00\u6b21\u6297\u4f53\u6fc3\u5ea6\u306e\u81f3\u9069\u5316<\/h3>\n<ol>\n<li>\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308a\u30bf\u30f3\u30d1\u30af\u8cea\u8a66\u6599\u3092\u5206\u96e2\u3057\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3059\u308b\u304b\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u30c9\u30c3\u30c8\u30d6\u30ed\u30c3\u30c8\u3057\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u6a19\u6e96\u7684\u306a\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u306b\u3088\u308a\u30d6\u30ed\u30c3\u30af\u3057\u307e\u3059\u3002\u8a66\u9a13\u3059\u308b\u4e00\u6b21\u6297\u4f53\u6fc3\u5ea6\u306e\u691c\u8a0e\u6761\u4ef6\u6570\u306b\u5fdc\u3058\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u30b9\u30c8\u30ea\u30c3\u30d7\u72b6\u306b\u30ab\u30c3\u30c8\u3057\u307e\u3059\u3002<\/li>\n<li>\u6700\u7d42\u6fc3\u5ea610%\u306e\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u542b\u3080\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u7528\u3044\u3066\u4e00\u6b21\u6297\u4f53\u306e\u5e0c\u91c8\u7cfb\u5217\u3092\u8abf\u88fd\u3001\u30b9\u30c8\u30ea\u30c3\u30d7\u306b\u6dfb\u52a0\u3057\u307e\u3059\u3002\u5ba4\u6e29\u30671\u6642\u9593\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002<\/li>\n<li>\u30b9\u30c8\u30ea\u30c3\u30d7\u3092\u6d17\u6d44\u3057\u3066\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3068\u5ba4\u6e29\u3067\u4e00\u6642\u9593\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002\u518d\u5ea6\u30b9\u30c8\u30ea\u30c3\u30d7\u3092\u6d17\u6d44\u3057\u3066\u5f8c\u3001\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u3066\u30b7\u30b0\u30ca\u30eb\u3092\u30d5\u30a3\u30eb\u30e0\u307e\u305f\u306fCCD\u30ab\u30e1\u30e9\u3067\u691c\u51fa\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n<h3>\u30e1\u30f3\u30d6\u30ec\u30f3\u6d17\u6d44\u6761\u4ef6\u306e\u81f3\u9069\u5316<\/h3>\n<ol>\n<li>0.05% Tween-20\u3092\u542b\u3080PBS, TBS, \u307e\u305f\u306f\u751f\u7406\u7684\u6761\u4ef6\u306e\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u3068\u3057\u3066\u7528\u3044\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u7a4f\u3084\u304b\u306b\u652a\u62cc\u3057\u306a\u304c\u30895\u5206\u9593\u6d17\u6d44\u3057\u307e\u3059\u3002\u4e00\u6b21\u6297\u4f53\u3068\u306e\u53cd\u5fdc\u306e\u5f8c\u306e\u6d17\u6d44\u306f\u5c11\u306a\u304f\u3068\u30823\u56de\u4ee5\u4e0a\u884c\u3044\u3001\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3068\u306e\u53cd\u5fdc\u306e\u5f8c\u306f\u5c11\u306a\u304f\u3068\u30825\u56de\u4ee5\u4e0a\u6d17\u6d44\u3057\u307e\u3059\u3002<\/li>\n<li>\u30b7\u30b0\u30ca\u30eb\u306e\u691c\u51fa\u3067\u975e\u7279\u7570\u7684\u306a\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u78ba\u8a8d\u3055\u308c\u305f\u5834\u5408\u3001\u4f7f\u7528\u3059\u308b\u6d17\u6d44\u30d0\u30c3\u30d5\u30a1\u30fc\u91cf\u3092\u5897\u3084\u3059\u304b\u3001\u6d17\u6d44\u56de\u6570\u307e\u305f\u306f\u6d17\u6d44\u6642\u9593\u3092\u5897\u3084\u3057\u307e\u3059\u3002\u6539\u5584\u304c\u8a8d\u3081\u3089\u308c\u306a\u3044\u5834\u5408\u3001\u539f\u56e0\u306f\u6d17\u6d44\u6761\u4ef6\u4ee5\u5916\u306b\u3042\u308a\u307e\u3059\u3002<\/li>\n<\/ol>\n<h3>\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\uff08\u9175\u7d20\u6a19\u8b58\u7269\uff09\u306e\u81f3\u9069\u5316<\/h3>\n<p>\u65b0\u3057\u3044\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u7cfb\u3067\u81f3\u9069\u6fc3\u5ea6\u3092\u6c42\u3081\u308b\u969b\u3001\u7c21\u5358\u306a\u5b9f\u9a13\u3067\u5909\u52d5\u7684\u306a\u30b7\u30b0\u30ca\u30eb\u306b\u4f34\u3046\u554f\u984c\u3092\u6539\u5584\u3067\u304d\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<ol>\n<li>\u7b49\u91cf\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u8a66\u6599\u30923\u30ec\u30fc\u30f3\u4ee5\u4e0a\u30b2\u30eb\u306b\u30a2\u30d7\u30e9\u30a4\u3057\u307e\u3059\u3002<\/li>\n<li>\u30bf\u30f3\u30d1\u30af\u8cea\u8a66\u6599\u3092\u96fb\u6c17\u6cf3\u52d5\u3067\u5206\u96e2\u3057\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3057\u307e\u3059\u3002\u975e\u7279\u7570\u7684\u30b5\u30a4\u30c8\u3092\u30d6\u30ed\u30c3\u30af\u3059\u308b\u305f\u3081\u306b\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3092\u884c\u3063\u305f\u5f8c\u3001\u4e00\u6b21\u6297\u4f53\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u307e\u3059\u3002<\/li>\n<li>\u6d17\u6d44\u5f8c\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u30b9\u30c8\u30ea\u30c3\u30d7\u72b6\u306b\u30ab\u30c3\u30c8\u3057\u307e\u3059\u3002<\/li>\n<li>\u8a66\u9a13\u3059\u308b\u7570\u306a\u308b\u6fc3\u5ea6\u306e\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/34080?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener noreferrer\">SuperSignal West Pico Substrate<\/a>\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u30011:4000, 1:6000, 1:8000\u306e\u5e0c\u91c8\u500d\u7387(1 mg\/ml\u30b9\u30c8\u30c3\u30af\u304b\u3089\u306e\u5e0c\u91c8\u500d\u7387)\u3067\u8a66\u9a13\u3057\u307e\u3059\u3002\u5ba4\u6e29\u3067\u652a\u62cc\u3057\u306a\u304c\u30891\u6642\u9593\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002<\/li>\n<li>\u30b9\u30c8\u30ea\u30c3\u30d7\u3092\u6d17\u6d44\u3001\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u305f\u5f8c\u3001\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u3092\u30d5\u30a3\u30eb\u30e0\u7b49\u306b\u9732\u5149\u3057\u307e\u3059\u3002<\/li>\n<li>1-2\u6642\u9593\u5f85\u3063\u3066\u3001\u518d\u3073\u767a\u5149\u30b7\u30b0\u30ca\u30eb\u3092\u30d5\u30a3\u30eb\u30e0\u7b49\u306b\u9732\u5149\u3057\u307e\u3059\u3002<\/li>\n<li>\u7d50\u679c\u3092\u8a55\u4fa1\u3057\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u30012\u56de\u76ee\u306e\u9732\u5149\u306b\u304a\u3044\u30661:8000\u5e0c\u91c8\u3067\u30b7\u30b0\u30ca\u30eb\u304c\u5f97\u3089\u308c\u4ed6\u306e\u5e0c\u91c8\u500d\u7387\u3067\u306f\u30b7\u30b0\u30ca\u30eb\u304c\u691c\u51fa\u3055\u308c\u306a\u304b\u3063\u305f\u5834\u5408\u30011:8000\u5e0c\u91c8\u304c\u6700\u3082\u81f3\u9069\u6761\u4ef6\u306b\u8fd1\u3044\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u30011:4000\u5e0c\u91c8\u3067\u5f37\u3044\u30b7\u30b0\u30ca\u30eb\u304c\u5f97\u3089\u308c\u4ed6\u306e\u5e0c\u91c8\u500d\u7387\u3067\u306f\u30b7\u30b0\u30ca\u30eb\u304c\u5f97\u3089\u308c\u306a\u3044\u5834\u5408\u3001\u3088\u308a\u5e0c\u91c8\u500d\u7387\u306e\u4f4e\u3044\uff08\u9ad8\u6fc3\u5ea6\u306a\uff09\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u6fc3\u5ea6\u304c\u81f3\u9069\u6761\u4ef6\u306b\u8fd1\u3044\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/li>\n<\/ol>\n<h3>\u691c\u51fa\u6cd5\u306e\u81f3\u9069\u5316<\/h3>\n<ol>\n<li>\u96fb\u6c17\u6cf3\u52d5\u306b\u3088\u308a\u30bf\u30f3\u30d1\u30af\u8cea\u8a66\u6599\u3092\u5206\u96e2\u3057\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3059\u308b\u304b\u3001\u30e1\u30f3\u30d6\u30ec\u30f3\u4e0a\u306b\u30c9\u30c3\u30c8\u30d6\u30ed\u30c3\u30c8\u3057\u307e\u3059\u3002<\/li>\n<li>\u30e1\u30f3\u30d6\u30ec\u30f3\u306e\u975e\u7279\u7570\u7684\u30b5\u30a4\u30c8\u3092\u30d6\u30ed\u30c3\u30af\u3059\u308b\u305f\u3081\u306b\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u3092\u884c\u3063\u305f\u5f8c\u3001\u6700\u7d42\u6fc3\u5ea610%\u306e\u30d6\u30ed\u30c3\u30ad\u30f3\u30b0\u30d0\u30c3\u30d5\u30a1\u30fc\u3092\u542b\u3080\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u307e\u3059\u3002<\/li>\n<li>\u4e00\u6b21\u6297\u4f53\u304a\u3088\u3073\u9175\u7d20\u6a19\u8b58\u4e8c\u6b21\u6297\u4f53\u306e\u81f3\u9069\u5316\u6fc3\u5ea6\u304c\u6c7a\u5b9a\u3055\u308c\u3066\u3044\u306a\u3044\u5834\u5408\u306b\u306f\u4f7f\u7528\u3059\u308b\u57fa\u8cea\u306b\u5fdc\u3058\u305f\u63a8\u5968\u6fc3\u5ea6\u57df\u306e\u4e2d\u9593\u6fc3\u5ea6\u3067\u30d7\u30ed\u30fc\u30d6\u3057\u307e\u3059\u3002<\/li>\n<li>\u8a66\u9a13\u3059\u308b\u57fa\u8cea\u306e\u691c\u51fa\u6761\u4ef6\u6570\u306b\u5fdc\u3058\u3066\u30e1\u30f3\u30d6\u30ec\u30f3\u3092\u30b9\u30c8\u30ea\u30c3\u30d7\u72b6\u306b\u30ab\u30c3\u30c8\u3057\u307e\u3059\u3002\u8a66\u9a13\u3059\u308b\u57fa\u8cea\u3092\u8abf\u88fd\u3057\u307e\u3059\u3002<\/li>\n<li>\u88fd\u9020\u5143\u63a8\u5968\u6761\u4ef6\u3067\u30b9\u30c8\u30ea\u30c3\u30d7\u3092\u57fa\u8cea\u3068\u53cd\u5fdc\u3055\u305b\u307e\u3059\u3002<\/li>\n<li>\u30b9\u30c8\u30ea\u30c3\u30d7\u3092\u30d4\u30f3\u30bb\u30c3\u30c8\u3067\u57fa\u8cea\u304b\u3089\u53d6\u308a\u51fa\u3057\u3001\u30da\u30fc\u30d1\u30fc\u30bf\u30aa\u30eb\u306e\u4e0a\u3067\u30bf\u30c3\u30d7\u3001\u4f59\u5270\u306a\u57fa\u8cea\u3092\u9664\u53bb\u3057\u307e\u3059\u3002<\/li>\n<li>\u30b9\u30c8\u30ea\u30c3\u30d7\u3092\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30ab\u30d0\u30fc\u306b\u30bb\u30c3\u30c8\u3057\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u6642\u9593\u3067\u9732\u5149\u3057\u307e\u3059\u3002\u30d0\u30c3\u30af\u30b0\u30e9\u30f3\u30c9\u306e\u4f4e\u3044\u9732\u5149\u6642\u9593\u3092\u9078\u629e\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n<p>\u6b21\u56de\u306f\u691c\u51fa\u611f\u5ea6\u3092\u3042\u3052\u305f\u3044\u5834\u5408\u306e\u30dd\u30a4\u30f3\u30c8\u306b\u3064\u3044\u3066\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n<h2>\u53c2\u8003\u6587\u732e<\/h2>\n<ul>\n<li>Bers, G. and Garfin, D. (1985). Protein and nucleic acid blotting and immunobiochemical detection. BioTechniques 3:276-88.<\/li>\n<li>Bjerrum, O.J. and Heegaard, N.H.H. (1988). Handbook of Immunoblotting of Proteins. Volume 1. Technical Descriptions. CRC Press, Boca Raton.<\/li>\n<li>Bollag, D.M., et al. (1996). Protein Methods. Second Edition. Wiley-Liss, Inc., New York.<\/li>\n<li>Einarson, M.B. and Orlinick, J.R. (2002). Identification of protein-protein interactions with glutathione-S-transferase fusion proteins. In Protein-Protein Interactions, Golemis, E., Ed., Cold Spring Harbor Laboratory Press pp.37-57.<\/li>\n<li>Gallagher, S. (1996). Immunoblot Detection. Current Protocols in Protein Science, pp. 10.10.1-10.10.11. John Wiley and Sons, Inc., New York.<\/li>\n<li>Gershoni, J. (1988). Protein blotting. Meth. Biochem. Anal. 33:1-58.<\/li>\n<li>Gershoni, J.M. and Palade, G.E. (1983). Protein blotting: principles and applications. Anal. Biochem. 131:1-15.<\/li>\n<li>Gershoni, J.M. and Palade, G.E. (1982). Electrophoretic transfer of proteins from sodium dodecyl sulfate-polyacrylamide gels to a positively charged membrane filter. Anal. Biochem. 124:396-405.<\/li>\n<li>Hall, R.A. (2004). Studying protein-protein interactions via blot overlay or far Western blot. In Protein-Protein Interactions, methods and Applications; Methods Mol. Biol. 261:167-74.<\/li>\n<li>Harlow, E. and Lane, D. (1988). Antibodies: A Laboratory Manual. Cold Spring Harbor Laboratory, Cold Spring Harbor, New York.<\/li>\n<li>Malik, V.S. and Lillehoj, E.P. (1994). Antibody Techniques. Academic Press, Inc., San Diego, CA.<\/li>\n<li>Ramlau, J. (1987). Use of secondary antibodies for visualization of bound primary reagents in blotting procedures. Electrophoresis 8:398-402.<\/li>\n<li>Spinola, S.M. and Cannon, J.G. (1985). Different blocking agents cause variation in the immunologic detection of proteins transferred to nitrocellulose membranes. J. Immunol. Meth. 81:161.<\/li>\n<li>Towbin, H. and Gordon, J. (1984). Immunoblotting and dot immunoblotting \u2013 Current status and outlook. J.Immunol. Meth. 72:313-40.<\/li>\n<li>Towbin, H., et al. (1979). Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications. Proc. Natl. Acad. Sci. USA 76:4350-4.<\/li>\n<li>Ursitti, J.A., et al. (1995). Electroblotting from Polyacrylamide Gels. Current Protocols in Protein Science, pp. 10.7.1-10.7.14. John Wiley and Sons, Inc., New York.<\/li>\n<li>Young, P.R. (1989) An improved method for the detection of peroxidase conjugated antibodies on immunoblots. J. Virol. Meth. 24:227-36.<\/li>\n<\/ul>\n<h1>\u3010\u7121\u6599\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3011\u30bf\u30f3\u30d1\u30af\u8cea\u89e3\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u30cf\u30f3\u30c9\u30d6\u30c3\u30af<\/h1>\n<p>\u52b9\u7387\u7684\u306a\u30bf\u30f3\u30d1\u30af\u8cea\u62bd\u51fa\u304b\u3089\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u89e3\u6790\u30c4\u30fc\u30eb\u307e\u3067\u3001\u5305\u62ec\u7684\u306b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u7d39\u4ecb\u3057\u3066\u304a\u308a\u307e\u3059\u3002PDF\u30d5\u30a1\u30a4\u30eb\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3092\u3054\u5e0c\u671b\u306e\u65b9\u306f\u3001\u4e0b\u8a18\u30dc\u30bf\u30f3\u3088\u308a\u304a\u7533\u8fbc\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n<p><a class=\"btn btn-red\" href=\"https:\/\/www.thermofisher.com\/jp\/ja\/home\/global\/forms\/catalogs-protein-form.html?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3059\u308b<\/a><\/p>\n<h2>\u30bf\u30f3\u30d1\u30af\u8cea\u306e\u691c\u51fa\u30fb\u89e3\u6790\u95a2\u9023\u3001\u305d\u306e\u4ed6\u306e\u8a18\u4e8b\u306f\u3053\u3061\u3089<\/h2>\n<table style=\"border-color: lightgray;border-collapse: collapse;padding: 20px\" border=\"1\">\n<tbody>\n<tr>\n<td style=\"border-color: lightgray;padding: 20px\">\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic10\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c10\u56de\u301110\u5206\u3067\u5206\u304b\u308b\u30d3\u30aa\u30c1\u30f3\u7d50\u5408\u30bf\u30f3\u30d1\u30af\u8cea\u307e\u3068\u3081\n<p><\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/protein-basic11\/?CID=bid_pca_wwg_r04_jp_cp0000_pjt0000_bid00000_0so_blg_op_awa_oc_s00_pa47_Social_LAB\" target=\"_blank\" rel=\"noopener\">\u3010\u7b2c11\u56de\u3011\u30d3\u30aa\u30c1\u30f3\u6a19\u8b58\u8a66\u85ac\u307e\u3068\u3081\n<p><\/a><\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>\u7814\u7a76\u7528\u306b\u306e\u307f\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002\u8a3a\u65ad\u7528\u306b\u306f\u4f7f\u7528\u3044\u305f\u3060\u3051\u307e\u305b\u3093\u3002<\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306f\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u540c\u5b9a\u3059\u308b\u305f\u3081\u306b\u5e83\u304f\u7528\u3044\u3089\u308c\u308b\u624b\u6cd5\u3067\u3042\u308a\u3001\u96fb\u6c17\u6cf3\u52d5\u3067\u5206\u96e2\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3057\u3066\u6297\u539f\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u624b\u6cd5\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u57fa\u672c\u539f\u7406\u3068\u5404\u8981\u56e0\u306b\u95a2\u3057\u3066\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":988,"featured_media":2519,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[156],"tags":[17],"division":[],"class_list":{"0":"post-325","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-mol-bio","8":"tag-western-blotting","9":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9 - Learning at the Bench<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/\" \/>\n<meta property=\"og:locale\" content=\"ja_JP\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9\" \/>\n<meta property=\"og:description\" content=\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306f\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u540c\u5b9a\u3059\u308b\u305f\u3081\u306b\u5e83\u304f\u7528\u3044\u3089\u308c\u308b\u624b\u6cd5\u3067\u3042\u308a\u3001\u96fb\u6c17\u6cf3\u52d5\u3067\u5206\u96e2\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3057\u3066\u6297\u539f\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u624b\u6cd5\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u57fa\u672c\u539f\u7406\u3068\u5404\u8981\u56e0\u306b\u95a2\u3057\u3066\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Learning at the Bench\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ThermoFisherJapan\" \/>\n<meta property=\"article:published_time\" content=\"2020-03-31T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-12T08:27:48+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"LATB Staff\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:site\" content=\"@ThermoFisherJP\" \/>\n<meta name=\"twitter:label1\" content=\"\u57f7\u7b46\u8005\" \/>\n\t<meta name=\"twitter:data1\" content=\"LATB Staff\" \/>\n\t<meta name=\"twitter:label2\" content=\"\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593\" \/>\n\t<meta name=\"twitter:data2\" content=\"44\u5206\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/\"},\"author\":{\"name\":\"LATB Staff\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"headline\":\"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9\",\"datePublished\":\"2020-03-31T15:00:00+00:00\",\"dateModified\":\"2025-08-12T08:27:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/\"},\"wordCount\":546,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/chemiluminescent-westernblotting-guide-title.png\",\"keywords\":[\"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\"],\"articleSection\":[\"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023\"],\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/\",\"name\":\"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9 - Learning at the Bench\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/chemiluminescent-westernblotting-guide-title.png\",\"datePublished\":\"2020-03-31T15:00:00+00:00\",\"dateModified\":\"2025-08-12T08:27:48+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#breadcrumb\"},\"inLanguage\":\"ja\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/chemiluminescent-westernblotting-guide-title.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/wp-content\\\/uploads\\\/sites\\\/13\\\/2019\\\/07\\\/chemiluminescent-westernblotting-guide-title.png\",\"width\":1200,\"height\":630,\"caption\":\"chemiluminescent-westernblotting-guide-title\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/learning-at-the-bench\\\/chemiluminescent-westernblotting-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/\",\"name\":\"Learning at the Bench\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ja\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/learning-at-the-bench\\\/#\\\/schema\\\/person\\\/00a095a01d54afcdf9457465feb04f7d\",\"name\":\"LATB Staff\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ja\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g\",\"caption\":\"LATB Staff\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/latbstaff\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9 - Learning at the Bench","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/","og_locale":"ja_JP","og_type":"article","og_title":"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9","og_description":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306f\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u540c\u5b9a\u3059\u308b\u305f\u3081\u306b\u5e83\u304f\u7528\u3044\u3089\u308c\u308b\u624b\u6cd5\u3067\u3042\u308a\u3001\u96fb\u6c17\u6cf3\u52d5\u3067\u5206\u96e2\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u30e1\u30f3\u30d6\u30ec\u30f3\u306b\u8ee2\u5199\u3057\u3066\u6297\u539f\u7279\u7570\u7684\u306b\u691c\u51fa\u3059\u308b\u624b\u6cd5\u3067\u3059\u3002\u4eca\u56de\u306f\u3001\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u306e\u57fa\u672c\u539f\u7406\u3068\u5404\u8981\u56e0\u306b\u95a2\u3057\u3066\u3054\u7d39\u4ecb\u3057\u3066\u3044\u304d\u307e\u3059\u3002","og_url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/","og_site_name":"Learning at the Bench","article_publisher":"https:\/\/www.facebook.com\/ThermoFisherJapan","article_published_time":"2020-03-31T15:00:00+00:00","article_modified_time":"2025-08-12T08:27:48+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title.png","type":"image\/png"}],"author":"LATB Staff","twitter_card":"summary_large_image","twitter_creator":"@ThermoFisherJP","twitter_site":"@ThermoFisherJP","twitter_misc":{"\u57f7\u7b46\u8005":"LATB Staff","\u63a8\u5b9a\u8aad\u307f\u53d6\u308a\u6642\u9593":"44\u5206"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/"},"author":{"name":"LATB Staff","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"headline":"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9","datePublished":"2020-03-31T15:00:00+00:00","dateModified":"2025-08-12T08:27:48+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/"},"wordCount":546,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title.png","keywords":["\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0"],"articleSection":["\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"],"inLanguage":"ja","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/","url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/","name":"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9 - Learning at the Bench","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title.png","datePublished":"2020-03-31T15:00:00+00:00","dateModified":"2025-08-12T08:27:48+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#breadcrumb"},"inLanguage":"ja","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/"]}]},{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title.png","width":1200,"height":630,"caption":"chemiluminescent-westernblotting-guide-title"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/chemiluminescent-westernblotting-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/"},{"@type":"ListItem","position":2,"name":"\u3053\u308c\u304c\u3042\u308c\u3070\u3082\u3046\u30ab\u30f3\u30da\u30ad\uff01\u5316\u5b66\u767a\u5149\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u5b8c\u5168\u30ac\u30a4\u30c9"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#website","url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/","name":"Learning at the Bench","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ja"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/#\/schema\/person\/00a095a01d54afcdf9457465feb04f7d","name":"LATB Staff","image":{"@type":"ImageObject","inLanguage":"ja","@id":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8803277856c8b753feb4217dff0f9953327452df1a615c3c88b2f9864efb2ddd?s=96&d=mm&r=g","caption":"LATB Staff"},"url":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"}]}},"taxonomy_info":{"category":[{"value":156,"label":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023"}],"post_tag":[{"value":17,"label":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title-1024x538.png",760,399,true],"author_info":{"display_name":"LATB Staff","author_link":"https:\/\/admin.acceleratingscience.com\/author\/latbstaff\/"},"comment_info":0,"category_info":[{"term_id":156,"name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","slug":"mol-bio","term_group":0,"term_taxonomy_id":156,"taxonomy":"category","description":"","parent":0,"count":538,"filter":"raw","meta":[],"cat_ID":156,"category_count":538,"category_description":"","cat_name":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","category_nicename":"mol-bio","category_parent":0}],"tag_info":[{"term_id":17,"name":"\u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0","slug":"western-blotting","term_group":0,"term_taxonomy_id":17,"taxonomy":"post_tag","description":"","parent":0,"count":27,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":24108,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/cell-culture-cell-count-bid-ts-mbr-25065-2\/","url_meta":{"origin":325,"position":0},"title":"\u3010\u7b2c6\u56de\u3011 \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c6\u30a3\u30f3\u30b0\u6cd5\u306b\u3088\u308b \u300e\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u4e2d\u306e\u30bf\u30f3\u30d1\u30af\u8cea\uff08Protein cargo\uff09\u300f\u306e\u89e3\u6790","author":"LatB Staff","date":"2026\u5e747\u670815\u65e5","format":false,"excerpt":"\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u306f\u3001\u7d30\u80de\u304b\u3089\u5206\u6ccc\u3055\u308c\u308b\u5c0f\u3055\u306a\u819c\u5c0f\u80de\u3067\u3001\u6838\u9178\uff08RNA\uff0fDNA\uff09\u3060\u3051\u3067\u306a\u304f\u3001\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2025\/11\/cell-culture-cell-count-bid-ts-mbr-25065_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":24606,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/transfection-antibody-bid-ts-mbr-26004\/","url_meta":{"origin":325,"position":1},"title":"\u7d30\u80de\u5185\u30bf\u30f3\u30d1\u30af\u8cea\u9664\u53bb\u30b7\u30b9\u30c6\u30e0\uff08Trim-Away\u6cd5\uff09\u306e\u7d39\u4ecb\uff5e\u30a8\u30ec\u30af\u30c8\u30ed\u30dd\u30ec\u30fc\u30b7\u30e7\u30f3\u6a5f\u5668\u3092\u4f7f\u7528\u3057\u3066\uff5e","author":"LatB Staff","date":"2026\u5e742\u67084\u65e5","format":false,"excerpt":"2018\u5e74\u306e\u6587\u732e(1)\u3067\u7d30\u80de\u5185\u306e\u5185\u5728\u6027\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u76f4\u63a5\u5206\u89e3\u3059\u308b\u3001Trim-Away\u6cd5\u304c\u7d39\u4ecb\u3055\u308c\u307e\u3057\u305f\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/01\/transfection-antibody-bid-ts-mbr-26004_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25565,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-antibody-ts-r-25068\/","url_meta":{"origin":325,"position":2},"title":"\u3010\u7b2c8\u56de\u3011\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u30b5\u30d6\u30bf\u30a4\u30d7\u306e\u5206\u753b\u6cd5 \uff1a \u30a6\u30a7\u30b9\u30bf\u30f3\u30d6\u30ed\u30c3\u30c8\uff0fqRT-PCR\uff0f\u30b7\u30fc\u30b1\u30f3\u30b9\u89e3\u6790\u306b\u9069\u3057\u305f\u5206\u753b\u65b9\u6cd5","author":"LatB Staff","date":"2026\u5e749\u670829\u65e5","format":false,"excerpt":"\u672c\u7a3f\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u819c\u4e0a\u306e\u7279\u5b9a\u306e\u30bf\u30f3\u30d1\u30af\u8cea\u3092\u6a19\u7684\u3068\u3057\u305f\u514d\u75ab\u5438\u7740\u6cd5\u306b\u57fa\u3065\u304f\u5206\u753b\u624b\u6cd5\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u30a8\u30af\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25019_eyecatch.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":25170,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/antibody-purification-vaccine-bpg-26018\/","url_meta":{"origin":325,"position":3},"title":"\u3010\u7c21\u5358\u89e3\u8aac\uff01\u3011\u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\u7cbe\u88fd\u306e\u57fa\u790e\u3068\u30a2\u30d5\u30a3\u30cb\u30c6\u30a3\u6a39\u8102\u9078\u629e","author":"LatB Staff","date":"2026\u5e745\u670819\u65e5","format":false,"excerpt":"\u5c0e\u5165 \u30d0\u30a4\u30b9\u30da\u30b7\u30d5\u30a3\u30c3\u30af\u6297\u4f53\uff08bispecific antibody\u3001\u4ee5\u4e0bBsAb\uff09\u306f\u30012\u3064\u306e\u7570\u306a\u308b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/04\/antibody-purification-vaccine-bpg-26018_eyecatch.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25325,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25019\/","url_meta":{"origin":325,"position":4},"title":"\u3010\u7b2c5\u56de\u3011 &#8220;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\u300d\uff5emRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e746\u670811\u65e5","format":false,"excerpt":"\u4eca\u56de\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09\u4e2d\u306emRNA\u306e\u5b9a\u91cf\u89e3\u6790\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3067\u30a8\u30af\u30bd\u30bd\u30fc\u30e0\u304b\u2026","rel":"","context":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","block_context":{"text":"\u5206\u5b50\u751f\u7269\u5b66\u5b9f\u9a13\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/mol-bio\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":25247,"url":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/exosome-gene-expression-ts-r-25018\/","url_meta":{"origin":325,"position":5},"title":"\u3010\u7b2c4\u56de\u3011&#8221;RNA cargo&#8221;\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff5emiRNA\u306e\u5b9a\u91cf\u89e3\u6790\uff5e","author":"LatB Staff","date":"2026\u5e745\u670829\u65e5","format":false,"excerpt":"\u524d\u56de\uff08\u3010\u7b2c3\u56de\u3011\u201cRNA cargo\u201d\u306e\u7cbe\u88fd\u3068\u5b9a\u91cf\u89e3\u6790\uff09\u3067\u306f\u3001\u30a8\u30af\u30bd\u30bd\u30fc\u30e0 \uff08\u30a8\u30ad\u30bd\u30bd\u30fc\u30e0\uff09 \u304b\u3089\u306e\u2026","rel":"","context":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","block_context":{"text":"\u5206\u6790\u30fb\u6e2c\u5b9a\u95a2\u9023","link":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/analysis\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2026\/05\/exosome-gene-expression-ts-r-25018_eyecatch-1.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"amp_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/learning-at-the-bench\/wp-content\/uploads\/sites\/13\/2019\/07\/chemiluminescent-westernblotting-guide-title.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/users\/988"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/comments?post=325"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/posts\/325\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media\/2519"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/media?parent=325"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/categories?post=325"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/tags?post=325"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/learning-at-the-bench\/wp-json\/wp\/v2\/division?post=325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}